| 1 | BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: COMMANDER WORKS ENGINEER, UDHAMPUR Name of Work: REPAIR /MAINT OF 11 KV ELECTRICAL SUPPLY DISTRIBUTION SYSTEM, CABLES, GODs, TRANSFORMERS AND OTHER ALLIED WORKS AT MPH AREA AND OTHER LOCATIONS UNDER GE (UTILITIES) UDHAMPUR Contract No: CWE/U(U)-21/2026-27 Bidder Name : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Ser.No. Item Description Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT Without Taxes TOTAL AMOUNT TOTAL AMOUNT In Words |
| 2 | Dismantling of existing GI earth/guard wire of any size and removing unserviceable GI wire form site complete all as specified and directed. |
| 3 | Dismantling of old unserviceable stay assembly including stay wire complete with necessary demolation of concrete excavation and earth work as reqd and removing the same from Site complete all as specified and as directed. |
| 4 | Dismantling of old U/S GOD 11 KV and DO fuse unit unit of any type and capacity complete all as specified and directed. |
| 5 | Dismantling of old UNSVdamage/rusted PCC pole/steel tubular poles of any Size necessary disconnecting cables/over head condcutor and removing unserviceable pole from Site complete all as specified and directed. |
| 6 | Taking down old unserviceable insulators any type and size from poles including for reuse or removal complete all as specefied and directed. |
| 7 | Dismantling of existing UNSV HT lightning arrestor form the electric pole and removing from Site complete all as directed. |
| 8 | Dismantling HT Danger notice plate from existing postion and removing from Site complete. |
| 9 | Pin Type, Porcelain vitreous, White, brown insulator of size 150 mm height, 150 mm dia for 11000 volts grade including one galvanised mild steel spindle , two galvanised iron washers and one galvanised iron nut in replacement, complete all as specified and directed. |
| 10 | Disc type insulator porcelain vitreous white brown or green as per IS 731-1963 of size 145 mm high and 255mm dia ball & socketed type single disc with tension clamp for working pressure 11000 volts complete all as specified and directed. |
| 11 | Supply and laying Galvanised steel wire 4.00 mm dia as continuous earth wire on over head conductor, Guard cradles on road crossing and stretching the same with required span, sag and binding the conductor with GI binding wire of approximate Size all complete all as specified and directed. |
| 12 | Supply and erection of steel tubular swaged pole 11.00 metres long designation 410-SP-55 complete with cast iron base plate, finial taper plug, bolts, nuts and screws etc. complete all as specified and directed. [Note :- Earth work and concrete foundation shall be measured and paid seperately under relevant items of Sch 'A'). |
| 13 | Excavation in trenches in soft/loose soil not exceeding 1.5 meter wide and not exceeding 1.5M in depth for laying of cables and getting out of excavated material complete all as specified and directed. |
| 14 | All as per item no. 13 here-in -before but exc 1.5 mtr depth and not exc 3 mtr deep complete all as specified and directed. |
| 15 | Returning, filling in, including spreading, leveling, watering and well ramming in layer not exceeding 25cm thick each complete all as specified and directed. |
| 16 | Removing excavated soil to a distance not exceeding 50 meter and depositing where directed at a level not exceeding 1.50 meter above the starting point complete all as specified and directed. |
| 17 | M&L PCC 1:4:8 type C-2 ( using 40mm graded stone aggregate) as in foundation of pole etc, complete all as specified and directed. |
| 18 | M&L PCC 1:2:4 type B-1 ( using 20mm graded stone aggregate) as in coping /stay including necessary from work complete for pole etc. complete all as specified and directed. |
| 19 | S&F double walled corrugated (DWC) pipe of size 120mm including snap fit coupler conforming to IS14930 (Pt-II)/IS16205 Pt-II for protection of LT cable in under ground complete all as specified and directed. |
| 20 | S&F double walled corrugated (DWC) pipe of size 160mm including snap fit coupler conforming to IS14930 (Pt-II)/IS16205 Pt-II for protection of LT cable in under ground complete all as specified and directed. |
| 21 | Taking up/down under ground cable 11000 Volt grade of Size 95 Sqmm to 185 Sqmm Sqmm, 03 core from trenches, ducts, floor, pipes and removing materials from Site of work complete all as directed by Engineer-in-Charge.(Note: Excavation and earth work shall be measured separately) |
| 22 | Supply, laying, commissioning and testing XLPE insulated screened PVC bedded galvanised steel strip or wire armoured electric power cable (Heavy Duty) with aluminium conductor 11000 volts grade cross sectional area 95 sq mm, 3 core complete all as specified and directed. |
| 23 | Supply, laying, commissioning and testing XLPE insulated screened PVC bedded galvanised steel strip or wire armoured electric power cable (Heavy Duty) with aluminium conductor 11000 volts grade cross sectional area 120 sq mm, 3 core complete all as specified and directed. |
| 24 | Supply, laying, commissioning and testing XLPE insulated screened PVC bedded galvanised steel strip or wire armoured electric power cable (Heavy Duty) with aluminium conductor 11000 volts grade cross sectional area 150 sq mm, 3 core complete all as specified and directed. |
| 25 | Supply, laying, commissioning and testing XLPE insulated screened PVC bedded galvanised steel strip or wire armoured electric power cable (Heavy Duty) with aluminium conductor 11000 volts grade cross sectional area 185 sq mm, 3 core complete all as specified and directed. |
| 26 | Material and labour forr checking the fault occure due to rain , heavy wind and any other breakdown related to 11 KV HT line and power house ,Rectify the fault at own arrangement complete with proper testing and commissioning of HT line .All spare and parts such as nut ,bolts,disc and pin insulator,streching of conductor and all other essential accessories required for fault rectification are included in the quoted rates. Note:- Contrator of his rep shall come to the site of breakdown within one hour of notification of breakdown. In case the rep or contractor shall not come to the site of breakdown and start attending breakdown within 1.00 hour a penalty of Rs 1000 per fault per hour will be imposed over contactor and will be deduct from his dues. |
| 27 | M&L for cutting/boring the existing bitumenous road/payment/footpath upto 0.75 mtr in depth, 0.45 mtr in width and getting out excavated material and making good the damaged portion after laying the pipe, returning filling in mass concrete PCC 1:2:4 type B2 upto top of the road all as directed by Engr-in-Charge. Note :-(i) M&L for laying of pipe shall be measured and paid separately. |
| 28 | Cable jointing kit for 11 KV (Earthed) grade cable for end termination heat shrink type joint outdoor type complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 to 185 sqmm, complete all as specified and directed. |
| 29 | Cable jointing kit for 11 KV (Earthed) grade cable for end termination heat shrink type joint outdoor type complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 to 95 sqmm, complete all as specified and directed. |
| 30 | Cable jointing kit for 11 KV (Earthed) grade cable for end termination heat shrink type joint intdoor type complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 to 185 sqmm, complete all as specified and directed. |
| 31 | Cable jointing kit for 11 KV (Earthed) grade cable for end termination heat shrink type joint intdoor type complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 to 95 sqmm, complete all as specified and directed. |
| 32 | Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm. complete all as specified and directed. |
| 33 | Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm. complete all as specified and directed. |
| 34 | Supply and fixing triple pole mechanically operated air break isolator (GOD), vertical mounting, rotating type, mounted on insulator and steel frame with operating mechanism worked from ground level complete in all respect such as gun metal moving contacts and spring loaded gun metal fixed jaws, knife copper jumper strip etc, suitable for 11000 Volts grade, 50 Hz, with 12 insulator of rating upto 400 Amps including taking down existing GOD complete and removing from SSRte complete all as specified and as directed. |
| 35 | Supply and fixing triple pole mechanically operated air break isolator (GOD), vertical mounting, rotating type, mounted on insulator and steel frame with operating mechanism worked from ground level complete in all respect such as gun metal moving contacts and spring loaded gun metal fixed jaws, knife copper jumper strip etc, suitable for 11000 Volts grade, 50 Hz, with 9 insulator of rating upto 200 Amps including taking down existing GOD complete and removing from SSRte complete all as specified and as directed. |
| 36 | S & F drop out fuse unit Single pole mounted on insulator, 11000 Volts grade double pole steel frame of current rating 50 Amps including taking down existing DO fuse unit complete and removing from Site complete all as specified and directed. |
| 37 | S & F Loop type insulator, vitreous porcelain, white or brown small SIze with overall dimension 65mm x 90 mm and clearance of hole 16mm complete all as specified. |
| 38 | S & F HT lightning arrestor for out door use expulsion type complete with all fittings,65 Kilo amps discharge capacity, distribution class. |
| 39 | S & F HT 11000 volts Danger notice plate of Size 25cm x 20cm made of 1.6mm thick mild steel plate, vitreous enamelled white, with letters, figures and conventional skull and bones in Signal red colour and fixed with MS clamps, bolts and nuts of approved Size complete all as specified and directed. |
| 40 | Earthing complete with GI steel earth plate electrode 60cm x 60cmx6.3mm thick barried directly in ground vertically to a depth not less than 2.25 metres below ground level with top edge of earth plate at a depth not less than 1.5 mtrs below level ground, connected to GI iron or steel earth wire 4mm dia (8 SWG) by means of nuts, volts checks nuts and washers made of GI iron or steel earth wire protected by GI iron pipe 15mm bore, medium grade and connected to main switch board or main control board as directed and including concrete pit in PCC (1:3:6) type C1, pre-cast RCC over slab 30cmx30cmx10cm with one lifting handle made of 8mm dia MS bar funnel wire mesh, 20mm bore GI or steel pipe medium grade for watering, charcoal or coke and salt in alternate larges, necessary excavation and earth work in any type of soil complete all as shown in electrical plate No 5 of MES schedule Part-I and testing after completion. |
| 41 | Earthing complete with copper earth plate electrode 60 cm x 60cmx 3.15 mm thick buried directly in ground vertically to a depth not less than 2.25 mtrs below ground level with top edge of earth plate at a depth not less than 1.5 mtr below ground level connected to copper strips 20x3 mm by means of nuts both check nuts and washers made of galvanised iron or steel earth strip protected by galvanised iron pipe 40 mm bore medium grade upto ground level as directed and including concrete pit in PCC ( 1 : 3 : 6) type C1 pre cast RCC cover slab 30 cm x 30 cm x 10 cm thick including reinforcement with 8 mm dia steel deformed bars at the rate of 10 cm both ways with one lifting handle made of 8 mm dia MS bar funnel, wire mesh 20 mm bore galvanised iron or steel pipe medium grade for watering charcoal on coke and salt in alternate layers, necessary excavation and earth work in any type of soil complete all as shown in electrical plate No 5 of MES schedule Pt-I and testing on completion |
| 42 | Earthing complete with galvanised steel earth plate electrode 60 cm x 60cmx 6 mm thick buried directly in ground vertically to a depth not less than 2.25 mtrs below ground level with top edge of earth plate at a depth not less than 1.5 mtr below ground level connected to galvanised iron strips 32 x 6 mm by means of nuts both check nuts and washers made of galvanised iron or steel earth strip protected by galvanised iron pipe 40 mm bore medium grade upto ground level as directed and including concrete pit in PCC ( 1 : 3 : 6) type C1 pre cast RCC cover slab 30 cm x 30 cm x 10 cm thick including reinforcement with 8 mm dia steel deformed bars at the rate of 10 cm both ways with one lifting handle made of 8 mm dia MS bar funnel, wire mesh 20 mm bore galvanised iron or steel pipe medium grade for watering charcoal on coke and salt in alternate layers, necessary excavation and earth work in any type of soil complete all as shown in electrical plate No 5 of MES schedule Pt-I and testing on completion |
| 43 | Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 25x4 mm dia galvanised iron or steel wire complete all as specified and directed. |
| 44 | Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4 mm dia galvanised iron or steel wire complete all as specified and directed. |
| 45 | S&F Stay assembly complete with acessories as shown in electrical plate no 1 (loop type insulator, stay clamps, stay wire, excavation and concrete measured separately) with 16 mm dia stay rod complete all as specefied and directed. |
| 46 | M & L for galvanised stay stand in repair of, Size 7/4 mm complete all as specified and directed. |
| 47 | Dismantling of cross arms fixed on steel tubular poles carefully and removing from Site complete all as specified and directed. |
| 48 | Cross arms of mild steel channel or angle sections of any Size and shape including clamps, back plate with bolts, nuts, washers drilled for insulator bolt, welding, bending cold or hot in any shape or Size as directed and painted with two coats of aluminium paint over a coat of red oxide primer complete all as specified and directed. |
| 49 | Dismantling of overhead ACSR (Aluminium conductor steel reinforced) from existing electric pole and removing unserviceable ACSR from Site complete all as directed. |
| 50 | M&L for Aluminium conductor steel reinforced (ACSR) on overhead electric lines and stretching the same with required span sag and binding the conductor with pin/shackle insulator and jumpers with aluminium binding wire not less than 2.00 mm dia complete all as specified and directed for any Size. |
| 51 | S & F GI tubing 80mm dia medium grade in protection of cable of different dia laid in trench under road/foot path or fixed on pole with necessary clamps with bolts etc complete all as specified and directed. |
| 52 | M&L in replacement, PVC insulated, high conductivity stranded alluminium conductor unarmoured of Size 120 Sqmm Single core dully coverd in HT 11 KV sleeves complete all as specified and directed. |
| 53 | M&L in replacement, PVC insulated, high conductivity stranded alluminium conductor unarmoured of Size 95 Sqmm Single core dully coverd in HT 11 KV sleeves complete all as specified and directed. |
| 54 | Preparing surfaces of steel tubular swaged pole 11 Mtr long with scraping out old paint by emmery paper, castic soda complete and painting with two coats of aluminium paint over a red oxide primer and writing the No of poles and feeder name complete all as specified and directed by Engr-in-Charge and stripping with black paint & yellow paint (300 mm each stripe) 5 Nos at equal distance from bottom (above PCC coping) upto a height of 1500 mm complete all as specified and directed. |
| 55 | Labour only for cutting/pruning the overhanging or adjacent branches of trees of any girth HT/LT overhead line including cutting the bamboos and cleaning the jungle below and upto 3.00 metre clear distance from the middle conductor of the line on either Side complete and removing rubbishes from Site all as directed. |
| 56 | Tightening and straightening of any type/Size/span overhead line of ACSR conductor/GI wire of any Size and span by disconnecting and removing from insulators and tightening the conductor by using rope, chain pulley block etc and binding the conductor on insulators with and including binding wire and jumpers of ACSR complete all as directed by the Engr-in-Charge.(Note : 03 run of ACSR conductor + 2 run of GI wire of any Size of length upto 40 to 50 RM will be measured as one span) |
| 57 | S & F HT UG cable PCC route marker of Size 900mmx80x50mm dully written HT UG Cable, GE (U) UDHAMPUR t with red strip marking of suitable Size inclued embeded in earth with necessary PCC works 40cmx40cmx40cm complete all as specified and directed. |
| 58 | Re-adjustment, cleaning of contact, greasing and testing of out door type air break switch 11 KV current rating upto 200 Amps including all materials required for alignment for AB/GO 11 KV switch in posting and replacement of unserviceable parts connections with and including lugs, GI nuts, bolts etc complete all as directed. (Note :- Replacement of unserviceable parts shall be measured and paid separately under relevant items). |
| 59 | Brass terminal plate for mounting male contact of AB/GO 11 KV 200 Amp switch insulator in replacement of old unserviceable plate including GI nuts and bolts washers etc as required complete all as specified and directed. |
| 60 | Male contact for AB/GO 11 KV 200 Amp switch in replacement of unserviceable old male contact, complete all as specified and directed. |
| 61 | All as per item No 59 but female contact, complete all as specified and directed. |
| 62 | M&L in replacement Post insulator for AB switch with metal part Suitable for HT 11 KV conforming to IS 5572-1972, complete all as specified and directed. |
| 63 | M&L in replacement Post insulator double stack for AB/GO 11 KV switch, complete all as specified and directed. |
| 64 | M&L in replacement DO insulator suitable for 11 KV with metal part conforming to IS 5572-1972, complete all as specified and directed. |
| 65 | Dismanting and taking down carefully existing UNSV air breather from out door/in door type step down power transformer of any capacity, complete all as specified and directed. |
| 66 | Supply and fix air breather complete with Silica gel suitable for out door type step down power transformer up to100/ 160 KVA, complete all as specified and directed. |
| 67 | Supply and fix air breather complete with Silica gel suitable for out door type step down power transformer up to 200 KVA to 500 KVA, complete all as specified and directed. |
| 68 | Disconnecting HT/LT Side electrical connection carefully existing 11 KV/415 Volt step down transformer of any capacity, draining out and refilling of existing transformer oil after filteration dehydration and measuring the dielectric strength which should not less than 50 KV including reinstallation of transformer satisfactory on its original position connecting testing and commissioning complete including all lighting arrangement with cable and other items for dehydration machine all as directed. |
| 69 | Supply only transformer oil of approved quality (Dielectric strength not less than 40 KV) ISI marked for filling in transformer for topping up complete all as specified and directed. |
| 70 | Disconnecting of all electric connection of defective distribution transformer 11/0.433 KV outdoor /indoor type , Opening top cover of transformer , taking out insulating oil upto lower level of bushing and keeping in clean & dry container (oil to be reused) for replacement of HT/LT Bushing , gaskets etc incuding refixing the same and refilling the drained out transformer oil complete, reconnection etc complete all as specified and directed :- Note :- Spare part and repair will be measured and paid for separately. |
| 71 | Supply and fix in repair HT bushing suitable for out door type 100/125/150/200/250/300/400 KVA transformers confirming to IS-334 complete with nut bolts brass studs and gasket of synthetic rubber bonded cork sheet all as specified and directed. |
| 72 | Replacement of ceramic bushing and Gasket on HT side of transformers of capacities 63 to 500 KVA capacities, complete all as specified and directed. |
| 73 | Replacement of ceramic bushing and Gasket on LT side of transformers of capacities 63 to 500 KVA capacities, complete all as specified and directed. |
| 74 | Supply and fix in repair LT bushing 1100 volt grade complete with nut bolts, brass studs, insulator and gasket etc suitable for out door transformer, complete all as specified and directed. |
| 75 | Replacement of ceramic bushing and Gasket on LT side of transformers of capacities 63 to 500 KVA capacities, complete all as specified and directed. |
| 76 | Supply and fix gaskets of any Size Transformer of any capacity after taking down unserviceable gaskets, complete all as specified and directed. |
| 77 | M&L for replacement of Off load tap changer of Transformer Rating from 100 KVA to 500 KVA as per the existing make of transformer, complete all as specified and directed. |
| 78 | M&L for painting of transformer after cleaning the body surface of transformer by rubbing with emery Ppper to remove oil stains, dust etc and applying two coat of snthetic enamel paint by spray paint incl writing SM No/MES No , capacity of transformers of following capacity all as directed by Engr-in-Charge. The contractor has to arrange their own local generator for supply to the spray painting machine, complete all as specified and directed. |
| 79 | 100 KVA to 200 KVA |
| 80 | 300 KVA to 400 KVA |
| 81 | Replacement of arc horn surge arrester complete with amounting ring, nut bolt etc of approved make suitable for transformers of capacity from 100KVA to 500 KVA.complete all as specified and directed. |
| 82 | M&L for rewinding of HT/LT coils of transformer of capacity 50 KVA to 100 KVA with super enamelled copper winding wire of existing gauge and proper number of turns alongwith insulating material i.e leatheroid, paper insulation, cotton tapes, empire tapes, wooden block packings, PVC sleeves, soldering and varnishing with insulating varnish , heating/drying etc complete all as specified and directed. |
| 83 | M&L for rewinding of HT/LT coils of transformer of capacity 100 KVA to 250 KVA with super enamelled copper winding wire of existing gauge and proper number of turns alongwith insulating material i.e leatheroid, paper insulation, cotton tapes, empire tapes, wooden block packings, PVC sleeves, soldering and varnishing with insulating varnish , heating/drying etc complete all as specified and directed. |
| 84 | M&L for rewinding of HT/LT coils of transformer of capacity 250 KVA to 630 KVA with super enamelled copper winding wire of existing gauge and proper number of turns alongwith insulating material i.e leatheroid, paper insulation, cotton tapes, empire tapes, wooden block packings, PVC sleeves, soldering and varnishing with insulating varnish , heating/drying etc complete all as specified and directed. |
| 85 | M&L for rewinding of HT/LT coils of E&M equipment of any capacity, type and size with super enamelled copper winding wire of existing gauge and proper number of turns alongwith insulating material i.e leatheroid, paper insulation, cotton tapes, empire tapes, wooden block packings, PVC sleeves, soldering and varnishing with insulating varnish , heating/drying etc complete all as specified and directed. |
| 86 | Taking down/dismantling and refixing of any capacity of transformer by using Hydra mechine complete and including tranportation shifting to approved manufacturer/Workshop including testing and commissioning all as directed. (Note- Dismantling and fixing after rewinding and Transportation from site to Workshop and workshop to site will be paid as one job) |
| 87 | Taking down/Dismantling of old unserviceable/corroded ACSR Conductor of any size from existing over head lines completed and supply, lay and fix aerial bunched cable 11KV grade stranded and compact aluminium phase conductor of size 3x120 sqmm + 1x70 sqmm (bare messenger) with Aluminium alloy as per IS-8130-1984 ans ISD 398(Part-4)-1979. The phase conductor shall be insulated with XLPE (Sioplas) compound Aluminium as per IS-14255-1995 & IS-7098(Part-2)-1985 including all fittings such as anchor clamp, suspension clamp, line connector, service clamp, Including End joints insulator piercing connectors, for taps from bare line etc. complete all as specified and as directed. |
| 88 | Taking down/Dismantling of old serviceable/corroded ACSR Conductor of any size from existing over head lines completed and supply, lay and fix aerial bunched cable 11KV grade stranded and compact aluminium phase conductor of size 3x95 sqmm + 1x70 sqmm (bare messenger) with Aluminium alloy as per IS-8130-1984 ans ISD 398(Part-4)-1979. The phase conductor shall be insulated with XLPE (Sioplas) compound Aluminium as per IS-14255-1995 & IS-7098(Part-2)-1985 including all fittings such as anchor clamp, suspension clamp, line connector, service clamp, Including End joints insulator piercing connectors, for taps from bare line etc. complete all as specified and as directed. |
| 89 | M&L in replacement, PVC insulated, high conductivity stranded alluminium conductor unarmoured of Size 50 Sqmm Single core dully coverd in HT 11 KV sleeves complete all as specified and directed by Total in Figures 0.0 0.0 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |