| 1 | Part -A (Civil works)Earthwork in excavation in all types of soil for site leveling, foundation, pits, trenches and other civil works upto and including 1.5 metre lift and stacking the soil upto a lead of 100 metre and including dewatering, removing slush,shoring and strutting (as required), complete as per specification and as directed by the Engineer-In-Charge. |
| 2 | Filling at all depth with available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 15cm in depth: consolidating each deposited layer by ramming and watering complete (lead upto 100m) as directed by the Engineer-In-charge. |
| 3 | Supplying and filling sand in foundation and over areas including watering, ramming, consolidating and dressing, labours, tools, taxes etc. all complete as per the specification and direction of Engineer-In-charge. |
| 4 | Pre-Construction Anti-termite treatment to your site with lmidachloprid 30.5 SC or chloropyrifos 20% EC as per IS 6313 Part-III (2013) revision including all materials and Labour cost etc. |
| 5 | Providing and laying plain cement concrete 1:3:6 (1 cement : 3 sand : 6 stone agregate 40mm nominal size) as levelling course in foundation and plinth etc. including tempering, curring, shuttering etc. complete all depth and height. |
| 6 | Fly ash brick masonry in cement mortar (1:6) in Foundation and Plinth using (25x12 x8cm) size bricks after immersing the bricks for six hours in water before its use including, splays cutting, circular moulding and carbelling, champering and similar such type of works watering, curing etc. all complete including basic cost, conveyance, royalties of all materials and cost of all labour, and T&P required for the work etc. including labour cess but excluding GST complete (Crushing strength of bricks should not be less than 75kg to 99 kg/cm2 with dimensional tolerance ±2%) |
| 7 | Fly ash brick masonry in cement mortar (1:4) in Superstructure using (25x12x8cm) size bricks after immersing the bricks for six hours in water before its use including, splays cutting, circular moulding and carbelling, champering and similar such type of works watering, curing etc. all complete including basic cost, conveyance, royalties of all materials and cost of all labour, and T&P required for the work etc. including labour cess but excluding GST complete (Crushing strength of bricks should not be less than 75kg to 99 kg/cm2 with dimensional tolerance ±2%) as per specification & direction of the Engineer -in-ChargeGround Floor |
| 8 | Terrace Floor |
| 9 | Providing, lifting, hoisting and laying Reinforced cement concrete of M-20 grade as per approved designs and drawings having a minimum compressive strength (in work test) 25 Kg. / Square cm. in 15 cm. cubes at 28 days after mixing and test conducted in accordance with I.S. 516 using 12 mm. to 20 mm. size black hard crushed broken granite stone chips and screened and washed sharp sand for mortar of approved quality from approved quarry, washed and cleaned ( 20mm. size chips not to exceeds 25 % ) to be mixed in concrete mixture with Portland slag cement (PSC) including hoisting, lowering, laying and compaction concrete by using vibrators, watering and curing for 28 days, centering and shuttering then after dismantling and removing debris from the work site and finishing the exposed surface smooth providing grooves or beads wherever necessary including cost, conveyance, loading, unloading, royalties and taxes of all materials and cost of all labours, sundries, T & P required of the work etc. complete in all respect as directed by the Engineer-in-Charge. But excluding cost and conveyance of M.S. rods or Tor steel and binding wires and labour charges for straightening, cutting, bending etc. of M.S. rods or tor steel tying the grills and placing in proper position.Footing |
| 10 | Column Ground Floor |
| 11 | Terrace Floor |
| 12 | Plinth beam |
| 13 | Lintel Ground Floor |
| 14 | Chajja Ground Floor |
| 15 | Terrace Floor |
| 16 | Roof Beam Ground Floor |
| 17 | Terrace Floor |
| 18 | Roof Slab. Ground Floor |
| 19 | Terrace Floor |
| 20 | Staircase |
| 21 | Supplying, straightening, cutting, bending, placing in position and binding reinforcement steel work in RCC/reinforced brick works as per drawing and specification including preparation of respective bar bending schedule and binding (Binding wire to be used as per the IS code) etc. all complete as per direction of Engineer-in-charge Cold Twisted bars, Thermo-Mechanically-treated bars. ground floor |
| 22 | Terrace Floor |
| 23 | 12mm cement plaster on external RCC/brick surfaces in cement plaster 1:6 (1 cement : 6 coarse sand) including necessary scaffolding, curing etc. all complete at all floors and all heights. (External Surface) ground floor |
| 24 | Terrace Floor |
| 25 | 16mm cement plaster on internal smooth side of RCC/brick surfaces with cement mortar of mix 1:6 (1 cement : 6 fine sand) including necessary scaffolding, curing etc. all complete at all floors and all heights. (Internal Surface) ground floor |
| 26 | Terrace Floor |
| 27 | Providing 6mm thick cement plaster in RCC surfaces including deep chiping and slurry treatement at all floors at all height with cement mortar of mix (1:4) with cost, conveyance, loading and unloading, royalties and taxes of all materials and cost of all labours and scaffolding required for the work etc. complete in all respect as per specification and direction of Engineer-in-charge. ground floor |
| 28 | Terrace Floor |
| 29 | 2.5cm (1\\") av. thick A.S. flooring with cement concrete of proportion (1:2:4) including punning with black hard crusher broken granite chips laid in two layers the bottom layer being ¾\\" thick ¼\\" to ¾\\" size black hard broken granite chips of approved quality & from approved quarry & Top layer of ¼\\" thick with 1/8\\" to ¼\\" size black hard crusher broken granite chips laid down over 4\\" dry epidorite metal in ground floor including rounding of corners watering, curing with basic cost, conveyance, royalties of all materials, & cost of all labour, T&P. required for the work etc. including labour cess but excluding GST complete in all floors as per specification & direction of the Engineer -in-Charge |
| 30 | Aluminum DoorsProviding and fixing System Aluminum works for Opening doors and windows of TOSTEM make with 50mm visible aluminium section width in the centre mullion. The extruded aluminium sections should be made from Grade 6063-T5 & Anodized with Texguard coating, silicon coated to suit marine atmosphere. All profiles should be None insulated Profiles. Corner connection will be Butt joint with Screw using Nano gaskets for sealing. All other major Accessories should also be made by the same manufacture. All Slider doors & windows will be centre locking. Integrated Anti-lift in slider panel, EPDM gaskets should be used in slider windows & doors in all meeting points instead of Brush Pile. The outer frame Depth will be 72mm. All materials which are used should be corrosion-resistant so that they are good functioning in different environments and that there are no negative influences either on the aluminium or on the surface treatment.The system should allow the application of glazing or panels with thickness up to 8mm. The external perimeter of aluminum sections should be Anodized with Texguard coating, the system should qualify Airtightness ASTM E283: 10.7m3/h.m2 at 75Pa of pressure, Water tightness ASTM E300: 240 Pa, Wind load resistance ASTM E330: 2000 Pa. System should have a 10-year warranty on properties, functionality and design, within restrictions defined by technical specifications of anodizing & 1-year warranty on wearing parts only applies to normal and realistically foreseeable use. All Slider doors & windows will be center locking. Glass to be used is 6 MM TOUGHENED . |
| 31 | Supplying , fitting and fixing of two track UPVC sliding window of approved make with 6mm thick glass of approved quality complete with frame, shutters and all fitting and fixtures.ground floor |
| 32 | Providing and fixing M.S grill of required patterns for windows/verandahs etc. with M.S flats, square or round bars etc. including applying a coat of approved steel primer and two or more coats of synthetic enamel paint of approved make & shade, all complete as per drawing & specification. (All steel sections contractor's own supply) at all floors and all heights. ground floor |
| 33 | Providing & Applying priming one coat with Cement primer of approved brand and manufacture on plaster surface as per the instruction of Engineer-In-Charge at all elevations including all material & labour complete at all floors and all heights. Ground floor |
| 34 | Terrace Floor |
| 35 | Providing and applying to outside walls with two or more coats of Anti-Fungal Weather coat water proofing paint including scaffolding and cleaning the surface before application of approved colour and manufacture as per specification, instruction of Engineer-In-charge at all elevations including all material labour complete at all floors and all heights. (External Surface)Ground floor |
| 36 | Terrace Floor |
| 37 | Providing and applying acrylic wall putty of average thickness 1 mm of approved brand and manufacturer, over the plastered wall surfaces to prepare the surface even and smooth as per the instruction of Engineer-In-Charge at all elevations including all material & labour complete at all floors and all heights. |
| 38 | Terrace Floor |
| 39 | Preparing surface and painting at all height with two or more coats of interior Plastic Emulsion \\", of approved shade as per the instructions of the manufacturers; giving uniform shade etc in all heights of walls etc. & providing scaffolding, cleaning, curing and supply of all materials and labour complete as per drawing, design and direction of Architect/Engineer-In-Charge at all floors and all heights. (Internal Surface)Ground floor |
| 40 | Terrace Floor |
| 41 | Providing & Painting with synthetic enamel paint of approved brand and manufacture to give an even shade as per the instruction of Engineer-In-Charge at all floors and all heights including all material & labour complete at all floors and all heights.Ground floor |
| 42 | Terrace Floor |
| 43 | Supplying, fitting and fixing of Stainless steel of 304 grade in hand ralling using 50mm dia of 2mm thick circular pipe with Balustrade of size 32mm X 32mm X 2mm @ 0.90mtr. C/C and stainless square pipe bracing of size 32mm X 32mm X 2mm in 3 rows in stair case as per approved design and specification, buffing, polishing etc with cost, conveyance, taxes, all materials, labour, T&P etc. required for the complete in all respect. at all floors and all heights. |
| 44 | Providing and laying grading conc. 25 mm (avg. thickness) cement concrete of required slope of mix 1:2:2 (1cement:2sand:2 graded stone aggregate of 10 mm nominal size) mixed with approved water proof compound as per manufacturer's specification on top of slab including cement slurry, all complete, including the cost of water proofing admixture, which should be approved by the Engineer-In-Charge prior to material procurement by the contractor. |
| 45 | Supplying, fitting & fixing of Vitrified Wall tiles of premium grade having thickness 8mm to 10mm confirming to IS 13755 of size 60cm x 60cm coloured/printed series in dadoes, skirting and risers of steps of laid on 12 mm thick cement mortar (1:3) (1 cement : 3 course sand) jointed with slurry mixed with pigment to match the shades of the tiles etc. complete including cost of all materials, labour T&P etc. required for the work all complete as per direction of the Engineer-in-charge. |
| 46 | Providing and fixing M.S Door of required patterns for Gate/Door etc. with M.S Sheet, square or round bars etc. including applying a coat of approved steel primer and two or more coats of synthetic enamel paint of approved make & shade, all complete as per drawing & specification. (All steel sections contractor's own supply) at all floors and all heights. |
| 47 | Dismantling and removing R.C.C. columns beams slab staircase landing lintels including stacking the useful materials for reuse and removing the debris within 50m lead |
| 48 | Dismantling brick or stone masonry in lime or cement mortar above 3m height including stacking the useful materials for reuse and removing the debris within 50m lead. |
| 49 | Dismantling and removing doors, windows and ventilators including removal of frame, hinges, fastening and stacking the same for reuse and removing the debris within 50m lead |
| 50 | Part-B (E.I Works)WiringRecessed wirring to light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor of ISI marked Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI with 20 mm dia HMS FRLS PVC conduit ISI marked Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal 6A modular type ( flame retradant type) switch ISI marked Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) and ceiling rose ISI marked of modular type G.I box with metallic cover plate (both side) ( flame retradant type) Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) of suitable size, modular box with 1.5 sq. Mm FRLS PVC insulated single core multistandard copper conductor as earth wire including all accessories and connection as per direction of Engineer -in -Charge. . All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials.Group A |
| 51 | Group B |
| 52 | Group C |
| 53 | Supply and fixing of ISI marked modular type 2nos 6Amp socket with switch on suitable size of metal box and modular cover in front on surface or recess including all conection as per direction of E.I.C. All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials. (Make :Legrand(Myrius)/Schnider(Zencelo)//PANASONIC(VISION) |
| 54 | Supply and fixing of modular metal box on surface or recess with suitable size of modular cover in front including providing an fixing of ISI marked 16Amp modular plug with switch with all conection. on surface or recess including all conection as per direction of E.I.C. All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials. (Make :Legrand(Myrius)/Schnider(Zencelo)//PANASONIC(VISION) |
| 55 | Supply& fixing of Modular type 6 Amp one way switch and 6 A socket outlet with metal box and modular cover Separate Board on surface or recess including all conection as per special conditions of contract making good the damages caused complete as per the direction of Engineer-in-charge. All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials. (Make :Legrand(Myrius)/Schnider(Zencelo)//PANASONIC(VISION)) |
| 56 | Supply, delivery, installation, testing and commssioning of modular type TV Antenna Outlet Boards containing a ISI marked Modular TV Antenna/Telephone Socket fixed on Modular Concealed Box including connections and making good the damages caused complete as required and as per Dierction of Engineer-In-Charge.. |
| 57 | Supplying and installation of AC Point having 16-20A DP MCB, C series with enclosure, Schneider/Siemens/Legrand/ABB of suitable size as required as per direction of Engg.-in-Charge .All the Components should be warrantied for a replacement period of 1 year against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 58 | Submains:Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 1.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor. In 20 mm dia non metallic heavy duty conduit (LDB to LSB/LIGHT CKT)(2X1.5+1X1.5) |
| 59 | 2 nos single core 2.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit.(BDB to LSB/LIGHT CKT/5A PLUG/UPS POINT ) (2X2.5+1X1.5) |
| 60 | 2 nos single core 4 sq. mm copper wire for phase and neutral and 01 no of single core 2.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit .(PDB to PSB/ POWER POINT/AC POINT) (2X4+1X2.5) |
| 61 | 2 nos single core 6 sq. mm copper wire for phase and neutral and 01 no of single core 2.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit .(PDB to PSB/ POWER POINT/AC POINT) (2X6+1X2.5) |
| 62 | Supplying and fixing of following sizes of medium class PVC FRLS conduit ISI marked along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required as per direction of Engg.-in-Charge .Make-AKG/ BEC/ Precision/ Norpak 20 MM |
| 63 | 25 MM |
| 64 | Supplying and fixing of following mentioned way, single pole and neutral, sheet steel,double door MCB distribution board, 415 volts/240 volts shall be as per IEC 61439-3,integrated door earthing system offering additional safety to the user,High quality polyurethane Gasket,the box and cover shall be fabricated to withstand IK09,the DB should be properly pre-treated with 7 tank process and duly powder coated, phosphatized with powder coated finish, on surface/recess, complete with terminal blocks,with suitable size FR PVC insulated copper conducter up to terminal blocks, tinned copper busbar, neutral busbar, earth bar, din bar. Make-LEGRAND-Ekinox3 DB/ Siemens-Betaguard/ Schneider- Acti 9 as per direction of Engg.-in-Charge. The Distribution boards should be Replacement Warranty will be 3 years.16 Way SPN MCB DD DB Horizontal Type as per IEC 61439-3 suitable for Flush mounting and Surface mounting with 63A Copper Bus Bar for each phase, with neutral Bus bar, Earth Bar & Cable ties for cable management, prefitted masking sheet, IP43-IK09 with metal door Warranty on DB is 3 years |
| 65 | Supplying and fixing 63 Amps rating,C series,10KA breaking capacity, DP, 240 volts, MCB 10kA . Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. . The MCB should be Replacement Warranty will be 3 years. |
| 66 | Supplying and fixing 6 amps to 32 amps rating, 240 volts, C series,10KA breaking capacity, single poles MCB of Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9. the existing MCB DB complete with connections as per direction of Engg.-in-Charge. .Warranty on MCB is 3 years. |
| 67 | Supplying and fixing of Energy efficient surface /recess mounted square /round shape 18 W LED luminaire of dimension of consists of white powder coated , die-cast Alluminium housing with high quality frosted diffuser for glare-free uniform lighting distribution with wattage not more than 18 watt and lumen output of 1800 lumens, , CRI not less than 80,CCT of 6000 degree K,THD less than 10%, with electronic driver, internal surge protection of 3 KV , L70 B50: 50000 hrs and all other accessories suitable for operation on 220 V to 240 V supply as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj).The luminaire should be Replacement Warranty will be 2 years |
| 68 | Supply of 20 watt surface mounted indoor type battern LED Luminaire with LED GLARE FREE opal diffuser , IP20 Efficency 120-130lm/w luminaire of dimension of consists of white powder coated , die-cast Alluminium housing with high quality frosted diffuser for glare-free uniform lighting distribution with wattage not more than 20 watt and lumen output of 1800 lumens, , CRI not less than 80,CCT of 6000 degree K,THD less than 10%, with electronic driver, internal surge protection of 3 KV , L70 B50: 50000 hrs and all other accessories suitable for operation on 220 V to 240 V supply as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj).The luminaire should be Replacement Warranty will be 2 years |
| 69 | Supplying, installation, of exhaust fan of heavy duty 300 mm sweep 1400 rpm 1700 cmh air delivery with louvers of exhaust fan in the existing wall, including fixing & conntection complete etc.as required and as per the direction of E.I.C..(Make-USHA (Model.Turbo HDEF 1400 RPM ISI)/Eq. model of /Havells/ ALmonrad/ Crompton |
| 70 | Supplying, installation, testing and commssioning of 1200 mm sweep BLDC ceiling fan with aluminium blades having wattage not more than 28W and Air delivery ≥ 215(m3/min) Make-USHA(Teohnix)/Crompton(Energion Groove)/Havells(Efficiencia Neo ) including wiring the down rod of standard length (upto 30 cm) with 1.5 sq mm PVC insulated, copper conductor, single core cable etc. as required as per direction of Engg.-in-Charge,Replacement Warranty will be 4 years.. .(With fan Regulator) |
| 71 | Supply delivery, installation and testing of 120 watt PREMISES Light Surface mounted OUTDOOR type LED Luminaire with LED GLARE FREE opal diffuser , IP66 Efficency 120-130lm/w Lamp complete assembly With supply of required T&P and making connection from the suitable point outlet as per the Direction of Engineer-In-Charge. .The luminaire should be Replacement Warranty will be 2 years MAKE:PANASONIC/PHILIPS/HALONIX/CROMPTON/WIPRO/HAVELLS/LT |
| 72 | Supply ,installation ,testing & commissioning of Inverter 12V 220Ah battery generally , runtime drops to about 5–7 hours.Voltage Compatibility: Standard units are designed for 12V batteries, though switchable models (6V/12V or 12V/24V) are available for different system configurations.Battery Chemistry Support: Most are compatible with Tall Tubular Lead-Acid battery for long-lasting, heavy-duty performance, or a Lithium-ion battery Safety Protections: Built-in Reverse Polarity Protection prevents damage if cables are hooked up backwards, and Spark-Proof connections ensure safety during lead connection. (Make:Luminious/exide/ Livguard/) , as per direction of Engg.-in-Charge. Warranty period of all accessories & component & system must be 2 years & complete test certificate must be submitted along with inverter including component list & SLD. |
| 73 | Supplying of one number PVC insulated armoured and PVC sheathed XLPE property AL. conductor power cable of 1.1 KV grade Make- Finolex/Polycab/HAVELLS/RR KABLE/KEI/Gloster of following size cables as per direction of Engg.-in-Charge.Supply and laying of3 core 2.5 sqmm Flexiable copper cable (for Premises light) |
| 74 | Supplying,installation,testing & commissioning Of Earthing with copper earth plate 600 mm x 600mm x 3.15 mm thick ISI marked including accessories and providing masonary with cover plate having loccking arrangement and watering pipe etc as required as per direction of Engg.-in-Charge. The entire earthing system should be Replacement Warranty will be 2 years |
| 75 | Extra for using salt and charcoal for G.I or copper plate earth as required |
| 76 | Providing and fixing 25 mm X 5 mm GI strip on surface or in recess for connections etc. as required. |
| 77 | Providing and fixing ABC type fire extinguishers consisting of welded M.S cylindrical body, squeeze lever dischange valve fitted with pressure indicating gauge internal discharge tube, 30cms long high pressure discharge hose, discharge nozzle, suspension bracket, conforming to IS finished externally with red enamel paint and fixed to wall with brackets complete with internal charge.Make- Safex/Supremex/ Ceasefire/Flameklog.6 kg capacity Please Enable Macros to View BoQ information |