| 1 | [10.49.1]Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : 1. Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. [Through Rate] |
| 2 | [10.58]Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. [Through Rate] |
| 3 | [10.63.2]Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. 2. Size of Tile 600x600 mm [Through Rate] |
| 4 | [11.58]Providing and applying two coats white cement based putty of approved brand and manufacturer, over plastered surface and grinding the surface smooth with sand paper to get en even and smooth finish including cost and carriage of all material , labour charges, scaffolding, sundries etc. complete [Through Rate] |
| 5 | [11.64.1]Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : 1. New work (two or more coats) over and including water thinnable priming coat with cement primer [Through Rate] |
| 6 | [12.157.1.2]Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, panelling and dash fasteners to be paid for separately) : 1.2. For fixed portion Powder coated aluminium (minimum thickness of powder coating 50 micron) [Through Rate] |
| 7 | [12.157.2.2]Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, panelling and dash fasteners to be paid for separately) : 2.2. For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Powder coated aluminium (minimum thickness of powder coating 50 micron) [Through Rate] |
| 8 | [12.159.1]Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): 1. With float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm) [Through Rate] |
| 9 | [13.41]Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories and stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). [Through Rate] |
| 10 | [20.71.1]Supply, erection, testing of Ceiling fans IS marked (as per IS code 374) with suitable GI pipe complete in all respects complete as per directions of Engineer-in-charge 1. 48\\" (1200mm) [Through Rate] |
| 11 | [22.104.1]Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : 1. 15 mm nominal bore [Through Rate] |
| 12 | [22.108.1]Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 1. 15mm nominal bore [Through Rate] |
| 13 | [22.2.1]Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:- 1. White vitreous chinaware Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer [Through Rate] |
| 14 | [22.34]Providing and fixing floor mounted, white vitreous chinaware single piece, double traps syphonic water closet of approved brand/make, shape, size and pattern including integrated white vitreous chinaware cistern of capacity 10 litres with dual flushing system, including all fittings and fixtures with seat cover, cistern fittings, nuts, bolts and gasket etc including making connection with the existing P/S trap, complete in all respect as per directions of Engineer-in-Charge. [Through Rate] |
| 15 | [23.22.1.11]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.11. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. 4 pole MCCB 200 to 250 amp, 25 KA [Through Rate] |
| 16 | [23.22.1.9]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.9. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. 4 pole MCCB 6 amp to 100 amp , 25 KA [Through Rate] |
| 17 | [23.22.5.1]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.1. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 6 amp. to 32 amp Single Pole [Through Rate] |
| 18 | [23.22.5.4]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.4. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 40 amp to 63 amp. Double pole [Through Rate] |
| 19 | [23.22.5.8]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.8. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 40 amp to 63 amp. MCBs FOUR POLE [Through Rate] |
| 20 | [23.5.6.1]COPPER WIRING IN EXISTING PVC/MS CONDUIT PIPE SURFACE/RECESSED FOR ELECTRICAL POINTS 6.1. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in existing MS/PVC Conduit etc as required. 1 run of Size 1.50 Sqmm(1/1.40mm) [Through Rate] |
| 21 | [23.5.6.3]COPPER WIRING IN EXISTING PVC/MS CONDUIT PIPE SURFACE/RECESSED FOR ELECTRICAL POINTS 6.3. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in existing MS/PVC Conduit etc as required. 1 run of Size 4 Sqmm(1/2.24mm) [Through Rate] |
| 22 | [23.5.6.4]COPPER WIRING IN EXISTING PVC/MS CONDUIT PIPE SURFACE/RECESSED FOR ELECTRICAL POINTS 6.4. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in existing MS/PVC Conduit etc as required. 1 run of Size 6 Sqmm(1/2.80mm) [Through Rate] |
| 23 | [23.5.6.5]COPPER WIRING IN EXISTING PVC/MS CONDUIT PIPE SURFACE/RECESSED FOR ELECTRICAL POINTS 6.5. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in existing MS/PVC Conduit etc as required. 1 run of Size 10 Sqmm(1/3.50 mm) [Through Rate] |
| 24 | [23.7.6.1]PVC CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS 6.1. Supply and erection of PVC CONDUIT ISI marked (Medium) recessed in wall/ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC pipe of 20 mm dia. [Through Rate] |
| 25 | [23.7.6.2]PVC CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS 6.2. Supply and erection of PVC CONDUIT ISI marked (Medium) recessed in wall/ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC pipe of 25 mm dia. [Through Rate] |
| 26 | [23.8.10.1]FITTING AND ACCESSORIES 10.1. Providing and fixing GI concealed sheet metal boxes with inner and outer face plate including concealing the box in wall and fixing in position with inner plate and face plate with all labour and material required for the job complete in all respects. 1 & 2 Modules including combined plate for Telephone and data [Through Rate] |
| 27 | [23.8.10.2]FITTING AND ACCESSORIES 10.2. Providing and fixing GI concealed sheet metal boxes with inner and outer face plate including concealing the box in wall and fixing in position with inner plate and face plate with all labour and material required for the job complete in all respects. 3 Modules [Through Rate] |
| 28 | [23.8.10.3]FITTING AND ACCESSORIES 10.3. Providing and fixing GI concealed sheet metal boxes with inner and outer face plate including concealing the box in wall and fixing in position with inner plate and face plate with all labour and material required for the job complete in all respects. 4 Modules [Through Rate] |
| 29 | [23.8.10.4]FITTING AND ACCESSORIES 10.4. Providing and fixing GI concealed sheet metal boxes with inner and outer face plate including concealing the box in wall and fixing in position with inner plate and face plate with all labour and material required for the job complete in all respects. 6 Modules [Through Rate] |
| 30 | [23.8.10.5]FITTING AND ACCESSORIES 10.5. Providing and fixing GI concealed sheet metal boxes with inner and outer face plate including concealing the box in wall and fixing in position with inner plate and face plate with all labour and material required for the job complete in all respects. 8 Modules [Through Rate] |
| 31 | [23.8.10.6]FITTING AND ACCESSORIES 10.6. Providing and fixing GI concealed sheet metal boxes with inner and outer face plate including concealing the box in wall and fixing in position with inner plate and face plate with all labour and material required for the job complete in all respects. 12 Modules [Through Rate] |
| 32 | [23.8.11.1]FITTING AND ACCESSORIES 11.1. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. 5 amp 1 way switch [Through Rate] |
| 33 | [23.8.11.10]FITTING AND ACCESSORIES 11.10. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. Blanking plate [Through Rate] |
| 34 | [23.8.11.11]FITTING AND ACCESSORIES 11.11. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. RJ 45 Computer DATA socket outlet for CAT 6 or CAT6e cable Modular type [Through Rate] |
| 35 | [23.8.11.3]FITTING AND ACCESSORIES 11.3. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. 15 amp 1 way switch [Through Rate] |
| 36 | [23.8.11.4]FITTING AND ACCESSORIES 11.4. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. 5 amp Socket [Through Rate] |
| 37 | [23.8.11.5]FITTING AND ACCESSORIES 11.5. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. 15 amp 6 pin Socket [Through Rate] |
| 38 | [23.8.11.7]FITTING AND ACCESSORIES 11.7. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. step type Fan Regulator 2 modules 300 watt [Through Rate] |
| 39 | [23.8.12]FITTING AND ACCESSORIES 12. Supply and Fixing 3 mm thick Bakelite sheet cover on existing MS/PVC junction box/tee etc including fixing with brass screws and washers. [Through Rate] |
| 40 | [24.13.40]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 40. 35 Sq mm 4 core (Arm.) [Through Rate] |
| 41 | [24.13.48]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 48. 50 Sq mm 4 core (Arm.) [Through Rate] |
| 42 | [24.13.56]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 56. 70 Sq mm 4 core (Arm.) [Through Rate] |
| 43 | [32.46.2]Providing and fixing false ceiling at all heights with GRG (Glass Fibre Reinforced Gypsum) false ceiling tiles of Size 595x595 mm of approved texture, design and patterns having moisture content less than 2%, humidity resistance of 99%, NRC0.50 to 0.75 as per IS 8225:1987, Non combustible as per BS 476 (part 4)-1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on inter-locking metal T-Grid of hot dipped galvanised iron section of 0.33mm thick (galvanized @ 120 grams per sqm including both sides) comprising of main-T runners of size 15x32 mm of length 3000 mm, cross - T of size 15x32 mm of length 1200 mm and secondary intermediate cross-T of size 15x32 mm of length 600mm to form grid module of size 600 x 600 mm, suspended from ceiling using galvanised mild steel items (galvanizing @ 80 grams per sqm) i.e. 50 mm long, 8 mm outer diameter M-6 dash fasteners, 6 mm dia fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x2 mm. Galvanised iron perimeter wall angle of size 24x24x0.40 mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450 mm centre to centre and 40 mm long dry wall wood screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in-Charge. 2. With fully perforated 12 mm thick micro tegular edged or 10 mm thick square edged GRG false ceiling tiles. [Through Rate] |
| 44 | S/E of fresh air fans (Exhaust fan) 250mm sweep PVC body with louver shutter, suitable for single phase A.C. 230 Volts, 50 HZ supply complete with all labour and petty material required to complete the job. |
| 45 | S/I/T/C of High wall 1.8 TR capacity invertor type of 3 Star rating Split Air- conditioning unit rated at 220 volts ( plus ) (-) 10%,single phase, 50 cycle per second electric supply and consisting of condensing and indoor unit,control panel of the unit, LCD Cordless remote, internal control wiring, thermostats, all accessories , , MS stand and 5 KVA up to 130 volts wall mount voltage stablizer and first charge of Gas and without copper refrigerant Copper wire and drain pipe. The work should be completed in all respect including making repair of wall, floor and roof in original shape caused by making holes and chases etc. |
| 46 | S/I/T/C of refrigerant piping made of good quality copper tube with insulation and covering pipe and 4 Core 2.5 Sqmm Copper wire required dia 1.5/2.0 TR cap Split /Cassette / Tower Air Conditioner on wall/Ceiling Complete with all labour and petty material required to complete the job. |
| 47 | S/E of Pvc drain pipe of 25mm dia 1.5/2.0 TR cap Split /Cassette / Tower Air Conditioner on wall/Ceiling Complete with all labour and petty material required to complete the job. |
| 48 | Supply, Testing and Commissioning of wall fan 16` sweep (400mm) Oscillating type complete with built-in regulator. The fan is to fixed on wall with suitable fixing arrangement including connection from nearest light point with cost of Cu wire required |
| 49 | Supply and erection of modular type Motor starter 25 amp, 2 module (for AC point) on existing modular box fixing with all petty material and labour reqd. |
| 50 | Supply and Erection of 1.5 mm sqmm x 3 core PVC insulated multi core copper conductor flexible cable (unarmoured) of 1100 volts grade (round) in existing pole/ pipe, complete in all respect including making necessary connections |
| 51 | Supply and erection of Indoor Commercial LED 18 W Square/Round Fitting surface/ Recessed mounting, energy efficient LED 6000 K round luminaire, with high power LEDs, Minnimum working hours 35,000 Hours, Minimum output 110 lumens/watt , THD (10% and making neccessary connection etc, suitable for operation on 230 volts A.C supply, complete in all respect up to entire satisfaction of the Engineer-in-Charge of the work. |
| 52 | S/E of LED Flood Light 200 watt Outdoor Commercial LED lumaire made in pressure die cast and heat shrink aluminium extrusion with high power LEDs, Minimum working hours 50,000 Hours, Minimum output 110 lumens/watt , THD (10% IP-66, Surge Protection and making neccessary connection etc, suitable for operation on 230 volts A.C supply, complete in all respect up to entire satisfaction of the Engineer-in-Charge of the work. |
| 53 | S/E of Flood Light 100 watt LED luminaire Outdoor Commercial LED Luminaires made in pressure die cast and heat shrink aluminium extrusion with high power LEDs, Minnimum working hours 50,000 Hours, Minimum output 110 lumens/watt , THD (10% IP-66, Surge Protection and making neccessary connection etc, suitable for operation on 230 volts A.C supply, complete in all respect up to entire satisfaction of the Engineer-in-Charge of the work. |
| 54 | S/E of Street Light 70 watt LED Outdoor Commercial LED luminaire made in pressure die cast and heat shrink aluminium extrusion with high power LEDs, Minnimum working hours 50,000 Hours, Minimum output 110 lumens/watt , THD (10% IP-66, Surge Protection and making neccessary connection etc, suitable for operation on 230 volts A.C supply, complete in all respect up to entire satisfaction of the Engineer-in-Charge of the work. |
| 55 | Supply and erection of 36W 2`x2` Panel Indoor Commercial LED surface/ Recessed mounting, energy efficient LED 6000 K round luminaire, with High Efficacy LEDs, Minimum working hours 35,000 Hours, Minimum output 110 lumens/watt , THD (10% and making necessary connection etc, suitable for operation on 230 volts A.C supply, complete in all respect up to entire satisfaction of the Engineer-in-Charge of the work. |
| 56 | Supply and erection of LED 12 W Indoor Commercial Square/Round Fitting surface/ Recessed mounting, energy efficient LED 6000 K round luminaire, with high power LEDs, Minnimum working hours 35,000 Hours, Minimum output 110 lumens/watt , THD (10% and making neccessary connection etc, suitable for operation on 230 volts A.C supply, complete in all respect up to entire satisfaction of the Engineer-in-Charge of the work. |
| 57 | Supply and erection of LED Batten fitting 1x 20 watt, (4 feet long) Indoor Commercial surface mounting , with high power LEDs, Minimum working hours 50,000 Hours, Minimum output 110 lumens/watt , THD (10%, Extruded Aluminium housing and Square shaped diffuser with wide range of wattage and making necessary connection etc, suitable for operation on 230 volts A.C supply, complete in all respect up to entire satisfaction of the Engineer-in-Charge of the work. |
| 58 | S/I/T/C of LED par Light as per LED Source : 54PCS of 3W each LEDs of colours (R12 G12 B12 W18), Lens angle : 25º(30º, 45º, 60º optional),Channel mode : 3 / 4 / 6 / 7 / 8 and DMX channel mode 0-100% , linear dimmer Function : color mix, automatic colour change, built-in programme and strobe effect with adjustable speed Sound controlled via built-in microphone Adjustable sound sensitivity LED Display, easy to Control : auto, sound active, DMX512, software Overheating protection as per IP:20 and Power Supply : 100-240V, frequency 50 to 60hz ,Power Consumption: 180W Complete with all labour and material reqd. |
| 59 | S/I/T/C of LED profile spot light as per Power Consumption : 200W , Supply Voltage : 90-250V and frequency-50 to60Hz , Working position : Any safe working position, Lamp : Super high power LEDs: White 180W (Cool white or warm white colour temp. 3200K)• Average lifetime is over 50000hrs • CRI :)90 Lens angle : 19º (26º/36º/50º) optional as reqd. , LED display Channel : 2 CHs and • IP rate: IP20 indoor Special zoom function with manual adjustment • Control made: Master/Slave synchronization, DMX 512 control and automatic run, Construction : Die-casting aluminum housing with 4nos Stainless steel shutter blade assembly of colour Silver white and black (optional) Complete with all labour and material reqd. |
| 60 | S/I/T/C of LED Wall Washer Cyclorama lights as per Light source: 18 Pcs of 12W each 4 in1 high brightness LEDs, Lens angle : 25º (30º, 45º, 60º optional as reqd.) DMX channel : 3 / 4 / 6 / 7 / 9 and DMX channel mode : 0-100% , linear dimmer Function: colour mix, automatic colour change,built-in programme and strobe effect with adjustable speed Sound controlled via built-in microphone Adjustable sound sensitivity • LED Display, easy to control • auto, sound active, DMX512, Software Overheating protection as per IP:20 , • Supply Voltage: 100-220V, frequency : 50 to 60hz , • Power Consumption : 230W Complete with all labour and material reqd. |
| 61 | S/I/T/C of LED Fresnel light 150 watt , Chip on board LED drive current : 5 amp, colour temperature 3200K , input voltages 100 to 240 volts, frequency 50 Hz , power consumption : 160 watt, Four digital channel display, DMX 512 control signal , two DMX channel, 0 to 100% dimmer, optical glass Fresnel lens of 150mm with protection-IP: 20 and barn door leaf including cooling fan construction with CRC sheet metal matt black finish Complete with all labour and material reqd. |
| 62 | S/I/T/C of Moving lights as per Light Source: 19pcs of 15W (RGBW) 4-in1 high brightness LED colour temperature- 8000K and life span-100,000 hours , low power consumption: 300w, • Input Voltage: AC110-240V, frequency-50 to 60Hz • Strobe: 1-25 times/sec, Dimming: 0-100% linear dimming . and Control: DMX 512 / Master-slave/Auto-running.• Display: Wide LCD display screen with Chinese and English and Protection as per IP:20 Rating Complete with all labour and material reqd. |
| 63 | Supply and laying of stage light point wiring made out 1.5 sq mm x 3 core multi stand flexible cable with 25 mm PVC conduit as per required laying between light fixture to MCBs DB. Including16 amp output socket and top on light bar with metal box and required sheet. Complete with all labour and material reqd. |
| 64 | S/E/T/C of Universal DMX controller for 40 units with a maximum of 36 channels each, Constant monitoring of output parameters, using the scroll function, operators can control block of 6 channels at a time., 40 chases -programs - presets-psychos, the section dedicated to automated fixtures(scanners or moving head units) has a dual coordinate system: absolute and relative, This possibilities allows to achieve perfect fixture positioning, pilot 2000 is a standard 190 rack mounting unit of size (482x222x75)mm, SMX in/out connector, SMPTE socket for sync of memory change independent adjustment of crossfade time between presets or scenes, Audio input and built-in microphone in for music sync functions, Midi in/through out sockets, possibility of data and memories on PC, Jack socket for up/down pedal control of memory changes suitable for Supply- 110V- 120V/220V- 230V, frequency- 50 to 60 Hz and Power consumtion-15W Complete with all labour and material reqd. |
| 65 | Supply Erection Testing and Commissioning of 8 Way DMXSplitter, DMX 512 standard 8way DMX distribution with one input and suitable for 3 pin XLR connectors,input voltage 100-240volt. i/c output indicator for each chanel Complete with all labour and material reqd. |
| 66 | Providing and laying of DMX signal cable wiring with 2 core shielded cable and 25 mm PVC conduit including required connector Complete with all labour and material reqd. |
| 67 | Supply and fixing of fixed type light bar made out of 48 OD m/s pipe B-Class round pipe welded with 80 mm x 40 mm x 16 SWG. Tubular pipe for wiring and electrical sockets, both pipes welded by 25 mmx 25 mm tubular pipe in every 2000 mm centre to centre including cutting of sockets and wire entry holes as required as per site conditions. The bar suspended by roof slab with 25 mm x 5 mm MS flat clamp and 40 mm x 40 mm x 3 mm MS angle required suspenders Complete with all labour and material reqd. |
| 68 | P/F of MS Pipe Ladders to be provided on sides of the Stage of Size: 600 x 1200mm made of 50mm x 25mm tubular pipe frame suspended by roof slab with required suspenders as per site requirment complete with all labour and material reqd. Please Enable Macros to View BoQ information |