|
| 1 | Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded with 15x3 mm lugs 10cm long embedded in cement concrete blocks 15x10x10 cm of 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggre |
| 2 | Repair of door, window shutters including cost of material and labour for change of damaged : |
| 3 | Style / rail of teak wood 30mm thick/ Aluminium Section |
| 4 | 4\\"wide |
| 5 | Providing & fixing UV stabilised fiberglass reinforced plastic sheet roofing upto any pitch including fixing with polymer coated ‘J’ or ‘L’ hooks, bolts & nuts 8mm dia. G.I plain/bitumen washers complete but excluding the cost of purlins, rafters, trusses |
| 6 | 3.0mm thick (Wt. 5.0 Kg./Mtr. Sq.) |
| 7 | Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead and including a coat o |
| 8 | 1.00 mm thick with zinc coating not less than 275 gm/m2 |
| 9 | Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. |
| 10 | 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size). |
| 11 | Random Rubble stone masonry for with hard stone in foundation and plinth in Cement Sand mortar above 30 CM thick wall in: |
| 12 | Cement Mortar 1:6 ( 1-Cement : 6-Sand). |
| 13 | Brick work with F.P.S. bricks of class designation 75 in superstructure above plinth level upto floor V level in all shapes and sizes in : |
| 14 | Cement mortar 1 : 6 (1 cement : 6 coarse sand) |
| 15 | Half brick masonry in Superstructure , above plinth level upto floor V level using bricks of designation 75 |
| 16 | Cement mortar 1 : 4 (1 cement : 4 coarse sand) |
| 17 | Plaster on new surface on walls in cement sand mortar 1:6 including racking of joint etc. complete fine finish : |
| 18 | 20mm thick. |
| 19 | Providing and fixing steel glazed doors windows and ventilator shutters of standard rolled steel section (IS 1038-1983) joints mitred and welded with steel lugs 13x3mm, 10cm. long embedded in cement concrete block 15x10x10cm. of 1:3:6 (1cement : 3 coarse |
| 20 | Windows side hung /Ventilators top or centre hung (openable) |
| 21 | Supplying and fixing fixed wire gauge of 14 mesh x 24 gauge to the metal frame of rolled section by metal beading 20x3mm with suitable screw at not exceeding 150mm distance. |
| 22 | Providing and fixing Square bars or other flat welded to window, ventilatiors etc. |
| 23 | Providing and fixing 1mm thick M.S. sheet garrage door shutters with frame of 40 x 40 x 6mm. angle iron 3mm M.S. gusset plates at the junction and corners including all fittings and applying a coat of approved steel primer : (Excluding cost of frames) |
| 24 | Using flats 30 x 6mm for diagonal braces and central cross piece. |
| 25 | Providing and fixing external grade board solid core single leaf flush door shutters ISI 2202-67 marked using Phenol formal dehyderesin in glue both sides with approved steel fittings complete as per annexure 'A' : |
| 26 | 25 mm thick . |
| 27 | Decorative teak veneer One side |
| 28 | Providing and fixing 1st quality standard white, grey, ivory, fume red brown, light green, light blue and other light shades glazed tiles confirming to IS : 13753 & IS :15622 of size 200mm x 300mm in walls, floors, steps, pillars etc. laid on a bed of nea |
| 29 | Providing and fixing 1st quality MAT finished ceremic tile size 300x300mm confirming to IS : 13755 and IS : 15622 colour such as white, grey, ivory, fume red brown, light green, light blue and other light shades in floors, steps, pillars etc. laid on a b |
| 30 | P & F 1st qualityHeavy Duty Vitrified Polished Digital tiles on floor, skirting and steps etc.in different sizes (thickness minimum 10mm) with water absortion less than or equal 0.08% and conforming to IS 15622 of approved make in all colour and shade, la |
| 31 | Size 300mm x 450mm |
| 32 | P & F 1st qualityVitrified Porcelain Polished tiles on floor, skirting and steps etc.in different sizes (thickness to be specified by manufactuer) with water absortion less than 0.08% and conforming to IS 15622 of approved make in all colour and shade, l |
| 33 | size 600 mm X 600 mm |
| 34 | Grading roof for water proofing treatment with water proffing compound |
| 35 | Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) |
| 36 | Providing and Applying ACRYLIC emulsion polymer waterproofing chemical coating, on over roof on over roof slabs/terrace/balconies/parapet wall etc.with following method/specification:Paint the surface with regular paint brush so as to obtain approximately 0.3mm thickness coating. apply the 2nd coat next day at right angles to the 1st coat so that total thickness of the coating should be approximately 0.6mm coverage by using above formulation will be 40 ft2/ litre of chemical. painted surface does not require any external water curing since chemical will hold sufficient water for curing.After the primer coat Apply 2 coats of modified acrylic emulsion polymer water proofing compound having solar heat reduction properties coating @ 0.330 KG/SQM on the surface of the interval of 3-4 hours. Undulation on the surface is repair before the waterproofing work. |
| 37 | Providing and fixing Granite stone slab mirror polished and machine edge cut in walls, pillars, steps, Shelves, Sills Counters, Floors etc. laid on 12mm (Av.) thick base of cement mortar 1:3 (1 cement : 3 coarse sand) jointing with white cement mortar 1:2 |
| 38 | Jhunjhunu / Jalore (Red/Choclate/Black/Pink Colour) |
| 39 | Above 3601 Cm2 Slabs |
| 40 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry, making of lines or groove etc complete but excluding the cost of nosing of steps etc. complete. |
| 41 | 75mm thick with 20mm thick nominal size aggregate. |
| 42 | Providing and laying of paver block as per IS 15658 : 2006 (Indian standard for precast concrete block for paving- specification) and IRC : SP:63-2004 (guidelines for the use of interlocking concrete block pavement) |
| 43 | M-30, 60 mm thick to be used in non traffic areas like building premises, monument premises, land scapes, public gardens/ park, domestic drives, paths and patios, Embankment slopes, sand stabilization Area etc.( As per table 1 of IS 15658:2006 |
| 44 | Category A Denated units to key into each other on four faces zigzag shape as per IRC SP 63:2004 |
| 45 | Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. |
| 46 | 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40mm nominal size). |
| 47 | Providing and applying white cement based putty over plastered surface to prepare the surface even and smooth complete |
| 48 | New Plastered Surface (three or more coats) |
| 49 | Providing and applying white cement based putty over plastered surface to prepare the surface even and smooth complete |
| 50 | Old Plastered Surface (two or more coats) |
| 51 | Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade including all scaffolding: |
| 52 | Old work (One or more coats ) |
| 53 | Distempering with 1st quality acrylic washable distemper (ready mixed) of approved manufacturer and of required shade and colour completeincluding all scaffolding as per manufacturer's specification. Two or more coats on new work including prepartion of |
| 54 | Finishing wall with water proofing cement paint of approved brand and manufacture and or required shade to give an even shade including all scaffolding: |
| 55 | Old work (One or more coats). |
| 56 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : |
| 57 | One or more coats on old work. |
| 58 | Providing and fixing steel gate, grating , and grills made of angles, tees, square bars, flats,or black pipe with holdfast and fittings complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide |
| 59 | Providing and fixing Polyethylene - Aluminium -Polyethylene (PE-AL-PE) Composite Pressure Pipes as per 15450 : 2004 U.V. stablised with carbon black having thermal stabillity for hot and cold water supply, capable to withstand temperature upto 80ºC includ |
| 60 | 1216 (16mm OD) pipe |
| 61 | Providing and fixing Polyethylene - Aluminium -Polyethylene (PE-AL-PE) Composite Pressure Pipes as per 15450 : 2004 U.V. stablised with carbon black having thermal stabillity for hot and cold water supply, capable to withstand temperature upto 80ºC includ |
| 62 | 2025 (25mm OD) pipe |
| 63 | P&F rigid PVC pipe fittings (IS: 4985 mark) of approved quality /make including joining the pipe with solvent cement rubber ring and lubricant: |
| 64 | Bend 87 .5 |
| 65 | 110mm dia |
| 66 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes (IS 15778 : 2007 code) having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1 metre spacing. This includ |
| 67 | 25 mm nominal size |
| 68 | P&F rigid PVC pipe fittings (IS: 4985 mark) of approved quality /make including joining the pipe with solvent cement rubber ring and lubricant: |
| 69 | Pipe Clip |
| 70 | 110mm dia |
| 71 | P & F Indian type white glazed vitreous china 1st quality W.C. orissa pan (IS :2556 Mark) with 100 mm vitreous china P or S trap including cutting and making good the wall and floor: |
| 72 | Size 530x410mm. |
| 73 | P & F European type white glazed vitreous china 1st quality W.C pan (IS : 2556 Mark) with P or S trap including cutting and making good the wall and floor |
| 74 | P & F Jet spray for water closet with C.P. Copper Tube flange of approved make. |
| 75 | P & F WVC Wash basin (Ist quality IS:2556 Mark) of approved make with C.I. brackets duly painted 1 No. 15 mm C.P. Pillar cock (IS:8934 Mark) & 32 mm C.P. brass waste coupling of approved make, P.V.C Waste pipe with PVC nut 32 mm complete including cutti |
| 76 | Size 450 mm x 300 mm |
| 77 | P & F Kitchen & Lab. Sink of approved make with C.I. brackets duly painted, 40 mm C.P. waste coupling, C.P. Brass chain with rubber plug, 40 mm G.I. waste pipe up-to floor level complete including cutting and making good the wall & floor : |
| 78 | Fire clay glazed kitchen sink (I.S 771-1985 Marked) size 600 x 450 x 250mm. |
| 79 | P & F Inlet Connection (Angle Valves) Superior quality, of approved make, for Wash basin, Gyser etc. |
| 80 | C.P. Inlet connection 15mm.Brass (IS : 8931 marked) |
| 81 | P & F Low level Flushing Cistern of 10 litres capacity (IS : 2556 mark) of approved make with complete fittings C.I. brackets duly painted, brass ball cock with ball (IS: 1703 mark) complete including cutting and making good the wall: |
| 82 | PVC with PVC bend as per IS : 7231 . |
| 83 | P & F Bib Cock (IS : 8931 Mark), Superior quality of approved make: |
| 84 | C.P. Brass bib cock,15mm nominal bore. |
| 85 | P&F rigid PVC pipe fittings (IS: 4985 mark) of approved quality /make including joining the pipe with solvent cement rubber ring and lubricant: |
| 86 | Door Tee |
| 87 | 110mm dia |
| 88 | P & F 15 mm. Dia Connection Pipe of approved quality/make : |
| 89 | (-do-) 450mm. |
| 90 | P & F water closet Seat Covers with brass hinges complete : |
| 91 | Solid PVC (IS 2548 marked) grade-I Black for EWC. |
| 92 | P & F Full-way Valve (IS:778 Mark) or wheel valve of approved make : |
| 93 | Gun-metal 15mm nominal bore. |
| 94 | P & F Full-way Valve (IS:778 Mark) or wheel valve of approved make : |
| 95 | (-do-) 25mm nominal bore. |
| 96 | P & F Ball Cock (IS :1703 Mark) with Rod & P.V.C. Ball complete : |
| 97 | Brass wt. Not less than 300 gm,15mm. |
| 98 | P & F PVC Storage Tank ISI Marked (IS : 12701) indicating the BIS license No), of approved make with cover, 25mm dia 1M long G.I. over-flow pipe & 25 Cm. long wash out pipe with plug & socket, including making connection etc., complete of approved desig |
| 99 | 500 (-do-) |
| 100 | P & F Looking Mirrors with P.V.C. frame of approved make as per direction of Engineer-in-charge |
| 101 | Size 500x400mm |
| 102 | Providing and fixing S.S. Rod 30mm dia (304 grade ,16SWG) including brackets fixed with C.P. brass screws and rawl plugs, etc., wherever necessary complete two side central all fittings. |
| 103 | P & F Soap Dish or Tray of approved quality/make |
| 104 | WVC (1st Quality, IS 2556 Marked) recessed size 150 x 150 mm. |
| 105 | P & F Towel Rail or Ring of approved quality/make: |
| 106 | C.P. brass Towel Rail elbow type with concealed screws size 450mm (Heavy duty). |
| 107 | P & F Bevelled edge Mirror/mirror with teak wood lipping around of special glass of approved make as per direction of Engineer-in-charge complete with 6mm thick commercial ply base fixed to wooden screws & washers. |
| 108 | Size 600 x 450mm x 4 mm thick Please Enable Macros to View BoQ information |