| 1 | Wiring for light point / Fan point / Exhaust Fan point / Call Bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch , modular plate , suitable GI box and earthing the point with 1.5 sqmm.FRLS PVC insulated copper conducotor single core cable etc. as required . |
| 2 | Group-C |
| 3 | Wiring for Light/ power plug wiring with 2 x 4 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed PVC conduit alongwith 1 No. 4 sq.mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 4 | Wiring for Circuit/ sub main Wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed PVC conduit as reqd. |
| 5 | 2 x 1.5 sq.mm + 1 x 1.5 sq.mm. earth wire |
| 6 | 2 x 2.5 sq.mm + 1 x 2.5 sq.mm. earth wire |
| 7 | 4 x 4 sq.mm + 2 x 4 sq.mm. earth wire |
| 8 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 9 | 5/6 A switch |
| 10 | 15/16 A switch |
| 11 | 3 pin 5/6 A socket outlet |
| 12 | 6 pin 15/16 A socket outlet |
| 13 | Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required. |
| 14 | 6 Module (125mmX75mm) |
| 15 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular switch, connections etc. as required. |
| 16 | Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box / wooden block including connection etc as required. |
| 17 | Installation, testing and commissioning of wall barcket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required. |
| 18 | Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required. |
| 19 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board , 415volts, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnection , powder painted including, earthing etc as required. (But without MCB/RCCB/Isolator). |
| 20 | 8 way (4 + 24), Double door |
| 21 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA 'C' curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 22 | Single Pole |
| 23 | Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing andcommissioning etc. as required. |
| 24 | 100 A |
| 25 | Supply of 15W ,4000K rating LED Recessed type Round light fittings similar to Make: Philips model No. DN172 15S LED DL G2 (NW) or its equivalent. |
| 26 | Supply of 12W ,4000K rating LED Surface Cobe light fitting similar to Make: Havells Crysta Deco Surf COB 12 W 4 K Rose Gold B or its equivalent. |
| 27 | Supplying of 1-star Decorative ceiling fans of 1200mm sweep (Brown Gold Mist), Make: HAVELLS Model: Astura ES or equivalent. |
| 28 | Supplying and drawing following 2-core 4.0 sqmm. FRLS PVC insulated copper conductor cable in the existing surface/recessed steel/ PVC conduit/DWC as required. |
| 29 | Supplying of following size XLPE insulated PVC outer sheathed with galvanised round steel wire or steel srtip armoured aluminium conductor power cable of 1.1 Kv grade conforming to IS 7098 (Part-I) 1988 amended upto date. |
| 30 | 3.5 core X 50 sq. mm |
| 31 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the open surface as required. |
| 32 | Above 35 sq. mm and upto 95 sq. mm |
| 33 | Supplying and laying of DWC HDPE pipe of following size, ISI marked along with all accessories like socket, bend, couplers etc. Conforming to IS 16205 (Part 24): 2018/IS 14930 (Part 2) : 2001, complete with fitting and cutting, jointing etc. on ground/surface etc as required. |
| 34 | 63 mm dia (OD-63 mm & ID-50 mm nominal) |
| 35 | Supplyingh and laying of following size DWC HDPE pipe ISI marked alomg with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. direct in ground (50 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc. complete as required. |
| 36 | 63 mm dia (OD-63 mm & ID-50 mm nominal) |
| 37 | Supplying and laying of DWC HDPE pipe of following size, ISI marked along with all accessories like socket, bend, couplers etc. Conforming to IS 16205 (Part 24): 2018/IS 14930 (Part 2) : 2001, complete with fitting and cutting, jointing etc. on surface/wall including providing clamping arrangement etc as required. |
| 38 | 50 mm dia (OD-50 mm & ID-38 mm nominal) |
| 39 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1.KV grade of following size in the existing DWC/PVC/RCC/ HUME/GI/METAL pipe as required. |
| 40 | Above 35 sq. mm and upto 95 sq. mm |
| 41 | Supplying and fixing Single door 4-way, triple pole and neutral, sheet steel, MCB distribution board, on surface/recess, including TPN MCB of rating 32 Amps C-type, complete with necessary connetions. make : Anchor : 98294 & 98038 |
| 42 | Supplying and fixing of Modular AC DB box including 20Amps SP MCBwith plastic enclosure and plug top including connection as required Similar to Anchor code 98488 or its equivalent. |
| 43 | Supplying and fixing Wall fan of 400mm sweep (White colour) similar to Havells Sameera or its equivalents complete with necessary connetions as required. |
| 44 | Supply and fixing of FP MCCB of 100A with breaking Capacity 16kA similar to Havells Cat No.IHLGNT0100# or its equivalent complete with connection. Please Enable Macros to View BoQ information |