| 1 | Taking down cement plaster up to any height including raking out joints, hacking for key and scrubbing down with water etc to receive plaster complete all as specified and directed. |
| 2 | M & L for rendering 15mm thick in cement mortar 1:6 on fair faces of brick or concrete surfaces and finishing the surfaces even and smooth without using extra cement complete all as specified and directed. |
| 3 | M&L for rendering 10mm thick in cement mortar 1:3 on fair faces of brick/concrete surface of ceiling and finishing the surfaces even and smooth without using extra cement complete all as specified and directed |
| 4 | M&L rendering 15mm in cement mortar 1:4 on fair faces of brick / concrete surfaces and finishing the surfaces even and smooth without using extra cement complete all as specified and directed. |
| 5 | M&L for preparation of newly plastered surfaces of ceiling/chajja or similar suspended work and applying three coats of white wash complete all as specified and directed. |
| 6 | M&L for preparation of newly plastered surfaces of walls and applying three coats of white wash complete all as specified and directed. |
| 7 | M&L for preparation of newly plastered surfaces of walls and applying two coats of oil bound distemper (white or tinted) over a coat of approved primer over one coat of cement based wall care putty complete all as specified and directed. |
| 8 | M&L preparation of newly plastered surfaces of walls including all cornices, pilasters etc and applying two coats of acrylic exterior emulsion apex paint (tint as approved by GE ) over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm complete all as specified and directed. |
| 9 | M&L for preparation of old decorated surfaces of walls (plastered or un plastered) including cornices, pilaster etc by brooming down with steel wire brushing, scrapping down, smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots etc including filling the depressions with cement based wall care putty and applying one coat of oil bound distemper complete all as specified and directed. |
| 10 | M&L for complete removal of existing treatment on walls and applying two coats of oil bound distemper over and including one coat of primer over one coat of cement based wall care putty complete all as specified and directed |
| 11 | M&L for preparation of old decorated surfaces of walls (plastered or un plastered) including cornices, pilaster etc by brooming down with steel wire brushing, scrapping down, smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots etc including filling the depressions with cement based wall care putty and applying one coat of white wash complete all as specified and directed. |
| 12 | M&L for complete removal of existing treatment on walls and applying two coats of white wash over and including filling the depressions with cement based wall care putty complete all as specified and directed |
| 13 | M&L for preparation of old decorated surfaces of ceiling/bottom of chajja and similar suspended work (plastered or un plastered) including cornices, plaster etc by brooming down with steel wire brushing, scrapping down, smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots etc including filling the depressions with cement based wall care putty and applying one coat of white wash complete all as specified and directed. |
| 14 | M&L for complete removal of existing treatment on ceiling/bottom of chajja and similar suspended work and applying two coats of white wash complete all as specified and directed |
| 15 | M&L for old painted surface of any description of brick, stone concrete, kerb stone or plastered surface over 10 cm width or girth not otherwise described for and applying one coat of synthetic enamel paint with approved tint or shade complete all as specified and directed by Engineer-in-Charge. |
| 16 | M&L for preparation of old painted wooden surfaces of any description over 10cm width or girth and applying one coat of synthetic enamel paint of tint/shade as approved complete all as specified and directed. |
| 17 | M&L for preparation of old painted steel or iron surfaces of any description over 10cm width or girth and applying one coat of synthetic enamel paint of tint/shade as approved complete all as specified and directed. |
| 18 | S&F PVC coloured wall paper to wall or floor with suitable epoxy based adhesive including removing old wall paper and making good surfaces complete all as specified and directed |
| 19 | M&L for obliterating old writing of any description, not exc 0.1 sqm with paint to match existing works complete all as specified and directed. |
| 20 | M&L for rewriting/repainting to existing writing letters or figures not exc 30 cm height in block Roman, Italian or Indian letters including stops, comma, arrows, brackets, dashes etc on sign board (Black or yellow base) including two coats of oil paint over a coat white base synthetic enamel paint complete all as specified and directed. |
| 21 | M&L for preparation of old decorated surfaces of over head reservoir 50000 Gln capacity at 21 metre staging height, and applying two coats of exterior acrylic emulsion paint in camouflage pattern, preparation of old decorated surfaces of railing, stair case and CI pipes of over head reservoir 50000 Gln capacity at 21 metre staging height, and applying two coats of synthetic enamel paint complete all as specified and directed. Note:- (a) Contractor shall take precaution for safety measures as per MES safety code. Contractor shall quote his rates keeping this aspect in mind and nothing extra on this account shall be payable to the contractor.(b) Unit rate of this item includes the following aspect:-(i) To provide complete scaffolding including safety belt to the workers as per directions of Engineer-in-Charge/GE. (ii) Nothing extra shall be paid on account of increase in height, hence work shall be carried out for complete surfaces varied at height and no claim on account of more height shall be entertained. Tenderer is hereby advised to see this factor before quoting his rate. M&L for disconnecting from the existing location cutting off worn out aluminium cable end and Supply, laying and testing in replacement cable XLPE Insulated ,screened, PVC bedded,galvanized steel strip or wire armoured,electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 sq mm 3.5 core including taking out existing cable of any size. Please Enable Macros to View BoQ information |