Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | HSR ITEMS- [10.2]Supplying and filling in plinth with sand (conforming to zone-IV, IS 1542) under floors, including watering, ramming, consolidating and dressing complete. [Through Rate] |
| 2 | [10.29.2]Providing and laying of chequered terrazzo tiles 20 to 22 mm thick with graded marble chips of size up to 6 mm in floors, jointed with neat cement slurry mixed with pigment to match the shade of the tiles, including rubbing and polishing complete, on 20 mm thick bed of cement mortar 1:4 (1 cement :4 coarse sand) : 2. Medium shade pigment using 50% white cement, 50% ordinary cement [Through Rate] |
| 3 | [10.5]Providing and laying of screed of 40 mm thick cement concrete 1:8:16 to be laid below the topping. [Through Rate] |
| 4 | [10.50.1]Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. 1. Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. [Through Rate] |
| 5 | [10.51]Providing and fixing granite stone in all shades 15mm to 18 mm thick in skirting /dado, risers of steps, pillars and wall facing, laid in any pattern as specified over base of 12mm thick cement coarse sand mortar 1:3 and jointed with white cement slurry mixed with pigment to match the shade of Granite including labour for fixing cramps pins and dowels etc. [Through Rate] |
| 6 | [10.54.1]Providing and fixing 25 mm wooden planking, tongued and grooved in flooring, including fixing with iron screws complete with : 1. Second class teak wood [Through Rate] |
| 7 | [10.55]providing and fixing 38 mm thick wood block flooring of first class teak wood laid over 25 mm thick levelling layer of cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 10 mm nominal size) to be paid separately, coated with a thin layer of hot bitumen penetration 80/25 (blown type) @ 2.45 kg per sqm, including fixing blocks in position after dipping in hot bitumen (blown type) up to half depth, planed, levelled smooth and finished complete. [Through Rate] |
| 8 | [10.58]Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. [Through Rate] |
| 9 | [10.61]Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including pointing the joints with white cement and matching pigments etc., complete. [Through Rate] |
| 10 | [10.62]Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. [Through Rate] |
| 11 | [10.70.4]Extra for grouting the joints of floor tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. 4. Size of Tile 1000x1000 mm [Through Rate] |
| 12 | [10.71.4]Providing and laying Vitrified tiles in floor with different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS:15622, of approved brand and manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately). 4. Size of Tile 1000x1000 mm [Through Rate] |
| 13 | [10.8]Providing and laying of conglomerate floor 40mm thick cement concrete topping 1:2:4 [Through Rate] |
| 14 | [11.121]Polyurethane polish (PU) two or more coats to give required finish including two coat of wood sealer Including Preparation of surface/base complete as per specification [Through Rate] |
| 15 | [11.13.1]Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement. 1. 12 mm cement plaster [Through Rate] |
| 16 | [11.17]Providing and fixing of chicken wire mesh for avoiding cracks in plaster with necessary nail/screws etc. complete in all respect to the entire satisfaction of engineer-in-charge [Through Rate] |
| 17 | [11.3]Neat cement punning. [Through Rate] |
| 18 | [11.46]Providing and applying 12 mm thick (average) premixed formulated one coat gypsum lightweight plaster having additives and light weight aggregates as vermiculite/ perlite respectively conforming to IS: 2547 (Part - 1 and II) 1976, applied on hacked / uneven background such as bare brick/ block/ RCC work on walls and ceiling at all floors and locations, finished in smooth line and level etc. complete. [Through Rate] |
| 19 | [11.58]Providing and applying two coats white cement based putty of approved brand and manufacturer, over plastered surface and grinding the surface smooth with sand paper to get en even and smooth finish including cost and carriage of all material , labour charges, scaffolding, sundries etc. complete [Through Rate] |
| 20 | [11.64.1]Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : 1. New work (two or more coats) over and including water thinnable priming coat with cement primer [Through Rate] |
| 21 | [11.68.3]Applying priming coat: 3. With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works [Through Rate] |
| 22 | [11.68.4]Applying priming coat: 4. With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel work (second coat) [Through Rate] |
| 23 | [11.73.1]Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer`s specifications including appropriate priming coat, preparation of surface, etc. complete. 1. On steel work [Through Rate] |
| 24 | [11.76]Preparation of ply wood surface for painting including sand papering the surface and applying filling with approved quality filler consisting of white lead, linseed oil, varnish and chalk mitti including finishing the surface to required finish complete. [Through Rate] |
| 25 | [11.77]Applying pink primer or aluminium priming coat on wood work including preparation of surface, Knotting and stopping etc. [Through Rate] |
| 26 | [11.78]Painting two coats excluding priming coat with synthetic enamel paint in all shades on new wood work or metallic or plastered or concrete surfaces to give an even shade. [Through Rate] |
| 27 | [11.95.1]Finishing walls with Acrylic Smooth exterior paint of required shade : 1. New work (Two or more coat applied @ 1.67 litre/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) [Through Rate] |
| 28 | [12.102.1]Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 1. 125 mm [Through Rate] |
| 29 | [12.102.2]Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 2. 100 mm [Through Rate] |
| 30 | [12.103.1]Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. 1. Single rubber stopper [Through Rate] |
| 31 | [12.114]Providing and fixing of roller blinds on windows complete with material and labour complete with push up and down arrangement as per approved design / colour and Engineer-in-charge. [Through Rate] |
| 32 | [12.157.2.2]Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, panelling and dash fasteners to be paid for separately) : 2.2. For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Powder coated aluminium (minimum thickness of powder coating 50 micron) [Through Rate] |
| 33 | [12.159.1]Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): 1. With float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm) [Through Rate] |
| 34 | [12.28.1]Providing and fixing wooden moulded corner beading of triangular shape to the junction of panelling etc. with iron screws, plugs and priming coat on unexposed surface etc. complete 2nd class teak wood. 1. 50x50 mm (base and height) [Through Rate] |
| 35 | [12.31.1]Providing and fixing cup board shutters with 25 mm thick veneered particle board IS : 3097 marked, exterior grade (Grade I), of approved make, including IInd class teak wood lipping of 25 mm wide x 12 mm thick with necessary screws and bright finished stainless steel piano hinges, complete as per direction of Engineer-in-Charge. 1. With decorative veneering on one side and commercial veneering on other side [Through Rate] |
| 36 | [12.33.2]Providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm all complete. 2. With 12 mm mild steel U beading [Through Rate] |
| 37 | [12.36.1]Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 1. 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws [Through Rate] |
| 38 | [12.36.3]Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 3. 25 mm thick (for cupboard) including ISI marked nickel plated bright finished M.S. Piano hinges IS : 3818 marked with necessary screws [Through Rate] |
| 39 | [12.38.1]Extra for Providing and fixing flush doors with decorative veneering instead of non decorative ISI marked flush door shutters conforming to IS: 2202 (Part I) 1. On one side only [Through Rate] |
| 40 | [12.88]Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight up to 35 kg and door width up to 700 mm), with necessary accessories and screws etc. complete. [Through Rate] |
| 41 | [12.98.1]Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : 1. 300x16 mm [Through Rate] |
| 42 | [12.98.2]Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : 2. 250x16 mm [Through Rate] |
| 43 | [12.99.3]Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 3. 200x10 mm [Through Rate] |
| 44 | [12.99.4]Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 4. 150x10 mm [Through Rate] |
| 45 | [12.99.5]Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 5. 100x10 mm [Through Rate] |
| 46 | [13.18]Providing and fixing hard drawn steel wire fabric 75 mm X 25 mm rectangular mesh with 3.25 mm dia wire fixed on steel windows of standard rolled sections with 3 mm thick flat iron cover moulding of 12.5 mm width fixed with machine screws welded complete in all respect. [Through Rate] |
| 47 | [13.21.2]Supply and fixing Windows frames (Chowkhats) including mullions consisting frame fabricated from sheet roll formed out of 1.2mm thick galvanized sheet as per IS:277 (Base steel as per IS 513) with zinc of 120 gm/sqm and Powder coated with pure Polyester powder up to 50 microns (as per approved colour), 3 Nos. 100mm butt - hinges 2mm thick, 6 Nos. 1.2mm thick CRCA electroplated stiffner, 6 Nos. M.S hold fast with split and tail welded to stiffner plate 200mm long, receiver for aldrop, weld less corner assembly with brackets and screws, M.S tie rod 50mm x 25mm to be fixed at bottom finished with powder coated total thickness of coating 0.6mm of approved shade, fixed in position including the cost of cement concrete for 1:2:4 for fixing lugs complete in all respects as per drawing, design, specification and entire satisfaction of Engineer-in-charge. 2. Door Frame of size 125mm x 60mm with 37mm wide double rebate for 35mm door shutter [Through Rate] |
| 48 | [13.3.1.1]Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 2.0 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 2.00 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge: 1.1. Profile B Fixing with adjustable lugs with split end tail to each jamb [Through Rate] |
| 49 | [13.3.3.1]Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 2.0 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 2.00 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge: 3.1. Profile E Fixing with adjustable lugs with split end tail to each jamb [Through Rate] |
| 50 | [13.41]Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories and stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). [Through Rate] |
| 51 | [13.6.1]Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. 1. Using M.S. angels 40x40x6 mm for diagonal braces [Through Rate] |
| 52 | [17.5.3]Compacting Original Ground 3. Compaction of Earthwork Compaction of & preparation of sub grade including loosening, levelling of earth 225 mm thick top layer, rough dressing of soil, final dressing of earth to give level, camber, watering, rolling with road roller, compacting the bed to achieve minimum dry density as given in the Table 3000-2 as per technical clause 305 of MORT&H specifications [Through Rate] |
| 53 | [17.73]Construction of unreinforced plain cement concrete pavement in M-25 mix design over a prepared sub base with OPC 43 grade conforming to IS:383 mixed with concrete mixer using batch type concrete mixer as per IS:1791, laid in position, compacted with needle vibrator, screed vibrator and plate vibrator, dewatering of free water with vaccum pump, finishing the surface with power floater, finishing to required lines and grades as per drawings and technical clause 1501 of MORTH specifications [Through Rate] |
| 54 | [18.8]Providing and fixing in position Phenol bonded Bamboo wood in wall skirting with planks of sizes 14mm thick, 1900mm length (minimum) and 85mm wide(minimum), in approved colour, texture and finish, having Performance Appraisal Certificate (PAC) issued by Building Materials and Technology Promotion Council (BMTPC). The skirting shall be fixed with SS screws and rawl plugs, over underlayment of 4mm thick, expanded polyethylene foam sheets having 40kg/cum density over prepared surface. The bamboo wood planks shall have minimum density of 1000kg/cum and minimum Hardness 1000 kgf. with Eco friendly UV coating, all complete as per direction of the Engineer in-charge. [Through Rate] |
| 55 | [20.26.1]Cutting holes up to 23 cm through stone masonry or brick work in cement walls for pipes and making good including repointing, replastering and finishing according to existing finish where required. 1. 11.43 cm thick wall [Through Rate] |
| 56 | [20.26.2]Cutting holes up to 23 cm through stone masonry or brick work in cement walls for pipes and making good including repointing, replastering and finishing according to existing finish where required. 2. 22.86 cm thick wall [Through Rate] |
| 57 | [21.100.2]Making holes for HCL soil / Waste pipe by core cutting up to 200 mm thick slabs and sealing with Drip seal sealant complete in all respect. 2. 100 mm dia pipe [Through Rate] |
| 58 | [21.84.3]Constructing brick masonry inspection Chamber sizes as given below up to 0.60 metre average depth in cement mortar 1:5 lime concrete with 40 per cent lime mortar 2:3 in foundation cement concrete 1:2:4 benching 12mm thick cement plaster 1:2 with a floating coat of 1 mm thick of neat cement R.C.C. 1:2:4 slab 100 mm thick/cement concrete topping, 50mm thick with 455mmx455mm / 455mm x610mm inside light duty C.I. inspection chamber cover and frame weight as per I.S.I. specification painted with 3 coats of black bitumastic superior paint complete as per standard design. 3. Size 600 mm X900 mm inside (with 455 mm x 455 mm cover and frame light duty single seal weighing 20 kg with R.C.C. slab) [Through Rate] |
| 59 | [21.93.2]Providing and fixing SFRC MANHOLE COVERS AND FRAMES MARKED WITH IS: 12592 including setting the same to correct lines and levels in 1:3 cement sand mortar over manhole including carriage loading unloading stacking handling re-handling etc. complete in all respects to the satisfaction to the Engineer-in-charge. 2. Type:- Extra Heavy Duty Set (EHD-20) 560MM Clear Opening [Through Rate] |
| 60 | [21.94.2]Providing salt glazed stone ware pipes grade ‘A’ in standard length of 600 mm each pipe marked with IS: 651 and their lowering, cutting, jointing and testing as described in item No. 21.38, 21.39, item 21.40 including the cost of jointing materials as well as carriage, loading, unloading, stacking, handling, re-handling etc. complete in all respects to the satisfaction of Engineer-in-charge. 2. 150mm i/d [Through Rate] |
| 61 | [22.1.2]Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: 2. White vitreous chinaware Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap [Through Rate] |
| 62 | [22.10.1.1]Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : 1.1. Kitchen sink with drain board 510x1040 mm bowl depth 250 mm [Through Rate] |
| 63 | [22.101.2.2]Providing and fixing Unplasticised PVC connection pipe with brass unions : 2.2. 45 cm length 20 mm nominal bore [Through Rate] |
| 64 | [22.103.3]Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 3. 25 mm nominal bore [Through Rate] |
| 65 | [22.104.1]Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : 1. 15 mm nominal bore [Through Rate] |
| 66 | [22.106.1]Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 1. 15 mm nominal bore [Through Rate] |
| 67 | [22.107.1]Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. 1. 15 mm nominal bore [Through Rate] |
| 68 | [22.108.1]Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 1. 15mm nominal bore [Through Rate] |
| 69 | [22.109]Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge. [Through Rate] |
| 70 | [22.117]Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. [Through Rate] |
| 71 | [22.119.2]Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 2. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. [Through Rate] |
| 72 | [22.127]Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms. [Through Rate] |
| 73 | [22.14.2.2]Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. 2.2. Flexible pipe 40 mm dia [Through Rate] |
| 74 | [22.15]Providing and fixing CP Brass 32mm size Bottle Trap of approved quality and make and as per the direction of Engineer-in-charge. [Through Rate] |
| 75 | [22.163.4]Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete : 4. 250 mm diameter [Through Rate] |
| 76 | [22.164.3]Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design : 3. 200 mm diameter S.W. pipe [Through Rate] |
| 77 | [22.166.3.2]Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: 3.2. 180x150 mm size P type With Sewer bricks conforming to IS : 4885 [Through Rate] |
| 78 | [22.173.1]Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design : 1. With common burnt clay non-modular bricks of class designation 7.5 [Through Rate] |
| 79 | [22.181]Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. [Through Rate] |
| 80 | [22.190.2.1]Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (Zone-III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : 2.1. Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (medium duty) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg (weight of cover 58 kg and weight of frame 58 kg) : With common burnt clay non-modular bricks of class designation 7.5 [Through Rate] |
| 81 | [22.191.2.1]Extra for depth for manholes : 2.1. Size 120x90 cm With common burnt clay non-modular bricks of class designation 7.5 [Through Rate] |
| 82 | [22.209]Providing and fixing 600x450 mm bevelled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. [Through Rate] |
| 83 | [22.219.4]Lowering, Laying and jointing of class SN 8 structured wall (External Annular Corrugated and Smooth Internal Surface Polyethylene Piping and fitting with the help of coupler(online/ offline) attached with one end of pipes, sliding over the elastomeric sealing rubber ring placed on the specified valley of the corrugation at the spigot end, lowering the same into the trench, laying on the lower bedding (constructed at bottom of trenches) at prescribed gradient, depth and alignment, testing the water tightness of the joints, ensuring the continuity tests of specified pipe segment etc. complete as per drawing, specification and detailed engineering, including cartage of pipes and fitting etc. as per direction of Engineer-in-charge. 4. 500 mm Internal Diameter [Through Rate] |
| 84 | [22.222.1.2]Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. 1.2. Single Socket Type A 110mm o/d SWR UPVC pipe lines laid complete [Through Rate] |
| 85 | [22.222.2.2]Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. 2.2. Single Socket Type B 110mm o/d SWR UPVC pipe lines laid complete [Through Rate] |
| 86 | [22.222.2.3]Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. 2.3. Single Socket Type B 90mm o/d SWR UPVC pipe lines laid complete [Through Rate] |
| 87 | [22.33]Providing and fixing white vitreous chinaware extended wall mounting water closet of size 780x370x690 mm of approved shape including providing and fixing white vitreous chinaware cistern / PVC cistern (with brass fitting) into the wall with dual flush fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete. [Through Rate] |
| 88 | [22.38]Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube up to 1 metre long with S.S. triangular plate to European type W.C. of quality and make as approved by Engineer - in - charge. [Through Rate] |
| 89 | [22.42.1]Providing and fixing toilet paper holder : 1. C.P. brass [Through Rate] |
| 90 | [22.46]Providing and fixing white vitreous chinaware battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre and post flushing with water (250 ml and 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-charge. [Through Rate] |
| 91 | [22.5]Providing and fixing white vitreous chinaware pedestal for wash basin completely recessed at the back for the reception of pipes and fittings. [Through Rate] |
| 92 | [22.8.2]Providing and fixing 15 mm C.P. brass Laboratory cock swan neck of best quality (to the approval of Engineer-in-charge). 2. Two way [Through Rate] |
| 93 | [22.85.4]Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 4. 32 mm nominal outer dia Pipes [Through Rate] |
| 94 | [22.85.5]Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 5. 40 mm nominal outer dia Pipes [Through Rate] |
| 95 | [22.86.2]Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 2. 20 mm nominal outer dia Pipes [Through Rate] |
| 96 | [22.86.3]Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 3. 25 mm nominal outer dia Pipes [Through Rate] |
| 97 | [22.87.5]Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings This includes jointing of pipes and fittings with one step CPVC solvent cement, trenching, refilling and testing of joints complete as per direction of Engineer in Charge. External work 5. 40 mm nominal outer dia Pipes [Through Rate] |
| 98 | [22.98.3]Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 3. 32 mm nominal bore. [Through Rate] |
| 99 | [22.98.4]Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 4. 40 mm nominal bore [Through Rate] |
| 100 | [23.22.1.9]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.9. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. 4 pole MCCB 6 amp to 100 amp , 25 KA [Through Rate] |
| 101 | [23.22.2.1]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 2.1. MCCB Enclosure made of Sheet Steel suitable for mounting MCCB of following ratings MCCB up to 125 A FP [Through Rate] |
| 102 | [23.22.4.1]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 4.1. Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. SPN DB Double Door 4 way ( 2 incoming and 2 outgoing) [Through Rate] |
| 103 | [23.22.4.11]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 4.11. Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. Vertical TPN DB Double Door 8 way ( 8 incoming 3phase*8 outgoing) [Through Rate] |
| 104 | [23.22.4.2]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 4.2. Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. SPN DB Double Door 8 way ( 2 incoming and 6 outgoing) [Through Rate] |
| 105 | [23.22.4.7]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 4.7. Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. TPN DB Horizontal type Double Door 8 way ( 8 incoming 3phase*8 outgoing) [Through Rate] |
| 106 | [23.22.5.1]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.1. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 6 amp. to 32 amp Single Pole [Through Rate] |
| 107 | [23.22.5.4]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.4. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 40 amp to 63 amp. Double pole [Through Rate] |
| 108 | [23.22.5.6]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.6. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 40 amp to 63 amp. MCBs TRIPLE POLE [Through Rate] |
| 109 | [23.22.5.8]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.8. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 40 amp to 63 amp. MCBs FOUR POLE [Through Rate] |
| 110 | [23.22.7]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 7. Supply and erection of blanking sheet in existing distribution board. [Through Rate] |
| 111 | [23.22.8.3]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 8.3. SITC Four pole ON LOAD Manual change over switch in SS enclosure of following Ratings 200 amp 415 volts [Through Rate] |
| 112 | [23.23.1.3]MISCELLANEOUS 1.3. Supply and fixing Galvanised Iron flexible pipe complete with socket nipples and check nuts etc. at both ends (Up to length of one metre):- Size 25 mm dia [Through Rate] |
| 113 | [23.23.10]MISCELLANEOUS 10. Supplying and drawing of 1 no UTP 4 pair CAT 6a LAN Cable in the existing surface/recess MS/PVC conduit as required [Through Rate] |
| 114 | [23.23.2.1]MISCELLANEOUS 2.1. Supply of GI pipe (B-Class) for suspension rod of ceiling fan including threading if required. 15 mm dia [Through Rate] |
| 115 | [23.23.4]MISCELLANEOUS 4. Providing and fixing fan hook made from 8 mm dia MS rod 75 cm long of required shape and size [Through Rate] |
| 116 | [23.23.5.1]MISCELLANEOUS 5.1. Supply and erection of U- PVC Trunking/Channel of following size including cost of fixing on wall, floor and ceiling etc. with required material complete the job in all respect up to entire satisfaction of the Engineer-in-charge of work. 25x12 mm [Through Rate] |
| 117 | [23.23.5.4]MISCELLANEOUS 5.4. Supply and erection of U- PVC Trunking/Channel of following size including cost of fixing on wall, floor and ceiling etc. with required material complete the job in all respect up to entire satisfaction of the Engineer-in-charge of work. 50x50 mm [Through Rate] |
| 118 | [23.23.8.1]MISCELLANEOUS 8.1. Supply and laying of multicore telephone cable conductor size 0.51 mm bright annealed copper conductor PVC insulated and sealed in existing pipe/channel and making necessary connection complete in all respect up to the entire satisfaction of the Engineer-in charge of the work. 2 pair telephone wire [Through Rate] |
| 119 | [23.26.1]SAFETY ITEMS 1. Supply and erection of Medium Voltage caution notice plate of size 200*150 mm in three languages. [Through Rate] |
| 120 | [23.26.4]SAFETY ITEMS 4. Supply & Erection of mild steel bucket stand suitable for 6 Nos. fire buckets,(but without bucket) including the cost of welding and painting of complete stand will one coat of red oxide and 2 coats of approved paint of red colour with all labour and material required to complete the job in all respect up to the entire Satisfaction engineer in charge of the work (size 6x4 made of GI pipe 32mm dia). [Through Rate] |
| 121 | [23.4.1.3]COPPER WIRING WITH MODULAR SWITCHES IN PVC CONDUIT (SURFACE/RECESS) 1.3. Wiring for Light/Fan/call bell point with modular type switch/socket and GI box, Modular type face plate etc in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick PVC conduit pipe. Group C [Through Rate] |
| 122 | [23.4.2.3]COPPER WIRING WITH MODULAR SWITCHES IN PVC CONDUIT (SURFACE/RECESS) 2.3. Wiring for Twin control light point with 2 nos , 2-ways, 5 amp. Modular switch GI box and modular face plate in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick PVC conduit pipe. Group C [Through Rate] |
| 123 | [23.4.4.3]COPPER WIRING WITH MODULAR SWITCHES IN PVC CONDUIT (SURFACE/RECESS) 4.3. Wiring in PVC conduit system for 3-pin 5amp. Plug point by using 2 no 1.5 sqmm FRLS copper wire and 1 no 1.5 Sqmm FRLS copper wire , including providing 1 no 5/6 Amp 3/5 pin Modular type socket and 1 no 5/6 Amp Modular type switch required GI Box ,modular face plate etc complete as required Group C [Through Rate] |
| 124 | [23.4.5.3]COPPER WIRING WITH MODULAR SWITCHES IN PVC CONDUIT (SURFACE/RECESS) 5.3. Wiring in PVC conduit system for 3-pin 15amp. Plug point by using 2 no 4 sqmm FRLS copper wire and 1 no 4 Sqmm FRLS copper wire for earthling , including providing 1 no 15/16 Amp 3/6 pin Modular socket and 1 no 15/16 Amp Modular switch required GI Box , modular face plate etc complete as required Group C [Through Rate] |
| 125 | [23.5.6.1]COPPER WIRING IN EXISTING PVC/MS CONDUIT PIPE SURFACE/RECESSED FOR ELECTRICAL POINTS 6.1. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in existing MS/PVC Conduit etc as required. 1 run of Size 1.50 Sqmm(1/1.40mm) [Through Rate] |
| 126 | [23.5.6.3]COPPER WIRING IN EXISTING PVC/MS CONDUIT PIPE SURFACE/RECESSED FOR ELECTRICAL POINTS 6.3. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in existing MS/PVC Conduit etc as required. 1 run of Size 4 Sqmm(1/2.24mm) [Through Rate] |
| 127 | [23.5.6.4]COPPER WIRING IN EXISTING PVC/MS CONDUIT PIPE SURFACE/RECESSED FOR ELECTRICAL POINTS 6.4. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in existing MS/PVC Conduit etc as required. 1 run of Size 6 Sqmm(1/2.80mm) [Through Rate] |
| 128 | [23.5.6.5]COPPER WIRING IN EXISTING PVC/MS CONDUIT PIPE SURFACE/RECESSED FOR ELECTRICAL POINTS 6.5. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in existing MS/PVC Conduit etc as required. 1 run of Size 10 Sqmm(1/3.50 mm) [Through Rate] |
| 129 | [23.7.6.1]PVC CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS 6.1. Supply and erection of PVC CONDUIT ISI marked (Medium) recessed in wall/ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC pipe of 20 mm dia. [Through Rate] |
| 130 | [23.7.6.2]PVC CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS 6.2. Supply and erection of PVC CONDUIT ISI marked (Medium) recessed in wall/ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC pipe of 25 mm dia. [Through Rate] |
| 131 | [23.7.6.3]PVC CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS 6.3. Supply and erection of PVC CONDUIT ISI marked (Medium) recessed in wall/ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC pipe of 32 mm dia. [Through Rate] |
| 132 | [23.7.6.4]PVC CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS 6.4. Supply and erection of PVC CONDUIT ISI marked (Medium) recessed in wall/ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC pipe of 40 mm dia. [Through Rate] |
| 133 | [23.8.1.12]FITTING AND ACCESSORIES 1.12. Providing and fixing Piano type accessories of approved make in existing box and Bakelite sheet including fixing and making necessary connections, complete in all respect. Bakelite angle/straight button holder large size. [Through Rate] |
| 134 | [23.8.1.5]FITTING AND ACCESSORIES 1.5. Providing and fixing Piano type accessories of approved make in existing box and Bakelite sheet including fixing and making necessary connections, complete in all respect. Ceiling rose flush/surface type [Through Rate] |
| 135 | [23.8.1.6]FITTING AND ACCESSORIES 1.6. Providing and fixing Piano type accessories of approved make in existing box and Bakelite sheet including fixing and making necessary connections, complete in all respect. Call bell 220/230 volts musical type [Through Rate] |
| 136 | [23.8.10.1]FITTING AND ACCESSORIES 10.1. Providing and fixing GI concealed sheet metal boxes with inner and outer face plate including concealing the box in wall and fixing in position with inner plate and face plate with all labour and material required for the job complete in all respects. 1 & 2 Modules including combined plate for Telephone and data [Through Rate] |
| 137 | [23.8.10.2]FITTING AND ACCESSORIES 10.2. Providing and fixing GI concealed sheet metal boxes with inner and outer face plate including concealing the box in wall and fixing in position with inner plate and face plate with all labour and material required for the job complete in all respects. 3 Modules [Through Rate] |
| 138 | [23.8.10.3]FITTING AND ACCESSORIES 10.3. Providing and fixing GI concealed sheet metal boxes with inner and outer face plate including concealing the box in wall and fixing in position with inner plate and face plate with all labour and material required for the job complete in all respects. 4 Modules [Through Rate] |
| 139 | [23.8.10.4]FITTING AND ACCESSORIES 10.4. Providing and fixing GI concealed sheet metal boxes with inner and outer face plate including concealing the box in wall and fixing in position with inner plate and face plate with all labour and material required for the job complete in all respects. 6 Modules [Through Rate] |
| 140 | [23.8.11.10]FITTING AND ACCESSORIES 11.10. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. Blanking plate [Through Rate] |
| 141 | [23.8.11.11]FITTING AND ACCESSORIES 11.11. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. RJ 45 Computer DATA socket outlet for CAT 6 or CAT6e cable Modular type [Through Rate] |
| 142 | [23.8.11.12]FITTING AND ACCESSORIES 11.12. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. USB Charger, 1000mA, 5V, 1 Module ( For Non residential use only) [Through Rate] |
| 143 | [23.8.11.3]FITTING AND ACCESSORIES 11.3. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. 15 amp 1 way switch [Through Rate] |
| 144 | [23.8.11.5]FITTING AND ACCESSORIES 11.5. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. 15 amp 6 pin Socket [Through Rate] |
| 145 | [23.8.11.7]FITTING AND ACCESSORIES 11.7. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. step type Fan Regulator 2 modules 300 watt [Through Rate] |
| 146 | [23.8.11.8]FITTING AND ACCESSORIES 11.8. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. Telephone Socket outlet modular type [Through Rate] |
| 147 | [23.8.11.9]FITTING AND ACCESSORIES 11.9. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. T.V. Socket outlet modular type [Through Rate] |
| 148 | [23.8.12]FITTING AND ACCESSORIES 12. Supply and Fixing 3 mm thick Bakelite sheet cover on existing MS/PVC junction box/tee etc including fixing with brass screws and washers. [Through Rate] |
| 149 | [23.8.2.1]FITTING AND ACCESSORIES 2.1. Supply and Fixing Bakelite sheet on existing MS/GI/wooden/PVC box etc including fixing with brass screws and washers. 5 mm thick [Through Rate] |
| 150 | [23.8.2.2]FITTING AND ACCESSORIES 2.2. Supply and Fixing Bakelite sheet on existing MS/GI/wooden/PVC box etc including fixing with brass screws and washers. 3 mm thick [Through Rate] |
| 151 | [23.8.3.2]FITTING AND ACCESSORIES 3.2. Supply and erection of suitable MS/GI Box covered with 5 mm thick Bakelite sheet as below 100 mm x 100 mm x 60 mm deep M.S. box [Through Rate] |
| 152 | [23.8.4]FITTING AND ACCESSORIES 4. Supply and erection of 10.5 cm dia M.S.Fan box including 8 mm dia 30 cm long M.S. Road made into suitable suspension hook and erected in R.C.C. slab for the erection of fan complete with all labour and material required to complete the job. [Through Rate] |
| 153 | [24.1.1]EARTHING AND LIGHTENING ARRESTOR 1. Earthing with GL earth pipe 4.5 m long and 40 mm dia with masonry enclosures on the top etc. (but without charcoal or coke and salt) as required. [Through Rate] |
| 154 | [24.1.10]EARTHING AND LIGHTENING ARRESTOR 10. Providing and fixing 25 mm x 5mm copper strip on surface or in recess for connections etc. as required with all labour and material. [Through Rate] |
| 155 | [24.1.13]EARTHING AND LIGHTENING ARRESTOR 13. Providing and fixing 4.00 mm dia G1. Wire on surface or in recess for loop earthing as required. [Through Rate] |
| 156 | [24.1.14]EARTHING AND LIGHTENING ARRESTOR 14. Supply and erection of 20mm x 3 mm thick GI, tape fixed with suitable G.I. staples of same size. [Through Rate] |
| 157 | [24.1.2]EARTHING AND LIGHTENING ARRESTOR 2. Extra for using salt and char coal/coke for pipe earth electrode as required. [Through Rate] |
| 158 | [24.1.3]EARTHING AND LIGHTENING ARRESTOR 3. Earthing with G.I. earth plate 600 mmx 600 mm x 6 mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt) complete as required. [Through Rate] |
| 159 | [24.1.4]EARTHING AND LIGHTENING ARRESTOR 4. Earthing with tinned copper earth plate 600mmx600mmx3mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt) etc. complete as required. [Through Rate] |
| 160 | [24.1.5]EARTHING AND LIGHTENING ARRESTOR 5. Extra for charcoal or coke and salt for G.I. plate or copper plate earth electrode. [Through Rate] |
| 161 | [24.1.7]EARTHING AND LIGHTENING ARRESTOR 7. Supplying and laying 25mm x 3 mm G.I. strip in 40 mm dia,GI pipe as/from earth electrode including soldering etc. as required. [Through Rate] |
| 162 | [24.1.8]EARTHING AND LIGHTENING ARRESTOR 8. Providing and fixing 25 mm x 3mm G.I. strip on surface or in recess for connections etc. as required with all labour and material. [Through Rate] |
| 163 | [24.1.9]EARTHING AND LIGHTENING ARRESTOR 9. Providing and fixing 25 mm x5 mm copper strip in 40 mm dia G.I. pipe from earth electrode as required. [Through Rate] |
| 164 | [24.13.24]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 24. 16 Sq mm 4 core (Arm.) [Through Rate] |
| 165 | [24.13.40]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 40. 35 Sq mm 4 core (Arm.) [Through Rate] |
| 166 | [24.13.48]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 48. 50 Sq mm 4 core (Arm.) [Through Rate] |
| 167 | [24.13.56]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 56. 70 Sq mm 4 core (Arm.) [Through Rate] |
| 168 | [24.14.100]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE ONSURFACE/ EXISTING CABLE TRAY COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 100. 400 Sq mm 3.5 core (Arm.) [Through Rate] |
| 169 | [24.14.38]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE ONSURFACE/ EXISTING CABLE TRAY COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 38. 35 Sq mm 3.5 core (Arm.) [Through Rate] |
| 170 | [24.14.94]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE ONSURFACE/ EXISTING CABLE TRAY COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 94. 300 Sq mm 3.5 core (Arm.) [Through Rate] |
| 171 | [24.2.6.4]LT CABLE 6.4. Supply and erection of copper lugs including crimping etc. entire satisfaction of Engineer-in- Charge of the work. 6 sqmm [Through Rate] |
| 172 | [24.2.6.5]LT CABLE 6.5. Supply and erection of copper lugs including crimping etc. entire satisfaction of Engineer-in- Charge of the work. 10 sqmm [Through Rate] |
| 173 | [24.2.7.2]LT CABLE 7.2. Supply and erection of suitable compression type brass cable glands for underground Cable :- 10 sqmm to 16 sqmm Cable 2 to 4 Core [Through Rate] |
| 174 | [24.2.7.3]LT CABLE 7.3. Supply and erection of suitable compression type brass cable glands for underground Cable :- 25 sqmm to 50 sqmm Cable 2 to 4 Core [Through Rate] |
| 175 | [24.2.7.4]LT CABLE 7.4. Supply and erection of suitable compression type brass cable glands for underground Cable :- 70 sqmm to 95 sqmm Cable 3 to 3½ Core [Through Rate] |
| 176 | [24.2.7.7]LT CABLE 7.7. Supply and erection of suitable compression type brass cable glands for underground Cable :- 300 sqmm to 400 sqmm Cable 3 to 3½ Core [Through Rate] |
| 177 | [24.2.8.14]LT CABLE 8.14. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work.300 sqmm [Through Rate] |
| 178 | [24.2.8.15]LT CABLE 8.15. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 400 sqmm [Through Rate] |
| 179 | [24.2.8.4]LT CABLE 8.4. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 16 sqmm [Through Rate] |
| 180 | [24.2.8.6]LT CABLE 8.6. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 35 sqmm [Through Rate] |
| 181 | [24.2.8.7]LT CABLE 8.7. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 50 sqmm [Through Rate] |
| 182 | [24.2.8.8]LT CABLE 8.8. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 70 sqmm [Through Rate] |
| 183 | [24.4.5]STREET LIGHT 5. Supply and erection of Single Phase weather proof M.S. box of size 20 cm x 15 cm x 10 cm with hinged cover made of 2 mm thick MS sheet, locking arrangements, housed in wall/fixed on pole , including the cost of 1 no 4 way 16 A Bakelite connector, 1 no. 6 amp SP MCB and 1 Nos. 16 amp. neutral links fixed on Bakelite sheet in the M.S. box including painting and necessary connections. [Through Rate] |
| 184 | [24.4.8.5]STREET LIGHT 8.5. Supply and erection of Hot Dip Galvanized octagonal pole of 3mm thickness, with base plate including cost of nut and bolts , earthing studs, Integral Cable termination arrangement 5 mm thick Bakelite base plate on suitable welded MS/GI bracket 32 A four way connector 2 no 10 A SP MCB , end cover and all accessories as supplied by the manufacture including Providing RCC foundation of M25 grade (1 Cement:1 Stone aggregate: 2 Coarse sand) i/c excavation, steel reinforcement (Fe 500) @80 kg/cum of concrete contents, concrete cover 50mm, anchor bolts etc. over a bed of PCC 1:5:10 of required dimensions for octagonal poles of various heights as per following specifications complete in all respects and as per directions of Engineer-in-charge 7 Metre Long pole with top dia 75 0mm and bottom dia 150 mm with base plate of size 300 x 300 x 20 mm [Through Rate] |
| 185 | [24.5.2.3]MISCELLANEOUS ITEMS 2.3. S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Metre below ground level including digging and refilling of earth including cost of suitable size socket/coupler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work. DWC/HDPE pipe 63/50 mm outer dia/inner dia [Through Rate] |
| 186 | [24.5.2.5]MISCELLANEOUS ITEMS 2.5. S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Metre below ground level including digging and refilling of earth including cost of suitable size socket/coupler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work. DWC/HDPE pipe 120/105 mm outer dia/ inner dia [Through Rate] |
| 187 | [24.5.2.6]MISCELLANEOUS ITEMS 2.6. S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Metre below ground level including digging and refilling of earth including cost of suitable size socket/coupler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work. DWC/HDPE pipe 145/123 mm outer dia/ inner dia [Through Rate] |
| 188 | [24.7.1]RCC FOUNDATIONS FOR DG SET 1. 30 to 40 KVA DG Set [Through Rate] |
| 189 | [25.1.10]Supplying, fixing, testing and commissioning of condenser water pipes / non insulated chilled water pipes of following sizes of MS C class along with necessary clamps, vibration isolators and fittings such as bends, tees etc. but excluding valves, strainers, gauges etc. adequately supported on rigid supports duly painted/buried in ground excavation and refilling etc. as per specification and as required complete in all respect. 10. 40mm dia. [Through Rate] |
| 190 | [25.1.6]Supplying, fixing, testing and commissioning of condenser water pipes / non insulated chilled water pipes of following sizes of MS C class along with necessary clamps, vibration isolators and fittings such as bends, tees etc. but excluding valves, strainers, gauges etc. adequately supported on rigid supports duly painted/buried in ground excavation and refilling etc. as per specification and as required complete in all respect. 6. 100mm dia. [Through Rate] |
| 191 | [25.1.7]Supplying, fixing, testing and commissioning of condenser water pipes / non insulated chilled water pipes of following sizes of MS C class along with necessary clamps, vibration isolators and fittings such as bends, tees etc. but excluding valves, strainers, gauges etc. adequately supported on rigid supports duly painted/buried in ground excavation and refilling etc. as per specification and as required complete in all respect. 7. 80mm dia. [Through Rate] |
| 192 | [25.3.6]Supplying, fixing, testing and commissioning of Butterfly valves PN 16 rated without insulation for water circulation as per specifications. 6. 100mm dia. [Through Rate] |
| 193 | [25.4.4]Supplying, fixing, testing and commissioning o NON - RETURN VALVE with dual plate of C I body SS plates vulcanized NBR seal flanged end and PN 16 pressure rating as specified. 4. 100mm dia. [Through Rate] |
| 194 | [26.20]Supply and Planting rare and specimen tree plants in already prepared pits (Ficus starlight 150 cm height , Terminalia 210 cm height, menatalis , Michelia champaca hybrid more than 180 cm height, Cyprus (Golden juniperous ) more than 180 cm height, topiary of 10 to 12 no. well trimmed bolls of more than 30cm size of Ficus nuda, Ficus retusa, Ficus long island , Ficus panda more than 180 cm height, Golden bottle brush , casurina equistefolia , Bottle palm with stem circumference at base more than 40cm ,Washingtonia palm of healthy clear stem height below leaf more Thant 90 cm ) including , fertilizer and insecticides chlorpyriphos 20 ml per pit, planting of 180cm to 210cm tall sapling in position and flooding with water .specie of plant will be decided by engineer in charge. [Through Rate] |
| 195 | [26.32]Planting permanent edging plants around beds, lawn or along paths including of digging of trench 45 cm wide to 15 cm depth, refilling the excavated earth, mixed with farm-yard manure, supplied at the rate of 0.9 cum per sqm and supplying and planting hedge/ edge at 20 cm apart in one or two rows @11no. well trimmed bushy ,multi branched ,30 cm to 45 cm in height plants to be supplied in 15 cm x 15 cm poly bags per sqm . [Through Rate] |
| 196 | [26.4.2]SITE CLEARANCE 2. Surface dressing of ground including removing rank vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m in all kind of soils . [Through Rate] |
| 197 | [26.44.2]Supplying and display indoor decorative plants with fresh foliage,60cm-75 cm in height` 3-4 stems per pot, full of leaves, suitable for earthen pots / plastic pots size 30cm dia and 30cm deep(average size),and displaying indoor including the cost of material ( garden soil, coco peat, FYM in2:1:1 proportion),with ,PVC plate. complete in all respects including cost of pot . 2. In Earthen Pot [Through Rate] |
| 198 | [26.45]Maintenance of indoor potted plants for one year including watering, application of fertilizer NPK 20:20:20 @20 gm ,and vermi compost 50 gm , manure, snowcem/ apex every month, replacement of pot plate, broken pot, dead plant with same specie of plant etc. [Through Rate] |
| 199 | [26.50]Supplying and display of specimen pot plant of Cyprus , Ficus starlight, Topiary of Ficus retusa and similar high quality plants in 45 cm cement pots with plastic plate for outdoor display at site of work. with fresh foliage,105 cm- 150 cm in height, 3-4 stems per pot, full of leaves, ,and displaying indoor including the cost of material ( garden soil, coco peat, FYM in 2:1:1 proportion),with ,PVC plate. complete in all respects. [Through Rate] |
| 200 | [26.9.1]Turfing lawns with fine grassing ( selection no.1/ Bermuda and Mexican/Neelgiri grass )including ploughing, dressing including breaking of clods, removal of rubbish, dressing and supplying of selection no. 1 / Bermuda doob grass and Mexican/Neelgiri grass roots, including supplying and spreading of farmyard manure at the rate of 0.60 cum per 100 sqm, maintenance till weed free turf is formed 1. Planting selection no. 1 grass roots in rows 5 cm apart in both directions . [Through Rate] |
| 201 | [28.15]Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. [Through Rate] |
| 202 | [28.50]Providing and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) ) 78, solar reflection ) 0.70 and initial emittance ) 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement and marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm height along the parapet walls in the same manner. [Through Rate] |
| 203 | [28.6]`Providing and applying waterproofing treatment to sound, moisture free concrete surface using liquid applied single component pitch free polyurethane coating capable of bridging substrate cracks up to 2 mm. It shall be applied in two coats at coverage rate of 2kg/sqm to a achieve a minimum DFT of 1.3 mm. The membrane formed shall confirm to following minimum properties:1) Elongation : )400% as per ASTM D 4122) Tensile Strength : 2.5 N/mm2 as per ASTM D 4123) Adhesion in-peel test : )50 N as per ASTM C- 8364) Recovery from 350% elongation : 95% as per ASTM D 4125) Water Vapour Transmission 2.3mm film: 0.6 g/m2/hr6) Initial Hardness Shore A : min 60 as per ASTM D 2240 7) Root resistant : protection screed required System includes supply , application and termination of coating all complete as per the manufacturer`s methodology.Clean the RCC slab/screed surface and wall for treatment by removing dust, dirt and layers of concrete over the surface. etc. by mechanical tools and wire brushing. Pressure grouting at construction joints or honeycombs with non shrink cementations grout by mixing shrinkage compensating admixture per bag of cement as per manufacturer`s recommendations. Prepare a side gola of 50X50 mm at the junction using polymer modified mortar. Providing and applying liquid applied single component pitch free polyurethane coating in 2 coats at coverage rate of 2kg/sqm to a achieve a minimum DFT of 1.3 mm. (Fibre cloth/fleece/reinforcement should not be used in between two coats of PU as it has adverse effect on elongation property and also affects bonding with slab). Termination shall be done 300 mm above FFl by providing a groove cut of 30mm x 30mm and seal it with shrinkage compensated polymer modified mortar.Lay a 150 GSM geotextile layer to protect the coating from external damage on final coating before laying of screed concrete/final finish. It shall be applied as per manufactures specification. Rates are incl of surface preparation, grouting and chemical application only. (Rates for geotextile, protection plaster and final finishes such as screed or Brick bat filling for slope, china mosaic, tiles etc is not included in above item. It will be added as per EIC requirements).` [Through Rate] |
| 204 | [31.7.1]Providing, mixing and applying SBR polymer (of approved make) modified Cement mortar in proportion of 1:4 (1 cement: 4 graded coarse sand with polymer minimum 2% by wt. of cement used) as per specifications and directions of Engineer-in-charge. 1. 12 mm average thickness. [Through Rate] |
| 205 | [32.44.1]Providing and fixing in position wall panelling at all heights with integral densified calcium silicate panels/tiles of size 595 x 595mm, having NRC (Noise Reduction coefficient) of 0.50 (minimum) as per IS 8225:1987, Light reflectance of 85% (minimum). Non combustible as per BS:476 (part-4), fire performance as per BS:476 (part 6 and7), humidity resistance of 100%, thermal conductivity (0.043 W/m K as per ASTM 518:1991, comprising of a frame made from especially fabricated galvanised mild steel sheet 0.50 mm thick pressed section (galvanizing @120 grams per sqm including both sides) i.e. vertical studs of size 48 x 34 x 36 mm are placed at 600mm centre to centre in a floor and ceiling channel section of size 50 x 32m fixed to the floor and soffit at 600mm centres using 12mm dia,50mm long wedge type expanded zinc alloy dash fastener with 10mm bolt. This same channel is then to be fixed in horizontal direction at 600mm centre to centre so as to form a grid of 600mm x 600mm. Glass wool of 50mm thickness is then to be inserted in the slots and finally calcium silicate non combustible panels/tiles are to be screw fixed with self tapping pan head nickel coated mild steel screws of size 13 x 3.2mm on to this grid leaving an even groove of 1 mm between the panels. The joints between the panels are to be duly jointed and finished using recommended jointing calcium silicate based compound and fibre joint tape roll 50mm wide (90 metre )roll and two coats of primer suitable for panelling as per manufacturer`s specification as per direction of Engineer-in-Charge all complete. 1. With 15 mm thick fully perforated square/butt edge light weight calcium silicate panels/ tiles [Through Rate] |
| 206 | [32.70.2]Supply Installation testing commissioning of Solar Photovoltaic grid connected roof top Plant conforming to MNRE specifications as amended, consisting of Mono/Poly Crystalline silicon solar cells, net metering facility, necessary protections, earthing, mounted on Aluminium/GI structure of suitable strength with following components complete as required:- (a) Solar Photovoltaic Module manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730-Part-1, IS/IEC 61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 16.5%. PV modules used in solar power plants/ systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. (b) Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 400 V AC, three phase, 4 wire, 50Hz plus /- 2.5 Hz, output voltage suitable to generate AC (c) Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degrees C. The PCU shall adjust the voltage and frequency level to suit grid frequency (d) Data Monitoring System complete with accessories. (e) Fixing of Array junction box and Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories etc. as required. (f) Lightning and surge voltage protection. (g) Connections and Interconnections by supplying and fixing required size XLPE insulated copper conductor 1.1 kV grade armoured power and control cables between solar modules, main power cable to grid supply PCU unit along with supplying and fixing of necessary channel/conduit lugs and other accessories etc. as required. 2. Above 10 kWp and up to 100 Kwp [Through Rate] |
| 207 | [4.12.1]Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead up to 50 m and lift up to 1.5 m, as directed by Engineer-in-charge. 1. All kinds of soil [Through Rate] |
| 208 | [4.14.1]Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 1. All kinds of soil. [Through Rate] |
| 209 | [4.16.1.2]Excavating trenches of required width and depth for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m. 1.2. All kind of soil Pipes, cables etc, exceeding 80 mm dia but not exceeding 300 mm dia. [Through Rate] |
| 210 | [4.31.1]Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. 1. All kinds of soil [Through Rate] |
| 211 | [4.32]Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. [Through Rate] |
| 212 | [4.39]Providing and injection chemical emulsion for PRE-CONSTRUCTIONAL ant termite treatment (excluding the cost of chemical emulsion) and creating a chemical barrier under and around the column pits, wall trenches, basement excavation, top surface of plinth filing junction of wall and floor, along with the external perimetre of building, expansion joints surrounding of pipes and conduit etc, complete (plinth area of the building at ground floor only shall be measured) using Chlorpyriphos/ Lindane emulsifiable concentrate of 20% [Through Rate] |
| 213 | [5.23.1]Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. 1. Nominal concrete 1:1.5:3 or richer mix (i/c equivalent design mix) [Through Rate] |
| 214 | [6.1.6]Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: 6. 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) [Through Rate] |
| 215 | [6.14.1]Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1. 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size) [Through Rate] |
| 216 | [6.15.1]Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor four level, excluding cost of centering, shuttering, finishing and reinforcement : 1. 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size) [Through Rate] |
| 217 | [6.16]Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor four level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). [Through Rate] |
| 218 | [6.22.2.3]Providing and laying in position ready mixed plain cement concrete, with cement content as per approved design mix and manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for plain cement concrete work, including pumping of R.M.C. from transit mixer to site of laying and curing, excluding the cost of centering, shuttering and finishing, including cost of curing, admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in-charge. 2.3. All works up to Plinth Level : M-10 grade plain cement concrete (cement content considered @ 220 kg/cum) [Through Rate] |
| 219 | [6.23.2.2]Providing and laying in position ready mixed plain cement concrete, using fly ash and cement content as per approved design mix and manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for plain cement concrete work, including pumping of R.M.C. from transit mixer to site of laying and curing, excluding the cost of centering, shuttering and finishing, including cost of curing, admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in-charge. 2.2. All works up to plinth level M-10 grade plain cement concrete (cement content considered @ 220 kg/cum) [Through Rate] |
| 220 | [6.30.1]Centering and shuttering including strutting, propping etc. and removal of form for 1. Foundations, footings, bases of columns, etc. for mass concrete [Through Rate] |
| 221 | [6.30.2]Centering and shuttering including strutting, propping etc. and removal of form for 2. Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc. [Through Rate] |
| 222 | [6.30.3]Centering and shuttering including strutting, propping etc. and removal of form for 3. Suspended floors, roofs, landings, balconies and access platform [Through Rate] |
| 223 | [6.30.4]Centering and shuttering including strutting, propping etc. and removal of form for 4. Shelves (Cast in situ) [Through Rate] |
| 224 | [6.30.5]Centering and shuttering including strutting, propping etc. and removal of form for 5. Lintels, beams, plinth beams, girders, bressumers and cantilevers [Through Rate] |
| 225 | [6.30.6]Centering and shuttering including strutting, propping etc. and removal of form for 6. Columns, Pillars, Piers, Abutments, Posts and Struts [Through Rate] |
| 226 | [6.30.7]Centering and shuttering including strutting, propping etc. and removal of form for 7. Stairs, (excluding landings) except spiral-staircases [Through Rate] |
| 227 | [6.34.6]Steel reinforcement for R.C.C. work, where not included in the complete rate of RCC, including straightening, cutting, bending, placing in position, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. complete in all respect above plinth level Note:- Reinforcement shall be measured in length including hooks, if any, separately for different diameters as actually used in work , excluding overlaps. Wastage, overlaps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods of binding & placing shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement. 6. Thermo-Mechanically Treated bars of grade Fe-500D or more. [Through Rate] |
| 228 | [6.8.2]Providing and laying damp-proof course with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III): 4 graded stone aggregate 12.5mm nominal size) 2. 40mm thick [Through Rate] |
| 229 | [7.20.2]Brick work with common burnt clay modular bricks of class designation 10.5 in foundation and plinth in: 2. Cement Mortar 1:6 (1 cement : 6 coarse sand) [Through Rate] |
| 230 | [7.21.1]Brick work with common burnt clay non-modular bricks of class designation 10.5 in foundation and plinth in: 1. Cement mortar 1:4 (1 cement : 4 coarse sand) [Through Rate] |
| 231 | [7.50]Providing and laying autoclaved aerated cement blocks masonry with 100 mm thick AAC blocks in super structure above plinth level up to floor IV level in cement mortar 1:4 (1 cement : 4 coarse sand ). The rate includes providing and placing in position 2 Nos. 6 mm dia M.S. bars at every third course of masonry work. [Through Rate] |
| 232 | [7.51]Providing and laying autoclaved aerated cement blocks masonry with 150mm/230mm/300 mm thick AAC blocks in super structure above plinth level up to floor IV level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for separately). [Through Rate] |
| 233 | [7.58]Dressed or moulded one brick cornice laid in cement sand mortar 1:4 including 12 mm thick cement plaster 1:4 or pointing, as required. [Through Rate] |
| 234 | [8.26.2.2]Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. 2.2. Granite of any colour and shade Area of slab over 0.50 sqm [Through Rate] |
| 235 | [8.28]Extra for providing opening of required size and shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. [Through Rate] |
| 236 | [8.30.2]Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth. 2. Granite Stone of approved shade [Through Rate] |
| 237 | [9.17.1]Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : 1. In 75x75 mm deep chase [Through Rate] |
| 238 | [9.18]Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. [Through Rate] |
| 239 | [9.47.3]Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main `T` runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm centre to centre and cross `T` of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main `T` at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross `T` of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main `T` runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm centre to centre along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. 3. 12.5 mm thick square edge PVC Laminated Gypsum Tile of size 595x595 mm, made of Gypsum plasterboard, manufactured from natural gypsum as per IS 2095 part I and laminated with white 0.16mm thick fire retardant PVC film on the face side and 12micron metalized polyester on the back side with all edges sealed with the face side PVC film which goes around and wraps the edges and is bonded to the edges and the back side metalized polyester film so as to make the tile a completely sealed unit. [Through Rate] |
| 240 | [9.57.3]Providing and fixing on wall face Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 3. 150 mm diameter [Through Rate] |
| 241 | [9.59.3]Providing and fixing Unplasticised -PVC pipe clips of approved design to Unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 3. 150 mm [Through Rate] |
| 242 | NS ITEMS- Providing and fixing in position openable S.S Jali of Heavy quality, 100mm dia of standard make approved by engineer in-charge complete in all respect. |
| 243 | providing and fixing PU polish on veneer flush door complete in all respect. |
| 244 | Providing and fixing in position EWC CP jet spray with braided hose and connections complete in all respect. |
| 245 | S/E of Powder Coted Finished galvanized steel Flush Fire doors single leaf in wooden finish of 1hrs Fire rating and tested in accordance with IS 3614 Part II, and BS 476 Part 20 to 22: FRAME : - Door frames to be double rebate profile of 100 x 57 mm manufactured from 1.2 mm thick galvanized steel, profile to have bending radius of 1.4 mm supplied in assembled form ready to install at site. SHUTTER : - Door Shutter in 46 mm thick manufactured from two Nos 0.80 mm thick galvanized steel sheets lock seam jointed at stile edges to form a double skin fully flush shell. Infill of properitory insulation material to be provided for structural rigidity and additional reinforcements and sound Insulation complete with SS Ball bearing Hinges, Mortise dead lock, SS D-type Handles 300 x 22 mm long, Fire rated Door closer, 6mm thick fire rated wired vision panel of size 200 x 300 mm, Dash fastener with PVC cap i/c installation charges complete in all recpect with all labour and petty material required to complete the job in all respect upto entire satisfaction of Engineer-In-Charge (MAKE: ASES (Agni Suraksha)/Om Shakti/Kindle/ Bhawani Fire Protection, Navair) |
| 246 | S/E of NVR-Video Input:20-CH or better, Max Resolution:8MP,Two-way Audio Input:1-ch, 3.5mm,Bandwidth:Income 120Mbps: Outgoing 100Mbps,HDMI/VGA Output:HDMI 2-ch,Audio Output:1x3.5mm, 1xBNC, Decoding Format:IH plus 265/H.265/H.264, Records Encryption:Yes, SATA: 2 SATA interfaces for 2 HDDs, Capacity:Up to 10TB for each HDD, Network Interface: 1xRJ45 self-adaptive 10/100/1000 Mbps network interface, System Compatibility: ONVIF (PROFILE S/T), Consumption: =20W (without HDD) complete in all respect including making necessaryconnections and other petty material etc. |
| 247 | S/E of co-axial TV cable (RG-6) with electrolytic grade solid bare copper conductor, gas injected physical foamed polythylene insulation, screened with laminated aluminium tape and aluminium alloy wire braided, jelly flooded and UV grade PVC jacketed in existing pipe, complete in all respect including making necessary connections and labour etc |
| 248 | S/E of 9U Rack-Lockable Toughened Glass Door, Frame:Steel complete in all respect with all labour and petty material required |
| 249 | S/E of Moulded HDMI cable with Connector complete in all respect with all labour and petty material required |
| 250 | Supply and erection of 55` LED Commercial TV (Pansonic - Make andModel -m LH-55-RM1DX or equivalent model of Samsung/ Sonycomplete in all respect including making necessary connections etc. (Make:Panasonic/Samsung/Sony) |
| 251 | SITC of single headed hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Stainless Steel cap and chain. |
| 252 | SITC of 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required : Gun Metal |
| 253 | SITC of of Two way fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required |
| 254 | SITC of of pressure switch in M.S. pipe line including connection etc. as required. |
| 255 | Supply and Erection of hose box of size 750mmx600mmx250 mm) suitable for 2 No. hose pipe 15 meter, 1 No. short branch pipe complete in all respect. |
| 256 | Providing and fixing fire extinguisher ISI marked complete in all respects.b) ABC Type 4 kg Capacity (multipurpose) ISI Marked (IS 15683) |
| 257 | Providing and fixing fire extinguisher ISI marked complete in all respects.a) CO2 Type 4.5 kg ISI marked.(IS.15683) |
| 258 | S/I/T/C of refrigerant piping made of good quality copper tube with insulation and covering pipe and 4 Core 2.5 Sqmm Copper wire required dia 1.5/2.0 TR cap Split /Cassette / Tower Air Conditioner on wall/Ceiling Complete with all labour and petty material required to complete the job. |
| 259 | S/E of Pvc drain pipe of 25mm dia 1.5/2.0 TR cap Split /Cassette / Tower Air Conditioner on wall/Ceiling Complete with all labour and petty material required to complete the job. |
| 260 | S/E of 2250/2350 VA Invertor sinwave type with Digital Display ( Luminious / Microtek / Sukem) suitable for operation on single phase 230 volts, 50 HZ, AC supply with 2 nos 150 AH Exide batteries having guarantee of 36 Months i/c cost of trolly for batteries complete with all labour and petty material required i/c making necessary connections upto entire staisfaction of Engineer-in-Charge of the work. |
| 261 | Providing and Fixing Electric Control panel for terrace Fire Pump Made out 16 SWG CRCA Sheet Single Door ,Powder coated Red Color out side body , Incorporating automatic switch inbuilt with MNX 25 Contractor , Relay , 4 pole MCB 63amp , Indications showing the power supply condition AMP meter and Volt Meter with Selector Switch auto manual and off Selector Switch , Manual On and Off Push Button , locking arrangement . |
| 262 | Supplying, installation, testing and commissioning of electric driven terrace pump of 450 LPM size at 35 M Head suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump) (a) Horizontal type, multistage, centrifugal, split casing pump of cast iron body and bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520 b) Suitable HP squirrel cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horizontal foot mounted type with Class-`F` insulation, conforming to IS-325. (c) M. S. fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required. (d) Suitable cement concrete foundation duly plastered and with anti vibration pads. |
| 263 | SITC of first-aid Hose Reel 30 mtr long with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve and nozzle. Drum and brackets for fixing the equipment’s on wall. Connections from riser with 25 mm dia stop gun metal valve and M.S. Pipe and socket. |
| 264 | S/E of 40 W decorative post top for 360 indirect light is a weather proof indirect lighting solution which improves horizontal uniformly with reduced glare and improved lighting control. (Havells Make Model-RUBYPT40WLED757PSYMTOPC) or equivalent model of approved brand. |
| 265 | S/I/T/C of High wall 1.5 TR capacity invertor type of 5 Star rating Split Air- conditioning unit rated at 220 volts ( plus ) (-) 10%,single phase, 50 cycle per second electric supply and consisting of condensing and indoor unit,control panel of the unit, LCD Cordless remote, internal control wiring, thermostats, all accessories , , MS stand and 4 KVA up to 130 volts wall mount voltage stablizer and first charge of Gas and without copper refrigerant Copper wire and drain pipe. The work should be completed in all respect including making repair of wall, floor and roof in original shape caused by making holes and chases etc. |
| 266 | SITC of of pressure guage in M.S. pipe line including connection etc. as required. |
| 267 | S/E of 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required : Gun metal |
| 268 | Supplying, installation, testing and commissioning of Smoke detector built with LED complete with mounting base complete as required. |
| 269 | Supplying, installation, testing and commissioning of ABS type manual call pointcomplete as required |
| 270 | Supplying, installation, testing and commissioning of ABS type horn cum strobecomplete as required |
| 271 | Supplying and laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated withannealed copper conductor having XLPE insulation, steel wire armouring and FRLS outer sheath complete as required. |
| 272 | Providing and fixing in position Soap Dish category no 1177 Jaquare Make |
| 273 | Supply and Erection of 1.5 mm sqmm x 3 core PVC insulated multi core copper conductor flexible cable (unarmoured) of 1100 volts grade (round) in existing pole/ pipe, complete in all respect including making necessary connections |
| 274 | Supply and erection of 1.0 mtr 48mm dia G.I pipe bracket with SS Top ball for fixing on the existing HOT DIP Galvanised octagonal pole complete with all labour and material required to complete the job in all respect upto the entire setisfection Engineer in charge of the work. Double Arm /[3Q] |
| 275 | Supply and erection of 1.0 mtr 48mm dia G.I pipe bracket with SS Top ball for fixing on the existing HOT DIP Galvanised octagonal pole complete with all labour and material required to complete the job in all respect upto the entire satisfaction Engineer in charge of the work.(i) Single Arm. /[3Q] |
| 276 | S/E of Air Release Valve 25 mm of in M.S. pipe line including connection with all petty material and labour reqd. |
| 277 | Supply and Erection of Commercial Mineral RO system of 50 Ltr/ hr. water Purification Capacity i/c fixing on wall with all petty material and labour reqd. operation on single phase AC supply complete in all respect upto the entire satisfaction of Engineer- in -charge of the work including making necessary connections etc |
| 278 | S/E of Flood Light 100 watt LED luminaire Outdoor Commercial LED Luminaires made in pressure die cast and heat shrink aluminium extrusion with high power LEDs, Minnimum working hours 50,000 Hours, Minimum output 110 lumens/watt , THD (10% IP-66, Surge Protection and making neccessary connection etc, suitable for operation on 230 volts A.C supply, complete in all respect up to entire satisfaction of the Engineer-in-Charge of the work. |
| 279 | S/E of Street Light 70 watt LED Outdoor Commercial LED luminaire made in pressure die cast and heat shrink aluminium extrusion with high power LEDs, Minnimum working hours 50,000 Hours, Minimum output 110 lumens/watt , THD (10% IP-66, Surge Protection and making neccessary connection etc, suitable for operation on 230 volts A.C supply, complete in all respect up to entire satisfaction of the Engineer-in-Charge of the work. |
| 280 | Supply and erection of 36W 2`x2` Panel Indoor Commercial LED surface/ Recessed mounting, energy efficient LED 6000 K round luminaire, with High Efficacy LEDs, Minimum working hours 35,000 Hours, Minimum output 110 lumens/watt , THD (10% and making necessary connection etc, suitable for operation on 230 volts A.C supply, complete in all respect up to entire satisfaction of the Engineer-in-Charge of the work. |
| 281 | Supply and erection of LED 12 W Indoor Commercial Square/Round Fitting surface/ Recessed mounting, energy efficient LED 6000 K round luminaire, with high power LEDs, Minnimum working hours 35,000 Hours, Minimum output 110 lumens/watt , THD (10% and making neccessary connection etc, suitable for operation on 230 volts A.C supply, complete in all respect up to entire satisfaction of the Engineer-in-Charge of the work. |
| 282 | Supply and erection of LED Batten fitting 1x 20 watt, (4 feet long) Indoor Commercial surface mounting , with high power LEDs, Minimum working hours 50,000 Hours, Minimum output 110 lumens/watt , THD (10%, Extruded Aluminium housing and Square shaped diffuser with wide range of wattage and making necessary connection etc, suitable for operation on 230 volts A.C supply, complete in all respect up to entire satisfaction of the Engineer-in-Charge of the work. |
| 283 | Supply and erection of LED Batten fitting 1x 10 watt, (2 feet long), Indoor Commercial surface mounting with high power LEDs, Minimum working hours 35,000 Hours, Minimum output 110 lumens/watt , Extruded Aluminium housing and Square shaped diffuser with wide range of wattage and making necessary connection etc, suitable for operation on 230 volts A.C supply, complete in all respect up to entire satisfaction of the Engineer-in-Charge of the work. |
| 284 | Supply, and Erection of LED 10W LED Bulkhead light with high power LEDs, Indoor/Outdoor Commercial Minimum working hours 50,000 Hours, Minimum output 110 lumens/watt , THD (10% and making necessary connection etc, suitable for operation on 230 volts A.C supply, complete in all respect up to entire satisfaction of the Engineer-in-Charge of the work. |
| 285 | S/E of ventilation fans (Exhaust fan) Size 300 mm, 900 rpm Heavy Duty ISI marked propeller type suitable for single phase A.C. 230 Volts, 50 HZ supply, A.C capacitor run confirming to IS:23/2/67 , complete with mounting ring with four no.s fixing holes without regulator as per rate contract specifications.with all labour and petty material required |
| 286 | S/E of Fresh air fans (Exhaust fan) 250 mm sweep PVC body with louver shutter, suitable for single phaseA.C. 230 Volts, 50 HZ supply complete with all labour and petty material required to complete the job. |
| 287 | S/E of Fresh air fans (Exhaust fan) 200 mm sweep PVC body with louver shutter, suitable for single phaseA.C. 230 Volts, 50 HZ supply complete with all labour and petty material required to complete the job. |
| 288 | P/F Zinc Coated Clamp 110 mm/160 mm dia i/c cost of 12 mm Screwed GI Rod and fastener and labour for the drilling and fixing fastener in RCC roof etc. complete in all respect to entire satisfaction of Engineer in Charge NS |
| 289 | Supply and erection of 18 W LED Indoor Commercial Square/Round Fitting surface/ Recessed mounting, energy efficient LED 6000 K round luminaire, with high power LEDs, Minimum working hours 35,000 Hours, Minimum output 110 lumens/watt , THD (10% and making necessary connection etc, suitable for operation on 230 volts A.C supply, complete in all respect up to entire satisfaction of the Engineer-in-Charge of the work. |
| 290 | S/E of fire buckets of 9 liters capacity made out of 24 gauge GI sheet and duly painted with one coat of red oxide and two coat of approved paint in red colour written with fire as per fire protection complete with necessary sand filling in the bucket and labour etc. |
| 291 | Earth filling with the earth brought from outside the campus irrespective of 5km lead, including Loading, Unloading, transporting and laying in 20cm in layers, watering and consolidating complete in all respect and fully satisfaction of Engineer-in-charge. NS CP 0% |
| 292 | Supply and Erection of water cooler stainless steel body with 150 ltr /hr and 150 ltr storage capacity (FSS 304) operation on single phase AC supply complete in all respect up-to the entire satisfaction of Engineer- in -charge of the work including making necessary connections etc. |
| 293 | Supply installation, testing and commissioning of EPBAX machine configured for 4 PandT Line and 16 extensions for intercom System (Make- Copper Connection and Model- 416) complete with other petty material required. |
| 294 | S/I/T/C of Cassette 2.0 TR capacity type of 5 Star rating Split Air- conditioning unit rated at 220 volts ( plus ) (-) 10%,single phase, 50 cycle per second electric supply and consisting of condensing and indoor unit,control panel of the unit, LCD Cordless remote, internal control wiring, thermostats, all accessories , , MS stand and Stabilizer 5 KVA 3 step copper up to 130 volts wall mount voltage stablizer and first charge of Gas and without copper refrigerant Copper wire and drain pipe. The work should be completed in all respect including making repair of wall, floor and roof in original shape caused by making holes and chases etc. |
| 295 | Providing and fixing in position Health Faucet (hand shower) chrome finish with 8 mm diametre , one metre long flexible tube and wall hook category no 573 Jaquare Make complete as per satisfaction of engineer in charge NS |
| 296 | S/I/T/C of wall / free standing floor mounting dust and vermin proof compartmentalized cubical panel made out of 2 mm thick CRCA sheet double door,dust and vermin proof with partitions i/c powdered coated paint of approved shade,bonding to earth, with aluminium bus bar of suitable size for operation on 3 phase 4 wire, 415 volts, 50 HZ AC supply, complete in all respect as per given details : 1. Incomer FP MCCB- 200 Amps, 25 KA rating with rotary handle - 01 No. 2. Four Pole ON-Load Change Over Switch 100 Amps-01 No, 3. Out goings FP MCCB 100 A, 25KA rating - 03 Nos. and FP MCCB 63 A, 25KA rating - 03 Nos , 4. Digital VAF meter with built in selector switch and matching CT`s and 1 Set of RYB phase indicating lamps (LED) including control wiring . i/c all labour and petty material to complete the job up to entire satisfaction of E-I-C of work. |
| 297 | Supplying, installation, testing and commissioning of micro processor based intelligent addressable Four loop main fire alarm panel, central processing unit with the following loop modules and capable of supporting not less than 240 devices (including detectors) and minimum 120 detectors per loop and loop length up to 2 km, network communication card, minimum 320 character graphics/LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM), power supply unit (230 ± 5% V, 50 hz), 48 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall have facility to connect printer to printout log and facility to have seamless integration with analog/digital voice evacuation system (which is part of the schedule of work under SH: PA System) and shall be complete with all accessories . The panel shall be compatible for IBMS system with open protocol BACnet/ Modbus over IP complete as per specifications and complete the job in all respect upto the entire satisfaction of the Engineer-in-charge of work. ( Make-Honeywell Model- 14-001-241 DXc4 Four loop Fire Alarm Control Panel or equilent of approved make) |
| 298 | Supply and Fixing of 10kva ups, rated capacity 8000 watts, input voltage range (load (50%) 118 ~ 295 v (± 5 v), output voltage range 208 / 220 / 230 / 240 v ac,dc voltage, (EXIDE SMF batteries 12V x 12Nos 65Ah with Rack of MS Stand and Link Cables) 1Hrs Full Load Backup complete the job in all respect upto the entire satisfaction of the Engineer-in-charge of work. ( Make-Microtek/ Eaton/APC or equivalent of approved make) |
| 299 | SE of HDMI Cable cable 4k supportable Approved Make:Linetek / Kramer / Aten complete in all respect up to the entire satisfaction of the Engineer- in - Charge of the work. |
| 300 | SITC of 8 port POE network switch for audio system Approved Make: Netgear / Dlink / Cisco complete in all respect up to the entire satisfaction of the Engineer- in - Charge of the work. |
| 301 | Supply, erection, testing and commissioning of 13 passengers (G plus 1) Electrical Traction Elevator Room less, Gearless with Full Vision Glass door in each door and serving 2 Stops and 2 Opening with speed of 1.0mtr/Second to be erected in accordance with latest IS Specification of Elevator Act and as per the following Technical Specification. (i) Make of Lift: - OTIS / KONE / MITSUBISHI /SCHINDLER/ORBIS ii) Type and capacity: 13 Passenger Elevator of App. 884 Kg. iii) Speed mps: 1.0 mtr per second iv) Travelling (max) in mtrs: Approx. 4 mtrs v) Serving: 2 stops, 2 opening (all opening on same side) vi) Power Supply: 3 phase, 415 V, 50 HZ A C supply. vii) Control: simplex full collective control with or without attendant. ix) Motor: Permanent Magnet Synchronous Electric Traction Gearless Motor to be hoisted on guide rail within the elevator hoist way x) Location of Motor: Motor to be hoisted above the rail within the elevator hoist way. xi) Type of Drive: A. C. Variable Voltage Variable frequency with 16 Bit Microprocessor xii) Car Size: min. 1600 mm wide x 1400 mm depth or as per manufacturer design. xiii) Hoist way available: Appx.2500 mm x 1900 mm xiv) Clear Opening of door: 900 mm wide x 2000 mm high xv) Car Enclosure and Panel: Aesthetic Stainless Steel scratch Resistance honey comb finish cabin and Panel. xvi) Car door: Stainless Steel scratch Resistance honey comb finish with Full Vision Glass door xvii) Door Frame: Stainless Steel scratch Resistance honey comb finish with Full Vision Glass door xviii) False Ceiling: Stainless steel decorative false ceiling with LED Lighting and blower fan xix) Flooring: - 1, 2 (Granite Flooring) xx) Door Operation: Automatic DC/AC with adjustable Door Opening and closing timings with center opening sliding door Other Features: i) Battery operated intercom, emergency alarm and emergency light with maintained free rechargeable battery. ii) Adjustable guide shoes. (Ensures good ride comfort) iii) Digital direction and position indicator in Car and at all landings. iv) Integral full height car opening panel with luminous combined with direction arrows, overload warning indicator and services cabinet. v) Hands free press and speak intercom with EPABX for three way communication. vi) Automatic rescue device with Manual rescue Lever (to rescue the Passenger in case of emergency) the device will bring the elevators to the nearest floor and open the door automatically in Case of power / phase failure / low voltage. vii) Full height infrared safety curtain (Highly sensitive safety device for safe entrance and exit of the Passenger into the Car and automatic floor announcer. viii) Diffused lighting in car. ix) Cross flow fans=2 Nos. x) Looking mirror in side of lift car. xi) Face plate Finish: stainless steel scratch Resistance. xii) Face plate: Rectangular. xiii) A three feet high railing shall be provided on car top xiv) The motor shall be high starting torque and low starting current and shall be arranged for self-lubrication. xv) Proper weight screen shall be provided at the hoist way. xvi) Fire retardant compound coated traveling cable shall be used. xvii) Micro Movements L.E.D. based Buttons. xviii) Load Weighing device with overload bypass feature. (Audio Visual over load indicator in the car) xix) Steel items such as Door Frames Sill Angles, Fascia Plates, and Spring Buffers. xx) Braille fixtures, Lift announcement system, Pit ladder, Hand rail, Pressure sensing device and Additional Car Gate Lock. xxi) Three Side Hand Rails in Stainless Steel Finish xxii) System Capable of withstanding plus 10% to –10% Variation in Supply Voltage Fluctuations. (C.V.T should be provided for Protection of lift against Single phase, Low voltage and over voltage) xxiii) Car Platform constructed out of Cold Rolled Grain Oriented Formed Sheets of Steel xxiv) The whole machinery shall be mounted on appropriate anti vibration supports to minimize voice and vibration. xxv) A handrail not less than 0.60mtr long and 1.0 mtr. Above floor level shall be fixed adjacent to the control panel. xxvi) The time of automatically closing door shall be minimum 5 seconds and the closing speed shall not exceed 0.25mtr./ Seconds xxvii) Over speed governor (Electro-mechanical device that prevents free fall in case the lift is travelling at speed more than 10% of the rated speed in downward direction. xxvii) All other required features relates the operation of lift by the Handicaps and Blind person as per instruction of lift inspector. Note:-Elevator Inspection and License and Insurance fees will be paid by agency. |
| 302 | Providing, installation, testing and commissioning of Single Sided digital display Exit Sign Board for wall / ceiling / pendant cantilever mounting, with white housing, Red Stencil and Battery backup capability and dual power supply (AC/DC) and push to test switch for mandated code compliance testing, including long life SMF rechargeable Ni Cd battery and internal solid-state transfer switch automatically connects the internal battery to LED board for minimum 90 minute emergency illumination. Fully automatic solid-state, two-rate charger initiates battery charging to recharge a discharged battery in 24 hours. complete in all respect. |
| 303 | Supply , Installation, testing and commissioning of 40 KVA water cooled , silent diesel Generating set as per CPCB IV norms or as latest amendments CPCB, complete with alternator rated at three phase 415 volts, 50 cycle, 0.8 PF and 1500 RPM with AMF Panel (outside the canopy),Acoustic Enclosure and battery charger etc.( To be installed on existing platform excluding cost of platform ) as per following specifications : - `A. DIESEL ENGINE : Engine multi cylinder, developing output as per 40 KVA DG Set at 1500 RPM, (as per CPCB IV norms or as latest amendments CPCB), totally enclosed,water cooled, comprising compression ignition, electric start, 4 stroke high speed diesel engine conforming to IS - 4722 , ISO- 3046, BS - 5514. The engine shall be complete with all standard and electrical accessories as per standard supply of manufactures. The engine shall be coupled with 3 phase 415 volts, 50 cycle, 0.8 PF and 1500 RPM, alternator as per IS -4722 / BIS - 2613, rated for 24 hours of continuous operation with 10 % over load capacity for one hour in every 12 hours and comprising with AMF Panel of required size inside/outside of canopy with all accessories as required, as per IS /IEC :60947(Part-I) / 2007 b) ON / OFF start keys c) Lube oil pressure gauge d) Fuel Tank with capacity for 8 hours continuous running at full load e) Residential Silencer of required size and length i/c all necessary material as required.` `f) 1 No, 12 Volt Battery of required capacity, DC Mtc. Free battery with leads and container. g) AVM Pads fitted on base frame h) The base frame would be fabricated from suitable M.S.Channel/section machined to perfect alignment of the engine and alternator with rigid construction and necessary reinforcement to ensure minimum vibration. (i) AC Digital volts and Amperes meters with selector switch of class 1.5 accuracy (j) 3 Nos , 4 pole MCCB of suitable capacity on mains supply input and output of DG set and 2 Nos 4 Pole contactors of suitable capacity for mains and DG (n) 5 nos. Indicating lamps to indicate main low voltage , load on mains , DG set running , load on set and battery charger ON (o) Under voltage relay for mains (p) Over voltage protection (q) Any other accessories to make the generating set functional shall be installed as per manufacturer`s specification. ` `(B) BATTERY CHARGER: The battery charger with volt meter and Ammeter shall be installed of required size and rating for charging of battery from mains. This will be in addition to the battery charging alternator fitted on the engine. (C) ACOUSTIC ENCLOSURE : Acoustic enclosure shall be provided as per Technical specification as follows :- 1) CONSTRUCTION and PAINTING : i) The enclosure shall be fabricated out of 16 SWG CRCA sheet silent D.G. set container shall be of modular construction with the provision to assemble and dismantle easily at site of work. ii) The base frame shall be made of load bearing suitable section/channel. iii) Durable industrial system is to be provided on the doors and doors are fitted with high quality EPDM gasket to avoid leakage of sound. iv) Weather proof anti corrosion treatment to be provided to the entire structure with powder coating. v) Neutral/Body earthing points at the side of enclosure are to be provided vi) Emergency stop push button shall be provided outside the container. vii) A tube fitting with tube rod for proper light inside the canopy shall be provided. ` `(D) ACOUSTIC INSULATION : i) Sound proofing of the enclosure shall be done with quality rock wood/Mineral wood/PU foam conforming to IS-8183-1993 of 25mm thickness and density at 30 Kg./M compressed along with 3mm thick vinyl sheet and non ferrous sheet. ii) Exhaust pipe is to be thoroughly insulated by covering it with glass wool and further clade with Aluminium sheet. iii) Noise level as per Central Pollution Control Board (CBCB)with latest amendments. Note Any other material required to complete the Acoustic Enclosure shall be installed as per manufacturer`s specifications Note -CEI License fees and 8 hrs running fuel cost for testing at site will be borne by the agency |
| 304 | upply, Installation, Testing and Comissioning of 5MP Dome Camera with 2.8-12mm Motorized Varifocal lens, 1/2.8` SONY - CMOS 5MP Active Pixel, Minimum Illumination - Color - 0.01 Lux @F1.2, Focal Length - 2.8mm - 12mm, Focus Range - 0.3m to infinity, Aperture (F#) - F1.6-F2.8, Iris Type - Motorized Varifocal Iris, IR Range - Up to 50m, IR Led Wavelength - 850nm, IR Switching - Auto/ Manual, Audio IN - 1, Audio OUT - 1, Two-way Audio -Supported, Audio Compression - G.726 and G.711g, Alarm In - 1 (Phoenix type connector), Alarm Out - 1 (Phoenix type connector), SD Card - Up to 512GB, Available Resolutions - 2592 x 1944, 2592 x 1520, 2048 x 1536, 1920 x 1080, `720p, D1, 2CIF, CIF, Max Resolution - 2592 x 1944, Bitrate - 128 kbps-16Mbps, Bitrate Type - CBR, VBR, Video Compression - H.265, H.264, MJPEG, Frame Rate - 1- 30fps, Shutter Speed - 1/15s - 1/100000s, Adaptive Streaming - Yes, ONVIF Profiles - S, G, and T, Edge Recording - Yes, Alarm Recording - Pre and Post, Motion Recording - Yes, Time Triggered - Yes, WDR True -WDR (120dB), SNR - )70dB, Storage - NAS, SD Card, Certifications - NDAA Compliant, BIS, CE, IP67, FCC Part-15 Subpart — B, ONVIF S, G and T,IK10,UL, NEMA 4X**, STQC Certified with OWASP ASVS 4.0L2, SIRA . Make: Matrix/ Bosch/ Norden |
| 305 | Supply, Installation, Testing, Commissioning of 5MP Bullet Camera with 2.8-12mm Motorized Varifocal lens, 1/2.8` SONY - CMOS 5MP Active Pixel, Minimum Illumination - Color - 0.01 Lux @F1.2, Focal Length - 2.8mm — 12mm, Focus Range - 0.3m to infinity, Aperture (F#) - F1.6-F2.8, Iris Type - Motorized Varifocal Iris, IR Range - Up to 50m, IR Led Wavelength - 850nm, IR Switching - Auto/ Manual, Audio IN - 1, Audio OUT - 1, Two-way Audio -Supported, Audio Compression - G.726 and G.711g, Alarm In - 1 (Phoenix type connector), Alarm Out - 1 (Phoenix type connector), SD Card - Up to 512GB, Camera Adjustment Angle - Pan: 0° to 360°, Tilt: 0° to 90° , Rotate: 0° to 360°, Available Resolutions - 2592 x 1944, 2592 x 1520, 2048 x 1536, 1920 x 1080, 720p, D1, 2CIF, CIF, Max Resolution - 2592 x 1944, Bitrate - 128 kbps-16Mbps, Bitrate Type - CBR, VBR, Video Compression - H.265, H.264, MJPEG, Frame Rate - 1-30fps, Shutter Speed - 1/15s -1/100000s, Adaptive Streaming - Yes, ONVIF Profiles - S, G, and T, Edge Recording - Yes, Alarm Recording - Pre and Post, Motion Recording - Yes, Time Triggered - Yes, WDR True - WDR (120dB), SNR - )70dB, Storage - NAS, SD Card, Certifications - NDAA Compliant, BIS, CE, IP67, FCC Part-15 Subpart - B, ONVIF S, G and T,IK10,UL, NEMA 4X**, STQC Certified with OWASP ASVS 4.0L2, SIRA. Make: Matrix/ Bosch/ Norden |
| 306 | Supply, Installation, Testing and Comissioning of Push Button Telephone Desktop model CLI, flash , redial ,mic with speaker complete in all respect. Make :-Beetel /Panasonic/Matrix |
| 307 | Supply, and Erection of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor,, Rated power input 30/32/35 watts ,class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 7.5, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pins, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete with 24 months of warranty as required (Havells-Make, Model-Efficiencia Prime BLDC) or equivalent model of approved brand list |
| 308 | Supply and Erection of oscillating type wall fan of 16` (400mm) sweep Rectangular shape Hi gloss ABS plastic body uniquely designed fan wider blades with square wire guard and high rated speed motor for better air delivery, Remote controlled Functions, Power input : 50- 60 watts complete with fixing on wall with suitable arrangements including making necessary connection from nearest point with cost of cu wire required . ( Havell- Make and Model- Aindrila Premium Dusty Rose White/Silky Cristal/Blue Grey or equivalent model of other approved brands) Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail