| 1 | Supply & Installation of 50 gm aerosol based Manual Fire Extinguisher (Duration:10-20 sec) , EN 15276-1:2019 and EN 15276-2:2019 ,ISO 15779:2011 approved ,capable for extinguishing Class A, B, C & E fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg Celcius including all accessories as per the direction ofEngineer-in-Charge. Replacement warranty on the product shall be 3 years and shell-life of 5 years. Make-Pyrogen/Genefire/Stat-x |
| 2 | Supply & Installation of 500 gm Portable Aerosol based Automatic triggering through linear heat detection cable/electrical initiation Fire Extinguisher (Coverage: 5 m3) , EN 15276-1:2019 and EN 15276-2:2019 ,ISO 15779:2011 approved ,capable for extinguishing Class A, B, C & E fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg Celcius including all accessories as per the direction ofEngineer-in-Charge. The triggering device should be compatible with linear heat detector to detect heat and should use industrial lithium ion battery with 10 yrs service life to supply electrical power in order to activate the aerosol module. Replacement warranty on the product shall be 3 years and shell-life of 10 years. Make-Pyrogen/Genefire/Stat-x/Ceasefire |
| 3 | Supply & Installation of 3.3 Kg Manual aerosol based Fire Extinguisher covering 150m3 for big fire (Throwable unit) , EN 15276-1:2019 and EN 15276-2:2019 ,ISO 15779:2011 approved ,capable for extinguishing Class A, B, C & E fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg Celcius including all accessories as per the direction ofEngineer-in-Charge. Replacement warranty on the product shall be 3 years and shell-life of 10 years. Make-Pyrogen/Genefire/Stat-x |
| 4 | Supply & Installation of 8 gm Portable Aerosol based Automatic Fire Extinguisher (Coverage: 0.008 m3), EN 15276-1:2019 and EN 15276-2:2019 ,ISO 15779:2011 approved ,capable for extinguishing Class A, B, C & E fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg Celcius including all accessories as per the direction of Engineer-in-Charge. Replacement warranty on the product shall be 3 years and shell-life of 10 years. Make-Pyrogen/Genefire/Stat-x |
| 5 | FIRE EXTINGUISHERSupplying, installing and commissioning of ISI ABC Powder 4 Kg Fire Extinguisher containing Mono Ammonium Phosphate Powder 50, Stored Pressure Type,Pressure Gauge, fittted with discharge hose, wall mounting bracket etc., Discharge Time less than 15 Secs, Controllable discharge mechanism, Range minimum 4 Meters, applicable on Class A,B,C and electrically started Fire, A Rating- 8A, B Rating 34B, Can Construction : Deep drawn & Co2 Mig welded, Valve Construction : Forging & Machining, Internal Coating of Can : Epoxy Powder coating, External Coating of Can : Epoxy Polyster Powder coating, Sheet metal thickness : 1.60MM, ISI approved as per IS:15683:2006(Make: superimax/Cese fire/Minimax) |
| 6 | Supplying, installing and commissioning of CO2 Type 4.5 Kg Fire Extinguisher containing Mono Ammonium Phosphate Powder 50, Stored Pressure Type, Pressure Gauge, fittted with discharge hose, wall mounting bracket etc., Discharge Time less than 15 Secs, Controllable discharge mechanism, Range minimum 4 Meters, applicable on Class A,B,C and electrically started Fire, A Rating- 8A, B Rating 34B, Can Construction : Deep drawn & Co2 Mig welded, Valve Construction : Forging & Machining, Internal Coating of Can : Epoxy Powder coating, External Coating of Can : Epoxy Polyster Powder coating, Sheet metal thickness : 1.60MM, ISI approved as per IS:15683:2006(Make: superimax/Cese fire/Minimax) |
| 7 | Supply and installation of linear heat detection cable compatible with aerosol based fire extinguisher as per the direction of Engineer-in-charge. Make-Pyrogen/Genefire/Stat-x |
| 8 | Fire buckets (3 nos) (FILLED WITH SAND) round bottom type enamel painted, white inside & Red out side and Letter \\"FIRE\\" in black out side and handle with mounting bracket. |
| 9 | AUTOMATIC FIRE DETECTION SYSTEM Supplying, installation, testing and commissioning of Addressable Multi Detector(Smoke cum Heat) complete with base and isolator as per direction of Engineer-in-charge. |
| 10 | CONTROL PANEL Providing S.I.T.C of Microprocessor based Addressable Fire Alarm Control Panel (2 Loop) suitable for serving the followingg detectors & Devices in maximum with LCD display, complete with) 2 Nos 12 Volt 40 Ah SMF battery, Battery backup and also provision for 2 Nos potential free Normally open contact per loop to be used for interlocking of AHUs in the event of fire as per direction of Engineer-incharge. |
| 11 | MCP Supplying, installing ,testing and commissioning of break glass type Manual call point . The Manual call point with monitor module shall be single stage type with all accessories and suitable sinages complete., the Manual call point shall be as per technical specification. and shall be of EN and LPCP listed. |
| 12 | Electronic Hooters Supplying, installing ,testing and commissioning of Hooter Cum Strobe at 85 dBA @ 3m for Audible annunciation and 75cd flashing at 1 Hz for visual indication. With Control Module. The Hooter cum Strobe with Control Module shall be flush or surface mountable type with all accessories etc., complete and as per technical specification. The devices shall be of EN and LPCP listed (Make: Bosch or Equivalents) |
| 13 | Wiring Supplying and drawing of 2X1.5 sq.mm PVC insulated PVC Sheathed FRLS cable in the existing surface/ recessed conduit with all accessories as per direction of Engineer-in-charge. |
| 14 | Supplying and fixing of following sizes of heavy gauge PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required 25mm dia |
| 15 | FF EXIT SIGNAGESIGNAGES: SITC flexyl of Photoluminescent based Glow-in-the-dark sheeting with luminious properties enclosed in a weather-proof UV stabilized film with UV screen printing by imported inks pasted over 3 mm Thick Cast Acrylic Sheet with the Protection of 3 mm Thick Cast Acrylic from Front side with stud type mirror screw with lifespan of 5 years, visible upto 4-6 hrs in total darkness for floor indication, fire exit, hydrant, hose reel, fire extinguisher, MCP, fire alarm panel, in case of fire, lift, alarm valve signages Please Enable Macros to View BoQ information |