Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 24-06-2026 | REVISED CRITICAL DATES_2 | Date | 16-07-2026 |
| 2 | 15-06-2026 | REVISED CRITICAL DATES_1 | Date | 06-07-2026 |
| 3 | 01-06-2026 | REVISED CRITICAL DATES | Date | 24-06-2026 |
| Sl. No. | Item Description |
| 1 | =B2& \\" BoQ\\" BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: CHIEF ENGINEER (R&D) SECUNDERABAD Name of Work: SPECIAL REPAIRS TO BUILDING No. P-101, P-102, P-103 & P-104 AT NSTL, VISAKHAPATNAM Contract No: CERD/VIZ/TOKEN/04 OF 2026-2027 Bidder Name : PRICE SCHEDULE( This BoQ template must not be modified / replaced by the bidder and the same should be uploaded after filling the relevant columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # SlNo. Item Description Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency Rate in Figures to be entered by the Bidder Rs. Ps. Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e. DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit, if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT Without Taxes Total Amount Total Amount in Words |
| 2 | Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead of area 3 sq. metres and below complete all as specified and directed. |
| 3 | Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead of area 3 sq. metres and above complete all as specified and directed. |
| 4 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts complete and stacking within 50 metres lead : of area 3 sq.metres and below complete all as specified and directed. |
| 5 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts complete and stacking within 50 metres lead : of area beyond 3 sq.metres complete all as specified and directed. |
| 6 | Taking down shutters of any description exceeding 1 sqm but not exceeding 2.00 sq.m each including easing and adjusting and refixing the shutters in same opening including renewal of unserviceable screws complete all as specified and directed. |
| 7 | S&F, 2nd class H/W plain solid straight chowkats or frames rebated on the solid, wrought, framed rounded or chamfered put together with glue pinned at joints complete all as specified and directed. |
| 8 | M&L for plain framed panelled shutter 35mm thick (any number of panels) with panels of timber flat or both sides or of veneered particle board mediam density wood particle board with commercial face veneered supplied and fitted to chowkats complete all as specified and directed. |
| 9 | S&F, MS butt hinge cold rolled medium weight 125mm size complete all as specified and directed. |
| 10 | S&F, anodised aluminium barrel tower bolt 200mm long complete all as specified and directed. |
| 11 | S&F, 'D' type handle aluminium anodized 150mm in size complete all as specified and directed. |
| 12 | S&F, aluminium sliding bolt of size 300mm complete all as specified and directed. |
| 13 | Cutting holes in brick walls built in cement mortar for inserting holdfasts or lugs in stone masonry from the face of jamb and making good dismantled portion in cement concrete 1:2:4, type B1 as required complete all as specified and directed. |
| 14 | M&L for forming jambs to openings (to foregoing item), including cutting, toothing and properly bonding into old work, also facing, jointing and pointing to match existing work complete in CM 1:6 complete all as specified and directed. |
| 15 | M&L for two coat of synthetic enamel paint over a one coat of pink primer including preparation of new or previously untreated wooden or wood base surface of any description, not otherwise described over 10cm with or girth, complete all as specified and directed. |
| 16 | Hacking out old broken glass (any thickness, size, quality or description) from metal frame and provided & fixed with new ones complete all as specified and directed |
| 17 | S&F in repairs 4.8mm thick sheet glass ordinary quality and glazing with oil putty / wooden beading in squares not exceeding 0.5 Sqm each pane fixed in aluminium windows / door / partions complete all as specified and directed. |
| 18 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed. |
| 19 | S&F, framed work such as grills, gratings with ends of bars shouldered and/or riveted or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and hold fasts similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed. |
| 20 | M&L for preparation of new steel surfaces for ladders, angle sections, framed grills over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 21 | S&F in repairs motorised double leaf sliding door, door panel made of precoated galvanised steel, double-skinned, 40mm galvanised frame with one coat of epoxy primer sonic 1500J CE marked actuator in accordance with European directives and standards- three station push button pair of photocells with anodised aluminium vertical mountings size 10.0m x 4.0m complete all as specified and directed. |
| 22 | S&F, door closer aluminium (die cast) body hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000mm in width and of weight between 61 to 80 kgs and fixed complete all as specified and directed. |
| 23 | S&F in repair steel rolling shutters of thickness 1.25mm without ball bearing as specified including top cover, anchoring rod, hasp, staple and one shop coat of primer; erected in position as indicated, manual operated type with chain wheel and hand chain complete all as specified and directed. |
| 24 | M&L for preparation new steel and iron surfaces of any description not other wise described over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of primer on tee shutters complete all as specified and directed. |
| 25 | M&L for uPVC factory made, white colour louvered ventilators made of extruded profiles with figured / frosted glass louvers; profiles of frames and sash will be mitred cut and fusion welded at all corners including drilling of holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware, EPDM gasket, 1.2 ± 0.2mm thick galvanised steel profile to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners complete all as specified and directed. |
| 26 | M&L for uPVC factory made, white colour casement / sliding window three track made of extruded profiles with wall thickness of 2.3mm (+-0.2mm). Window profile with hollow sections with multichamber. Frame (88mm x 52mm), sliding sash (42mm x 57mm) sliding mesh sash (42mm x 57mm) sliding inter lock (one verticle length in each shutters) 45.4mm x 28mm) glazed bead (24.5mm x 16mm) will be mitered cut and fusion welded at all corners including railing of holes for fixing of hardwear, EPDM gasket, 1.2 ± 0.2mm thick galvanised steel frame (30mm x 18mm) 02 Nos, sliding sash (30mm x 18mm) sliding mesh sash (26mm x 10mm) profile |
| 27 | to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners, necessary zinc alloyed (powder coated) hardware like handles etc., steel rollers system, stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and required accessories and glass pane inserts of 5.5mm thick select quality sheet glass, rubber beading for fixing glass complete as directed by the Engineer-in-Charge.(A) Area not exceeding 2.00 sqm each. |
| 28 | S&F, factory made single extruded WPC (Wood Polymer Composite) solid door / window / ceosetory windows & other frames / chowkhat of size 45 x 70mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder / rice husk / wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum |
| 29 | compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of class A category with property of being termite / borer proof, water / moisture proof and fire retardant complete all as specified and directed. |
| 30 | Factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of 30mm size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder / rice husk / wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of class A category with property of being termite / borer proof, water / |
| 31 | moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-in-Charge.Note: Stainless steel butt hinges and necessary SS screws shall be paid separately. |
| 32 | S&F, aluminium sliding bolt of size 200mm complete all as specified and directed. |
| 33 | S&F, anodised aluminium barrel tower bolt 200mm long complete all as specified and directed. |
| 34 | Providing and fixing chromium plated brass butt hinges with necessary chromium plated brass screws complete brass butt hinges (light / ordinary type) : 100 x 70 x 4mm complete all as specified and directed. |
| 35 | Anodised aluminium handles 125mm with plate 175 x 32mm complete all as specified and directed. |
| 36 | S&F in repair zebra blinds for windows with all necessary fittings complete all as specified and directed. |
| 37 | M&L for preparation by sand blasting the wooden surfaces two coats of enamel paint over primer over two coats of wooden putty complete all as specified and direced. |
| 38 | Providing and fixing at all height 12mm thickness wall panelling with phenol bonded Bamboo Mat board conforming to IS:13958-1994 including providing and fixing to frame work made of 50mm x 50mm hardwood plugs including cutting brick work fixing in cement mortar and making good the wall etc. and also providing and fixing wooden moulded corner beading of triangular shape to the junction of panelling with iron screws all complete as per direction of Engineer-in-Charge. |
| 39 | M&L for powder coated anodised aluminium frame for doors, windows ventilators with one or more rebates including joining cleat for fixing complete all as specified and directed. |
| 40 | M&L for powder coated anodised aluminium door shutters, aluminium section weighing 0.55kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 02 Nos in each door, hinges, anodised aluminium snap beading, screws etc. complete all as specified and directed. |
| 41 | M&L for 12mm thick Prelaminatd particle board, interior grade, prelaminated both side with decorative choice lamination fixed with screws to timber frame work etc. complete all as specified |
| 42 | M&L for 4.8mm thick sheet glass of ordinary quality provide with rubber gaskets exceeding 0.5 Sqm complete all as specified and directed. |
| 43 | S&F, 4 lever brass mortize lock, vertical type size 100mm complete all as specified and directed. |
| 44 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead for thickness of tiles 10mm to 25mm complete all as specified and directed. |
| 45 | Providing and laying vitrified floor tiles in 800 x 800mm size (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/sqm including grouting the joints with white cement and matching pigments etc., complete all as specified and directed. |
| 46 | Providing and laying vitrified tiles in different sizes (thickness to be specified by manufacturer) with water absorption less than 0.08% and conforming to I.S. 15622 of approved make in all colours and shade in skirting, riser of steps, over 12mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/sqm including grouting the joint with white cement and matching pigments size of tile 600 x 600mm complete all as specified and directed. |
| 47 | Providing and laying vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved brand and manufacturer in all colours and shade, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) jointing with grey cement slurry @ 3.3 kg/sqm including grouting the joints with white cement and matching pigments. The tiles must be cut with the zero chipping diamond cutter only. Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Glazed vitrified tiles matt / anti skid finish size of tile 600 x 600mm complete all as specified and directed. |
| 48 | Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS:15622 (thickness to be specified by the manufacturer) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg/sqm, including pointing in white cement mixed with pigment of matching shade complete all as specified and directed. |
| 49 | Providing and fixing 18mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite stone slab colour black, Cherry / Ruby red area of slab over 0.50 sqm complete all as specified and directed. |
| 50 | Dismantling stone slab flooring laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50m lead complete all as specified and directed. |
| 51 | M&L for chequered cement concrete tiles 25cm x 25cm x 25mm thick with grey cement and pigments, set, jointed and pointed in neat cement slurry in floors over screed bed or bedding layer of mortar 15mm thick for laying floor finishes in CM 1:4 complete all as specified and directed. |
| 52 | Providing and laying polished granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18mm thick stone slab over 20mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing all as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab colour of Black, Cherry / Ruby Red or equivalent. |
| 53 | Supply and laying 60mm thick machine pressed precast concrete M-35 grade, interlocking paver blocks, PVC mould reflective type conforming to IS-15658 of any shape and size with grey cement and pigment complete laid all as specified and directed. |
| 54 | M&L for cement concrete type C2, 1:3:6 (40mm graded aggregate) 75mm thick as in sub base levelling course complete all as specified and directed. |
| 55 | M&L for sand filling under floors or in foundation including watering & consolidation complete all as specified and directed. |
| 56 | M&L for heavy duty flexible PVC Vinyl flooring of thickness not less than 2.0mm with properties like fire retardent and high abrasion resistant of make Marvel or equivalent make as per IS-3462 : 1986 complete all as specified and directed. |
| 57 | Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge in cement mortar complete all as specified and directed. |
| 58 | Half brick masonry with non modular fly ash bricks of class designation 10, conforming to IS:12894 in super structure above plinth and upto floor V level cement mortar 1:4 (1 cement : 4 coarse sand) complete all as specified and directed. |
| 59 | M&L for brick work with common burnt clay machine moulded perforated bricks of class designation 12.5 conforming to IS:2222 in superstructure above plinth level upto floor five level in cement mortar 1:6 (1 cement : 6 coarse sand) with F.P.S. (non modular) bricks complete all as specified and directed. |
| 60 | 12mm cement plaster of mix 1:4 (1 cement : 4 fine sand) for plastered surfaces of brickwork complete all as specified and directed. |
| 61 | M&L for preparation of newly plastered internal wall surface and applying two coats of distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre over white cement based wall care putty including complete all as specified and directed. |
| 62 | Taking down cement or cement lime plaster on brick or stone walls including raking out joints, hacking for key scrubbing down with water complete all as specified and directed. |
| 63 | M&L for rendering 5mm thick with WPC over 10mm thick on concrete surfaces or fair face of brick work or PCC block masonry in CM 1:4 finishing the surfaces fair and even complete all as specified and directed. |
| 64 | M&L for preparation of new plastered surfaces of walls and applying two coats of weather proof exterior emulsion over a coat of exterior primer complete all as specified and directed. |
| 65 | M&L for preparation of new surfaces of walls over alkali resitant primer and applying two coats of cement base paint complete all as specified and directed. |
| 66 | Providing and applying plaster of paris putty of 2mm thickness over plastered surface to prepare the surface even and smooth complete all as specified and directed. |
| 67 | M&L for preparing new plastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed. |
| 68 | M&L for rendering 15mm thick in CM (1:6) on concrete / brick masonry surfaces, finished even and smooth without using extra cement complete all as specified and directed. |
| 69 | M&L for rendering 10mm thick in CM (1:3) on ceiling of concrete surfaces, finished even and smooth without using extra cement complete all as specified and directed. |
| 70 | M&L for preparing new plastered surfaces of walls chalk whiting on plastered surface and applying two coats of oil bound distemper complete all as specified and directed. |
| 71 | Racking out joints in lime or cement mortar and preparing the surface for re-pointing or replastering, including disposal of rubbish to the dumping ground complete all as specified and directed. |
| 72 | M&L for filling the existing cracks on plastered surfaces of walls by using Dr. Fixit Crack-X Shrinkfree compound including preparation of surfaces before application by opening the cracks and cleaning off the dust, dirt etc., for ease of application of paste all as per manufacturer's instructions and making good surfaces complete all as specified and directed. |
| 73 | Chipping of unsound / weak concrete material in patched for 15mm average thickness from slabs, beams, columns etc., with manual chisel and/or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes complete with necessary scaffolding / staging and disposal of debris for all lead and lifts complete all as specified and directed. |
| 74 | Cleaning of reinforcement in pathes from rust from the reinforcing bars of dia upto 12mm to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry complete all as specified and directed. |
| 75 | M&L for mixing and applying SBR polymer modified cement mortar in proportion of 1:4 (1 cement : 4 graded coarse sand with polymer minimum 2% by wt. of cement used) 15mm average thickness each in three layers of as per specifications and directions of Engineer-in-Charge.Note: Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding / tapping with a blunt metal instrument. |
| 76 | Removing building materials etc other than soil to a distance 500m but not exceeding 1.0Km beyond the lead including in rates, including loading, unloading ant stacking at destinations complete all as specified and directed. |
| 77 | Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., upto floor five level, excluding the cost of centering, shuttering and finishing 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20mm nominal size derived from natural sources) complete all as specified and directed. |
| 78 | Steel reinforcement for R.C.C. work ready to use 'cut and bend' rebars of approved make from factory / workshop to construction site including placing in position and binding all complete upto plinth level, Thermo-Mechanically Treated bars of grade Fe-500D or more complete all as specified and directed. |
| 79 | Demolishing R.C.C. work manually / by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres complete all as specified and directed. |
| 80 | Demolition of cement concrete (unreinforced) of any description and provided in any position complete all as specified and directed. |
| 81 | M&L for PCC 100mm thick type B1, 1:2:4 using 20mm graded stone aggregate as in plinth protection finished even and smooth without using extra cement, filling joints with grade 'A' sealing compound complete all as specified and directed. |
| 82 | M&L for PCC 1:4:8 type D2 using with 40mm graded stone aggregate as in sunken floors complete all as specified and directed. |
| 83 | M&L for cleaning the inner concrete surface of the sunken floor using chisel and wire brush, remove all dirt, dust, loose particles by using air blower, identify the honeycomb and deteriorated areas if any which are to be patch repaired. Patch repairing all such areas by using SBR polymer modified cement mortar in proportion of 1:3, 15mm average thickness followed by providing and applying two coats of high performance elastomeric cementious water proofing coating complete all as specified and directed. |
| 84 | Supply only liquid water proofing compound complete all as specified and directed. |
| 85 | Dismantling 15 to 40mm dia G.I. pipe including stacking of dismantled pipes (within 50 metres lead) complete all as specified and directed.(a) Internal work - exposed on wall. |
| 86 | Supplying and laying of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings in trenches complete all as specified CPVC PIPE OUTER DIAMETER 20mm complete all as specified and directed. |
| 87 | Supplying and laying of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings in trenches complete all as specified CPVC PIPE OUTER DIAMETER 25mm complete all as specified and directed. |
| 88 | S&F in repairs bib taps, 15mm bore, cast copper alloy, chromium plated with crutch handle, short body with wall flange, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed. |
| 89 | S&F in repairs 15mm dia self-closing pillar taps, cast copper alloy, chromium plated, screwed for iron pipe and fixed complete all as specified and directed. |
| 90 | S&F in repairs 15mm dia angle valve cast copper alloy fancy type chromium plated with crutch handle and wall flange complete all as specified and directed. |
| 91 | S&F in repairs cast copper alloy, chromium plated 2 way bib cock 15mm dia with crutch handle with wall flange complete all as specified and directed. |
| 92 | S&F in repairs CP push taps for urinals with connecting CP pipes complete all as specified and directed. |
| 93 | Providing and fixing 8mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer-in-Charge. |
| 94 | Providing and fixing uplasticised PVC connection pipe with brass unions : 45cm length 15mm nominal bore complete all as specified and directed. |
| 95 | S&F, rotational moulded polyethylene water storage tanks, double layered of capacity 2000 ltrs (cylindrical vertical with closed top) hoisted and fixed in position complete including necessary GI tank nipples, taking down existing unserviceable tank complete all as specified and directed. |
| 96 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) complete all as specified and directed. |
| 97 | S&F, PVC floor trap with grating including jointing to waste pipe fixed in cement concrete type B1, 1:2:4 with dia of outlet 75mm complete all as specified and directed. |
| 98 | S&F in repairs PVC (SWR) pipe 110mm bore, single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed. |
| 99 | S&F, PVC (SWR) reducers 110/75mm bore complete all as specified and directed. |
| 100 | S&F, PVC (SWR) vent cowl 110mm dia complete all as specified and directed. |
| 101 | S&F, PVC (SWR) branch pipe, double (double Y) equal or equal with access door of 110mm bore complete all as specified and directed. |
| 102 | S&F, PVC (SWR) bends any radius provided with access door 110mm bore complete all as specified and directed. |
| 103 | S&F, PVC (SWR) junction single, (single T) equal or unequal of 110mm complete all as specified and directed. |
| 104 | S&F, 40mm bore dia High Density Polyethylene pipes (HDPE) of pressure rating 6 kgf/cm2 fixed to walls, ceilings or laid in floors including all specials complete all as specified and directed. |
| 105 | Providing and fixing in repair 100mm nominal dia Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings this includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete all as specified and directed. |
| 106 | S&F in repair vitreous china white flat back wash hand basin 550 x 440mm size including 15mm dia PVC connection 600mm long, brass CP waste coupling, 32mm dia PVC waste pipe, CI/MS brackets including cutting for and pinning in brackets or fixed with brass screws complete all as specified and directed. |
| 107 | Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100mm sand cast iron 'P' or 'S' trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe with manually controlled device (handle lever) conforming to IS:7231 with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : white vitreous china Orissa pattern W.C. pan of size 580 x 440mm with integral type foot rests complete all as specified and directed. |
| 108 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe with manually controlled device (handle lever), conforming to IS:7231 with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid complete all as specified and directed. |
| 109 | Providing and fixing white vitreous china flat back half stall urinal of size 580 x 380 x 350mm with white PVC automatic flushing cistern with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS:2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required : single half stall urinal with 5 litre P.V.C. automatic flushing cistern complete all as specified and directed. |
| 110 | Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75 x 50cm deep and 1.8cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6mm nominal size) and finished smooth granite stone of approved shade complete all as specified and directed. |
| 111 | Providing and fixing 600 x 450mm beveled edge mirror of superior glass (of approved quality) complete with 6mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete all as specified and directed. |
| 112 | Providing and fixing brass chromium plated tubular towel rail, 20mm dia, 'D' type, 60cm long between flanges complete all as specified and directed. |
| 113 | S&F in repair brass chromium plated soap dish complete all as specified and directed. |
| 114 | M&L for complete removal of existing treatment from internal wall, washing, rubbing down and stopping of distempered and painted surfaces over 2mm thich wall care putty and applying two or more coats 1st quality distempered (ready mixed) having VOC less than content less than 50 gms/litre required colour shade complete all as specified and directed. |
| 115 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : one or more coats on old work complete all as specified and directed. |
| 116 | French spirit polishing : one or more coat on old work complete all as specified and directed. |
| 117 | White washing with lime to give an even shade : old work (two or more coats) complete all as specified and directed. |
| 118 | M&L for complete removal of existing treatment on external surfaces of walls applying two coats of weather proof exterior emulsion over a coat of exterior primer complete all as specified and directed. |
| 119 | Taking down existing roof treatment of any description and removing the debris to a distance exceeding 500m and depositing outside MD land complete all as specified and directed. |
| 120 | (a) M&L for mechanical cleaning of surface to make it free from any bituminous residue / dirt, oil and greece.(b) M&L for cracks treatment by cutting open cracks and cleaning it from dirt / loose materials and filling with polyurethane based sealant with and including application of PU based primer. |
| 121 | (c) M&L for applying water based polyurethane modified dispersion (single component, cold applied, non toxic, VOC complaint) in 03 coats including 01 coat of primer of same materials after dilution of water at 50% or specific primer matching same materials as per manufacturer specification and as directed by GE/Engineer-in-Charge. |
| 122 | Properties of Polyurethane based chemical shall confirm to following Technical Parameters:-(i) Highly Elastic.(ii) UV Resistance.(iii) Adhesion to concrete.(iv) Tensile strength-not less than 2.0 N/Sq.mm for free film.(v) Elongation-not less than 300%.(vi) Solid content by weight-not less than 60%.(vii) Air / water permeability BSEN 12390 at 5 bar -72 hours should be NIL and minimum dry film thickness of water proofing membrane must be 1.0mm.(viii) Accelerated weathering (ASTM453) : Pass 1000 hours. (ix) Reaction to fire - non inflammable. |
| 123 | Dismantling plain steel sheeting, any gauge, thickness including Nainital or similar pattern roof coverings complete all as specified and directed. |
| 124 | S&F, pre-painted galvalume aluminium zinc coating GI based Corregated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws and washers complete all as specified and directed. |
| 125 | S&F, pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws and washers complete all as specified and directed. |
| 126 | S&F, plain galvanised mild steel sheeting in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275 complete all as specified and directed. |
| 127 | M&L for anti termite treatment at points of contact of wood work by chemical emulsion (in oil or kerosene based solution) @ 0.5 litre/hole by drilling 6mm dia holes at a downward angle of 45º at 150mm centre to centre and sealing the same complete all as specified and directed. |
| 128 | M&L for providing and injecting chemical emulsion for Post Constructional Anti-termite treatment along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc. in apron complete all as specified and directed. |
| 129 | M&L for treatment of soil under existing floors using emulsion @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement : 2 coarse sand) to match the existing floors complete all as specified and directed. |
| 130 | Dismantling aluminium fixed glazing including disposal of unserviceable material and stacking of serviceable material within 50 meters lead complete all as specified and directed. |
| 131 | S&F in repairs ACP cladding fabrication : 25mm x 50mm raw aluminium sections for substructure, 789 weather proof silicone, pressure taps and specification hardware complete all as specified and directed. |
| 132 | S&F in repairs glazing with 45mm x 45mm powder coated aluminium sections, aluminium pressure caps, 895 dowsil silicone for glass sticking, pressure taps, 789 dowsil weather proof silicone for top filling, 5mm tuffen glass with saint gobain company complete all as specified and directed. |
| 133 | Dismantling aluminium / Gypsum false ceiling including disposal of unserviceable material and stacking of serviceable material with in 50 meters lead complete all as specified and directed. |
| 134 | Providing & fixing false ceiling at all heights with GRG (Glass Fibre Reinforced Gypsum) false ceiling tiles of size 595 x 595mm with fully perforated 12mm thick micro tegular edged or 10mm thick square edged GRG false ceiling tiles of approved texture, design and patterns having moisture content less than 2%, humidity resistance of 99%, NRC 0.50 to 0.75 as per IS 8225:1987, Non combustible as per BS 476 (Part 4) - 1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on interlocking metal T-Grid of hot |
| 135 | dipped galvanised iron section of 0.33mm thick (galvanized @ 120 grams per sqm including both sides) comprising of main-T runners of size 15 x 32mm of length 3000mm, cross-T of size 15 x 32mm of length 1200 mm and secondary intermediate cross-T of size 15 x 32mm of length 600mm to form grid module of size 600 x 600mm, suspended from ceiling using galvanised mild steel items (galvanizing @ 80 grams per sqm) i.e. 50mm long, 8mm outer diameter M-6 dash fasteners, 6mm dia fully threaded hanger rod upto 1000mm length and L-shape level adjuster of size 85 x 25 x 2mm. |
| 136 | Galvanised iron perimeter wall angle of size 24 x 24 x 0.40mm of length 3000mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450mm center to center and 40mm long dry wall wood screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in-Charge. |
| 137 | M&L for repair provision of toughned glass partition and doors of thickness 12mm with all fittngs complete including complete all as specified and directed. |
| 138 | Taking down old point wiring complete for light / fan / socket (5/15 Amps) bell point complete with all light fittings accessories, such as switch sockets 5/15 Amps, ceiling rose including making good to the disturbed surface to match with the existing complete all as specified and directed. |
| 139 | Taking down old DBs, SPN, TPN, AC box and industrial socket of any size and capacity & making good to the disturbed surface to match with the existing complete all as specified and directed. |
| 140 | Taking down old sub main wiring / cable of any size and capacity including making good to the disturbed surface to match with the existing complete all as specified and directed. |
| 141 | Fixing only LED lights fittings with driver connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. |
| 142 | Hanging only ceiling fan and connecting up including provision of cable from ceiling rose or connector to fan complete all as specified and directed. |
| 143 | Fixing only exhaust fan and connecting up including provision of cable from ceiling rose / connector to fan complete all as specified and directed. |
| 144 | S&F, 25mm of steek conduit along with accessories in surface / recess including painting in case of surface conduit or cutting the wall and making good the same in case of recessed conduit as required complete all as specified and directed. |
| 145 | Wiring for light point / fan point / exhaust fan point / call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed PVC conduit with modular switch, modular plate suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as required complete all as specified and directed.(a) Group-C |
| 146 | Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as required complete all as specified and directed. |
| 147 | S&F, suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 5 pin 5/6 A modular socket outlet and 15/16 A modular switch, connections as required complete all as specified and directed. |
| 148 | S&F, suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin 15/16 A modular socket outlet and 15/16 A modular switch, connections as required complete all as specified and directed. |
| 149 | S&F, 3 pin 5 A ceiling rose on the existing junction box / wooden block including connections as required complete all as specified and directed. |
| 150 | S&F, two module stepped type electronic fan regulator on the exixting modular plate switch box including connections but excluding modular plate complete all as specified and directed. |
| 151 | Wiring for circuit / submain wiring alongwith earth wire 2 x 1.5 sq.mm + 1 x 1.5 sq.mm FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required for light point, 5 Amps socket, 16 Amps power socket & sub main wiring complete all as specified and directed. |
| 152 | Wiring for circuit / submain wiring alongwith earth wire 2 x 2.5 sq.mm + 1 x 2.5 sq.mm FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required for light point, 5 Amps socket, 16 Amps power socket & sub main wiring complete all as specified and directed. |
| 153 | Wiring for circuit / submain wiring alongwith earth wire 2 x 4 sq.mm + 1 x 4 sq.mm FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required for light point, 5 Amps socket, 16 Amps power socket & sub main wiring complete all as specified and directed. |
| 154 | Wiring for circuit / submain wiring alongwith earth wire 2 x 6 sq.mm + 1 x 6 sq.mm FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required for light point, 5 Amps socket, 16 Amps power socket & sub main wiring complete all as specified and directed. |
| 155 | Wiring for circuit / submain wiring alongwith earth wire 4 x 10 sq.mm + 2 x 6 sq.mm FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required for light point, 5 Amps socket, 16 Amps power socket & sub main wiring complete all as specified and directed. |
| 156 | Supplying, installation, testing & commissioning of panel light 2 x 2 ft, 36 watts, false ceiling / recessed mounted type of following body material and construction as per IS:10322 with driver as per the requirement with driver efficiency > 85%, operating voltage AC 140-270 volt, frequency 50/60 hz, operating temp range -5oC to 40oC, internal surge protection of 2.5 KV with short & open circuit protection, THD < 10%, P.F. > 0.95, IP 20, CRI > 80 UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5%), life time (LED, driver & electrical circuitry), of minimum 50000 burning hours with 70% of |
| 157 | initial Lumen maintained till life ends, CCT 3000oK / 4000oK / 5700oK / 6500oK (as per ANSI bin), SDCM (Standard Deviation Color Matching) < 3, maximum power consumption should not more than the specified rating and fixture shall be of relevant BIS standard. Manufactures Word Mark / Name Engraved / Embossing / Screen printing on housing complete in all respect including external connections with 1.5 sqmm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc, as required with minimum 05 year OEM warranty. |
| 158 | System lumen efficacy > 120 < 135 lm/Watt output, LM79 & LM80 test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management : heat sink of aluminium housing such that LED junction temperature shall not rise above 90oC). Powder coated die cast / extruded aluminium body (thickness > 1.20mm). |
| 159 | Supplying, installation, testing & commissioning of LED high bay light 150 watts, powder coated pressure die cast aluminium body with built in or separated driver as per the requirement with driver efficiency > 85%, input voltage : 140-270 volt AC, frequency 50/60 hz, operating temp range -15oC to 50oC, internal surge protection of 5 KV L, N, E as per IEC 61000-4-5, driver efficiency > 85%, THD < 10% as per IEC 61000-3-2, P.F. > 0.95, IP-66, IK-10, CRI > 80, under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle 30 deg-120 deg as per the application and the project requirement deg, suitable tiltable |
| 160 | fitting, life time (LED, driver & electrical circuitry) of minimum 50000 burning hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000oK / 4000oK / 5700oK / 6000oK / 6500oK (as per ANSI bin), SDCM (Standard Deviation Color Matching) < 5, maximum power consumption should not more than the specified rating and fixture shall be of relevant BIS standard complete in all respect including connections with 1.5 sqmm FRLS, PVC insulated copper conductor single core cable and earthing etc, as required with minimum 05 year OEM warranty. |
| 161 | System lumen efficacy > 135 lm/Watt output, LM79 & LM80 test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management : heat sink of aluminium housing such that LED junction temperature shall not rise above 90oC). |
| 162 | Supplying, installation, testing & commissioning of 72 watts street light LED fixture, powder coated pressure die cast aluminium body with built in or separated driver as per the requirement with driver efficiency > 85%, input voltage : 140-270 volt AC, frequency 50/60 hz, operating temp range -5oC to 50oC, internal surge protection of 5 KV L, N, E as per IEC 61000-4-5, driver efficiency > 85%, THD < 10% as per IEC 61000-3-2, P.F. > 0.95, IP-66, IK-10, CRI > 70, under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement, suitable to fit in |
| 163 | upto 65mm dia pipe, life time (LED, driver & electrical circuitry) of minimum 50000 burning hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000oK / 4000oK / 5700oK / 6500oK (as per ANSI bin), SDCM (Standard Deviation Color Matching) < 5, maximum power consumption should not more than the specified rating and fixture shall be of relevant BIS standard complete in all respect including external connections with 1.5 sqmm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc, as required with minimum 05 year |
| 164 | S&F, 12 way (4 + 36) double door surface / recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required complete all as specified and directed. |
| 165 | S&F, 8 way (4 + 24) double door surface / recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required complete all as specified and directed.Note for Sl item Nos. 150 & 151: Vertical type MCB TPDB is normally used where 3 phase outlets are required. |
| 166 | S&F, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc., as required (but without MCB / RCCB / isolator) complete all as specified and directed. |
| 167 | S&F, 20 A, 240 V, SPN industrial type socket outlet with 2 pole and earth, metal enclosed plug top alongwith 20 A 'C' curve, SP, MCB in sheet steel enclosure on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing & commissioning as required complete all as specified and directed. |
| 168 | S&F, 30 A, 415 V, TPN industrial type socket outlet with 4 pole and earth, metal enclosed plug top alongwith 30 A 'C' curve, TP MCB in sheet steel enclosure on surface or in recess with chained metal cover for the socket out let and complete with connections, testing & commissioning as required complete all as specified and directed. |
| 169 | S&F in repair MCCB, AC 415 V, 50 HZ, fixed type capacity 100 Amps, 4 pole, 36 KA suitable to be fixed in 4/6/8/12 way VTPN DB complete all as specified and directed. |
| 170 | S&F in repair MCCB, AC 415 V, 50 HZ, fixed type capacity 100 Amps, 4 pole, 30 KA suitable to be fixed in 4/6/8/12 way TPN DB complete all as specified and directed. |
| 171 | S&F, MCB DB double door SPN 12 way with 200 Amps rated copper bus bar complete all as specified and directed. |
| 172 | S&F, MCB DB double door SPN 8 way with 200 Amps rated copper bus bar complete all as specified and directed. |
| 173 | S&F, Amp rating 240V, 10KA 'C' curve Miniature Circuit Breaker (MCB) of SP 5 to 32 Amps and current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and directed. |
| 174 | S&F, Amp rating 240V, 10KA 'C' curve Miniature Circuit Breaker (MCB) of SPN 40 Amps and current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and directed. |
| 175 | S&F, Amp rating 240V, 10KA 'C' curve Miniature Circuit Breaker (MCB) of SPN 32 Amps and current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and directed. |
| 176 | S&F, MCB TPN 40 Amps, 4 pole with breaking capacity 10 KA along with replacement of old unserviceable one complete all as specified and directed. |
| 177 | Earthing with G.I. earth plate 600mm x 600mm x 6mm thick including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long (but with charcoal / coke and salt) as required complete all as specified and directed. |
| 178 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required complete all as specified and directed. |
| 179 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of size 10 Sqmm x 2 core direct in ground including excavation, sand cushioning, protective covering and refilling the trench as required complete all as specified and directed. |
| 180 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of size 10 Sqmm x 4 core direct in ground including excavation, sand cushioning, protective covering and refilling the trench as required complete all as specified and directed. |
| 181 | S&F, junction box for looping the cables complete all as specified and directed. |
| 182 | Providing and fixing of lightning conductor finial, made of 25mm dia 300mm long, G.I. tube, having single prong at top, with 85mm dia 6mm thick G.I. base plate including holes as required complete all as specified and directed. |
| 183 | S&F, aluminium strip 25 x 3.15mm with saddles and fixing screws for roof conductors and down conductors above ground complete all as specified and directed. |
| 184 | Providing and fixing 25mm x 5mm G.I. strip on surface or in recess for connections as required complete all as specified and directed. |
| 185 | Providing and fixing testing joint, made of 20mm x 3mm thick G.I. strip, 125mm long with 04 Nos. of G.I. bolts, nuts, check nuts and spring washers as required complete all as specified and directed. |
| 186 | Supplying, installation, testing & commissioning of microprocessor based intelligent addressable main fire alarm panel, central processing unit with the following loop modules and capable of supporting not less than 240 devices (including detectors) and minimum 120 detectors per loop and loop length upto 2 km, network communication card, minimum 320 character graphics / LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM), power supply unit (230 ± 5% V, 50 hz), 48 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel |
| 187 | shall have facility to connect printer to printout log and facility to have seamless integration with analog / digital voice evacuation system (which is part of the schedule of work under SH: PA system) and shall be complete with all accessories. The panel shall be compatible for IBMS system with open protocol BACnet / Modbus over IP complete as per specifications. |
| 188 | Note: (i) Design of the fire sensor layout is to be got approved from the department placing final order. (ii) Anything missed out in the technical specifications but technically required for efficient working of the system is deemed to be included.Two Loop Panel. |
| 189 | Supplying, installation, testing & commissioning of repeater panel wih 320 character / touch screen LCD display with inbuilt reset, acknowledge and silence switches as required complete all as specified and directed. |
| 190 | Supplying, installation, testing & commissioning of response indicator on surface / recessed MS box having two LED, metallic cover complete with all connections as required complete all as specified and directed. |
| 191 | Supplying, installation, testing & commissioning of intelligent addressable thermal detector with rate of rise cum fixed temperature thermistor complete with base as required complete all as specified and directed. |
| 192 | Supplying, installation, testing & commissioning of addressable manual call point as required complete all as specified and directed. |
| 193 | Supplying, installation, testing & commissioning of addressable horn cum strobe as required complete all as specified and directed. |
| 194 | Supplying, installation, testing & commissioning of fault isolator complete with base as required complete all as specified and directed. |
| 195 | Supplying, installation, testing & commissioning of addressable fire control module as required complete all as specified and directed. |
| 196 | Supplying and laying of 2 x 1.5 sqmm fire survival armoured cable, 600/1000V rated with annealed copper conductor having glass mica fire barrier tape covered by an extruded layer of cross linkable Ethylene Propylene Rubber (EPR) insulation and LSZH inner bedding, steel wire armouring & LSZH outer sheath as required complete all as specified and directed. |
| 197 | Supplying, installation, testing & commissioning of exit point directional sound speaker with voice and integral audio amplifier with selectable sound pulse patterns as required complete all as specified and directed. |
| 198 | Taking down old LT panel board after disconnecting all electrical connection, cables, MCCBs, MCBs of any size and capacity including making good to the disturbed surface to match with the existing complete all as specified and directed. |
| 199 | Supply, install, testing & commissioning, factory made and tested LT panel board of minimum size 1700 x 700 x 1200mm, indoor type, platform mounted, suitable for 415 volts 3 phase, 4 wire, 50 Hz AC supply system, having bus bar chamber with insulated aluminium bus bars 4 x 1000 Amps rating installed on porcelain insulators. The panel shall be dust and vermin proof, IP 52 class protection and made of 2mm CRCA sheet and 50 x 50 x 6mm thick angle iron frame work, powder coated finish over one coat of red oxide primer outside and |
| 200 | two coats of red oxide primer on inside, front / back opening type with aprons for cable entry and fixing 02 Nos danger notice plate of size 20 x 15cm with letter, figures and conventional skull bones in signal red colour and fixed front & back door LT panel with voltage and danger indicated in Hindi and English with double door shutter and locking arrangement internal wiring with PVC insulated, stranded copper conductor, FRLSH cables, IS-694 marked of adequate size but not less than 4 sqmm. The platform shall be such that it is as per site requirement including connections of all outgoing / incoming cables crimping suitable size aluminium |
| 201 | lugs for terminal connections of cables, necessary PCC foundation / brick with plastering to the cable duct / wall damaging area, all outgoing feeders various feeders shall be indicated by 50mm size letters in synthetic enamel white paint with control switches complete all as specified and directed. The scope of work includes the following items:Note: LT panel board should be confirming to relevant IS/ICE 61439-Part-I & II type test certified. (Location: HR wing-103 Bldg.) |
| 202 | (I) Incoming:(i) Air circuit breaker 630 Amps, 4 pole, (fixed type) and microprocessor based 415V, 65kA, AC supply, microprocessor based release for Overload (L), Short-time (S), Instantaneous (I) and Ground fault (G), (IS-2516 marked, IS/IEC 60947-2) complete - 01 No.(ii) Ammeter digital type, CT operated 0-630A range - 01 Set (with selector switch and CT).(iii) Voltmeter digital type 0-500V range - 01 No (with selector switch).(iv) Indicating lamp LED type 240 V 50 Hz AC supply set of three colour (RYB) - 01 Set. |
| 203 | (v) Indication lamp LED type 240 V 50 Hz AC supply, one set of two colour (Red & Green) for ON/OFF indication of ACB - 01 Set.(II) Outgoing:(i) MCCB 4 pole, microprocessor based 100A, breaking capacity 25 KA, 415 V, 50 Hz with OC, SC, EF protection - 07 Nos alongwith spreader terminals.(ii) Ammeter digital type, CT operated 0-100A range - 07 Set (with selector switch and CT). |
| 204 | (iii) Voltmeter digital type 0-500V range - 07 Nos (with selector switch).(iv) MCB TPN 63 Amp 'C' curve - 01 No.(v) Indicating lamp LED type 240 V 50 Hz AC supply one set of three colour (RYB) - 07 Set (for each outgoing). |
| 205 | Supply, install, testing & commissioning, factory made and tested LT panel board of minimum size 2000 x 600 x 1000mm, indoor type, platform mounted, suitable for 415 volts 3 phase, 4 wire, 50 Hz AC supply system, having bus bar chamber with insulated aluminium bus bars 4 x 800 Amps rating installed on porcelain insulators. The panel shall be dust and vermin proof, IP 52 class protection and made of 2mm CRCA sheet and 50 x 50 x 6mm thick angle iron frame |
| 206 | work, powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer on inside, front / back opening type with aprons for cable entry and fixing 02 Nos danger notice plate of size 20 x 15cm with letter, figures and conventional skull bones in signal red colour and fixed front & back door LT panel with voltage and danger indicated in Hindi and English with double door shutter and locking arrangement internal wiring with PVC insulated, stranded copper conductor, FRLSH cables, IS-694 marked of adequate size but not less than 4 sqmm. The platform shall be such that it is as per site |
| 207 | requirement including connections of all outgoing / incoming cables crimping suitable size aluminium lugs for terminal connections of cables, necessary PCC foundation / brick with plastering to the cable duct / wall damaging area, all outgoing feeders various feeders shall be indicated by 50mm size letters in synthetic enamel white paint with control switches complete all as specified and directed. The scope of work includes the following items:Note: LT panel board should be confirming to relevant IS/ICE 61439-Part-I & II type test certified. (Location: Work shop -102 Bldg, Panel-1) |
| 208 | (I) Incoming:(i) MCCB 4 pole, microprocessor based 500A, breaking capacity 36 KA, 415 V, 50 Hz with OC, SC, EF protection - 01 No alongwith spreader terminals.(ii) Ammeter digital type, CT operated 0-500A range - 01 Set (with selector switch and CT).(iii) Voltmeter digital type 0-500V range - 01 No (with selector switch).(iv) Indicating lamp LED type 240 V 50 Hz AC supply set of three colour (RYB) - 01 Set. |
| 209 | (II) Outgoing:(i) MCCB 4 pole, microprocessor based 100A, breaking capacity 25 KA, 415 V, 50 Hz with OC, SC, EF protection - 03 Nos alongwith spreader terminals.(ii) MCCB 4 pole, microprocessor based 63A, breaking capacity 25 KA, 415 V, 50 Hz with OC, SC, EF protection - 03 Nos alongwith spreader terminals.(iii) MCCB 4 pole, microprocessor based 32/40A, breaking capacity 16 KA, 415 V, 50 Hz with OC, SC, EF protection - 09 Nos alongwith spreader terminals. |
| 210 | (iv) Ammeter digital type, CT operated 0-100A range - 15 Set (with selector switch and CT).(v) Voltmeter digital type 0-500 V range - 15 Nos (with selector switch).(vi) Indicating lamp LED type 240 V 50 Hz AC supply one set of three colour (RYB) - 15 Set (for each outgoing). |
| 211 | Supply, install, testing & commissioning, factory made and tested LT panel board of minimum size 1800 x 600 x 1000mm, indoor type, platform mounted, suitable for 415 volts 3 phase, 4 wire, 50 Hz AC supply system, having bus bar chamber with insulated aluminium bus bars 4 x 800 Amps rating installed on porcelain insulators. The panel shall be dust and vermin proof, IP 52 class protection and made of 2mm CRCA sheet and 50 x 50 x 6mm thick angle iron frame work, powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer on inside, front / back opening type with aprons for cable entry and fixing 02 |
| 212 | Nos danger notice plate of size 20 x 15cm with letter, figures and conventional skull bones in signal red colour and fixed front & back door LT panel with voltage and danger indicated in Hindi and English with double door shutter and locking arrangement internal wiring with PVC insulated, stranded copper conductor, FRLSH cables, IS-694 marked of adequate size but not less than 4 sqmm. The platform shall be such that it is as per site requirement including connections of all outgoing / incoming cables crimping suitable size aluminium lugs for terminal connections of cables, necessary PCC foundation / brick with plastering to the cable |
| 213 | duct / wall damaging area, all outgoing feeders various feeders shall be indicated by 50mm size letters in synthetic enamel white paint with control switches complete all as specified and directed. The scope of work includes the following items:Note: LT panel board should be confirming to relevant IS/ICE 61439-Part-I & II type test certified. (Location: Work shop -102 Bldg, Panel-2) |
| 214 | (I) Incoming:(i) MCCB 4 pole, microprocessor based 500A, breaking capacity 36 KA, 415 V, 50 Hz with OC, SC, EF protection - 01 No alongwith spreader terminals.(ii) Ammeter digital type, CT operated 0-500A range - 01 Set (with selector switch and CT).(iii) Voltmeter digital type 0-500V range - 01 No (with selector switch).(iv) Indicating lamp LED type 240 V 50 Hz AC supply set of three colour (RYB) - 01 Set.(II) Outgoing:(i) MCCB 4 pole, microprocessor based 100A, breaking capacity 25 KA, 415 V, 50 Hz with OC, SC, EF protection - 05 Nos alongwith spreader terminals. |
| 215 | (ii) MCCB 4 pole, microprocessor based 63A, breaking capacity 25 KA, 415 V, 50 Hz with OC, SC, EF protection - 04 Nos alongwith spreader terminals.(iii) MCB DP 32 Amp 'C' curve - 03 Nos.(iv) Ammeter digital type, CT operated 0-100A range - 09 Set (with selector switch and CT).(v) Voltmeter digital type 0-500 V range - 09 Nos (with selector switch).(vi) Indicating lamp LED type 240 V 50 Hz AC supply one set of three colour (RYB) - 15 Set (for each outgoing). |
| 216 | Supply, install, testing & commissioning, factory made and tested LT panel board of minimum size 1250 x 600 x 1000mm, indoor type, platform mounted, suitable for 415 volts 3 phase, 4 wire, 50 Hz AC supply system, having bus bar chamber with insulated aluminium bus bars 4 x 800 Amps rating installed on porcelain insulators. The panel shall be dust and vermin proof, IP 52 class protection and made of 2mm CRCA sheet and 50 x 50 x 6mm thick angle iron frame work, powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer on inside, front / back opening type with aprons for cable entry and fixing 02 |
| 217 | Nos danger notice plate of size 20 x 15cm with letter, figures and conventional skull bones in signal red colour and fixed front & back door LT panel with voltage and danger indicated in Hindi and English with double door shutter and locking arrangement internal wiring with PVC insulated, stranded copper conductor, FRLSH cables, IS-694 marked of adequate size but not less than 4 sqmm. The platform shall be such that it is as per site requirement including connections of all outgoing / incoming cables crimping suitable size aluminium lugs for terminal connections of cables, necessary PCC foundation / |
| 218 | brick with plastering to the cable duct / wall damaging area, all outgoing feeders various feeders shall be indicated by 50mm size letters in synthetic enamel white paint with control switches complete all as specified and directed. The scope of work includes the following items:Note: LT panel board should be confirming to relevant IS/ICE 61439-Part-I & II type test certified. (Location: HSTT tank - 101 Bldg, Panel-1) |
| 219 | (I) Incoming:(i) MCCB 4 pole, microprocessor based 500A, breaking capacity 36 KA, 415 V, 50 Hz with OC, SC, EF protection - 01 No alongwith spreader terminals.(ii) Ammeter digital type, CT operated 0-500A range - 01 Set (with selector switch and CT).(iii) Voltmeter digital type 0-500V range - 01 No (with selector switch).(iv) Indicating lamp LED type 240 V 50 Hz AC supply set of three colour (RYB) - 01 Set.(II) Outgoing:(i) MCCB 4 pole, microprocessor based 200A, breaking capacity 36 KA, 415 V, 50 Hz with OC, SC, EF protection - 01 No alongwith spreader terminals. |
| 220 | (ii) MCCB 4 pole, microprocessor based 100A, breaking capacity 25 KA, 415 V, 50 Hz with OC, SC, EF protection - 04 Nos alongwith spreader terminals.(iii) MCB DP 40 Amp 'C' curve - 01 No.(iv) Ammeter digital type, CT operated 0-200A range - 05 Set (with selector switch and CT).(v) Voltmeter digital type 0-500 V range - 05 Nos (with selector switch).(vi) Indicating lamp LED type 240 V 50 Hz AC supply one set of three colour (RYB) - 05 Set (for each outgoing). |
| 221 | Supply, install, testing & commissioning, factory made and tested LT panel board of minimum size 1000 x 600 x 1000mm, indoor type, platform mounted, suitable for 415 volts 3 phase, 4 wire, 50 Hz AC supply system, having bus bar chamber with insulated aluminium bus bars 4 x 800 Amps rating installed on porcelain insulators. The panel shall be dust and vermin proof, IP 52 class protection and made of 2mm CRCA sheet and 50 x 50 x 6mm thick angle iron frame work, powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer on inside, front / back opening type with aprons for cable entry and fixing 02 |
| 222 | Nos danger notice plate of size 20 x 15cm with letter, figures and conventional skull bones in signal red colour and fixed front & back door LT panel with voltage and danger indicated in Hindi and English with double door shutter and locking arrangement internal wiring with PVC insulated, stranded copper conductor, FRLSH cables, IS-694 marked of adequate size but not less than 4 sqmm. The platform shall be such that it is as per site requirement including connections of all outgoing / incoming cables crimping suitable size aluminium lugs for terminal connections of cables, necessary PCC foundation / |
| 223 | brick with plastering to the cable duct / wall damaging area, all outgoing feeders various feeders shall be indicated by 50mm size letters in synthetic enamel white paint with control switches complete all as specified and directed. The scope of work includes the following items:Note: LT panel board should be confirming to relevant IS/ICE 61439-Part-I & II type test certified. (Location: HSTT tank - 101 Bldg, Panel-1) |
| 224 | (I) Incoming:(i) MCCB 4 pole, microprocessor based 200A, breaking capacity 36 KA, 415 V, 50 Hz with OC, SC, EF protection - 01 No alongwith spreader terminals.(ii) Ammeter digital type, CT operated 0-200A range - 01 Set (with selector switch and CT).(iii) Voltmeter digital type 0-500V range - 01 No (with selector switch).(iv) Indicating lamp LED type 240 V 50 Hz AC supply set of three colour (RYB) - 01 Set.(II) Outgoing:(i) MCCB 4 pole, microprocessor based 100A, breaking capacity 36 KA, 415 V, 50 Hz with OC, SC, EF protection - 01 No alongwith spreader terminals. |
| 225 | (ii) MCCB 4 pole, microprocessor based 63A, breaking capacity 25 KA, 415 V, 50 Hz with OC, SC, EF protection - 02 Nos alongwith spreader terminals.(iii) MCB DP 40 Amp 'C' curve - 01 No.(iv) Ammeter digital type, CT operated 0-100A range - 03 Set (with selector switch and CT).(v) Voltmeter digital type 0-500 V range - 03 Nos (with selector switch).(vi) Indicating lamp LED type 240 V 50 Hz AC supply one set of three colour (RYB) - 03 Set (for each outgoing). |
| 226 | M&L for earthing complete with galvanised iron plate electrode 600 x 600 x 6mm thick GI earthing lead buried directly in ground vertically to a depth not less than 2.25m deep below GL with the top edge of the plate at a depth not less than 1.5m from below normal GL connected to and including galvanised iron strip 25 x 5mm as earthing lead by means of nuts, bolts, washers, check nuts of GI and connected to earthing test point all as shown in electric plate No. 3 of SSR Part-I of 2010 and as specified or indicated and testing on completion including excavation / earthwork in any type of strat PCC (1:3:6) type C1 |
| 227 | earthing chamber, precast slab 50mm thick in cement concrete (1:2:4) type B1 (reinforced with welded steel wire fabric (XPM) weight not less than 4 kgs of 40mm bore medium grade and lugs with including GI earth strip with GI protection pipe of 40mm medium grade 7.5m long complete all as specified including testing and submission of test reports within permissible limit. |
| 228 | Note: (i) Rate quoted shall deemed to include cost of excavation in any type of statra, RFR and removal upto 50 meter, PCC pit, funnel and RCC cover plate, GI pipe etc.(ii) Earth resistance not exceeding should be as per specification in IS. |
| 229 | Supply and fixing, 25mm x 5mm G.I. strip on surface or in recess for connections etc. as required complete all as specified and directed. |
| 230 | Taking down/out old unserviceable aluminium cable / cross linked poly-ethylene (XLPE) insulated, LT cable of any size from pole / laid in trenches / through pipe in road crossings / paths / drains / ducts / floors / along poles / walls / ceilings / equipments etc., complete all as specified and directed. |
| 231 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of 10 Sqmm x 4 core direct in ground including excavation, sand cushioning, protective covering and refilling the trench as required complete all as specified and directed. |
| 232 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of 25 Sqmm x 4 core direct in ground including excavation, sand cushioning, protective covering and refilling the trench as required complete all as specified and directed. |
| 233 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of 50 Sqmm x 3.5 core direct in ground including excavation, sand cushioning, protective covering and refilling the trench as required complete all as specified and directed. |
| 234 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of 240 Sqmm x 3.5 core direct in ground including excavation, sand cushioning, protective covering and refilling the trench as required complete all as specified and directed. |
| 235 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of 300 Sqmm x 3.5 core direct in ground including excavation, sand cushioning, protective covering and refilling the trench as required complete all as specified and directed. |
| 236 | S&F, GI pipe light grade 100mm dia for cable protection complete all as specified and directed. |
| 237 | S&F, GI pipe light grade 50mm dia for cable protection complete all as specified and directed. |
| 238 | Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 1239/IS 3589 including welding, fittings like elbows, tees, flanges, tapers, nuts, bolts, gaskets etc. and fixing 100mm dia pipe on the wall / ceiling with suitable clamp / support frame and painting with two or more coats of synthetic enamel paint of required shade as required complete all as specified and directed. |
| 239 | S&F, single headed external yard hydrant valve with 01 No. 63mm dia instanteneous FM gun metal / stainless steel coupling and cast iron wheel, ISI marked conforming to IS 5290 (Type-A) single headed with blank gun metal / stainless steel cap and chain as required complete all as specified and directed. |
| 240 | S&F, first-aid hose reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required 20mm nominal internal dia water hose thermoplastic (textile reinforced) type-2 as per IS:12585 20mm nominal internal dia gun metal globe valve and nozzle. Drum and brackets for fixing the equipmets on wall. Connections from riser with 25mm dia stop gun metal valve & M.S. pipe and socket 30 meter complete all as specified and directed. |
| 241 | S&F, 63mm dia, 15m long RRL hose pipe with 63mm dia male and female couplings duly bound with GI wire, rivets conforming to IS 636 (type-A) as required complete all as specified and directed. |
| 242 | S&F, hose box made of 18 gauge MS sheet 800mm x 600mm x 250mm with double door with 4mm thick glasses and door frame made of 16 gauge MS sheet painted fire red outside and brilliant white inside at each stair case of the building complete all as specified and directed. |
| 243 | Construction of brick masonry valve chamber of size 0.9m x 0.9m x 0.9m (internal dimension) above ground level 30cm suitable for 150/100mm dia sluice valve, 15cm thick foundation using PCC 1:4:8 type D2 using 40mm graded stone aggregate over 15cm thick hardcore, 23cm thick brick wall, built in cement and sand mortar 1:4, 15cm thick internal and external plaster including top of floor in cement and sand mortar 1:3, finished even and smooth, without using extra cement, 3mm thick mild steel plate cover on 50mm x 50mm |
| 244 | x 6mm MS angle iron frame embedded in PCC 1:2:4 type B1 using 10mm graded stone aggregate coping having rectangular hinged opening of size with locking arrangement & handle made out of 10mm dia MS round bar, hold fasts, applying one coat of red oxide primer and two coats of synthetic enamelled paint to all steel surfaces and earth work in any type of soil including disposal of surplus soil to a distance not exceeding 50m complete all as specified and directed. |
| 245 | Non raising cast iron double flange sluice valve 100mm as per ISI/14846 PN 1.6 rating complete with Bronze body & wedge stainless steel spindle, gland packing, rubber gasket complete all as specified and directed. |
| 246 | Providing, installation, testing & commissioning of non-return valve of 100mm confirming to IS:5312 complete with rubber gasket, GI bolts, nuts, washers as required complete all as specified and directed. |
| 247 | Supply and laying, 80mm dia steel water tube medium grade galvanised with all fittings laid in trenches or fixed in wall complete all as specified and directed. |
| 248 | Supply and laying, 50mm dia steel water tube medium grade galvanised with all fittings laid in trenches or fixed in wall complete all as specified and directed. |
| 249 | Supply and laying, 25mm dia steel water tube medium grade galvanised with all fittings laid in trenches or fixed in wall complete all as specified and directed. |
| 250 | Gun metal gate valve 80mm (screwed type) on the existing pipeline, including testing & commissioning as required complete all as specified and directed. |
| 251 | Gun metal gate valve 50mm (screwed type) on the existing pipeline, including testing & commissioning as required complete all as specified and directed. |
| 252 | S&F, 25mm dia gun metal valve with iron wheel head screwed both ends for iron pipe and fixed complete all as specified and directed. |
| 253 | Cutting / drilling and fabrication the existing GI/CI/pipe upto 100mm dia pipe including CI/DI/GI tee, bend, tapper all necessary items complete all as specified and directed. |
| 254 | Excavating in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth; for foundation or for shafts, wells, cesspits, manholes, pire holes not exceeding 10 sqm on plan and not exceeding 1.5m in depth and getting out in soft / loose soil complete all as specified and directed. |
| 255 | Returning filling including spreading levelling, watering and well ramming in layers not exceeding 25cm in soft / loose soil complete all as specified and directed. |
| 256 | Removing excavated soil not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point in soil complete all as specified and directed. Total in Figures 0.0 0.0 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail