| 1 | Taking down tarfelt with cement plaster from roof surfaces and lowering and removing the same to a distance exc. 500m and n. exc. 900m incl roughening of old concrete suirface of roof by wire brushing and cleaning the surface to remove all loose dust etc complete all as specified and as directed. |
| 2 | Demolition of precast concrete block/brick walling built in cement mortar of any description etc complete all as specified. |
| 3 | Taking down cement plaster any description on brick or stone wall etc including racking out joints hacking for key scrubbing down with water etc. |
| 4 | Dismantling wrought iron or mild steel work of any description not otherwise provided for grils.rails etc |
| 5 | Demolition of cement concrete of any description in any position. |
| 6 | M&L for 10mm thick screed bed or bedding layers in cement mortar (1:4) in order to maintain proper slope over existing roof surfaces for applying single component acrylic polymer modified, finished even and smooth without using extra cement mixed with water prrofing compound complete all as specified and as directed. (NOTE : WPC shall be measured and paid separately under relevant item of this Schedule 'A'). |
| 7 | M&L 25 mm thick PCC 1:2:4 type B0 (Using 12.5 mm graded stone aggregate) mixed with water proofing compound and laid on RCC slab as base layer for roof treatment roughening the top surface of concrete by using broom sticks while the concrete is green complete all as specified and as directed.(NOTE : water proofing compound paid separately under relevant item of this Schedule 'A'). |
| 8 | M & L water proofing treatment to RCC roof slab including parapet comprising of the following course of treatement / specified from bottom to top (a) Applying Bituminous primer @ 0.40 Ltr per Sqm over plastered surfaces of roof including parpet surfaces. Bituminious primer shall be 'Tar Mastic' manufactured by M/S STP LTD or 'EMW FLATE' manufactured by M/S Texsa India Ltd. (b) Over the priming coat laying one layer APP based polymeric membrance of approved manufacturer, 3 mm thick of weight not less than 3.60 Kgs/Sqm reinforced with non woven polyester fabric weight not less than 160 gms per Sqm. Polymeric members shall be taken to a height of 60cm (minimum) and then inserted inside the groove of parapet wall and shall be finished by a membrance flashing. (c) Application of two coat of bituminous aluminium paint over the polymeric membrane after necessary preparation and cleaning. Note :- (i) Laying APP based polymeric membrance shall be done by torch on method or as per manufacturers instructions. (ii) A minimum overlap of 100mm shall be made at the end and 75mm shall be made at the sides of the polymeric membrance respectively and sealed all ovelaps and joints as per Manufacturers instructions. (iii) APP based polymeric membrance shall be \\"SUPER THERMOLAY\\" manufactured by M/S STP LTD or MOPLY FP manufactured by M/S Texsa India Ltd. |
| 9 | M & L PCC (1:2:4) type B1 (20mm graded aggregate) as in roof kerbs, slightly rounded or chamfered on edges, mixed with water proofing compound 200 ml per beg of cement or as per manufacturer instructions finished even and smooth on exposed concrete surface without using extra cement all complete as specified and as directed. (Note: Water proofing compound shall be measured and paid perarately under relevant item of schedule 'A'). |
| 10 | M&L for cutting out cracks to 'V' section (shape) in existing roof slab terracing cleaning out and filling solidely with cement and sand mortar (1:1) complete all as specified and as directed. |
| 11 | Plain Cement Concrete Type B1 1:2:4 (using 20 mm graded stone aggregate) in water tank platforms,filling and mass concrete. |
| 12 | Taking up or down steel water tubings and fittings etc of Bore tubing 20mm, complete and making good disturbed surfaces of walls/ceilings etc complete all as specified and as directed. |
| 13 | M & L for steel tubing medium grade,galvanised fitting fixed complete to walls and ceiling or floor of Bore tubing 20mm dia,complete all as specified and as directed. |
| 14 | Al as per item No 13 here-in-above but fixing only |
| 15 | S & F in repair 500 ltrs rotational moulded polyethelene water storage tanks (cyclindrical vertical with closed top) incl connecting up pipes securing access covers etc as specified and as directed. |
| 16 | S&F 20 in reapir mm dia PVC ball cock (PVC float valves) complete high pressure with epoxy coated aluminum rod and high density plastic ball screwed for iron pipe and fixed as required to use reducer and check nut. |
| 17 | Disconnecting existing tanks of capacity exc 250 Ltrs and n. exc 500 Ltrs, setting aside (or lowering if required) for repairs with all necessary fitting as required, cleaning, etc. and hoisting if required reconnecting and re-fixing in same position after cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes, etc complete all as specified and directed. |
| 18 | S&F Framed work such as grills,gratings, etc with ends of bars shouldered and/or riveted,or forged into spikes; framedguard bars; barred iron doors; ladders; framed balusters; walkways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 |
| 19 | M & L for providing plain cement concrete type C-1, 1:3:6, (using 20 mm graded stone aggregate), as in copings, bed block for filing hollow space of steel chowkhats, fixing of hold fast, kneelers, apex stones, bed plates, water troughs and the like including weathering, Copping, slightly rounded or chamfered angles & throating as directed including necessary form work as required complete all as specified and directed. |
| 20 | M&L brickwork with sub class B bricks straight or curved on plan exc 6mtr mean radius built in cement mortar 1:6 by using old size bricks complete. |
| 21 | Supply only liquid water proofing compound. |
| 22 | S&F in repair for PVC (SWR) (Bore of pipe 110mm) pipes single socketed, in any length with rubber ring joints fixed to walls with necessary clamps, bolts etc complete all as directed by Engr-in-Charge. |
| 23 | S&F in repair for PVC (SWR) bends any radius fixed to PVC Pipes/Steel Gutters etc complete all as directed by Engr-in-Charge (Bore of pipe 110mm) |
| 24 | M&L for rendering 20mm thick in cement mortar 1:4 in two layers of 10mm each using WPC in finishing layer on brick or concrete surfaces finished even & fair (WPC for finishing layer will be paid seperately as supply only). |
| 25 | M & L for preparing new Plastered surfaces of walls and finishing the walls with Acrylic smooth exterior paint of required shade : New work (Two or more coats applied @1.67 Ltr/10 Sqm over and including priming coat of exterior primer applied @ 2.20 Kg/ 10 sqm) over a coat of 2 mm thick brila white care wall putty.Make of Weather proof exterior acrylic emulsion and primer : Asian Apex Ultima/Berger weather coat long life 10 NOTE :- (i) Surface where Wall care putty to be provided shall be cleaned by vacuum suction system to remove all the dust. (ii) Wall care putty shall be mixed in multipurpose mixer machine. Putty shall be applied with Putty Sprayer.(iii) Weather coat shall be applied with Auto Roller, which consists of pump attached to the roller head and ensures a uniform feed of paint to the roller and also ensure any spillage on the floor and windows as in the case of a conventional painting methodology. Roller in coats comprises of vertical strokes upward and downward which together constitute one coat. A uniformly finished surface without patches, roller marks etc shall be obtained.(iv) The work shall be carried out through authorized applicator of the manufacturer. Contractor shall submit details of applicator for approval of GE prior to execution. |
| 26 | M&L for applying two coats of synthetic enamel paint over a coat of red oxide primer including preparation of new steel surface over 10cm width or girth Please Enable Macros to View BoQ information |