| 1 | Demolition of cement concrete (unreinforced) in ground floors and pavings n.exc 15cm thickness (below or above ground level). |
| 2 | M&L 25mm thick cement concrete type B-O, 1:2:4 (12.5mm graded agg ) as in sub flooring. |
| 3 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified. |
| 4 | M&L for Non-skid ceramic tiles, coloured, 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sq m but not exceeding 0.18sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed bed or bedding layer of cement mortar 1:6 complete all as specified. |
| 5 | M & L for Glazed coloured ceramic tiles in vertical surface 450X 300X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match over 10mm thick rendering in CM 1:4 complete all as specified. |
| 6 | M&L 75 mm thick PCC 1:3:6 Type C-1 using 20mm crushed stone aggregate as in plinth protection and finished even and smooth without using extra cement. |
| 7 | Bitumastic filling, with 80/25 bitumen and coarse sand mixture. 1:3 by weight, as in plinth protection complete all as specified & directed. |
| 8 | Taking down chowkats or frames(without taking off shutters from the frame) area exc 1.5 Sqm but n.exc 4.0 Sqm each. |
| 9 | Taking down chowkats or frames(without taking off shutters from the frame) area not exc 1.5 Sqm each. |
| 10 | S&F solid PVC door frame of sixe 50mmx47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube in opening as per specification and drawing. |
| 11 | S&F Anodised aluminium frame of doors, windows & ventilators with one or more rebates including joining cleat for fixing etc. |
| 12 | S&F Anodiesed aluminium door shutters, aluminium section weighing 0.55 Kg/m incl. necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each doors, hinges, anodiesed aluminium snap beading screw etc. complete all as specified. |
| 13 | S&F Anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.) hinge type B-21 100mm long (2 no.) suitable handle (1 no.) complete all as specified |
| 14 | S&F factory made soilid panel PVC Door shutter 30mm thick (Stype) consisting of frame made out MS frame shall be covered with heat moulded plain coloured PVC 'C' channel having PVC sheet stripof 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheet for top rail, lock rail, & bottom rail; Panneling of plain colour PVC sheet to be fitted in the M.S. frame welded/sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification and drawing. |
| 15 | S&F 150mm aluminium anodised barrel tower bolts of extruded section and fixed. |
| 16 | S&F 100mm aluminium anodised barrel tower bolts of extruded section and fixed. |
| 17 | S&F 250mm aluminium alloy anodised sliding bolts with hasp, staple and fixing clips of sheet, cast or extruded section fixing bolts and sliding bolts of extruded section or cast aluminium alloy and fixed. |
| 18 | S&F 125mm aluminium handles, cast type ,anodised and pattern/design as approved. |
| 19 | S & F butt hinges, 100mm medium weight, cold rolled mild steel. |
| 20 | S&F 4 mm thick Aluminium composite Panel for door including necessary joining cleats, glazing clips, ruber neoprene packing, anodised aluminum snap beading screws etc. complete all as specified |
| 21 | Hacking out old broken glass (any thickness) , size, quality or description ) from metal frame including punching or drilling out old glazing pins. |
| 22 | S&F 4mm thick sheet glass, ordinary quality and glazing with oil putty in squares n,exc 0.5 Sqm, each pane. |
| 23 | Dismantling of plain or corrugated steel sheeting, any guage, thickness from roof covering complete all as specified. |
| 24 | S&F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified. |
| 25 | S&F pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified. |
| 26 | Dismantling wrought iron or mild steel work of any description not otherwise provided. |
| 27 | S&F Mild steel work as in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, Tee, angle channel or flat sections) including distance pieces, cleats etc.(Fe-410-W(Gde E-250)Quality-A) |
| 28 | S&F Mild steel work as in compound girders and stanchions, latticegirders, aerial masts, staging for water tanks and like including caps bases, splices etc built up from two or more beam or channel sections or angles with plates or pipe section including all lattice bars, stiffeners, gusset plates etc..(Fe-410-W(Gde E-250)Quality-A) |
| 29 | S&F 2000 Ltrs capacity, rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part – I, including 20mm ball brass valves, high pressure with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed to 20 mm bore steel tube and dismantling existing water tank and removing complete all in repair as specified. |
| 30 | Taking up or down steel tubing 15 mm bore, and connections, including cleaning for re-fixing or removal to store in repairs complete all as specified. |
| 31 | S & F 15 mm bore, steel water tubing, medium grade, galvanized, with all fitting and fixed complete to walls and ceiling or laid into floor in repairs complete all as specified. |
| 32 | Fixing only 15 mm water tubes, any grade, to walls and ceilings or laying in floors complete all as specified. |
| 33 | Taking up or down steel tubing 20 mm bore, and connections, including cleaning for re-fixing or removal to store in repairs complete all as specified. |
| 34 | S & F 20 mm bore, steel water tubing, medium grade, galvanized, with all fitting and fixed complete to walls and ceiling or laid into floor in repairs complete all as specified. |
| 35 | Fixing only 20 mm water tubes, any grade, to walls and ceilings or laying in floors complete all as specified. |
| 36 | S&F in repairs bib taps, cast copper alloy, chromium plated, screwed down, screwed for iron pipe or for brass ferrule and fixed for 15 mm bore steel tube complete all as specified. |
| 37 | S&F in repairs 15mm bore stop valve/angle valve cast copper alloy chromium plated fancy type screwed down, high pressure, with crutch or butter fly handles. |
| 38 | S&F PVC valve less syphonic action type low level flushing cistern white of capacity 10 Ltrs with inlet valve float and fixed to water closet with PVC flushing pipe 32mm dia |
| 39 | S&F in repairs Vitreous china squatting pan 'Orissa pattern' size 580X 440 mm white with integral foot rest (exluding flushing cistern and flush pipe) including connection to trap,concrete and to flushing pipe, anti-syphonage pipe, etc. complete including making good to floor complete all as specified. |
| 40 | S&F in repairs Vitreous china wash down water closet pan (pedestal pattern), white, including flush pipe of polyethylene of low or high density or PVC 32 mm dia., plastic water closet seat closed pattern with cover and hinging device and trap with connection complete all as specified. |
| 41 | S&F Chromium plated jet for EWC complete all as specified. |
| 42 | S&F in repairs Vitreous china wash basin, white, flat back, size 550 X 400 mm including fixing with brackets exclusive of fixing of supply and waste pipe and 32 mm chromium plate waste fitting with long screwed shanks and fly-nuts complete all as specified. |
| 43 | Supply only 15mm bore pillar tap, cast copper alloy, with capstan heads, fancy type chromium plated, screwed down high pressure, with or without lettered ‘Hot' or ‘Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and directed. |
| 44 | S&F in repairs vitreous China Urinal, half stall type, white with 32mm bore PVC waste pipe of length 900mm to 1200mm and including urinal spreader of PTMT any colour for fixing with 15mm dia pipe including connection to flushing pipe and outgoing pipes with 32mm bore PVC waste pipe of length 900mm to 1200mm. |
| 45 | S&F in repairs PVC connections 15 mm size with PTMT nuts of length 450 mm in repairs complete all as specified. |
| 46 | S&F in repairs Brass chromium plated shower rose 125mm size for iron pipe or for unions and fixed to 15 mm bore steel tube complete all as specified. |
| 47 | S&F in repairs Aluminium Anodised tubular towel rail, 20 mm dia. 60 cm long between flanges complete all as specified. |
| 48 | S&F in repairs Soap dish, cast copper alloy, chromium plated with screws complete all as specified. |
| 49 | S&F in repairs 600 mm X 450 mm bevelled edge mirror of selected quality glass, mounted on 6 mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screw and cup washers complete all as specified. |
| 50 | S&F 110 mm bore, PVC (SWR) pipes single socketed/ elbow/ tee, in any length with rubber ring joints, laid in trenches or in floors after dismantling old one complete all as specified. |
| 51 | S&F in repairs 75 mm bore, PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors after dismantling old one complete all as specified. |
| 52 | S&F in repairs 75 mm bore PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified. |
| 53 | Taking down cement or cement lime plaster any description on brick or stone walls etc including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed. |
| 54 | M&L 15mm thick rendering on brick work or concrete surfaces in cement mortar 1:4 finished even and smooth without using extra cement (with water proofing compound). |
| 55 | M&L two coats cement base paint on plastered surface including preparation of newly plastered surfaces. |
| 56 | M&L one coats of synthetic enamal paint to steel surfaces of any discription not otherwise described over 10cm width or girth preparation of old surfaces complete all as specified. |
| 57 | M&L for preparing new or previously untreated steel surfaces of any description not otherwise described over 10cm width or girth and applying two coat of synthetic enamel paint over a coat of red oxide primer complete all as spd and directed. |
| 58 | Dismantling wall and ceiling boards of any description or any thickness including cover fillets as directed. |
| 59 | S&F powder coated GI snap grid of size 605 X 605mm frame work for false ceiling including hangers 2mm dia G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of G.I. flat 40 x 3mm size 60mm long and expansion hold fasteners 12.5mm dia 40mm long whereever required or tie on structural steel complete all as specified and directed. |
| 60 | S&F Exposed metal frame ceiling with 8mm thick decorative laminated calcium silicate board of siliceous and calcareous material reinforced with cellulose fibre for fixing in 600mmX600mm grid (frame work for ceiling shall be measured and paid seprately) complete all as specified and directed. |
| 61 | S& F for 110mm PVC (SWR) bends complete all as specified. |
| 62 | S& F for 110mm PVC (SWR) junction single, (Single T) equal or unequal complete all as specified. |
| 63 | S& F 110mm PVC (SWR) vent cowl complete all as specified. |
| 64 | S& F 75mm /110mm PVC (SWR) reducer complete all as specified. |
| 65 | M&L for preparation of old surfaces & applying one coats of white wash on wall as specified. |
| 66 | Demolition of cement concrete (unreinforced) in ground floors and pavings n.exc 15cm thickness (below or above ground level). |
| 67 | M&L chequered cement concrete tiles 20cmx 20cmx 25mm thick,set, jointed & pointed in neat cement slurry in floors with grey cement and pigments over & including 20mm thick screed in cement mortar 1:6 |
| 68 | M&L for 75 mm thick P.C.C 1:4:8 type B-2 using 40mm graded stone agg as in sub base of floor complete all as specified and as directed. |
| 69 | Excavation in trenches not exc 1.5 mtr wide or n.exc 1.5 mtr in depth for pipe line, drains, foundations of sewarage lines or manholes and like and getting out in soft/loose soil. |
| 70 | M&L PCC (1:4:8) type D-2 using 40 mm graded stone aggregate as in foundation filling and mass concrete all as specified. |
| 71 | Demolition of precast concrete block walling masonary, built in cement mortar or cement lime mortar incl all quoins, arches, pillars, etc but excluding ashlar facing, dressed stone work and precast concrete articles. |
| 72 | M&L 1:3:6 type C-1 precast cement concrete (20mm graded stone aggregate) block masonary with solid blocks exc 10 cm in width and not exc 20cm in width and setting in cement mortar 1:6. |
| 73 | M&L 15mm thick rendering on brick work or concrete surfaces in cement mortar 1:4 finished even and smooth without using extra cement (with water proofing compound). |
| 74 | M&L three coats of white wash on plastered surface including preparation of newly plastered surfaces. |
| 75 | Returning, filling in, spreading, leveling watering and well ramming in layers n,exc 25 cm thickin soft/loose soil. |
| 76 | Removing excavated soil to a distance not exc 50 mtr and depositing where directed at a level not exc 1.5 mtr above starting point |
| 77 | M&L cement concrete 1:4:8 type D-2 using 40mm graded stone agg as in bed to drain pipe, incl packing under and haunching against the sides of pipe 150mm bore after they are laid and tested as specified. |
| 78 | Demolition and breaking up drain pipes (salt, glazed ware, AC or reinforced concrete) (200mm internal dia) of any description set in cement mortar. |
| 79 | M&L 150mm internal dia reinforced concerete pipes, class NP2, laid and jointed complete with collars and jointed as specified. |
| 80 | Demolition of RCC work of any description and any position. |
| 81 | M&L for precast RCC 1:2:4 type B-1 using 20mm graded stone agg as in cover slab and like except set in cement mortor 1:4 complete incl necessary form work all as specified. |
| 82 | M&L mild steel TMT bars 6-8mm dia bar cut to length, bent to shape required including cranking, bending spirally for hoping for fencing posts and binding with mild steel wire (annealed) not l3ess than 0.9 mm dia all as specified. |
| 83 | Pumping out/dewatering of soakage wells septic tanks etc of any size and depth by machanical means i.e. pumping sets etc and removing the muddy water in liquid or semi-liquid state to a pit of sufficient size and depth at a place exc. 250mtrs away from defence land and burried in ground including necesary excavation earth work and spreading of bleaching powder complete all as specified. |
| 84 | Desilting/desludging the septic tanks/ soakage wells/manholes of any size and any depth etc by manual labour or mechanical means and removing the sludge in liquid or semi-liquid state out side defence land complete all as specified. |
| 85 | Demolition of Concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed |
| 86 | M&L for PCC 1:2:4 B1, 20mm graded stone aggregate as in surface channels and drains complete all as specified and directed |
| 87 | Extra forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement including forms, mould, mitred/stopped ends etc. complete all as specified and directed |
| 88 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. |
| 89 | M&L for point wiring using approved colour coding as per IS by using FRLS PVC insulated 1.5 Sqmm multistranded,1100 volt grade copper conductor cable unsheathed type, alongwith 1.5 Sqmm FRLS PVC insulated stranded copper conductor cable for continous earthing in & incl casing capping point wiring with accessories having ISI mark for one light/fan/bell point/5 amp indep/power point/same board controlled by one switch complete all as specified and directed. |
| 90 | All as per item No 89 here-in-before but for one multipin socket outlet 5 Amp but using 2x 1.5 + 1 x 1.5 sqmm multistranded FRLS copper cable on the independent board |
| 91 | All as per item No 89 here-in-before but for one multipin socket outlet 5 Amp on the same board with other switches |
| 92 | All as per item No 89 here-in-before but for one multipin socket outlet 15 Amp, but using 2 x2.5 +1 x 2.5 sqmm multistranded FRLS copper cable, independent board |
| 93 | S&F in replacement of switch piano type 5 Amp, 230 Volt, flush type single pole one way complete all as specified and directed. |
| 94 | S&F in replacement of socket outlet multipin 5 Amp 230 Volt flush type complete all as specified and directed. |
| 95 | S&F in replacement of switch piano type 15 Amp, 230 Volt, flush type single pole one way complete all as specified and directed. |
| 96 | S&F in replacement of socket outlet multi pin 15 Amp 230 Volt flush type complete all as specified and directed. |
| 97 | S&F In replacement of for Lamp holder, PVC/Polycarbonate type with back plate suitable for Angle/batten fittings complete all as specified and directed |
| 98 | S&F of rechargeable led bulb minimum 4 Hrs Battery backup 9 Watt B-22 Base complete all as specified and directed. |
| 99 | S&F in rplacement of Ceiling rose, 3 terminal, PVC isolated body complete all as specified and directed |
| 100 | S&F in replacement of LED light fitting 20W, 220 volt AC, having colour temperature daylight (6500K), Decorative ultra slim square profile LED lighting fixture with extruded polycarbonate, connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. |
| 101 | S&F in replacement LED light fitting 1x10W/1X12W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size. |
| 102 | S&F including flushing in wall MCB distribution board vertical TPN 4 way 415 volt AC doublr door sheet with bus bar neutral earth bar including provision of MCB TPN 63 amp conforming to IP 43 as incomer complete all as specified and directed. |
| 103 | S&F MCB TPN 63 amp 415 volt with bearing capacity of 16 KA complete all as sp[ecified and directed. |
| 104 | Supply and fix Sheet metal enclosure for DBs 8 way, double door, 240 Volt, with 200 Amps rates bus bar |
| 105 | S&F in replacement of MCB 6 to 32 amp rating 240V, 10KA 'B' curve, Single pole in the MCB DB complete with connection testing and commissioning complete all as specified and directed. |
| 106 | S&F in replacement of MCB SPN 40 amp rating 240V, 10KA 'B' curve, Single pole in the MCB DB complete with connection testing and commissioning complete all as specified and directed. |
| 107 | Supply, laying and drawing in and including 20 mm dia casing caping including cutting of chases for laying conduit making good the surfaces as per existing surfaces or as directed on walls 02 runs of IC x 6.00 sqmm (Main Cable and neutral) and one run of IC x 6 sqmm (as earth wire) of stranded copper conductor PVC insulated unsheathed cables of 1100 volts grade conforing to IS : 694 of 1990 complete including connection all as specified and directed. |
| 108 | Supply & laying LT UG XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 Volts grade cross-sectional area 16 sqmm 4 core as per IS specification laid through GI pipe/on floor/wall complete all as specified and directed |
| 109 | Supply and laying of GI pipe light galvanized with all fitting laid in trenches for cable proctection of 50 mm bore all as specified and directed. |
| 110 | M&L in replacement of Earthing complete with galvanised steel earth plate electrode 600×600×6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion all as directed. |
| 111 | Excavation in trenches not exc. 1.5 m wide and not exc 1.5 mtr deep in soft loose soil for laying / taking up/ taking down of cables and getting out and leveling of bottom surface to required level all as specified and directed by Engineer- in- Charge. |
| 112 | Returning filling in,. Including spreading, leveling,. Watering and well ramming soil in layers not exceeding 25 cm thick all as specified and directed. |
| 113 | Removing excavated material (i.e. soil) from site to a distance n. exec 50 mtrs away and depositing where directed at a level n. exc. 1.5 mtr above the starting point all as specified and directed by Engineer-in-Charge. |
| 114 | S&F of double wall corrugated HDPE duct pipe of 65 mm outer dia PN 10 of approved colour with fittings for cable protection complete all as directed. |
| 115 | S&F metal type exhaust fan single phase 230/240V of 300 mm sweep including louvre & cutting of holes in a round shape and including fixing the exhaust fan complete all as specified and directed. |
| 116 | Supply & laying LT UG XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 Volts grade cross-sectional area 10 sqmm 4 core as per IS specification laid through GI pipe/on floor/wall complete all as specified and directed |
| 117 | Schedule of Credit Please Enable Macros to View BoQ information |