| 1 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth, 1.5m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed. |
| 2 | Filling available excavated earth (excluding rock) intrenches, plinth, sides of foundations etc. in layers notexceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.-All kinds of soil |
| 3 | Supplying and filling in plinth, under floor, foundations etc. with sand (fine) from local quarry with all lifts including spreading in horizontal layers, watering, grading to required slope, ramming, consolidating and compacting each layer by using plate compactor or by any suitable method complete. |
| 4 | Providing and laying in position cement concrete ofspecified grade excluding the cost of centring andshuttering --All work upto plinth level:1:4:8 ( 1 Cement: 4 fine sand : 8 graded stone aggregate40 mm nominal size) |
| 5 | Making plinth protection 50mm thick of cementconcrete 1:3:6 (1 cement : 3 fine sand : 6 graded wellburnt brick aggregate 20 mm nominal size) over75mm bed of dry brick ballast 40mm nominal sizewell rammed and consolidated and grouted with finesand including finishing the top smooth. |
| 6 | Providing and laying in position specified grade ofreinforced cement concrete excluding the cost ofcentring, shuttering, finishing and reinforcement--All work upto plinth level:1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stoneaggregate 20 mm nominal size) |
| 7 | Reinforced cement concrete work in walls (anythickness), including attached pilasters, buttresses,plinth and skirting courses, fillets, columns, pillars,piers, abutments, posts and struts etc. upto floor fivelevel excluding cost of centring, shuttering, finishingand reinforcement-1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stoneaggregate 20 mm nominal size) |
| 8 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto floor five levelexcluding the cost of centring, shuttering, finishing andreinforcement-1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stoneaggregate 20 mm nominal size) |
| 9 | Reinforcement for R.C.C. work including straightening,cutting, bending, placing in position and binding allcomplete upto plinth level. |
| 10 | Centering shuttering including struttings, propping etc. and removal of form work for: |
| 11 | Foundations, footings, bases for columns etc. for massconcrete with timber plank |
| 12 | Suspended floors, roofs, landings, balconies and access platform with 12 mm thick shuttering ply |
| 13 | Lintels, beams, plinth beams, girders, bressumers andcantilevers with shuttering ply |
| 14 | Columns, Pillars, Piers, Abutments, Posts and Struts with shuttering ply |
| 15 | First class brick work in foundation and plinthincluding cost of all materials as required complete:-In cement mortar 1:6 ( 1 cement : 6 fine sand ). |
| 16 | First class brick work in superstructure above plinthlevel & upto floor-five level including cost of allmaterials as required complete:- |
| 17 | Providing and fixing M.S. grills of required pattern inframes of windows etc. with M.S. flats, square orround bars etc. all complete.Fixed to openings /wooden frames with rawl plugsscrews etc. |
| 18 | Providing and laying 1st class quality ceramic floor tilesin different sizes (thickness to be specified by themanufacturer) of 1st quality conforming to IS : 15622 -2017 of approved make in colours such as White, Ivory,Grey, Fume Red Brown, laid over 20 mm thick cementmortar 1:4 (1 cement : 4 fine sand), Jointing with greycement slurry @ 3.3 kg/sqm including pointing the jointswith white cement and matching pigment etc. allcomplete as per direction of the Engineer in-charge.Mat Finish Tiles/ Anti-skid Tiles/ Glossy Tiles 300 mm x 300 mm in all shades and designs |
| 19 | 12 mm cement plaster of mixCement mortar 1:6 (1 cement : 6 fine sand) |
| 20 | 15 mm cement plaster on the rough side of single or halfbrick wall of mix:Cement mortar 1:4 (1 cement : 4 fine sand) |
| 21 | Neat cement punning. |
| 22 | Providing and fixing 1mm thick M.S. sheet door withframe of 40x40x6mm angle iron and 3mm M.S. gussetplates at the junctions and corners, & with cleats withbolts & nuts, rivets, locking arrangement, handles, hooks & eyes, pinlets including embedding in cement concrete of required grade for fixing in position, all necessary fittings, including applying a priming coat of approved steel primer etc. complete as required:- |
| 23 | Distempering with 1st quality acrylic distemper (readymixed) having VOC content less than 50 grams/ litre, ofapproved brand and manufacture to give an even shade[Payment shall be made after submission of TestCertificate issued by the Manufacturer] :New work ( two or more coats) over and including waterthinnable priming coat with cement primer. |
| 24 | Finishing walls with premium acrylic smooth exteriorpaint with Silicon additives of required shade ofapproved brand and manufacture [Payment shall bemade after submission of Test Certificate issued by theManufacturer] :New work ( two or more coats applied @ 1.43 litre/10 sqmover and including priming coat of exterior primer applied@ 2.20 kg/10 sqm) |
| 25 | Painting with synthetic enamel paint ( one or morecoats ) of required colour of approved brand andmanufacture on old work to give an even shadeincluding preparation of surface as required completeas per direction of the Engineer in charge. |
| 26 | Supply & installation of pre-painted Galvalume sheetsfor roofing/cladding (size, shape and pitch ofcorrugation as approved by Engineer-in-charge) in550mpa steel grade, made out of Cold Rolled Steelcoated with Zinc-Aluminium alloy coating of 43.5% Zn,55% Al and 1.5% Silicon confirming to ASTMA792/A792M and AS1397, Alloy coating AZ150/AZ70,colour coated with high quality Polyester coating, topcoated of modified polyester of 20 micron, back sidecoat of 5 micron, having epoxy primer coat of 5 micronon both side. Sheet should have protective guard filmof 25 microns minimum to avoid scratches whiletransportation and should be supplied in singlelength upto 12 metre or as desired by Engineer-incharge.The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55mm) with EPDMwashers filled with white lead complete upto anypitch in horizontal/ vertical or curved surfacesexcluding the cost of purlins, rafters and trusses andincluding cutting to size and shape wherever requiredand as per direction of Engineer-in-charge.0.50mm thickness |
| 27 | Steel work in built up tubular (round, square orrectangular hollow tubes etc.) trusses etc., includingcutting, hoisting, fixing in position and applying apriming coat of approved steel primer, including weldingand bolted with special shaped washers etc. complete.Hot finished welded type tubes |
| 28 | Providing and fixing flat pressed 3 layer mediumdensity particle board or graded particle board (Grade I)IS: 3087 marked in ceiling with necessary nails etc.complete as per direction of Engineer-in-charge. (framework to be paid separately):12 mm thick |
| 29 | Providing wood work in frames of false ceiling,partitions etc. sawn and put up in position :Local Teak Wood |
| 30 | Providing and fixing white vitreous china pedestaltype water closet (European type) with seat and lid, 10litre low level white vitreous china flushing cistern &C.P. flush bend with fittings & C.I.brackets, 40mmflush bend, overflow arrangement with specials ofstandard make and mosquito proof coupling ofapproved municipal design complete includingpainting of fittings and brackets, cutting and makinggood the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid. |
| 31 | Providing and fixing wash basin with C.I. brackets, 15mm C.P. brass pillar taps,32 mm C.P. brass waste ofstandard pattern, including painting of fittings andbrackets, cutting and making good the wallswherever require :White Vitreous China Wash basin size 630x450 mm with asingle 15 mm C.P. brass pillar taps. |
| 32 | Providing and fixing Chlorinated PolyvinylChloride (CPVC) pipes, having thermal stability forhot & cold water supply including all CPVC plain &brass threaded fittings including fixing the pipe withclamps at 1.00 m spacing. This includes jointing ofpipes & fittings with one step CPVC solvent cementand testing of joints complete as per direction ofEngineer in Charge.Internal work - Exposed on wall |
| 33 | 40 mm nominal outer dia .Pipes. |
| 34 | 25 mm nominal outer dia .Pipes. |
| 35 | 20 mm nominal outer dia .Pipes. |
| 36 | Providing and fixing C.P. brass bib cock of approvedquality conforming to IS:8931 15 mm nominal bore |
| 37 | Providing and fixing on wall face unplasticisedRigid PVC rain water pipes (working pressure 4kg/cm2) conforming to IS : 13592 Type A includingjointing with seal ring conforming to IS : 5382leaving 10 mm gap for thermal expansion etc.complete as per direction of Engineer-in-charge : |
| 38 | Single socketed pipe - 75 mm OD |
| 39 | Single socketed pipe - 110 mm OD |
| 40 | Providing and placing on terrace (at all floor levels)polyethylene water storage tank ISI : 12701 markedwith cover and suitable locking arrangement andmaking necessary holes for inlet, outlet and overflowpipes but without fittings and the base support fortank. |
| 41 | Constructing brick masonry chamber forunderground C.I. inspection chamber and bendswith 1st class bricks in cement mortar 1:4 (1cement : 4 fine sand) C.I. cover with frame (lightduty) 455x610 mm internal dimensions, totalweight of cover with frame to be not less than38 kg (weight of cover 23 kg and weight offrame 15 kg) R.C.C. top slab with 1:2:4 mix (1cement :2 fine sand : 4 graded stone aggregate20 mm nominal size) foundation concrete 1:5:10(1 cement: 5 fine sand : 10 graded stoneaggregate 40 mm nominal size), inside plastering12 mm thick with cement mortar 1:3 (1 cement:3 fine sand) finished smooth with a floating coatof neat cement on walls and bed concrete etc.complete as per standard design :Inside dimensions 500x700 mm and 45 cm deepfor pipe line with one or two inlets : Please Enable Macros to View BoQ information |