| Sl. No. | Item Description |
| 1 | HSR PART[11.100.2]Applying a coat of mordant solution on G.S. sheet: 2. With a solution made of 13 gms of hydrochloric acid in a solution of 13 gms each of copper chloride, copper nitrate and ammonium chloride dissolved in a litre of soft water [Through Rate] |
| 2 | [11.73.1]Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer`s specifications including appropriate priming coat, preparation of surface, etc. complete. 1. On steel work [Through Rate] |
| 3 | [11.99.1]Painting on G.S. sheet with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : 1. New work (two or more coats) including a coat of approved steel primer but excluding a coat of mordant solution [Through Rate] |
| 4 | [20.71.1]Supply, erection, testing of Ceiling fans IS marked (as per IS code 374) with suitable GI pipe complete in all respects complete as per directions of Engineer-in-charge 1. 48\\" (1200mm) [Through Rate] |
| 5 | [20.72]Supplying, errection, testing of Exhaust fan (as per IS code 374) having a capacity of 45 cubic metre per minute complete with suitable G.I sheet ducting in structure confirming to latest IS specifications complete in all respect to satisfaction of Engineer-in-charge. [Through Rate] |
| 6 | [20.86]Supply, erection, testing and commissioning of G.O. Switch two poles, with blade, pin 6 insulators operating handle with GI pipe 25 mm class B complete in all respects. [Through Rate] |
| 7 | [22.173.1]Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design : 1. With common burnt clay non-modular bricks of class designation 7.5 [Through Rate] |
| 8 | [22.174.1]Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : 1. With common burnt clay non-modular bricks of class designation 7.5 [Through Rate] |
| 9 | [23.10]Erection of cabin fan complete with necessary earthling including carriage from PWD store to the site of work. [Through Rate] |
| 10 | [23.14]Replacement of rubber reel and Locking Split/safety Pin . [Through Rate] |
| 11 | [23.15]Replacement of ball bearing of a ceiling fan including greasing, re-assembling and testing etc. [Through Rate] |
| 12 | [23.16]Replacement of a bush bearing of any fan including turning, oiling, re-assembling and testing etc. [Through Rate] |
| 13 | [23.17.1]Replacement of a fan condenser complete with connections and testing etc. 1. 2 to 3.5 mfd. [Through Rate] |
| 14 | [23.19.2]Painting of pole with brackets etc with 2 coats of enamelled paint or other approved paint. 2. Above 5 metres but up to the height of 8 metres [Through Rate] |
| 15 | [23.19.3]Painting of pole with brackets etc with 2 coats of enamelled paint or other approved paint. 3. Above 8 metres [Through Rate] |
| 16 | [23.20]Fixing of LED Tube light/ 2*2 ft square panel fitting directly on wall /ceiling or false ceiling including making connections etc as required [Through Rate] |
| 17 | [23.21]Fixing of LED Down lighter 7 to 28 Watt on ceiling or in false ceiling , including cutting/making hole in ceiling including making connections etc as required [Through Rate] |
| 18 | [23.22.1.10]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.10. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. 4 pole MCCB 125 to 160 amp, 25 KA [Through Rate] |
| 19 | [23.22.1.11]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.11. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. 4 pole MCCB 200 to 250 amp, 25 KA [Through Rate] |
| 20 | [23.22.1.12]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.12. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. 4 pole MCCB 300 to 400 amp , 50 KA [Through Rate] |
| 21 | [23.22.1.13]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.13. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. 4 pole MCCB 600 to 800 Amp , 50 KA [Through Rate] |
| 22 | [23.22.1.3]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.3. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. TRIPLE POLE MCCB 16 to 100 Amp, 25 KA [Through Rate] |
| 23 | [23.22.1.4]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.4. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. TRIPLE POLE MCCB 125 to 160 Amp, 25 KA [Through Rate] |
| 24 | [23.22.2.2]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 2.2. MCCB Enclosure made of Sheet Steel suitable for mounting MCCB of following ratings MCCB up to 250 A FP [Through Rate] |
| 25 | [23.22.5.1]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.1. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 6 amp. to 32 amp Single Pole [Through Rate] |
| 26 | [23.22.5.3]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.3. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 6 amp. to 32 amp Double POLE [Through Rate] |
| 27 | [23.22.5.4]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.4. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 40 amp to 63 amp. Double pole [Through Rate] |
| 28 | [23.22.5.6]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.6. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 40 amp to 63 amp. MCBs TRIPLE POLE [Through Rate] |
| 29 | [23.22.5.8]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.8. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 40 amp to 63 amp. MCBs FOUR POLE [Through Rate] |
| 30 | [23.23.5.1]MISCELLANEOUS 5.1. Supply and erection of U- PVC Trunking/Channel of following size including cost of fixing on wall, floor and ceiling etc. with required material complete the job in all respect up to entire satisfaction of the Engineer-in-charge of work. 25x12 mm [Through Rate] |
| 31 | [23.23.6.3]MISCELLANEOUS 6.3. Supply and erection of MS cable tray , duly pained as required including erection of the same on wall or ceiling with necessary fixture and other material required to complete the job in all respect up to the entire satisfaction of Engineer-in Charge of the work. MS perforated cable tray painted with powder coating 375 X 50 X 2 mm [Through Rate] |
| 32 | [23.23.7.3]MISCELLANEOUS 7.3. Supply and erection of cable tray cover made of 1.25 mm thick GI sheet as required including erection of the same on existing cable tray with necessary fixture and other material required to complete the job in all respect up to the entire satisfaction of Engineer-in Charge of the work. GI cable tray Cover , suitable for cable tray of 375 X 50 X 2 mm metre [Through Rate] |
| 33 | [23.23.9]MISCELLANEOUS 9. Supplying and drawing of 1 no UTP 4 pair CAT 6 LAN Cable in the existing surface/recess MS/PVC conduit as required [Through Rate] |
| 34 | [23.24.1]MS STAND, BUS BAR CHAMBER AND PANELS 1. Supply and erection of M.S. angle iron frame duly welded for housing M.S. sheet & main switches etc. on it, fixed on wall by means of suitable size of rag bolts with cement concrete, duly painted with three coats of approved paint including one coat of red oxide. [Through Rate] |
| 35 | [23.26.2]SAFETY ITEMS 2. Supply and erection of High Tension Voltage caution notice plate of size 250*200 mm in three languages. [Through Rate] |
| 36 | [23.27.6]Supply and erection of Godrej Almirah typeM.S. pedestal made of 50 mm x 50 mm x 6 mm angle iron frame with 3.00 mm thick M.S. sheet covering including shutters with suitable hinges and locking arrangement with Godrej type handle including round bars . The top covering should have downward overhang of 75 mm on all sides of pedestal , having two sets of water proof ventilation holes of suitable size on the sides , at top and bottom , each set containing four Nos. holes to discharge the heat produced by the current . The shutters fixed with rubber gasket of superior quality and of suitable size to make it water proof . The pedestal duly painted both inside and outside with two coats of approved paint and primary coat and its legs are embeded upto the entire depth in 1:2:4 cement concrete block , projected 75 mm all around the pedestal and and 200 mm above the ground level including the cost of all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-in-charge of the work:- 6. M.S. pedestal of size 1500 mm wide , 1800 mm high ,450 mm deep and bottom totally open , duly embeded in cement concrete block of size 1650 mm x 600 mm x 200 mm above ground level , having a base of size 1800 mm x 750 mm x 250 mm below ground level . 0 0 [Through Rate] |
| 37 | [23.5.6.1]COPPER WIRING IN EXISTING PVC/MS CONDUIT PIPE SURFACE/RECESSED FOR ELECTRICAL POINTS 6.1. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in existing MS/PVC Conduit etc as required. 1 run of Size 1.50 Sqmm(1/1.40mm) [Through Rate] |
| 38 | [23.5.6.5]COPPER WIRING IN EXISTING PVC/MS CONDUIT PIPE SURFACE/RECESSED FOR ELECTRICAL POINTS 6.5. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in existing MS/PVC Conduit etc as required. 1 run of Size 10 Sqmm(1/3.50 mm) [Through Rate] |
| 39 | [23.8.11.1]FITTING AND ACCESSORIES 11.1. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. 5 amp 1 way switch [Through Rate] |
| 40 | [23.8.11.11]FITTING AND ACCESSORIES 11.11. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. RJ 45 Computer DATA socket outlet for CAT 6 or CAT6e cable Modular type [Through Rate] |
| 41 | [23.8.11.3]FITTING AND ACCESSORIES 11.3. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. 15 amp 1 way switch [Through Rate] |
| 42 | [23.8.11.4]FITTING AND ACCESSORIES 11.4. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. 5 amp Socket [Through Rate] |
| 43 | [23.8.11.5]FITTING AND ACCESSORIES 11.5. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. 15 amp 6 pin Socket [Through Rate] |
| 44 | [23.8.11.7]FITTING AND ACCESSORIES 11.7. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. step type Fan Regulator 2 modules 300 watt [Through Rate] |
| 45 | [23.8.9]FITTING AND ACCESSORIES 9. Supply and erection direct reading LCD Display Digital Ammetre/Voltmetre ( without CT or PT ) on wall/existing penal complete in all respect with necessary connections [Through Rate] |
| 46 | [24.1.1]EARTHING AND LIGHTENING ARRESTOR 1. Earthing with GL earth pipe 4.5 m long and 40 mm dia with masonry enclosures on the top etc. (but without charcoal or coke and salt) as required. [Through Rate] |
| 47 | [24.1.10]EARTHING AND LIGHTENING ARRESTOR 10. Providing and fixing 25 mm x 5mm copper strip on surface or in recess for connections etc. as required with all labour and material. [Through Rate] |
| 48 | [24.1.14]EARTHING AND LIGHTENING ARRESTOR 14. Supply and erection of 20mm x 3 mm thick GI, tape fixed with suitable G.I. staples of same size. [Through Rate] |
| 49 | [24.1.16]EARTHING AND LIGHTENING ARRESTOR 16. Supply and erection of 25mm dia 1.5 metre long lightning GI. tube rod tapered into a point at the top with 16cm x 16cm x 3mm thick G.I. base plate and necessary nuts and bolts with washers. [Through Rate] |
| 50 | [24.1.17]EARTHING AND LIGHTENING ARRESTOR 17. Providing and fixing testing joints made of 20mm x 3mm thick G.I. strips 125 mm long with 4 nos. G.I. bolts and nuts with washers complete. [Through Rate] |
| 51 | [24.1.2]EARTHING AND LIGHTENING ARRESTOR 2. Extra for using salt and char coal/coke for pipe earth electrode as required. [Through Rate] |
| 52 | [24.1.3]EARTHING AND LIGHTENING ARRESTOR 3. Earthing with G.I. earth plate 600 mmx 600 mm x 6 mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt) complete as required. [Through Rate] |
| 53 | [24.1.4]EARTHING AND LIGHTENING ARRESTOR 4. Earthing with tinned copper earth plate 600mmx600mmx3mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt) etc. complete as required. [Through Rate] |
| 54 | [24.1.5]EARTHING AND LIGHTENING ARRESTOR 5. Extra for charcoal or coke and salt for G.I. plate or copper plate earth electrode. [Through Rate] |
| 55 | [24.1.7]EARTHING AND LIGHTENING ARRESTOR 7. Supplying and laying 25mm x 3 mm G.I. strip in 40 mm dia,GI pipe as/from earth electrode including soldering etc. as required. [Through Rate] |
| 56 | [24.1.8]EARTHING AND LIGHTENING ARRESTOR 8. Providing and fixing 25 mm x 3mm G.I. strip on surface or in recess for connections etc. as required with all labour and material. [Through Rate] |
| 57 | [24.10.1]CIVIL ITEMS (USED COMMONLY IN ELECTRICAL WORKS) 1. Digging & refilling of trench 30 cm wide below ground level for erection of pipe/cable (up depth of 1 Metre. underground cable excluding the cost of cable/pipe complete in all respect. [Through Rate] |
| 58 | [24.10.4]CIVIL ITEMS (USED COMMONLY IN ELECTRICAL WORKS) 4. cement concrete 1:2:4 with stone aggregate 20 mm nominal size in Kerbs and the like items, finished smooth with 6 mm thick cement plaster 1:3 on exposed surface including from work, placing and fixing in position, complete at the ground level or in first storey [Through Rate] |
| 59 | [24.10.6]CIVIL ITEMS (USED COMMONLY IN ELECTRICAL WORKS) 6. Digging of pucca road in required width for laying of cable / pipe complete in all respect up to the entire satisfaction of Engineer-in charge [Through Rate] |
| 60 | [24.14.100]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE ONSURFACE/ EXISTING CABLE TRAY COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 100. 400 Sq mm 3.5 core (Arm.) [Through Rate] |
| 61 | [24.14.13]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE ONSURFACE/ EXISTING CABLE TRAY COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 13. 10 Sq mm 2 core (UnArm.) [Through Rate] |
| 62 | [24.14.24]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE ONSURFACE/ EXISTING CABLE TRAY COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 24. 16 Sq mm 4 core (Arm.) [Through Rate] |
| 63 | [24.14.32]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE ONSURFACE/ EXISTING CABLE TRAY COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 32. 25 Sq mm 4 core (Arm.) [Through Rate] |
| 64 | [24.14.40]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE ONSURFACE/ EXISTING CABLE TRAY COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 40. 35 Sq mm 4 core (Arm.) [Through Rate] |
| 65 | [24.14.48]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE ONSURFACE/ EXISTING CABLE TRAY COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 48. 50 Sq mm 4 core (Arm.) [Through Rate] |
| 66 | [24.14.88]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE ONSURFACE/ EXISTING CABLE TRAY COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 88. 240 Sq mm 3.5 core (Arm.) [Through Rate] |
| 67 | [24.16.2]HT CABLES (Aluminium Conductor, Armoured and Unarmoured) Providing and erection/ laying of XLPE (E) 11 KV HT Aluminium Conductor Armoured Cable ISI Mark Laid in Existing Pipe/Trenches/Surface with all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-In-Charge of the Works 2. Providing and erection/ laying of XLPE (E) 11 KV HT Aluminium Conductor Armoured Cable ISI Mark Laid in Existing Pipe/Trenches/Surface with all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-In-Charge of the Works 50 Sq mm 3 core [Through Rate] |
| 68 | [24.16.4]HT CABLES (Aluminium Conductor, Armoured and Unarmoured) Providing and erection/ laying of XLPE (E) 11 KV HT Aluminium Conductor Armoured Cable ISI Mark Laid in Existing Pipe/Trenches/Surface with all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-In-Charge of the Works 4. Providing and erection/ laying of XLPE (E) 11 KV HT Aluminium Conductor Armoured Cable ISI Mark Laid in Existing Pipe/Trenches/Surface with all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-In-Charge of the Works 95 Sq mm 3 core [Through Rate] |
| 69 | [24.2.9.3]LT CABLE 9.3. Supply and erection of straight through joint (cable jointing kit) 1.1 KV grade complete with required quantity of resin, hardener, plastic mould G.P. Putty, adhesive, earth continuity, connections and fixing the same in position complete with joint etc. - Straight through Joint. For 10 to 16 sqmm Cable 2 Core [Through Rate] |
| 70 | [24.2.9.4]LT CABLE 9.4. Supply and erection of straight through joint (cable jointing kit) 1.1 KV grade complete with required quantity of resin, hardener, plastic mould G.P. Putty, adhesive, earth continuity, connections and fixing the same in position complete with joint etc. - Straight through Joint. For 10 to 16 sqmm Cable 3 to 4 Core [Through Rate] |
| 71 | [24.2.9.5]LT CABLE 9.5. Supply and erection of straight through joint (cable jointing kit) 1.1 KV grade complete with required quantity of resin, hardener, plastic mould G.P. Putty, adhesive, earth continuity, connections and fixing the same in position complete with joint etc. - Straight through Joint. For 25 sqmm to 50 sqmm Cable 3 to 4 Core [Through Rate] |
| 72 | [24.2.9.6]LT CABLE 9.6. Supply and erection of straight through joint (cable jointing kit) 1.1 KV grade complete with required quantity of resin, hardener, plastic mould G.P. Putty, adhesive, earth continuity, connections and fixing the same in position complete with joint etc. - Straight through Joint. For 70 sqmm to 150 sqmm Cable 3 to 4 Core [Through Rate] |
| 73 | [24.2.9.7]LT CABLE 9.7. Supply and erection of straight through joint (cable jointing kit) 1.1 KV grade complete with required quantity of resin, hardener, plastic mould G.P. Putty, adhesive, earth continuity, connections and fixing the same in position complete with joint etc. - Straight through Joint. For 185 sqmm Cable 300 sqmm cable 3 to 4 Core [Through Rate] |
| 74 | [24.3.3.1]HT CABLE 3.1. Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :70 to 120 sqmm [Through Rate] |
| 75 | [24.3.5.2]HT CABLE 5.2. Supplying and making straight through cable jointing with heat shrinkable jointing kit complete with all accessories including ferrules suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :120 to 150 sqmm [Through Rate] |
| 76 | [24.5.1.5]MISCELLANEOUS ITEMS 1.5. Supply and jointing three core submersible flat cables of approved make with bare bunched copper conductor insulated and sheathed with PVC for submersible pump motors /fountain lights etc with voltage grade 1100 volts marked with IS:694, 1990 including cost of jointing, materials as well as carriage, loading, unloading etc. complete in all respect up to the entire satisfaction of Engineer- in-Charge. Submersible Copper Cable 3 Core 10 sqmm [Through Rate] |
| 77 | [24.5.2.3]MISCELLANEOUS ITEMS 2.3. S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Metre below ground level including digging and refilling of earth including cost of suitable size socket/coupler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work. DWC/HDPE pipe 63/50 mm outer dia/inner dia [Through Rate] |
| 78 | [24.5.2.4]MISCELLANEOUS ITEMS 2.4. S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Metre below ground level including digging and refilling of earth including cost of suitable size socket/coupler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work. DWC/HDPE pipe 90/75 mm outer dia/inner dia [Through Rate] |
| 79 | NS PARTSupply and erection of automatic three phase street light controller with time switch operation ON and OFF, setting upto 24 hours, complete with timelite 65 amp. 3 pole 230 V analog time switch contactor and MS power coated enclosure of suitable size. The work will be complete in all respect including making necessary connection, earthing nuts and bolts and other petty material to complete the job. |
| 80 | Supplying and erection of stay set complete (galvanised) with 19/20 mm dia X 1.8 metres long stay rod, anchor plate of size 45 cm X 45 cm X 7.5 mm, thimble, stay clamps, turn buckle ( 20 mm X 60 cm ), 7/ 4.00 mm dia G.I. stay wire and strain insulator etc in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling etc. as required. |
| 81 | Supply and filling of fresh transformer oil complete in all respect including etc. |
| 82 | Supply and filling of Silicone Gel in existing breather of transformer complete in all respect including cost of material and labour etc. |
| 83 | Repairing of HT Copper winding of various capacity Transformer complete in all respect including copper Coils, insulation material, sundry items, labour charges of dismantling of burnt winding, rewinding, assembling Taking, ovening, testing and buy back of burnt/ old winding Scrap etc. HT copper coil of 160 KVA |
| 84 | Repairing of HT Copper winding of various capacity Transformer complete in all respect including copper Coils, insulation material, sundry items, labour charges of dismantling of burnt winding, rewinding, assembling Taking, ovening, testing and buy back of burnt/ old winding Scrap etc. HT copper coil of 200 KVA |
| 85 | Repairing of HT Copper winding of various capacity Transformer complete in all respect including copper Coils, insulation material, sundry items, labour charges of dismantling of burnt winding, rewinding, assembling Taking, ovening, testing and buy back of burnt/ old winding Scrap etc. HT copper coil of 250 KVA |
| 86 | Repairing of HT Copper winding of various capacity Transformer complete in all respect including copper Coils, insulation material, sundry items, labour charges of dismantling of burnt winding, rewinding, assembling Taking, ovening, testing and buy back of burnt/ old winding Scrap etc. HT copper coil of 315 KVA |
| 87 | Repairing of LT Copper winding of various capacity Transformer complete in all respect including copper Coils, insulation material, sundry items, labour charges of dismantling of burnt winding, rewinding, assembling Taking, ovening, testing and buy back of burnt/ old winding Scrap etc. LT copper coil of 160 KVA |
| 88 | Repairing of LT Copper winding of various capacity Transformer complete in all respect including copper Coils, insulation material, sundry items, labour charges of dismantling of burnt winding, rewinding, assembling Taking, ovening, testing and buy back of burnt/ old winding Scrap etc. LT copper coil of 200 KVA |
| 89 | Repairing of LT Copper winding of various capacity Transformer complete in all respect including copper Coils, insulation material, sundry items, labour charges of dismantling of burnt winding, rewinding, assembling Taking, ovening, testing and buy back of burnt/ old winding Scrap etc. LT copper coil of 250 KVA |
| 90 | Repairing of LT Copper winding of various capacity Transformer complete in all respect including copper Coils, insulation material, sundry items, labour charges of dismantling of burnt winding, rewinding, assembling Taking, ovening, testing and buy back of burnt/ old winding Scrap etc. LT copper coil of 315 KVA |
| 91 | Replacement of Silica Gel Breather complete in all Respect including cost of material and labour etc. 100 KVA to 315 KVA Transformer |
| 92 | Replacement of Tap Changer Switch competes in all Respect including cost of material and labour etc. 100 KVA to 315 KVA Transformer |
| 93 | Repairing of LT Panel CRCA Panel Sheet 2.0mm with removing the rusting and welding, hinges, Nuts, Bolts, Washers, Ferule Numbers, Cable Ties, Tie Base, Copper Thimbles, Panel Locks, I-Hooks, PVC Tape, Insulators E-type, L-Type, Round Type, MCB Chanel, PVC Chanel, Connector Chanel, Connectors etc. and complete the work with proper finishing with Epoxy grey color paint complete in all respect as entire satisfaction of engineer in charge. |
| 94 | Supply, installation, testing and commissioning of wall / free standing floor mounting dust and vermin proof compartmentalized cubical panel made out of 2 mm thick CRCA sheet, fabricated at site or fabricated at workshop with required hardware 3-mm thick Bakelite sheet provided all along the bus bar and cable alley separating switches compartment and supporting suitable channel duly painted by 2 coat of Zinc / Red oxide primer followed by 2 coats of powder coating in grey or required shade after rinsing. Complete in all respect as entire satisfaction of engineer in charge. |
| 95 | Servicing and Testing of 50/62.5 KVA D.G Set with Cleaning and lubrication of all moving parts including complete Premium Oil ,lube Oil Filter, Inhibitor Corrosion, Separator Fuel Water, Element Air Filter primary and secondary, V Belt, Fuel Filter Element Primary and secondary, Fuel Pipe etc. complete with handling and services charges and all other petty material to Complete the job in all respect with all labour upto entire satisfaction of EIC of the work. |
| 96 | Servicing and Testing of 125 KVA D.G Set with Cleaning and lubrication of all moving parts including complete Premium Oil ,lube Oil Filter, Inhibitor Corrosion, Separator Fuel Water, Element Air Filter primary and secondary, V Belt, Fuel Filter Element Primary and secondary, Fuel Pipe etc. complete with handling and services charges and all other petty material to Complete the job in all respect with all labour upto entire satisfaction of EIC of the work. |
| 97 | Servicing and Testing of 35/40 KVA D.G Set with Cleaning and lubrication of all moving parts including complete Premium Oil ,lube Oil Filter, Inhibitor Corrosion, Separator Fuel Water, Element Air Filter primary and secondary, V Belt, Fuel Filter Element Primary and secondary, Fuel Pipe etc. complete with handling and services charges and all other petty material to Complete the job in all respect with all labour upto entire satisfaction of EIC of the work. |
| 98 | Supply and fixing of drivers for various electrical luminaries complete in all respect upto the satisfaction of Engineer-In-Charge. 1) 12 Watt-36 Watt downlighter LED/ 2`*2` panel (surface/Recess). |
| 99 | Supply and fixing of drivers for various electrical luminaries complete in all respect upto the satisfaction of Engineer-In-Charge. 1) 45 Watt-60 Watt Street light LED/Flood LED driver. |
| 100 | Supply and fixing of drivers for various electrical luminaries complete in all respect upto the satisfaction of Engineer-In-Charge.1) 100 Watt Flood LED driver |
| 101 | Supply and fixing of drivers for various electrical luminaries complete in all respect upto the satisfaction of Engineer-In-Charge. 1) 200 Watt Flood LED driver |
| 102 | Supply and Erection of Post Top lantern 25 watt suitable for 220 V, 50 Hz supply. Make as per HPHC Brand list |
| 103 | Supply and erection of LED light 2` x 2` 36 Watt, operation on single phase AC supply upto 35000 working hour complete in all respect up to the entire satisfaction of Engineer- in -charge of the work including making necessary connections etc. |
| 104 | Supply and Erection of Commercial Mineral RO system of 50 Liter/ hr. water Purification Capacity i/c fixing on wall with all petty material and labour reqd. operation on single phase AC supply complete in all respect upto the entire satisfaction of Engineer- in -charge of the work including making necessary connections etc. |
| 105 | Supply of Wall Fan 16` Sweep ( 400mm)oscilating pipe light duty complete with built-in regulater, blade, jali etc. Make:- as per HPHC approved Brand List. |
| 106 | Supply and Erection of inverter type Split AC 2 TON (4 STAR) hot and cold operated on 220v 10% single phase 50hz supply condensing unit and indoor unit control panel with 5KVA stabilizer copper winding and AC wall stand and copper pipe upto 3 mtr. etc. complete in all respect. |
| 107 | Supply, installation, testing and commissioning of 1100 mm (nominal size), 20 watt LED batten luminaire in PC housing with minimum light output 100 lumen/watt and Toatl system lumen )2000 lumen THD (20%, PF )0.95. The fixture shall be designed for a system life of 50,000 hours @ 70% lumen maintenance. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters.(as per HPHC Brand list) |
| 108 | Supply, installation, testing and commissioning of 9.6w / mtr led strip with AC to DC Driver, Operating voltage 140-270v, cct 3000k, PF )0.5. The fixture shall be designed for a system life of 30,000 hours. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters. |
| 109 | Supply, Installation, Testing and Commissioning of 1.5 TR, 5 star, Inverter type, Wall mount `Split Air-conditioning unit `, single phase consisting of condensing indoor unit, outdoor unit of copper coil, MS stand, copper wound digital stabilizer 4 KVA , 160V -270V , copper refrigerant piping and cabling between indoor and outdoor unit upto 3 meter etc. complete in all respect i/c making repair of wall, floor and roof in original shape caused by making holes and chases etc. |
| 110 | Supply and erection of 11 Meter PCC pole including excavation and refilling with soil, ramming and compacting in all respect as per DHBVN specifications and upto entire satisfaction of Engineer incharge of the work. |
| 111 | Supplying of 200 W LED Flood light luminaire, housing made up of die cast aluminium/ aluminium alloy, complete with driver, LEDs with Optic Lenses, toughened glass cover and mounting bracket. The fixture should have a minimum system efficacy of 120 lumen/Watt, ingress Protection of IP66 and Mechanical Impact Resistance Rating of IK )=07. The fixture driver should have an operating voltage range of 140-270 V, surge protection of (=10KV, PF) 0.9, THD (10%. The fixture shall be designed for a system life of 50,000 hours @ 70% lumen maintenance. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters |
| 112 | Supply and Erection of 100 watt LED Flood light suitable for operation on 230V ,50Hz complete the job in all respect. |
| 113 | Supply, installation, testing and commissioning of 18 W downlighter Recess mounted complete with Aluminum housing for efficient dissipation and white polycarbonate ring and PC diffuser, LEDs and electronic driver with THD (10%, Output Short Circuit Protection, Surge Voltage Protection. Minimum system efficacy of 100 lumen/Watt, Total Lumen shoud be 1800lumen, Operating voltage range 140 V-270 V and suitable for ceiling cut out 187 mm. The fixture shall be designed for a average LED life L70B50 50000 hours. LM 79 and LM 80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters. |
| 114 | Refrigerant Piping :- Supply installation Testing and Commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for F/VRV system, complete with fittings, with suitable adjustable ring type hanger supports, ng/brazing including accessories insulated with XLPE Class O tubular insulation/with Class O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories.Size 12.70mm OD |
| 115 | Supply and charging of Refrigerant Gas R- 410 for Top up in all respect as per requirement. |
| 116 | Supply and erection of metal exhaust fan, double ball bearing suitable for single phase A.C. 230 Volts, 50 HZ capacitor, 900 RPM (Heavy duty) complete with mounting ring, blade including louver shutter complete with fixing and making necessary connections etc. (i) Size 300 mm sweep |
| 117 | Supply, installation, testing and commissioning of 18 Watt surface mounted LED downlighter Surface mounted complete with Aluminum housing for efficient dissipation and white polycarbonate ring and PC diffuser, with minimum light output 100 lumen/watt THD (10%, PF ) 0.95. The fixture shall be designed for a system life of 50,000 hours @ 70% lumen maintenance. LM 79 and LM 80 reports need to be submitted from a NABL/UL accredited lab to verify above parameter complete with all accessories, electronic driver, diffuser, directly on ceiling/ wall, including connections and earthing etc. as required complete in all respect up to the entire satisfaction of Engineer in Charge. |
| 118 | Supply and Erection of water cooler SP body with 150 ltr /hr and 150 ltr storage capacity with 2 nos of cold faucets ,Reciprocating compressor type condensing tube grooved cooper ,operation on single phase complete with petty material required for connections and labour to compete the job upto entire satisfaction of Engineer-in-Charge of the work. |
| 119 | Supply and Erection of 2200 VA pure sine wave Invertor, square wave technology with power active switch and backup time upto 8 hours suitable for operation on single phase 230 volts, 50 HZ, AC supply, with 2 nos of batteries of 150 AH having warranty of 2 years complete with trolly for batteries (I/c cost of 2 nos batteries and Trolly ) I/c making necessary connections with petty material required to complete the job in all respect upto entire satisfaction of Engineer-in-Charge of the work. |
| 120 | Supply and erection of wall stand Stabilizer 5 KVA ( 100 Up ) copper wound ( 130 Volt to 280 Volt ) complete in all respect. |
| 121 | Supply and erection of Wall Stand Stabilizer 4 KVA ( 100 UP ) copper wound ( 130 Volt to 280 Volt ) complete in all respect. |
| 122 | Supply and Erection of 150 AH Tubular batteries having warranty of 2 years complete with all labour and petty material required for making necessary connections upto entire satisfaction of Engineer-in-Charge of the work. |
| 123 | Supply and erection of 45 Watts LED IP66 street light fitting white colour, pressure die cast aluminium street light luminary, operation on single phase 240 v AC supply with minimum 50000 working hours ,120 Lumens /watt with power factor )0.95 with petty material required for connections to complete the job in all respect up to the entire satisfaction of engineer- in charge of the work . |
| 124 | SITC of premium automatic boom barrier specially designed for high-traffic, secure vehicle entry management at parking lots, gated communities and industrial complexes. Its high-performance motor and robust mechanism support rapid open/close cycles and customizable boom length up to 6 meters. Advanced features include safety sensors for obstacle detection, IP55-rated weatherproof casing, and emergency manual override. integrates seamlessly.Features: - Rebound function in resistance, Quick lifting speed, long remote-control range 30m, Negligible Maintenance, 24V DC Brushless motor, Appearance Dimension 340mm * 272mm * 1000mm, Power Supply 220V ± 10% 50 ~ 60Hz, Voltage AC110V/220V, Motor 24v150w brushless 2-stage variable speed all copper DC motor, Working Environment -15°C ~ plus 70°C, Open Time 6 Sec, Integration Controller, UHF Reader etc. complete in all respect upto the entire satisfaction of the Engineer-in-charge of the work. |
| 125 | 11KV 4 VCB PANEL (1I/C, 3 outgoing)Supply, installation, testing and commissioning of (a.) One No. incoming panel equipped with following: - 630A, 11KV, VCB 25 KA, TP, totally enclosed, air insulated metal clad housing, cassette mounted horizontal isolation, horizontal draw out type, motorized spring charged, manually operated, trip free, vacuum circuit breaker (VCB) having double isolation features and control devices complete with mechanical with continuous tripping and closing, coil suitable for 24V DC, shunt trip coil, OFF/ON indicators, mechanical operation counter and provided with following: Spring charge/ discharge mechanical OFF push buttons for emergency trip (test / service position limit switches with 6 NO/6 NC breaker auxiliary contacts in service position and the cubicle shall be of LSC 2B (Loss of Service Continuity) and PM (Partition Class) classes as defined by IEC standard 62271-200. And it shall comprise three high voltage compartments and one LV cabinet CT chamber with single wound single phase, dual core cast resin CT, 15VA burden with core-1 for metering (CL-1) and core-2 for protection (CL-5P10) and of 150/30/5 plus 5A ratio. Potential Transformer Resin Cast Fix Type with Fuse Ratio 11kV/r3/110V/r3 , 100VA . Microprocessor Based IDMT Relay (ANSI 50-51-50N and 51N), Voltage Controlled Over Current Relay (ANSI-50V), Negative Phase Sequence Relay (ANSI -46), Directional Power Protection Relay (ANSI-32), Circuit Breaker Frailer Protection Relay (ANSI-50BF) , Under impedance protection Relay (ANSI-21), Differential protection Relay (ANSI-87). -1 Set, Anti pumping relay and master trip relay- 1 Set, Digital Ammeter with selector switch. 1 Set Digital Voltmeter with Selector Switch ,1 Set multifunction meter ,1 Set, A set of breaker ON/OFF/Trip/DC control supply/ Spring Charged indication lamp. 1 Set, Emergency trip push button on front door 1 Set, Limit switches with 6 NO/ 6 NC breaker auxiliary contacts 1 Set, Control: - T-N-C (Trip, Neutral, Close) breaker control switch. 1 Set, Space heater with thermostat for moisture absorption. 1 Set, Suitable for connection to 2 Runs x 3 core x 300 sq.mm. Cross linked polyethylene (XLPE) 11KV cables or as called for. 1 Set, HT Danger Plate 1 Set, Hooter low intensity 24 Volt with acknowledge and reset push button 1 Set, 6-window microprocessor-based annunciator panel with audio and visual indicator. Over current and earth fault - 2 windows Master trip operated - 1 window Spare - 3 windows Surge Arrestor, 10KA, Class II1 Set, Thermal monitoring shall be fitted on HV field cable/busbar connections, The monitoring shall be done by a battery less sensor that communicates.(b.) 800A TPN Aluminium busbar made from Electrical Grade. on DMC insulators and covered with heat shrinkable sleeves. c. three No. outgoing panel equipped with following: - 630A, 11KV, VCB 25 KA, TP, totally enclosed, air insulated metal clad housing, cassette mounted horizontal isolation, horizontal draw out type, motorized spring charged, manually operated, trip free, vacuum circuit breaker (VCB) having double isolation features and control devices complete with mechanical with continuous tripping and closing, coil suitable for 24V DC, shunt trip coil, OFF/ON indicators, mechanical operation counter and provided with following: Spring charge/ discharge mechanical OFF push buttons for emergency trip (test / service position limit switches with 6 NO/6 NC breaker auxiliary contacts in service position and the cubicle shall be of LSC 2B (Loss of Service Continuity) and PM (Partition Class) classes as defined by IEC standard 62271-200. And it shall comprise three high voltage compartments and one LV cabinet CT chamber with single wound single phase, dual core cast resin CT, 15VA burden with core-1 for metering (CL-1) and core-2 for protection (CL-5P10) and of 150/30/5 plus 5A ratio. Microprocessor Based IDMT Relay (ANSI 50-51-50N and 51N), Negative Phase Sequence Relay (ANSI -46), Voltage Controlled Over Current Relay (ANSI 52V), Residual Neutral Over Current Relay (ANSI 51NS) ,Under impedance protection Relay (ANSI-21), DC control Supply Failure Relay (ANSI -80), Over Flushing Protection Relay (ANSI - 24), Trip and Trip Free Rely (ANSI-94), Under and Over Voltage Relay (ANSI -27-59) Aux Relay (ANSI -63X) For Oil temperature, winding Temperature. -1 Set, Anti pumping relay and master trip relay- 1 Set, Digital Ammeter with selector switch. 1 Set Digital Voltmeter with Selector Switch ,1 Set multifunction meter. 1 Set, A set of breaker ON/OFF/Trip/DC control supply/ Spring Charged indication lamp. 1 Set, Emergency trip push button on front door 1 Set, Limit switches with 6 NO/ 6 NC breaker auxiliary contacts 1 Set, Control: - T-N-C (Trip, Neutral, Close) breaker control switch. 1 Set, Space heater with thermostat for moisture absorption. 1Set, Suitable for connection to 2 Runs x 3 core x 300 sq.mm. Cross linked polyethylene (XLPE) 11KV cables or as called for. 1 Set, HT Danger Plate 1 Set, Hooter low intensity 24 Volt with acknowledge and reset push button 1 Set, 6-window microprocessor-based annunciator panel with audio and visual indicator. Over current and earth fault - 2 windows Master trip operated - 1 window Spare - 3 windows Surge Arrestor, 10KA, Class II1 Set, Thermal monitoring shall be fitted on HV field cable/busbar connections, The monitoring shall be done by a battery less sensor that communicates. Restricted Earth fault Relay (ANSI -64R)complete in all respect up to the entire satisfaction of Engineer- in - charge of the work including making necessary connections etc. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail