| 1 | Dismantling Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings in roof covering. |
| 2 | Demolition of reinforced cement concrete Roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work including cutting of reinforcement bars to facilitate demolition complete all as specified and directed |
| 3 | Dismantling wrought iron or mild steel work of any description not otherwise provided for. |
| 4 | Dismantling of cast iron or reinforced concrete drain pipes, jointed in cement mortar and taking out of trenches, upto 150 dia size |
| 5 | Dismantling water tanks and removing to store of capacity exc 250 & n.exc 500 ltrs complete all as all as specified and directed. |
| 6 | Taking down 15 mm GI tube complete all as sepcified & as directed. |
| 7 | Taking down 25 mm GI tube complete all as sepcified & as directed. |
| 8 | Taking down eaves Gutters rain water pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc, including cleaning or refixing or removal to store (measured overall as fixed along the centre line over fittings and accessories) complete all as specified and direceted. |
| 9 | Demolition of Stone slabs and tiles of any description or thickness in floors, aprons etc. laid bedded and pointed in any mortar |
| 10 | Taking down chowkhats or frames area exc. 1.50 Sqm but not exc. 4.00 Sqm each with shutters (without taking off shutters from the frames) complete all as specified and directed. |
| 11 | Taking down chowkhats or frames area not exc. 1.50 Sqm each with shutters (without taking off shutters from the frames) complete all as specified and directed. |
| 12 | Demolition of stone/boulder work built in cement mortar or cement lime mortar complete all as specified. |
| 13 | Demolition of cement concrete of any description and in any position not otherwise specially provided for. |
| 14 | Earth work in excavation by mechanical means All kind of soil (Hydraulic excavator) means over areas (exceeding 30 cm in depth,1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5m, as directed by Engineer-in-charge out in all kind of soil |
| 15 | Earth work in excavation by mechanical means (Hydraulic excavator)/ in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.as directed by Engineer-in-charge out in hard rock where blasting is prohibited |
| 16 | Returning, filling in including spreading levelling watering well ramming in layers not exc 25 cm each layer in soft/loose soil. |
| 17 | Removal of excavated soft soil to a distance exc 250 m but n.exc 500 m and depositing where directed. |
| 18 | Removal of excavated rock material to a distance exc 250 m but n.exc 500 m and depositing where directed. |
| 19 | M&L for plain cement concrete M10 (1:3:6) type C-2 (using 40 mm graded stone aggregate ) as in foundation, filling & mass concrete. |
| 20 | Use & waste of Formwork (square, reactangular or polygonal ) to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work for rough finished surface of concrete; vertical or to batter. flat surface |
| 21 | Use & waste of Formwork (square, reactangular or polygonal ) to sides of pillars, posts, struts, piers, columns and stanchions for fair finished surface. |
| 22 | Use & waste of Formwork to sides and soffits of floor or roof beam,beam haunchings,girders,bressum-mers,lintels,band,cantilevers,coping,shelves including supports,overhangs, etc, also splays between floors and beam for fair finished surface. |
| 23 | M&L for Mild steel CRS TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips. |
| 24 | M&L for mild steel CRS TMT bars 5 mm dia and over upto and over upto and including 10 mm dia in stirrups ,spaces and binders. |
| 25 | M & L for RCC M-30 (Design Mix) in foundation incl rafts, footings, foundation ,plinth beam underreamed piles and mass concrete all as specified & directed. |
| 26 | M & L for RCC M-30 (Design Mix) in Columns, pillars, piers, posts and struts all as specified and directed. |
| 27 | M & L for RCC M-30 (Design Mix) in beams, cantilevers,bressumers,lintels and coping over 1.5m span as specified and directed. |
| 28 | M & L for Pre-cast cement concrete block masonry with solid block of PCC type C1,(1:3:6), using 20 mm graded stone aggregate , exc. 10 cm in width and setting in CM (1:6). |
| 29 | M&L for 12 mm thick modified polymer ready mix plaster to surface of bdry wall finished even and fair, complete all as specified. |
| 30 | S & F for Hand rails, half round or other steel section or core for wooden hand rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embedding in concrete and screwing etc. wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 as directed. |
| 31 | S & F Framed work such as grills, gratings, etc.. with ends of barsshouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walkways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165 |
| 32 | S&F plates (plain or chequred) square cut are nothced (ordinary) and counter sunk, forming holes and fixed as directed including necessary welding as required as in stairs, cable duct covers etc all as specified and directed. |
| 33 | M&L for 18-20 mm thick Granite (of any type) work (table rubbed and polished) for wall lining (veneering to wall) 12 mm thick in cement mortar (1:3) and pointing with white cement (1:2) using marble dust with admixture of pigment to match with shade of granite. |
| 34 | M&L painting on steel surface over 10 cmwidth or girth including preparation of surface and applying two coats of synthetic enamel paint over a coat of red oxide primer. |
| 35 | Formig 'V' grooves in plaster not exceeding 10mm deep and not exceeding 10mm on face. |
| 36 | M&L for brocken glass coping on top of wall in cement mortar 1:3. |
| 37 | S & F Galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured). |
| 38 | S & F Bitumen dip Concertina coil, punched tape 2.60mm dia high tensile spring steel wire, dia of coil 610mm, when stretched the length shall be 6m in one coil and tied to barbed wire with and incl provision of steel slips @ 5 clips spiral in one row complete without coating complete all as specified and directed by Engr-in-charge. ( 275 Rm =275 x 2.051kg/Rm approximate = 565 kg) |
| 39 | M &L for preparation of newly plastered surfaceof wall and applying two coats of cement base paint over a coat of alkali resistant primer |
| 40 | Dismantling barbed wire of any description |
| 41 | Dismantling steel posts or structs any section including taking out embedded portion from concrete, brick masony etc. |
| 42 | Taking down carefully aluminum/copper point wiring (light,fans,socket etc) complete incl battens and fittings such as switch, ceiling rose,light fittings, regulaters, socket etc and making good disturbed surface of wall/floor etc complete all as specified. |
| 43 | M&L for taking down Submain wiring complete all as specified and as directed. |
| 44 | M&L for taking down of light fittings any type complete all as specified and as directed. |
| 45 | M&L for taking down of Ceiling Fan/Exhaust fan and deposited to MES storeyard complete all as specified and as directed. |
| 46 | M&L for taking down of MCB any size and any type complete all as specified and as directed. |
| 47 | M&L for taking down of MCB DB complete all as specified and as directed. |
| 48 | M&L for taking out/ Dismentaling of old Street Light/ Flood Light/ Bldg light fittings after disconnect from power supply and all connection complete. |
| 49 | M&L for taking out/ Dismentaling of old steel tubular swaged poles type 410SP-31(9.0 meter long) Swan Neck Type complete and its accessories after disconnect from power supply and dismental from foundation dresssing of ground surface complete all as specified and directed. |
| 50 | M&L for taking out of old UG XLPE Cable 16 Sqmm 4 Core after disconnect from power supply and disconnect of all connections complete. Please Enable Macros to View BoQ information |