Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared. HSR 4.1 |
| 2 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead up to 50 m and lift up to 1.5 m, as directed by Engineer-in-charge. 1. All kinds of soil HSR 4.12 |
| 3 | Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. 1. All kinds of soil HSR 4.31 |
| 4 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. HSR 4.32 |
| 5 | Excavating, supplying and filling of local earth (including royalty) by mechanical transport up to a lead of 1 km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. HSR 4.33 |
| 6 | Providing and injection chemical emulsion for PRE-CONSTRUCTIONAL ant termite treatment (excluding the cost of chemical emulsion) and creating a chemical barrier under and around the column pits, wall trenches, basement excavation, top surface of plinth filing junction of wall and floor, along with the external perimetre of building, expansion joints surrounding of pipes and conduit etc, complete (plinth area of the building at ground floor only shall be measured) using Chlorpyriphos/ Lindane emulsifiable concentrate of 20% HSR 4.39 |
| 7 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. HSR 5.70 |
| 8 | Schedule A By Mechanical Transport including loading, unloading and stacking 2. Earth HSR 3.1 |
| 9 | Schedule A By Mechanical Transport including loading, unloading and stacking 2. Earth HSR 3.1 |
| 10 | Schedule A By Mechanical Transport including loading, unloading and stacking 2. Earth HSR 3.1 |
| 11 | B BRICK WORK Providing half brick masonry with common burnt clay non-modular bricks of class designation 10.5 in cement mortar 1:3 (1 Cement : 3 coarse sand) in superstructure for closing cavity 5 to 7.5 cm wide in cavity wall complete with 10cm / 11.4 cm wide bitumen felt type 3 grade 1. HSR 7.25 |
| 12 | E READY MIX CEMENT CONCRETE Providing and laying in position ready mixed plain cement concrete, with cement content as per approved design mix and manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for plain cement concrete work, including pumping of R.M.C. from transit mixer to site of laying and curing, excluding the cost of centering, shuttering and finishing, including cost of curing, admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in-charge. 2.1. All works up to Plinth Level :M-20 grade plain cement concrete. (cement content considered @ 300 kg/cum) HSR 6.22 |
| 13 | E READY MIX CEMENT CONCRETE Providing and laying in position ready mixed plain cement concrete, with cement content as per approved design mix and manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for plain cement concrete work, including pumping of R.M.C. from transit mixer to site of laying and curing, excluding the cost of centering, shuttering and finishing, including cost of curing, admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in-charge. 2.2. All works up to Plinth Level :M-15 grade plain cement concrete. (cement content considered @ 240 kg/cum) HSR 6.22 |
| 14 | E READY MIX CEMENT CONCRETE Providing and laying in position ready mixed plain cement concrete, with cement content as per approved design mix and manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for plain cement concrete work, including pumping of R.M.C. from transit mixer to site of laying and curing, excluding the cost of centering, shuttering and finishing, including cost of curing, admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in-charge. 2.3. All works up to Plinth Level :M-10 grade plain cement concrete (cement content considered @ 220 kg/cum) HSR 6.22 |
| 15 | F READY MIX CEMENT CONCRETE WITH FLYASH Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work, including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in-charge. 1. All works up to plinth level HSR 6.24 |
| 16 | F READY MIX CEMENT CONCRETE WITH FLYASH Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work, including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in-charge. 2. All works above plinth level up to floor IV level HSR 6.24 |
| 17 | G DESIGN MIX CONCRETE Extra for providing richer mixes up to plinth and at all floor levels. 1. Providing M-30 grade concrete instead of M-25 grade BMC/ RMC. (Note:- Cement content considered in M-30 is @ 340 kg/cum) HSR 6.26 |
| 18 | G DESIGN MIX CONCRETE Extra for R.C.C./ B.M.C/ R.M.C. work above floor IV level for each three floors or part thereof. HSR 6.27 |
| 19 | I CENTRING AND SHUTTERING (FORM WORK) Centering and shuttering including strutting, propping etc. and removal of form for 1. Foundations, footings, bases of columns, etc. for mass concrete HSR 6.30 |
| 20 | I CENTRING AND SHUTTERING (FORM WORK) Centering and shuttering including strutting, propping etc. and removal of form for 2. Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc. HSR 6.30 |
| 21 | I CENTRING AND SHUTTERING (FORM WORK) Centering and shuttering including strutting, propping etc. and removal of form for 3. Suspended floors, roofs, landings, balconies and access platform HSR 6.30 |
| 22 | I CENTRING AND SHUTTERING (FORM WORK) Centering and shuttering including strutting, propping etc. and removal of form for 4. Shelves (Cast in situ) HSR 6.30 |
| 23 | I CENTRING AND SHUTTERING (FORM WORK) Centering and shuttering including strutting, propping etc. and removal of form for 5. Lintels, beams, plinth beams, girders, bressumers and cantilevers HSR 6.30 |
| 24 | I CENTRING AND SHUTTERING (FORM WORK) Centering and shuttering including strutting, propping etc. and removal of form for 6. Columns, Pillars, Piers, Abutments, Posts and Struts HSR 6.30 |
| 25 | I CENTRING AND SHUTTERING (FORM WORK) Centering and shuttering including strutting, propping etc. and removal of form for 7. Stairs, (excluding landings) except spiral-staircases HSR 6.30 |
| 26 | I CENTRING AND SHUTTERING (FORM WORK) Centering and shuttering including strutting, propping etc. and removal of form for 16.1. Edges of slabs and breaks in floors and wallsUnder 20 cm wide HSR 6.30 |
| 27 | I CENTRING AND SHUTTERING (FORM WORK) Centering and shuttering including strutting, propping etc. and removal of form for 19. Weather shade, Chajjas, corbels etc., including edges HSR 6.30 |
| 28 | I CENTRING AND SHUTTERING (FORM WORK) Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc., including cost of de-shuttering and decentring at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan area to be measured). 1. Suspended floors, roofs, landing, beams and balconies (Plan area to be measured) HSR 6.32 |
| 29 | J STEEL REINFORCEMENT Steel reinforcement for R.C.C. work, where not included in the complete rate of RCC, including straightening, cutting, bending, placing in position, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. complete in all respect above plinth level Note:- Reinforcement shall be measured in length including hooks, if any, separately for different diameters as actually used in work , excluding overlaps. Wastage, overlaps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods of binding & placing shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement. 6. Thermo-Mechanically Treated bars of grade Fe-500D or more. HSR 6.34 |
| 30 | B BRICK WORK Brick work with common burnt clay non-modular bricks of class designation 10.5 in foundation and plinth in: 1. Cement mortar 1:4 (1 cement : 4 coarse sand) HSR 7.21 |
| 31 | B BRICK WORK Brick work with common burnt clay non-modular bricks of class designation 10.5 in superstructure above plinth level up to floor IV level in all shapes and sizes in : 1. Cement mortar 1:4 (1 cement : 4 coarse sand) HSR 7.22 |
| 32 | HALF BRICK MASONRY Half brick masonry with common burnt clay non-modular bricks of class designation 10.5 in superstructure above plinth level up to floor IV level. 2. Cement mortar 1:4 (1 cement :4 coarse sand) HSR 7.28 |
| 33 | HALF BRICK MASONRY Extra for half brick masonry in superstructure, above floor IV level for every three floors or part thereof by mechanical means. HSR 7.29 |
| 34 | HALF BRICK MASONRY Extra for providing and placing in position 2 Nos. 6mm dia. M.S. bars at every third course of half brick masonry. HSR 7.3 |
| 35 | EXPOSED BRICK WALL Providing and laying autoclaved aerated cement blocks masonry with 150mm/230mm/300 mm thick AAC blocks in super structure above plinth level up to floor IV level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for separately). HSR 7.51 |
| 36 | VENEERING WORK Providing and fixing plywood 4 mm thick, one side decorative veneer conforming to IS: 1328 (type-1), for plain lining / cladding with necessary screws, including priming coat on unexposed surface with : 1. Decorative veneer facings of approved manufacture HSR 8.19 |
| 37 | KITCHEN PLATEFORMS/ WINDOW SILLS/ URINAL PARTITIONS Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. 2.2. Granite of any colour and shadeArea of slab over 0.50 sqm HSR 8.26 |
| 38 | KITCHEN PLATEFORMS/ WINDOW SILLS/ URINAL PARTITIONS Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. 2. Granite work HSR 8.27 |
| 39 | KITCHEN PLATEFORMS/ WINDOW SILLS/ URINAL PARTITIONS Extra for providing opening of required size and shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. HSR 8.28 |
| 40 | ALUMINIUM COMPOSITE PANELS ALUMINIUM COMPOSITE PANELSDesigning, fabricating, testing, installing and fixing in position Curtain Wall with Aluminium Composite Panel Cladding, with open grooves for linear as well as curvilinear portions of the building , for all heights and all levels etc. including:(a) Structural analysis and design and preparation of shop drawings for pressure equalisation or rain screen principle as required, proper drainage of water to make it watertight including checking of all the structural and functional design.(b) Providing, fabricating and supplying and fixing panels of aluminium composite panel cladding in pan shape in metallic colour of approved shades made out of 4mm thick aluminium composite panel material consisting of 3mm thick FR grade mineral core sandwiched between two Aluminium sheets (each 0.5mm thick). The aluminium composite panel cladding sheet shall be coil coated, with Kynar 500 based PVDF / Lumiflon based fluoropolymer resin coating of approved colour and shade on face # 1 and polymer (Service) coating on face # 2 as specified using stainless steel screws, nuts, bolts, washers, cleats, weather silicone sealant, backer rods etc.(c) The fastening brackets of Aluminium alloy 6005 T5 / MS with Hot Dip Galvanised with serrations and serrated washers to arrest the wind load movement, fasteners, SS 316 Pins and anchor bolts of approved make in SS 316, Nylon separators to prevent bi-metallic contacts all complete required to perform as per specification and drawing The item includes cost of all material and labour component, the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working curtain wall with aluminium composite panel cladding, cleaning and protection of the curtain wall with aluminium composite panel cladding till the handing over of the building for occupation. Base frame work for ACP cladding is payable under the relevant aluminium items. The Contractor shall provide curtain wall with aluminium composite panel cladding, having all the performance characteristics all complete , as per the Architectural drawings, as per item , as specified, as per the approved shop drawings and as directed by the Engineer-in-Charge. However, for the purpose of payment, only the actual area on the external face of the curtain wall with Aluminium Composite Panel Cladding (including width of groove) shall be measured in sqm up to two decimal places. HSR 8.32 |
| 41 | KITCHEN PLATEFORMS/ WINDOW SILLS/ URINAL PARTITIONS Providing and fixing facing extruded clay Tile (Glass Reinforced Clay Tiles (GRC)) any size any shade and design on wall with under layer of 12 mm thick cement plaster 1:3 and jointed withneat cement matched with pigment complete as per drawings, specifications and to the entire satisfaction of engineer- in- charge. HSR 8.31 |
| 42 | B ROOFING Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : 1. In 75x75 mm deep chase HSR 9.17 |
| 43 | B ROOFING Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. HSR 9.18 |
| 44 | CEILING Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts and bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering up to 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer`s specification and also including the cost of making openings for light fittings, grills, diffusers, cut outs made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : 1. 12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) :2011 (Board with BIS certification marks) HSR 9.46 |
| 45 | CEILING Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts and bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering up to 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer`s specification and also including the cost of making openings for light fittings, grills, diffusers, cut outs made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : 3. 12.5 mm thick tapered edge gypsum moisture resistant board HSR 9.46 |
| 46 | RAIN WATER SPOUTS AND PIPES Providing and fixing on wall face Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 2. 110 mm diameter HSR 9.57 |
| 47 | RAIN WATER SPOUTS AND PIPES Providing and fixing on wall face Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 3. 150 mm diameter HSR 9.57 |
| 48 | RAIN WATER SPOUTS AND PIPES Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 1.2. Coupler 110 mm HSR 9.58 |
| 49 | RAIN WATER SPOUTS AND PIPES Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 1.3. Coupler 150 mm HSR 9.58 |
| 50 | RAIN WATER SPOUTS AND PIPES Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 3.2. Single tee with door110x110x110 mm HSR 9.58 |
| 51 | RAIN WATER SPOUTS AND PIPES Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 3.3. Single tee with door150x150x150 mm HSR 9.58 |
| 52 | RAIN WATER SPOUTS AND PIPES Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 5.2. Bend 87.5°110 mm bend HSR 9.58 |
| 53 | RAIN WATER SPOUTS AND PIPES Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 5.3. Bend 87.5°150 mm bend HSR 9.58 |
| 54 | RAIN WATER SPOUTS AND PIPES Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 6.3. Shoe (Plain)150 mm Shoe HSR 9.58 |
| 55 | RAIN WATER SPOUTS AND PIPES Providing and fixing Unplasticised -PVC pipe clips of approved design to Unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 2. 110 mm HSR 9.59 |
| 56 | RAIN WATER SPOUTS AND PIPES Providing and fixing Unplasticised -PVC pipe clips of approved design to Unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 3. 150 mm HSR 9.59 |
| 57 | CEMENT CONCRETE FLOORING Supplying and providing of Tangri River Sand under floors Including watering and compaction in 25cm layers, dressing etc. complete In all respects (As per item 10.2) HSR 10.3 |
| 58 | CEMENT CONCRETE FLOORING Providing and laying of screed of 50 mm thick cement concrete 1:8:16 to be laid below the topping. HSR 10.4 |
| 59 | CEMENT CONCRETE FLOORING Providing and laying of conglomerate floor 40mm thick cement concrete topping 1:2:4 HSR 10.8 |
| 60 | CEMENT CONCRETE FLOORING Providing and laying of Conglomerate floor 25 mm thick cement concrete 1:2:4 on 100 mm cement concrete 1:8:16 and 100 mm sand or stone filling. HSR 10.9 |
| 61 | CEMENT CONCRETE FLOORING Providing and laying Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 2. 25 mm thick with 12 mm nominal size stone aggregate HSR 10.10 |
| 62 | TILE FLOORING Providing and laying of chequered precast cement concrete tiles 22 mm thick in footpath and courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). 3. Dark shade pigment using ordinary cement HSR 10.30 |
| 63 | GRANITE FLOORING Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. 1. Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. HSR 10.50 |
| 64 | GRANITE FLOORING Providing and fixing granite stone in all shades 15mm to 18 mm thick in skirting /dado, risers of steps, pillars and wall facing, laid in any pattern as specified over base of 12mm thick cement coarse sand mortar 1:3 and jointed with white cement slurry mixed with pigment to match the shade of Granite including labour for fixing cramps pins and dowels etc. HSR 10.51 |
| 65 | VITRIFIED FLOOR TILES Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. 2. Size of Tile 600x600 mm HSR 10.63 |
| 66 | VITRIFIED FLOOR TILES Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours and shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement and matching pigments etc. complete. 2. Size of Tile 600x600 mm HSR 10.67 |
| 67 | VITRIFIED FLOOR TILES Extra for grouting the joints of floor tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. 2. Size of Tile 600x600 mm HSR 10.70 |
| 68 | VITRIFIED FLOOR TILES Providing and fixing ceramic and Glazed tiles/ vitrified tiles/ of any size of approved make in floors / dados, laid in any pattern as specified over base of 3 mm thick adhesive of reputed brands as per IS specification 15477-2004 using 5 Kg. adhesive per sqm area of tiles and jointed with white cement slurry mixed with pigment to match the shade of tiles excluding cost of tiles. HSR 10.73 |
| 69 | FLOORING and DADOS Providing and fixing in position Phenol bonded Bamboo wood flooring with planks of sizes 14mm thick, 1800mm length (minimum) and 130 mm wide(minimum), in approved colour, texture and finish, having Performance Appraisal Certificate (PAC) issued by Building Materials and Technology Promotion Council (BMTPC). The flooring shall be fixed with tongue and groove interlocking system, with underlayment of 4mm thick expanded polyethylene foam sheets having density 40kg/cum, over prepared surface with necessary quarter round planks of size 1900mm x 18mm and door reducer of size 1900mm x 44mm, wherever required. The bamboo wood planks shall have minimum density of 1000 kg/cum and minimum Hardness 1000 kgf. with Eco friendly UV coating, all complete as per direction of the Engineer in-charge. HSR 18.7 |
| 70 | GI PIPES Making chases up to 7.5x7.5 cm in walls including making good and finishing with matching surface after housing G.I. pipe etc. HSR 22.9 |
| 71 | CEMENT PLASTER (IN FINE SAND) 10 mm thick cement plaster 2. 1:3 (1 cement: 3 fine sand) HSR 11.4 |
| 72 | CEMENT PLASTER (IN FINE SAND) 12 mm cement plaster of mix : 4. 1:6 (1 cement: 6 fine sand) HSR 11.5 |
| 73 | CEMENT PLASTER (IN FINE SAND) 15 mm cement plaster on the rough side of single or half brick wall of mix : 1. 1:4 (1 cement: 4 fine sand) HSR 11.6 |
| 74 | CEMENT PLASTER WITH A FLOATING COAT OF NEAT CEMENT Providing and fixing of chicken wire mesh for avoiding cracks in plaster with necessary nail/screws etc. complete in all respect to the entire satisfaction of engineer-in-charge HSR 11.17 |
| 75 | RENDERING ON RCC SURFACE Smooth finishing of the exposed surface of R.C.C. work with 10 mm thick cement mortar 1:4 (1 Cement : 4 fine sand). HSR 11.51 |
| 76 | RENDERING ON RCC SURFACE Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections. HSR 11.54 |
| 77 | INTERIOR FINISHING Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. HSR 11.60 |
| 78 | INTERIOR FINISHING Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer`s specification. 1. Two or more coats on new work HSR 11.65 |
| 79 | INTERIOR FINISHING Preparation of ply wood surface for painting including sand papering the surface and applying filling with approved quality filler consisting of white lead, linseed oil, varnish and chalk mitti including finishing the surface to required finish complete. HSR 11.76 |
| 80 | INTERIOR FINISHING Painting two coats excluding priming coat with synthetic enamel paint in all shades on new wood work or metallic or plastered or concrete surfaces to give an even shade. HSR 11.78 |
| 81 | INTERIOR FINISHING Melamine polishing on wood work (one or more coat). HSR 11.91 |
| 82 | EXTERIOR FINISHING WALL AND ROOF SURFACES Finishing walls with textured exterior paint of required shade : 1. New work (Two or more coats applied @ 3.28 litre/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm HSR 11.94 |
| 83 | EXTERIOR FINISHING WALL AND ROOF SURFACES Finishing walls with Acrylic Smooth exterior paint of required shade : 1. New work (Two or more coat applied @ 1.67 litre/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) HSR 11.95 |
| 84 | A DOOR FRAMES, SHUTTERS AND WINDOWS Providing wood work in frames of false ceiling, partitions etc. sawn and fixed in position with necessary stainless steel screws etc. 4.2. Kiln seasoned and chemically treated Hollock wood HSR 12.4 |
| 85 | CUPBOARD SHUTTERS Providing and fixing flat pressed 3 layer particle board medium density exterior grade (Grade I) or graded wood particle board IS : 3087 marked, to frame, backing or studding with screws etc. complete (Frames, backing or studding to be paid separately):1. 12 mm thick HSR 12.26 |
| 86 | CUPBOARD SHUTTERS Providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm all complete. 2. With 12 mm mild steel U beading HSR 12.33 |
| 87 | FLUSH DOOR SHUTTERS Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 1. 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws HSR 12.36 |
| 88 | STAINLESS STEEL FITTINGS Providing and fixing bright /matt finished Stainless Steel handles of approved quality and make with necessary screws etc all complete. 1. 125 mm HSR 12.75 |
| 89 | HYDRAULIC DOOR CLOSERS Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight up to 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete. HSR 12.89 |
| 90 | ANODISED ALUMINIUM FITTINGS (ALL FITTINGS SHALL BE ISI MARKED) Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : 1. 300x16 mm HSR 12.98 |
| 91 | ANODISED ALUMINIUM FITTINGS (ALL FITTINGS SHALL BE ISI MARKED) Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : 2. 250x16 mm HSR 12.98 |
| 92 | ANODISED ALUMINIUM FITTINGS (ALL FITTINGS SHALL BE ISI MARKED) Providing and fixing 50 cm long aluminium kicking plate of size 100x3.15 mm, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete. HSR 12.101 |
| 93 | ANODISED ALUMINIUM FITTINGS (ALL FITTINGS SHALL BE ISI MARKED) Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. 2. Twin rubber stopper HSR 12.103 |
| 94 | PTMT (Polytetra Methylene Terephthalate) FITTINGS Providing and fixing of roller blinds on windows complete with material and labour complete with push up and down arrangement as per approved design / colour and Engineer-in-charge. HSR 12.114 |
| 95 | B PVC Work Providing and fixing of casement and fixed windows made from multi chambered UPVC profiles of 56 to 68mm width in natural from stabilized for heat, light, impact and UV radiation The UPVC profiles should be reinforced with galvanized steel profiles of designed thickness. All openable sashes shall be having weather seal fitted in continuous lengths made from Bubble EPOM Rubber and side hung/ top hung with up to 90 degree opening friction stays of SS 304 with provision of multipoint locking system made from Espag rods. All handle shall be made from Die Cast Zinc alloy (Model ESPAG)BS-1004A in white finish with suitable locking arrangement. The windows shall be fixed to opening using expandable screws and friction stays that shall be able to with stand wind speeds up to 180 km/hr. the shoot bolts in windows shall be rust proof metallic coated steel. The window frames shall be fixed in masonry wall RCC with necessary fasteners, nuts, bolts, washers, caps, silicon sealant etc. complete 1. Frame work HSR 12.130 |
| 96 | B PVC Work Providing and fixing of casement and fixed windows made from multi chambered UPVC profiles of 56 to 68mm width in natural from stabilized for heat, light, impact and UV radiation The UPVC profiles should be reinforced with galvanized steel profiles of designed thickness. All openable sashes shall be having weather seal fitted in continuous lengths made from Bubble EPOM Rubber and side hung/ top hung with up to 90 degree opening friction stays of SS 304 with provision of multipoint locking system made from Espag rods. All handle shall be made from Die Cast Zinc alloy (Model ESPAG)BS-1004A in white finish with suitable locking arrangement. The windows shall be fixed to opening using expandable screws and friction stays that shall be able to with stand wind speeds up to 180 km/hr. the shoot bolts in windows shall be rust proof metallic coated steel. The window frames shall be fixed in masonry wall RCC with necessary fasteners, nuts, bolts, washers, caps, silicon sealant etc. complete 2. Openable shutter HSR 12.130 |
| 97 | B PVC Work Providing and fixing of casement and fixed windows made from multi chambered UPVC profiles of 56 to 68mm width in natural from stabilized for heat, light, impact and UV radiation The UPVC profiles should be reinforced with galvanized steel profiles of designed thickness. All openable sashes shall be having weather seal fitted in continuous lengths made from Bubble EPOM Rubber and side hung/ top hung with up to 90 degree opening friction stays of SS 304 with provision of multipoint locking system made from Espag rods. All handle shall be made from Die Cast Zinc alloy (Model ESPAG)BS-1004A in white finish with suitable locking arrangement. The windows shall be fixed to opening using expandable screws and friction stays that shall be able to with stand wind speeds up to 180 km/hr. the shoot bolts in windows shall be rust proof metallic coated steel. The window frames shall be fixed in masonry wall RCC with necessary fasteners, nuts, bolts, washers, caps, silicon sealant etc. complete 3. Double glass glazing comprising of 6 mm thick toughened clear glass + 12mm air gap + 5mm annealed clear glass. HSR 12.130 |
| 98 | B PVC Work Providing and fixing factory made uPVC white colour casement/casement cum fixed glazed windows comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape and size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, stainless steel (SS 304 grade) friction hinges, zinc alloy (white powder coated) casement handles, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame and sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware`s and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing and direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately). Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. 1. Casement window single panel with S.S. friction hinges (300 x 19 x 1.9 mm), made of (small series) frame 47 x 50 mm & sash 47 x 68 mm both having wall thickness of 1.9 ± 0.2 mm and single glass pane glazing bead of appropriate dimension. (Area of window up to 0.75 sqm) HSR 12.131 |
| 99 | FRP DOOR/WINDOW FRAMES AND SHUTTERS Providing and fixing fire resistant door frame of section 143 x 57 mm having built in rebate made out of 16 SWG G.I. sheet (zinc coating not less than 120 gm/sqm) duly filled with vermiculite based concrete mix, suitable for mounting 60 minutes fire rated door shutters. The frame is fitted with intumuscent fire seal strip of size 10x4 mm (minimum) all-round the frame and fixing with dash fastener of approved size and make, including applying a coat of approved brand fire resistant primer etc. complete as per direction of Engineer-in-charge (Dash fastener to be paid for separately). HSR 12.147 |
| 100 | FRP DOOR/WINDOW FRAMES AND SHUTTERS Providing and fixing 50 mm thick glazed fire resistant door shutters of 60 minutes fire rating conforming to IS:3614 (Part-II), tested and certified as per laboratory approved by Engineer-in-charge, with suitable mounting on door frame, consisting of vertical styles, lock rail, top rail 100 mm wide, bottom rail 200 mm wide, made out of 16 SWG G.I.sheet (zinc coating not less than 120 gm/m2) duly filled FR insulation material and fixing with necessary stainless steel ball bearing hinges of approved make, including applying a coat of approved fire resistant primer etc. all complete as per direction of Engineer-in-charge (panelling to be paid for separately). HSR 12.148 |
| 101 | FRP DOOR/WINDOW FRAMES AND SHUTTERS Providing and fixing glazing in fire resistant door shutters, fixed panels and partitions etc., with G.I. beading made out of 1.6 mm thick G.I. sheet (zinc coating not less than 120 gm/m²) of size 20 x 33 mm screwed with M4 x 38 mm SS screws at distance 75 mm from the edges and 150 mm c/c , including applying a coat of approved fire resistant primer/powder coating of not less than 30 micron on G.I. beading, and special ceramic tape of 5 x 20 mm size etc complete in all respect as per NBC 2016, IS 16231 (Part 3):2016 and as per direction of Engineer-in-charge with glass of required thickness having 60 minutes of fire resistance both integrity and radiation control (EW60) and minimum 20 minutes of insulation (EI20). The manufacturer have to give test report/certification of fire glass and the glass should have the stamp showing the value of E, EW and EI. The glass shall be tested in approved NABL accredited lab or by any other accreditation body which operates in accordance with ISO/IEC 17011 and accredits labs as per ISO/IEC 17025 for testing and calibration scopes shall be eligible. The maximum glazing size shall not be more than 1100x2200 mm (w x h) or 2.42 sqm HSR 12.149 |
| 102 | FRP DOOR/WINDOW FRAMES AND SHUTTERS Providing and fixing panic bar / latch (Double point) fitted with a single body, Trim Latch and Lock on back side of the Panic Latch of reputed brand and manufacture to be approved by the Engineer- in- charge, all complete. HSR 12.150 |
| 103 | C ALUMINIUM WORK Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, panelling and dash fasteners to be paid for separately) : 1.2. For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron) HSR 12.157 |
| 104 | C ALUMINIUM WORK Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, panelling and dash fasteners to be paid for separately) : 2.2. For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron) HSR 12.157 |
| 105 | C ALUMINIUM WORK Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminium doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge. 2. Pre-laminated particle board with decorative lamination on both sides HSR 12.158 |
| 106 | C ALUMINIUM WORK Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): 3. With float glass panes of 6 mm thickness (weight not less than 15 kg/sqm) HSR 12.159 |
| 107 | C ALUMINIUM WORK Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight up to 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge. 1. With stainless steel cover plate minimum 1.25 mm thickness HSR 12.160 |
| 108 | C ALUMINIUM WORK Providing and fixing aluminium tubular handle bar 32 mm outer dia, 3.0 mm thick and 2100 mm long with SS screws etc .complete as per direction of Engineer-in-Charge. 3. Polyester powder coated minimum thickness 50 micron aluminium tubular handle bar HSR 12.163 |
| 109 | C ALUMINIUM WORK Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top and bottom pivot and double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge (Door handle, lock and stopper etc.to be paid separately). HSR 12.171 |
| 110 | STEEL DOOR/ WINDOW FRAMES AND SHUTTERS Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 2.0 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 2.00 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge: 1.1. Profile B Fixing with adjustable lugs with split end tail to each jamb HSR 13.3 |
| 111 | SIGLE/BUILT-UP STEEL/TUBULAR SECTIONS Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. 2. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works HSR 13.29 |
| 112 | SIGLE/BUILT-UP STEEL/TUBULAR SECTIONS Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. 2. Hot finished seamless type tubes HSR 13.30 |
| 113 | ROLLING/COLLAPSIBLE/SLIDING DOOR SHUTTERS Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 1. 80x1.25 mm M.S. laths with 1.25 mm thick top cover HSR 13.37 |
| 114 | ROLLING/COLLAPSIBLE/SLIDING DOOR SHUTTERS Providing and fixing ball bearing for rolling shutters. HSR 13.38 |
| 115 | STAINLESS STEEL RAILING Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories and stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). HSR 13.41 |
| 116 | WATERPROOFING TREATMENT TO RETAINING WALL AREA FROM EXTERNAL SIDE USING LIQUID APPLIED SINGLE COMPONENTPITCH FREE POLYURETHANE COATING `Providing and applying waterproofing treatment to sound, moisture free concrete surface using liquid applied single component pitch free polyurethane coating capable of bridging substrate cracks up to 2 mm. It shall be applied in two coats at coverage rate of 2kg/sqm to a achieve a minimum DFT of 1.3 mm. The membrane formed shall confirm to following minimum properties:1) Elongation : )400% as per ASTM D 4122) Tensile Strength : 2.5 N/mm2 as per ASTM D 4123) Adhesion in-peel test : )50 N as per ASTM C- 8364) Recovery from 350% elongation : 95% as per ASTM D 4125) Water Vapour Transmission 2.3mm film: 0.6 g/m2/hr6) Initial Hardness Shore A : min 60 as per ASTM D 22407) Root resistant : protection screed requiredSystem includes supply , application and termination of coating all complete as per the manufacturer methodology.Clean the RCC slab/screed surface and wall for treatment by removing dust, dirt and layers of concrete over the surface. etc. by mechanical tools and wire brushing. Pressure grouting at construction joints or honeycombs with non shrink cementations grout by mixing shrinkage compensating admixture per bag of cement as per manufacturer’s recommendations. Providing and applying liquid applied single component pitch free polyurethane coating in 2 coats at coverage rate of 2kg/sqm to a achieve a minimum DFT of 1.3 mm. (Fibre cloth/fleece/reinforcement should not be used in between two coats of PU as it has adverse effect on elongation property and also affects bonding with slab). Termination shall be done 300 mm above vertical wall by providing a groove cut of 30mm x 30mm and seal it with shrinkage compensated polymer modified mortar. Membrane shall be protected using 8mm thick dimple board for protection as per manufacturer`s recommendation followed by backfilling. The rates are inclusive of surface preparation, crack filling, injection grouting at honeycombed areas, coving, priming all complete as per manufacturer methodology but excluding the cost of protection board.` HSR 28.12 |
| 117 | WATERPROOFING TREATMENT TO RETAINING WALL AREA FROM EXTERNAL SIDE USING LIQUID APPLIED SINGLE COMPONENTPITCH FREE POLYURETHANE COATING Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of:(i) Ist course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface.(ii) IInd course of 20 mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface.(iii) IIIrd course of applying blown or residual bitumen applied hot at 1.7 kg. per sqm of area.(iv) IVth course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/sqm). HSR 28.14 |
| 118 | WATERPROOFING TREATMENT TO RETAINING WALL AREA FROM EXTERNAL SIDE USING LIQUID APPLIED SINGLE COMPONENTPITCH FREE POLYURETHANE COATING Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying:(a) after surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm(b) laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm.(c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken up to 30 cm on parapet wall and tucked into groove in parapet all around.(d) fourth and final layer of brick tiling with cement mortar (which will be paid for separately). For the purpose of measurement the entire treated surface will be measured. HSR 28.16 |
| 119 | WATERPROOFING TREATMENT TO RETAINING WALL AREA FROM EXTERNAL SIDE USING LIQUID APPLIED SINGLE COMPONENTPITCH FREE POLYURETHANE COATING Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservoir, sewage and water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fibre brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e. by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage. 2. For horizontal surface one coat @1.10 kg per sqm HSR 28.20 |
| 120 | Thermal Insulation of Buildings Providing and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) ) 78, solar reflection ) 0.70 and initial emittance ) 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement and marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm height along the parapet walls in the same manner. HSR 28.50 |
| 121 | POLYURETHANE FOAM (PUF) INSULATION Providing and fixing extruded polystyrene (XPS) foam 50mm thick of density 32 Kg./ cum for thermal insulation with cramps of GI strip 25mm wide x 3mm thick fixed with screw/ nail for holding the walls at regular intervals in cavity walls complete in all respect. HSR 28.52 |
| 122 | Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved shop drawings , the aluminium quality as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. ( The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account). The weight of aluminium extruded section shall be taken for purpose of payment. HSR 29.1 |
| 123 | Providing, assembling and supplying vision glass panels (IGUs) comprising of hermetically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade, an inner Heat strengthened clear float glass 6mm thick, spacer tube 12mm wide, desiccants, including primary seal and secondary seal (structural silicone sealant) etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge. The IGUs shall be assembled in the factory/ workshop of the glass processor.(Payment for fixing of IGU Panels in the curtain glazing is included in cost of item No.29.6)For payment, only the actual area of glass on face # 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm(i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face # 2, plus 12mm Air gap plus 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement. HSR 29.2 |
| 124 | Extra for openable side / top hung vision glass panels (IGUs) including providing and supplying at site all accessories and hardwares for the openable panels as specified and of the approved make such as heavy duty stainless steel friction hinges, min 4 -point cremone locking sets with stainless steel plates, handles, buffers etc. including necessary stainless steel screws/ fasteners, nuts, bolts, washers etc. all complete as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer- in-Charge. HSR 29.3 |
| 125 | Providing, fabricating and supplying shadow box of required size and shape, for fixing in the spandrel portion of the structural glazing, in linear as well as curvilinear portions of the building by providing semi -rigid, inorganic, non-combustible fibre glass wool insulation 50 mm thick, conforming to IS: 8183 and BS: 3958 Part 5. The insulation layer shall have facing (factory bonded on surface # 1 of the fibre glass insulation layer), of black non-woven fibre glass tissue of nominal thickness 0.5 mm and nominal mass not less than 60 gm /sqm, made of randomly oriented glass fibres distributed in a binder by a wet-lay process including fixing 1.5 mm thick solid aluminium sheet backing using, 6 mm thick cement board including SS rivets, nuts, bolts, washers etc complete. HSR 29.4 |
| 126 | Providing and supplying Spandrel Glass Panels comprising of 6 mm thick heat strengthened monolithic float glass of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade so as to match the colour and shade of the IGUs in the vision panels etc. ,all complete for the required performances as specified, as per the Architectural drawings, as per the approved shop drawings, as specified, and as directed by the Engineer- in- Charge.For payment, only the actual area of glass on face # 1 of the glass panels (but excluding the area of grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm (Payment for fixing of Spandrel Glass Panels in the curtain glazing is included in cost of relevant Item).“(i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face # 2, having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/m2 K etc. . The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement. HSR 29.5 |
| 127 | Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including:(a) Structural analysis and design and preparation of shop drawings for the specified design loads conforming to IS 875 part III (the system must passed the proof test at 1.5 times design wind pressure without any failure), including functional design of the aluminium sections for fixing glazing panels of various thicknesses, aluminium cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)-cum-smoke seals, microwave cured EPDM gaskets for water tightness, pressure equalisation and drainage and protection against fire hazard including:(b) Fabricating and supplying serrated M.S. hot dip galvanised / Aluminium alloy of 6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3 Dimensional movement for achieving perfect verticality and fixing structural glazing system rigidly to the RCC/ masonry/structural steel framework of building structure using stainless steel anchor fasteners/ bolts, nylon separator to prevent bimetallic contacts with nuts and washers etc. of stainless steel grade 316, of the required capacity and in required numbers.(c) Providing and filling, two part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant of required bite size in a clean and controlled factory / work shop environment, including double sided spacer tape, setting blocks and backer rod, all of approved grade, brand and manufacture, as per the approved sealant design, within and all around the perimeter for holding glass.(d) Providing and fixing in position flashings of solid aluminium sheet 1 mm thick and of sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it watertight.(e) Making provision for drainage of moisture/ water that enters the curtain glazing system to make it watertight, by incorporating principles of pressure equalization, providing suitable gutter profiles at bottom (if required), making necessary holes of required sizes and of required numbers etc. complete. This item includes cost of all inputs of designing, labour for fabricating and installation of aluminium grid, installation of glazed units, TandP, scaffolding and other incidental charges including wastages etc., enabling temporary structures and services, cranes or cradles etc. as described above and as specified. The item includes the cost of getting all the structural and functional design including shop drawings checked by a structural designer, dully approved by Engineer-in-charge. The item also includes the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working structural glazing as specified, cleaning and protection till the handing over of the building for occupation. In the end, the Contractor shall provide a water tight structural glazing having all the performance characteristics etc. all complete as required, as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer- in-Charge. HSR 29.6 |
| 128 | MINERAL FIBRE CEILING TILES Providing and fixing mineral fibre false ceiling tiles at all heights of size 595X595mm of approved texture, design and pattern. The tiles should have Humidity Resistance (RH) of 99%, Light Reflectance = 85%, Thermal Conductivity k = 0.052 -0.057 w/m K, Fire Performance as per (BS 476 pt - 6 and7)in true horizontal level suspended on interlocking T-Grid of hot dipped all round galvanized iron section of 0.33 mm thick (galvanized @120 gsm) comprising of main T runners of 15x32 mm of length 3000 mm, cross T of size 15x32mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item (galvanised@80gsm) 50 mm long 8mm outer diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘T’. The system should rest on periphery walls /partitions with the help of GI perimeter wall angle of size24x24X3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre and 40 mm long dry wall S.S. screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be pre-painted with polyester baked paint, for all heights. The work shall be carried out as per specifications, drawings and as per directions of the engineer-in-charge. 3. With 16 mm thick bevelled tegular mineral fibre Anti-microbial false ceiling tile confirming to ISO 5 (class 100 ) specifications HSR 32.47 |
| 129 | Rebarring work with 10ml inject able mortar epoxy adhesive (Hybrid Urethane Methacrylate adhesive) or chemical compound of make as approved by Engineer-in-Charge complete in all respect including drilling and cost of all materials 0 0 0 4. 16mm dia (hole size 20 mm dia & depth up to 200mm) 0 0 HSR 31.14 |
| 130 | Rebarring work with 10ml inject able mortar epoxy adhesive (Hybrid Urethane Methacrylate adhesive) or chemical compound of make as approved by Engineer-in-Charge complete in all respect including drilling and cost of all materials 0 0 0 5. 20mm dia (hole size 24 mm dia & depth up to 240mm) 0 0 HSR 31.14 |
| 131 | Rebarring work with 10ml inject able mortar epoxy adhesive (Hybrid Urethane Methacrylate adhesive) or chemical compound of make as approved by Engineer-in-Charge complete in all respect including drilling and cost of all materials 0 0 0 6. 25mm dia (hole size 30 mm dia & depth up to 300 mm) 0 0 HSR 31.14 |
| 132 | Rebarring work with 10ml inject able mortar epoxy adhesive (Hybrid Urethane Methacrylate adhesive) or chemical compound of make as approved by Engineer-in-Charge complete in all respect including drilling and cost of all materials 0 0 0 7. 32 mm dia bar hole size 36 mm dia & depth up to 320 mm HSR 31.14 |
| 133 | B ROOFING Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : 1. In 75x75 mm deep chase HSR 9.17 |
| 134 | B ROOFING Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. HSR 9.18 |
| 135 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 1. All kinds of soil. HSR 4.14 |
| 136 | RAIN WATER SPOUTS AND PIPES Providing and fixing on wall face Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 2. 110 mm diameter HSR 9.57 |
| 137 | RAIN WATER SPOUTS AND PIPES Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 5.2. Bend 87.5°110 mm bend HSR 9.58 |
| 138 | RAIN WATER SPOUTS AND PIPES Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 6.2. Shoe (Plain)110 mm Shoe HSR 9.58 |
| 139 | KITCHEN PLATEFORMS/ WINDOW SILLS/ URINAL PARTITIONS Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. 2.2. Granite of any colour and shadeArea of slab over 0.50 sqm HSR 8.26 |
| 140 | KITCHEN PLATEFORMS/ WINDOW SILLS/ URINAL PARTITIONS Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. 2. Granite work HSR 8.27 |
| 141 | KITCHEN PLATEFORMS/ WINDOW SILLS/ URINAL PARTITIONS Mirror polishing on marble work/Granite work/stone work where ever required to give high gloss finish complete. HSR 8.29 |
| 142 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. HSR 4.32 |
| 143 | CEMENT CONCRETE FLOORING Providing and laying of base course of floors consisting of 100 mm thick cement 1:8:16 and 100 mm sand or stone filling. HSR 10.1 |
| 144 | CEMENT CONCRETE FLOORING Providing and laying of base course of floors consisting of 100 mm thick cement 1:8:16 and 100 mm sand or stone filling. 1.1. Re-compacting excavated soil in plinth under floors, including watering, ramming, consolidating and dressing complete. HSR 10.1 |
| 145 | CEMENT PLASTER (IN FINE SAND) 10 mm thick cement plaster 2. 1:3 (1 cement: 3 fine sand) HSR 11.4 |
| 146 | CEMENT PLASTER (IN FINE SAND) 12 mm cement plaster of mix : 4. 1:6 (1 cement: 6 fine sand) HSR 11.5 |
| 147 | STEEL DOOR/ WINDOW FRAMES AND SHUTTERS Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 2.0 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 2.00 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge: 1.1. Profile B Fixing with adjustable lugs with split end tail to each jamb HSR 13.3 |
| 148 | TILE FLOORING Providing and laying of chequered terrazzo tiles 20 to 22 mm thick with graded marble chips of size up to 6 mm in floors, jointed with neat cement slurry mixed with pigment to match the shade of the tiles, including rubbing and polishing complete, on 20 mm thick bed of cement mortar 1:4 (1 cement :4 coarse sand) : 2. Medium shade pigment using 50% white cement, 50% ordinary cement HSR 10.29 |
| 149 | GRANITE FLOORING Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. 1. Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. HSR 10.50 |
| 150 | GRANITE FLOORING Providing and fixing granite stone in all shades 15mm to 18 mm thick in skirting /dado, risers of steps, pillars and wall facing, laid in any pattern as specified over base of 12mm thick cement coarse sand mortar 1:3 and jointed with white cement slurry mixed with pigment to match the shade of Granite including labour for fixing cramps pins and dowels etc. HSR 10.51 |
| 151 | PRE-PAINTED / POWDER COATED GALVANISED SHEET DOOR/WINDOW FRAMES AND WINDOW SHUTTERS Supply and fixingWindows frames (Chowkhats) including mullions consisting frame fabricated from sheet roll formed out of 0.58mm thick galvanized sheet (Base steel as per IS 513) with zinc of 120 gm/sqm steel sheet pre coated (as per approved colour) with Polyester paint of 12-16 microns thickness under coat of EPOXY primer and back coat with ALKYD backer of 5-7 microns, total sheet thickness with coating 0.58mm of approved shade, weld less corner assembly with brackets and screws, fixed in position by means of PVC and metal hold fastener with PVC cap complete in all respects as per drawing, design, specification and entire satisfaction of Engineer-in-charge. 1. Windows Outer frame of size 72mm x 55mm and central mullion 72mm x 50mm with Double rebate HSR 13.22 |
| 152 | PRE-PAINTED / POWDER COATED GALVANISED SHEET DOOR/WINDOW FRAMES AND WINDOW SHUTTERS Supply and fixingWindows frames (Chowkhats) including mullions consisting frame fabricated from sheet roll formed out of 0.58mm thick galvanized sheet (Base steel as per IS 513) with zinc of 120 gm/sqm steel sheet pre coated (as per approved colour) with Polyester paint of 12-16 microns thickness under coat of EPOXY primer and back coat with ALKYD backer of 5-7 microns, total sheet thickness with coating 0.58mm of approved shade, weld less corner assembly with brackets and screws, fixed in position by means of PVC and metal hold fastener with PVC cap complete in all respects as per drawing, design, specification and entire satisfaction of Engineer-in-charge 1. Glazed Windows shutter section 47mm x 20mm (Without Glass) HSR 13.23 |
| 153 | PRE-PAINTED / POWDER COATED GALVANISED SHEET DOOR/WINDOW FRAMES AND WINDOW SHUTTERS Supply and fixingWindows frames (Chowkhats) including mullions consisting frame fabricated from sheet roll formed out of 0.58mm thick galvanized sheet (Base steel as per IS 513) with zinc of 120 gm/sqm steel sheet pre coated (as per approved colour) with Polyester paint of 12-16 microns thickness under coat of EPOXY primer and back coat with ALKYD backer of 5-7 microns, total sheet thickness with coating 0.58mm of approved shade, weld less corner assembly with brackets and screws, fixed in position by means of PVC and metal hold fastener with PVC cap complete in all respects as per drawing, design, specification and entire satisfaction of Engineer-in-charge 2. Wire Mesh Windows shutter Section 40mm x 20mm with S.S wire mesh 32 gauge fly mesh with 144 holes per square Inch HSR 13.23 |
| 154 | PRE-PAINTED / POWDER COATED GALVANISED SHEET DOOR/WINDOW FRAMES AND WINDOW SHUTTERS Supply and fixingWindows frames (Chowkhats) including mullions consisting frame fabricated from sheet roll formed out of 0.58mm thick galvanized sheet (Base steel as per IS 513) with zinc of 120 gm/sqm steel sheet pre coated (as per approved colour) with Polyester paint of 12-16 microns thickness under coat of EPOXY primer and back coat with ALKYD backer of 5-7 microns, total sheet thickness with coating 0.58mm of approved shade, weld less corner assembly with brackets and screws, fixed in position by means of PVC and metal hold fastener with PVC cap complete in all respects as per drawing, design, specification and entire satisfaction of Engineer-in-charge 3. Providing & fixing fixed beading 12mm x 12mm for fixed glass ECO fixed gasket (EPDM) HSR 13.23 |
| 155 | PRE-PAINTED / POWDER COATED GALVANISED SHEET DOOR/WINDOW FRAMES AND WINDOW SHUTTERS Providing and fixingglazing in door, window, ventilator shutters and partitions etc. complete as per the architectural drawings and the directions of engineer-in-charge. (Cost of Gasket / beading shall be paid as per respective item) 1. Float glass panes of 5.5mm thickness HSR 13.24 |
| 156 | VITRIFIED FLOOR TILES Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. 2. Size of Tile 600x600 mm HSR 10.63 |
| 157 | VITRIFIED FLOOR TILES Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours and shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement and matching pigments etc. complete. 2. Size of Tile 600x600 mm HSR 10.67 |
| 158 | VITRIFIED FLOOR TILES Providing and fixing ceramic and Glazed tiles/ vitrified tiles/ of any size of approved make in floors / dados, laid in any pattern as specified over base of 3 mm thick adhesive of reputed brands as per IS specification 15477-2004 using 5 Kg. adhesive per sqm area of tiles and jointed with white cement slurry mixed with pigment to match the shade of tiles excluding cost of tiles. HSR 10.73 |
| 159 | RENDERING ON RCC SURFACE Smooth finishing of the exposed surface of R.C.C. work with 10 mm thick cement mortar 1:4 (1 Cement : 4 fine sand). HSR 11.51 |
| 160 | INTERIOR FINISHING Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. HSR 11.60 |
| 161 | INTERIOR FINISHING Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer`s specification. 1. Two or more coats on new work HSR 11.65 |
| 162 | INTERIOR FINISHING Preparation of ply wood surface for painting including sand papering the surface and applying filling with approved quality filler consisting of white lead, linseed oil, varnish and chalk mitti including finishing the surface to required finish complete. HSR 11.76 |
| 163 | INTERIOR FINISHING Applying pink primer or aluminium priming coat on wood work including preparation of surface, Knotting and stopping etc. HSR 11.77 |
| 164 | INTERIOR FINISHING Painting two coats excluding priming coat with synthetic enamel paint in all shades on new wood work or metallic or plastered or concrete surfaces to give an even shade. HSR 11.78 |
| 165 | EXTERIOR FINISHING WALL AND ROOF SURFACES Finishing walls with Acrylic Smooth exterior paint of required shade : 1. New work (Two or more coat applied @ 1.67 litre/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) HSR 11.95 |
| 166 | FLUSH DOOR SHUTTERS Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 1. 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws HSR 12.37 |
| 167 | STAINLESS STEEL FITTINGS Providing and fixing bright /matt finished Stainless Steel handles of approved quality and make with necessary screws etc all complete. 1. 125 mm HSR 12.75 |
| 168 | HYDRAULIC DOOR CLOSERS Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight up to 35 kg and door width up to 700 mm), with necessary accessories and screws etc. complete. HSR 12.88 |
| 169 | ANODISED ALUMINIUM FITTINGS (ALL FITTINGS SHALL BE ISI MARKED) Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 1. 300x10 mm HSR 12.99 |
| 170 | ANODISED ALUMINIUM FITTINGS (ALL FITTINGS SHALL BE ISI MARKED) Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 3. 200x10 mm HSR 12.99 |
| 171 | ANODISED ALUMINIUM FITTINGS (ALL FITTINGS SHALL BE ISI MARKED) Providing and fixing bright finished brass 100 mm mortice latch and lock, ISI marked, with six levers and a pair of anodised (anodic coating not less than grade AC 10 as per IS : 1868) aluminium lever handles of approved quality with necessary screws etc. complete. HSR 12.105 |
| 172 | WATERPROOFING TREATMENT TO RETAINING WALL AREA FROM EXTERNAL SIDE USING LIQUID APPLIED SINGLE COMPONENTPITCH FREE POLYURETHANE COATING Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying:(a) after surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm(b) laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm.(c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken up to 30 cm on parapet wall and tucked into groove in parapet all around.(d) fourth and final layer of brick tiling with cement mortar (which will be paid for separately). For the purpose of measurement the entire treated surface will be measured. HSR 28.16 |
| 173 | Thermal Insulation of Buildings Providing and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) ) 78, solar reflection ) 0.70 and initial emittance ) 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement and marble powder in ratio of 1:1, including rubbing and polishing of the surface up to 3 cuts complete, including providing skirting up to 150 mm height along the parapet walls in the same manner. HSR 28.43 |
| 174 | B BRICK WORK Brick work with common burnt clay non-modular bricks of class designation 10.5 in foundation and plinth in: 1. Cement mortar 1:4 (1 cement : 4 coarse sand) HSR 7.21 |
| 175 | B BRICK WORK Brick work with common burnt clay non-modular bricks of class designation 10.5 in foundation and plinth in: 2. Cement mortar 1:6 (1 cement : 6 coarse sand) HSR 7.21 |
| 176 | B BRICK WORK Brick work with common burnt clay non-modular bricks of class designation 10.5 in superstructure above plinth level up to floor IV level in all shapes and sizes in : 2. Cement mortar 1:6 (1 cement : 6 coarse sand) HSR 7.22 |
| 177 | A CEMENT CONCRETE (CAST IN SITU) Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: 6. 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) HSR 6.1 |
| 178 | B DAMP-PROOF COURSE Providing and laying damp-proof course with cement concrete 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20mm nominal size) 2. 40 mm thick HSR 6.9 |
| 179 | B DAMP-PROOF COURSE Providing and applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with apiece of cloth lightly soaked in kerosene oil. HSR 6.10 |
| 180 | B DAMP-PROOF COURSE 12 mm thick cement plaster damp-proof course 1:3 with 2 coats of bitumen at 1.65 kg. per sqm, laid hot and sanded: 1. Vertical HSR 6.11 |
| 181 | C PLINTH PROTECTION Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling and dressing and finishing the top smooth. HSR 6.13 |
| 182 | F READY MIX CEMENT CONCRETE WITH FLYASH Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work, including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in-charge. 2. All works above plinth level up to floor IV level HSR 6.24 |
| 183 | J STEEL REINFORCEMENT Steel reinforcement for R.C.C. work, where not included in the complete rate of RCC, including straightening, cutting, bending, placing in position, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. complete in all respect above plinth level Note:- Reinforcement shall be measured in length including hooks, if any, separately for different diameters as actually used in work , excluding overlaps. Wastage, overlaps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods of binding & placing shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement. 6. Thermo-Mechanically Treated bars of grade Fe-500D or more. HSR 6.34 |
| 184 | C FIXING INCLUDING CARRIAGE Providing and fixing steel bar embedded plastic steps of size 263mm x 165mm of orange colour, confirming to specification in pump chambers, manholes etc., having minimum 3mm thick polypropylene polymer confirming to is:10910 encapsulated on 12mm dia ribbed steel bars per IS :1786. The rate include cost of setting the same to correct lines and levels duly embedded in 1:2:4 cement concrete including carriage, loading, uploading, stacking, handling, re-handling etc., complete in all respect to the satisfaction of Engineer-in-charge HSR 21.28 |
| 185 | G STONE WARE INTERCEPTING TRAPS, FLAP VALVES, ROAD GULLIES ETC. Fixing cast iron road gully grating and frame complete including carriage from the stores of the Engineer-in-charge of the works, loading, fixing and erecting the same in position to correct lines and levels in 1:2 cement sand mortar and painting of grating and frame with coal tar. HSR 21.48 |
| 186 | C.P.V.C. PIPES Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 2. 20 mm nominal outer dia Pipes HSR 22.85 |
| 187 | M Masonry Chambers Constructing brick masonry inspection Chamber sizes as given below up to 0.60 metre average depth in cement mortar 1:5 lime concrete with 40 per cent lime mortar 2:3 in foundation cement concrete 1:2:4 benching 12mm thick cement plaster 1:2 with a floating coat of 1 mm thick of neat cement R.C.C. 1:2:4 slab 100 mm thick/cement concrete topping, 50mm thick with 455mmx455mm / 455mm x610mm inside light duty C.I. inspection chamber cover and frame weight as per I.S.I. specification painted with 3 coats of black bitumastic superior paint complete as per standard design. 1. Size 450 mm X450 mm inside (with 455 mm x 455 mm cover and frame light duty single seal weighing 20 kg with C.C. topping HSR 21.84 |
| 188 | M Masonry Chambers Constructing brick masonry inspection Chamber sizes as given below up to 0.60 metre average depth in cement mortar 1:5 lime concrete with 40 per cent lime mortar 2:3 in foundation cement concrete 1:2:4 benching 12mm thick cement plaster 1:2 with a floating coat of 1 mm thick of neat cement R.C.C. 1:2:4 slab 100 mm thick/cement concrete topping, 50mm thick with 455mmx455mm / 455mm x610mm inside light duty C.I. inspection chamber cover and frame weight as per I.S.I. specification painted with 3 coats of black bitumastic superior paint complete as per standard design. 3. Size 600 mm X900 mm inside (with 455 mm x 455 mm cover and frame light duty single seal weighing 20 kg with R.C.C. slab) HSR 21.84 |
| 189 | M Masonry Chambers Constructing brick masonry road gully chambers as per standard drawings (as per sizes given below) including dressing of beds and sides of chambers to exact profiles, 15cm thick lime concrete 16:24:100 (as per specified in item No.10.6) in foundations 1st class brick work laid in cement sand mortar 1:5, 40 mm thick cement concrete 1:2:4 topping inside the chamber with a floating coat of 1.5mm thick neat cement laid in one operation to the topping, the entire inner surface of the chamber rendered with neat cement not less than 12mm in thickness of 1:2 cement sand plaster and finished with floating coat of neat cement 1 mm thick left absolutely smooth polished and correct to templates including labour for fixing the C.I. road gully grating and frame including painting with coal tar (as Specified in item No. Item 21.48) complete to the requirement of the Engineer in-charge 1.1. Single road gully chamber - Size: 610mm x 457mm x 800mm HSR 21.87 |
| 190 | F CUTTING HOLES IN WALLS / FLOORS / ROOFS Cutting holes up to 23 cm through stone masonry or brick work in cement walls for pipes and making good including repointing, replastering and finishing according to existing finish where required. 1. 11.43 cm thick wall HSR 20.26 |
| 191 | F CUTTING HOLES IN WALLS / FLOORS / ROOFS Cutting holes up to 23 cm through stone masonry or brick work in cement walls for pipes and making good including repointing, replastering and finishing according to existing finish where required. 2. 22.86 cm thick wall HSR 20.26 |
| 192 | F CUTTING HOLES IN WALLS / FLOORS / ROOFS Cutting holes up to 23 cm square for pipes in floor and roofs of cement concrete reinforced concrete or reinforced brick work and making good including, repointing, replastering, replacing bitumen and colour or white washing where required. 3. 150 mm thickness of roof or floor HSR 20.28 |
| 193 | INSTALLATION OF SHALLOW/MEDIUM/DEEP TUBEWELLS AS PER IS 2800:1991 Supplying erection, testing of fully automatic electric control panel board forT/Wells in Pump Chamber consisting of MS sheet of thickness 14 gauge duly painted box type floor mounted made of angle Frame containing 1 no. fully automatic air brake starter suitable for Motor of the following capacity, Min switch of suitable range with HRC fuse, 1 no. volt meter (0 to 500 volts), 1 No.Amp. Meter of 0 to 100 amp. 3 sets of indicating lamp capacitor of suitable capacity and 1 no. single phase preventers with the timer switch including wiring in panel board and suitable electric energy meter wiring in Electric Control Panel Board complete in all respect as per specification given in Schedule No. II, Including MCB, suitable, Capacitor,Wooden Box etc as per siterequirement complete in all respect. 1. 10 HP Motor HSR 20.114 |
| 194 | INSTALLATION OF SHALLOW/MEDIUM/DEEP TUBEWELLS AS PER IS 2800:1991 Supplying, erection, testing and commissioning of horizontal motorpumping set for clear water having head20.00 m as per the indicated requirements of discharge in LPM and power capacityin BHP as per IS marked. 1. Discharge Capacity (LPM) 400 Power Capacity (BHP) 3 HSR 20.115 |
| 195 | N MANHOLE CHAMBERS Providing and fixing SFRC MANHOLE COVERS AND FRAMES MARKED WITH IS: 12592 including setting the same to correct lines and levels in 1:3 cement sand mortar over manhole including carriage loading unloading stacking handling re-handling etc. complete in all respects to the satisfaction to the Engineer-in-charge. 1. Type:- Extra Heavy Duty Set (EHD-35) 560MM Clear Opening HSR 21.93 |
| 196 | Supplying, erection, testing and commissioning of submersible motor pumping set non clog for sewerage having head 10.00 m as per the indicated requirements of discharge in LPM and power capacity in BHP as per IS marked including all accessories (like SS Pipes, SS Chain (Shackle Chain) ,SS Foundation Bolt, complete base frame, Monorail, Chain Guide Line, Auto Compiling, Duct Foot Bend (D/F Bend) etc. complete in allrespect 10. Discharge Capacity (LPM) - 500 Power Capacity (BHP) - 2 HSR 21.104 |
| 197 | WASH BASINS, KITCHEN SINKS AND HARDWARES Providing and fixing white vitreous chinaware pedestal for wash basin completely recessed at the back for the reception of pipes and fittings. HSR 22.5 |
| 198 | WASH BASINS, KITCHEN SINKS AND HARDWARES Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 withC.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required: 2.2. Kitchen sink without drain board610x460 mm bowl depth 200 mm HSR 22.10 |
| 199 | WASH BASINS, KITCHEN SINKS AND HARDWARES Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. 1.1. Semi rigid pipe32 mm dia HSR 22.14 |
| 200 | WASH BASINS, KITCHEN SINKS AND HARDWARES Providing and fixing CP Brass 32mm size Bottle Trap of approved quality and make and as per the direction of Engineer-in-charge. HSR 22.15 |
| 201 | WCs, URINALS AND URINAL PARTITIONS Providing and fixing white vitreous chinaware flat back half stall urinal of size 580x380x350 mm with white PVC flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required : 1. Single half stall urinal with 5 litre P.V.C. automatic flushing cistern HSR 22.26 |
| 202 | WCs, URINALS AND URINAL PARTITIONS Providing and fixing white vitreous chinaware extended wall mounting water closet of size 780x370x690 mm of approved shape including providing and fixing white vitreous chinaware cistern / PVC cistern (with brass fitting) into the wall with dual flush fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete. HSR 22.33 |
| 203 | WCs, URINALS AND URINAL PARTITIONS Providing and fixing white vitreous chinaware battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre and post flushing with water (250 ml and 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-charge. HSR 22.46 |
| 204 | WCs, URINALS AND URINAL PARTITIONS Providing and fixing partitions for different type of urinals. 1.1.2. Vitreous Chinaware Partition plate.Small size 680mm x 330 mm Single Colour HSR 22.50 |
| 205 | WCs, URINALS AND URINAL PARTITIONS Providing and fixing partitions for different type of urinals. 1.2.1. Vitreous Chinaware Partition plate.Large size 835mm x 355 mm White HSR 22.50 |
| 206 | C.P.V.C. PIPES Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 1. 15 mm nominal outer dia Pipes HSR 22.86 |
| 207 | C.P.V.C. PIPES Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 2. 20 mm nominal outer dia Pipes HSR 22.86 |
| 208 | C.P.V.C. PIPES Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 3. 25 mm nominal outer dia Pipes HSR 22.86 |
| 209 | C.P.V.C. PIPES Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 4. 32 mm nominal outer dia Pipes HSR 22.86 |
| 210 | C.P.V.C. PIPES Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings This includes jointing of pipes and fittings with one step CPVC solvent cement, trenching, refilling and testing of joints complete as per direction of Engineer in Charge.External work 3. 25 mm nominal outer dia Pipes HSR 22.87 |
| 211 | C.P.V.C. PIPES Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings This includes jointing of pipes and fittings with one step CPVC solvent cement, trenching, refilling and testing of joints complete as per direction of Engineer in Charge.External work 5. 40 mm nominal outer dia Pipes HSR 22.87 |
| 212 | C.P.V.C. PIPES Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings This includes jointing of pipes and fittings with one step CPVC solvent cement, trenching, refilling and testing of joints complete as per direction of Engineer in Charge.External work 6. 50 mm nominal outer dia Pipes HSR 22.87 |
| 213 | GI PIPES Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. Internal work - Exposed on wall 3. 25 mm dia nominal bore HSR 22.88 |
| 214 | GI PIPES Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) : 3. 25 mm nominal bore HSR 22.94 |
| 215 | GI PIPES Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) : 4. 32 mm nominal bore HSR 22.94 |
| 216 | GI PIPES Fixing water meter and stop cock in G.I. pipe line including cutting and threading the pipe and making long screws etc. complete (cost of water meter and stop cock to be paid separately). HSR 22.95 |
| 217 | BRASS FITTINGS Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 2. 20 mm nominal bore HSR 22.98 |
| 218 | BRASS FITTINGS Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 4. 40 mm nominal bore HSR 22.98 |
| 219 | BRASS FITTINGS Providing and fixing Unplasticised PVC connection pipe with brass unions : 2.1. 45 cm length 15 mm nominal bore HSR 22.101 |
| 220 | BRASS FITTINGS Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 2. 20 mm nominal bore HSR 22.103 |
| 221 | BRASS FITTINGS Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 3. 25 mm nominal bore HSR 22.103 |
| 222 | C.P. BRASS FITTINGS Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : 1. 15 mm nominal bore HSR 22.104 |
| 223 | C.P. BRASS FITTINGS Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms. 1. 15 mm nominal bore HSR 22.105 |
| 224 | C.P. BRASS FITTINGS Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. 1. 15 mm nominal bore HSR 22.107 |
| 225 | C.P. BRASS FITTINGS Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 1. 15mm nominal bore HSR 22.108 |
| 226 | C.P. BRASS FITTINGS Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge. HSR 22.109 |
| 227 | C.P. BRASS FITTINGS Providing and fixing chrome plated brass battery based infrared sensor operated pillar cock, having foam flow technology. 1. 15 mm nominal bore HSR 22.110 |
| 228 | WATER SUPPLY, SEWERAGE AND DRAINAGE WORKS Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement and making necessary channels for the drain etc. complete : 1. For pipes 100 to 250 mm diameter HSR 30.88 |
| 229 | STONE WARE PIPES AND FITTINGS Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete : 2. 150 mm diameter HSR 22.163 |
| 230 | STONE WARE PIPES AND FITTINGS Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) up to haunches of S.W. pipes including bed concrete as per standard design : 2. 150 mm diameter S.W. pipe HSR 22.165 |
| 231 | STONE WARE PIPES AND FITTINGS Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: 3.1. 180x150 mm size P typeWith common burnt clay non-modular bricks of class designation 7.5 HSR 22.166 |
| 232 | STONE WARE PIPES AND FITTINGS Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 2. 150 mm dia. R.C.C. pipe HSR 22.168 |
| 233 | SOAK PITS Constructing soak pit 1.20x1.20x1.20 m filled with brickbats including S.W. drain pipe 100 mm diameter and 1.20 m long complete as per standard design. HSR 22.172 |
| 234 | BRICK MASONRY MANHOLES Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (Zone-III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : 2.1. Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (medium duty) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg (weight of cover 58 kg and weight of frame 58 kg) :With common burnt clay non-modular bricks of class designation 7.5 HSR 22.190 |
| 235 | BRICK MASONRY MANHOLES Supplying and fixing C.I. cover 300x300 mm without frame for gully trap (standard pattern) the weight of cover to be not less than 4.5 kg HSR 22.202 |
| 236 | STORM WATER DRAINAGE Constructing brick masonry road gully chamber 50x45x60 cm with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm pre-cast R.C.C. horizontal grating with frame complete as per standard design : 1. With common burnt clay non-modular bricks of class designation 7.5 HSR 22.205 |
| 237 | HDPE pipes for Drainage Providing and fixing in position vitreous chinaware white lavatory suites of approved make (to the approval of Engineer-in-charge) including Rack Bolt Screw Pair 115mm long without CP fittings complete in all respect. 9. Size 560mm x 450mm (Under counter oval) HSR 22.221 |
| 238 | HDPE pipes for Drainage Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 ofE.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. 2.1. Single Socket Type B 160mm o/d SWR UPVC pipe lines laid complete HSR 22.222 |
| 239 | HDPE pipes for Drainage Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 ofE.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. 2.2. Single Socket Type B 110mm o/d SWR UPVC pipe lines laid complete HSR 22.222 |
| 240 | HDPE pipes for Drainage Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 ofE.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. 2.3. Single Socket Type B 90mm o/d SWR UPVC pipe lines laid complete HSR 22.222 |
| 241 | B0229. Galvanised steel J or L hooks 8 mm dia HSR 2 |
| 242 | Excavating trenches of required width and depth for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m. 1.2. All kind of soil Pipes, cables etc, exceeding 80 mm dia but not exceeding 300 mm dia. HSR 4.16 |
| 243 | A CEMENT CONCRETE (CAST IN SITU) Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: 6. 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) HSR 6.1 |
| 244 | B BRICK WORK Brick work with common burnt clay non-modular bricks of class designation 10.5 in foundation and plinth in: 1. Cement mortar 1:4 (1 cement : 4 coarse sand) HSR 7.21 |
| 245 | Supplying at site good earth /soil-less media and/ or organic matter, preparation of top dressing mixture or pot media 0.00 0.00 0.00 1. Supplying at site of work well-decayed farm-yard manure from any available source, approved by the Engineer-in-charge including screening through sieve of I.S.designation 16 mm with 5 km lead and supply of good earth making mixture in ratio of 1:2 HSR 26.3 |
| 246 | Supplying at site good earth /soil-less media and/ or organic matter, preparation of top dressing mixture or pot media 0.00 0.00 0.00 6. Spreading of sludge, farm-yard manure or/and good earth in required thickness (Cost of sludge, farm-yard manure or/and good earth to be paid for separately) HSR 26.3 |
| 247 | Turfing lawns with fine grassing ( selection no.1/ Bermuda and Mexican/Neelgiri grass )including ploughing, dressing including breaking of clods, removal of rubbish, dressing and supplying of selection no. 1 / Bermuda doob grass and Mexican/Neelgiri grass roots, including supplying and spreading of farmyard manure at the rate of 0.60 cum per 100 sqm, maintenance till weed free turf is formed 5. Planting Neelgiri/ Mexican grass roots in rows 5 cm apart in both directions. HSR 26.9 |
| 248 | Digging holes in all kinds of soil, and refilling the same, with the excavated earth, mixed with well decayed farmyard manure (cost of well decayed farm yard manure to be paid separately) 1. Hole 1.2 metre dia and 1.2 metre deep HSR 26.13 |
| 249 | Supply and installation of garden bench 2. Rectangular garden bench with h-shaped sides made of reinforced concrete (M30), thickness 100 mm, back height 750 mm, base width 450 mm. Back and seat shall consist of rectangular reinforced concrete planks 1500 mm x 350 mm x 50 mm. Seating height of the bench shall be 450 mm. The bench shall be fixed with nuts on concrete mount, all holes sealed after assembly and installation. All materials required to be as per BIS specifications. HSR 26.58 |
| 250 | FOLIAGE/SHADE LOVING PLANTS Providing and displaying of Areca Palm plant, having ht. 1.95 m to 2.40 m with 12 to 14 suckers, well developed, fresh and healthy with lush green foliage in 35 cm size of Bucket type cement pots and as per direction of the officer-in-charge. HSR 26.105 |
| 251 | FOLIAGE/SHADE LOVING PLANTS Providing and displaying of Dieffenbachia Tropic-snow plant, having ht. 45 cm and above with 8 - 10 leaves, well developed, fresh and healthy in 20 cm size of Earthen pot/Plastic pot and as per direction of the officer-in-charge. HSR 26.123 |
| 252 | SEASONAL PLANTS Providing and Displaying of Standard Rose (H.T. variety) 3 to 4 healthy branch 90 cm and above ht. well developed with one and above flowers in 25 cm Earthen Pot, as per direction of the officer-in-charge. HSR 26.268 |
| 253 | TREE PLANTS Providing and stacking of Azadirachta indica ( Neem ) of height 120-130cm in big Polybag of size 25 cm as per direction of the officer-in-charge. HSR 26.348 |
| 254 | SHRUBS Providing and stacking of Bauhinia tomentosa (yellow) of height 60-75 cm. in Polybag of size 20 cm as per direction of the officer-in-charge. HSR 26.435 |
| 255 | SHRUBS Providing and stacking of Cestrum nocturnum (Raat ki Rani) of height 60-75 cm. with 4-5 branches in bag of size 25 cm as per direction of the officer-in-charge. HSR 26.446 |
| 256 | SHRUBS `Providing and stacking of Euphorbia pulcherrima (dark red) well branched (poinsettia Red Hegg) of height 60-75 cm. in earthen pots of size 20 cm as per direction of the officer-in- charge.` HSR 26.453 |
| 257 | OTHER MISCELLANEOUS ITEMS USED FOR FLOORING 0 Providing and laying tactile tile (for vision impaired persons as per standards) of size 300x300x9.8mm having with water absorption less than 0.5% and conforming to IS:15622 of approved make in all colours and shades in for outdoor floors such as footpath, court yard, multi modals location etc., laid on 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes and patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge. 0 0 0 HSR 10.107 |
| 258 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead up to 50 m and lift up to 1.5 m, as directed by Engineer-in-charge. 1. All kinds of soil HSR 4.12 |
| 259 | RAIN WATER SPOUTS AND PIPES Providing and fixing on wall face Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 3. 150 mm diameter HSR 9.57 |
| 260 | RAIN WATER SPOUTS AND PIPES Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 5.3. Bend 87.5°150 mm bend HSR 9.58 |
| 261 | M Masonry Chambers Constructing brick masonry inspection Chamber sizes as given below up to 0.60 metre average depth in cement mortar 1:5 lime concrete with 40 per cent lime mortar 2:3 in foundation cement concrete 1:2:4 benching 12mm thick cement plaster 1:2 with a floating coat of 1 mm thick of neat cement R.C.C. 1:2:4 slab 100 mm thick/cement concrete topping, 50mm thick with 455mmx455mm / 455mm x610mm inside light duty C.I. inspection chamber cover and frame weight as per I.S.I. specification painted with 3 coats of black bitumastic superior paint complete as per standard design. 3. Size 600 mm X900 mm inside (with 455 mm x 455 mm cover and frame light duty single seal weighing 20 kg with R.C.C. slab) HSR 21.84 |
| 262 | N MANHOLE CHAMBERS Providing and fixing SFRC MANHOLE COVERS AND FRAMES MARKED WITH IS: 12592 including setting the same to correct lines and levels in 1:3 cement sand mortar over manhole including carriage loading unloading stacking handling re-handling etc. complete in all respects to the satisfaction to the Engineer-in-charge. 1. Type:- Extra Heavy Duty Set (EHD-35) 560MM Clear Opening HSR 21.93 |
| 263 | Providing lowering cutting jointing and testing RCC pipe class NP3 as per IS-458-2003 with spigot and socketed joints manufactured with ISI marked sulphate resistance cement as per ISI 12330 with rubber rings ISI marked antiternmite as required at site in to trenches for all depths and laying out the same to correct alignment gradients and levels including dressing and trimming and cutting of concrete beds and side of trenches, if required jointing with rubber rings in trenches and jointing with 1:3/2 cement sand mortar and with end dowels filled with 1:3/2 cement sand mortar and finishing the joints at an angle of 45 degree with faces of spigot of socket joints cutting and finishing the cut surface to a uniform finish etc. as fully described in item No. 21.38, item 21.44, item 21.45, and item 21.46 including cartage loading and unloading complete in all respects. the internal diametric of the sewer being: 1. 350 mm HSR 21.95 |
| 264 | TUBEWELLS Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire and running charges of all equipments, tools, plants and machineries required for the job, all complete as per direction of Engineer-in-charge, up to 90 metre depth below ground level. 1.3. All types of soil400 mm dia HSR 33.6 |
| 265 | TUBEWELLS Supplying, assembling, lowering and fixing in vertical position in bore well, Unplasticised PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings and accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. 3. 200 mm nominal size dia HSR 33.8 |
| 266 | TUBEWELLS Supplying, filling, spreading and levelling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads and lifts, all complete as per direction of Engineer-in-charge. HSR 33.12 |
| 267 | TUBEWELLS Supplying, filling, spreading and levelling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads and lifts, all complete as per direction of Engineer-in-charge. HSR 33.13 |
| 268 | TUBEWELLS Supplying, filling, spreading and levelling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads and lifts, all complete as per direction of Engineer -in-charge. HSR 33.14 |
| 269 | TUBEWELLS Gravel packing in tube well construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading and sizes as per actual requirement, all complete as per direction of Engineer-in-charge. HSR 33.15 |
| 270 | TUBEWELLS Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for bore well of: 3. 200 mm dia HSR 33.16 |
| 271 | TUBEWELLS Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tube well as per IS: 2800 (part I), including necessary bolts and nuts of required size complete. 3. 200 mm clamp HSR 33.17 |
| 272 | TUBEWELLS Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tube well as per IS:2800 (part I).3. 200 mm dia HSR 33.18 |
| 273 | A CEMENT CONCRETE (CAST IN SITU) Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: 7. 1:5:10 (1 cement : 5 coarse sand (zone-III): 10 graded stone aggregate 40 mm nominal size) HSR 6.1 |
| 274 | D REINFORCED CEMENT CONCRETE Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor four level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). HSR 6.16 |
| 275 | J STEEL REINFORCEMENT Steel reinforcement for R.C.C. work, where not included in the complete rate of RCC, including straightening, cutting, bending, placing in position, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. complete in all respect below plinth level Note: Reinforcement shall be measured in length including hooks, if any, separately for different diameters as actually used in work , excluding overlaps. Wastage, overlaps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods of binding & placing shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement. 6. Thermo-Mechanically Treated bars of grade Fe-500D or more HSR 6.33 |
| 276 | B BRICK WORK Brick work with common burnt clay non-modular bricks of class designation 10.5 in foundation and plinth in: 1. Cement mortar 1:4 (1 cement : 4 coarse sand) HSR 7.21 |
| 277 | CEMENT CONCRETE FLOORING Providing and laying of conglomerate floor 50mm thick cement concrete topping 1:2:4 HSR 10.7 |
| 278 | CEMENT PLASTER (IN FINE SAND) 12 mm cement plaster of mix : 3. 1:4 (1 cement: 4 fine sand) HSR 11.5 |
| 279 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead up to 50 m and lift up to 1.5 m, as directed by Engineer-in-charge. 1. All kinds of soil HSR 4.12 |
| 280 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. HSR 4.32 |
| 281 | CEMENT PLASTER (IN FINE SAND) 10 mm thick cement plaster 2. 1:3 (1 cement: 3 fine sand) HSR 11.4 |
| 282 | CEMENT PLASTER (IN FINE SAND) 12 mm cement plaster of mix : 3. 1:4 (1 cement: 4 fine sand) HSR 11.5 |
| 283 | CEMENT PLASTER (IN FINE SAND) 15 mm cement plaster on the rough side of single or half brick wall of mix : 1. 1:4 (1 cement: 4 fine sand) HSR 11.6 |
| 284 | CEMENT PLASTER WITH A FLOATING COAT OF NEAT CEMENT 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix : 2. 1:4 (1 cement: 4 fine sand) HSR 11.12 |
| 285 | SIGLE/BUILT-UP STEEL/TUBULAR SECTIONS Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. 2. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works HSR 13.29 |
| 286 | WASHED STONE GRIT PLASTER Forming groove of uniform size in the top layer of washed stone grit plaster as per approved pattern using wooden battens, nailed to the under layer, including removal of wooden battens, repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge : 1. 15 mm wide and 15 mm deep groove HSR 11.4 |
| 287 | INTERIOR FINISHING Painting two coats excluding priming coat with synthetic enamel paint in all shades on new wood work or metallic or plastered or concrete surfaces to give an even shade. HSR 11.78 |
| 288 | EXTERIOR FINISHING WALL AND ROOF SURFACES Finishing walls with Acrylic Smooth exterior paint of required shade : 1. New work (Two or more coat applied @ 1.67 litre/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) HSR 11.95 |
| 289 | B BRICK WORK Brick work with common burnt clay non-modular bricks of class designation 10.5 in superstructure above plinth level up to floor IV level in all shapes and sizes in : 1. Cement mortar 1:4 (1 cement : 4 coarse sand) HSR 7.22 |
| 290 | MISCELLANEOUS BRICKWORK ITEMS Dressed or moulded two brick cornice laid in cement sand mortar 1:4 including 12 mm thick cement plaster 1:4 or pointing, as required. HSR 7.57 |
| 291 | MISCELLANEOUS BRICKWORK ITEMS Dressed or moulded one brick cornice laid in cement sand mortar 1:4 including 12 mm thick cement plaster 1:4 or pointing, as required. HSR 7.58 |
| 292 | A CEMENT CONCRETE (CAST IN SITU) Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: 6. 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) HSR 6.1 |
| 293 | B DAMP-PROOF COURSE Providing and laying damp-proof course with cement concrete 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20mm nominal size) 3. 25 mm thick HSR 6.9 |
| 294 | F READY MIX CEMENT CONCRETE WITH FLYASH Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work, including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in-charge. 1. All works up to plinth level HSR 6.24 |
| 295 | F READY MIX CEMENT CONCRETE WITH FLYASH Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work, including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in-charge. 2. All works above plinth level up to floor IV level HSR 6.24 |
| 296 | J STEEL REINFORCEMENT Steel reinforcement for R.C.C. work, where not included in the complete rate of RCC, including straightening, cutting, bending, placing in position, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. complete in all respect above plinth level Note:- Reinforcement shall be measured in length including hooks, if any, separately for different diameters as actually used in work , excluding overlaps. Wastage, overlaps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods of binding & placing shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement. 6. Thermo-Mechanically Treated bars of grade Fe-500D or more. HSR 6.34 |
| 297 | CEMENT CONCRETE FLOORING Extra for using hardener at top surface (3.5Kg /sqm) of trimix M25 to finish surface complete in all respect HSR 10.15 |
| 298 | SIGLE/BUILT-UP STEEL/TUBULAR SECTIONS Supply and Fixing of Tensile Sheet Shed 650GSM sheet with M.S Iron pipe FramePole 125mm Heavy Truss M.S Pipe 60mm Heavy, Membrane M.S Pipe 50mm Heavy, Complete With cost of Painting and Labour for Fixing Paint Complete in all respects HSR 13.34 |
| 299 | Clearing and Grubbing Road Land . Compacting Original Ground 3. Compaction of EarthworkCompaction of & preparation of sub grade including loosening, levelling of earth 225 mm thick top layer, rough dressing of soil, final dressing of earth to give level, camber, watering, rolling with road roller, compacting the bed to achieve minimum dry density as given in the Table 3000-2 as per technical clause 305 of MORT&H specifications HSR 17.5 |
| 300 | Clearing and Grubbing Road Land . Granular Sub-Base (Mix in place) Construction of granular sub-base by providing Material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with Rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per technical clause 401 of MORT&H technical specifications HSR 17.13 |
| 301 | Unreinforced Vaccum Concrete Pavement Construction of unreinforced plain cement concrete pavement in M-30 mix design over a prepared sub base with OPC 43 grade conforming to IS:383 mixed with concrete mixer using batch type concrete mixer as per IS:1791, laid in position, compacted with needle vibrator, screed vibrator and plate vibrator, dewatering of free water with vaccum pump, finishing the surface with power floater, finishing to required lines and grades as per drawings and technical clause 1501 of MORTH specifications HSR 17.72 |
| 302 | E READY MIX CEMENT CONCRETE Providing and laying in position ready mixed plain cement concrete, with cement content as per approved design mix and manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for plain cement concrete work, including pumping of R.M.C. from transit mixer to site of laying and curing, excluding the cost of centering, shuttering and finishing, including cost of curing, admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in-charge. 2.3. All works up to Plinth Level :M-10 grade plain cement concrete (cement content considered @ 220 kg/cum) HSR 6.22 |
| 303 | Cast in Situ Cement Concrete M20 KerbConstruction of cement concrete kerb with top and bottom width 115 and 165 mm respectively, 250 mm high in M 20 grade PCC on M-10 grade foundation 150 mm thick, foundation having 50 mm projection beyond kerb stone, kerb stone laid with kerb laying machine, foundation concrete laid manually, all complete as per clause 408 1. Using Concrete Mixer HSR 34.1 |
| 304 | SUPER STRUCTURE Filler joint 4. Providing and filling joint sealing compound as per drawings and MoRT&H specifications with coarse sand 6 per cent bitumen by weight - 10 mm depth HSR 27.51 |
| 305 | B0401. Cutting groove in RCC (75mmx10mm) HSR 2 |
| 306 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 1. All kinds of soil. HSR 4.14 |
| 307 | RAIN WATER SPOUTS AND PIPES Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 5.3. Bend 87.5°150 mm bend HSR 9.58 |
| 308 | Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. 1. All kinds of soil HSR 4.31 |
| 309 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. HSR 4.32 |
| 310 | C FIXING INCLUDING CARRIAGE Providing and fixing steel bar embedded plastic steps of size 263mm x 165mm of orange colour, confirming to specification in pump chambers, manholes etc., having minimum 3mm thick polypropylene polymer confirming to is:10910 encapsulated on 12mm dia ribbed steel bars per IS :1786. The rate include cost of setting the same to correct lines and levels duly embedded in 1:2:4 cement concrete including carriage, loading, uploading, stacking, handling, re-handling etc., complete in all respect to the satisfaction of Engineer-in-charge HSR 21.28 |
| 311 | STEEL DOOR/ WINDOW FRAMES AND SHUTTERS Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 2.0 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 2.00 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge: 1.1. Profile B Fixing with adjustable lugs with split end tail to each jamb HSR 13.3 |
| 312 | STEEL DOOR/ WINDOW FRAMES AND SHUTTERS Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 2.0 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 2.00 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge: 3.1. Profile E Fixing with adjustable lugs with split end tail to each jamb HSR 13.3 |
| 313 | TILE FLOORING Providing and laying of chequered terrazzo tiles 20 to 22 mm thick with graded marble chips of size up to 6 mm in floors, jointed with neat cement slurry mixed with pigment to match the shade of the tiles, including rubbing and polishing complete, on 20 mm thick bed of cement mortar 1:4 (1 cement :4 coarse sand) : 2. Medium shade pigment using 50% white cement, 50% ordinary cement HSR 10.29 |
| 314 | CEMENT PLASTER WITH A FLOATING COAT OF NEAT CEMENT 12 mm cement plaster finished with a floating coat of neat cement of mix : 2. 1:4 (1 cement: 4 fine sand) HSR 11.11 |
| 315 | CEMENT PLASTER WITH A FLOATING COAT OF NEAT CEMENT 6 mm plaster on cement concrete or reinforced cement concrete work with white cement based polymer modified self curing mortar of approved make as per the direction of Engineer-In-Charge. HSR 11.15 |
| 316 | STEEL DOOR/ WINDOW FRAMES AND SHUTTERS Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. 1. Using M.S. angels 40x40x6 mm for diagonal braces HSR 13.6 |
| 317 | KOTA STONE FLOORING Providing and fixing of Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 1. 25 mm thick HSR 10.37 |
| 318 | KOTA STONE FLOORING Providing and fixing of Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. HSR 10.38 |
| 319 | PRE-PAINTED / POWDER COATED GALVANISED SHEET DOOR/WINDOW FRAMES AND WINDOW SHUTTERS Supply and fixingWindows frames (Chowkhats) including mullions consisting frame fabricated from sheet roll formed out of 0.58mm thick galvanized sheet (Base steel as per IS 513) with zinc of 120 gm/sqm steel sheet pre coated (as per approved colour) with Polyester paint of 12-16 microns thickness under coat of EPOXY primer and back coat with ALKYD backer of 5-7 microns, total sheet thickness with coating 0.58mm of approved shade, weld less corner assembly with brackets and screws, fixed in position by means of PVC and metal hold fastener with PVC cap complete in all respects as per drawing, design, specification and entire satisfaction of Engineer-in-charge 1. Glazed Windows shutter section 47mm x 20mm (Without Glass) HSR 13.23 |
| 320 | PRE-PAINTED / POWDER COATED GALVANISED SHEET DOOR/WINDOW FRAMES AND WINDOW SHUTTERS Supply and fixingWindows frames (Chowkhats) including mullions consisting frame fabricated from sheet roll formed out of 0.58mm thick galvanized sheet (Base steel as per IS 513) with zinc of 120 gm/sqm steel sheet pre coated (as per approved colour) with Polyester paint of 12-16 microns thickness under coat of EPOXY primer and back coat with ALKYD backer of 5-7 microns, total sheet thickness with coating 0.58mm of approved shade, weld less corner assembly with brackets and screws, fixed in position by means of PVC and metal hold fastener with PVC cap complete in all respects as per drawing, design, specification and entire satisfaction of Engineer-in-charge 3. Providing & fixing fixed beading 12mm x 12mm for fixed glass ECO fixed gasket (EPDM) HSR 13.23 |
| 321 | CERAMIC GLAZED TILES Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete. HSR 10.57 |
| 322 | CERAMIC GLAZED TILES Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. HSR 10.58 |
| 323 | PRE-PAINTED / POWDER COATED GALVANISED SHEET DOOR/WINDOW FRAMES AND WINDOW SHUTTERS Providing and fixingglazing in door, window, ventilator shutters and partitions etc. complete as per the architectural drawings and the directions of engineer-in-charge. (Cost of Gasket / beading shall be paid as per respective item) 1. Float glass panes of 5.5mm thickness HSR 13.24 |
| 324 | SIGLE/BUILT-UP STEEL/TUBULAR SECTIONS Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. 2. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works HSR 13.29 |
| 325 | STAINLESS STEEL RAILING Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories and stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). HSR 13.41 |
| 326 | INTERIOR FINISHING Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. HSR 11.6 |
| 327 | INTERIOR FINISHING Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer`s specification. 1. Two or more coats on new work HSR 11.65 |
| 328 | INTERIOR FINISHING Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. 2. Two coats HSR 11.75 |
| 329 | INTERIOR FINISHING Painting two coats excluding priming coat with synthetic enamel paint in all shades on new wood work or metallic or plastered or concrete surfaces to give an even shade. HSR 11.78 |
| 330 | EXTERIOR FINISHING WALL AND ROOF SURFACES Finishing walls with Acrylic Smooth exterior paint of required shade : 1. New work (Two or more coat applied @ 1.67 litre/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) HSR 11.95 |
| 331 | WATERPROOFING TREATMENT TO RETAINING WALL AREA FROM EXTERNAL SIDE USING LIQUID APPLIED SINGLE COMPONENTPITCH FREE POLYURETHANE COATING Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservoir, sewage and water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fibre brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e. by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage. 1. For vertical surface two coats @ 0.70 kg per sqm HSR 28.2 |
| 332 | WATERPROOFING TREATMENT TO RETAINING WALL AREA FROM EXTERNAL SIDE USING LIQUID APPLIED SINGLE COMPONENTPITCH FREE POLYURETHANE COATING Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservoir, sewage and water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fibre brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e. by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage. 2. For horizontal surface one coat @1.10 kg per sqm HSR 28.2 |
| 333 | B BRICK WORK Brick work with common burnt clay non-modular bricks of class designation 10.5 in superstructure above plinth level up to floor IV level in all shapes and sizes in : 1. Cement mortar 1:4 (1 cement : 4 coarse sand) HSR 7.22 |
| 334 | GI PIPES Providing and fixing G.I. pipes complete with G.I. fittings including trenching up to 0.30m to 1.00m depth and refilling etc. External work 6. 50 mm dia nominal bore HSR 22.91 |
| 335 | N MANHOLE CHAMBERS Providing and fixing SFRC MANHOLE COVERS AND FRAMES MARKED WITH IS: 12592 including setting the same to correct lines and levels in 1:3 cement sand mortar over manhole including carriage loading unloading stacking handling re-handling etc. complete in all respects to the satisfaction to the Engineer-in-charge. 1. Type:- Extra Heavy Duty Set (EHD-35) 560MM Clear Opening HSR 21.93 |
| 336 | HDPE pipes for Drainage Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 ofE.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. 2.1. Single Socket Type B 160mm o/d SWR UPVC pipe lines laid complete HSR 22.222 |
| 337 | A CEMENT CONCRETE (CAST IN SITU) Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: 6. 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) HSR 6.1 |
| 338 | C PLINTH PROTECTION Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling and dressing and finishing the top smooth. HSR 6.13 |
| 339 | F READY MIX CEMENT CONCRETE WITH FLYASH Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work, including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in-charge. 1. All works up to plinth level HSR 6.24 |
| 340 | I CENTRING AND SHUTTERING (FORM WORK) Centering and shuttering including strutting, propping etc. and removal of form for 1. Foundations, footings, bases of columns, etc. for mass concrete HSR 6.3 |
| 341 | I CENTRING AND SHUTTERING (FORM WORK) Centering and shuttering including strutting, propping etc. and removal of form for 2. Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc. HSR 6.3 |
| 342 | I CENTRING AND SHUTTERING (FORM WORK) Centering and shuttering including strutting, propping etc. and removal of form for 3. Suspended floors, roofs, landings, balconies and access platform HSR 6.3 |
| 343 | I CENTRING AND SHUTTERING (FORM WORK) Centering and shuttering including strutting, propping etc. and removal of form for 5. Lintels, beams, plinth beams, girders, bressumers and cantilevers HSR 6.3 |
| 344 | I CENTRING AND SHUTTERING (FORM WORK) Centering and shuttering including strutting, propping etc. and removal of form for 7. Stairs, (excluding landings) except spiral-staircases HSR 6.3 |
| 345 | I CENTRING AND SHUTTERING (FORM WORK) Centering and shuttering including strutting, propping etc. and removal of form for 19. Weather shade, Chajjas, corbels etc., including edges HSR 6.3 |
| 346 | Supplying, erection, testing and commissioning of submersible motor pumping set non clog for sewerage having head 30.00 m as per the indicated requirements of discharge in LPM and power capacity in BHP as per IS marked including all accessories (like SS Pipes, SS Chain (Shackle Chain) ,SS Foundation Bolt, complete base frame, Monorail, Chain Guide Line, Auto Compiling, Duct Foot Bend (D/F Bend) etc. complete in allrespect 10. Discharge Capacity (LPM) - 500 Power Capacity (BHP) - 5 HSR 21.11 |
| 347 | J STEEL REINFORCEMENT Steel reinforcement for R.C.C. work, where not included in the complete rate of RCC, including straightening, cutting, bending, placing in position, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. complete in all respect above plinth level Note:- Reinforcement shall be measured in length including hooks, if any, separately for different diameters as actually used in work , excluding overlaps. Wastage, overlaps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods of binding & placing shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement. 6. Thermo-Mechanically Treated bars of grade Fe-500D or more. HSR 6.34 |
| 348 | Supply and Fixing dormakaba 9117711 or equivalent Surface Mounted Tower bolt of Length 18` in SS finish with fixing accessories as per direction of engineer-in-charge. |
| 349 | Supply and Fixing dormakaba 9117713 or equivalent Surface Mounted Tower bolt of Length 12` in SS finish with fixing accessories as per direction of engineer-in-charge. |
| 350 | Providing and fixing Dormakaba SR-390 or Equivalent Surface mounted door coordinator for double doors , zinc plated for steel doors, non-Handed as per EN1158 and CE marked as per direction of Engineer-in Charge.Fire Rated 2hrs. |
| 351 | Providing and fixing dormakaba Mortice dead lock 288a or equivalent with 55mm backset, 20mm square forend and prepared for euro profile cylinder including strike plate in satin stainless steel as per EN 12209, CE marked. Complete with EPC 70mm Length both side key operation and Escutcheons in SSS Finish.as per direction of Engineer-in-Charge.Fire Rated - 2 Hours. |
| 352 | Supply and installation of 100% commercial grade nylon carpet tile of 500x500mm of solution dyed nylon 6 ( AquafilEconyl) quality or equivalent, manufactured in Japan, Machine Gauge 1/10” or more and having backing of glass fiber plus PVC and made of basic fabric of Nonwoven Polyester , total height of 7 mm or more, Pile height H4mm / L 2mm /H 5mm / L 2.5mm smoke density ( ASTM E 662) less than 450, anti static less than 1.0kv (JIS-L4406 STROLL 23 C. degree 25%R.H.), electrostatic propensity – maximum average 0.5kv (AATCC 134) Color fastness to light- rating 5.0= No change (AATCC 16) critical radiant flux –( ASTM E 648) Class 1 average CRF 0.48 / cm2 or higher certified. Certificate of Japanese industrial standard (JIS) Mark. Range 4000 series, Make Japan Carpet as per selection and approval. |
| 353 | Providing and fixing Sparkle frosted filming on Glass panes complete in all respect. |
| 354 | Providing and fixing of glass patch lock with cylinder complete in all respect. Make Dorset, Model -DPF-325 |
| 355 | Providing and fixing pull Handle back to back with 350mm CTC, adjustable fixing for glass, wood, and metal doors in satin stainless steel with supporting washer with raised bevelling on the outer surface of Length =450mm, 25mm dia, -SS304 as per the direction of the Engineer in charge. (Make - Dormakaba, Geje, Dorset) |
| 356 | Providing and fixing Fire Rated door having double/single leaf 46 mm thick made out of 1.2 mm thick powder coated galvanised steel sheet of approved color having 120 mins fire rating conforming to IS : 3614 (Part 2) or EN1634- 1-1999, tested and certified as per approved laboratory with door frame of GI having single ribbed grooved profile of section 100X55 mm made out of 1.60 mm thick galvanised steel sheet with a factory pre punched groove so as to accommodate fire and smoke seal of size 10X4 mm with zinc coating not less than 120gm/m2. The doors shutter should be duly filled rock wool insulation complete in all respects to the satisfaction of enginner incharge.(The Cost of smoke/fire seal , vision panel, hardware are excluded.) |
| 357 | Door Closer : Providing and fixing fire rated rack and pinion door closer of make Dorma TS 71 EN size 3/4, with std. arm and with two independent closing valves and latching speed adjustable by arm. Full plastic cover. Silver finish. As per EN 1154. The door closer shall have a 10 year mechanical guarranty / warranty from the manufacturer and the same shall be submitted to the Engineer-in-charge. |
| 358 | Providing and fixing dormakaba pull Handle TGDI-D 300 back to back with adjustable fixing for glass, wood and metal doors in satin stainless steel. The pull handles should have supporting washer with raised bevelling on the outer surface. Length =300mm, 22mm dia, -SS304as per the direction of Engineer in charge. |
| 359 | Providing and Fixing Hilti Anchor faster Hilti-V (5.8) M-16 Ø or equivalent, 150/180 mm Long with RE 500 V4 (adhesive). |
| 360 | Providing and Erecting of (S.S.304) Stainless Steel structural steel work as per the design approved, complete in all respects. |
| 361 | Providing and fixing high-density polyethylene (HDPE) with 8mm dimples board used as a protection board for waterproofing to be fixed vertically on external side of retaining wall. The board should be high strength one sidedimpled structure, light in weight yet flexible strong and resilient. Rate is inclusive of material, wastage, labour andoverlab to the board. Actual area of the retaining wall will be measured for payment.(Make- Tikidan, Greentek plast or Equivalent) |
| 362 | Providing and fixing SS 304 Ball Bearing hinges 4`x3` for fire rated door complete as per direction of engineer in charge |
| 363 | Recovery of excess quantity of sand/gravel/all kind of soils of various sizes received after excavation of the basement and other building portion including loading, unloading vertical heads, horizontal head, stacking, lead and transportation and any lead including royalty and all clearance statuary permission will be obtained by the contractor / Agency from mining or other department. The total expenditure on this account will be totally borne by the contractor/ agency complete in all respect. (Note: Excess quantity of excavated soil is to be shifted by the agency and complete required quantity of earth are to be kept at site by the agency. It is also made clear that if the excess quantity of excavation / soil lifted by the agency and it is required at site the contractor/ Agency will supply the quantity of excavated material / soil free of cost at any time. ) |
| 364 | Providing and fixing glazing with toughened glass panes of 12 mm thickness in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): |
| 365 | Providing and fixing of 12mm thick clear toughened glass (Fix Glass) for fixing with wall, including necessary fittings, patch fittings ( SS 304) of frameless glass partition as per drawing and directions of Engineer in charge of the work |
| 366 | Providing and fixing UPVC floor trap 2`` (Supreme) make in position complete in all respect as per the direction of engineer of incharge |
| 367 | Providing and fixing Hand Shower (Health Faucet) With 8mm Dia make Description No. 39221000 (Cat. No. ALD-CH R-573) complete in all respect. |
| 368 | Providing and fixing Exposed Part Kit Of Concealed Stop Cock make Description No. 84818020 (Cat. No. COP-CH R-083NK PM) complete in all respect. |
| 369 | Providing and fixing Bottle Trap (With Internal Partition) 32 make Description No. - 74182010(Cat. No. ALD-CH R-769L3 00X190) in all respect. |
| 370 | Providing and fixing vanity with vitreous china ware counter top wash basin of size 600mm x 450mm, vanity made up of PVC board of thickness 20mm with openable shutters/ drawers, and legs of vanity made of fiber, finished with DECO paint as per. approved design, including necessary hardware, complete in all respects or as per the entire satisfaction of the Engineer in charge.(Note:- All the CP sanatary fittings and waste pipe should be paid separately) |
| 371 | Providing and fixing SS 304 Grab Bar Vertical Swing with dimensions of 738 mm X 300 X 100 mm and 32 mm dia of Jaquar make (Cat. No. WAC-SAP-BG0800CSN) complete in all respects. |
| 372 | Providing and fixing SS 304 Grab Bar 600mm Long, 32 mm dia of Jaquar make (Cat. No. WAC-SAP-BR0600CSN) complete in all respects. |
| 373 | Providing and fixing CP BrassTowel Ring Square make Description No. - 83025000 (Cat. No.ACN-CH R-1121N) in all respect. (Make -Jaquar or equivalent) |
| 374 | Providing and fixing CP Brass Soap Dispenser With Metallic Bottle make Description No. - 96161020 (Cat. No.ACN-CH R-1137N) in all respect. (Make -Jaquar or equivalent) |
| 375 | Providing and fixing CP Brass Waste Coupling 32mm Size WIT make Description No. -74182010 (Cat. No.ALD-CH R-709) complete in all respect. (Make -Jaquar or equivalent ) |
| 376 | Providing and fixing CP Brass Toilet Roll holder with stainless steel 304 grade flap Description No. 74182010 (Cat. No. CAN-CHR-1153S) complete in all respect. (Make jaquar or equivalent) |
| 377 | Providing and fixing upvc vent cowl complete in all respects to the satisfaction of the engineer-in-charge (brand as approved make of list). 160 mm dia |
| 378 | Providing and fixing upvc vent cowl complete in all respect to the satisfaction of engineer-in-charge (brand as approved make of list). 110 mm dia |
| 379 | Providing and fixing in position SS 304 Jali of heavy quality 100mm dia of standard make approved be engineer in charge complete to the entire satisfaction of Engineer in charge |
| 380 | Providing and fixing acrylic multilingual Braille (raised dots) signboards (DOOR SIGN BOARDS) of size 6`x 9` /12” x5”for room titles, designed as per the drawings issued and having 3mm thick blue acrylic base plate with Upper Case San Serif words made of white acrylic non glare cut out letters of height 15mm raised not less than 0.8mm above base plate and the equivalent word/s written in Hindi with Devanagari non glare acrylic letters of height 15mm raised not less than 0.8mm above base plate. Grade 2/ Grade 1 Braille to be integral with the sign face and be raised 0.5mm above base plate. Each signboard to be fixed as per manufacturers specifications on the wall adjoining the respective room door at a height of 1200mm from FFL complete as per design / specifications and guidelines as per the entire satisfaction of the Engineer-in-charge (NS) |
| 381 | Providing and fixing of acrylic, non-glare, tactile audio pictorial building layout as per the approved size, design and make, having 6mm thick acrylic non glare base plate of the approved color and non-glare acrylic cut out symbols and upper case Sans Serif letters of 12mm height, raised 3mm above base plate and Grade 2/ Grade 1 Braille to be integral with the sign face and be raised 0.5mm above base plate. The map to be installed at the specified location as per accessibility standards, shall be oriented to the position of the viewer and to be installed at a height of 800 mm from the finished ground/ floor level and using the necessary hardware specified by the manufacturer and to be installed up to the height of 800 mm from the finished ground/ floor level and using the necessary hardware specified by the manufacturer and to be installed complete as per design/specificaitons and guidelines as per the entire satisfaction of the the Engineer-in-charge |
| 382 | Providing and fixing acrylic Braille indicators for handrails of the approved design and make having Braille dots raised 0.5mm above base plate, to be installed at the specified locations as per the directions of the engineer in charge complete as per design/specificaitons and guidelines as per the entire satisfaction of the the Engineer-in-charge |
| 383 | Providing and fixing acrylic Braille indicators for handrails of the approved design and make having Braille dots raised 0.5mm above base plate, to be installed at the specified locations as per the directions of the engineer in charge complete as per design/specifications and guidelines as per the entire satisfaction of the the Engineer-in-charge. |
| 384 | Providing and fiixing acrylic multilingual Braille (raised dots) DIRECTIONAL SIGNBOARDS of size 6` x 9` designed as per accessibility standards and having 4mm thick acrylic base plate with Upper Case San Serif words made of white acrylic non glare cut out letters of height 15mm raised not less than 0.8mm above base plate and the equivalent word written in Hindi with Devanagari non glare acrylic letters of height 15mm raised not less than 0.8mm above base plate and having a non-glare acrylic cut arrow pointing in the required direction. Each signboard to be fixed as per manufacturers specifications on the wall at the approved location and at a height of 1200mm from FFL complete as per design/specifications and guidelines as per the entire satisfaction of the Engineer-in-charge |
| 385 | Providing and Fixing of Pictorial layout plan of size 900mmx600mm as approved design, made of 3mm thick acrylic non glare base plate and non glare cut out symbols with grade One Braille on which individual facility points, like inquiry, reception, restrooms, medical room/ first aid, cafeteria or breakout area, lounge, meeting room, conference room etc. present the respective floors with pictograph wherever needed all in tactile raised by minimum of 1to2 mm in various colours to make it legible for seniors, partial vision impaired etc. All the facility names should be in Braille, along with English or Hindi. The entire block of tactile signs should be mounted on wall or on a slant/ inclined frame for easy reading. The map to be installed at specified locations and installed at a height of 800mm from ground level complete in all respect as per Harmonized guideline and satisfaction of Engineer-in-charges |
| 386 | Providing and fixing of high intensity reflective PVC conspicuity tape 25 to 50mm width, on edges of treads in staircase including, cutting, pasting etc. of make 3M or equivalent brand complete in all respect to the entire satisfaction of Engineer-in-charge |
| 387 | Providing and fixing 50mm wide colour contrast Rubber `EDGE STRIPS` self-adhesive on treads of staircases to help people with visual disabilities and the elderly, even in dim light conditions, complete in all respects to the entire satisfaction of the Engineer-in-charge |
| 388 | Providing and fixing Multilingual and tactile Emergency evacuation map (of sturdy plastic) of each floor indicating the current position of the viewer saying `YOU ARE HERE` of 15mm height letters in red with white background, indicating the emergency exits, locations of fire extinguishers etc. Signs shall have a solid header with the text “EVACUATION PLAN” in contrasting uppercase letters no less than 3/4` in height. The size of the board shall be 2ft x 2ft and shall be installed at a height of 1200mm from FFL and shall be oriented to the position of the viewer as per the direction of the site engineer complete as per design/specificaitons and guidelines as per the entire satisfaction of the the Engineer-in-charge |
| 389 | Providing and fixing of SS 304, non-glare multilingual Braille (raised dots) ENTRANCE SIGNAGE (size 1 ft x 1 ft) as per the approved design and make, indicatingthe name of the building having 1.2mm thick SS non glare blue colored base plate with the `Universal Accessibility Symbol` and Upper case Sans Serif words of height15mm engraved on it along with the equivalent word/ s written in Hindi using Devanagari script of height 15mm in white color Grade 2/ Grade 1 Braille to be etched/engraved and be raised 0.5mm above base plate. The signage to be installed at the specified location on the compound wall near the site entrance gate installed at aheight of 1200 mm from the finished ground/ floor level, using the necessary hardware specified by the manufacturer and to be installed complete as perdesign/specifications and guidelines as per the entire satisfaction of the Engineer-in-charge |
| 390 | Providing and fixing retro-reflective information SIGNAGES to provide clear information about the the building/institute in English/Hindi languages clearly visible, readable, understandable , with Type XI Retro Reflective Sheeting (of make 3M or equivalent) as per ASTM D4956 standard and appropriate level, made of 3mm thick ACP sheet with border of 50mm dia round pipe and supported with 200mm dia round pipers of 10-gauge fixed in the gate pillars properly designed M-20 grade cement concrete complete in all respect as per design/specifications and guidelines as per the entire satisfaction of the Engineer-in-charge (Size 6 Mtr. X 1.22 Mtr.) |
| 391 | Providing and fixing of SS 304, non-glare Signage board (2 ft. x 2 ft.- 1 no.) for the accessible parking, as per the approved design and make, having 1.2mm thick SS non glare base plate and Grade 2/Grade 1 Braille (raised dots)to be etched/engraved and be raised 0.5mm above base plate and Upper Case San Serif words and Universal Accessibility Symbol to be etched/engraved and signage to be installed at a height of 2100mm from the ground level using a post of MS hollow square section (50mm x 50mm with minimum thickness of 2mm) as per the installation procedure specified by the manufacturer and as per accessibility standards complete as per design/specifications and guidelines as per the entire satisfaction of the Engineer-in-charge |
| 392 | COPPER WIRING IN PVC CONDUIT (SURFACE/RECESS) 6.1. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in PVC Conduit etc as required. 1 run of Size 1.50 Sqmm(1/1.40mm). (HSR . 23.3.6.1.) |
| 393 | COPPER WIRING IN PVC CONDUIT (SURFACE/RECESS) 6.3. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in PVC Conduit etc as required. 1 run of Size 4 Sqmm(1/2.24mm) (HSR . 23.3.6.3.) |
| 394 | COPPER WIRING IN PVC CONDUIT (SURFACE/RECESS) 6.4. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in PVC Conduit etc as required. 1 run of Size 6 Sqmm(1/2.80mm) (HSR . 23.3.6.4.) |
| 395 | COPPER WIRING IN PVC CONDUIT (SURFACE/RECESS) 6.5. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in PVC Conduit etc as required. 1 run of Size 10 Sqmm(1/3.50 mm) (HSR . 23.3.6.5.) |
| 396 | COPPER WIRING IN PVC CONDUIT (SURFACE/RECESS) 6.6. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in PVC Conduit etc as required. 2 run of Size 1.50 Sqmm(1/1.40mm). (HSR . 23.3.6.6.) |
| 397 | COPPER WIRING IN PVC CONDUIT (SURFACE/RECESS) 6.8. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in PVC Conduit etc as required. 2 run of Size 4 Sqmm(1/2.24mm) (HSR . 23.3.6.8.) |
| 398 | COPPER WIRING WITH MODULAR SWITCHES IN PVC CONDUIT (SURFACE/RECESS) 1.2. Wiring for Light/Fan/call bell point with modular type switch/socket and GI box, Modular type face plate etc in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick PVC conduit pipe. Group B. (HSR 23.4.1.2.) |
| 399 | COPPER WIRING WITH MODULAR SWITCHES IN PVC CONDUIT (SURFACE/RECESS) 2.2. Wiring for Twin control light point with 2 nos, 2-ways, 5 amp. Modular switch GI box and modular face plate in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick PVC conduit pipe. Group B (HSR 23.4.2.2.) |
| 400 | COPPER WIRING WITH MODULAR SWITCHES IN PVC CONDUIT (SURFACE/RECESS) 3.2. Wiring for Light/Fan/call bell point in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick PVC conduit pipe, without separate control switch Group B (HSR 23.4.3.2.) |
| 401 | COPPER WIRING WITH MODULAR SWITCHES IN PVC CONDUIT (SURFACE/RECESS) 4.2. Wiring in PVC conduit system for 3-pin5amp. Plug point by using 2 no 1.5 sqmm FRLS copper wire and 1 no 1.5 Sqmm FRLS copper wire , including providing 1 no 5/6 Amp 3/5 pin Modular type socket and 1 no 5/6 Amp Modular type switch required GI Box ,modular face plate etc complete as required Group B (HSR 23.4.4.2.) |
| 402 | COPPER WIRING WITH MODULAR SWITCHES IN PVC CONDUIT (SURFACE/RECESS) 5.2. Wiring in PVC conduit system for 3-pin15amp. Plug point by using 2 no 4 sqmm FRLS copper wire and 1 no 4 Sqmm FRLS copper wire for earthling , including providing 1 no 15/16 Amp 3/6 pin Modular socket and 1 no 15/16 Amp Modular switch required GI Box , modular face plate etc complete as required Group B (HSR 23.4.5.2.) |
| 403 | EARTHING AND LIGHTENING ARRESTOR 1. Earthing with GL earth pipe 4.5 m long and 40 mm dia with masonry enclosures on the top etc. (but without charcoal or coke and salt) as required. (HSR 24.1.1) |
| 404 | EARTHING AND LIGHTENING ARRESTOR 2. Extra for using salt and char coal/coke for pipe earth electrode as required. (HSR 24.1.2) |
| 405 | EARTHING AND LIGHTENING ARRESTOR 3. Earthing with G.I. earth plate 600 mmx 600 mm x 6 mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt) complete as required. (HSR 24.1.3) |
| 406 | EARTHING AND LIGHTENING ARRESTOR 4. Earthing with tinned copper earth plate 600mmx600mmx3mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt) etc. complete as required. (HSR 24.1.4) |
| 407 | EARTHING AND LIGHTENING ARRESTOR 5. Extra for charcoal or coke and salt for G.I. plate or copper plate earth electrode. (HSR 24.1.5) |
| 408 | EARTHING AND LIGHTENING ARRESTOR 6. Supplying and laying 25mm x 3mm G.I. strip at 0.5 metre below ground as strip earth electrode including soldering etc. as required. (HSR 24.1.6) |
| 409 | EARTHING AND LIGHTENING ARRESTOR 7. Supplying and laying 25mm x 3 mm G.I. strip in 40 mm dia,GI pipe as/from earth electrode including soldering etc. as required. (HSR 24.1.7) |
| 410 | EARTHING AND LIGHTENING ARRESTOR 8. Providing and fixing 25 mm x 3mm G.I. strip on surface or in recess for connections etc. as required with all labour and material. (HSR 24.1.8) |
| 411 | EARTHING AND LIGHTENING ARRESTOR 9. Providing and fixing 25 mm x5 mm copper strip in 40 mm dia G.I. pipe from earth electrode as required. (HSR 24.1.9) |
| 412 | EARTHING AND LIGHTENING ARRESTOR 10. Providing and fixing 25 mm x 5mm copper strip on surface or in recess for connections etc. as required with all labour and material. (HSR 24.1.10) |
| 413 | EARTHING AND LIGHTENING ARRESTOR 11. Providing and laying earth connections from earth electrode with 4.00 mm dia G.I. wire in 15 mm dia G.I. pipe from earth electrode as required. (HSR 24.1.11) |
| 414 | EARTHING AND LIGHTENING ARRESTOR 13. Providing and fixing 4.00 mm dia G1. Wire on surface or in recess for loop earthing as required. (HSR 24.1.13) |
| 415 | EARTHING AND LIGHTENING ARRESTOR 14. Supply and erection of 20mm x 3 mm thick GI, tape fixed with suitable G.I. staples of same size. (HSR 24.1.14) |
| 416 | EARTHING AND LIGHTENING ARRESTOR 16. Supply and erection of 25mm dia 1.5 metre long lightning GI. tube rod tapered into a point at the top with 16cm x 16cm x 3mm thick G.I. base plate and necessary nuts and bolts with washers. (HSR 24.1.16) |
| 417 | EARTHING AND LIGHTENING ARRESTOR 17. Providing and fixing testing joints made of 20mm x 3mm thick G.I. strips 125 mm long with 4 nos. G.I. bolts and nuts with washers complete. (HSR 24.1.17) |
| 418 | LT CABLE 6.1. Supply and erection of copper lugs including crimping etc. entire satisfaction of Engineer-in- Charge of the work 1.5 sqmm. (HSR 24.2.6.1) |
| 419 | LT CABLE 6.3. Supply and erection of copper lugs including crimping etc. entire satisfaction of Engineer-in- Charge of the work. 4 sqmm (HSR 24.2.6.3) |
| 420 | LT CABLE 6.4. Supply and erection of copper lugs including crimping etc. entire satisfaction of Engineer-in- Charge of the work. 6 sqmm (HSR 24.2.6.4) |
| 421 | LT CABLE 6.5. Supply and erection of copper lugs including crimping etc. entire satisfaction of Engineer-in- Charge of the work. 10 sqmm (HSR 24.2.6.5) |
| 422 | LT CABLE 7.1. Supply and erection of suitable compression type brass cable glands for underground Cable :- Up to 6 Sq mm cable 2 to 4 Core (HSR 24.2.7.1) |
| 423 | LT CABLE 7.2. Supply and erection of suitable compression type brass cable glands for underground Cable :- 10 sqmm to 16 sqmm Cable 2 to 4 Core (HSR 24.2.7.2) |
| 424 | LT CABLE 7.3. Supply and erection of suitable compression type brass cable glands for underground Cable :- 25 sqmm to 50 sqmm Cable 2 to 4 Core (HSR 24.2.7.3) |
| 425 | LT CABLE 7.5. Supply and erection of suitable compression type brass cable glands for underground Cable :- 120 sqmm to 185 sqmm Cable 3 to 32 Core (HSR 24.2.7.5) |
| 426 | LT CABLE 7.7. Supply and erection of suitable compression type brass cable glands for underground Cable :- 300 sqmm to 400 sqmmCable 3 to 3½ Core (HSR 24.2.7.7) |
| 427 | LT CABLE 8.2. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in- charge of the work. 4 sqmm to 6 sqmm (HSR 24.2.8.2) |
| 428 | LT CABLE 8.3. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in- charge of the work. 10 sqmm (HSR 24.2.8.3) |
| 429 | LT CABLE 8.4. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in- charge of the work. 16 sqmm (HSR 24.2.8.4) |
| 430 | LT CABLE 8.6. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in- charge of the work. 35 sqmm (HSR 24.2.8.6) |
| 431 | LT CABLE 8.7. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in- charge of the work. 50 sqmm (HSR 24.2.8.7) |
| 432 | LT CABLE 8.12. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in- charge of the work. 185 sqmm (HSR 24.2.8.12) |
| 433 | LT CABLE 8.14. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in- charge of the work.300 sqmm (HSR 24.2.8.14) |
| 434 | COPPER WIRING IN EXISTING PVC/MS CONDUIT PIPE SURFACE/RECESSED FOR ELECTRICAL POINTS 6.8. Wiring main and submains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in existing MS/PVC Conduit etc as required. 2 run of Size 4 Sqmm(1/2.24mm) (HSR 23.5.6.8) |
| 435 | HT CABLE 3.1. Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :70 to 120 sqmm (HSR 23.3.3.1) |
| 436 | HT CABLE 4.1. Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :70 to 120 sqmm (HSR 23.3.4.1) |
| 437 | STREET LIGHT 8.1. Supply and erection of Hot Dip Galvanized octagonal pole of 3mm thickness, with base plate including cost of nut and bolts , earthing studs, Integral Cable termination arrangement 5 mm thick Bakelite base plate on suitable welded MS/GI bracket 32 A four way connector 2 no 10 A SP MCB , end cover and all accessories as supplied by the manufacture including Providing RCC foundation of M25 grade (1 Cement:1 Stone aggregate: 2 Coarse sand) i/c excavation, steel reinforcement (Fe 500) @80 kg/cum of concrete contents, concrete cover 50mm, anchor bolts etc. over a bed of PCC 1:5:10 of required dimensions for octagonal poles of various heights as per following specifications complete in all respects and as per directions of Engineer-in-charge3 Metre Long pole with top dia 65 mm and bottom dia 130mm with base plate of size 200 x 200 x 12 mm (HSR 24.4.8.1) |
| 438 | STREET LIGHT 8.4. Supply and erection of Hot Dip Galvanized octagonal pole of 3mm thickness, with base plate including cost of nut and bolts , earthing studs, Integral Cable termination arrangement 5 mm thick Bakelite base plate on suitable welded MS/GI bracket 32 A four way connector 2 no 10 A SP MCB , end cover and all accessories as supplied by the manufacture including Providing RCC foundation of M25 grade (1 Cement:1 Stone aggregate: 2 Coarse sand) i/c excavation, steel reinforcement (Fe 500) @80 kg/cum of concrete contents, concrete cover 50mm, anchor bolts etc. over a bed of PCC 1:5:10 of required dimensions for octagonal poles of various heights as per following specifications complete in all respects and as per directions of Engineer-in-charge6 Metre Long pole with top dia 75 mm and bottom dia 150 mm with base plate of size 275 x 275 x 16 mm (HSR 24.4.8.4) |
| 439 | MISCELLANEOUS ITEMS 2.3. S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Metre below ground level including digging and refilling of earth including cost of suitable size socket/coupler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work.DWC/HDPE pipe 63/50 mm outer dia/inner dia (HSR 24.5.2.3) |
| 440 | RCC FOUNDATIONS FOR DG SET 5. 250 KVA DG Set (HSR 24.7.5) |
| 441 | FITTING AND ACCESSORIES 1.7. Providing and fixing Piano type accessories of approved make in existing box and Bakelite sheet including fixing and making necessary connections, complete in all respect. Electric buzzer 220/230 volts A.C. Bakelite with double coil. (HSR 23.8.1.7) |
| 442 | FITTING AND ACCESSORIES 4. Supply and erection of 10.5 cm dia M.S.Fan box including 8 mm dia 30 cm long M.S. Road made into suitable suspension hook and erected in R.C.C. slab for the erection of fan complete with all labour and material required to complete the job. (HSR 23.8.4) |
| 443 | FITTING AND ACCESSORIES 10.1. Providing and fixing GI concealed sheet metal boxes with inner and outer face plate including concealing the box in wall and fixing in position with inner plate and face plate with all labour and material required for the job complete in all respects. 1 & 2 Modules including combined plate for Telephone and data (HSR 23.8.10.1) |
| 444 | FITTING AND ACCESSORIES 10.5. Providing and fixing GI concealed sheet metal boxes with inner and outer face plate including concealing the box in wall and fixing in position with inner plate and face plate with all labour and material required for the job complete in all respects. 8 Modules (HSR 23.8.10.5) |
| 445 | FITTING AND ACCESSORIES 11.1. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. 5 amp 1 way switch (HSR 23.8.11.1) |
| 446 | FITTING AND ACCESSORIES 11.3. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. 15 amp 1 way switch (HSR 23.8.11.3) |
| 447 | FITTING AND ACCESSORIES 11.4. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. 5 amp Socket (HSR 23.8.11.4) |
| 448 | FITTING AND ACCESSORIES 11.5. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. 15 amp 6 pin Socket (HSR 23.8.11.5) |
| 449 | FITTING AND ACCESSORIES 11.7. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. step type Fan Regulator 2 modules 300 watt (HSR 23.8.11.7) |
| 450 | FITTING AND ACCESSORIES 11.8. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. Telephone Socket outlet modular type (HSR 23.8.11.8) |
| 451 | FITTING AND ACCESSORIES 11.11. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. RJ 45 Computer DATA socket outlet for CAT 6 or CAT6e cable Modular type (HSR 23.8.11.11) |
| 452 | FITTING AND ACCESSORIES 11.12. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. USB Charger, 1000mA, 5V, 1 Module( For Non residential use only) (HSR 23.8.11.12) |
| 453 | FITTING AND ACCESSORIES 13. Supplying,installation,testing and commissioning of Passive Infrared(PIR) based occupancy sensor , non regulating programmable type, suitable for connected load up to 10Amp , for mounting height up to 2.8 metre and for 5 m diameter coverage area along with necessary fixing arrangements i/c programming at site etc. complete as required. (HSR 23.8.11.13) |
| 454 | Providing and fixing outdoor duty Ply of 12 mm thick frame suitable for exhaust fan up to 450 mm sweep etc complete as required (HSR 23.12) |
| 455 | Fixing of LED Tube light/ 2*2 ft square panel fitting directly on wall /ceiling or false ceiling including making connections etc as required (HSR 23.20) |
| 456 | MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.11. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. 4 pole MCCB 200 to 250 amp, 25 KA (HSR 23.22.1.11) |
| 457 | MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 4.2. Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. SPN DB Double Door 8 way ( 2 incoming and 6 outgoing) (HSR 23.22.4.2) |
| 458 | MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 4.7. Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. TPN DB Horizontal type Double Door 8 way ( 8 incoming 3phase*8 outgoing) (HSR 23.22.4.7) |
| 459 | MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 4.11. Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. Vertical TPN DB Double Door 8 way ( 8 incoming 3phase*8 outgoing) (HSR 23.22.4.11) |
| 460 | MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.1. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 6 amp. to 32 amp Single Pole (HSR 23.22.5.1) |
| 461 | MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.3. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 6 amp. to 32 amp Double POLE (HSR 23.22.5.3) |
| 462 | MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.6. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 40 amp to 63 amp. MCBs TRIPLE POLE (HSR 23.22.5.6) |
| 463 | MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.8. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 40 amp to 63 amp. MCBs FOUR POLE (HSR 23.22.5.8) |
| 464 | MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 6.2. Supply and erection double pole/Four pole Residual (RCCB/ELCB) on 240/415V, 5Hz. AC supply installed in existing sheet steel enclosures including making necessary connections and bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. DP RCCB 30ma sensitivity , 40 A (HSR 23.22.6.2) |
| 465 | MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 6.3. Supply and erection double pole/Four pole Residual (RCCB/ELCB) on 240/415V, 5Hz. AC supply installed in existing sheet steel enclosures including making necessary connections and bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. DP RCCB 30ma sensitivity , 63 A (HSR 23.22.6.3) |
| 466 | MISCELLANEOUS 7.1. Supply and erection of cable tray cover made of 1.25 mm thick GI sheet as required including erection of the same on existing cable tray with necessary fixture and other material required to complete the job in all respect up to the entire satisfaction of Engineer-in Charge of the work. GI cable tray Cover , suitable for cable tray of 100 X 50 X 2 mm (HSR 23.22.7.1) |
| 467 | MISCELLANEOUS 9. Supplying and drawing of 1 no UTP 4 pair CAT 6 LAN Cable in the existing surface/recess MS/PVC conduit as required (HSR 23.23) |
| 468 | SAFETY ITEMS 1. Supply and erection of Medium Voltage caution notice plate of size 200*150 mm in three languages. (HSR 23.26.1) |
| 469 | SAFETY ITEMS 3. Supply and erection of shock restoration chart in glass frame. (HSR 23.26.3) |
| 470 | SAFETY ITEMS 4. Supply & Erection of mild steel bucket stand suitable for 6 Nos. fire buckets,(but without bucket) including the cost of welding and painting of complete stand will one coat of red oxide and 2 coats of approved paint of red colour with all labour and material required to complete the job in all respect up to the entire Satisfaction engineer in charge of the work (size 6x4 made of GI pipe 32mm dia). (HSR 23.26.4) |
| 471 | Supply and erection of Godrej Almirah typeM.S. pedestal made of 50 mm x 50 mm x 6 mm angle iron frame with 3.00 mm thick M.S. sheet covering including shutters with suitable hinges and locking arrangement with Godrej type handle including round bars . The top covering should have downward overhang of 75 mm on all sides of pedestal , having two sets of water proof ventilation holes of suitable size on the sides , at top and bottom , each set containing four Nos. holes to discharge the heat produced by the current . The shutters fixed with rubber gasket of superior quality and of suitable size to make it water proof . The pedestal duly painted both inside and outside with two coats of approved paint and primary coat and its legs are embeded upto the entire depth in 1:2:4 cement concrete block , projected 75 mm all around the pedestal and and 200 mm above the ground level including the cost of all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-in-charge of the work:- 1. M.S. pedestal of size 600 mm wide , 750 mm high ,300 mm deep and bottom totally open , duly embeded in 1:2:4 cement concrete block of size 750 mm x 450 mm x 200 mm above ground level , having a base of size 900 mm x 600 mm x 250 mm below ground level. (HSR 23.27) |
| 472 | CEILING FAN/ EXHAUST FAN Supply, erection, testing of Ceiling fans IS marked (as per IS code 374) with suitable GI pipe complete in all respects complete as per directions of Engineer-in-charge 1. 48\\" (1200mm) (HSR 20.71.1) |
| 473 | CEILING FAN/ EXHAUST FAN Supply, erection, testing of Ceiling fans IS marked (as per IS code 374) with suitable GI pipe complete in all respects complete as per directions of Engineer-in-charge 2. 56\\" (1400mm) (HSR 20.71.2) |
| 474 | CEILING FAN/ EXHAUST FAN Supplying, errection, testing of Exhaust fan (as per IS code 374) having a capacity of 45 cubic metre per minute complete with suitable G.I sheet ducting in structure confirming to latest IS specifications complete in all respect to satisfaction of Engineer-in-charge. (HSR 20.72.) |
| 475 | LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 18. 10Sq mm 4 core (Arm.) (HSR 24.13.18) |
| 476 | LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 24. 16Sq mm 4 core (Arm.) (HSR 24.13.24) |
| 477 | LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 82. 185Sq mm 3.5 core (Arm.) (HSr 24.13.82.) |
| 478 | LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 94. 300Sq mm 3.5 core (Arm.) (HSR 24.13.94.) |
| 479 | LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE ONSURFACE/ EXISTING CABLE TRAY COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 8. 6 Sqmm 2core (Arm.) (HSr 24.14.8.) |
| 480 | LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE ONSURFACE/ EXISTING CABLE TRAY COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 38. 35Sq mm 3.5 core (Arm.) (HSr 24.14.38) |
| 481 | LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE ONSURFACE/ EXISTING CABLE TRAY COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 46. 50Sq mm 3.5core (Arm.) (HSr 24.14.46) |
| 482 | HT CABLES (Aluminium Conductor, Armoured and Unarmoured) Providing and erection/ laying of XLPE (E) 11 KV HT Aluminium Conductor Armoured Cable ISI Mark Laid in Existing Pipe/Trenches/Surface with all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-In-Charge of the Works 4. Providing and erection/ laying of XLPE (E) 11 KV HT Aluminium Conductor Armoured Cable ISI Mark Laid in Existing Pipe/Trenches/Surface with all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-In-Charge of the Works 95 Sq mm 3 core (HSR 24.16) |
| 483 | PVC CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS 6.2. Supply and erection of PVC CONDUIT ISImarked (Medium) recessed in wall/ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC pipe of 25 mm dia. (HSR 23.7.6.2) |
| 484 | FITTING AND ACCESSORIES 11.8. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. Telephone Socket outlet modular type (HSR 23.8.11.8) |
| 485 | MISCELLANEOUS 9. Supplying and drawing of 1 no UTP 4 pair CAT 6 LAN Cable in the existing surface/recess MS/PVC conduit as required (HSR 23.23.9) |
| 486 | PVC CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS 6.2. Supply and erection of PVC CONDUIT ISImarked (Medium) recessed in wall/ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC pipe of 25 mm dia. (HSR 23.7.6.2) |
| 487 | PVC CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS 6.3. Supply and erection of PVC CONDUIT ISImarked (Medium) recessed in wall/ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC pipe of 32 mm dia. (HSR 23.7.6.3) |
| 488 | FITTING AND ACCESSORIES 11.8. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. Telephone Socket outlet modular type (HSR 23.8.11.8) |
| 489 | MISCELLANEOUS 9. Supplying and drawing of 1 no UTP 4 pair CAT 6 LAN Cable in the existing surface/recess MS/PVC conduit as required (HSR 23.23.9) |
| 490 | PVC CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS 6.2. Supply and erection of PVC CONDUIT ISImarked (Medium) recessed in wall/ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC pipe of 25 mm dia. |
| 491 | MISCELLANEOUS 9. Supplying and drawing of 1 no UTP 4 pair CAT 6 LAN Cable in the existing surface/recess MS/PVC conduit as required |
| 492 | EARTHING AND LIGHTENING ARRESTOR 1. Earthing with GL earth pipe 4.5 m long and 40 mm dia with masonry enclosures on the top etc. (but without charcoal or coke and salt) as required. (HSR 24.1.1) |
| 493 | EARTHING AND LIGHTENING ARRESTOR 2. Extra for using salt and char coal/coke for pipe earth electrode as required. (HSR 24.1.2) |
| 494 | EARTHING AND LIGHTENING ARRESTOR 11. Providing and laying earth connections from earth electrode with 4.00 mm dia G.I. wire in 15 mm dia G.I. pipe from earth electrode as required. (HSR 24.1.11) |
| 495 | EARTHING AND LIGHTENING ARRESTOR 13. Providing and fixing 4.00 mm dia G1. Wire on surface or in recess for loop earthing as required. (HSR 24.1.13) |
| 496 | STREET LIGHT 8.5. Supply and erection of Hot Dip Galvanized octagonal pole of 3mm thickness, with base plate including cost of nut and bolts , earthing studs, Integral Cable termination arrangement 5 mm thick Bakelite base plate on suitable welded MS/GI bracket 32 A four way connector 2 no 10 A SP MCB , end cover and all accessories as supplied by the manufacture including Providing RCC foundation of M25 grade (1 Cement:1 Stone aggregate: 2 Coarse sand) i/c excavation, steel reinforcement (Fe 500) @80 kg/cum of concrete contents, concrete cover 50mm, anchor bolts etc. over a bed of PCC 1:5:10 of required dimensions for octagonal poles of various heights as per following specifications complete in all respects and as per directions of Engineer-in-charge7 Metre Long pole with top dia 75 0mm and bottom dia 150 mm with base plate of size 300 x 300 x 20 mm (HSR 24.4.8.5) |
| 497 | MISCELLANEOUS ITEMS 2.3. S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Metre below ground level including digging and refilling of earth including cost of suitable size socket/coupler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work.DWC/HDPE pipe 63/50 mm outer dia/inner dia (HSR 24.5.2.3) |
| 498 | Supply and erection of Godrej Almirah typeM.S. pedestal made of 50 mm x 50 mm x 6 mm angle iron frame with 3.00 mm thick M.S. sheet covering including shutters with suitable hinges and locking arrangement with Godrej type handle including round bars . The top covering should have downward overhang of 75 mm on all sides of pedestal , having two sets of water proof ventilation holes of suitable size on the sides , at top and bottom , each set containing four Nos. holes to discharge the heat produced by the current . The shutters fixed with rubber gasket of superior quality and of suitable size to make it water proof . The pedestal duly painted both inside and outside with two coats of approved paint and primary coat and its legs are embeded upto the entire depth in 1:2:4 cement concrete block , projected 75 mm all around the pedestal and and 200 mm above the ground level including the cost of all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-in-charge of the work:- 1. M.S. pedestal of size 600 mm wide , 750 mm high ,300 mm deep and bottom totally open , duly embeded in 1:2:4 cement concrete block of size 750 mm x 450 mm x 200 mm above ground level , having a base of size 900 mm x 600 mm x 250 mm below ground level. (HSR 23.27.) |
| 499 | SOLAR PANELS Supply Installation testing commissioning of Solar Photovoltaic grid connected roof top Plant conforming to MNRE specifications as amended, consisting of Mono/Poly Crystalline silicon solar cells, net metering facility, necessary protections, earthing, mounted on Aluminium/GI structure of suitable strength with following components complete as required:-(a) Solar Photovoltaic Module manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730-Part-1, IS/IEC 61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 16.5%. PV modules used in solar power plants/ systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years.(b) Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 400 V AC, three phase, 4 wire, 50Hz plus /- 2.5 Hz, output voltage suitable to generate AC(c) Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degreesC. The PCU shall adjust the voltage and frequency level to suit grid frequency(d) Data Monitoring System complete with accessories.(e) Fixing of Array junction box and Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories etc. as required.(f) Lightning and surge voltage protection.(g) Connections and Interconnections by supplying and fixing required size XLPE insulated copper conductor 1.1 kV grade armoured power and control cables between solar modules, main power cable to grid supply PCU unit along with supplying and fixing of necessary channel/conduit lugs and other accessories etc. as required. 2. Above 10 kWp and up to 100 Kwp (HSR 32.70.2) |
| 500 | LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 18. 10Sq mm 4 core (Arm.) (HSR 24.13.18) |
| 501 | Central Air Conditioning : Low side Items Supply, installation, and commissioning of factory/site fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. 1. Thickness 0.63 mm sheet |
| 502 | Central Air Conditioning : Low side Items Supply, installation, and commissioning of factory/site fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. 2. Thickness 0.80 mm sheet |
| 503 | MISCELLANEOUS 9. Supplying and drawing of 1 no UTP 4 pair CAT 6 LAN Cable in the existing surface/recess MS/PVC conduit as required |
| 504 | SAFETY ITEMS 4. Supply & Erection of mild steel bucket stand suitable for 6 Nos. fire buckets,(but without bucket) including the cost of welding and painting of complete stand will one coat of red oxide and 2 coats of approved paint of red colour with all labour and material required to complete the job in all respect up to the entire Satisfaction engineer in charge of the work (size 6x4 made of GI pipe 32mm dia). (HSR 23.26.4) |
| 505 | LOFT AND TERRACE WATER TANKS Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. (HSR 22.181) |
| 506 | LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 54. 70Sq mm 3.5 core (Arm.) (HSR 24.13.54) |
| 507 | COPPER WIRING IN EXISTING PVC/MS CONDUIT PIPE SURFACE/RECESSED FOR ELECTRICAL POINTS 6.6. Wiring main and submains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in existing MS/PVC Conduit etc as required. 2 run of Size 1.50 Sqmm(1/1.40mm) (HSR 23.5.2) |
| 508 | Central Air Conditioning : Low side Items Supplying, fixing, testing and commissioning of Butterfly valves PN 16 rated without insulation for water circulation as per specifications. 4. 150mm dia. (HSR 25.3.4) |
| 509 | Central Air Conditioning : Low side Items Supplying, fixing, testing and commissioning of Butterfly valves PN 16 rated without insulation for water circulation as per specifications. 6. 100mm dia. (HSR 25.3.6) |
| 510 | Central Air Conditioning : Low side Items Supplying, fixing, testing and commissioning of Butterfly valves PN 16 rated without insulation for water circulation as per specifications. 7. 80mm dia. (HSR 25.3.7) |
| 511 | Central Air Conditioning : Low side Items Supplying, fixing, testing and commissioning of Butterfly valves PN 16 rated without insulation for water circulation as per specifications. 9. 50 mm dia. (HSR 25.3.9) |
| 512 | Central Air Conditioning : Low side Items Supplying, fixing, testing and commissioning o NON - RETURN VALVE with dual plate of C I body SS plates vulcanized NBR seal flanged end and PN 16 pressure rating as specified. 2. 150mm dia. (HSR 25.4.2) |
| 513 | Central Air Conditioning : Low side Items Supplying, fixing, testing and commissioning o NON - RETURN VALVE with dual plate of C I body SS plates vulcanized NBR seal flanged end and PN 16 pressure rating as specified. 4. 100mm dia. (HSr 25.4.4) |
| 514 | LOFT AND TERRACE WATER TANKS Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. (HSR 22.181) |
| 515 | Supply, installation, testing and commissioning of 60W LED Post Top Light - Supply of Pole mounted LED Post Top luminaire,luminous efficiency of luminaire = 100 lm/W colour rendering index Ra ) 70. Service life L70(tq 25 °C) = 50,000 h,CCT-3000K.Pressure die cast aluminium housing with Luminaire cover made of Polycarbonate/PMMA ,symmetrical wide light distribution and Ingress Protection rating IP65 . Power Factor = 0.95, THD should be = 10%. Surge protection should be = 10kV . All luminaires shall be with associated driver , lamp and other connecting or mounting accessories to make it complete in all respect for operational purpose. The supplier shall submit the technical specification sheets alongwith LM reports for approval. |
| 516 | Supply and erection of LED Light 36 Watt 2`x2` Size (surface/Recess Type) efficiancy 100lm/w burnning 50000 hrs operation on single phase AC Supply full lit luminaire with uniform illumination with longer life and less maintenance PF = 0.95, THD = 10%, CRI = 80, SDCM = 5, Lifetime L70 = 50,000 hrs, BIS plus LM79 plus LM80, IP20, Class II, Driver surge protection = 2.5 kV,complete in all respect up to the entire satisfaction of engineerin charger of the work including making necessary connection. Make as per HPHC approved Brand List |
| 517 | SITC of LED Light 20 Watt 4 feet long operation on single phase AC Supply including inbuilt LED Driver with constant current. lumens= 100 lumens /watt , 6500 K Cool white colour, input voltage 220-240,frequancy 50 Hz, power facto = 0.85, Protection IP20 for indoor and IP = 65 for outdoor fixtures. The body die cast aluminium powder coated. Temprature range -10 degree to plus 45°,THD (10%, buring hours = 20000 Hours BIS Certified Complete in all respect. Make as per HPHC approved Brand List |
| 518 | SITC of 12W IP20 recessed LED Downlightermade of pressure die cast aluminum housing with PC diffuser,Fixture should have minimum efficacy at System level (NotChip Level) )=100 lumens/watt with Minimum system Lumens 1200 with maximum system wattage of 12W. Life of fixture (Including Driver) : 50000 burning Hrs. Lumen maintenance, CCT of 6500K (SDCM (5), CRI )80, PF =0.85, THD(10% (At Full Load) working temp range -0°C ( Ta ( 45°C, and operating Voltage Range of 130-320 VAC. It should has a Minimum Internal Surge Protection of 2.5KV. Electronic Switchable ballast. The fixture should have BIS certification with allied items complete in all respect |
| 519 | Supply, Installation, Testing and Commissioning of Digital Hybrid IP-PBX System configured for 04 Analog Trunk Connectivity, 04 Digital Extensions, 48 Analog Extensions. It should be possible to reach the capacity of system to 48 ports and 99 IP users without any add-on CPU or chassis/hardware platform. System should have two Gigabit Ethernet ports for LAN and WAN to separate out local and VoIP traffic on external network.It should be suitable for DTMF as well as the FSK type of telephone instruments. It should have built-in multi-party conferencing without any software licensing. It should be possible to carry out 15 conferences of 3-participants at a time. The system shall have built-in web based software programming tool for system administration. The call ringing sequence would be programmable and have options such as simultaneous, hunting off, round robin and delayed simultaneous.The system shall support flexible numbering for extensions such as it may have extensions with 1 digit, 2 digits and up to 6 digits numbers as well as in combination of all.The system should have built-in outgoing Call Log buffer of 6000 calls, incoming call log buffer of 5000 and call log buffer of 1000 internal calls. Operator features shall have the assistance to extension, attended call transfer, call intercept, indication of call waiting, night service control etc. should be available by default. Make : Avaya/Alcatel/Matrix |
| 520 | Supply, Installation, Testing and Comissioning of Operator Console :Supply, Installation, Testing and Comissioning of Digital DSS having 32 Direct Keys compatible with the PBX and its console.With option to add multiple DSS with the console. Phone Features Message wait Lamp, Ringer Lamp. Make : Avaya/Unify/Matrix |
| 521 | Supply, Installation, Testing and Comissioning of s Digital Phone with large Backlit Display of 240x60 Pixels Graphic LCD, 4 Context Sensitive Keys ,Built-in 16 DSS Keys,High Quality Full Duplex Speaker Phone Features Call Forward, Waiting, Transfer, Hold, Conference, Redial, Ringer Lamp.Must have storage for minimum 20 calls per call log in the console itself. Make : Avaya/Unify/Matrix |
| 522 | Supply, Installation, Testing and Commissioning of 1 KVA Online UPS Overvoltage cut-off device (OVCD), input 110 – 300 Vac) AC, Support for up to SMF batteries min. 3 nos. 12V/ 42 AH external battery cabinets (quantity of batteries should be as UPS output/ backup min 1 hour) , discharge/overcharge, cold start, auto restart, operating 0–40°C, humidity up to 95%, noise (40 dB, Generator Compatible with Wide Input. Wide Input Voltage window (110 – 300 Vac) for Indian Environmental Condition and for Optimized Battery Performance. UPS would support SNMP Manager and web browser On Line With 1 hour Backup. Make: APC/ Vertiv/ EATON |
| 523 | Supply, installation, Testing and Commissioning of 24 port POE plus Switch, Layer-2, Smart managed having 24 PoE ports (1G) and 4 Gigabit uplinks / SFP slots (10G), Standard: 1EEE 802.3at (POE plus ), Power range min. 190 watt complete in all respect as per entire satisfaction of Engineer-in-charge. OEM should provide replacement with New product, No Refubrish products. Make: Cisco/ Netgear/Juniper/Alcatel /Extreme. |
| 524 | Supply, Installation, Testing and Comissioning of Caller ID Corded Landline Phone with 16 Digit LCD Display and Adjustable contrast,10 One Touch Memory Buttons,2Ways SpeakerPhone,Music On Hold,Solid Build Quality,. Make :-Beetel M59N /Panasonic/Matrix |
| 525 | Supply, Installation, Testing and Commissioning of IDF/MDF with MS Box duly painted and having lock facilities iii) 20 pair. Make- FAAC, Neptune, Matrix, Krone |
| 526 | Supply, Installation, Testing and Commissioning of IDF/MDF with MS Box duly painted and having lock facilities ii) 50 pair. Make- FAAC, Neptune, Matrix, Krone |
| 527 | SE of 1.5 sqmm 3 core copper flexible cable armoured Complete in all respect |
| 528 | Supply, Installation, Testing and Comissioning of 2 core multistrand 1.5 sq mm annealed copper conductor Fire alarm and speaker cable in existing pipe/ channel I/C connection etc. Make:- Finolex/ Polycab/ havel`s |
| 529 | Supply, Installation, Testing and Comissioning of 2 core 1.5 sq mm armoured cable. Make:- Finolex/ Polycab/ havel`s |
| 530 | Supply, Installation, Testing and Commissioning of 1 KVA Online UPS Overvoltage cut-off device (OVCD), input 110 – 300 Vac) AC, Support for up to SMF batteries min. 3 nos. 12V/ 42 AH external battery cabinets (quantity of batteries should be as UPS output/ backup min 1 hour) , discharge/overcharge, cold start, auto restart, operating 0–40°C, humidity up to 95%, noise (40 dB, Generator Compatible with Wide Input. Wide Input Voltage window (110 – 300 Vac) for Indian Environmental Condition and for Optimized Battery Performance. UPS would support SNMP Manager and web browser On Line With 1 hour Backup. Make: APC/ Vertiv/ EATON |
| 531 | Supply, Installation, Testing and Commissioning of controller unit 6-zone system pre-amplifier 240 amplifier Inbuilt Bluetooth and USB pen drive. Two input channels for call stations , Universal input for microphone/line, with speech optimized tone control , Three inputs for BGM selection and music optimized tone control , Front panel zone selection for BGM and call station zone selection for calls, S/N (flat at max volume) )63 dB (mic): )70 dB (line), S/N (flat at min volume/muted) )75 dB, CMRR )40 dB (50 Hz – 20 kHz),Line input 3 x, Master output 1 x, Frequency response 50 Hz to 20 kHz ( plus 1 / -3 dB) complete in all respect Make:- Notifire / Bosch/Simens |
| 532 | Supply, Installation, Testing and Commissioning of Stylish 6-zone call station, Six zone selection keys, all call key and momentary PTT-key for calls Selectable gain, speech filter and limiter for improved intelligibility LED indications for zone selection, fault and emergency state Voltage range 18 – 24V Nominal sensitivity 85 dB SPL (gain preset 0dB) Gain preset plus 6 / 0 / -15 dB Equivalent input noise level 25 dBSPLA Frequency response 100Hz – 16kHz complete in all respect Make:- Honeywell/ Bosch /SIMENS/ NOTIFIRE |
| 533 | Supply, Installation, Testing and Comissioning of 480W Booster amplifier , Battery voltage -24Vdc (max.10%deviation), Frequency response-60Hz to 15 kHz( plus 1/-3 db), Distortion (at rated out power ar 1 khz)- (3%, Inputs- XLR , Impendence-20k , Sensitivity-1V (mic inputs), S/N-)80 DB. Make:- Notifire / Bosch /Simens |
| 534 | Supply, Installation, Testing and Comissioning of UTP cat 6 Mounting Patch Cords Low smoke zero helogene (LSZH/LS0H ) complete in all respect upto the entire satisfaction of Engineer-in-Charge of the work Make:- Molex/RandM/Semon . a)3 FT length |
| 535 | Supply, Installation, Testing and Comissioning of UTP cat 6 Mounting Patch Cords Low smoke zero helogene (LSZH/LS0H ) complete in all respect upto the entire satisfaction of Engineer-in-Charge of the work Make:- Molex/RandM/Semon b) 7FT length |
| 536 | Supply, Installation, Testing and Comissioning of UTP cat 6 24 port jack pannel complete in all respect upto the entire satisfaction of Engineer-in-Charge of the work Make:- Molex/RandM/Semon |
| 537 | Supply, Installation, Testing and Comissioning of 24 Port SFP plus Layer-3 Stackable Managed Switch. 24 # 1/10G Base-X SFP plus Port 4 # 1/10G/25G SFP plus Ports Out of band : 1 x RJ45 10/100/1000BASE-T (back) Console: USB-C (front) 2 x USB-A (back) Full width 1U rack mount Quad-Core Cortex-A57 ARMv8 1.8Ghz 64-bit RAM: 2 GB Packet buffer memory: 32 MB Flash: 512 MB Stack height: 8 switches Switching fabric: 680 Gbps Line-Rate (non blocking fabric) Address database size: 16,000 MAC addresses (48-bit MAC address) Number of VLANs: 4,093 (IEEE 802.1Q) simultaneously ARP/NDP= 4K/512 Number of LAGs (802.3ad): 128 LAGs with up to 8 ports per group Number of routes: 894 IPv4 Unicast routes Mean time between failures (MTBF):778,741 hours (~88.9 years) Protocol based VLAN , ARP,IPX Private Edge VLAN Double VLAN Tagging (QoQ) GARP with GVRP/GMRP Multiple Registration Protocol (MRP) Per VLAN STP (PVSTP) with FastUplink and STP Loop GuardFastBackbonePer VLAN Rapid STP (PVRSTP) IGMP v2/v3 Snooping support MLD v1/v2 Snooping support Static Routing (IPv4, IPv6) Port Based Routing OSPF v2 and v3 DNS v4 and v6 Broadcast, Multicast and Unicast Network Storm Protection Management ACL CE mark, commercial FCC Part 15 Class A, VCCI Class A Class A C-Tick EN 50082-1 CSA certified (CSA 22.2 #950) UL listed (UL 1950)/cUL IEC 950/EN 60950 ODM vendor should be ISO certified. OEM should provide replacement with New product, No Refubrish products. Make: Cisco/ Netgear/Juniper. |
| 538 | Supply, Installation, Testing and Comissioning of Single Mode Fiber Module, 10GBase-LR Fiber SFP plus LC duplex connector 1310nm Wavelength 2m - 10km for 9/125 um SMF Single Mode Fiber ROHS Compliant Compliant with SFP plus Transceiver MSA specification Compliant with Specifications for IEEE 802.3ae 10-Gigabit Ethernet Over Fiber Compliant with Industry Standard RFT Electrical Connector and Cage Operating Temperature 32 -158º F (0 - 70ºC) UL 1950 CSA 22.2 No. 950 OEM should provide replacement with New product, No Refubrish products. Make: Cisco/ Netgear/Juniper. |
| 539 | Supply, Installation, Testing and Comissioning of 12 U rack with cable manager, fan tray, power distribution kit complete in all respect. Make: Comrack/Netrack/Valrack |
| 540 | Supply, Installation, Testing and Comissioning of MK Channel NCT 1050 ( 100mm x 50mm ) |
| 541 | Supply, installation, Testing and Commissioning of 24 port POE plus Switch, Layer-2, Smart managed having 24 PoE ports (1G) and 4 Gigabit uplinks / SFP slots (10G), Standard: 1EEE 802.3at (POE plus ), Power range min. 190 watt complete in all respect as per entire satisfaction of Engineer-in-charge. OEM should provide replacement with New product, No Refubrish products. Make: Cisco/ Netgear/Juniper/Alcatel /Extreme. |
| 542 | Supply, Installation, Testing and Comissioning of 9U indoor network rack suitable for wall mounting, conforming to DIN 41494, EIA- 310 and IEC 60297 standards, made of CRCA steel sheet of thickness 1.0–1.2 mm (frame) and 0.8–1.0 mm (door) with powder coated finish, 19” mounting angles, lockable toughened glass front door with ventilation slots, top/bottom cable entry, with 1–2 nos. cooling fans, static load up to 25 kg,PDU complete with mounting brackets and accessories,as per the specifications, complete in all respect upto the entire satisfaction of Engineer - in - Charge of the work. Make: Nordon/Rittal/Comrack/Valrack. |
| 543 | Supply, Installation, Testing and Comissioning of 3 KVA Online UPS Overvoltage cut-off device (OVCD), input 110 – 300 Vac) AC, Support for up to SMF batteries min. 6 nos. 12V/ 42 AH external battery cabinets (quantity of batteries should be as UPS output/ backup min 1 hour) , discharge/overcharge, cold start, auto restart, operating 0–40°C, humidity up to 95%, noise (40 dB, Generator Compatible with Wide Input. Wide Input Voltage window (110 – 300 Vac) for Indian Environmental Condition and for Optimized Battery Performance. UPS would support SNMP Mnagaer and web browser On Line With 1 hour Backup. Make: APC/ Vertiv/ EATON |
| 544 | SITC of 60 kVA/ 60kw, 3-phase (3:3, 3:1, 1:1) true online UPS with double conversion IGBT technology, UPS Supply of 3 No`s 20 KVA/20KW, input 320–480V, PF =0.995, THD -1%, output 415V, 50Hz ±0.1%, pure sine wave, efficiency =94%, output, unity output pf, input pf= 0.955, THDi =3% linear load and 5% non-linear load, THDv= 1% linear load and 3% non-linear load , Voltage variation =±1%, Overload capacity line mode (at rated Voltage)= 105%( Load 125%: 10min, 125%( Load 150%: 1min, )150% :0.5sec., overload 110%–150%, with SMF batteries 12V, 65Ah (quantity of batteries should be as UPS output/ backup time =30 min), backup time =30 min, operating 0–60°C, humidity up to 95%, noise (40 dB, DC bus 360–480V, complete with bypass, cables, racks, conforming to IEC standards 62040 series, complete in all respect as per entire satisfaction of Engineer-in-Charge. Make= APC/ Vertiv / EATON |
| 545 | Supply, Installation, Testing, Commissioning of 5MP Bullet Camera with 2.8-12mm Motorized Varifocal lens, 1/2.8` SONY - CMOS 5MP Active Pixel, Minimum Illumination - Color - 0.01 Lux @F1.2, Focal Length - 2.8mm — 12mm, Focus Range - 0.3m to infinity, Aperture (F#) - F1.6-F2.8, Iris Type - Motorized Varifocal Iris, IR Range - Up to 50m, IR Led Wavelength - 850nm, IR Switching - Auto/ Manual, Audio IN - 1, Audio OUT - 1, Two-way Audio -Supported, Audio Compression - G.726 and G.711g, Alarm In - 1 (Phoenix type connector), Alarm Out - 1 (Phoenix type connector), SD Card - Up to 512GB, Camera Adjustment Angle - Pan: 0° to 360°, Tilt: 0° to 90° , Rotate: 0° to 360°, Available Resolutions - 2592 x 1944, 2592 x 1520, 2048 x 1536, 1920 x 1080, 720p, D1, 2CIF, CIF, Max Resolution - 2592 x 1944, Bitrate - 128 kbps-16Mbps, Bitrate Type - CBR, VBR, Video Compression - H.265, H.264, MJPEG, Frame Rate - 1-30fps, Shutter Speed - 1/15s -1/100000s, Adaptive Streaming - Yes, ONVIF Profiles - S, G, and T, Edge Recording - Yes, Alarm Recording - Pre and Post, Motion Recording - Yes, Time Triggered - Yes, WDR True - WDR (120dB), SNR - )70dB, Storage - NAS, SD Card, Certifications - NDAA Compliant, BIS, CE, IP67, FCC Part-15 Subpart - B, ONVIF S, G and T,IK10,UL, NEMA 4X**, STQC Certified with OWASP ASVS 4.0L2, SIRA. Make: Matrix/ Bosch/ Norden |
| 546 | Supply, Installation, Testing, Commissioning of ANPR Software For 4 Cameras With 2 Concurrent User Licenses, System shall support the Indian standard license plate recognition (LPR) system irrespective of state: type (car: jeep: truck: multi-axle containers etc.) and vehicle category (commercial and private). License plate recognition algorithms should be designed and developed based on recent neural network sets of Deep Learning technologies for best possible accuracy and correct results.System shall support the central LPR process of all the streams and storage of all vehicle related data. System shall have provision to detect the license plate from camera stream and identify license plate digits of vehicle along with the vehicle images and timestamp. Identified license plate image and digitally converted license plate data along with the full vehicle image shall be stored for future reference.System shall support the configuration of add: edit: delete of vehicle zone for configuring the field of view: sensitivity or confidence percentage score and license plate event from central location. Client Software shall have provision for showing the live detection or Licence Plate events with captured vehicle images as well as digitally converted license plate data. For future reference, Operators shall be able search the historic vehicle records based on the stipulated time frame. It shall have provision to search and filter based on the recognised license plate digits. System shall support the defined retention data management system to remove the past data for smooth process. For Evidence purpose, System Client software shall embed the recorded video with LPR event for ease of use. On clicking the Playback icon with event data, It shall play the recorded video clip at the time of vehicle detection. System shall support the identification of vehicle based on predefined vehicle and user database for vehicle categorization. System shall support the runtime alarm in case of blacklisted or suspected category vehicles identified within the installation zone of IP camera. System shall support the Data analytic Report of LPR events with captured images. As a part of digital data backup, Admin shall be able to schedule the Report Generation et every Day or Week to avoid manual interventions. Make: Matrix/ Bosch/ Norden |
| 547 | Supply, Installation, Testing, Commissioning of 64 Channel 4K Network Video Recorder with 8 Sata Ports , Processor Quad-core embedded processor, Operating System Embedded LINUX, User Interface GUI, Video Output 1 HDMI , 2 VGA , Video Resolution HDMI1: 1280x720,1920x1080, 3840x2160`, Channel 64 channel, Hard Disk 8 SATA III ports, up to 10TB Each, 1 eSATA port, Recording Mode Manual, Schedule (Regular, MD (Motion Detection), Alarm, IVS), Stop, Backup Mode, USB Device/Network, Resolution 12MP, 8MP, 6MP, 5MP, 4MP, 3MP, 1080P, 1.3MP, 720P etc. Ethernet 2 RJ-45 port (10/100M/1000Mbps) Independent or Joint Working, Interface Ports 3 USB ports (2 x USB 2.0, 1x USB 3), Certifications CE, FCC, BIS/UL, ROHS. Make: Matrix/ Bosch/ Norden |
| 548 | Supply, Installation, Testing and Comissioning of Switch should be Web Manged, Should have 8 port 1000BASE-T with 4 Port 1000BASE-T PoE PoE power budget 160 Watt or higher, Maximum Per port PoE Power 30 WattIEEE 802.3 10BASE-T Ethernet, IEEE 802.3u 100BASE-TX Ethernet,IEEE 802.3ab 1000BASE-T Ethernet, IEEE 802.3az EEE support,IEEE 802.3x flow control,IEEE 802.3z 1000BASE-X,IEEE 802.1p CoS,IEEE 802.3af PoE, IEEE 802.3at PoE Plus, IEEE802.1Q VLAN Tagging, Minimum 8 VLANsupportPort based VLAN, IEEE802.3ad link aggregation should be MAC based Switching Capacity 16 Gbps,Packet buffer 192KB,MAC address support 4K Jumbo frame support 9K, Should support loop detection,Should support Broadcast storm control QoS Support (WRR and strict priority) Port based QoS 20 Multicast group or higher, Maximum power consumption 72W,Operating temperature 0°C to 40°C Storage Temperature -40°C to 70°C Certification: CE, FCC, C-Tick, , LVD EN60950-1, ROHS compliant.Should be built-in IEEE 802.3az Energy Efficient Ethernet (EEE) Make: Alied /Juniper / Netgear/ Zyxel. |
| 549 | Supply, Installation, Testing and Comissioning of SFP 1G Ethernet Fiber Module for Managed Switches. Gigabit Ethernet “short- reach” fiber connectivity, LC duplex connector, Fits into SFP interfaces of all Fully Managed ,Switches. Drives Gigabit Ethernet up to 1,000 m distances with 50/125µm laser-optimized OM4 multimode fiber cables, Drives Gigabit Ethernet up to 550 m distances with 50/125µm laser-optimized OM3 multimode fiber cables, Drives Gigabit Ethernet up to 275 m distances with 62.5/125ìm OM1 multimode fiber cables. Make: Cisco/ Netgear/Juniper. |
| 550 | Supply, Installation, Testing and Comissioning of Patch Panel Cat 6 UTP Keystone Type- 24 Port-Fully Loaded. Category 6 24 port Patch Panel should be 24 Port 1U Size loaded with 24 port RJ-45 IO. Mounts in standard 19 inch racks.Patch panel should have cable manager for improvement management. Patch panel suitable for Category 6 keystone. Panel material should have SPCC and Black Color. Rear support bar material should have SPCC and Black Color. RJ-45 jack housing should be PBT plus Glass fiber UL94V-O and Contact brackets should be PBT plus Glass fiber UL94V-O. Rj-45 contact material should be phosphor bronze with nickel plated and plug contact area finish with 50 micro-inches Gold plated. Make Dlink/Molex/RandM/Panduit |
| 551 | Supply, Installation, Testing and Comissioning of Patch Cord,CAT6 UTP 1M LSZH Patch Cord - Grey, patch cords with four pair twisted cable terminated with RJ45 modular plugs at both the ends. Patch Cord should have TIA/EIA 568C.2 standard. Shall be backward compatible with Category 5 and Category 5e systems. patch cord should be 100% factory made and performance tested. length requires – 1 meter and 2 meter and 3 meter. Patch cord conductor should be 24 AWG, multi-strands. Patch core conductor metal should be made from bare copper. Make Dlink/Molex/RandM/Panduit |
| 552 | Supply, Installation, Testing and Comissioning of LIU 12 Port Rack Mount - Loaded with (LC ) SM pigtails, Loaded LIU shall accommodate Simplex/Duplex SC Single mode adapters. Aluminum base Material with Powder Coating for light mounting, Adapter panel - Cold Steel, 1.5mm Thickness, Rubber fiber slotted bracket built-in, metal splice shelf to protect the fibers, 4 Fiber spools Built- In for 900um tight buffered Fiber Storing, Shall be Capable of Storing 3 Meters of 900um tight buffered fiber per adapter. Snap-in locker design, easy to change adapter panels for various connector patching, Accessory kit consists of cable ties, mounting ear screw and spiral wrap tube, cable saddle. Fiber patch Panel should have fiber magic sticker provision inside for 900um tight buffered fiber storing, Fiber patch Panel should have Front-Mounted Cable Saddles for jumper management Make Dlink/Molex/RandM/Panduit |
| 553 | Supply, Installation, Testing and Comissioning of LC to LC Cable,LC-LC Single Mode Duplex Patch Cord, 1-meter length, Optical fiber patch leads shall comprise of Single mode 9/125µm fiber with LC-LC fiber connectors terminated at each end.The optical fiber patch leads shall be compatible with industry standards (EIA/TIA, IEC, ANSI). Adopts high precision ceramic ferrule with good concentricity. 100% inspected for optical characteristics and fiber end face finish. Low insertion loss and return loss, clean and scratch-free end faces. Good performance endurance under changing circumstances. 9/125µm Single mode G652D, Duplex Type, Pre-radiuses and pre-polished ferrule Make Dlink/Molex/RandM/Panduit |
| 554 | Supply, Installation, testing and commissioning of 6 core Single Mode Optical Fiber Cable . Make: RandM / Siemon/ Systimax/Dlinkonly. |
| 555 | Supply, Installation, Testing and Comissioning of 65` 4KUHD resolution LED Display with Android 11, 400 nits brightness, Cortex A551.3Ghz processor, Mali G31 MP2, Open GLES3.2, 2 GB DDR RAM, 16 GB Memory, Wifi Type support both 2.4 and 5G Standard, Dolby Audio, Built in Wifi and Cromecast, HDMI CEC, HDMI ARC, Built-in Bluetooth, Hotel mode, Meeting Mode,20W built in speakers, HDMI 2.0 X 2, AV X 1, USB X 2, RJ45 X 1, SPDIF Out x 1,24/7 operational. Make: Panasonic /Samsung /LG/Sony. |
| 556 | Supply, Installation, Testing and Comissioning of 5 Mtr HDMI cable Connectors at both ends Make :-Key Digital/Manhattan/Kramer |
| 557 | Supply, installation, Testing and Commissioning of 24 port POE plus Switch, Layer-2, Smart managed having 24 PoE ports (1G) and 4 Gigabit uplinks / SFP slots (10G), Standard: 1EEE 802.3at (POE plus ), Power range min. 190 watt complete in all respect as per entire satisfaction of Engineer-in-charge. OEM should provide replacement with New product, No Refubrish products. Make: Cisco/ Netgear/Juniper/Alcatel /Extreme. |
| 558 | Supply, Installation, Testing and Comissioning of 9U indoor network rack suitable for wall mounting, conforming to DIN 41494, EIA- 310 and IEC 60297 standards, made of CRCA steel sheet of thickness 1.0–1.2 mm (frame) and 0.8–1.0 mm (door) with powder coated finish, 19” mounting angles, lockable toughened glass front door with ventilation slots, top/bottom cable entry, with 1–2 nos. cooling fans, static load up to 25 kg,PDU complete with mounting brackets and accessories,as per the specifications, complete in all respect upto the entire satisfaction of Engineer - in - Charge of the work. Make: Nordon/Rittal/Comrack/Valrack. |
| 559 | Supply, Installation, Testing and Comissioning of 3 KVA Online UPS Overvoltage cut-off device (OVCD), input 110 – 300 Vac) AC, Support for up to SMF batteries min. 6 nos. 12V/ 42 AH external battery cabinets (quantity of batteries should be as UPS output/ backup min 1 hour) , discharge/overcharge, cold start, auto restart, operating 0–40°C, humidity up to 95%, noise (40 dB, Generator Compatible with Wide Input. Wide Input Voltage window (110 – 300 Vac) for Indian Environmental Condition and for Optimized Battery Performance. UPS would support SNMP Mnagaer and web browser On Line With 1 hour Backup. Make: APC/ Vertiv/ EATON |
| 560 | Supply, Installation, Testing and Commissioning of 65` LED TV Display, commercial type, 4K UHD, 24X7 , minimum brightness 500 NITS or above, HDMI x 2, resolution (3840 × 2160), wall mounted / floor stand as per required, make HPHC Brand list |
| 561 | Supply, Installation, Testing and Comissioning of 5MP Dome Camera with 2.8-12mm Motorized Varifocal lens, 1/2.8` SONY - CMOS 5MP Active Pixel, Minimum Illumination- Color - 0.01 Lux @F1.2, Focal Length - 2.8mm - 12mm, Focus Range - 0.3m to infinity, Aperture (F#) - F1.6-F2.8, Iris Type - Motorized Varifocal Iris, IR Range - Up to 50m, IR Led Wavelength - 850nm, IR Switching - Auto/ Manual, Audio IN - 1, Audio OUT - 1, Two-way Audio -Supported, Audio Compression - G.726 and G.711g, Alarm In - 1 (Phoenix type connector), Alarm Out - 1 (Phoenix type connector), SD Card - Up to 512GB, Available Resolutions - 2592 x 1944, 2592 x 1520, 2048 x 1536, 1920 x 1080, `720p, D1, 2CIF, CIF, MaxResolution - 2592 x 1944, Bitrate - 128 kbps-16Mbps, Bitrate Type - CBR, VBR, Video Compression - H.265, H.264, MJPEG, Frame Rate - 1- 30fps, Shutter Speed - 1/15s - 1/100000s, Adaptive Streaming - Yes, ONVIF Profiles - S, G, and T, Edge Recording - Yes, Alarm Recording - Pre and Post, Motion Recording - Yes, Time Triggered - Yes, WDR True -WDR (120dB), SNR - )70dB, Storage - NAS, SD Card, Certifications - NDAA Compliant, BIS, CE, IP67, FCC Part-15 Subpart — B, ONVIF S, G and T,IK10 STQC certified. Make: CP PLUS/PRAMA//Matrix/ Bosch/ Norden` |
| 562 | Supply, Installation, Testing and Commissioning of 10 TB surveillance Hard disk Make: WD/Seagate/Toshiba capacity 10TB Connector SATA Interface SATA Operating Temperature 0°C to 65°C Certifications BSMI, CE, UL |
| 563 | `NS Item -Supply, Installation, Testing and Commissioning of of PC Client Intel i7, 13th generation processor with clock speed- minimum 3.0GHz, RAM8 GB and Expandable. Window 10 or Window 2016 Server or Unix based Edition .Minimum 512 GB . LAN Interface 10/100/1000 Mbps Ethernet.).. Mouse Optical . USB port at front and Software of cameras.1. Processor (CPU)Make: IntelModel: Core i7 (13th or latest available generation at time of supply) Base Clock Speed: Minimum 3.0 GHzCores: Minimum 6 cores (preferably 8 or more) Threads: As per processor standardCache: Minimum 12 MB Smart Cache2. Memory (RAM)Installed RAM: 8 GB DDR4 / DDR5Expandability: Up to 16 GB / 32 GB (minimum 2 DIMM slots) RAM Speed: Minimum 2666 MHz or higher3. Storage Primary Storage:Minimum 512 GB SSD (Preferred)(or 512 GB HDD if SSD not specified, but SSD strongly recommended) Interface: SATA / NVMe (NVMe preferred for performance) Expandability: Provision for additional storage (HDD/SSD slot)4. Operating System Compatible OS Options:Windows 10 Professional (64-bit) OR Windows Server 2016 ORUnix/Linux-based OS (Ubuntu/CentOS or equivalent)OS License: Genuine and activated (if Windows supplied)5. Networking (LAN Interface) Ethernet Port:10/100/1000 Mbps (Gigabit LAN) RJ-45 Port: 1 x minimumSupport for standard TCP/IP networking6. Ports and Connectivity USB Ports:Minimum 4 USB portsAt least 2 USB ports on front panel Video Output:HDMI / DisplayPort / VGA (minimum one) Audio:Mic-in and Line-out / Combo jack Additional Ports:Ethernet (RJ-45)Optional: USB 3.0 / USB-C7. Input Devices Keyboard:USB wired keyboard (standard layout) Mouse:Optical USB mouseMinimum 2 buttons plus scroll wheel8. GraphicsIntegrated Graphics (Intel UHD or better) Capable of Full HD display (1920×1080)9. Cabinet Type: Desktop /Cooling: Adequate ventilation with internal fans Build: OEM branded or industrial-grade10. Power SupplySMPS: Standard certified (minimum 80 plus efficiency preferred) Input Voltage: 220–240V AC, 50 HzSurge protection recommended11. Software (Camera System Integration) Pre-installed software for:CCTV / IP Camera viewing Recording and playback functionality Network camera integration supportCompatibility with standard surveillance systems (ONVIF preferred) with Originmal window 11 professional and antivirus for 2 years validity.12. Display Size 24” LED Resolution: Full HD (1920×1080) Ports: HDMI/VGA14. Compliance and Standards CE / FCC / BIS certified Energy-efficient compliant15. Additional Requirements Preloaded drivers and utilitiesSystem fully assembled, tested, and commissioned All cables and accessories included )Make: HP/ Dell` |
| 564 | Supply,installation, testing and commissioning of cubical type dust and vermine proof H.T. Metering panel free for standing floor mounting suitable for 11 KV 3 Phase supply made out of 14 gauge MS sheet with channel from base frame painted with stoving synethic light gray enameled paint suitable for operation on 11 KV 3 Phase four wire 50 cycle systems effectively earthed system and consisting of the followings:-i) 3 nos 11 KV C.T of required capacity of stova burden class o.5 of approved make by HVPN.ii) ONE No PT 11KV/110 volts 3 phase oil cooled 10 va class 0.5 of make as approved make byHVPN.iii) 2 NOS cable holes for incoming and outgoing 11KV cable.iv) Wiring and terminal blockv) THE panel will be complete with all internal wiring, inter connection of VT and HT, compound filling of cable and boxes, HT cable connections etc complete in all respect as approved by UHBVN authorities including the cost of security for H.T. Meter, testing fee of CTs, PT and other equipment`s as required by UHBVN authorities. |
| 565 | SITC of Water cooler 150Ltr. Cooling capacity and 150 Ltr. Storage capacity water cooler with 2 No. taps, Locking arrangement with 4KVA 170/270 V rating coper wound stabilizer Make: as per approved HPHC brand list (NS). |
| 566 | SITC of LED Flood Light 200 Watt operation on single phase AC Supply including inbuilt LED Driver with constant current. lumens = 100 lumens /watt , 6500 K Cool white colour, input voltage 220-240,frequancy 50 Hz, power factor = 0.85, Protection IP20 for indoor and IP = 65 for outdoor fixtures. Made up of Pressure die cast aluminium powder coated. Temprature range -10 degree to plus 45°,THD (10%, surge protection = 2.5 KV, burning hours = 40000 Hours, BIS Certified Complete in all respect. Make as per HPHC approved Brand List |
| 567 | SITC of 50 LPH (50 ltr per hour) capacity RO, Commercial type including Pre-filters, RO plus UV plus UF plus TDS complete in all respect with making necessary connections, the water should be filtered with PH value (range 6.5 to maximum 8.0) and work shall be done as per entire satisfaction of Engineer-in-charge |
| 568 | Supply of 70W LED street light luminaire made of pressure die-cast aluminium housing with toughened glass and high-power LEDs. The luminaire shall have a minimum luminous efficacy of 100 lm/W and a service life of 50,000 hours. The correlated color temperature (CCT) shall be 6500K. The fixture shall have protection rating of IP66 and impact resistance of IK10. The power factor shall be = 0.95 and total harmonic distortion (THD) shall be less than 10%. The luminaire shall be provided with surge protection of minimum 10 kV and suitable for operating in ambient temperature range of -10°C to plus 55°C. Make- As per HPHC Brand list. |
| 569 | SITC of Main LT Panel ( TTA Panel as per IEC-61439-1and2) complete in all respect., INCOMING SUPPLY- 1 and 2 (EB and DG) 21 630A, 4P, EDO 50KA ACB with Microprosser Based O/L,S/C and Earth Faullt Release- 2 No.2 Interlocking System 2 No. .3 Shunt Release 2 No. .4 Under Voltage Release 240V AC 2 No. .5 Aux. Contact Block 2 No. .6 CTs 600/1A For Metering 6 Nos7 Multifunction Meter 2 No.8 Aux. Contactor 2NO plus 2NC Block 2 No. .9 Breaker Control Switch (TNC Switch) 2 No .10 Indication Lamp Red 4 Nos. .11 Indication Lamp Yellow 2 No .12 Indication Lamp Blue. 2 No .13 Indication Lamp Green. 2 No .14 Indication Lamp Amber. 2 No .15 Control MCB 6A SP.10KA `C` Curve. 12 Nos. .16 Neutral Link 2 No. .17 CT Shorting Link 6 Nos. .18 Control Terminals 8 Nos. .19 Exhaust Fan 2 No. Reputed20 Panel Light with Limit Switch 4 Nos. Reputed BUS COUPLER - 11 630A, 4P, EDO 50KA ACB with Microprosser Based O/L,S/C and Earth Faullt Release- 1 No. .2 Interlocking System 1 No. .3 Shunt Release 1 No. .4 Under Voltage Release 240V AC 1 No. .5 Aux. Contact Block 1 No. .6 Aux. Contactor 2NO plus 2NC Block 1 No. .7 Breaker Control Switch (TNC Switch) 1 No .8 Indication Lamp Red 1 Nos. .9 Indication Lamp Green. 1 Nos. .10 Indication Lamp Amber. 1 Nos. .11 Control MCB 6A SP.10KA `C` Curve. 4 Nos. .12 Neutral Link 1 Nos. .13 Control Terminals 4 Nos. .OUT GOING FEEDERS :- BUS SECTION-1 250A FP MCCB Feeder -: 11 250A FP 36KA MCCB with TM Based Release having O/L,S/C protections 1 Nos. .2 ROM For 250A MCCB 1 Nos. .3 Spreader Link For 250A FP MCCB 2 Nos. . 400A FP MCCB Feeder -: 21 400A FP 36KA MCCB with TM Based Release having O/L,S/C protections 2 Nos. .2 ROM For 400A MCCB 2 Nos. .3 Spreader Link For 400A FP MCCB 4 Nos. . 100A FP MCCB Feeder -: 11 100A FP 36KA MCCB with TM Based Release having O/L,S/C protections 1 Nos. .2 ROM For 100A MCCB 1 Nos. .3 Spreader Link For 100A FP MCCB 2 Nos. . Make Tricolite, Unipan ,Vridavan, ISPL (international switch gear pvt limited) |
| 570 | Supply, Installation, Testing and Commissioning (SITC) of 200 kVA , 3 Phase Diesel Generator Set consisting of a liquid-cooled, turbocharged diesel engine conforming to latest CPCB IV plus emission norms, developing required BHP at 1500 RPM as per OEM design, directly coupled to a brushless alternator of 200 kVA capacity, rated at 415 Volts, 50 Hz, 0.8 power factor.The alternatorl be self-excited, self-regulated with AVR, having Class H insulation and suitable for continuous duty, and capable of withstanding 110% overload for 1 hour in 12 hours operation. The engine and alternator shall be mounted on a common heavy-duty fabricated steel base frame, properly aligned and fitted with anti-vibration mountings (AVMs).The DG set shall include:Electronic governor for precise speed control. Inbuilt MS fuel tank with level indicator.Residential/industrial grade acoustic enclosure made of CRCA sheet steel with powder coating, complying with CPCB IV plus noise norms (75 dBA @ 1 m)Exhaust system with residential silenceStarting system: 12V/24V DC electric start with battery set (2 Nos. for 24V system preferred) and chargerStandard AMF (Automatic Mains Failure) control panel with microprocessor-based controller, protections for overload, short circuit, low oil pressure, high engine temperature, under/over voltage, frequency, etc.Manual bypass/operation facility complete in all respect as per entire satisfaction of Engineer-in-Charge |
| 571 | SITC of APFCR Panel-120 KVAR (TTA Panel as per IEC-61439-1and2) complete in all respect., INCOMING SUPPLY- 11 250A TP 36KA MCCB with TM Based Release having O/L,S/C protections 1 Nos. .2 ROM For 250A MCCB 1 Nos. .3 Spreader Link For 250A TP MCCB 2 Nos. .4 Amp. Meter 630A Digital Type plus ASS 1 No. Sec./Elm./Sch5 Volt Meter 0-500V Digital Type plus VSS 1 No. Sec./Elm./Sch6 8Step APFC Relay 1 No. Epcos/BCH7 Indication Lamp Red 1 Nos. .8 Indication Lamp Yellow 1 Nos. .9 Indication Lamp Blue 1 Nos. .10 Control MCB 6A SP.10KA `C` Curve. 4 Nos. .11 CTs 630/5A For Metering and APFCR 3 Nos. NewTek/Reputed12 Selector Switch 1 No. .13 CT Shorting Link 3 Nos..14 Control Terminals 4 Nos..15 Neutral Link 1 No..16 Exhaust Fan 1 Nos. Reputed17 Panel Light CFL 9W with Limit Switch 2 Nos. Reputed.11 Control MCB 6A SP.10KA `C` Curve. 6 Nos. .12 25Kvar Harmonic Filters-7% 440 V 2 Nos..13 25x1Kvar,525 V Capacitor Super Heavy Duty Type 2 Nos.14 Control Terminals 2 Nos..15 Neutral Link 2 Nos.. 20kvar Capactior Feeder 21 MCB 50A TP.10KA `C` Curve. 2 Nos. .2 50A TP Power Contactor 2 Nos. .3 Selector Switch 2 Nos.4 Indication Lamp On 2 Nos.5 Indication Lamp Off 2 Nos.6 Indication Lamp Trip 2 Nos.7 Start Push Button 2 Nos. .8 Stop Push Button 2 Nos. .9 Push Button NO Block 2 Nos. .10 Push Button NC Block 2 Nos. .11 Control MCB 6A SP.10KA `C` Curve. 6 Nos. .12 20Kvar Harmonic Filters-7% 440 V 2 Nos..13 20x1Kvar,525 V Capacitor Super Heavy Duty Type 2 Nos.14 Control Terminals 2 Nos..15 Neutral Link 2 Nos.. 10kvar Capactior Feeder 21 MCB 50A TP.10KA `C` Curve. 2 Nos. .2 25A TP Power Contactor 2 Nos. .3 Selector Switch 2 Nos. .4 Indication Lamp On 2 Nos. .5 Indication Lamp Off 2 Nos. .6 Indication Lamp Trip 2 Nos. .7 Start Push Button 2 Nos. .8 Stop Push Button 2 Nos. .9 Push Button NO Block 2 Nos. .10 Push Button NC Block 2 Nos. .11 Control MCB 6A SP.10KA `C` Curve. 4 No. .12 5Kvar Harmonic Filters-7% 440 V 3 Nos..13 5x1Kvar,525 V Capacitor Super Heavy Duty Type 1 No.14 Control Terminals 4 Nos..15 Neutral Link 1 No.. Panel (2375X1300X1200mm Appx.)1 Powder Coated Enclosure made out of TATA make CRCA sheet having 2 mm for load bearing surfaces and 1.6 mm for non load bearing surfaces ,duly 7 Tank processsed powder coated having 3902 Aluminium Bus Bar 630A TPN Electrolite grade E91 having cross section 1X80X12 mm for Phase, 1x40x6 mm for Neutral48.4 Hind./Cent.3 Complete Wiring 14 Hardware, Accessories etc. 15 Labour 1Make Tricolite,Unipan,Vridavan,ISPL ( (international switch gear pvt limited) |
| 572 | SITC of ESE TYPE LIGHTNING ARRESTERESE lightning air terminal with the below technical parameters.• Stainless Steel material(304L)–suitable for corrosive environments• ?T=60 micro seconds• METU lab tested asper NFC17-102(2011) standard• CPRI tested for70KA (8/20microsec)• Lightning current = 100KA(10/350microsec) tested• Protection radius = 107mtrs.(Level-IV/ VeryHigh)including 1no. Lightening Strike Counter, 3 nos 17.2 mm dia 3 meter long copperbonded solid electrode with 25 kg Chemical with tir-port and RCC chamber, 30 mtr 70 SQ MM SINGLE CORE PURE COPPER CABLE WITH THIMBLE complete in all respect into the entire satisfaction of Engine.Make- OBO Bettermann , Axis Electricals, nVent Erico, Alltec, Franklin France, and Helita. |
| 573 | SITC of APFCR Panel-120 KVAR (TTA Panel as per IEC-61439-1and2) complete in all respect., INCOMING SUPPLY- 11 250A TP 36KA MCCB with TM Based Release having O/L,S/C protections 1 Nos. .2 ROM For 250A MCCB 1 Nos. .3 Spreader Link For 250A TP MCCB 2 Nos. .4 Amp. Meter 630A Digital Type plus ASS 1 No. Sec./Elm./Sch5 Volt Meter 0-500V Digital Type plus VSS 1 No. Sec./Elm./Sch6 8Step APFC Relay 1 No. Epcos/BCH7 Indication Lamp Red 1 Nos. .8 Indication Lamp Yellow 1 Nos. .9 Indication Lamp Blue 1 Nos. .10 Control MCB 6A SP.10KA `C` Curve. 4 Nos. .11 CTs 630/5A For Metering and APFCR 3 Nos. NewTek/Reputed12 Selector Switch 1 No. .13 CT Shorting Link 3 Nos..14 Control Terminals 4 Nos..15 Neutral Link 1 No..16 Exhaust Fan 1 Nos. Reputed17 Panel Light CFL 9W with Limit Switch 2 Nos. Reputed.11 Control MCB 6A SP.10KA `C` Curve. 6 Nos. .12 25Kvar Harmonic Filters-7% 440 V 2 Nos..13 25x1Kvar,525 V Capacitor Super Heavy Duty Type 2 Nos.14 Control Terminals 2 Nos..15 Neutral Link 2 Nos.. 20kvar Capactior Feeder 21 MCB 50A TP.10KA `C` Curve. 2 Nos. .2 50A TP Power Contactor 2 Nos. .3 Selector Switch 2 Nos.4 Indication Lamp On 2 Nos.5 Indication Lamp Off 2 Nos.6 Indication Lamp Trip 2 Nos.7 Start Push Button 2 Nos. .8 Stop Push Button 2 Nos. .9 Push Button NO Block 2 Nos. .10 Push Button NC Block 2 Nos. .11 Control MCB 6A SP.10KA `C` Curve. 6 Nos. .12 20Kvar Harmonic Filters-7% 440 V 2 Nos..13 20x1Kvar,525 V Capacitor Super Heavy Duty Type 2 Nos.14 Control Terminals 2 Nos..15 Neutral Link 2 Nos.. 10kvar Capactior Feeder 21 MCB 50A TP.10KA `C` Curve. 2 Nos. .2 25A TP Power Contactor 2 Nos. .3 Selector Switch 2 Nos. .4 Indication Lamp On 2 Nos. .5 Indication Lamp Off 2 Nos. .6 Indication Lamp Trip 2 Nos. .7 Start Push Button 2 Nos. .8 Stop Push Button 2 Nos. .9 Push Button NO Block 2 Nos. .10 Push Button NC Block 2 Nos. .11 Control MCB 6A SP.10KA `C` Curve. 4 No. .12 5Kvar Harmonic Filters-7% 440 V 3 Nos..13 5x1Kvar,525 V Capacitor Super Heavy Duty Type 1 No.14 Control Terminals 4 Nos..15 Neutral Link 1 No.. Panel (2375X1300X1200mm Appx.)1 Powder Coated Enclosure made out of TATA make CRCA sheet having 2 mm for load bearing surfaces and 1.6 mm for non load bearing surfaces ,duly 7 Tank processsed powder coated having 3902 Aluminium Bus Bar 630A TPN Electrolite grade E91 having cross section 1X80X12 mm for Phase, 1x40x6 mm for Neutral48.4 Hind./Cent.3 Complete Wiring 14 Hardware, Accessories etc. 15 Labour 1Make Tricolite,Unipan,Vridavan,ISPL ( (international switch gear pvt limited) |
| 574 | OUTDOOR UNIT - Supplying, Installation, Testing and Commissioning of Modular type Variable Refrigerant Flow/Variable Refrigerant Volume air cooled Outdoor units suitable for cooling/heating having 100% hermetically sealed inverter type twin Rotary/Scroll Compressor(s), minimum two compressors (with individual separate PCB) for above 14HP modules, microprocessor based Controller, top discharge type condensing unit(s), with R-410-A Refrigerant or equivalent, vibration Isolators with suitable foundation etc. complete as required. To have better efficiency condenser fan shall be capable to operate at different speed with respect to load. The unit shall deliver the rated capacity and in confirmation as per IS 18728:2024 and CPWD Specifications and work even at 50°C ambient temperature without tripping. The system shall be able to deliver 100% of the rated capacity upto 39°C. The unit shall be suitable to work on 400V plus /- 10%, 3 Phase, 50Hz AC power supply and BMS compatible. The unit shall be filled with first charge of the refrigerant and ready for use as required. The condenser should be coated with a hydrophilic film to prevent water accumulation on the surface of the heat exchanger, enhance water dispersion, and reduce the risk of degradation, thereby improving overall performance and durability. The Indian Seasonal Energy Efficiency Ratio (ISEER) of the unit shall be as per Energy Conservation and Sustainable Building Code (ECSBC) 2024 as below and complete as per CPWD specification, connections, inter connections etc. as required. (For capacity (40 kWr ISEER 7.4, Capacity ) 40 and (70 ISEER 7.5, Capacity ) 70 ISEER 7.6 for Super ECSBC Building)For Cooling or Heating or Both (DSR 31.3.3) 14 HP to 22 HP |
| 575 | Supplying, Installation, Testing and Commissioning of following minimum capacity 4 way Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration Isolation, Corded remote control etc., suitable for operation on single phase 230 V ± 10%, 50Hz AC supply, complete, as required. The Indoor units must shut down upon receiving a singal from the BMS System/Fire Singnals. The system shall be capable to adjust air flow as per room requirement in auto mode. The cooling capacity of indoor unit will be at air inlet conditions of 27 0C DB and 19 0C WB temperature. (Make will be same as of Outdoor) (DSR 31.4.3) 1.2 TR |
| 576 | Supplying, Installation, Testing and Commissioning of following minimum capacity 4 way Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration Isolation, Corded remote control etc., suitable for operation on single phase 230 V ± 10%, 50Hz AC supply, complete, as required. The Indoor units must shut down upon receiving a singal from the BMS System/Fire Singnals. The system shall be capable to adjust air flow as per room requirement in auto mode. The cooling capacity of indoor unit will be at air inlet conditions of 27 0C DB and 19 0C WB temperature. (Make will be same as of Outdoor) (DSR 31.4.4) 1.6 TR |
| 577 | Supplying, Installation, Testing and Commissioning of following minimum capacity 4 way Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration Isolation, Corded remote control etc., suitable for operation on single phase 230 V ± 10%, 50Hz AC supply, complete, as required. The Indoor units must shut down upon receiving a singal from the BMS System/Fire Singnals. The system shall be capable to adjust air flow as per room requirement in auto mode. The cooling capacity of indoor unit will be at air inlet conditions of 27 0C DB and 19 0C WB temperature. (Make will be same as of Outdoor) (DSR 31.4.5) 2.0 TR |
| 578 | Supplying, Installation, Testing and Commissioning of following minimum capacity 4 way Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration Isolation, Corded remote control etc., suitable for operation on single phase 230 V ± 10%, 50Hz AC supply, complete, as required. The Indoor units must shut down upon receiving a singal from the BMS System/Fire Singnals. The system shall be capable to adjust air flow as per room requirement in auto mode. The cooling capacity of indoor unit will be at air inlet conditions of 27 0C DB and 19 0C WB temperature. (Make will be same as of Outdoor) (DSR 31.4.7) 2.6 TR |
| 579 | Supplying, Installation, Testing and Commissioning of following minimum capacity High wall type Indoor unit equipped with and comfort washable synthetic media pre- filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, outer cabinet, cord less remote control, drain pan, necessary accessories etc., suitable for operation on 230 V ± 10%, 50 Hz, single phase AC supply, complete as required. The Indoor units must shut down upon receiving a singal from the BMS System/Fire Singnals. The system shall be capable to adjust air flow as per room requirement automatically. The cooling capacity of indoor unit will be at air inlet conditions of 27 0C DB and 19 0C WB temperature. (Make will be same as of Outdoor) DSR 31.8.1 - 0.6 TR |
| 580 | Supplying, Installation, Testing and Commissioning of following minimum capacity High wall type Indoor unit equipped with and comfort washable synthetic media pre- filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, outer cabinet, cord less remote control, drain pan, necessary accessories etc., suitable for operation on 230 V ± 10%, 50 Hz, single phase AC supply, complete as required. The Indoor units must shut down upon receiving a singal from the BMS System/Fire Singnals. The system shall be capable to adjust air flow as per room requirement automatically. The cooling capacity of indoor unit will be at air inlet conditions of 27 0C DB and 19 0C WB temperature. (Make will be same as of Outdoor) DSR 31.8.2 - 0.8 TR |
| 581 | Supplying, Installation, Testing and Commissioning of following minimum capacity High wall type Indoor unit equipped with and comfort washable synthetic media pre- filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, outer cabinet, cord less remote control, drain pan, necessary accessories etc., suitable for operation on 230 V ± 10%, 50 Hz, single phase AC supply, complete as required. The Indoor units must shut down upon receiving a singal from the BMS System/Fire Singnals. The system shall be capable to adjust air flow as per room requirement automatically. The cooling capacity of indoor unit will be at air inlet conditions of 27 0C DB and 19 0C WB temperature. (Make will be same as of Outdoor) DSR 31.8.3 - 1.0 TR |
| 582 | Supplying, Installation, Testing and Commissioning of following minimum capacity and external static pressure VRF/VRV ceiling mounted mid static ductable type Indoor unit equipped with washable synthetic media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, corded remote control, outer cabinet, vibration Isolators, drain pan, drain pump, other necessary supports etc., suitable for operation on single phase AC supply 230 V ± 10%, 50 Hz complete as required. The Indoor units must shut down upon receiving a singal from the BMS System/Fire Singnals. The cooling capacity of indoor unit will be at air inlet conditions of 27 0C DB and 19 0C WB temperature. (Make will be same as of Outdoor)DSR 31.11.9. - 4.6 TR |
| 583 | Supplying, Installation, Testing and Commissioning of following minimum capacity and external static pressure VRF/VRV ceiling mounted high ductable type Indoor unit equipped with washable synthetic media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, corded remote control, outer cabinet, vibration Isolators, drain pan, drain pump, other necessary supports etc., suitable for operation on single phase AC supply 230 V ± 10%, 50 Hz complete as required. The Indoor units must shut down upon receiving a singal from the BMS System/Fire Singnals. The cooling capacity of indoor unit will be at air inlet conditions of 27 0CDB and 19 0C WB temperature. (Make will be same as of Outdoor) DSR 31.12.3 - 6.6 TR |
| 584 | Supplying, Installation, Testing and Commissioning of following minimum capacity and external static pressure VRF/VRV ceiling mounted high ductable type Indoor unit equipped with washable synthetic media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, corded remote control, outer cabinet, vibration Isolators, drain pan, drain pump, other necessary supports etc., suitable for operation on single phase AC supply 230 V ± 10%, 50 Hz complete as required. The Indoor units must shut down upon receiving a singal from the BMS System/Fire Singnals. The cooling capacity of indoor unit will be at air inlet conditions of 27 0CDB and 19 0C WB temperature. (Make will be same as of outdoor ) DSR 31.12.4. - 8.0 TR |
| 585 | Supplying and fixing of following thickness duly laminated aluminum foil of mat finish closed cell Nitrile rubber (Class `O`) insulation on existing duct after applying suitable adhesive for Nitrile rubber. The joints shall be sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required. above. Valves should have pressure rating of 25 Bar minimum. (DSR 16.23.1.) 19mm |
| 586 | Supply and fixing of Acoustic lining of supply air duct and plenum with 25 mm thick resin bonded glass wool having density of 32 kg/m³, with 25 mm X 25 mm GI section of 1.25 mm thick, at 600 mm centre to centre covered with Reinforced Plastic tissue paper and0.5 mm thick perforated aluminum sheet fixed to inside surface of ducts with cadmium plated nuts, bolts, stick pins, CPRX compound etc. complete as required and as per specifications. (DSR 16.21) |
| 587 | Supplying, Fixing, testing and commissioning of fire dampers in supply air duct/main branch and return air path as and where required of required sizes i/c control wiring, the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal complete as required and as per specifications. (DSR 16.20.2.) Actuator |
| 588 | Supplying, Fixing ,testing and commissioning of fire dampers in supply air duct/main branch and return air path as and where required of required sizes i/c control wiring, the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal complete as required and as per specifications. (DSR 16.20.1) Fire Damper |
| 589 | Supplying, fixing testing commissioning of Return air diffusers of powder coated aluminium without volume control dampers with anti smudge ring and removable core. (DSR 16.18) |
| 590 | Supplying, fixing testing commissioning of supply air diffusers of powder coated aluminium with aluminium volume control dampers with anti smudge ring and removable core. (DSR 16.17) |
| 591 | Supplying and fixing of powder coated extruded aluminium Return Air Grills with louvers but without volume control dampers complete as required. (DSR 16.16) |
| 592 | Supplying and fixing of powder coated extruded aluminium Supply Air Grills with aluminium volume control dampers as per specifications (DSR 16.15) |
| 593 | Supply, installation, testing and commissioning of GI volume control sqm duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc, as per specifications. (DSR 16.13) |
| 594 | Supply, Installation, testing and commissioning of following Ceiling suspended TFA units with cordless/corded remote controller. Fully Factory assembled, wired and tested TFA Units as per specifications and as required to make the system complete. 2) 936 CFM (TFA) (8.0 HP) |
| 595 | Supply, Installation testing and commissioning of Corded remote controls |
| 596 | Supply Installation, testing, commissioning of supply and return Y-joints sets of required size for refrigerant piping as per manufacturer standards. |
| 597 | Supply, Installation, testing and commissioning of Interconnecting refrigerant pipe work with (19 mm / 13mm thick) closed cell elastomeric nitrile rubber tubular insulation with GC cloth between each set of indoor and outdoor units as per specifications, all piping inside the room shall be properly supported with MS hanger and all external piping covered with Star bond shall run in covered cable tray Outside with Star bond as per specifications. Dia 6.4mm OD 13mm thick insulation |
| 598 | Supply, Installation, testing and commissioning of Interconnecting refrigerant pipe work with (19 mm / 13mm thick) closed cell elastomeric nitrile rubber tubular insulation with GC cloth between each set of indoor and outdoor units as per specifications, all piping inside the room shall be properly supported with MS hanger and all external piping covered with Star bond shall run in covered cable tray Outside with Star bond as per specifications. Dia 9.5 mm OD 13mm thick insulation |
| 599 | Supply, Installation, testing and commissioning of Interconnecting refrigerant pipe work with (19 mm / 13mm thick) closed cell elastomeric nitrile rubber tubular insulation with GC cloth between each set of indoor and outdoor units as per specifications, all piping inside the room shall be properly supported with MS hanger and all external piping covered with Star bond shall run in covered cable tray Outside with Star bond as per specifications. Dia 12.7 mm OD 13mm thick insulation |
| 600 | Supply, Installation, testing and commissioning of Interconnecting refrigerant pipe work with (19 mm / 13mm thick) closed cell elastomeric nitrile rubber tubular insulation with GC cloth between each set of indoor and outdoor units as per specifications, all piping inside the room shall be properly supported with MS hanger and all external piping covered with Star bond shall run in covered cable tray Outside with Star bond as per specifications. Dia 15.9 mm OD 13mm thick insulation |
| 601 | Supply, Installation, testing and commissioning of Interconnecting refrigerant pipe work with (19 mm / 13mm thick) closed cell elastomeric nitrile rubber tubular insulation with GC cloth between each set of indoor and outdoor units as per specifications, all piping inside the room shall be properly supported with MS hanger and all external piping covered with Star bond shall run in covered cable tray Outside with Star bond as per specifications. Dia 19.1 mm OD 19mm thick insulation |
| 602 | Supply, Installation, testing and commissioning of Interconnecting refrigerant pipe work with (19 mm / 13mm thick) closed cell elastomeric nitrile rubber tubular insulation with GC cloth between each set of indoor and outdoor units as per specifications, all piping inside the room shall be properly supported with MS hanger and all external piping covered with Star bond shall run in covered cable tray Outside with Star bond as per specifications. Dia 22.2 mm OD 19m thick insulation |
| 603 | Supply, Installation, testing and commissioning of Interconnecting refrigerant pipe work with (19 mm / 13mm thick) closed cell elastomeric nitrile rubber tubular insulation with GC cloth between each set of indoor and outdoor units as per specifications, all piping inside the room shall be properly supported with MS hanger and all external piping covered with Star bond shall run in covered cable tray Outside with Star bond as per specifications. Dia 25.2 mm OD 19mm thick insulation |
| 604 | Supply, Installation, testing and commissioning of Interconnecting refrigerant pipe work with (19 mm / 13mm thick) closed cell elastomeric nitrile rubber tubular insulation with GC cloth between each set of indoor and outdoor units as per specifications, all piping inside the room shall be properly supported with MS hanger and all external piping covered with Star bond shall run in covered cable tray Outside with Star bond as per specifications. Dia 28.6 mm OD 19mm thick insulation |
| 605 | Supply, Installation, testing and commissioning of Interconnecting refrigerant pipe work with (19 mm / 13mm thick) closed cell elastomeric nitrile rubber tubular insulation with GC cloth between each set of indoor and outdoor units as per specifications, all piping inside the room shall be properly supported with MS hanger and all external piping covered with Star bond shall run in covered cable tray Outside with Star bond as per specifications. Dia 31.8 mm OD 19mm thick insulation |
| 606 | Supply, Installation, testing and commissioning of Interconnecting refrigerant pipe work with (19 mm / 13mm thick) closed cell elastomeric nitrile rubber tubular insulation with GC cloth between each set of indoor and outdoor units as per specifications, all piping inside the room shall be properly supported with MS hanger and all external piping covered with Star bond shall run in covered cable tray Outside with Star bond as per specifications. Dia 34.9 mm OD 19mm thick insulation |
| 607 | Supply, Installation, testing and commissioning of Interconnecting refrigerant pipe work with (19 mm / 13mm thick) closed cell elastomeric nitrile rubber tubular insulation with GC cloth between each set of indoor and outdoor units as per specifications, all piping inside the room shall be properly supported with MS hanger and all external piping covered with Star bond shall run in covered cable tray Outside with Star bond as per specifications. Dia 41.3 mm OD 19 mm thick insulation |
| 608 | Providing and fixing in position the following PVC ( Min 3 mm thick) Heavy duty pipes cut to required lengths and installed with all screwed joints with the necessary elbows, tees and reducers etc duly insulated with 6 mm thick insulations per specifications. 40 mm Dia Pipes |
| 609 | Providing and fixing in position the following PVC ( Min 3 mm thick) Heavy duty pipes cut to required lengths and installed with all screwed joints with the necessary elbows, tees and reducers etc duly insulated with 6 mm thick insulations per specifications. 32mm dia pipes |
| 610 | Providing and fixing in position the following PVC ( Min 3 mm thick) Heavy duty pipes cut to required lengths and installed with all screwed joints with the necessary elbows, tees and reducers etc duly insulated with 6 mm thick insulations per specifications. 25mm dia |
| 611 | Supply, Installation, Testing and Balancing of Powder coated extruded aluminum construction toilet exhaust valve as per approved drawings and specifications. |
| 612 | Supply, fabrication, installation and testing the flexible connections constructed of fire resistance flexible double canvas sleeve as per the approved shop drawings. |
| 613 | Supply, Installation, Testing and commissioning of exhaust air fan suitable for Inline mounting comprising of forward curved centrifugal blower complete with induction motor, metal clad MCB, canvas connection all compete as required. Motor shall be suitable for single phase, 230 volts, 50Hz AC. supply as per specifications of following capacities: Noise level should not exceed 65dB(A)at 3 meter in room condition. 450 cfm capacity with10 mm static pressure CIRCULAR |
| 614 | Supply, installation, testing and commissioning of silent ceiling mounted cassette Exhaust fan for toilet exhaust 150 mm |
| 615 | Providing and fixing in position the following PVC ( Min 3 mm thick) Heavy duty pipes cut to required lengths and all screwed joints with the necessary elbows, tees and reducers etc as per specifications. Pipe dia in mm (3mm thick) 110 mm |
| 616 | VRV Panel - Design, fabrication, supply, installation, testing and commissioning of panels fabricated out of 2mm thick for structural members and 1.6mm thick for door and covers CRCA sheet in cubicle compartmentalize free standing floor mounted/ wall mounted powder coated with reinforcement wherever necessary. Cable gland plates shall be provided on top and bottom. Panels have 2 Nos. earthing terminals. Panels shall be suitable for 415V, 3-phase, 4-wire, 50Hz supply system lifting hooks shall also be provided in case of large panels. Degree of ingress protection shall be IP42. as per followings-ODU Power Supply isolator Panel (Terrace Floor)Incomer (2 No.):200 A, TPN MCCB (35 KA) with adjustable O/L fix short circuit, 200 Amps TPN Aluminium busbars, colour coded with heat shrinkable insulation sleeves, Volt meter /Ammeter/Indication Lamps, Outgoings - 8 Nos 63A TPN MCCB for VRV ODU and 2 Nos 63A MCB Spare complete in all respect. |
| 617 | Supplying, installation, testing and commissioning of control cabling with insulated PVC sheathed wire/cable as per IS-7098 (Part-1) of following sizes including terminations on suitable cable trays / uPVC pipe with supports, as required including connections on both sides as per specifications and as required.2 core x 1.5 sq. mm. |
| 618 | Supplying and fixing 2000mm x 900mm x 12 mm thick checkered rubber matting conforming to IS- 5424-1969 complete etc. as required. Please Enable Macros to View BoQ information |
| 619 | Supplying and fixing 2000mm x 900mm x 12 mm thick checkered rubber matting conforming to IS- 5424-1969 complete etc. as required. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy