| 1 | Point wiring for switch controlled primary light /Fan /exhaust fan points with 3x1.5 sq mm (P+N+E) FRLS PVC insulated 660/1100 volt grade flexible stranded copper conductor wires of Polycab/ Finolex/ APAR /RR Kabels /Grandlay/ eq make to be approved by EIC, to be laid in existing recessed or surface conduitng system and incl the cost of supplying and fixing modular grid plate mounted flush mounted 240 volts 6 amp control switch with modular cover plate of Schneider /ABB /L&T /Legrand /Simens / eq make to be approved by EIC , complete as per specification and as required to be provided nd fitted on GI boxes .The Job includes providing and laying of circuit wiring with 3 x 1.5 Sq.mm PVC Insulated multistranded copper to be laid through pvc conduit from DB to first switch in sub circuit complete job excluding cost of conduits .(Separate wiring for normal and invertor supply is to be provided and no extra circuit wiring shall be paid what so ever reason or length) Complete as required .The job further includes providing and fixing of lighting deep Junction Boxes /Fan Deep Boxes made of factory fabricated sheet steel (Heavy guage) dully powder coated to be installed in slab for holding of lighting fixtures /ceiling fans(including cost of conduits with allied accessories) |
| 2 | Wiring for light power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface l recessed medium class PVC conduit (25 mm dia PVC Conduits including cutting of walls /floors with hydraulic cutters and refacing to original position by way of cement plastering /pop / paiting etc complete job ) including alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. of Polycab/ Finolex/ APAR /RR Kabels /Grandlay / eq make to be approved by EIC |
| 3 | Wiring for submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit (25 mm dia PVC Conduits for housing upto 4 Sq.mm & 32 mm above 6 Sq.mm wires including cutting of walls /floors with hydraulic cutters and refacing to original position by way of cement plastering /pop / paiting etc complete job ) as required. of Polycab/ Finolex/ UPAR /RR Kabels /Grandlays / eq make to be approved by EIC |
| 4 | 2 X 2.5 sq. mm +1 X 2.5 sq. mm earth wire |
| 5 | 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 6 | 2 X 10 sq. mm + 1 X 10 sq. mm earth wire |
| 7 | 2 X 16 sq. mm + 1 X10 sq. mm earth wire |
| 8 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing of 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. ( Anti bacteria series of Schneider /ABB /L&T /Legrand/ eq. make to be approved by EIC) |
| 9 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing of 2 No's of 3 pin 5/6 A modular socket outlet and 2 No's of 5/6 A modular switch, connections etc. as required. ( Anti backteria series of Simens /ABB /L&T /Legrand / eq. make to be approved by EIC) |
| 10 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.( Anti backteria series of Simens /ABB /L&T /Legrand / eq. make to be approved by EIC) |
| 11 | Supplying and fixing of 16 Amps Box type S-S Combine for invertor input and out put |
| 12 | Supply and fixing of 16 Amps 3-Pin Top of SSK /Eq.make |
| 13 | Supply, Installation, Testing and Commissioning of 1200 mm sweep , 3 nos. blades, 30 cm long down rod, , suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required (3 star rating ) . of Usha /Helonix /Crompton / Orient/ eq. make to be approved by EIC |
| 14 | Supply, Installation testing and commissioning of 250 mm sweep Exhaust Fans of Usha / Crompton Greaves / Havel's incl making of necessary connections and making of necessary space in walls / Windows as per site.The Job includes providing and fixing of shutter of suitable size backlite hylum sheet for fixing of exhaust fan of Usha /havels /Crompton / Helonix / eq. make to be approved by EIC |
| 15 | Supply, Installation, Testing and commissioning of 12 watt LED surface/recessed Down lighters having Aluminium Body ,minimum lumens 100 lm/w ,the luminaries housing should be crca /aluminium and the luminary optics shall have a high efficiency with transmittance ,average life of 50000 hrs operating temperature -10 C to + 45 C of Wipro/ Helonix /Philips /LT /Regent / eq. make to be approved by EIC make incl making of necessary Connections. ). The job further includes replacement warranty of fixture (if damaged /burnt out what so ever reason) for a period of one years reckoned from date of successful commissioning /handing over of site to intending department. |
| 16 | Supply ,Installation ,Testing and Commissioning of 1P 66, 50 Watt LED Flood Luminaries having Aluminium body of Wipro/ Helonix /Philips /LT /Regent / eq. make to be approved by EIC dully isi marked approvals LM79 issued by NABL accredited lab, LM80 issued by LED manufacturer, Type Test Certificate for luminaire as issued by NABL accredited lab, BIS certificate for LED Luminaire & Driver. Approved make Philips / Lighting techology / Trilux /wipro/ eq. make to be approved by EIC (to be approved before installation) |
| 17 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/lsolator) of Legrend / L&T / ABB /Simens /schinder / eq. make to be approved by EIC |
| 18 | 6 way (4 + 18), Double door |
| 19 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioninq etc. as required of legrand / ABB /Schneider /L&T /Simens / eq. make to be approved by EIC |
| 20 | Supplying and fixing of 40 Amps rating DP 240/415 volts (10KA) of Legrend /L&T /ABB /Simens /Schinder make dully isi marked complete with connections.of Legrand / ABB /Schneider /L&T /Simens / eq. make to be approved by EIC |
| 21 | Supplying and fixing of 63 Amps rating DP 240/415 volts (10KA) of Legrend /L&T /ABB /Simens /Schinder make dully isi marked complete with connections.of Legrand / ABB /Schneider /L&T /Simens / eq. make to be approved by EIC |
| 22 | Supplying and fixing of 100 Amps rating DP 240/415 volts (10KA) of Legrend /L&T /ABB /Simens /Schinder / eq. make to be approved by EIC dully isi marked complete with connections |
| 23 | Supply/ installation/testing and commissioning of Wall / floor mounted compartmentalized , 415 volts TPN MCCB Main Distribution panels ,fabricated out of sheet steel of 16 gauge dust protected, duly painted with powder coating ( not less than 80 microns ) incl earth terminal with all necessary accessories as required for panel (IP 54) with internal wiring of panel .The Panel is to provided and fitted with following adjustable type controlling /Protection switch gear devices (1) Normal Incoming (1A) 125 Amp DP MCB (10KA) of Legrend /Schinder /Simens / ABB / eq. make to be approved by EIC = 1 no (1B) 200 Amp PN Aluminium Bus bar = 1 Set ( Bus Bar shall be insulated with heat shrinkable sleeves and shall be colour coded. having minimum size 20 mm x 10 mm with spacing as per latest IE Standards) (1C) One No. (1 No.) digital multifunctional meter for measurement of voltage ,current and power etc , and one set of CT's of ratio 125 A/5A ,CL 1.0 ,15VA .(1D) 1 Set of phase indication lamps (2) Generator Incomer 63 Amp F.P Change over switch of Havels./HPL /Standard / eq. make to be approved by EIC = 1 no100 Amp TPN Bus bar Al Strips = 1 Set( Bus Bar shall be insulated with heat shrinkable sleeves and shall be colour coded. having minimum size 10 mm x 10 mm with spacing as per latest IE Standards) (1C) One No. (1 No.) digital multifunctional meter for measurement of voltage ,current and power etc , and one set of CT's of ratio 63 A/5A ,CL 1.0 ,15VA .(1D) 1 Set of phase indication lamps (3) Invertor Incommer 63 Amps DP MCB (10KA) of Legrend /Schinder /Simens / ABB / eq. make to be approved by EIC =1 No.100 Amp PN Bus bar Al Strips = 1 Set( Bus Bar shall be insulated with heat shrinkable sleeves and shall be colour coded. having minimum size 10 mm x 10 mm with spacing as per latest IE Standards) (1C) One No. (1 No.) digital multifunctional meter for measurement of voltage ,current and power etc and one set of CT's of ratio 63 A/5A ,CL 1.0 ,15VA .(1D) 1 Set of phase indication lamps (4) Outgoing .100 Amps Double Pole MCB (10 KA) of Legrend /Schinder /Simens / ABB / eq. make to be approved by EIC = 4 No63 Amps Double Pole MCB (10 KA)of Legrend /Schinder /Simens / ABB / eq. make to be approved by EIC = 4 No 40 Amps Double Pole MCB (10 KA)of Legrend /Schinder /Simens / ABB / eq. make to be approved by EIC =4 No The Panel manufacturing unit should be CPRI Registered with latest ammended IEC / IS 61439 and the Contractor has to submit the test certificate of main switch gear's and Drawing's of panel (Showing claerly dimensions of panel with spacing of switchgear as per IE Standards ) & is to approved by Department not less than the rank of SDO before manufacturing of panel. |
| 24 | Supply,Laying,Testing & Commissioning of 50 sq.mm 2- core armored Al Cable XLPE/ PVC Insulated and Steel sheathed of Havells/ Eq. make, including cost thimbles on input aswell as output sides dully crimped with hydraulic crimping tool incl making of necessary connections ,Including rolling of LT Colour coded types for main service line from LT pole |
| 25 | Earthing with G.l. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoall coke and salt as required.The job includes providing and fixing of main hole PVC Chamber with its cover complete job |
| 26 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. Please Enable Macros to View BoQ information |