| 1 | Surface dressing n exc 15 cm deep In soft / loose soil all as specified and directed by Engineer-in-Charge. |
| 2 | Excavating over areas, not exc 1.5 m deep and getting out in soft /loose soil all as specified and directed by Engineer-in-Charge. |
| 3 | All as per item Sl item No. 2.00 here in above but depth exc 1.5m and not exc 3.0m all as specified and directed by Engineer-in-Charge. |
| 4 | M&L for Providing cement concrete type D-2, 1:4:8 ( using 40mm graded aggregate) as in foundation, filling and mass concrete and Base of plinth beam, sub base of floor etc. all as specified and directed by Engineer-in-Charge. |
| 5 | M & L for RCC M-25 Design mix concrete as in Column Footing , Column up to bottom of PB & in Plinth beam all as specified and directed by Engineer-in-Charge. |
| 6 | M & L for RCC M-25 Design mix concrete as in Col above Plinth Beam up to bottom of Roof Beam all as specified and directed by Engineer-in-Charge. |
| 7 | M & L for RCC M-25 Design mix concrete as in roof slab supported on Beam / Wall etc all as specified and directed by Engineer-in-Charge. |
| 8 | M&L for RCC M-25 in roof beam and lintel beam all as specified and directed by Engineer-in-Charge. |
| 9 | M&L for RCC M-25 in Chajja all as specified and directed by Engineer-in-Charge. |
| 10 | Formwork to sides of concrete foundations, footings, bases of columns, Column up to PB and plinth beam and similar work vertical or to batter fair finished surfaces all as specified and directed by Engineer-in-Charge. |
| 11 | Formwork to sides and soffits of roof/ floor beams, etc fair finished surface all as specified and directed by Engineer-in-Charge. |
| 12 | Formwork to sides and soffits of chajja etc fair finished surface all as specified and directed by Engineer-in-Charge. |
| 13 | Formwork to sides of pillers, posts,struts,piers,columns etc fair finished surfaces all as specified and directed by Engineer-in-Charge. |
| 14 | Formwork to sides and soffits of lintel beam etc fair finished surface all as specified and directed by Engineer-in-Charge. |
| 15 | Formwork to sides and soffits of Roof/ Slab etc fair finished surface all as specified and directed by Engineer-in-Charge. |
| 16 | M&L for steel reinforcement of TMT bars 10 mm dia and over cut to length and bent to shape required including cranking bending spirally, hooping for columns, hooking ends and binding with and including with mild steel wire (annealed ) not less than 0.9 mm dia or securing with clips all as specified and directed by Engineer-in-Charge. |
| 17 | All as per item Serial item No. 16.00 here in above but 8 to 10 mm dia dia in stirrups, spacers and binders all as specified and directed by Engineer-in-Charge. |
| 18 | Returning filling in including spreading leveling, watering and well ramming in layers not exc 25 cm thick using excavated soil all as specified and directed by Engineer-in-Charge. |
| 19 | Removing excavated soil to distance not exc 50 m and depositing where directed at a level not exc 1.5 m above the starting point all as specified and directed by Engineer-in-Charge. |
| 20 | M & L for Damp proof course to horizontal or vertical surfaces including necessary formwork all as specified and directed by Engineer-in-Charge. |
| 21 | M & L for hardcore of gauge not exceeding 63 mm of broken stone, deposited, spread and levelled layers not exceeding 15 cm thick, watered and rammed to a true surface all as specified and directed by Engineer-in-Charge. |
| 22 | M&L for PCC (1:2:4) type B1 using 20 mm graded stone agg as in sub base of floor 40 mm thick to receive tillimng etc all as specified and directed by Engineer-in-Charge. |
| 23 | M & L for Polythene film, black, 50 micron laid in floors all as specified and directed by Engineer-in-Charge. |
| 24 | M&L For Machine cut kota stone slab flooring 20-25mm thick over and incl 20mm thick cement screed bed in CM 1:6 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing all as specified and directed by Engineer-in-Charge. |
| 25 | M & L for Kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over cement screed bed 10mm in CM 1:4 and jointed all as specified and directed by Engineer-in-Charge. |
| 26 | M&L for 75 mm thick Cement concrete type C1, 1:3:6 (using 20 mm graded stone aggregate) in plinth protections, finished even and smooth w/o using extra cement all as directed. |
| 27 | M&L for rendering 15 mm thick on fair face of brick or concrete surface in cement mortar 1:6 as in internal plastering finished even & smooth without extra cement all as specified and directed by Engineer-in-Charge. |
| 28 | M&L for rendering 15 mm thick of brick or concrete surface in cement mortar 1:4 as in external plastering in two layers (10 +5) top coat of 5mm to be mixed with WPC @ 3% of cement finished otherfair & even all as specified and directed by Engineer-in-Charge. Note : WPC will be measured & Paid separately |
| 29 | Supply only Integral water proofing compound (WPC) all as specified and directed by Engineer-in-Charge. |
| 30 | M&L for rendering 10mm thick on sofit of RCC ceilling & Chajja surfaces in CM(1:3) finished even & smooth without extra cement all as specified and directed by Engineer-in-Charge. |
| 31 | M & L for Brickwork with subclass ‘B’ bricks using old size bricks straight or curved on plan not exc 6m mean radius built in CM 1:6 all as specified and directed by Engineer-in-Charge. |
| 32 | M&L for preparation of surfaces of new plaster surface of external wall and applying two coat of cement base paint over and including primer all as specified and directed by Engineer-in-Charge. |
| 33 | M&L for preparing New plastered surfaces of internal wall & applying two coats of distemper oil emulsion on surfaces of walls over one coat of alkali primer on plastered surfaces preparatory to distempering. |
| 34 | M&L for preparing New plastered surfaces of celling & applying two coats of distemper oil emulsion on surfaces of walls over one coat of alkali primer on plastered surfaces preparatory to distempering all as specified and directed by Engineer-in-Charge. |
| 35 | M & L for Rendering 10mm thick on top of RCC roof surface in Cm 1:4 & applying APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non woven fabric (wt. not less than 150 gms/sqm) laid on primed surface by forced/ torch application complete all as specified. |
| 36 | S & F Steel rolling shutters, with out ball bearing, as specified including top cover, an choring rod, hasp and staple and one shop coat of primer; erected in position as indi cated, complete: push pull or manual type with 1.25 mm thk of laths complete all as specified and directed by Engineer-in-Charge. |
| 37 | S & F Ball bearing for rolling shutters as per existing size & make all as specified and directed by Engineer-in-Charge. |
| 38 | S & F Safety lever locks mild steel with 4 levers for rolling shutters all as specified and directed by Engineer-in-Charge. |
| 39 | Providing and fixing factory made uPVG white colour Sliding window Three track made of extruded profiles with wall thickness of 2.3mm (+ -0.2mm). Window profile with hollow section with multi chamber. Frame (88mm x 52mm), sliding sash (42mm x 67mm). Sliding mesh Sash (42mm x 57mm) Sliding interlock (One vertical length in each shutters) (45.5mm x 28mm), Glazing bead (24.5mm x 16mm) will be miterd cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware. EPDM gasket, 1.2+ -0.2mm thick galvanised steel Frame (30mm x 18mm) 2 nos, sliding sash (30mm x 18mm), sliding mesh sash (26mm x 10mm) profile to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners, Hardware [Touch Lock of zinc alloyed (white powder coated), steel roller system. Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and required accessories. Note: The unit rate quoted by contractor excludes cost of glass and includes all other connected accessories all as specified and directed by Engineer-in-Charge. |
| 40 | Providing and fixing factory made uPVC white colour casement (Openable) window made of extruded profiles with wall thickness of 2.3mm ( + – 0.2mm). Window profile with hollow section with multi chamber, frame (60mm x 58mm), sash (60mm x 73mm), T profile (One vertical length in between two shutters) (60mm x 74mm), Glazing bead (35mm x 20mm) will be mitered cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware. EPDM gasket 1.2 +– 0.2mm thick, galvanized steel Frame (28mm x 21.5mm), sash (31mm x 27.5mm). T profile (27mm x 17mm) to be inserted in required profile, frame will be fixed to the wall with 8 mm x 100mm long fasteners. Hardware: [casement handle made of zinc alloyed (white powder coated), But Hinges of'zinc alloyed (white powder coated), transmission gear made of mild steel with multi point locking system] and 5mm thick glazing with selected quality glass. Note: The unit rate quoted by contractor excludes cost of glass and includes all other connected accessories all as specified and directed by Engineer-in-Charge. |
| 41 | S & F for Figured glass , pin head type and glazing with oil putty in squares not exc 0.5 sq. m in each pane |
| 42 | S & F Figured glass, pin head type and glazing with oil putty in squares exc 0.5 sq. m in each pane all as specified and directed by Engineer-in-Charge. |
| 43 | M & L for silicon sealent complete all specified and directed all as specified and directed by Engineer-in-Charge. |
| 44 | S & F for Aluminium anodised, barrel tower bolts of extruded section, length of bolt 200mm complete all as specified and as directed. |
| 45 | S & F Butt hinges, cast brass, with mild steel hinge pin, bright polished and fixed, typeB-11 all as specified and directed by Engineer-in-Charge. |
| 46 | S & F for Aluminium handles, cast type, anodised size of handle 150mm all as specified and directed by Engineer-in-Charge. |
| 47 | M & L for preparation and applying two coat of synthetic enamel paint on wooden surface over one coat of pink primer all as specified and directed by Engineer-in-Charge. |
| 48 | M & L for PCC 1:3:6 type C2 using 40mm graded stone aggregate as in surface channels and drains all as specified and directed by Engineer-in-Charge. |
| 49 | Dismantling plain or corrugated steel sheets in roof coverings etc complete all as specified and directed. |
| 50 | Dismantling Framed Truss not exc. 10 mtr span complete all as specified and as directed. |
| 51 | S & F vitreous china wash down water closet pan (pedestal pattern ) white with 'P' or 'S' trap plastic seat cover chromimum plated or aluminised hinging device including connection to outgoing pipe & flushing pipe anti syphonage pipe etc all as specified and directed by Engineer-in-Charge. |
| 52 | S & F 10 ltr capacity PVC valveless syphonic action type low level flusing cistern including 32 mm dia PVC flush pipe connection to WC with inlet , ball valve, flot and handle lever and fixing on walls woth bracket including 15mm PVC connection pipe all as specified and directed by Engineer-in-Charge. |
| 53 | S & F Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified. |
| 54 | S&F rolled mild steel Fe-410-W (Gde-E-250) quality-B as in Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc complete all as specified and as directed by Engineer-in-Charge. |
| 55 | S & F pre-painted color galvalume aluminium zinc coating GI based corrugated steel 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws as specified.Note : Galvalume sheet shall be 0.50mm thick (total coated thickness), 550 Mpa minimum, yield strength. It shall be coated with hot dip alloy of 55% Aluminium 43.5% Zinc 1.5% Silicon and finished with resin coat on both surfaces @ 150 gm/Sqm of coating (total both surfaces) having overall width and laid width as specified and shall be fixed using hot dip galvanized, self drilling and self tapping screws neoprene and EPDM washers all as specified and directed. |
| 56 | Demolition of Brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles etc all as specified and directed by Engineer-in-Charge. |
| 57 | S & F Factory Made Solid PVC Door Frame of size 50 x 47 mm made out of 5.0 mm thick plain colour PVC Sheet reinforced with Mild Steel Square Tube, fixing in opening as per Specifications and Drawings shown in MES Schedule Part-II, as in repair complete all as specified and as directed. |
| 58 | S & F Factory Made Solid Panel PVC Door Shutter 30mm thick, consisting of frame made out of Mild Steel Tube of 19 Gauge thickness and size of 19mm x 19mm for Stiles and 15mm x 15mm for Top & Bottom Rails. Mild Steel Frame shall have a coat of Steel Primer of Approved Make and Manufacturer. Mild Steel Frame shall be covered with 5.0mm thick heat moulded PVC 'C' Channel of size 30 x 50mm forming Stiles and 5.0mm thick, 75mm wide PVC Sheets For Top Rail, Lock Rail & Bottom Rail on either side, and 10mm (5.0mm x 2) thick, 20mm wide Cross PVC Sheet as gap insert for Top Rail, Lock Rail & Bottom Rail. Panelling of 5.0mm thick PVC Sheet Beading on either side and joined together with Solvent Cement Adhesive, etc. An additional 5.0mm thick PVC Strip of 20mm width is to be stuck on the interior side of the 'C' Channel using PVC Solvent Adhesive, fixing in opening as per Specifications and Drawings shown in MES Schedule Part-II, as in repair complete all as specified and as directed. |
| 59 | Supply and fix non skid ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exc 0.06 sqm but n exc 0.11 sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of the tiles over and incl 15 mm screed bed in CM(1:6) complete all as directed. |
| 60 | Material and labour for glazed ceramic tile of area not less than 300 mm x 450 mm in vertical surfaces of wall and thickness not less than 7 mm, jointed with neat cement slurry and pointed in white/coloured cement to match the surface laid over and including 10mm thick screed in CM(1:4) complete all as specified and as directed by the Engr-in-Charge. |
| 61 | Supply and laying 15mm bore tubes, galvinzed steel, medium grade, with all fitting and fixed complete on walls and celling or laid in floors complete all as specified and as directed by the Engr-in-Charge. |
| 62 | S & F in repairs 500 ltr Rotational moulded polye thylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I complete all as specified and as directed by the Engr-in-Charge . |
| 63 | S & F Bib tap standard of PTMT any colour high pressure screwed for iron pipe and fixed. (Minimum weight 15mm-90gms/20mm 125gms) omplete all as specified and as directed by the Engr-in-Charge . |
| 64 | S&F in repairs for 15 mm bore Stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed all as specified and as directed by the Engr-in-Charge . |
| 65 | S & F for viterous china wash hand basin white flat back size 550mm x 400mm including a pair of cast ironcantilever brackets of size 40 x40x5mm embedded inn PCC 1:3:6 type C -1 with & including 32mm dia PVC waste pipe and 32mm chromium plated brass waste fitting with long screwed sganks abd fly nuts flange end bedded in red lead cement & other end including pvc connection pipe 450mm long fixed as in repair complete all as specified. |
| 66 | S & F in repair Pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed all as specified and as directed by the Engr-in-Charge . |
| 67 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10.0 sq mm 2 core all as specified and directed. |
| 68 | Excavating in trenches manually not exceeding 1.5m wide and not exceeding1.5 mtr in depth/ width for laying under ground cable / foundations and getting out in soft / loose soil all as specified and directed. Note: During excavation no mechanical excavator is permitted at site, contractor will do the excavation through manually. |
| 69 | M&L for Double wall corrugated pipe of size 40/32 mm as per IS: 16205 Part-II-2013 laid in trenches/wall for protection cables complete all as specified and directed. |
| 70 | Material and labour for Point wiring with 1.5 Sqmm FR PVC insulated and sheathed multi stranded (FRLSH) copper conductor cable in and incl rigid PVC conduit concealed with sunk cast iron/pressed steel terminal boxes of adequate size with suitable thickness hylum laminated sheet , cover of adequate size for one light or one fan controlled by one switch incl 1.5 Sqmm (FRLSH) PVC insulated and unsheathed multi stranded copper conductor cable as earth wire(green colour) to common earth dolly complete all as specified and directed by Engr-in-charge. Note:- (a) Unit rate include for cutting chases for conduits and sinking for boxes and making good to wall, floors etc(b) On RCC roof ceiling PVC conduit shall be provided on surfaces for fan etc with proper fixing clips all as directed |
| 71 | All as per serial item No 70.00 here in before but for one 3 pin 5 Amp socket outlet on same board. |
| 72 | All as per serial item No 70.00 here in before but for one 3 pin 5 Amp socket outlet on independent board. |
| 73 | All as per item No.70.00 here-in-before but with two single core PVC insulated unsheathed multi stranded copper conductor cable (FRLSH) of size 4.0 Sq 1100 volts grade and one single core PVC insulated unsheathed multistranded copper conductor (FRLSH) of size 4.0 Sqmm 1100 Volts grade as earth continuity conductor (as per colour code) including PVC surface conduit (medium grade) of suitable size mm with all accessories such as bend, elbow, tee etc for 15 Amps switch socket combination point on independent board complete all as specified and directed. |
| 74 | S&F modular switch single pole one way, 16 Amp, AC,230 V all as specified and directed. |
| 75 | S&F modular socket 16 Amp, AC, 230V complete all as specified and directed. |
| 76 | S&F Metal flush box 4 module, complete all as specified and directed by Engr-in-charge |
| 77 | S&F Modular Plate 4 module White cover plate with frame, complete all as specified and directed by Engr-in-charge |
| 78 | S&F Metal flush Box 3 Module, complete all as specified and directed by Engr-in-charge |
| 79 | S&F Modular Plate 3 module White cover plate with frame, complete all as specified and directed by Engr-in-charge |
| 80 | S&F Metal flush Box 6 Module, complete all as specified and directed by Engr-in-charge |
| 81 | S&F Modular Plate 6 module White cover plate with frame, complete all as specified and directed by Engr-in-charge |
| 82 | M&L for Modular switch 6 A One way switch white, complete all as specified and directed by Engr-in-charge |
| 83 | M&L for Modular 6 A, 5 pin socket, complete all as specified and directed by Engr-in-charge |
| 84 | S&F rotary step modular electronic fan regulator (2 module) flush type AC, 230V, 120 W complete all as specified & directed. |
| 85 | S&F ceiling Rose, surface, bakelite 65 x50 mm three terminals (ISI Marked), AC, 230 Volts on PVC box complete incl taking down old unsv/ broken one all as specified & directed. |
| 86 | S&F sheet metal enclosure for DB’s SPN Double Door 8 way Glazed type, AC, 240 volt, IP 43 on the wall complete by masonry works/ cement plaster in cement mortar(1:6) & making good the disturbed surfaces and distempering /white washing to match the existing surface complete all as specified & directed. |
| 87 | S&F MCB SPN 20 to 32 Amps 240 Volts, 50 Hz, 10 KA breaking capacity complete all as specified & directed.Type ‘C’ Characteristic all as directed. |
| 88 | S&F MCB SP 6 to 20 Amps, 240 Volts 50 HZ, 10 KA breaking capacity complete all as specified & directed. Type ‘C’ Characteristic all as directed. |
| 89 | M & L for earthing complete with galvanised steel earth plate electrode 600 x 600x 6mm burried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edged of the plate not less than 1.5 mtr below normal ground level, connected to galavanised iron earth lead by means of bolt, nut, check nut and washer of galavanised iron steel wire 4mm as earthing lead as shown in Electrical Plate No 4 of SSR Part I connected to earthing test point all as specified or indicated including testing on completion including necessary excavation and earth work in soft/ loose soil, earth pit in PCC 1:3:6 type C1 using 20mm stone aggreate, funnel, 20mm dia GI med grade water pipe, 40mm dia GI light grade earth lead protection pipe, CI frame and cover, wire, copper lugs, wire mesh, charcoal or coke and common salt in alterative layer all around the earth electrode compacted thickness 15 cm including excavation and earth work pit cover including disposal of surplus soil to a distance not excessding 50m, complete testing on completion all complete as shown in electrical plate no-4 of SSR part No1 all as directed. |
| 90 | Supply, Installation, Testing and Commissioning of 1200 mm sweep BEE 5 star rated BLDC ceiling Fan, ISI marked , power less than or equal to 28watt , Class of insulation: B, Safety Rope, 100% copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 7.00, Air delivery minimum 215 Cum/Min, 350 RPM (tolerance as per IS: 374-2019), THD less than 10%, Blade Thickness : 1.08 mm , Electronic step regulator compatible for speed control, temperature rise 75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC, Leakage Current 210 Micro Amp Max, Two Ball Bearings , Powder coated, Surge Protection ( electronics ) upto 4 KV, Shall withstand 1.5 Kv, 50 Hz AC between current carrying and non-current carrying metal parts without any flash over for 1minute, Provision of Safety wire for additional safety of fan for falling down and all remaining accessories including safety pin, nut bolts, washers etc. |
| 91 | Supply and fix exhaust fan, steel body heavy duty AC single Phase. 230V of size 300mm sweep heavy duty with copper winding complete including making hole in existing wall and finishing with cement ratio 1:4 of 15mm thick plaster work on brick surface/concrete surface/stone with louvers/flip cover of exhaust fan made with 0.5 mm thick sheet in square/ round all as specified and directed by Engr-in-Charge |
| 92 | Supply and fixing of LED fitting 1x18 watts including Tube rod, 230 Volts, bipin holders connector block etc.complete with all accessories internally pre-wired and including provision of PVC round block 7.5cm dia and 2 cm in depth (2 Nos) for mounting the fittings and electrically connecting with three single core 23x0.0076 PVC insulated multistranded copper conductor flexible cable from ceiling rose to light fitting, complete all as specified and directed. |
| 93 | Supply, install, testing & commissioning of stand alone, all in one type Integrated LED Solar Street Lighting System of 24W capacity, 3000 Lumen beam angle 135/85, system efficacy > 100, CCT 5700, CRI> 70 with built in high efficiency solar panel of 90Wp mono crystal module & battery cap of 12V, 30 Ah, LiFePO₄ type with high efficiency micro processor based charge controller & PIR sensor, should have dusk to down operation & designed back up for 12 hrs at full or with dimming approx 24 hours and lighting system shall be equipped on 6.0 m long pole with base plate and finial taper plug, [nominal bore : 65mm, medium grade ] minimum 3.6 mm thick complete all as specified and directed. Make - Havells (Catno. SOLAR AIO 24 W),Philips / Orient Note : a) The 1/6 length of the pole shall be planted on the ground through earth and PCC works. The base for pole foundation shall be 0.6X0.6X0.01 m, foundation for the pole be 0.45X0.45X1.0 m and coping be .015m radius around the pole of 0.03 m long above ground level b) Earth work and PCC works shall be measured and paid separately, however form work for the PCC foundation shall be deemed to be included in this rate c) The manufacturer shall provide unconditional warranty for two years along with battery for solar lighting system excluding pole and contractor shall produce necessary documents for the same before taking any payment from the department. |
| 94 | M&L for PCC concrete 1:3;6 Type C-1 with 20mm graded aggregate for planting of poles /foundation incl. necessary formwork (as reqd) & rendering 10mm thick (CM 1:6) on fair faces of concrete surfaces above ground level all as specified and directed. Please Enable Macros to View BoQ information |