| 1 | Dismantling AC (Corrugated, semi corrugated, etc) sheets in roof coverings complete all as specified and as directed |
| 2 | Dismantling plain or corrugated steel sheeting ,any gauge ,thickness incl Nainital or similar pattern roof covering, complete all as specified and directed |
| 3 | S&F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.5mm thick of an colour having tenstile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws complete all as specified and as directed. |
| 4 | S&F pre-painted galvalume aluminium zinc coating GI based Plain steel sheet 0.5mm thick of an colour having tenstile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws as specified and as directed |
| 5 | S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet to be used as crimp curve 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws, complete all as specified and directed |
| 6 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed |
| 7 | M&Lfor roof trusses (framed) trussed, purlins, crane gantaries, rails and fastening and heavy braket framing (beam, tee, angle, chanel or flat section) including distance peices etc conforming to Fe 410 W Gde E-250 complete all as specified and directed. |
| 8 | S&F Steel work in tubular trusses, pillars and purlins including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S 1161-1979 grade St.-240 complete all as specified and directed by Engr-in-Charge. |
| 9 | Material & Labour for providing and fixing stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement, complete all as specified and directed |
| 10 | M&L prepration of steel surfaces over 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of zinc chromate primer complete all as specified and directed |
| 11 | M&L for prepration of old painted steel surfaces over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed |
| 12 | Taking down eaves gutters and rainwater pipes( any size or pattern) , including all fittings, heads, shoes, bends , swan necks, etc, removal to store (measured overall as fixed along the centre line over fittings and accessories), complete all as specified and directed |
| 13 | S &F 150 mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall including bends complete all as specified and directed. |
| 14 | S &F 110 mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall, complete all as specified and directed. |
| 15 | S &F 75 mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall, complete all as specified and directed. |
| 16 | S&F of PVC (SWR) bends any radius 110mm bore complete all as specified and as directed |
| 17 | S&F of PVC (SWR) bends any radius 75mm bore complete all as specified and as directed |
| 18 | S&F for mild steel Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165, complete all as specified and directed |
| 19 | Dismantling wall and ceiling boards or insulation boards, any thickness, any description, including cover fillets complete all as specified and directed. Note:- The quoted unit rate shall be deemed to include the cost of scaffolding, all necessary arrangements, and safety measures for work at any building height. No additional payment shall be admissible on this account |
| 20 | S&F Anodised aluminium snap grid of size 600x600 mm frame work for false ceiling complete all as specified and as directed by Engr in Charge. |
| 21 | S&F of hangers 6 mm dia GI ( upto 1200 mm length ) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40x3 mm size 60mm long and expansion hold fasteners 12.5mm dia, 40mm long complete all as specified and directed. |
| 22 | S&F of 4 mm thick non asbestos cement plain building board fixed to aluminium grid frame work in ceiling complete all as specified and directed. Note:- The quoted unit rate shall be deemed to include the cost of scaffolding and all necessary arrangements for work at any building height. No additional payment shall be admissible on this account |
| 23 | S&F in repair 4 mm thick Non asbestos fibre cement building boards fixed or laid/ inserted to timber/ GI/ Aluminium framework with screws in ceiling flat or sloping, complete all as specified and directedNote:- The quoted unit rate shall be deemed to include the cost of scaffolding and all necessary arrangements for work at any building height. No additional payment shall be admissible on this account |
| 24 | Supply and fix, in repair 8 to 10mm thick Armstrong ceiling board of RH -90 false ceiling consisting of 600mm x 600mm insert existing frame work without disturbing the other false ceiling and making good existing frame with complete all as specified and directed by Engr-in-Charge.Note:- The quoted unit rate shall be deemed to include the cost of scaffolding, all necessary arrangements, and safety measures for work at building height up to 30.0 meter. No additional payment shall be admissible on this account |
| 25 | M & L for preparing asbestos & ceiling board surfaces and applying two coats of oil bound distemper over a coat of chalk whitening on plastered surfaces complete all as specified and directed. Note:- The quoted unit rate shall be deemed to include the cost of scaffolding, all necessary arrangements, and safety measures for work at any building height. No additional payment shall be admissible on this account. |
| 26 | Supply and fix, in repair PVC False ceiling consisting of 600 mm x 600 mm, 8-10mm thick prelaminated self design consisting of 600mm x 600mm insert existing frame work without disturbing the other false ceiling and making good existing frame with all as specified and directed by Engr-in-Charge.Note:- The quoted unit rate shall be deemed to include the cost of scaffolding, all necessary arrangements, and safety measures for work at building height up to 30.0 meter. No additional payment shall be admissible on this account |
| 27 | S&F in repair 12.5 mm thick square edge PVC Laminated Gypsum Tile of size 595x595 mm, made of Gypsum plasterboard, manufactured from natural gypsum as per IS 2095 part I and laminated with white 0.16mm thick fire retardant PVC film on the face side and 12 micron metalized polyester on the back side with all edges sealed with the face side PVC film which goes around and wraps the edges and is bonded to the edges and the back side metalized polyester film so as to make the tile a completely sealed unit in existing false ceiling frame work, complete all as directed by Engr-in-Charge |
| 28 | M&L for complete removal of existing water proofing treatment any description up to concrete surface of roof slab including cleaning, with wire brushing, watering, removal of debris upto 1500 m distance complete all as specified and directed Note :- Unit rate quoted shall also include for removal of PVC water storage tank wherever existing carefully and refixing at the same or other position after completion of roof repair work. No additional payment shall be admissible on this account. |
| 29 | Demolition of cement concrete (unreinforced) roof or chajja padding of any description and any position not otherwise specifically provided for complete all as specified and directed |
| 30 | M&L for providing, PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) as in roof / chajja padding for maintaining roof / chajja slope including mixed with WPC by weight of total cement as per manufacturers instructions, complete all as specified and as directed.Note : WPC shall be measured and paid separately |
| 31 | M&L for applying oil bound primer @ 0.40 Litre/Sqm manufactured by the same agency as that of APP with density of 0.87 to 0.89 Kg/Litre at 25 degree cesius on the prepared dry roof surface and provide and lay 4mm thick APP modifed water proofing membrane reinforced with non-wooven polyster matt with physical properties as given in particular specification. The laying shall got be done through authorized applicator of manufacturer as specified in particular specifications. Provide over the membrane finishing with two coats of solar reflective bituminous aluminium paint @ 0.10 Kg/sqm as prescribed by manufacturer of membrane including Ten years guarantee on prescribed form complete all as specification, manufacturers instructions and as directed by Engineer-in-Charge. |
| 32 | M&L for rendering 10mm thick cement plaster in CM 1:3 on roof top surface including mixed with WPC by weight of total cement as per manufacturers instructions, complete all as specified and as directed.Note : WPC shall be measured and paid separately |
| 33 | Supply only liquid integral water proofing compound, complete all as specified and directed |
| 34 | M&L for brickwork with subclass‘B’ bricks, straight or curved on plan exc. 6m mean radius built in cement mortar 1:6 including demolition of old brick work complete all as specified and directed. |
| 35 | Taking down cement plaster on brick walls or stone walls etc including raking out joint, hacking for key, scrubbing down with water etc including removing debries directed for a distance max upto 500m complete all as specified and directed. |
| 36 | M&L for rendering 15mm thick on fair faces of brick / concrete surfaces of walls in CM (1:4) mixed with WPC, finished even and smooth surfaces without using extra cement (WPC to be measured and paid separately) complete all as specified and directed. |
| 37 | M&L for rendering 10 mm thick on fair faces of brick work or concrete surfaces of walls in CM 1:6 finished even and smooth surfaces with out using extra cement complete all as specified and directed. |
| 38 | M&L for rendering 5 mm thick on ceilings in CM 1:3 and finishing the surface even and smooth surfaces without using extra cement complete all as specified and directed |
| 39 | M&L for three coats of white wash on newly plastered surfaces of ceilings including preparation of surface complete all as specified and directed |
| 40 | M & L for preparation of new or previously untreated plastered surfaces of walls and applying two coats of acrylic antifungal paint exterior grade paint over a coat of primer complete all as specified and as directed |
| 41 | M&L for applying 3mm thick wall care putty on new plastered surface and prepare the smooth surface with sand paper and applying two coats of oil bound distemper on walls complete all as specified and as directed by Engineer-in-Charge |
| 42 | Material & Labour for complete removal of existing treatment in wall and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and directed. |
| 43 | M & L for complete removal of existing treatment on old distempered surfaces of ceiling and applying two coats of distemper oil emulsion white or tined with application of putty wherever required on surface of ceiling complete all as specified and directed. |
| 44 | M&L for prepration of old plastered / decorated surfaces of walls and applying two coats of oil bound distemper on plastered / decorated wall surfaces including preparing surfaces with and incluidng applying of putty wherever required complete all as specified and directed. Please Enable Macros to View BoQ information |