|
| 1 | Earth work in excavation in foundation trenches or drains (not exceeding 1.5 m in width as well as 10 Sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed. |
| 2 | P/L of dry stone soling duly hand packed including all carriages loading unloading complete job before laying of mud mate in trenches incl. all carriages of material involved & head load. |
| 3 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, with all leads and lifts complete |
| 4 | P/L in position cement concrete of specified grade excl. the cost of centering and shuttering: 1:4:8 (1 cement 4: coarse sand 8 graded stone crushed agg.40mm nominal size). |
| 5 | Reinforced cement concrete work upto plinth level excluding cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 Cement: 1.5 Coarse Sand: 3 graded stone aggregate 20mm nominal size- crushed.) |
| 6 | Providing/laying in position specified grade excluding the cost of centering & shuttering 1:2:4 (1 Cement: 2 Coarse Sand: 4 graded stone aggregate 20mm nominal size- crushed.) |
| 7 | Providing/laying in position specified grade excluding the cost of centering & shuttering 1:3:6 (1 Cement: 3 Coarse Sand: 6 graded stone aggregate 20mm nominal size- crushed.) |
| 8 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 150, landings, balconies, shelnes, chajjas, lintels, bands, plain window sills, stair cases and spiral stair cases upto floor V level excluding cost of centering, shuttering, finishing and reinforcement with (M-20 Mix) 1:1.5:3 (1 Cement: 1.5 Coarse Sand: 3 graded stone aggregate 20mm nominal size- crushed.) Incl all carraiges of material involved. |
| 9 | Reinforced cement concrete work in walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts upto floor five level including curing but excluding cost of centering shuttering, finishing and reinforcement. |
| 10 | Centring and shuttering including strutting proping and removal of form work for foundations, footings, bases of columns etc for mass concrete. |
| 11 | Reinforcement for R.C.C work including straightening cutting, bending placing in position and binding all complete. Thermo-Mechanically Treated bars of grade Fe-500D or more..Including carriage of all materials involved with loading unloading and stacking complete. |
| 12 | Brick work with FPS bricks of class designation 75 in foundation and plinth in cement mortar in 1:6 mix incl carraige of bricks upto site of work complete including extra upto floor V level. |
| 13 | Centring and shuttering including strutting proping and removal of form work for suspended floors, roofs, landings, balconies and acces. |
| 14 | Centering and shuttering including strutting, propping etc. and removal of form for: Lintel, beams, plinth beams, girders, bressumers and cantilevers |
| 15 | Centering and shuttering including strutting, propping etc. and removal of form work for: Columns, piers, abutments, pillars, posts and struts |
| 16 | Providing and fixing wood work in frames of doors windows clestory windows wrought frame and fixed in position of Imported Wood |
| 17 | Structural steel welded in built up sections, trusses and frame work, including soffits, eaves board etc including cutting, hoisting, fixing in position incl. applying a priming coat of approved steel primer all complete. |
| 18 | Providing and fixing precoated galvanized iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required |
| 19 | Providing and fixing precoated galvanised steel sheet roofing accessories0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : Ridges plain (500 - 600mm) |
| 20 | Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block 30x10x15 cm 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). |
| 21 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1cement :4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete Size of tile 500x500 mm |
| 22 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. |
| 23 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth and curing complete |
| 24 | 12mm thick cement plaster on the rough side of single or half brick walls of mix 1:6 ( 1 cement :6 coarse sand) (Interior as well as Exterior) |
| 25 | Providing and applying 2mm thick wall putty on walls to make surface even and smooth . |
| 26 | Providing and applying Plaster of Paris putty of 2mm thickness over plastered surface to prepare the surface even and smooth complete |
| 27 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade on New work (two or more coats) over and including priming coat with water thinnable cement primer |
| 28 | Applying priming coat with ready mixed Pink or grey primer of approved brand and manufacture on WOOD work (hard or soft wood) |
| 29 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade incl priming coat of wooden primer.( Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacturer ) |
| 30 | Providing and fixing panelled or panelled and glazed shutters for doors, windows and celerestory windows including ISI mark black enamelled butt hinges with necessary screws incl panelling of door shutters and glazing of windows Imported wood |
| 31 | Providing and fixing 35 mm thick factory made laminated veneer lumber door shutter conforming to IS : 14616 and TADS 15:2001 (Part B), fixing with butt hinges of required size with necessary screws, all complete as per directions of Engineer- in-charge and panelling with panels of : 12 mm thick pre-laminated particle board (decorative lamination on both sides) grade-I, medium density flat pressed three layer particle board FPT-I or graded wood particle board FPT-I, IS: 3087 marked, bonded with BWP type synthetic resin adhesive as per IS: 848 and pre-laminated conforming to IS:12823, Grade-I, Type-II marked : |
| 32 | Providing and fixing of glass panes 3.5 mm including cost of beading and nails all complete job |
| 33 | Providing and fixing wire gauze shutters using galvanized M.S. wire gauze of average width for aperture 1.4 mm in both directions with wire of dia. 0.63 mm for doors, windows and clerestory windows with ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws as per direction of Engineer-in-charge : 35mm Imported wood |
| 34 | Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 35 | Providing and fixing of hardware items of good quality including cost of screws all complete job |
| 36 | Handles 6\\" |
| 37 | Handles 4\\" |
| 38 | tbolt 4\\" |
| 39 | T bolt 6\\" |
| 40 | L drop |
| 41 | Supply and fixing the following sizes of rigid pvc conduits 1.8mm thick (ISI marked) complete with accessories such as bends, junction boxes , pull boxes etc in recess or on surface incl cutting chases in complete as required subject to actual details. 25mm dia rigid pvc conduits |
| 42 | 25mm dia flexible conduits |
| 43 | 20mm dia flexible conduits |
| 44 | Fan Boxes |
| 45 | Lightening concealed box |
| 46 | Carriage of materails By Mech.Transport, from source to site of work |
| 47 | Stone agg. for an avg lead of 15 km |
| 48 | Sand for an avg lead of 15 km |
| 49 | Bricks for an avg lead of 10 km |
| 50 | Carriage of materails By Manual Labour including loading, unloading and stacking for lead less than 0.50 km |
| 51 | Stone agg. including loading, unloading and stacking |
| 52 | Sand including loading, unloading and stacking |
| 53 | Bricks Please Enable Macros to View BoQ information |