| 1 | Part-A - Civil Works)Providing and fixing at all height wall lining for acoustic treatment of 12.5mm thick tapered edge perforated gypsum board of size 590mmx590mm confirming to IS:2095 including providing and fixing of frame work made of special sections power pressed from M.S. sheet and galvernised in accordance with zink coating 600 as per IS:277 and consisting of angle cleats of size 25mm wide x 16mm thick with flanges of 22mm and 37mm at 1200mm c/c one flange fixed to the wall with dash fastner 12.5mm dia x 40mm long with 6mm dia bolts to the angle hangers of (25x25x5)mm of required length, and other end of angle hanger being fixed with nut and bolts to G.I. channels 45mm x 15mm x 0.9mm running at the rate of 1200mm c/c to which the ceiling section 0.5mm thick bottom edge of 80mm with tapered flanges of 26mm each having clips of 10.5mm at 450mm c/c shall be fitted in direction perpendicular to the G.I. channel with connecting clips made out of 2.64mm dia x 230m long G.I. wire at every junction including fixing the perforated gypsum board with ceiling section and perimeter channel l0.5mm thick 27mm high having flanges of 20mm and 30mm long, the perimeter of ceiling fixed to wall/ partition with the help of rawl plugs at 450mm c/c with 25mm long drive-all screws at the rate of 230mm in interval including fixing thermal insulation with resin bonded fibre glass wool confirming to IS 8183 (Twiga Insul 1000/50mm or equivalent) density 16 kg/m³ 50mm thick wrapped in 200G Virgin Polythene bags placed over existing wall and held in position by crisscrossing G.I. wire, jointing and fixing to a flush finished tapered and square edges of the gypsum board with recommended filler, paper tapes, finisher and 2 coats of primer suitable for gypsum board as per manufacture, specification and also including the cost of making openings for light fittings, sound system, grills, diffusers, cut outs made with frame of perimeter channels suitable fixed all complete including, cost, conveyance, royalties of all materials and cost of all labour T&P required for the work as per drawing and specification and direction of the Engineer-in-charge |
| 2 | ACCOUSTIC PANELLING:- Supply & installation of wall paneling of Anutone / Tranquil / Mechtrix Nishabdm slats surco high density fiberboard made out of pure pinewood particles , Fire Resistance - Pink in colour core with 5 test Fire Resistance BS 476 part 5 , BS 476 part 6 , BS 476 part 7 ISO 1182 ASTM E662 Smoke Density - Melamine laminated finish, perforated wooden grooved HDF slats L16-2 (2 mm grooves @ 8 mm centers),tongue-groove edge for a seamless look of linear dimension size 128 mm x 2440 mm x 16 mm thick having density 700 Kg /m3, weight -9 Kgs/m2 with back fleecs from soundtex Germany nonwoven acoustic to be pasted on slats surco is to be installed by using GI strut system. The technical parameters are as follows Core Variants - Fiberboard, Climate (OC RH) – 50, 70 Light reflectance – 75%,Green (RC %) – 25, Hygiene (VoC, Clean room) – Low, Class 1,Strength, Load capacity (Kg) - Anti sag, Ball-Impact. The concealed wall paneling system shall include GI Wall channel (WC25) having thickness 0.45mm, length 3600mm, unequal flanges of 15 & 20mm and web of 25mm should be fixed along the perimeter of the wall with nylon sleeves and suitable fasteners at every 300mm center. Then fixed Main channels (MC45) having thickness 0.9mm, length 3600mm, equal flanges of 15mm and web 45mm from the side wall & fixed at every 1200mm centers with GI cross channel(CC25) having thickness 0.45mm, length 3600mm, knurled web 35mm, depth of 25mm and equal flanges 9.5mm is fastened to the Main channel in the direction perpendicular to the Main Channel at every 600mm center. The framework will maintain 50 / 75 mm gap from the walls. Now clad the wooden slats surco on the CC 18 with the help of center & edge clips to get better locking of slats. The tongue & groove are to be properly aligned to get flush look . Synth poly fiber PF 5 x 50 wool of 500 gsm to be filled between the horizontal & vertical studs as in filler with the help of wire / stick & adhesive. Test certificate of the use products shall be submitted after procurement of materials The rate shall be including all cost of materials , labour, overheads T & P etc., complete as per the detail design and specification approved by Engineer -in-charge /Architect |
| 3 | Supplying, fitting and fixing up Roller Blind including all fitting, basic cost of materials, labour, T&P. etc. including labour cess but excluding GST complete as per direction of Engineer-in-charge |
| 4 | Providing fitting, fixing Door closure (Godrej Make) including basic cost, conveyance of all materials, cost of all labour, T&P required for the work etc. including labour cess but excluding GST complete as per direction of the Engineer-in-charge |
| 5 | Finishing wall surfaces of wall with acrylic wall putty (water based) of approved make and finished smooth and even surface to receive painting including basic cost, conveyance, of all materials, all labour, T&P. required for the work etc. including labour cess but excluding GST complete as per direction of the Engineer-in-charge |
| 6 | Priming one coats with any approved primer to surface of walls & ceiling including basic cost, conveyance of all materials, labour, T&P. required for the work etc. including labour cess but excluding GST complete as per direction of Engineer-in-charge |
| 7 | Finishing wall with plastic emulsion paint of approved shade two coats to surface of walls including basic cost of paint, conveyance of all materials, labour, T&P. required for the work etc. including labour cess but excluding GST complete as per direction of Engineer-in-chargeGround Floor |
| 8 | 1st Floor |
| 9 | Painting two coats with enamel paints of approved shade in all floors to wood and iron works including sand papering, polishing the surface, basic cost, conveyance, of all materials, all labour and T&P. required for the work including labour cess but excluding GST including the cost of paint and primer as per the direction of the Engineer-in-charge Please Enable Macros to View BoQ information |