| 1 | Electrification |
| 2 | 1.10.3:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVCinsulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLSPVC insulated copper conductor single core cable etc as required.Group C |
| 3 | OD200197/2025-2026:Wiring combined plug point together with the light point/ fan point/ exhaust fan point/ call bell point including 6 A 5 pin modular socket controlled by 6A one way modular switch in the existing switch board and giving connection to the phase,neutral and earth terminal with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable ( Green wire for earthing) etc as required. |
| 4 | 1.33:Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. |
| 5 | OD200204/2025-2026:Supply, conveyance, installation, testing and commissioning of cast aluminium stove enameled elliptical shaped bulk head fittings directly on wall including cutting necessary holes, giving connections with the extended orginal wiring, making good the damgaes, colour washing etc as required. |
| 6 | 1.58:Supplying and fixing PVC batten/ angle holder including connection etc. as required. |
| 7 | OD200205/2025-2026:Supply and providing the 9W LED lamp in the existing fittings as required |
| 8 | 90.3.21.3:Supply & installation of light fittings on 'C/U' shaped flat iron bracket Supply, conveyance, installation, testing and commissioning the light fittings of following types made from 0.5mm CRCA sheet complete with all accessories and lamps etc. directly on wall using 2 nos. 'C/U' brackets made from 20 x 3 mm MS flat, painting the flat iron bracket and giving connections with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connection etc. as required.1200 mm 1X20W LED Lamp with box type fixture |
| 9 | 90.15.4.5:Supply Conveyance, installation, testing and commissioning of 40W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) |
| 10 | OD200216/2025-2026:Supply, Conveyance, Installation, Testing and commissioning of 3.7 KW/5 HP ,Three phase centrifugal Monoblock Pump Motor Model KDI 527 Suc 80mm xDel 65mm with castiron impeller ,SS Shaft and Mechanical seal suitable for 16 to 27 mtr head and 14.3 to 7.6 LPS discharge respectively at 20 mtr Head discharge will be 12.5 LPS =45,000 as per IS specification as required. (Kirloskar or Equalent)) |
| 11 | 90.14.28.2:S & F Motor starters of the following ratingsThree phase DOL starters for 0.25HP to 7.5 HP motor |
| 12 | 90.14.24.17:Supply & fixing the following Power Capacitors 3 phase delta connected in positon and giving connection.2 KVAr, 3 phase, 440 V, delta connected, standard duty Metalised Poly Propylene Capacitor, Box Type, suitable for direct connection to motors. |
| 13 | 90.14.1.1:Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623.Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc.Supply and fabrication of MV panel board using 2.00mm CRCA sheet, powder coated (excluding base frame) |
| 14 | OD200208/2025-2026:Supply and Installation of current Sensing Phase Failure & UV+OV relay with Dry run & Over load Protection (Delayed Auto reset, 2 CO Contact) on DIN rail (model:Minilec D2 MPR2) |
| 15 | OD200218/2025-2026:Supply and fixing of Multi function meter to read:W, Wh or VA, Vah or V AR, V ARh or PF - 3 phase accuracy class 1 LED include 3 nos CT |
| 16 | OD200223/2025-2026:Providing and fixing Blue colour LED indicator, AC/DC, 22.5 mm cut out dia in existing panel and giving connection complete |
| 17 | OD200212/2025-2026:Providing and fixing Red, Green, Black, Yellow, Orange colours LED indicator, AC/DC, 22.5 mm cut out dia in existing panel and giving connection complete |
| 18 | OD201775/2025-2026:Supply and Installation 63 MM Foot Valve Brass |
| 19 | OD200211/2025-2026:Supply and Installation 80mmx63mm Reducer |
| 20 | OD200226/2025-2026:Supply and Installation 63mm Green Hose Pipe |
| 21 | OD200207/2025-2026:Supply and Installation 63mm Union GI (ISI) |
| 22 | OD200228/2025-2026:Supply and Installation of 63mm GI Bend (ISI) |
| 23 | OD200217/2025-2026:Supply and Installation of 63mm GI Socket (ISI) |
| 24 | OD200225/2025-2026:Supply and Installation of 63mm non return valve(LMR) |
| 25 | OD200214/2025-2026:Supply and Installation of 63mmx1Feet G.I.Barrel nipple |
| 26 | OD200227/2025-2026:Supply and Installation of 63mm SS Hose coller LMR |
| 27 | OD200224/2025-2026:Supply and Installation of 63mm PVC TEE |
| 28 | OD200215/2025-2026:Supply and Installation of 63mm Ball Valve Appax Din |
| 29 | OD200220/2025-2026:Supply and Installation of 63mm HDPE ISI 6kg/cm2 pipe (Jain make LMR) |
| 30 | OD200229/2025-2026:Supply and Installation of 63mm HD Hose clip ss |
| 31 | OD200213/2025-2026:Supply and Installation 63mm MTA PVC(ISI) |
| 32 | OD200219/2025-2026:Supply and Installation 63mm PVC Pipe( ISI). |
| 33 | OD200222/2025-2026:25 mm Corrugated PVC flexible conduit |
| 34 | OD200198/2025-2026:Supply and providing shellac |
| 35 | OD200202/2025-2026:Supply & application of teflone tap (Thread seal tap) |
| 36 | OD200200/2025-2026:Supply and application of solvent cement |
| 37 | 90.11.1.14:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43) |
| 38 | 2.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Single pole |
| 39 | 2.10.4:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Triple pole |
| 40 | 2.13.1:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps |
| 41 | 2.15.2:Supplying and fixing following rating, four pole, (three phase and neutral), 415volts, residual current circuit breaker (RCCB), having a sensitivity current 30milli Amperes in the existing MCB DB complete with connections, testing andcommissioning etc. as required.40 amps |
| 42 | 2.11:Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 43 | 1.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm |
| 44 | 1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm |
| 45 | 1.17.21:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm |
| 46 | 1.17.24:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 4 sq. mm |
| 47 | 1.21.2:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm |
| 48 | 5.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 49 | 90.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG) |
| 50 | 90.16.5.1:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.00 mm (14 SWG) |
| 51 | 90.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG) |
| 52 | 90.16.5.2:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.65 mm (12 SWG) |
| 53 | OD200203/2025-2026:Supply and fixing 32A HRC Fuse with HRC fuse link with connections, in existing meter board |
| 54 | OD200206/2025-2026:Supply and fixing 32A,2 way neutral links mounted on DMC/SMC base with connections, in existing meter board |
| 55 | OD200201/2025-2026:Supply and providing and fixing 32A TPN disconnector fuse switch unit in sheet steel enclosure with ISI marked HRC fuses front handle on wall/angle iron frame including drilling holes in frame, making connections, etc. as required |
| 56 | OD200221/2025-2026:Supply &Installation of dust and vermin proof, 3 Phase Sintex meter board {GS MB6545) / Equivalent make of size 650x450x250 suitable for fixing KSEB meter,fuse units, CT etc, hinged door construction for the front side with compartments if necessary, providing vision panel for the meter compartment, knock out for cable entry and exit. |
| 57 | OD200199/2025-2026:Suppy and providing M8 anchor bolt hook in wall/parapet for binding support for service main |
| 58 | 90.14.5:Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board Please Enable Macros to View BoQ information |