| Sl. No. | Item Description |
| 1 | Taking down cement plaster on wall, ceiling, chajjas, roof projections, lintel, etc of any description including raking out joints, hacking for key and scrubbing down with water etc and disposing off the rubbish materials out side MD land complete all as specified and directed. |
| 2 | M&L for 20 mm thick rendering in cement mortar (1:4) on fair faces of brick work in two layers (10mm & 10mm) mixed with water proofing compound in top layer 200 ml per beg of cement or as per manufacturer's instructions finishing the surface fair and even without using extra cement complete all as specified and directed. Note: Water proofing compound shall be measured and paid seperately under relevant item of schedule 'A'. |
| 3 | Supply only liquid water proofing compound conforming to IS: 2645 - 1975 specification complete all as specified and directed. |
| 4 | M&L for 15mm thick rendering in cement mortar 1:6 on fair face/other than fair face of brick work or concrete surface finished fair and even (without using extra cement) complete all as specified and directed. |
| 5 | M&L for rendering 5mm thick in cement mortar 1:3 on ceiling, soffits of slabs, chajjas, columns and beams etc and finished the plastered surface even and smooth without using extra cement complete all as specified and directed. |
| 6 | M&L for preparing new Plastered surfaces of walls and applying two coats acrylic-based distemper of shade as approved by GE over a coat of primer over a coat of putty (average 1.5mm thick) on surfaces of wall as per the manufacturer's instructions complete all as specified and directed. Note: Application of new finishes to be carried out mechanically by authorised applicator and as per the manufacturer's instructions. |
| 7 | M&L for complete removal of existing treatment of old plastered surfaces of walls and applying two coats acrylic based distemper of shade as approved by GE over a coat of primer over a coat of putty (average 1.50mm thick) on surfaces of wall including preparation as per the manufacturer's instructions complete all as specified and directed. Note: Application of new finishes to be carried out mechanically by authorised applicator and as per the manufacturer's instructions. |
| 8 | M&L for preparing new Plastered surfaces of walls and finishing the walls with Acrylic smooth exterior anti-fungal paint of required shade as approved by GE : New work (Two coats applied @1.67 Ltr/10 Sqm over and including priming coat of exterior primer applied @ 2.20 Kg/ 10 sqm) over and incl a coat of putty (average 1.50mm thick) complete all as specified and directed. |
| 9 | M&L for complete removal of existing treatment of old plastered surfaces of walls and finishing the walls with Acrylic smooth exterior anti-fungal paint of required shade as approved by GE : New work (Two coats applied @1.67 Ltr/10 Sqm over and including priming coat of exterior primer applied @ 2.20 Kg/ 10 sqm) over and incl a coat of putty (average 1.50mm thick) including preparation complete all as specified and directed. |
| 10 | M&L for preparing newly plastered or unplastered surface of ceiling and applying three coats of white washing complete all as specified and directed. |
| 11 | M&L for preparartion of old surfaces of ceiling & applying two coat of white washing complete all as specified and directed. |
| 12 | Demolition of brick work built in cement mortar of any description complete all as specified and directed. |
| 13 | M&L for brickwork with flyash old size bricks, straight or curved on plan to any radius in half brick thick walls, built in cement mortar 1:4 complete all as specified and directed. |
| 14 | M&L for brickwork with fly ash old size bricks, straight or curved on plan exc 6m mean radius, built in cement mortar 1:6 complete all as specified and directed. |
| 15 | Dismantling floor, hearth or wall tiling including cement mortar bedding (including backing), removing serviceable tiles and rubbish off the premises complete all as specified and directed |
| 16 | M&L for joint free non - skid coloured ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tile, laid over and including 15 mm thick screed bed or bedding layer of cement mortar in (1:6) for laying floor finishes complete all as specified and directed. |
| 17 | M&L for Vitrified Ceramic tiles double charged 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.42 sqm but n.exc 1.00 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tile, laid over and including 15 mm thick screed bed or bedding layer of cement mortar in (1:6) for laying floor finishes complete all as specified and directed. |
| 18 | M&L for Vitrified Ceramic tiles double chagged 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.42 sqm but n.exc 1.00 sqm, on vertical surfaces such as skirtings, dados and risers to steps etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tile, complete all as specified and directed. |
| 19 | M&L for Vitrified Ceramic tiles light shade 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tile, laid over and including 15 mm thick screed bed or bedding layer of cement mortar in (1:6) for laying floor finishes complete all as specified and directed. |
| 20 | M&L for Vitrified Ceramic tiles light shade 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, on vertical surfaces such as skirtings, dados and risers to steps etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tile, complete all as specified and directed. |
| 21 | M&L for 10 mm thick rendering/ backing coat in CM (1:3) as in vertical surfaces of skirting, dados etc complete all as specified and directed. |
| 22 | M&L for glazed ceramic coloured tiles/ digital elevation tiles of size 300 X 450 X 7-8 mm/300 X 600 X 7-8 mm thick as on vertical surfaces of wall such as skirting, dado, riser etc. in Bath, WC and Kitchen set and jointed in neat cement slurry and pointed in with tile grout of approved make to match the surface of tile as approved by Engr-in-Charge complete all as specified and directed. |
| 23 | M&L for 18 to 20 mm thick granite (of any type) work (table rubbed and polished) in steps, Jambs, pillars, window cills, cooking platforms, corner shelf, Flat shelf and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, laid over and including 15 mm thick cement plaster (1:4) including rounding the exposed edges of granite complete all as specified and directed. |
| 24 | All as per item No 23 here in before but as in skirting ( 12 to 15 mm thick) but on 10 mm thick rendering/ backing coat in CM (1:3) complete all as specified and directed. |
| 25 | Dismantling plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed. |
| 26 | S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 27 | M&L for steel work in trusses, purlins, posts and the like using tubular/ square hollow section including special shaped washer, Nuts and bolts etc. complete using ERW or induction butt welded tubes/SHS conforming I.S.1161-2014/IS 4923-1977 grade St-240 including dismantling complete all as specified and as directed. |
| 28 | S&F anodised aliminium snap grid frame work for false ceiling confirming IS:733, 737 & IS:1285; including hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia 40mm long all as specified and as directed. |
| 29 | S&F 4mm thick (E-Boards) Non asbestos fibre cement building boards fixed or laid/ inserted to timber/GI/Aluminium framework with screws in ceiling complete all as specified and as dirceted. |
| 30 | Taking down tarfelt with cement plaster from roof surfaces and lowering and removing the same to a distance exc. 50m and n. exc. 100m incl roughening of old concrete suirface of roof by wire brushing and cleaning the surface to remove all loose dust etc complete all as specified and directed. |
| 31 | M&L for water proofing treatment to RCC roof slab including parapet comprising of the following course of tretment/specified from bottom to top (a) Applying Bituminous primer @ 0.40 Ltr per Sqm over plastered surface of roof including parpet surfaces. Bitumnious primer shall be 'Tar Mastic' manufactured by M/S STP LTD or 'EMW FLATE; manufactured by M/S Texsa India Ltd. (b) Over the priming coat laying one layer APP based polymeric membrane with non woven polyster fabric weight not less than 160 gms per sqm. Polymeric membrane shall be taken to a height of 60cm (mim) and than inserted th groove of perafit wall and shall be finished a membrance flashing (c) Application of two coats of Bituminous aluminum paints over the polymeric memnrance after necessary preparation and cleaning, Thickness 3mm.Note :- Laying APP based polymeric membranceshall be done by tourch on mathod or as per manufacture insturction. (ii) A minimum overlap of 100 mm shall be maid at the end 75mm shall be maid at the side and sealed overlaped and joint as per manufacture instructions. Make :- \\"SUPER THERMOLAY\\" manufacturer by STP Ltd of MOPLY FP manufacture by Texsa India Ltd. |
| 32 | M&L for 10mm thick screedd bed or bedding layeres in cement mirter (1:4) in order to maintain proper slope over existing roof surface for applying single component acrylic polymner modified, fininshed even and smooth without using extra cement mixed with water proofing compound complete all specified and as directed. Note :- Polymeric membrane and WPC shall be measured and paid spearately under relevant items of this Sch 'A'. |
| 33 | M&L for 25mm thick PCC 1:2:4 type B0 (Using 12.5 mm graded stone aggregate) mixed with water proofing compound and laid on RCC slab as base layer for roof tratment rufning the topo surface of concrete by using broom stick while the cocrete is green complete all as specified. Note:- WPC paid separatly under relivant items. |
| 34 | S&F factory made UPVC white colour Sliding window three track (Area n exc 2.0 Sqm each) made of extruded profiles with wall thickness of 2.3 mm (+- 0.2mm) window profiles with jollow section with multi chamber, frame (88 mm x 52 mm), sliding sash (42 mm x 67 mm) sliding mesh sash (42 mm x 57 mm ) sliding interlock (one vertical length in each shutters) ( 45.50 x 28 mm), glazing bead (24.5 mm x 16 mm ) will be miterd cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc, making arrangement for fixing of hardware, EPDM gasket, 1.2 +- 0.2 mm thick galvanised steel frame (30 x 18 mm ) 2 nos sliding sah (30mm x 18 mm) sliding mesh sash (26 mm x 10 mm) profile to be inserted in required profile, frame will be fixed to the wall with 8 mm x 100 mm long fasteners, hardware (Touch Lock of Zinc alloyed ( white power coated) steel roller system, stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and required accessories including taking down steel windows with guard bars and making good distrubed jambs, soffits, cills, wall as per existing. |
| 35 | S&F 4.8mm thick sheet glass panes ordinary quality n.exc 0.5sqm each fixed to UPVC window frame complete complete all as specified and directed. |
| 36 | S&F Powder coated aluminium louvered ventilators of size n exc 0.50 Sqm area with glass louvers, without sash bars of aluminium sections weighing not less than 0.605kg/m for frame of size 40x20x2mm including necessary jointing cleats, glazing cleats, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings and 5.5mm thick tinted glass fixed in panels with suitable locking arrangements including taking down of old existing steel ventilator with guard bars and making good disturbed surfaces of wall complete all as specified and directed. |
| 37 | S&F Framed work such as grills, gratings, etc with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walkways; railings; frame work of water tanks and similar work conforming to Fe290,Gde-E-165 complete all as specified and and directed. |
| 38 | M&L for preparation of new of previously untreated steel and Iron surface of any description, not otherwise described over 10 cm width or girth and applying two coats of Synthetic enamel paint over one coat of red oxide primer complete all as specified and directed. |
| 39 | Taking down chowkhats or frames with shutters (without taking off shutters from the frame) area exc 1.5 sqm but n exc 4 sqm each and removal from site including cutting holes for taking out hold fast or dismantling brick work/ stone work (holes cut and any other damage to jambs walls for taking out hold fast shall be finished identical to existing finish without extra cost to the Govt) complete all as specified. |
| 40 | M&L for fabrication and fixing of anodised powder coated aluminium door shutter fixed with rubber gasket, stopper, cleats, handles etc complete for aluminium frame of size 101.6 mm x 44.45 mm x2 mm and section of bottom and top rail iof section 114 mm x 44.45 mm x 2mm and lock rail shutter frame of 83 mm x 44.45 x 2 mm with and including panels of 5.5 mm thick plain/ forsted float glass, and with anodised aluminum snap beading of size 18.20 mm x 16.66 mm scred for fixing fully including all neceassary fittings and EPDM rubber packing each shutter shall be provided with two decorative type aluminium disc handle of 150 mm dia per shutter, 1 no heavy duty door shutter of 200 mm long aluminium tower bolt and 3 nos 125 mm long stainless steel butt hinges per shutter complete all as specified and as directed . |
| 41 | S&F brass 4 levers mortice lock, vertical type, size 100 mm complete all as specified and as directed . |
| 42 | S&F aluminium (extruded section) body door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed complete all as specified and as directed. |
| 43 | Taking down chowkhats or frames with shutters (without taking off shutters from the frame) area n.exc 1.5 sqm each and removal from site including cutting holes for taking out hold fast or dismantling brick work/ stone work (holes cut and any other damage to jambs walls for taking out hold fast shall be finished identical to existing finish without extra cost to the Govt) complete all as specified. |
| 44 | S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing on SI page No 156 of SSR Part-II completed. |
| 45 | S&F Solid PVC door frame of size 50mm X 47mm made out of 5mm plain colour PVC sheet reinforced with MS Square tube, supplying and fixing in opening as per specification and drawing on SI page No.160 of SSR Part-II completed complete all as specified and directed. |
| 46 | S&F 100 mm butt hinges stainless steel complete all as specified and directed. |
| 47 | S&F aluminium handles 150mm size cast type anodised complete all as specified and directed. |
| 48 | S&F 150 mm long Aluminium anodised barrel tower bolts complete all as specified and directed. |
| 49 | S&F in repair stainless steel curtain rod of 25 mm dia and thickness not less than 0.75 mm fixed with curtain rod holder and finials etc. complete all as specified and directed. |
| 50 | Use and waste of formwork to sides and soffits of, shelves, platform etc rough finished surfeces of concrete flat etc complete all as specified and directed. |
| 51 | M&L for TMT bar 10 mm dia and over cut to length, bent to shape required and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed. |
| 52 | Use and waste of formwork edge of concrete flats, treads breaks in floors, window cill, concrete railing openings in concrete walls floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls horizontal or sloping and similar work exc 10cm but n exc 20cm wide complete all as specified and directed. |
| 53 | M&L for RCC nominal mix type A1 1:1.5:3 using 20mm gradded stone aggregate Slabs supported on walls, beams and columns in floors, shelves, platform, lintel, deck slabs and the like complete all as specified and directed. |
| 54 | Demolition of cement concrete (un-reinforced) any description and in any position not otherwise specifically provided for complete all as specified and directed. |
| 55 | Demolition of reinforced cement concrete any description and in any position not otherwise specifically provided for complete all as specified and directed. |
| 56 | M&L for PCC 1:2:4 type B-0 (using 12.5mm graded agg) 25 mm thick (average) stone aggregate as in sub base, levelling course to receive floor topping complete all as specified and directed. |
| 57 | M&L for 75mm thick PCC (1:3:6) type C2 (using 40mm graded crushed stone aggregate) as in plinth protection, finishing cement concrete surface even & fair without using extra cement including filiing the joints with bitumen & sand in 2:1 proportion etc complete all as specified and directed. |
| 58 | M&L for PCC (1:3:6) type C-1 (using 20mm graded crushed stone aggregate) as in surface channel or drain including use of necessary from work for fair finished surface complete all as specified and directed. |
| 59 | S&F solid PVC wall Lining consisting of 5mm thick plain colour PVC sheet inclusive of solvent cement and fixing at site over and including on PVC frame 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive offixing on to wall to make PVC Frame as per specifications and drawing |
| 60 | S&F aluminium powder coated partitions made of the following specifications :-(Net external size of partition shall be measured). Following items shall be include in quoted unit rate.(a) Aluminium frame powder coated (minimum thickness of powder coating 50 micron) (Vertical and horizontal members) @ not exceeding 1.20 m distance both ways of hollow section 100 mm x 44 mm x 1.60 mm thick.(b) Lower portion of partition shall be fixed with 12 mm thick particle board fixed with suitable aluminium beading clips and EPDM beading (rubber) and all other accessories.(c) Upper portion of partition shall be fixed with 5 mm thick glass (as per user requirement) fixed with suitable aluminium beading clips and EPDM beading (rubber) and all other accessories.(d) Repair to the jamb, cills and all sides around the partition shall be include in the quoted unit rate. The repair finishes to match the existing surfaces like tiles, plastering, OBD etc. |
| 61 | Taking up or down GI 15mm bore pipe and connection including cleaning for refixing or removal from site complete all as specified and directed. |
| 62 | Taking up or down GI 20mm steel tubing and connections incl cleaning for refixing or removal form site complete all as specified and directed. |
| 63 | S&F 15mm bore pipe medium grade galvanised iron water tube concealed (including cutting chasing and making good) with all fittings laid in floors/ fixed to wall etc complete all as specified and directed. |
| 64 | Refixing old 15mm GI tubing and connections concealed in new or old position (including cutting chasing and making good) (walls, ceilling, floor etc) complete all as specified and directed.Note:- Serviceable GI tube Retrieved from above item No 63 shall be used under this item. |
| 65 | S&F 20mm bore pipe medium grade galvanised iron water tube with all fittings laid in floors fixed to wall etc complete all as specified and directed. |
| 66 | Refixing old 20mm GI tubing and connections in new or old position (walls, ceilling, floor etc) complete all as specified and directed.Note:- Serviceable GI tube Retrieved from above item No 64 will be used under this item. |
| 67 | S&F in repairs vitreous china under counter one piece wash basin, white, oval type, size 460x310x220mm including, CP waste coupling complete, waste pipe fixed with granite counter with RCC slab complete all as specified and directed.Make:- Prayag Cat part No. Niall-4793 or of Techno commercially equivalent model in other approved make. |
| 68 | S&F in repairs beveled edge mirror of size 600 x 450 mm, mounted on 6 mm thick AC plain building board or PVC board and fixed to wall on wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed. |
| 69 | S&F in repair 10 ltr capacity dual type PVC flushing cistern low level white colour including PVC connection, PVC flush pipe of required length complete all as specified and directed. |
| 70 | S&F in repair Vitreous china wash down water closet pan (pedesatal pattern) (EWC) white including plastic water closet seat cover closed pattern with flat bottom, and cover and mild steel chromium plated hinging divice etc complete |
| 71 | S&F in repairs Bib taps fancy type, brass chromium plated for 15mm bore pipe, screwed for iron pipes or for brass ferrule complete all as specified and dierected. |
| 72 | S&F Health faucet brass chromium plated suitable for 15 mm dia pipe with 1.25 meter long flexible tube and CP wall hook including making conncetions and fixed in position complete all as specified and directed. |
| 73 | S&F 15 mm bore fancy type bib taps long body (two in one) brass material, 15 mm bore single handle and wall flange with fancy chromium plated screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed. Make:- CERA Cat part No. F-1015163 or of Techno commercially equivalent model in other approved make. |
| 74 | S&F 15mm bore PVC Connection with PTMT nut of length 600 mm complete all as specified and directed. |
| 75 | S&F fancy type swan neck pillar taps, brass with capston heads, chromium plated, screwed down high pressure, with or without lettered hot or cold with long screwed shanks and fly-nuts, screwed for iron pipe 15mm bore complete all as specified and directed. |
| 76 | S&F in repair 15 mm bore angle cock CP with flage complete all as specified and directed. |
| 77 | S&F brass chromium plated tubular towel rail, 20mm dia and 0.80mm thick, D type, 60cm long between flanges complete all as specified and directed. |
| 78 | S&F in repair for 75 mm bore PVC (SWR) floor trap, plain with CP grating (with or without hole) including jointing with solvent cement complete all as specified and directed. |
| 79 | Taking down CI/PVC/AC soil pipe including fittings from wall, treches of any description complete all as specified and directed. |
| 80 | S&F 110mm bore PVC (SWR) pipes, type 'A', single socketed confirming to IS- 13592:1992) in any length with rubber ring joints laid in trenches or in floor complete all as specified and directed. |
| 81 | S&F 110mm bore PVC (SWR) pipes, type 'A', single socketed confirming to IS- 13592:1992) in any length with rubber ring joints fixed to wall complete all as specified and directed. |
| 82 | S&F 110mm bore PVC bends of any radius complete all as specified and directed. |
| 83 | S&F 110mm bore PVC (SWR) branch piece double (double 'Y') equal or unequal complete all as specified and directed. |
| 84 | S&F 110mm bore PVC (SWR) junction double (double 'T') equal or unequal complete all as specified and directed. |
| 85 | S&F 110mm bore PVC SWR vent cowl complete all as specified and directed. |
| 86 | S&F 75mm bore PVC (SWR) pipes, type 'A', single socketed confirming to IS- 13592:1992) in any length with rubber ring joints laid in trenches or in floor complete all as specified and directed. |
| 87 | S&F 75mm bore PVC (SWR) pipes, type 'A', single socketed confirming to IS- 13592:1992) in any length with rubber ring joints fixed to wall complete all as specified and directed. |
| 88 | S&F 75 mm bore PVC (SWR) bends of any radius with acess door complete all as specified and directed. |
| 89 | S&F 75 mm bore PVC (SWR) junction single (Single `T') equal or unequal complete all as specified and directed. |
| 90 | S&F 75 mm bore PVC (SWR) branch piece single (Single `Y') equal or unequal complete all as specified and directed. |
| 91 | S& in repair vitreous China Urinal, Half stall type, white (including flush pipe and waste pipe) complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe complete all as specified and directed. |
| 92 | S&F urinal spreader of CP brass for fixing with 15 mm dia pipe complete all as specified and directed. |
| 93 | S&F 500 ltrs capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with polythene foam insulation as intermediate layer and closed top) double layer ISI marked (IS: 12701 : 1996), hoisted and fixed in position all as specified in SSR Part I including inlet, outlet and over flow connections etc including dismantling existing tank complete as specified and directed. |
| 94 | S&F 20 mm bore ball valves high pressure of PTMT with epoxy coated aluminium rod & highdensity plastic ball screwed for iron pipe and fixed as required to use reducer and check nut complete as specified and directed. |
| 95 | S&F in repair 20mm bore Gun metal globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and dierected. |
| 96 | M&L for cement concrete (1:3:6) type C-1 (using 20 mm graded crushed stone aggregate) as in roof kerbs or mud stops, rounded or chamfered on edges complete all as specified. |
| 97 | Removing building materials and debris (other than excavated earth) to a distance of 5 KM inside MD Land at locations specified including loading and dumping/ leveling at the destination complete all as specified and directed. |
| 98 | M&L for water proofing treatment to sunken floor with the following course of treatment/ specification: (i) Cleaning top surface of floors /slabs and laying 50 mm thick (avg) PCC of grade M10 (Nominal mix) , mixed with WPC as per manufactrrer's instruction laid in slope 1:20 towards spouts including coveting corners (ii) 15 mm thick plastering in CM (1:4) on sides mixed with WPC as pe rmanufacturer's instruction. (iii) Applying 1st layer of slurry @ 0.488 kg / sqm mixed wth acrylic based polymer modified cementious compound @ 0.253 kg /sqm. This layer shall be allowed to air cured for 4 hrs. (iv) Applying 2nd layer of slurry @ 0.242 kg/sqm mixed with accrylic based polymer modified cementenous compound @ 0.126 kg/sqm. This layer shall be allowed to air cured for 4hrs followed with water curing for 48 hrs.(v) Applying a coat of industrial bitumen 85/25 penetration @ 1.50 kg/sqm on plastered and concrete surfaces (vi) Providing 150 micron thick polyutethene paint in two coats (each of 75 micron) measured dry on dry surface over a coat of PU primer including preparation. (Make of PU primer - Dek guard EP -302 of M/S Fosroc or equivalant approved brand. Make of PU paint - Dek guard PU or equivalant approved brand. (vii) 2 Nos 32mm bore GI medium grade 450mm long spout, to be provided through external wall to drainout accumulated water. (viii) Sunken floor shall be tested for water tighness by filling water for 72 hrs before and after treatment work is carried out and ensure that no leakage /seepage exists (ix) Sunken portion shall be filled with lean concrete of grade M7.5 stone agreegate.Note: The top floor area of WC/Bath shall only be measured and paid. |
| 99 | M&L for reinforced cement concrete (nominal mix) type A1 1:1.5:3 (using 20mm graded crushed stone aggregate) as in chajjas etc complete all as specified.Note: Reinforcement and formwork shall be measured and paid for separately. |
| 100 | Use and waste of formwork to Formwork to chullah hoods, chajjas, troughs and similar items including edges, etc. for flat rough finished surfaces of concrete complete all as specified |
| 101 | M&L for preparation of old wooden surface of any description over 10cm width or girth and applying one coats of synthetic enamel paint complete all as specified and directed. |
| 102 | M&L for preparation of old steel surfaces of any description over 10cm width or girth and applying one coats of synthetic enamel paint complete all as specified and directed. |
| 103 | Demolition of cement concrete (un-reinforced) in ground floor and paving not exc. 15 cm thick (Below or above ground level) complete all as specified and directed. |
| 104 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc for taking credit ( credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc complete all as specified and as directed. |
| 105 | M&L for point wiring complete with 1.5 Sqmm multistranded copper conductor single core PVC insulated, IS 694 unsheathed FR-LS cable 1100 volts grade (ISI marked) with proper colour coding drawn through and including non-metallic rigid PVC medium grade conduit not less than 20mm dia and conduit accessories (ISI marked) concealed in wall/fixed to roof, ceiling etc including provision of 1.5 Sqmm PVC insulated multistranded unsheathed copper conductor cable FR-LS (ISI marked) as earth continuity conductor connected to common earth dolly, fabricated sunken terminal box made out of GI sheet steel not less than 1.22 mm thick for boxes duly painted with anticorrosive paint, concealed in walls with bakelite/plastic laminated sheet top cover fixed with cadmium plated iron screws for housing switches, socket outlets, fan regulators etc duly earthed including cutting chases of existing wall for conduits and sunken for boxes and making good to the disturbed surface of wall/floor and matching with existing specifications all as specified and as directed for the following :- |
| 106 | (a) One light point controlled by one way switch 5/6 amps. |
| 107 | (b) One ceiling fan/Exhaut fan point controlled by one way switch 5/6 amps. |
| 108 | (c) One socket out let 5/6 amps point on the same board |
| 109 | (d) One socket out let 5/6 amps point on the independent board |
| 110 | All as per item No 115 above but wiring with 2.5 sq mm single core copper conductor for one socket out let 15/16 amps point on the independent board complete all as specified and directed. |
| 111 | S&F switch piano flush type 5/6 amps single pole one way complete all as specified and directed. |
| 112 | S&F socket 2 in 1, 5 Pin, 5/6 amps, white ivory finish flash type complete all as specified and directed. |
| 113 | S&F of socket outlet 2 in 1, 5 Pin, 5/15 amp, multipurpose 230 volt flash type complete all as specified and directed by Engr-in-Charge. |
| 114 | S&F switch piano flush type 15/16 amps single pole one way complete all as specified and directed. |
| 115 | S&F Ceiling rose, surface type with back plate, three terminal /PVC/ polycarbonate, isolated body complete all as specified and directed. |
| 116 | S&F of stepped type electronic fan regulator 120 Watt 2 module suitable for 1200/1400 mm sweep energy saving fans,ISI marked complete all as specified and directed. |
| 117 | S & F Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and directed. |
| 118 | S&F LED lights fitting 1x 20W, 220V AC decorative box type with driver,IP 20, class I, wall/ surface mounted, integrated type with PC batten integrated high efficiency electronic driver and surge suppressor of 4KV or more, luminaire efficiency not less than 120 lumens/watt, power factor not less than 0.90, CRI 80, THD 10%, operating range - 140 to 270 V, 50 Hz fixed with 02 Nos of PVC round/ square blocks, screws etc connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete. complete with all accessories internally prewired and connecting up complete all as specified. |
| 119 | Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete integrated high efficiency electronic driver and surge suppressor of 4KV or more, luminaire efficiency not less than 100 lumens/watt, power factor not less than 0.90, CRI 80, THD 10%, operating range - 140 to 270 V, 50 Hz for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size completeall as specified and directed |
| 120 | Supply and fix Decorative wall light City 1fixture made up of Polycarbonate, suitable for 9 W retrofit LED lamp B22 bas eand making connection complete all as specified and directed. . |
| 121 | S&F LED Bulk Head lights fitting 1x 9/10W, 220V AC integrated high efficiency electronic driver and surge suppressor of 4KV or more, luminaire efficiency not less than 120 lumens/watt, power factor not less than 0.90, CRI 80, THD 10%, operating range - 140 to 270 V, 50 Hz fixed etc connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete. complete with all accessories internally prewired and connecting up complete all as specified. |
| 122 | S&F Sheet metal enclosure for 4 way Distribution Boards (DB’s), IP-43 double door, Tripple pole & neutral with 200 amps rated bus bar, IP-20 protection with blanking plates complete including necessary taking down all as specified and directed. |
| 123 | S&F MCB, Triple pole & neutral, 32 amps, 415 volts, ‘C’ curve, 10 KA all complete including taking down the old one complete all as specified and directed by Engr-in-Charge. |
| 124 | S&F Sheet metal enclosure for 8 way Distribution Boards (DB’s), double door, single pole & neutral with 200 amps rated bus bar, IP-20 protection suitable for fixing MCB\\"S/lsolators complete including provision of blanking plates as required and taking down the old one complete all as specified and directed by Engr-in-Charge. |
| 125 | S&F MCB, Single pole & neutral 6 to 32 amps, 240 volts, ‘C’ curve, 10 KA all complete including taking down the old one complete all as specified and directed by Engr-in-Charge. |
| 126 | S&F MCB, Single pole, 6 to 32 amps, 240 volts, ‘B’ curve, 10 KA all complete including taking down the old one complete all as specified and directed by Engr-in-Charge. |
| 127 | Material and labour for concealed sub-main wiring alongwith earth wire of size of 2 x 6.0 sq. mm + 1 x 6.0 sq. mm earth wire, ISI marked, FRLS, PVC insulated, multi stranded, copper conductor, single core cable drawn through and including PVC rigid conduit (medium grade) of of size not less than 20 mm with all fittings and accessories ISI marked including cutting chases for conduits & making good to walls, floors etc complete, including taking down old unsv aluminium submain wiring all as specified and as directed. NOTE : Two runs of 4 sqmm conductor for main and one run of 4 sqmm conductor as earth wire with proper colour coding including one run run of PVC conduit shall be measured as one unit length. Connections of cables wit MCBs or bus bar shall be done through appropriate size brass/ copper thimbles |
| 128 | Taking down carefully Ceiling/exhaust fan from its original position and M&L for painting of ceiling fan complete, in situ with synthetic enamel paint by spraying including filling cavities with filler one coat after cleaning all dust etc, all as specified and as directed.and refixing / hanging after B/R plaster work complete all as specified and directed. |
| 129 | M &L for Earthing complete with GI earth plate electrode 600x600x6mm thick buried directly in ground (Earth pit not less than 2.25M deep below normal ground level) with top edge of the plate not less than 1.5m below normal GL. Connected to galvanized earth lead wire 4mm dia by means of nut, bolt, check nut and washers including necessary excavation and earth work in soft/loose soil, GI protection pipe light grade 15mm bore for protecting the GI wire mesh funnel alternate layer of charcoal dust, and salt PCC pit 1:3:6 type C1 using 20mm graded stone aggregate and 50mm thick RCC 1:2:4 type BO using 20mm graded stone aggregate cover re-inforced with 8 mm dia MS TMT bars 80mm C/C both ways complete all as specified and shown in Electrical plate No.3 SSR part-1 and connected to the earth point and testing complete including taking out the old one complete all as specified and directed by Engr-in-Charge. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail