| 1 | Maintenance |
| 2 | 1.10.2:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVCinsulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLSPVC insulated copper conductor single core cable etc as required.Group B |
| 3 | 1.55.1:Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group A |
| 4 | 1.15.1:Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required.Group A |
| 5 | 90.3.20.3:Supply & installation of light fittings on TW round block Supply, conveyance installation testing and commissioning the light fittings of following types made of CRCA with 0.5mm thickness complete with all accessories and lamps etc. directly on wall or ceiling with PVC round block neatly painted to suit the fitting and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS and giving connections as required.1200 mm 1X20W LED Lamp with box type fixture |
| 6 | 90.3.20.4:Supply & installation of light fittings on TW round block Supply, conveyance installation testing and commissioning the light fittings of following types made of CRCA with 0.5mm thickness complete with all accessories and lamps etc. directly on wall or ceiling with PVC round block neatly painted to suit the fitting and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS and giving connections as required.1200 mm 2X20W LED Lamp with box type fixture |
| 7 | 1.41:Installation, testing and commissioning of pre - wired, fluorescent fitting/ compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. |
| 8 | 90.3.18.2:Supply, fabrication, conveyance and fixing the following sizes of B class GI pipe bent to shape / cut and welded to shape and fixing the same to wall / parapet using clamps as noted along with each size, painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good the damages, colour washing etc as required.32 mm dia with HG company fabricated clamps |
| 9 | OD144531/2025-2026:Dismantling existing ordinary type tube /choke from fittings and Supply,Conveyance,installation, testing and commissioning of 1x18W LED pre-wired G13 base with extruded LED Tube poly carbonate body (cool white at 6500 K temprature ) 1200 mm, T8 I, 18 w with nominal system level lumen pakage of 2100 Lumen having effiency of minimum 115 lumen/watt, Inbuilt Driver with THD 0.95, RoHS compliant, suitable for use 140~280V AC 50 HZ AC supply. The light shall be made by Polycarbonate housing (IP20 protection) with minimum 3 KV surge protection. . The light should have minimum 70% of light at 40000 Hr life time as per LM 79 NABL Accradation certification. LED used in this light should be from manufacturer of Lumileds/Osram/Cree/Nichia make. .( Make -Philips/Equivalent) |
| 10 | 90.15.4.2:Supply Conveyance, installation, testing and commissioning of 36/40W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) |
| 11 | 90.15.4.3:Supply Conveyance, installation, testing and commissioning of 70W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD Less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) |
| 12 | 90.4.8:Charges for cutting holes suitable for accommodating exhaust fans up to 305mm sweep including plastering colour washing etc. as required. |
| 13 | OD116997/2025-2026:Supply, conveyance, installation, testing and commissioning of 300/305 mm, single phase, light duty exhaust fan in metal frame in the existing opening, fixing necessary bolt and nuts, making good the damages etc. as required including giving connections with required length of 24/0.20mm PVC insulated and PVC sheathed 3 core round copper conductor flex wire conforming to relevant ISS. |
| 14 | 1.33:Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. |
| 15 | 1.58:Supplying and fixing PVC batten/ angle holder including connection etc. as required. |
| 16 | OD144542/2025-2026: Supply and providing the 9 W LED bulb suitable for B 22 holder in the existing fittings as required.(Philips or its equivalent lumen type) |
| 17 | 90.4.1:Supply and installation of suitable size MS rod type fan clamp in the RCC slab as per IS 732 as required. |
| 18 | 90.4.2:Supply and installation of suitable size MS belt type fan clamp fabricated from flat iron 40 x 6 mm, 150mm long x 2 Nos with M.S. rod bent to shape, neatly painted with 2 coats of enamel paint over a coat of red oxide primer as per IS 732 as required. |
| 19 | 1.48:Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored) |
| 20 | 90.4.5.4:Supply, Installation, testing and commissioning of ceiling fan of following sizes including wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.1200mm sweep - ceiling fan complete with service value minimum 4.0(cub meter/minute/Watt), Air delivery minimum 210(cubic meter/minute), Copper winding suitable for 230V/240V single phase AC supply |
| 21 | 1.59:Dismantling of ceiling fan and painting the same with with one or more coats of spray painting with synthetic enamel paint of approved brand and manufacture to give an even shade, including cleaning of surface with detergent and replacing the damaged rubber reel, nuts and bolts with washers and safety pins reinstalling the same as required. |
| 22 | OD144546/2025-2026:Urgent maintenance of Electrical installation including attending petty repairs , cleaning, of light fittings ,ceiling fan and exhaust fan(excluding painting) ,checking all electrical connection in the DB and switch board. |
| 23 | OD144548/2025-2026:Charges for attending peety repairs ,Painting of Exhaust /ceiling fan in installed position with one or more coats of painting with synthetic enamel paint of approved brand and colour including checking bearing greasing and inter connections etc and tightening the connections etc as required |
| 24 | OD144549/2025-2026:Supply and replacement of Capacitor for Ceiling Fan |
| 25 | 1.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm |
| 26 | 1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm |
| 27 | 1.24.1:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch |
| 28 | 1.24.3:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch |
| 29 | 1.24.4:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet |
| 30 | 1.24.5:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet |
| 31 | 1.25:Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 32 | 1.27.2:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm) |
| 33 | 1.27.4:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200mmX75mm) |
| 34 | OD116996/2025-2026:Urgent maintenance of Electrical installation including attending petty repairs , cleaning, of light fittings ,ceiling fan and exhaust fan ,checking all electrical connection in the DB and switch board. |
| 35 | OD116771/2025-2026:Supply conveyance, installation, testing and commissioning of 3600 lumen round/ square(1X1)surface mount fitting made of diecast aluminium, having efficacy not less than 110l/w, 4000 to6000K, pf greater than 0.95, THD less than or equal to 10%, (Chip makeCree/Osram/lumilled/Nichea) and giving connections with 16/0.20 mm 3 core PVC insulatedand sheathed round copper conductor flex wire or extending the original wiring and givingconnections as required. Make: Philips/Osram/Havells or its equivalent. |
| 36 | OD116772/2025-2026:Supply conveyance, installation, testing and commissioning of 1800 lumen round/ square(1X1)surface mount fitting made of diecast aluminium, having efficacy not less than 110l/w, 4000 to6000K, pf greater than 0.95, THD less than or equal to 10%, (Chip makeCree/Osram/lumilled/Nichea) and giving connections with 16/0.20 mm 3 core PVC insulatedand sheathed round copper conductor flex wire or extending the original wiring and givingconnections as required. Make: Philips/Osram/Havells or its equivalent. |
| 37 | OD116774/2025-2026:Charges for dismantling tube light/ceiling fan/wall fan and conveyance to sectionstore etc as required. |
| 38 | OD116775/2025-2026:Charges Painting of stiff (fan/tube) in installed position with one or more coats of Brush painting with synthetic enamel paint of approved brand and Colour as required. |
| 39 | OD116776/2025-2026:Supply and renewal of cotter pin for ceiling fan condenser in the place of damaged ones as required. |
| 40 | OD116777/2025-2026:Supply and renewal of 2.5 mfd ceiling fa condenser in the place of damaged ones and giving connections as required. |
| 41 | 2.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Single pole |
| 42 | 2.11:Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 43 | 2.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps |
| 44 | 2.13.1:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps |
| 45 | 2.14.2:Supplying and fixing following rating, double pole, (single phase and neutral),240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps |
| 46 | 2.15.1:Supplying and fixing following rating, four pole, (three phase and neutral), 415volts, residual current circuit breaker (RCCB), having a sensitivity current 30milli Amperes in the existing MCB DB complete with connections, testing andcommissioning etc. as required.25 amps |
| 47 | 2.15.2:Supplying and fixing following rating, four pole, (three phase and neutral), 415volts, residual current circuit breaker (RCCB), having a sensitivity current 30milli Amperes in the existing MCB DB complete with connections, testing andcommissioning etc. as required.40 amps |
| 48 | 2.15.3:Supplying and fixing following rating, four pole, (three phase and neutral), 415volts, residual current circuit breaker (RCCB), having a sensitivity current 30milli Amperes in the existing MCB DB complete with connections, testing andcommissioning etc. as required.63 amps |
| 49 | OD141557/2025-2026:Supply and fixing following HRC fuse link up to - 160 A etc as required. |
| 50 | OD141566/2025-2026:Checking Panel board and rectifying the defects if any and Cleaning and painting of Panel in installed position with one or more coats of spraypainting with synthetic enamel paint of approved brand and manufacture. |
| 51 | OD145770/2025-2026:Supply and fixing 8 stage 440 / 110 V 5A/1A , Intelligent Power Factor Controllers (IPFC) |
| 52 | OD145771/2025-2026: Charges for checking electrical connections, operations in the existing panel board MSB and APFC , checking earth connection, wiring, petty repairs and cleaning the panel board room etc as required. |
| 53 | OD184851/2025-2026:SITC of 5 KVAR capacitor for APFC panel etc as required. |
| 54 | OD184852/2025-2026:SITC of 10 KVAR capacitor for APFC panel etc as required. |
| 55 | OD184853/2025-2026:SITC of 20 KVAR capacitor for APFC panel etc as required. |
| 56 | OD186926/2025-2026:One time Servicing and petty repair of 1TR/ 2TR/3TR 240/415V , Wall Mounting type Split Air Conditioner Units covering all maintenance and rectifying the defects if any (excluding the cost of spare). The cleaning and servicing of IDU and ODU includes water servicing using chemicals, water pump, Checking electrical connection , tight mechanical parts and finally patch work etc. The operating status of the units should be monitored and intimated to the department staff in charge and the Air conditioner Units should be maintained in proper working condition |
| 57 | OD184873/2025-2026:Supply and filling Refrigerant Gas for AC compresser |
| 58 | OD185216/2025-2026:Cleaning and painting of AC Bracket in installed position with one or more coatswith synthetic enamel paint of approved brand and manufacture. |
| 59 | OD185242/2025-2026:Supply and fixing one number 32 A ( AC1 rating ),4 pole, power Contractor with AC coil with AC coil with 2 Nos ,2 NC auxiliary contacts in the existing panel assemble as required. |
| 60 | OD185241/2025-2026:Supply and fixing one number 40A ( AC1 rating ),4 pole, power Contractor with AC coil with AC coil with 2 Nos ,2 NC auxiliary contacts in the existing panel assemble as required. |
| 61 | OD145767/2025-2026:Refilling of FIRE EXTINGUISHER 6 kg :- Renewing powder and Cartridge of 6kg Fire extinguisher if it failed in pressure test, including replacing cartridge, dry chemical powder and painting the shell with postoffice red synthetic enamel paint, , new labeling and fitted in the same location as required. |
| 62 | OD141567/2025-2026:Painting letters or figures of the following sizes with enamel paint as identification mark to SB, DB, panel board etc as required - 2.50 cm, 4 cm or 5 cm height |
| 63 | OD185269/2025-2026: Painting of Transformer Yard outer grill in installed position with 2 coats synthetic enamel paint over a coat of red oxide primer approved brand including cleaning the grill etc as required. |
| 64 | OD187311/2025-2026: Annual One Time Maintenance Service Contract For Diesel Powered Electric Generators ( 32/40/63 KVA )at the site by an authorized company technician, including <br>1.Checking, Overall condition/appearance of equipment (controls, leaks, loose wires).<br>2. change all fuel and oil filters in this contract and if required change the belts and the amount will be paid separately.<br>3. Inspect and adjust rack on unit injector or fuel distributor pump according to manufacturer's instructions. Check injector pump and injectors and verify flow rate, pressure, and spray pattern. <br>4. Adjust the governor for proper operating speed if required.<br>5. Flush cooling system and check hoses. Replace hoses if required by COR. Replace coolant by the contractor and hose if required and the payment for that items will be made separately. I<br>6. Brush and clean the coolant heat exchanger, in and out and painted the outer metal cover.<br> 7. Tighten control and power wiring connections.<br> 8. Check the calibration of voltage-sensing relays/devices.<br> 9. Change Lubricating oil. Review the Material Safety Data Sheet (MSDS) for proper disposal of used oil. (the charge for the oil given separately)<br>101. Inspect and clean generator rotor, stator, exciter and battery Charger etc.<br>11. Check the vibration of the Engine.<br>12. Clean voltage regulator, and control panel etc <br>13. Measure and record resistance reading of generator windings with insulation tester (Megger).. <br><br>14. Inspect safety shutdown devices. This includes simulated faults on low oil pressure cut-off, high water temperature cut-off, over-speed cut-off and failed start.<br><br>15. Check generator bearings and bearing grease. Lubricate in accordance with manufacturer's instructions. <br>16. Visually check bus bars, bracing, and feeder connections for cleanliness and signs of overheating. <br>17. Perform other work prescribed by the manufacturer and reported Overall Condition Assessment of the DG set.<br>18Run generator set (under load) to check voltage, check frequency, check instrument system and make adjustments.<br>19. Clean generator room/cabin and remove all debris.<br><br>as per the manufactures checklist and make the unit a good working condition.and servicing of the Diesel Generator set which includes replacing minor spares which are supplied by the consumer, attending break down calls, filling sufficient quantity water in radiator, arrest the leakage of oil or water if any, checking and cleaning battery terminals, applying petroleum jelly, check the density of electrolyte in battery, filling sufficient quantity distilled water in battery, check the connection of in built panel and make DG set in perfect working condition at all times during its operation.(Parts supplied separately) |
| 65 | OD187312/2025-2026:Supply of good grade Engine oil (15W 40 ) suitable for Diesel Engines, including conveyance, loading, and unloading, etc at the site as required. |
| 66 | OD187313/2025-2026:Supply of good quality company makes Diesel oil Filter suitable for Diesel Engine having capacity between 32 BHP to 80 BHP including conveyance etc as required. |
| 67 | OD187314/2025-2026:Supply of good grade Company manufactured type Heat exchangeable type coolant suitable for Diesel Engines, including conveyance, loading, and unloading, etc at the site as required. |
| 68 | OD187315/2025-2026:Charges for Painting of Generator Exhaust pipe 50/75 mm and supports in installed position with one or more coats of paint, heat resistant aluminum paint based on silicone resin medium for protection of steel surface upto 600° C. including scraping, cleaning the pipe with sandpaper/wire brush and tightening all the nut and bolt-on the flange, supports, etc before paining as required .safety of the labors should ensure the contractor. |
| 69 | OD187318/2025-2026:Supply of Distilled/Deionized Lead acid battery water (5 Liter Bottle) |
| 70 | OD187328/2025-2026:Charges for maintenance of existing Plate Earthing including accessories, and removing masonry enclosure and cleaning the earth chamber and replacing damaged nut and bolt if required and checking all connection , re legging and checking earth reading with megger etc. |
| 71 | OD187329/2025-2026:Supply of 11 KV graded Electrical Hand Gloves |
| 72 | OD187330/2025-2026:Supply, conveyance and paving good qulity Stone aggregate (single size) 40 mm nominal size in substation yard to imporve the system insulation level after removing all waster and grass at there as required . |
| 73 | OD187340/2025-2026:Dismantling existing damaged Air Breaker switch from the existing 4 pole metal structure and Supply, installation, testing and commissioning of new ISI make outdoor type 200A air break switch suitable for 11 KV operation including all accessories nut and bolt etc. and giving connection as required. |
| 74 | OD187354/2025-2026:Painting with aluminium paint of approved brand and manufacture to give an even shade.two or more coats on existing I-beam , angle iron structure etc. After applying one coat metallic primer .The substrate to be treated must be cleaned to remove oil, grease and loose paint residue. All residues must be removed. If applying thicker layers, allow to dry between coats. Please Enable Macros to View BoQ information |