| 1 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed. |
| 2 | M&L for Fe 410-W (Gde E-250 quality A) Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats, bolts, welding, engraving in beams and making it good etc complete all as specified and directed. |
| 3 | S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws as specified including dismantling of old asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings complete all as specified and directed. |
| 4 | S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws as including dismantling of old asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings complete all as specified and directed. |
| 5 | S&F Hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed. |
| 6 | M&L Modular Brick work with Fly Ash bricks straight or curved on plan exc 6m mean radius built in CM 1:6 incl demolition of old brick work or stone/ boulder masonary built in cement mortar including all quions, arches, pillars, etc complete all as specified and directed. |
| 7 | M&L Rendering on fair faces of brick work or concrete surfaces of wall 15 mm thick in CM 1:6 and to be finished even and smooth without using extra cement complete all as specified and directed. |
| 8 | Material & Labour for applying two or more coats of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm over new surfaces complete all as specified and directed. |
| 9 | M&L for PCC 1:2:4 type B1 using 20 mm graded stone aggregate as in lintels upto 1.5 m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like, landings, chajjas, shelves and similar articles with plain faces including chamfered, weathering, throating etc. and set in cement mortar (1:4) slightly rounded or chamfered angles complete all as specified and directed. |
| 10 | M&L for Erection, Fabrication & Refixing of old Fe 410-W (Gde E-250 quality A) Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats, bolts, welding, engraving in beams and making it good etc complete all as specified and directed. |
| 11 | M&L for Removing old paints by paint removes or burning off by blow lamps and cleaning with scrapers, any number of coats, any width or girth of old steel surfaces of any description, over 10 cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 12 | Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings,heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories) |
| 13 | S&F U-shaped UPVC Rainwater Gutter Pipe 3 mm thick (4Kg/sqcm gauge) 160 mm width and 100 mm depth with added rib of flow capacity 16 Litres/meter of colour as approved including necessary screws, cleats etc complete all as specified and directed. |
| 14 | S&F U-shaped UPVC Rainwater Gutter Centre Joint (Coupling) 3 mm thick (4Kg/sqcm gauge) 160 mm width and 100 mm depth of length 80 mm with added rib of colour as approved including necessary screws, cleats etc complete all as specified and directed. |
| 15 | S&F U-shaped UPVC Rainwater Gutter Centre Drop 3 mm thick (4Kg/sqcm gauge) 160 mm width and 100 mm depth of length 230 mm with outlet 90 mm dia (round outlet) of colour as approved including necessary screws, cleats etc complete all as specified and directed. |
| 16 | S&F U-shaped UPVC Rainwater Gutter End Drop 3 mm thick (4Kg/sqcm gauge) 160 mm width and 100 mm depth of length 192 mm with outlet 90 mm dia (round outlet) of colour as approved including necessary screws, cleats etc complete all as specified and directed. |
| 17 | S&F U-shaped UPVC Rainwater Gutter Clamp with GI extension with slope adjustment 3 mm thick (4Kg/sqcm gauge) 160 mm width and 100 mm depth of colour as approved including necessary screws, cleats etc complete all as specified and directed. (Note : Maximum spacing between two clamps should not exceed 1 metre.) |
| 18 | S&F U-shaped UPVC Rainwater Gutter End Cap 3 mm thick (4Kg/sqcm gauge) 160 mm width and 100 mm depth and of length 43 mm of colour as approved including necessary screws, cleats etc complete all as specified and directed. |
| 19 | S&F UPVC Rainwater Gutter 90 mm Round x 75 mm Square adopter of 92 mm length 3 mm thick (4Kg/sqcm gauge) with added rib of colour as approved using solvent cement to stick including necessary screws, cleats etc complete all as specified and directed. |
| 20 | S&F UPVC Rainwater Gutter Pipe of 75 mm Square size 3 mm thick (4Kg/sqcm gauge) with added rib of colour as approved using solvent cement to stick including necessary screws, cleats etc complete all as specified and directed. |
| 21 | S&F UPVC Rainwater Gutter Clamp 75 mm (sides) x 77 mm (depth) x 18 mm (width) 3 mm thick (4Kg/sqcm gauge) drilled and plugged into wall/ column and screwed of colour as approved including necessary screws, cleats etc complete all as specified and directed. (Note : Maximum spacing between two clamps should not exceed 1 metre.) |
| 22 | S&F 75 mm size UPVC Rainwater Gutter Centre Joint (Coupling) 3 mm thick (4Kg/sqcm gauge) of length 148 mm with added rib of colour as approved including necessary screws, cleats etc complete all as specified and directed. |
| 23 | S&F 75 mm size UPVC Rainwater Gutter Elbow 3 mm thick (4Kg/sqcm gauge) of length 148 mm inclination of 45 degree with added rib of colour as approved including necessary screws, cleats etc complete all as specified and directed. |
| 24 | S&F 75 mm size UPVC Rainwater Gutter Elbow 3 mm thick (4Kg/sqcm gauge) of length 148 mm inclination of 90 degree with added rib of colour as approved including necessary screws, cleats etc complete all as specified and directed. |
| 25 | M&L for Pre-cast cement concrete 1:1.5:3, type A-1, using 20mm graded stone aggregate as in window or door cills, lintels, bressumers, steps, quoin blocks (for use with masonry), string courses, copings. kneelers, apex stones, pier caps, columns, posts, boundary pillars, bed plates, pintle blocks, ancho-rage blocks, bonders (for stone walling). corbels, brackets, etc. (of any section indicated), with plain fair faces, including chamfers, weatherings, throating etc. and setting in mortar complete with joints to match set in CM 1:4 incl demolition of old reinforcement cement concrete (Reinforcement cut as required to facilitate demolition) complete all as specified and directed. |
| 26 | M&L Mild Steel TMT bar 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire not less than 0.90mm dia or securing with clips complete all as specified and directed. |
| 27 | S&F Mild steel framed works such as grills,gratings,etc, with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; framed balusters; walk ways; railings; framework of water tanks and similar work for portions framed and hung as gates, including pintle hinges, stops, hand made sliding bolts, etc conforming to Fe 290 Gde -E-165 complete all as specified and directed. (Note :-The rates include for riveting and/or welding as directed and fixing with screws, bolts, etc. complete) |
| 28 | M & L for preparation of new steel surfaces any description over 10 cm width or girth and applying two coat of synthetic enamel paint over a coat of red-oxide primer complete all as specified and directed. |
| 29 | Taking down copper /aluminium point wiring (light, fan, bell,socket or power) complete including fixture and fittings such as switches , ceiling roses , pendent , regulators, sockets, light fitting etc. Removing materials to store for keeping in safe custody or for taking credit (credit a for above items should be made as per condition seperately) and making good distrubed surfaces of walls, floors etc. |
| 30 | Taking down old/unserviceable distribution board by disconnection of electric connection carefully SPN DBs/TPN DBs/ Main Switch including old unserviceable MCCBs/ MCBs, Isolators, etc and making good to disturbed surface all as specified and directed at site. |
| 31 | Taking down carefully copper/aluminium Sub main wiring of any size from surface/concealed /existing conduit of any height and removing materials at site and making good disturbed surfaces of walls, floors roofs etc complete all as specified and directed. |
| 32 | M&L point wiring with 1.5 sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed FRLSH copper cable, 1100 volts grade, with multi stranded copper conductor drawn through and including non-metallic, rigid non mettalic PVC conduit (medium grade) concealed in wall / ceiling with and including 1.5 sqmm single core PVC insulated, multistranded, unsheathed, FRLSH copper conductor cable as continuous earth continuity conductor (green in colour) with cast Iron / pressed steel modular terminal boxes any size/module, conceiled on walls and fixed by neans of brass screws incl modular cover plates and cover frme any size/module, for mounting or housing switches, socket outlets, fan regulators, etc. including all other fixing accessories for the following complete for One light / fan /bell controlled by one, one way switch 5/6 Amps all as specified and as directed . |
| 33 | S&F in replacement of Ceiling rose three terminals surface bakelite type, AC, 50 HZ, 230V complete all as specified and directed. |
| 34 | S&F modular switch 1 way 6 A , 1 module complete all as specified and directed. |
| 35 | S&F ultra bright LED poly carbonate tube light fitting complete 4 feet long 18 to 20 watts with THD less than 15% very high effficiency suited for T-8 tube light luminare with system efficiency 120 lumens per watts. High quality polycarbonate end cap in white finish and snap fitted to the housing complete all as specified and directed. |
| 36 | S & F LED bldg security light fitting 30 watt made up of pressure die cast aluminium housing with acylic cover as diffuser with IP-66 protection complete incl mounting pipe made of GI tubing 40 mm size 1M length bend into size with mounting brackets nut bolt and washers all as specified and directed. |
| 37 | S&F MCB DB SPN 4 way ,IP-43, IK 09, double door type with metal door with 200 Amps rated bus bar ,230 volts, 50 Hz complete all as specifed and directed. |
| 38 | Supply & Fix MCB SPN 32 Amps current rating 'C' series 10 KA breaking capacitycomplete all as specified and directed. |
| 39 | Supply & Fix MCB SP 6 to 32 Amps current rating 'C' series 10 KA breaking capacitycomplete all as specified and directed. |
| 40 | M & L sub main wiring with 2 runs of 4 sqmm main wire along with 1 run of 4 sqmm earth wire (green in colour) single core FRLSH PVC insulated, unsheathed, multi-stranded, 1100 volts grade ISI marked copper conductor cable, drawn through and including adequate size rigid non-metallic PVC concealed / surface conduit (medium grade) wherever necessary with all fittings & accessories including cutting chases for conduits as required, sinking for terminal boxes, making good disturbed surfaces complete all as specified and directed.NOTE:- Two runs of main copper conductor, one run of earth wire and one run of PVC conduit shall be measured as one unit length. |
| 41 | Supply , laying and testing cable XLPE insulated screened pvc bedded galvanised steel strip or wire armoured electric power cables heavy duty 1100 volts grade with standard aluminium conductor of size 6.0 sqmm 2 core complete all as specified and directed. |
| 42 | Road cutting for laying of cable including making good as per existing all as specified and directed by Engr-in-Charge |
| 43 | Excavation in trenches, n. exc. 1.5 m wide and n.exc 1.5 m in depth ;for foundation, etc or for shaft, well, cesspit, manhole, pier holes etc.n. exc. 10 sq m on plan and n. exc. 1.5 m in depth and getting out soft/loose soil all as specified and as directed. |
| 44 | M&L fine sand cushioning for cable protection in layers incl punning all as specified and directed. Note : Punned thickness shall only be measured. |
| 45 | Supplying and laying un-reinforced precast concrete cable cover, Class LV, Type I, flat, size 250 mm x 150mm x 40mm all as specified and as directed. |
| 46 | S & F tubes, 'light grade,galvanised, with all fitting of size 40 mm laid in trenches for cable protection all as specified and directed. |
| 47 | Returning, filling in, trenches including spreading, levelling watering and well ramming in layers not exceeding 25 cm Soft / loose soil all as specified and as directed. |
| 48 | Removing excavated soil to a distance not exc 50 m and depositing where directed at a level not exc1.5m above the starting point all as specified and as directed. Please Enable Macros to View BoQ information |