| Sl. No. | Item Description |
| 1 | Demolition of mud phuska as in roof of any thickness incl plastering and leeping etc (whether full thickness removed or only a part thereof) complete all as specified & directed. |
| 2 | Demolition of un-reinforced cement concrete in ground floors and pavings not exceeding 15 cm thickness. (Below or above ground level) complete all as specified and directed. |
| 3 | Providing plain cement concrete 1:2:4 type B0 (12.5mm graded stone aggregate), 50mm thick (averaging), as in levelling course, sub base and roof padding with mixing of WPC as per manufacturer's instructions, complete all as specified and directed.Note: WPC shall be measured and paid separately |
| 4 | Supply only integral water proofing compound (ISI Marked) complete all as specified & directed. |
| 5 | Preparation of surfaces of any description over 10 cm width or girth not otherwise described and applying two coats of bituminous aluminium paint @ 100 gm/sqm on top of membrane, complete all as specified & directed. |
| 6 | Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) > 78, solar reflection > 0.70 and initial emittance > 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm height along the parapet walls in the same manner complete all as specified and directed. |
| 7 | Cutting chases in brick walls, pinning in, making good to facings where required and pointing in cement mortar (1:3) for concealed pipe etc and making good, cutting not exceeding 10cm girth complete all as specified & directed by Engineer-in-charge. |
| 8 | Taking up or down steel/PVC tubing and connections 20mm bore ,complete all as specified and directed. |
| 9 | Taking up or down steel/PVC tubing and connections 15mm bore, complete all as specified and directed. |
| 10 | Taking up or down steel/PVC tubing and connections 25mm bore, complete all as specified and directed. |
| 11 | 15 mm bore Galvanized Steel tubes, medium grade including all fittings for flush pipes, water supply pipes etc., fixed to walls and ceilings or laid in floors, complete all as specified and directed. |
| 12 | 20 mm bore Galvanized Steel tubes, medium grade including all fittings for flush pipes, water supply pipes etc., fixed to walls and ceilings or laid in floors complete all as specified and directed. |
| 13 | Fixing only 20 mm bore steel tubing, medium grade incl all fittings and fixed to wall/ceiling or laid in floors, complete all as specified and directed. |
| 14 | 25 mm bore Galvanized Steel tubes, medium grade including all fittings for flush pipes, water supply pipes etc., fixed to walls and ceilings or laid in floors complete all as specified and directed. |
| 15 | Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store complete all as specified and directed. |
| 16 | Supply and fix 110mm bore PVC (SWR) bends any radius with access door etc complete all as specified and directed |
| 17 | PVC (SWR) rain water pipe, 110mm bore, single socketed in any length with rubber ring joints, fixed to walls with MS clamps made out of flat iron of size 25mm x 3mm including nuts bolts etc, fixed in repair complete all as specified and directed. |
| 18 | Supply and fix 1000 litres capacity rotational moulded polyethylene water storage tanks (Cylindrical vertical with closed top) Double layered, screwable lid, hoisted and fixed in position, including tank nipple, PTMT 20mm bore etc, including dismantling of existing water tank complete all as specified |
| 19 | 500 litres capacity rotational moulded polyethylene water storage tanks (Cylindrical vertical with closed top) double layered, white in colour, screwable lid, hoisted and fixed in position, including PTMT ball valve 20mm bore & PTMT tank nipple, etc, fixed as in repairs, complete all as specified and directed. |
| 20 | Framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forget into spikes; for ornamental and intricate design, framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 290-0, E-165, complete all as specified and directed. |
| 21 | Taking down chowkhats or frame exc. 1.5 Sqm and not exc 4 Square metre with shutters, without taking off shutters from the frame, complete all as specified and directed. |
| 22 | Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions), chowkhats/three track sliding window frame, extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge |
| 23 | Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws all complete as per architectural drawings and the directions of Engineer-in-charge. |
| 24 | Door closer hydraulically regulated of aluminium extruded section, designation No. 3, universal type, suitable for door shutters of 851 to 1000mm in width and of weight between 61 to 80 kg, fixed as in repair complete all as specified and directed. |
| 25 | 150mm long aluminum handle cast type anodized, complete all as specified. |
| 26 | 150 mm size aluminium anodized, barrel tower bolt of extruded section, complete all as specified and directed. |
| 27 | Aluminium alloy, anodized, sliding door bolt 250mm long, hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminum alloy, fixed as in repair complete all as specified and directed. |
| 28 | Mortice lock, verticle type, mild steel, 4 levers, size 100mm, brass body, complete all as specified and directed |
| 29 | Floor door stopper of brass body and tongue, anodized with hard drawn steel spring, fixed in floor (140mm size), complete all as specified and directed. |
| 30 | 5 mm thick ordinary quality tinted glass, fixed to aluminium frame work with rubber gasket, complete all as specified & directed. |
| 31 | Galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18 mm and fixed with stainless steel wire staples, complete all as specified and directed. |
| 32 | 4mm thick aluminium composite panel sheet (ACP) fixed with aluminium beading with rubber gasket including all necessary clips and fittings colour as approved by Engr-in-Charge all as specified and directed. |
| 33 | Two coats of synthetic enamel paint over a coat of red oxide primer on steel and iron surfaces over 10 cm width or girth including preparation of new surfaces complete all as specified & directed. |
| 34 | PCC 1:3:6 type C-1 (using 20m graded crushed stone aggregate) as in roof padding, sub base, mass concrete, foundation etc finished fair and even without using extra cement, complete all as specified and directed. |
| 35 | 15mm thick (average thickness) rendering on roof surfaces including flashings and junction of parapets etc finished even and fair in cement mortar 1:4 using water proofing compound as per manufacturer's instruction after brushing cement slurry complete all as specified and directed.Note: WPC shall be measured and paid separately |
| 36 | 3mm thick Atactic polypropylene polymer (APP) modified prefabricated five layer water proofing membrane, based polymeric membrane minimum weighing 3.6kg/sqm and reinforced with polyester non woven fabric (weight not less than 150 gm/sqm) laid over a coat of bitumen primer @0.40L/Sqm by same membrane manufacturer of density 0.87 to 0.89 kg/L at 25° C temperature and viscosity 70 to 160 CPS, over primer coat bonding material of blown bitumen 85/25 grade heated to working temperature of 180° C applied @1.2Kg/Sqm. The membrane shall be laid using butane torch and sealing all joints etc after preparing the surface as per standard practice and as per manufacturer instructions and finished with applying one coat of bituminous aluminium paint @100gm/sqm on top of membrane, complete all as specified & directed. |
| 37 | Material and labour cement concrete type B-0, 1:2:4 using (12.5 mm graded crushed stone aggregate) as in roof kerbs or mud stops, rounded or chamfered on edges in lintels upto 1.5m clear span, cills, steps, seismic and other similar bands, plinth courses, parapets and railings upto 60 cm in height, copings, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, including the use of forms or moulds with plain faces complete all as specified and directed. (Cement concrete item shall be reinforced, where ordered. Reinforcement shall be measured and paid separately). |
| 38 | Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) removing serviveable tiles to store and rubbish off the premises complete all as specified and directed |
| 39 | Non skid, first quality ceramic coloured tiles, 7 to 8 mm thick (square/ rectangular) area or each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile, over and including 15mm thick screed bed in cement mortar 1:4 complete all as specified and directed. |
| 40 | Glazed ceramic coloured tiles 7mm thick in vertical surface like skirting, dedo of area exc 0.13 sqm but not exc 0.27 sqm complete, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile, over a 15mm thick rendering in cement mortar 1:4 complete all as specified and directed |
| 41 | Coloured vitrified ceramic tiles, light shade, 10mm thick (square / rectangular) , area of each tiles n.exc 0.36 sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile, over 15mm thick screed bed in cement mortar 1:6, complete all as specified and directed. |
| 42 | 25mm thick PCC 1:2:4 type B-0 (using 20mm graded crushed stone aggregate) as in sub base finished fair and even without using extra cement, complete all as specified and directed. |
| 43 | Taking down cement plaster from brick walls or concrete surfaces including raking out joints, hacking out for key, scrubbing down with water complete all as specified and directed and removing rubbish etc. complete all as specified and directed. |
| 44 | Rendering 15mm thick on fair faces of brick work or concrete surface in CM 1:4 surface finished even and smooth (without using extra cement), complete all as specified and directed. |
| 45 | Material and Labour for preparation of new plastered or un-plastered surfaces of walls and applying two coats of cement base paint, complete all as specified and directed. |
| 46 | 15mm thick rendering in Cement and Sand mortar 1:6 on other than fair faces of concrete /brick surfaces finished even and smooth without using extra cement, complete all as specified & directed. |
| 47 | Preparation of new plastered surfaces and applying two coats of oil bound distamper over a coat of primer coat complete all as specified and directed |
| 48 | 4mm thick False ceiling fibre cement board, white in colour , 595mm x 595mm in size, fire and moisture resistance, fixed with and including standard GI snap grid framing (Powder coated) and suspended not exceeding 900mm below from ceiling with 3mm dia wire including clips and misc fittings etc in pattern as approved by GE, fixed as in repair (size of panel shall be of 605 x 605mm and GI snap grid framing shall be of 1mm thick standard section i.e. channels, angles, tee etc), complete all as specified and directed. |
| 49 | PVC lining coloured or selective pattern, as in repair PVC lining of hollow profile not less than 5mm thick and not less than 250mm wide intelocking type system as in wall/celing linings including end and intermediet U or L PVC sections as per manufacturer instructions , complete all as specified and directed(Note : Colour/design and pattern shall be as decided by the GE) |
| 50 | Demolition of brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc. but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed. |
| 51 | Brick work with sub class ‘B’ bricks, straight or curved on plan exc 6 metre mean radius built in cement mortar 1:6 complete all as specified & directed. |
| 52 | Wash hand basin, vitreous china, flat back , white of size 550X400mm, including brackets of suitable size, fixed as in repair complete all as specified and directed. |
| 53 | Beveled edge looking mirror, 5.5mm thick of selected quality glass, including wood finish PVC moulding mounted on 6mm thick ply or of PVC frame fixed to wall with screw and rawl plugs, complete all as specified and directed. |
| 54 | Vitreous china, wash down water closet pan, white, Pedestal pattern WC with ‘P’ or ‘S’ trap, (excluding, flushing cistern and flush pipe), including CP jet spray system complete all as specified and directed. |
| 55 | PVC valve less syphonic action type flushing cistern low level white with PVC inlet ball valve, float and handle, 10 ltrs capacity and connection to pipes, set with concrete and making good to floor, fixed in repair complete all as specified & directed. |
| 56 | Plastic water closet seat cover white closed pattern with flat bottom mild steel chromium plated or aluminium hinging device, fixed as in repairs, complete all as specified and directed. |
| 57 | Single piece EWC (one piece), minimum size 715 x 335 x 715mm, , snow white colour, S-trap with integraed flusing cistern, including slim soft close seat cover , fixed as in repairs, complete all as specified and directed. |
| 58 | Vitreous China half stall urinal, fixed against wall in cement mortar (1:2), securing urinal with and including 60mm long brass screws, pointing around urinal back in cement, including CP waste coupling, 32mm PVC waste pipe, fixed in repairs,complete all as specified and directed. |
| 59 | PVC (SWR) rain water pipe, 110mm bore, single socketed in any length with rubber ring joints, fixed to walls or laid in trenches with MS clamps made out of flat iron of size 25mm x 3mm including nuts bolts etc, fixed as in repair complete all as specified and directed. |
| 60 | 110 mm bore PVC (SWR) bends of any radius, complete all as specified and directed. |
| 61 | PVC connections 15 mm size with PTMT nuts of length 450 mm repairs complete all as specified and directed. |
| 62 | Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect, fixed as in repair complete all as specified and directed. |
| 63 | Brass chromium plated, tubular towel rail 20 mm dia. ‘D’ type, 60 cm long between flanges, fixed as in repair complete all as specified and directed. |
| 64 | Bib taps brass, fancy type, with wall flange, chromium plated, cast copper alloy, screwed down for iron pipe or for brass ferrule, suitable for 15mm bore pipe, fixed in repair complete all as specified and directed. |
| 65 | Stop valve, cast copper alloy, screwed down, high pressure with crutch or butterfly handle, screwed both and for iron pipe or for union, suitable for 15mm bore pipe, fixed as in repairs complete all as specified and directed. |
| 66 | 15mm bore pillar tap, fancy type, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure with or without lettered ‘Hot’ or ‘Cold’ with long screwed shanks and fly nuts, screwed for iron pipe, fixed in repair, complete all as specified and directed. |
| 67 | Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc. laid, bedded or laid bedded pointed in any mortar, all as specified. |
| 68 | Granite (of any type) tiles 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing, including 15mm thick in cement mortar 1:6, complete all as specified and directed |
| 69 | 75mm thick PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as in sub base etc, finished even and rough complete all as specified and directed. |
| 70 | Factory made Rubber moulded vibro compacted machine pressed cement concrete interlocking pre polished paver block, with grey cement and pigment, design as approved, any shape and size conforming to IS 15658-2006 of 60 mm thickness, M-35 Grade laid over and including 25mm thick sand cushioning, including dismantling of old tile complete all as specified and directed |
| 71 | Factory made Rubber moulded vibro compacted machine pressed coloured chequered cement concrete tiles 300mm x 300mm x 25mm thick (with grey cement and pigments), set, jointed and pointed in neat cement slurry with grey cement with pigment to match the colour of tiles, glossy finish, laid over and including 20mm thick screed bed in cement mortar 1:4, including dismantling of old tile complete all as specified and directed |
| 72 | PCC 1:3:6 type C-1 (using 20m graded crushed stone aggregate) as in side kerbs, ramp and like, finished fair and even without using extra cement, complete all as specified and directed. |
| 73 | Preparation of old plastered surfaces of walls incl scrapping down smoke, soot and efflorescent salts and treating oil & greasy spots, brooming down with steel wire brushing, removing nails & making good holes, cracks etc and applying two coats of cement base paint, complete all as specified and directed. |
| 74 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed |
| 75 | Mild Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240, complete all as specified & directed by Engineer-in-Charge |
| 76 | Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour, having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, incl dismantling of old existing sheet, complete all as specified and directed. |
| 77 | Preparation of old surfaces of walls/floor/chajja/ parapets and applying two coats of acrylic smooth exterior terracotta paint of required shade over and incl priming coat, complete all as specified and directed. |
| 78 | Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete all as specified and directed. |
| 79 | Demolition of reinforced cement concrete of any description in any position complete all as specified and directed. |
| 80 | Material and labour for reinforced cement concrete (M-25 design mix, using 20mm graded crushed stone aggregate) as in chajja and the like, complete all as specified and directed (reinforcement shall be measured and paid for separately). |
| 81 | Formwork to chajjas, troughs and similar items including edges fair finished, complete all as specified and directed. |
| 82 | Material and labour for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia. or securing with clips complete all as specified and directed. |
| 83 | Material and Labour mild steel TMT bars 6 to 8mm dia, cut to length, bent to shape required as in stirrups including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia. or securing with clips complete all as specified and directed. |
| 84 | Preparation of new surfacs and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces, complete all as specified and directed. |
| 85 | Preparation of old plastered surfaces and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over old surfaces, complete all as specified and directed. |
| 86 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custodyor for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete all as specified and directed. |
| 87 | Material and labour for point wiring with approved colour code multi stranded copper conductor, PVC insulated and unsheathed FRLSH cable of size 1.5 Sqmm ,1100 volts grade, two run of single core cable for phase & neutral and one run of single core multi stranded copper conductor, PVC insulated and unsheathed FRLSH cable of size 1.5 Sqmm ,1100 volts grade for earth continuity conductor to common earth and connected to earth dolly in and including new concealed PVC conduit terminated on and including new modular sunken box and suitable size of frame, cover for mounting switch, socket and regulator fixed on surface flush with wall , comprising of One light /bell/buzzer point controlled by one switch or one fan point controlled by one switch & fan regulator, complete all as specified and directed. Note : Unit rate is inclusive of making good the disturbed surfaces by provding by wall putty/POP after mason work and finshing to match the original and nothing extra shall be paid on this account. Note :Unit rate is inclusive of cutting chases in wall /foor/PCC and making good the disturbed surfaces to match the original and nothing extra shall be paid on this account. |
| 88 | All as per serial item 90 herein before but for socket outlet 3 pin 5 Amps on same board complete all as specified and directed |
| 89 | All as per serial item 90 herein before but for socket outlet 3 pin 6 Amps on independent board complete all as specified and directed |
| 90 | All as per serial item 90 herein before but One socket outlet three pin ,6/16 Amp, independent board, with 2.5 Sqmm (nominal area ) FRLSH cable & 2.5 Sqmm (nominal area ) cable as earth continuity conductor |
| 91 | Switch modular type (ISI marked), single pole, one way 6 Amps, one module (ISI marked), complete all as specified & directed. |
| 92 | Modular switch type bell push, single pole, 230 volt one module,(ISI marked), complete all as specified and directed. |
| 93 | Switch modular type (ISI marked), single pole, one way 16 Amps, one module (ISI marked), complete all as specified & directed. |
| 94 | Socket shutters outlet 2/3 pin 6 Amp modular type multi purpose two module (ISI marked), complete all as specified & directed. |
| 95 | Socket shutters outlet 2 in 1 pin 6/16 Amp modular type multi purpose combined 2 module (ISI marked), complete all as specified & directed. |
| 96 | Modular switch type stepped fan regulator, single pole, 230 volt two module complete all as specified and directed. |
| 97 | Modular white cover plate with frame, suitable for 2module complete all as specified and directed. |
| 98 | Modular white cover plate with frame, suitable for 3 module complete all as specified and directed. |
| 99 | Modular white cover plate with frame, suitable for 4 module complete all as specified and directed. |
| 100 | Modular white cover plate with frame, suitable for 6 module complete all as specified and directed. |
| 101 | Modular white cover plate with frame, suitable for 8 to 12 module as required, complete all as specified and directed. |
| 102 | Ceiling rose, PVC or polycarbonate of size 65mmx50mm three terminals (ISI marked) all as specified and directed by Engineer-in-charge. |
| 103 | Lamp holder, PVC/Polycarbonate type with back plate modular type fixed on wall suitable for batten fitting ,complete all as specified and directed. |
| 104 | LED bulb 12 watt self ballasted, retrofit type lamp with PBT body shell and DC diffuser CCT 6500K with fitting, complete all as specified and directed. |
| 105 | Inverter type tube light batten, 4 ft, 18/20 watt, 230 Vols, inbuilt lithium ion battery with charging time 8 to 10 hrs and back up time minimum 4 hrs, complete incl connecting up with three core flexible copper conductor cable of suitable size from ceiling rose fixed as in repair complete all as specified and directed. |
| 106 | LED panel recess mounted ultra slim 2'x2' - 36 watts ultra slim (cool day) ceiling light, aluminum extruded housing with milky diffuser, heat exchanger unit, LED driver, surge protection complete suitable for perfect lighting cutting hole of required size in POP/false ceiling making good disturbed including taking down any type ceiling fitting complete all as specified and directed. |
| 107 | Slim LED lights fitting, 2 feet, 1x 10W, inverter rechargeable, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose fixed as in repair complete all as specified and directed. |
| 108 | LED light fitting 1x9W/1X10W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size, complete all as specified and directed. |
| 109 | LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver,including lamp bracket upto 1.5metre length as per suitable for fitting including clamp with impact and corrosion resistant including thermal management in multiple optics complete with IP 66 protection, including taking down old street lght complete all as specified and directed. |
| 110 | Taking down u/s ceiling fans/wall fans/exhaust fans, removing blades and deposit to the MES store yard, complete all as specified and directed. |
| 111 | Overhauling of ceiling fan of any sweep/make i.e. Opening of fan and cleaning of ball bearing, filling grease/oil and changing of u/s cotter pin, nus, screws, bolts as required and cleaning of all body parts external/internal and reassembling the same, complete all as specified and directed. |
| 112 | Hanging of ceiling fan in repair and connecting up including provision 2 core single flexible cable for ceiling rose/ connector to fan including clean of blade / body cover etc complete all as specified and directed. |
| 113 | Ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) compelte all as specified and directed. |
| 114 | Exhaust fan energy efficient metallic blades heavy duty turbo force of size 300mm sweep, 1400 rpm, AC 230 volts complete with louvers shutters mounting on wall with holding down bolts, nuts, washers complete all as specified and directed. |
| 115 | Exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300mm and provision of flexible copper cable 3 core from ceiling rose to exhaust fan complete all as specified and directed. |
| 116 | Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amp complete all as specified and directed. |
| 117 | Taking down carefully old copper or aluminium sub main wiring of any Nos of wiring and size with earth wire on wooden batten/ surface conduit/ casing- capping complete with its all accessories and making good disturbed surfaces of wall , floors etc complete all as specified and directed. |
| 118 | Sub main wiring with two single core FRLSH PVC insulated and unsheathed cable with copper conductor of size 4 Sqmm (nominal area), 1100 Volt grade(with approved colour coding as per IS) with and including continuous earth wire of size 4 Sqmm PVC insulated and unsheathed FRLSH multi stranded copper conductor 1100 volts grade , and connected to main board drawing through PVC concealed conduit 25mm size(minimum size), t all as specified and directed. Note : (i) For the purpose of measurement, 2 single core of 4 sqmm and one single core earth cable of 4 sqmm cable shall be considered as 1 running metre. (ii) PVC conduit and cutting chases will be measured and paid separtely(iii) colour code shall be Red for phase, Black for neutral and green for earth |
| 119 | Sub main wiring with two single core FRLSH PVC insulated and unsheathed cable with copper conductor of size 10 Sqmm (nominal area), 1100 Volt grade(with approved colour coding as per IS) with and including continuous earth wire of size 10 Sqmm PVC insulated and unsheathed FRLSH multi stranded copper conductor 1100 volts grade , and connected to main board drawing through PVC concealed conduit 25mm size(minimum size), all as specified and directed. Note : (i) For the purpose of measurement, 2 single core of 10 sqmm and one single core earth cable of 10 sqmm cable shall be considered as 1 running metre. (ii) colour code shall be Red for phase, Black for neutral and green for earth |
| 120 | Sub main wiring with two single core FRLSH PVC insulated and unsheathed cable with copper conductor of size 16 Sqmm (nominal area), 1100 Volt grade(with approved colour coding as per IS) with and including continuous earth wire of size 16 Sqmm PVC insulated and unsheathed FRLSH multi stranded copper conductor 1100 volts grade , and connected to main board drawing through PVC concealed conduit 25mm size(minimum size), all as specified and directed. Note : (i) For the purpose of measurement, 2 single core of 16 sqmm and one single core earth cable of 16 sqmm cable shall be considered as 1 running metre. (ii) colour code shall be Red for phase, Black for neutral and green for earth |
| 121 | Cutting chases in brick walls, pinning in, making good to facings where required and pointing in cement mortar (1:3) to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc and cutting chases for concealed water tubing or concealed conduit wiring etc and making good, cutting not exceeding 10cm girth Complete all as specified and directed . |
| 122 | Disconnecting the power supply and taking down carefully by unscrewing from boards fittings and fixtures such as DBs, Junction Box, Panels of any size complete with all MCCB's ,MCB's etc and removing from site, complete all as specified and directed . |
| 123 | Vertical TPN distribution board double door flush mounting with provisions for MCCBs incomer upto 100 to 125 Amps & outgoing 4 way having IP 43 protection, complete all as specified and directed . |
| 124 | TPN distribution board double door flush mounting with provisions for MCB TPN 4 way having IP 43 protection complete all as specified and directed . |
| 125 | MCB DB, IP 43 protection, powder coated double door with locking arrangement suitable for surface and flush mounting, 12 way SPN with 200 Amps busbar 240V, completed all as specified and directed. |
| 126 | MCCB, 125 Amps, four pole, 3 phase , 16KA, 415 volt with adjustable thermal and maganetic release, with proper thimble complete all as specified and directed |
| 127 | MCB , TPN, 63 Amp 415 volts, 16 KA , 'C' series including connection with suitable size aluminium / copper lugs complete all as specified and directed |
| 128 | RCBO for earth leakage, overload & short circuit protection double pole, 40 to 63 amps, m240 V, 30mA with all incoming/outgoing connections with suitable size lugs, complete all as specified and directed |
| 129 | MCB SPN, 240 volt, 40Amps to 63Amps, 10 KA , 'C' series including connection with suitable size aluminium / copper lugs complete all as specified and directed |
| 130 | MCB SP, 240 volt, 6 Amps to 32 Amps, 10 KA , 'C' series including connection with suitable size aluminium / copper lugs complete all as specified and directed |
| 131 | Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation etc or for shaft, wells, cesspits, manholes, pier holes etc not exceeding 10 sqm on plan and getting out in soft and loose soil all as specified & directed by Engineer-in-Charge. |
| 132 | Returning filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm depth , complete all as specified and directed. |
| 133 | Removal of excavated material to distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point , complete all as specified and directed. |
| 134 | Cutting of existing bitumen road/CC road of size 30 cm x 30 cm for laying of underground cable with pipe, where boring of hole is not feasible and incl necessary earth work and refilling the same in layers, well ramming, watering and matching with the existing surface with 150 mm thick PCC 1:2:4, type B-1 and curing the same with wet gunny bags and removing debris to a distance not leass than 50 m, complete all as specified and directed. |
| 135 | 32mm outer dia, double walled corrugated (DWC) HDPE duct pipe conforming to IS 14930 Part-II with anti rodent and non flame propogating properties of approved colour with fittings for cable protection from approval make complete , all as specified and directed |
| 136 | XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 50 sqmm, 3.5 core, laid in trenches , sleeving through pipes of fixed on poles & wall or laid under floors inlcuding jointing with suitable size of alumunium lugs as specified and directed. |
| 137 | Replacement for fabrication, install, testing and commissioning of wall mounted sheet metal busbar chamber, CPRI approved grouted with nut and bolts (with proper locking arrangement and holes to distribute circuits) of size not less than 600x 500 x 300mm with copper strip 40mm x 6mm (04 Nos) of length 450mm with approved colour coded and PVC adhesive coated, IP-54 as per IS-13947 protection fixed on insulator with the help of nut/bolts including provision of 10 Nos 08 mm dia 50mm long nut/ bolts with 02 Nos of washer connected with 16 sqmm single core colour coding stranded copper cable with thimble/ lugs including one MCCB, 125 Amps, four pole 3 Phase 25 KA, 415 volt with adjustable thermal and megnetic relase complete having adjustable type base frame and equal space around MCCB as incommer one No, making good distrubed surfaces to match with original complete all as specified and directed by Engr-in -Charge.NOTE:-Contractor shall submit drawing of panel to GE through Engr-in-Charge for approval before placing order for procurement. |
| 138 | Earthing complete with galvanized steel earth plate electrode 60cmx60cmx6.00mm thick, burried directly in ground vertically to a depth not less than 2.25m below normal ground level, with top edge of the plate not less than 1.5m below normal ground level, earth plate surrounded by 15cm thick and packed alternate layers of charcoal dust and common salt, connected with and including earth lead of GI wire 4mm dia (8 SWG) by means of bolts, nuts, check nuts and washers of galvanized iron or thimbles and other end of the earth wire connected to main switch board and protected by galvanized iron pipe light grade 15mm dia bore including watering pipe 20mm dia bore GI light grade (ISI marked) with funnel and wire mesh, including all necessary excavation and earth work, PCC chamber in plain cement concrete (1:3:6) type C-1 and pit cover of presast RCC with MS frame etc and all as shown in electrical plate No 3 of MES Sch Part-I (2009), complete including dismantling of old earthing, all as specified and directed. Note(s) :-(i) RCC pit cover shall be pre-cast of RCC (1:2:4) type B-1, 80mm thick reinforced with XPM not less than 4Kg/Sqm.(ii) PCC chamber shall be constructed 500 mm away from the edge of earth pit.(iii) Rate shall include earth lead and protection pipe of length 7.5m(iv) Earth resistance should be less than 3Ohm. In case the test results are not found below 3Ohm, complete earthing will be redone without any extra cost to Govt.(v) unit rate including protection pipe and GI wire 4.00mm dia from top to earth plate upto 7.5 meter Please Enable Macros to View BoQ information |