| 1 | Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: Garrison Engineer (AF) Gorakhpur Name of Work:REPAIR/MAIN OF ROOF, CHAJJA, PLASTERING, ROOF TREATMENT, FLOORING, SANITARY FITTINGS, AND OTHER CONNECTED WORK IN TECH AREA AT AF STN GORAKHPUR. Contract No.: GE(AF)/GKP/E-06 OF 2026-27 File No.9444/E8 Serial Page No.15 Name of the Bidder/ Bidding Firm / Company : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Sl.No. Description of items Item Code / Make Quantity Units Estimated Rate inRs. P Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e. DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit, if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT Without Taxes inRs. P TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words |
| 2 | Demolition of brick work or stone/ boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars etc but excluding ashlar facing dressed stone work and precast concrete articles complete all as specified and directed. |
| 3 | M&L for brick work with subclass 'B' brick straight or curved on plan 6m mean radious built in CM (1:4) etc as directed . |
| 4 | Taking down cement or cement lime plaster any description incl racking out joints, hacking for keys, scrubbing down with water etc complete all as specified and directed. |
| 5 | M&L for rendering 15mm thick in cement mortar 1:4 on fair faces of brick masonry or concrete surfaces of walls, chajja, fins facia etc upto 3 storie height mixed with water proofing compound (ISI marked) @ 3% by weight of cement or as per manufacturer’s instructions, finished the surface fair and even (without using extra cement), complete all as specified. Note 1: - Supply only water proofing compound shall be measured and paid for separately. |
| 6 | Supply only integral water proofing compound (ISI marked) complete all as specified and directed. |
| 7 | M & L for rendering 15 mm thick in cemnet mortor 1:6 on fiar faces of brick work or concrete surfaces & finish the surface fair and even (without using extra cement), complete all as specified. |
| 8 | M&L for rendering 5 mm thick in cement mortar 1:3 on concrete surfaces in ceiling,finished even & smooth without using extra cement complete all as specified. |
| 9 | M&L for preparing newly plastered surfaces of wall and applying two coat of exterior emulsion paint camouflage pattern over one coat of primer and 2mm wall care putty complete all as specified and as directed by Engr-in-Charge. |
| 10 | M & L for Preparing new plastered or unplastered surfaces of wall and applying two coats of distemper oil emulsion, white or tinted over & over a coat of alkali priming coat and 2 mm thick wall care putty, complete all specified and directed |
| 11 | M & L for preparation of new plastered surfaces of ceiling and applying two coat of white wash complete all as specified and directed. |
| 12 | S&F in repair Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all specified and directed |
| 13 | S&F in repair 1st class Hard Wood Beads, straight (any size) for glazed or gauzed joinery, renewed, including mitres etc. complete all as specified and directed. |
| 14 | Hacking out old broken glass (any thickness, size, quality or escription) from wooden/metal frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads complete all specified and directed |
| 15 | S&F 3mm thick sheet glass ordinary quality and galzing with oil putty in square n. exc 0.5 sqm in each panel complete all specified and directed |
| 16 | M&L for 3mm thick Figured glass, pin head type and glazing with oil putty in squares n exc 0.5 sq. m in each pane complete all specified and as directed. |
| 17 | M&L in repairs powder coated aluminium doors (sliding/hanging type) with frame size 101.60X44.45X 2.00 mm thick and shutter aluminium anodised and top rail 47.62X 44.45 X 1.50mm and style 47.5 x 44.5 x1.5 mm , lock rail 83.50X 44.45 X 1.50 mm and bottom rail150.00X 44.50 X 2.50 mm and stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture1.4mm incl necessary aluminium fittings like aluminium butt hinges 04 Nos , aluminium handles 150mm 02 Nos, aluminium tower bolts 200mm 01No, mortice lock 4 lever MS, hydraulic door closer of suitable capacity 01 No, aluminium door stopper 01 Nos, jointing cleats, glazing cleats, rubber packing , anodised aluminium shape beading, screws etc with paneling in two parts with 12mm thick prelaminated particle board in lower panel and 5mm thick tinted glass in upper panels incl all fittings& fixture complete all as specified and directed. |
| 18 | M&L in repairs powder coated aluminium (sliding/ hanging type) windows/ventilator with frame size 60x40x2.00mm thick and shutter with section bearing bottom 25x18x1.50, top 39.4x17.7 X1.50 mm ( suitable for moving over three track fixed over top of frame work , top and side section of size 61.6 x 31.75x1.5mm and bearing bottom track of size 61.6x 31.75x1.5mm or fixing with hinges steel wire cloth 0.36mm nominal dia of wire and average width of aperture1.4 mm including necessary aluminium jointing cleats, glazing cleats, rubber packing anodised shape beading, screws etc with 4 mm thick tinted/ plain glass in panels incl anodised aluminium grill with all fittings & fixture complete all as specified and directed . |
| 19 | Repair/easing/readjusting of aluminium door/ window shutters by taking down shutters from frame and dismantling members of shutters like, glass, rails and style by necessary cutting, grinding of members etc and refixing same including rubber gasket, hinges, handle screws etc complete all as specified and directed. |
| 20 | S&F in repair mortice lock of mild steel vertical type of size 150mm with 6 levers fixed to wooden/ aluminum doors complete all as specified and directed. |
| 21 | S&F in repair double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless stell cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed complete all specified and directed |
| 22 | S&F in repair door closer hydraulically regulated, aluminium (extruded section body )designation No. 2, universal type, suitable for door shutters of 701 to 850 mm in width and of weight between 36 to 60kg complete all specified and directed. |
| 23 | S&F 15 mm bore GI tubes, medium grade galvanised, with all fittings and fixed complete to walls and ceilings or laid in floors or concealed including taking up or down steel tubing and connections including cleaning for re-fixing or removal to store complete all as specified and directed. |
| 24 | S&F 20 mm bore GI tubes, medium grade galvanised, with all fittings and fixed complete to walls and ceilings or laid in floors or concealed including taking up or down steel tubing and connections including cleaning for re-fixing or removal to store complete all as specified and directed. |
| 25 | S&F in repairs Bib taps 15 mm bore brass, chromium plated, fancy type with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed. |
| 26 | S&F in repairs 15 mm dia brass angle cock fancy type, with capstan head chromium plated screwed down high pressure with or without lettered with long screwed shank and fly nut screwed complete all as specified and directed. |
| 27 | S&F in repairs brass chromium plated two way angle cock, of 15 mm bore complete all as specified and directed. |
| 28 | S&F in repairs chromium plated shower roses with or without swivel joints, any size incl fixing to steel pipe or union complete all as specified and as directed. |
| 29 | S&F in repairs 15mm bore pillar tap fancy type cast copper alloy chromium plated screwed down high pressure with or without lettered 'Hot' or 'Cold' with long screw shanks screwed for iron pipe or union complete all as specified and as directed. |
| 30 | S&F in repairs 15mm bore dia Brass CP central hole mixer for mixing hot & cold water screwed down with PVC & CP connection on WHB complete all as specified and directed by Engineer-in-Charge. |
| 31 | S&F in repair 32/40 mm spring type PVC waste pipe fixed to WHB & Sink etc complete all as specified and directed ( Note minimum length of each pipe should more than 0.70RM) complete all specified and directed |
| 32 | S&F in repair 600X450 mm beveled edge mirror of selected quality glass 5.5 mm thick mounted on and including 6 mm thick AC building board or commercial plywood and fixed with two nos hanging clips complete all as specified and directed. |
| 33 | S&F in repair Vitreous China wash down water closet pan (pedestal pattern, with EWC including p or s trap ,seat cover , including connection to trap /drain and to flushing pipe anti syphonage pipe etc complete including making good floorcomplete all as specified as directed. |
| 34 | S&F in repair vitreous china squating pan orissa pattern size 580X 440mm white with intregal foot rest complete including lime concrete(excl flushing cistern and flush pipe) but connecting to flushing pipe, anti-symphonage pipe etc complete fixed in repair complete all as specified as directed. |
| 35 | S&F in repairs Vitreous china WHB, white, flat back, of size 550 x 400 mm including brackets, waste coupling 32mm, and waste Pipe, 32mm complete all as specified and directed. |
| 36 | S&F in repair vitreous china Urinal, half stall type, white (excluding flushing cistern, flush pipe and waste pipe) with urinal spreder complete all as specified and as directed by Engineer in Charge. |
| 37 | S&F in repair PVC valveless, syphonic action type flushing cistern complete with syphon handle lever float valve and PVC bend incl connecting to ITWC/ETWC and fixing on walls with brackets complete all as specified and as directed by Engineer in Charge. |
| 38 | S&F in repairs Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified. |
| 39 | S&F in repairs brass chromium plated tubular towel rail 20mm dia 600 mm long, fixed complete all as specified and as directed. |
| 40 | M & L for Non-skid coloured ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors/skirting etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed bed in CM (1:6) including dismantling of tiles, complete all as specified and directed. |
| 41 | M & L for Non-skid coloured ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors/skirting etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed bed in CM (1:6) including dismantling floor, hearth or wall tiling including dismantling of tiles, complete all as specified and directed. |
| 42 | M&L for Glazed ceramic coloured tiles 350x 250x 7mm/ 450X 350X 7mm thick, laid on vertical surfaces such as skirting, dados and risers to steps etc laid over 10mm thick cement plaster in CM (1:4) set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles includingdismantling of tiles, complete all as specified and directed. |
| 43 | M&L for doublecharged Vitrified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.36 sqm but not exceeding 0.42 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed in CM 1:6 including dismantling of tiles, complete all as specified and directed. |
| 44 | Dismantling of Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings all as specified and as directed. |
| 45 | S&F of Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws all as specified and as directed. |
| 46 | S& F of Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws all as specified and as directed. |
| 47 | Dismantling of structural steel work including doors, gates but excluding framed truss etc complete all as specified and directed. |
| 48 | M&L for roof trusses (Framed, purlins or rafters of Fe 410W (Grade E-250 quality A) including distance pieces and cleats complete all as specified and as directed. |
| 49 | M&L for preparation of new or previously untreated surfaces of steel of any description, over 10cm in width or girth and apply two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 50 | M&L PCC (1:3:6) type C-2 40mm graded stone aggregate as in fixing of Steel Post and mass concrete etc all as specified. |
| 51 | Dismantling of brick tiles or terracing tiles single layer bedded in cement mortar on roof complete all as specified and directed. |
| 52 | M&L 40mm thick brick tiles laid on cement mortar 1:6 and pointing in CM 1:3 15mm thick screed bed complete all as specified and directed. |
| 53 | Demolition of cement concrete in roof including plastering and leeping including cleaning surface of roof with wire brush / mechanical brush throughly to remove old dirt / loose particles to expose clean concrete slab clean with watering etc complete all as specified and directed. |
| 54 | M&L for PCC 1:2:4 type B-0 using 12.50mm graded stone agg with WPC as in padding to maintain proper slope as required al as specified (WPC shall be paid separatly.) |
| 55 | M&L for PCC 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) as in roof kerb / benching in radius 10 cm with waterproofing compound as per manufacturer's instructions complete all as specified and directed. |
| 56 | M&L for cutting out cracks to V section in existing roof or terracing, cleaning out, wetting, grouting with cement and sand slurry in 1:3 complete all as specified and directed. |
| 57 | M&L for water proofing treatment to flat roofs and edges (vertical or tapered) etc. in following sequence:- (i) Properly cleaning and drying the surface(ii) Applying a coat of bitumen primer @ 0.25 Kg/Sqm (iii) Applying a coat of hot air blown grade bitumen 85/25 @ 1.2 Kg/Sqm (iv) Laying of 3 mm thick ProShield APP (Atactic Polypropylene) modified bituminous waterproofing membrane with mineral-top surface with 100mm overlaps, sealed and bonded to the surface by 'torchon sealed' method as per manufacturer's instructions complete all as specified and directed. |
| 58 | Dismantling of stone slab and tiles of any description or thickness laid bedded and pointed in any mortar in floor,wall, aprons etc complete all as specified and directed. |
| 59 | M&L in Machine cut mirror Plolished kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing over 20mm thick screed bed in CM (1:6) complete |
| 60 | Dismantling of wall/false ceiling board, fiber insulation board any thickness including wooden cover fillets aluminium frame work as directed . |
| 61 | S&F anodised aluminium snap grid ( size 605mm x 605mm) frame work for false ceiling with hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long and fixing 4mm thick non asbestos fibre cement building boards fixed or laid/inserted to aluminium framed work complete all as specified and directed. |
| 62 | Dismantling existing transparent PVC sheets in roof complete all as specified |
| 63 | S&F 2.0mm thick fibre glass reinforced translucent corrugated sheeting with two corrugations side lap fixed in roof etc complete all as specified and directed. |
| 64 | Dismantling of asbestos cement (corrugated or semi corrugated sheet in roof covering) etc. complete all as specified and directed at site complete all as specified and directed. |
| 65 | M&L for 6mm thick AC corrugated or semi corrugated sheet in roof covering etc fixed with `L' type or `J' type or cranked hooks including washer etc complete all as specified and as directed. |
| 66 | M&L for 6 mm thick asbestos cement, two piece adjustable serrated ridge for corrugated and semi corrugated sheets fixed with ‘L’ or ‘J’ type or cranked hooks bolts complete all as specified and directed. |
| 67 | M&L PCC 1:3:6 type C2 40mm graded stone aggregate as in fixing of Steel Post and mass concrete etc complete all as specified and directed. |
| 68 | S&F Framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed at site. |
| 69 | Demolition of reinforced cement concrete in roofs, beams, staircase, lintels, chajja, RCC OHT etc complete all as speciifeid |
| 70 | M&L reinforced cement concrete (nominal mix) type B1 1:2:4 (20 mm graded aggregate) in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, copies, deck slabs, shelves and for fixing rungs etc including necessary form work complete all as specified and directed. |
| 71 | S&F for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete, all specified and directed. |
| 72 | M & L for Non-skid coloured ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.36 sqm, in floors/skirting etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed bed in CM (1:6) including dismantling floor, hearth or wall tiling including dismantling of tiles, complete all as specified and directed. |
| 73 | M&L for Glazed ceramic coloured tiles 350x 250x 7mm/ 450X 350X 7mm thick, laid on vertical surfaces such as skirting, dados and risers to steps etc laid over 10mm thick cement plaster in CM (1:4) set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles includingdismantling of tiles, complete all as specified and directed. |
| 74 | M&L for doublecharged Vitrified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles nog exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed in CM 1:6 including dismantling of tiles, complete all as specified and directed. |
| 75 | Demolition of cement concrete un- reinforced of any description and in any position not otherwise specifically provided for complete all as specified and directed. |
| 76 | M&L 75mm thick cement concrete 1:4:8 type D2 using 40mm graded stone aggregate as in sub base complete all as specified. |
| 77 | M&L Chequered cement concrete tiles with grey cement & pigment 20cm x 20cm x 25mm thick, set, jointed and pointed in neat cement slurry in floors including 20mm thick screed bed or beding layer of mortar in cement mortar 1:4 for laying floor finishes all as specified and directed. |
| 78 | M&L 100mm thick cement concrete 1:4:8 type D2 using 40mm graded stone aggregate as in sub base complete all as specified. |
| 79 | M&L for Machine pressed precast concrete interlocking paver block vibro compacted rubber moulded with grey cement and pigment any shape and size confirming to IS 15658-2006 of 80 mm thickness, M-40 Grade complete including 50 mm thick sand cushioning layer under the floors and hand level surface including watering and consolidation to receive floor tiles complete all as specified and directed. |
| 80 | M&L 100mm thick PCC 1:2:4 type B-1, using 20mm graded stone aggregate as in hard standing finished even and smooth without using extra cement including spike rolling to surface or making impression of expanded metal whilst the concrete is green complete all as specified and directed. |
| 81 | M&L 75mm thick cement concrete (1:3:6) type C-2, (1:3:6) using 40mm graded stone aggregate as in plinth protection and path laid in panels not more than 3.0 mtr in lenght laid to slope 1:30 including forming joints 10mm wide and duly filled with mastic bitumen (01 part bitumen mixed with 03 Parts of sand) surface,complete all as specified and directed.(Note:- The quoted tates are deemed to be inclusive of material against work and joints fillings.) |
| 82 | M&L for raking out cement mortar joints/pointing to brick work in walls or to bricks on edge in floors, surface channels, roofs etc complete all as specified and directed |
| 83 | M&L for flush pointing in brickwork laid flat on roof surface etc with using cement mortar 1:3 complete all as specified and directed |
| 84 | S&F 500 ltr capacity triple layer, rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position with 20mm bore high desity plastic ball brass valves, high pressure of PTMT with epoxy coated aluminium rod screwed for iron pipe and fixed including dismantling water tanks of capacity exceeding 250 litres but not exceeding 500 litres all as specified and directed. |
| 85 | Taking down of rain water pipes, of any dia and pattern complete all as specified and directed. |
| 86 | S&F 110mm dia PVC (SWR) soil, waste and vent pipes single socketed in any length with rubber ring joints, fixed to walls complete all as specified and directed. |
| 87 | S&F 75 mm dia PVC (SWR) soil, waste and vent pipes single socketed in any length with rubber ring joints, fixed to walls complete all as specified and directed. |
| 88 | S&F 110 mm dia PVC (SWR) bends any radius complete all as specified and directed. |
| 89 | S&F 75 mm dia PVC (SWR) bends any radius complete all as specified and directed. Total in Figures 23 0.0 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |