| 1 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. Nominal concrete 1:4:8 or leaner mix (including equivalent design mix) |
| 2 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:5:10 (1 cement : 5 coarse sand (zone-Ill) derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from naturalsources) |
| 3 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 (1 Cement : 3 coarse sand (zone-Ill) derived from natural sources :6 graded stoneaggregate 40 mm nominal size derived from natural sources) |
| 4 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : 6.4.1 Cement mortar 1:4 (1 cement :4 coarse sand) |
| 5 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. |
| 6 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. |
| 7 | 12 mm cement plaster of mix : 1:4 (1 cement: 4 fine sand) |
| 8 | 15 mm cement plaster on the rough side of single or half brick wall of mix : 1:4 (1 cement: 4 fine sand) |
| 9 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 10 | Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. One coat |
| 11 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : One or more coats on old work |
| 12 | Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge. With cement mortar 1:4 (1 cement : 4 fine sand) |
| 13 | Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. |
| 14 | Providing and applying cement based putty on old work (Birla, jk or equivalent) to the required finish complete in all respect and to the entire satisfaction of Engineer-in-charge. |
| 15 | Repair of deteriorated RCC Balconies, Beams, Walls, Ceiling, Column or other concrete surface having exposed rusted bars consisting of following operations (a) chipping of concrete surface 25mm thick average depth afterwards remocal of loose concrete and exposing the steel bars. Cleaning the surface properly to remove dust particles and rust from the steel bars. (b) Moistening the surface properly and applying arcylic polymer (acrocrete/ pidilite/ mastercrete or its equivalent) coating mixed with cement for proper bonding of old and new concrete in two coats 0.2kg per 1kg of cement. (c) Providing and fixing chicken mesh of standard size and 26 guage with steel reinforcement by using binding wire and nails complete. (d) Proving and placing of cement concrete l:11/2:3 having average thickness 1\\" (3/4\\" to 11/4\\" thick) mixed with arcylic polymer admixture @ 1kg per bag of cement and waterproof agent @ 400ml per 2 bags of cement including finishing the surface complete in all respect as per the direction and to the entire satisfaction of Engineer-in-Charge. |
| 16 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer and two coats of snthetic enamael paint all complete. (Based on DSR 10.2) |
| 17 | 40 mm thick fine dressed stone flooring over 20 mm (average) thick base of cement mortar 1:5 (1 cement :5 coarse sand) with joints finished flush. Red sand stone |
| 18 | Providing and fixing 15 to 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels. (GRANITE). Please Enable Macros to View BoQ information |