Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Part -A (Civil works)Removing old lime or cement plaster from walls including raking out joints 12mm deep and removing the debris within 50m lead. |
| 2 | Dismantling and removing doors, windows and ventilators including removal of frame, hinges, fastening and stacking the same for reuse and removing the debris within 50m lead |
| 3 | Dismantling and removing old tiled flooring including removing the base coarse and stacking the useful materials for reuse and removing the debris within 50m lead |
| 4 | Providing Fly ash bricks masonry work using (250mmx120mmx80mm size) having crushing strength not less than 75Kg/Sqcm in cement mortar (1:6). Immersing the bricks in water before use in all necessary projection splays cutting, circular moulding, corbelling etc. Including cost of conveyance ,taxes & royalties, loading and unloading of all materials & cost of all labour, scaffolding ,watering & curing ,sundries, T & P etc. complete as per the direction of Engineer-in-charge . |
| 5 | 16mm cement plaster on internal smooth side of RCC/brick surfaces with cement mortar of mix 1:6 (1 cement : 6 fine sand) including necessary scaffolding, curing etc. all complete at all floors and all heights. (Internal Surface)GROUND FLOOR |
| 6 | FIRST FLOOR |
| 7 | Providing 6mm thick cement plaster in RCC surfaces including deep chiping and slurry treatement at all floors at all height with cement mortar of mix (1:4) with cost, conveyance, loading and unloading, royalties and taxes of all materials and cost of all labours and scaffolding required for the work etc. complete in all respect as per specification and direction of Engineer-in-charge.GROUND FLOOR |
| 8 | FIRST FLOOR |
| 9 | Providing and laying Vitrified floor tiles 600x600 mm (thickness to be specified by the manufacturer) 1st quality of ,approved make, colours & shades laid on 20 mm thick cement mortar 1:4 (1cement: 4coarse sand ) including pointing the joints with white cement and matching pigments, etc. complete as per direction of Engineer-In-Charge at all floors and all heights.Ground Floor |
| 10 | FIRST FLOOR |
| 11 | Supplying, fitting & fixing of Vitrified Skirting tiles of premium grade having thickness 8mm to 10mm confirming to IS 13755 of size 60cm x 60cm coloured/printed series in dadoes, skirting and risers of steps of laid on 12 mm thick cement mortar (1:3) (1 cement : 3 course sand) jointed with slurry mixed with pigment to match the shades of the tiles etc. complete including cost of all materials, labour T&P etc. required for the work all complete as per direction of the Engineer-in-charge.Ground Floor |
| 12 | 1st Floor |
| 13 | Providing, fitting and fixing Vitrified industrial floor tile of size 300x300 mm of approved make conforming to IS: 13755 laid on 20 mm thick cement mortar 1:4 (1 cement: 4 course sand) and filling joints with white cement of approved quality including cost of all materials, labour T&P etc required for the work all complete as per direction of Engineer-In-Charge (for New work only)GROUND FLOOR |
| 14 | Supplying, fitting & fixing of 30cm x 20cm/20cm x 20cm special plain/printed series Ceramic wall tiles of premium grade having thickness 6.5mm to 6.7mm confirming to IS 13753 in dadoes, skirting and risers of steps laid on 12 mm thick cement mortar (1:3) (1 cement : 3 course sand) jointed with slurry mixed with pigment to match the shades of the tiles etc. complete including cost of all materials, labour T&P etc. required for the work all complete as per direction of the Engineer-in-charge |
| 15 | Providing and fixing ISI marked 30 mm thick flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak three ply veneering with vertical grains or cross bands and face veneers on both faces of shutters of approved design including cost of all door fittings and fixtures etc. complete |
| 16 | Supplying , fitting and fixing of two track UPVC sliding window of approved make with 6mm thick glass of approved quality complete with frame, shutters and all fitting and fixtures. |
| 17 | Providing and fixing M.S grill of required patterns for windows/verandahs etc. with M.S flats, square or round bars etc. including applying a coat of approved steel primer and two or more coats of synthetic enamel paint of approved make & shade, all complete as per drawing & specification. (All steel sections contractor's own supply) at all floors and all heights. |
| 18 | Providing & Applying priming one coat with Cement primer of approved brand and manufacture on plaster surface as per the instruction of Engineer-In-Charge at all elevations including all material & labour complete at all floors and all heights. Ground Floor |
| 19 | FIRST FLOOR |
| 20 | Providing and applying Acrylic Wall based putty of average thickness 1 mm of approved brand and manufacturer, over the plastered wall surfaces to prepare the surface even and smooth as per the instruction of Engineer-In-Charge at all elevations including all material & labour complete at all floors and all heightsGround Floor |
| 21 | FIRST FLOOR |
| 22 | Preparing surface and painting at all height with two or more coats of interior Plastic Emulsion \\", of approved shade as per the instructions of the manufacturers; giving uniform shade etc in all heights of walls etc. including interior wall primer & providing scaffolding, cleaning, curing and supply of all materials and labour complete as per drawing, design and direction of Architect/Engineer-In-Charge at all floors and all heights. (Internal Surface) Ground Floor |
| 23 | FIRST FLOOR |
| 24 | Providing & Painting with synthetic enamel paint of approved brand and manufacture to give an even shade as per the instruction of Engineer-In-Charge at all floors and all heights including all material & labour complete at all floors and all heights.Ground Floor |
| 25 | FIRST FLOOR |
| 26 | Supplying and Fixing of MAKE IN INDIA broadloom carpet of WELSPUN MAKE ,100% Nylon Cut Pile , Digitally Printed , Pile Height 7 mm (± 1 mm),Total Height 11 mm (± 1 mm),Stitch / 10 cm 37-39 (± 2% ), Pile Weight Net less Than 800 GSM (± 5% ), Total Weight 1791 GSM (± 5% ), Secondry Backing PP Mesh, Gauge 1/8 Cut Pile, Latex Natural Rubber, Color fastness to LightTest Method: AATCC 16 (20 AFU) ≥ 4.0 at 80 Hours , Static ElectricityTest Method: AATCC 134 Less than 3.5 KV, Hexapod test Method: ASTM D 5252 ≥ 4, Flammability (Radiant Panel),Anti Bacterial & Anti MicrobialTest Method: ASTM E 648 ≥ 0.45 (Class I) , complete as per drawing , specifications of the architect. The carpet and Underlay (min 6 -8 mm) will be installed with standard SR 998/SR505/MAPAI Adhesives.The flooring to be installed as per the manufacture's specification and to be installed by its authorized agency or as Approved , with minimum 5 Years warrenty from Principal for any manufacturing defects including cost of all materials, labour T&P etc required for the work all complete as per direction of Engineer-In-Charge |
| 27 | Providing, fitting,Gypsum Board False ceiling of approved design and drawing in all floors with G.I Section on 4 walls to be fixed by means of steel screw and PVC plug and the G.l. grid 2’-0”x2’-0” to be suspended from ceiling by using 12.5mm thick Fire Line Gypsum Board including cost of all materials, all labour, all T&P etc. required for the work complete in all respect as per the direction of the Engineer-in-charge.Ground Floor |
| 28 | FIRST FLOOR |
| 29 | Painting the Gypsum Board ceiling area with one coat of primer & two coat of flame spread resistence paint as per the detail design and specification including all cost of materials , labour, overheads T & P, taxes, etc., complete.Ground Floor |
| 30 | First floor |
| 31 | ACCOUSTIC PANELLING:- Supply & installation of wall paneling of Anutone / Tranquil / Mechtrix Nishabdm slats surco high density fiberboard made out of pure pinewood particles , Fire Resistance - Pink in colour core with 5 test Fire Resistance BS 476 part 5 , BS 476 part 6 , BS 476 part 7 ISO 1182 ASTM E662 Smoke Density - Melamine laminated finish, perforated wooden grooved HDF slats L16-2 (2 mm grooves @ 8 mm centers),tongue-groove edge for a seamless look of linear dimension size 128 mm x 2440 mm x 16 mm thick having density 700 Kg /m3, weight -9 Kgs/m2 with back fleecs from soundtex Germany nonwoven acoustic to be pasted on slats surco is to be installed by using GI strut system. The technical parameters are as follows Core Variants - Fiberboard, Climate (OC RH) – 50, 70 Light reflectance – 75%,Green (RC %) – 25, Hygiene (VoC, Clean room) – Low, Class 1,Strength, Load capacity (Kg) - Anti sag, Ball-Impact. The concealed wall paneling system shall include GI Wall channel (WC25) having thickness 0.45mm, length 3600mm, unequal flanges of 15 & 20mm and web of 25mm should be fixed along the perimeter of the wall with nylon sleeves and suitable fasteners at every 300mm center. Then fixed Main channels (MC45) having thickness 0.9mm, length 3600mm, equal flanges of 15mm and web 45mm from the side wall & fixed at every 1200mm centers with GI cross channel(CC25) having thickness 0.45mm, length 3600mm, knurled web 35mm, depth of 25mm and equal flanges 9.5mm is fastened to the Main channel in the direction perpendicular to the Main Channel at every 600mm center. The framework will maintain 50 / 75 mm gap from the walls. Now clad the wooden slats surco on the CC 18 with the help of center & edge clips to get better locking of slats. The tongue & groove are to be properly aligned to get flush look . Synth poly fiber PF 5 x 50 wool of 500 gsm to be filled between the horizontal & vertical studs as in filler with the help of wire / stick & adhesive. Test certificate of the use products shall be submitted after procurement of materials The rate shall be including all cost of materials , labour, overheads T & P etc., complete as per the detail design and specification approved by Engineer -in-charge /Architect |
| 32 | Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge excluding gst . |
| 33 | Suplly and Fitting of Wall Cladding of PVC material with all Materials Inculded required for installation directly on the wall as per the direction of the Engineer-in-chargeGround Floor |
| 34 | FIRST FLOOR |
| 35 | LOW HEIGHT STORAGE :-Providing & fixing of 750mm low height storage made out of 19 mm thick bwp ply, 6 mm thick bwp ply at out side & laminated with 1mm thick sued / texture laminate on out side & 0.8 mm thick laminate at in side , the exposed wooden surface edge binding to match the laminate with central locking, shutters with autoclosing hinges and handles. Including all cost of labour , taxes T & P etc as per the detail design & specificatio approved by EIC . ( Basic cost of texture laminate is Rs 55.48/- sft ) |
| 36 | Signages: Providing and Fixing of WPC boards of sizes as mentioned below along with 3D letter inlays on the same with the required letters to be approved by the Architect/ EIC. Samples have to be approved by the concerned before execution. The rate is inclusive of the WPC board with fixing of the same along with Rates, Taxes, T&P all inclusive. |
| 37 | PRODUCT : Revolving chairs |
| 38 | Conference Table Godrej Stance Height Adjustable Table - 1350 X 600 (Douglus Pine Top with Black Legs) |
| 39 | Providing Sika water proffing treatment with 3mm thick glass fibre reinforced App membrane (sika WP shield 102F) over one coat of sika Wp shield App primer inculding heating charges with cost of gas and hire charges of heating tourch etc |
| 40 | Zinc Allum Specification - Providing and fixing 0.5mm thick Zinc Allum sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 6.5 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length up to 12 metre or as desired by Engineering-charge. The sheet shall be fixed using self-drilling / self-tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. (Note: Actual Surface area of fabric shall only be measured for payment |
| 41 | Supplying, Providing, Fabricating, Assembling, hoisting, erecting and placing in position MS Built-up section/ Tubular Structure (MS) confirming to IS 2062 Grade Yst 250-350, Tubular Structure:- made from steel hollow sections, ISI marked from SAIL/ RINL/ TATA/ JINDAL, confirming to IS 1161/4923, Grade Yst 310, thickness upto 10mm) in the profile shape as per drawings with special plate connector, pinion joints, Plates, hollow sections, etc and applying a coat of epoxy primer, and including Preparation of detailed fabrication and erection drawings of Structural steel work from design drawings issued by Engineer- in- charge and incorporation of Engineer-in-Charge’s comments on same, transportation from fabrication yard, cutting, threading, machining, leads and lifts upto all heights, tools and plants and necessary scaffolding etc. required for all operations involved to make structure of Metal sheet roofing .The tubular structure system with plate connectors, pinion joints, etc must be sustained up to 250 km/hour wind pressure. The structure has to be provided as per conceptual drawings of metal shade. The work is to be executed as per technical specification and direction of Engineer-in-Charge. |
| 42 | Part-B (E.I Works)WiringRecessed wirring to light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor of ISI marked Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI with 20 mm dia HMS FRLS PVC conduit ISI marked Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal 6A modular type ( flame retradant type) switch ISI marked Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) and ceiling rose ISI marked of modular type G.I box with metallic cover plate (both side) ( flame retradant type) Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) of suitable size, modular box with 1.5 sq. Mm FRLS PVC insulated single core multistandard copper conductor as earth wire including all accessories and connection as per direction of Engineer -in -Charge. . All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials.Group A |
| 43 | Group B |
| 44 | Group C |
| 45 | Supply and fixing of ISI marked modular type 2nos 6Amp socket with switch on suitable size of metal box and modular cover in front on surface or recess including all conection as per direction of E.I.C. All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials. (Make :Legrand(Myrius)/Schnider(Zencelo)//PANASONIC(VISION) |
| 46 | Supply and fixing of modular metal box on surface or recess with suitable size of modular cover in front including providing an fixing of ISI marked 16Amp modular plug with switch with all conection. on surface or recess including all conection as per direction of E.I.C. All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials. (Make :Legrand(Myrius)/Schnider(Zencelo)//PANASONIC(VISION) |
| 47 | Supply& fixing of Modular type 6 Amp one way switch and 6 A socket outlet with metal box and modular cover Separate Board on surface or recess including all conection as per special conditions of contract making good the damages caused complete as per the direction of Engineer-in-charge. All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials. (Make :Legrand(Myrius)/Schnider(Zencelo)//PANASONIC(VISION)) |
| 48 | Supply, delivery, installation, testing and commssioning of modular type TV Antenna Outlet Boards containing a ISI marked Modular TV Antenna/Telephone Socket fixed on Modular Concealed Box including connections and making good the damages caused complete as required and as per Dierction of Engineer-In-Charge.. |
| 49 | Supplying and installation of AC Point having 16-20A DP MCB, C series with enclosure, Schneider/Siemens/Legrand/ABB of suitable size as required as per direction of Engg.-in-Charge .All the Components should be warrantied for a replacement period of 1 year against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 50 | Submains:Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 1.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor. In 20 mm dia non metallic heavy duty conduit (LDB to LSB/LIGHT CKT)(2X1.5+1X1.5) |
| 51 | 2 nos single core 2.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit.(BDB to LSB/LIGHT CKT/5A PLUG/UPS POINT ) (2X2.5+1X1.5) |
| 52 | 2 nos single core 4 sq. mm copper wire for phase and neutral and 01 no of single core 2.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit .(PDB to PSB/ POWER POINT/AC POINT) (2X4+1X2.5) |
| 53 | 2 nos single core 6 sq. mm copper wire for phase and neutral and 01 no of single core 2.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit .(PDB to PSB/ POWER POINT/AC POINT) (2X6+1X2.5) |
| 54 | Supplying and fixing of following sizes of medium class PVC FRLS conduit ISI marked along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required as per direction of Engg.-in-Charge .Make-AKG/ BEC/ Precision/ Norpak 20 MM |
| 55 | 25 MM |
| 56 | Supplying and fixing of following mentioned way, single pole and neutral, sheet steel,double door MCB distribution board, 415 volts/240 volts shall be as per IEC 61439-3,integrated door earthing system offering additional safety to the user,High quality polyurethane Gasket,the box and cover shall be fabricated to withstand IK09,the DB should be properly pre-treated with 7 tank process and duly powder coated, phosphatized with powder coated finish, on surface/recess, complete with terminal blocks,with suitable size FR PVC insulated copper conducter up to terminal blocks, tinned copper busbar, neutral busbar, earth bar, din bar. Make-LEGRAND-Ekinox3 DB/ Siemens-Betaguard/ Schneider- Acti 9 as per direction of Engg.-in-Charge. The Distribution boards should be Replacement Warranty will be 3 years.16 Way SPN MCB DD DB Horizontal Type as per IEC 61439-3 suitable for Flush mounting and Surface mounting with 63A Copper Bus Bar for each phase, with neutral Bus bar, Earth Bar & Cable ties for cable management, prefitted masking sheet, IP43-IK09 with metal door Warranty on DB is 3 years |
| 57 | Supplying and fixing 63 Amps rating,C series,10KA breaking capacity, DP, 240 volts, MCB 10kA . Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. . The MCB should be Replacement Warranty will be 3 years. |
| 58 | Supplying and fixing 6 amps to 32 amps rating, 240 volts, C series,10KA breaking capacity, single poles MCB of Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9. the existing MCB DB complete with connections as per direction of Engg.-in-Charge. .Warranty on MCB is 3 years. |
| 59 | Supplying and fixing of Energy efficient surface /recess mounted square /round shape 18 W LED luminaire of dimension of consists of white powder coated , die-cast Alluminium housing with high quality frosted diffuser for glare-free uniform lighting distribution with wattage not more than 18 watt and lumen output of 1800 lumens, , CRI not less than 80,CCT of 6000 degree K,THD less than 10%, with electronic driver, internal surge protection of 3 KV , L70 B50: 50000 hrs and all other accessories suitable for operation on 220 V to 240 V supply as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj).The luminaire should be Replacement Warranty will be 2 years |
| 60 | Supply of 20 watt surface mounted indoor type battern LED Luminaire with LED GLARE FREE opal diffuser , IP20 Efficency 120-130lm/w luminaire of dimension of consists of white powder coated , die-cast Alluminium housing with high quality frosted diffuser for glare-free uniform lighting distribution with wattage not more than 20 watt and lumen output of 1800 lumens, , CRI not less than 80,CCT of 6000 degree K,THD less than 10%, with electronic driver, internal surge protection of 3 KV , L70 B50: 50000 hrs and all other accessories suitable for operation on 220 V to 240 V supply as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj).The luminaire should be Replacement Warranty will be 2 years |
| 61 | Supplying, installation, of exhaust fan of heavy duty 300 mm sweep 1400 rpm 1700 cmh air delivery with louvers of exhaust fan in the existing wall, including fixing & conntection complete etc.as required and as per the direction of E.I.C..(Make-USHA (Model.Turbo HDEF 1400 RPM ISI)/Eq. model of /Havells/ ALmonrad/ Crompton |
| 62 | Supplying, installation, testing and commssioning of 1200 mm sweep BLDC ceiling fan with aluminium blades having wattage not more than 28W and Air delivery ≥ 215(m3/min) Make-USHA(Teohnix)/Crompton(Energion Groove)/Havells(Efficiencia Neo ) including wiring the down rod of standard length (upto 30 cm) with 1.5 sq mm PVC insulated, copper conductor, single core cable etc. as required as per direction of Engg.-in-Charge,Replacement Warranty will be 4 years.. .(With fan Regulator) |
| 63 | Supplying an fixing of recess/surface mounted 2'x2'(595mmx595mmx70mm(+/-5%) square shaped LED made up of CRCA powder coated housing with lumen efficacy not less than 140lm/W and lumen output not less than 3600 lumens , CRI not less than 80, CCT of 5700-6500 degree K, THD less than 10%,internal surge protection of 3 KV, complete with Non integrated isolated electronic driver (protects the output /secondary side from any disturbance on the input / primary side ensuring safe operation)and all other accessories suitable for operation on140- 270 V, 50 Hz ,L70 @50,000 burning hrs (5 years warranty) as required as per direction of Engg.-in-Charge (Make: Panasonic/ LT/ Havells / HALONIX/Philips/ Wipro/ Crompton/ Bajaj) . The luminaire must be Replacement Warranty will be 5 years. |
| 64 | SITC of 2 TR high wall 5 star inverter type split A.C machine (BTU/Hr-18000) with copper condensor & evaporator having ambient temperature 52 degree celcius with comprehensive 1 year warranty,5 years warranty on PCB, 5 years warranty on compressor.The rate is inclusive of 3 mtr copper refrigerant pipe. In case, the distance between ODU and IDU exceeds 3 mtr, then only the item of copper pipe shall be executed without any joint and equivalent mtr shall be deducted from the copper pipe item. (Make:O-General/Diakin/Mitsubishi/Hitachi) |
| 65 | Supply and fixing of 4kVA Voltage stabilizer (130-230V) (Make-V-Guard/Microtek) |
| 66 | Supply,installation of hard/soft ISI marked copper refrigerant piping of size 5/8 inch and 1/4 inch for suction and liquid line with 3 corex4 sqmm FRLS Copper control cable alongwith 25 mm weather proof closed cell nitrile insulation ,complete with fitting of bends and other nesessary material to complete the job. |
| 67 | Supply,installation & fabrication of MS base frame for outdoor unit and other nesessary material to complete the job. |
| 68 | Part-C (P.H Works)Supplying all materials, labour, T&P and providing and fixing to wall or ceiling and floor GI/PVC pipes, class-IV (10 k.g. F/cm) on firming I.S.4985 of the following nominal bore, tube fittings and clamps including making good the wall, ceiling and floor, testing all complete as per specification and direction of the Engineer in charge.20mm diaC PVC Pipe |
| 69 | F.Floor |
| 70 | 25mm dia PVC Pipe G.Floor |
| 71 | F.Floor |
| 72 | Supplying all materials, labour T&P and fitting and fixing brass/CP fittings of the following nominal bore with supply of all joiniting materials including cost & conveyance of all materials to worksite, payment of taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge.15mm dia CP angle stop cock (JaquarJaquar, hindwar,parryware Make) |
| 73 | 15mm dia CP two way bib cock (jaqJaquar, hindwar,parryware Make) |
| 74 | 15mm dia CP bib cock (jaqJaquar, hindwar,parryware Make( |
| 75 | 15mm dia long CP bib cock (jaq Make( |
| 76 | 25mm dia brass full way valve (Shakti make) (Plaza |
| 77 | 15mm dia CP Health Faucut (Jaquar Make) |
| 78 | 15mm CP Extension piece |
| 79 | 125mm CP grating |
| 80 | 15mm size C.P. flange |
| 81 | supplying all materials, labour, T&P and cutting holes through existing brick work including making good the damages in cement mortar (1:4) for taking G.I. Pipes and fittings/ P.V.C. pipes and fittings including watering, curing, cost & conveyance of all materials to worksite, payment of royality, taxes etc. all complete as per direction of Engineer-in-charge.In G.Floor |
| 82 | In F.Floor |
| 83 | Supplying all materials , labour, T&P and cutting holes in RCC floors and roofs upto 19cm thick for passing P.V.C pipes and G.I fittings etc. , and repairing the holes after insertion of pipe etc. with cement concrete (1:2:4) including finishing complete so as to make it leak-proof as per P.H. specification and direction of Engineer-in-charge |
| 84 | In F.Floor |
| 85 | Supplying all materials, labour, T&P and cutting grooves in pucca floors and walls for taking G.I./P.V.C. pipes and making good the damages including watering , curing , cost & conveyance of all materials to worksite, payment of royality, taxes etc all complete as per direction of the Engineer-in-charge.In G.Floor |
| 86 | In F.Floor |
| 87 | Supplying all materials, labour, T&P and fitting and fixing U-PVC SWR soil waste ventilating pipes and fittings of the following outside diameter conforming to ISI No 13592/1992 to walls with nails, bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricant by non-heat application method/as per manufacturer's specification, testing, earthwork in excavation in all kinds of soil and refilling of trenches , cost & conveyance of all materials to worksite, payment of taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge. 110mm U-PVC SWR Pipe (Ori Plast/Finolex/Supreme Make Type-B) |
| 88 | 110mm U-PVC ‘P’ Trap(Ori Plast/Finolex/Supreme Make) |
| 89 | 110mm U-PVC door bend(Ori Plast/Finolex/Supreme Make) |
| 90 | 110mm U-PVC Plain bend(Ori Plast/Finolex/Supreme Make) |
| 91 | 110mm U-PVC offset without ear(Ori Plast/Finolex/Supreme Make) |
| 92 | 110mm U-PVC Cowl(Ori Plast/Finolex/Supreme Make) |
| 93 | 110mm U-PVC S/J Door (Ori Plast/Finolex/Supreme Make) |
| 94 | 110mm U-PVC Plain tee(Ori Plast/Finolex/Supreme Make) |
| 95 | 110mm U-PVC Socket(Ori Plast/Finolex/Supreme Make) |
| 96 | Supplying all materials,labour,T&P and fixing Flat back lipped wall ( stall urinal -630mmx180mm) urinal of the following sizes including connecting the urinal with 32mm. dia pvc waste pipe 910mm. long by means of white lead mixed with chopped hemp, fixing 32mm. dia CP dome waste, 15mm. dia CP spreader including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc. all complete as per specification and direction of the Engineer in charge Half stall urinal |
| 97 | Supplying all materials, labour T&P and and fixing 12.50 liters/10 liters capacity low level flushing cistern with a pair of cast iron or M.S. brackets complete with fittings such as siphonic arrangements 15mm nominal size brass/pvc ball valve with polythene float CP brass handle,unions and couplings for connection with inlet, outlet and overflow pipes, 32mm dia CP long flush bend, 15mm dia pvc inlet connection pipe including cutting holes and making good the same and connecting the flush bend with cistern and closet and connceting the inlet pipe with suupply main , cost & conveyance of all materials to worksite, payment of taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge10 ltr. Capacity pvc L.L. cistern with 32mm. Dia CP long flush bend ( Slimline-white-Parryware make ) |
| 98 | Supplying all materials, labour, T&P and fixing vitreous china water closet, squatting pan (Indian type W.C pan/Orissa pattern squatting pan) duly embedded in cement concrete (1:5:10) using 4cm size hard granite metal including fixing a pair of vitreous china 250mm x 130mm x30mm footrest, fixing 100mm dia HCI 'p' or 's' trap (with/without 50mm dia horn) for water colset squatting pan including jointing the trap with pan in cement mortar (1:1) cutting the floor and mending good the damages , cost & conveyance of all materials to worksite, payment of royality , taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge.Ewc (Hindware/Parryware/Neycer make) |
| 99 | Supplying all materials, labour T&P and fixing wash basins with hole for pillar taps with cast iron or M.S.brackets painted white including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc, fixing pedestal for wash basin recessed at the back for the reception of pipes and fittings, fixing PVC waste pipe of 32mm nominal diameter for wash basin including brass check nut complete, fixing pillar taps capstan head screw down high pressure lettered 'Hot' and 'Cold' with long screws, shanks and back nuts of 15mm dia nominal bore, fixing 15mm dia PVC inlet connection pipe and making connection with pillar cocks and supply mains for wash basin, fixing 32mm dia CP brass waste, cost & conveyance of all materials to worksite, payment of taxes etc. all complete as perP.H specification and direction of the Engineer-in-charge550mmx400mm W.H.basin (Hindware/Parryware/Neycer make)with 15mm dia C.P.pillar cock (Jaquar make) with |
| 100 | Supplying all materials, labour, T&P and fixing standard sized CP towel rail complete with CP brass brackets fixed to wooden plugs with CP screws as per specification and direction of the Engineer in charge25mmx600mm long CP towel rail |
| 101 | Towel ring |
| 102 | Supplying all materials, labour, T&P and fixing standard sized glass-shelf with CP brass brackets and guard rail complete fixed to wooden plugs with CP screws as per specification and direction of Engineer in charge.600mmx125mm plate glass shelf with CP/NP guard rails. |
| 103 | Supplying all materials, labour, T&P and fixing mirror of superior glass mounted on 6mm.thick A.C. sheet or ply wood sheet and fixed to wooden plugs with CP screws and washers complete as per specification and direction of Engineer in charge.600mmx450mm size B.E mirror (swivelled type) |
| 104 | Supplying all materials, labour, T&P and fixing CP soap holder complete with CP brass brackets fixed to wooden plugs with CP screws as per specification and direction of the Engineer in chargeCP soap holder |
| 105 | Supplying all materials ,labour ,T&P and constructing Inspection Chamber of inside size 760mmx760mmx460mm with cement concrete (1:3:6) using 40mm size crusher broken hard black granite metal on bed , Fly Ash brick work in cement mortar (1:6) in foundation and plinth, moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size crusher broken hard black granite chips, 12mm thick cement plaster (1:3) with cement punning to inside, cement flush pointing (1:3) to outside, R.C.C cover slab (1:2:4) using 12mm size crusher broken hard black granite chips with R.C.C man hole cover, earth work in excavation in all kinds of soil and refilling the cavity around the chamber including watering,curing,cost of all materials, conveyance of all materials to worksite, payment of royalty,all taxes etc.all complete as per approved drawing, P.H specification and direction of Engineer-in-charge88.10 Inside size 76cmx76cmx46cm with 18” dia RCC MH coverInsids size 76cmx76cn with 18* dia RCC MH cover |
| 106 | Supplying all materials, labour, T&P and providing cement concrete ( 1:4:8 ) with 40mm size crusher broken hard black granite mental including watering, curing,cost of all materials, conveyance of all materials to work site with payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge G.Floor |
| 107 | Supplying all materials, labour, T&P and providing cement concrete ( 1:2:4 ) with 12mm size crusher broken hard black granite Chips including watering, curing,cost of all materials, conveyance of all materials to work site with payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-chargeIn F.Floor |
| 108 | Supplying all materials, labour, T&P and providing and fixing ceramic tiles in floors, treads or steps and landing on 25mm thick bed of cement mortar (1:1) ( 1 cement : 1 sand ) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including watering, curing,cost of all materials, conveyance of all materials to work site , payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge ( vetrified matt finished floor tiles of premium grade having thickness 7mm to 8mm conforming to IS 13755 of size 30cmx30cm special printed series to be pre-approved by the Engineer-in-charge ) Kajaria tile 30cmx30cm Ground FLoor |
| 109 | In F.Floor |
| 110 | Supplying all materials,labour,T&P and providing 12mm thick cement plaster(1:4) on brick work including watering,curing,cost of all materials, conveyance of all materials to worksite,payment of royalty,all taxes etc.all complete as per PWD specification and direction of the Engineer-in-charge.G.Floor |
| 111 | In F.Floor |
| 112 | Supplying all materials, labour, T&P and providing and fixing porcelain glazed tiles in dado skirting on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including watering, curing,cost of all materials, conveyance of all materials to work site , payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge( vetrified wall tiles of premium grade having thickness 6.5mm to 6.7mm conforming to IS 13753 of size 60cmx30cm special plain / printed series to be pre-approved by the Engineer-in-charge )Kajaria glazed tile 45cmx30cm G Floor |
| 113 | In F.Floor |
| 114 | Supplying all materials, labour, T&P and laying in trenches (to level or slope) unplasticized P.V.C. pipe conforming to IS 4985/2000 of the following out side dia for class- 3 (0.60mpa ) including jointing with supply of approved solvent cement by non-heat application method/as per manufacture's specification, provoding and laying in trench cement concrete (1:4:8) with 40mm size hard granite metal in the type C-1 standard bedding surrounding or encasing including concrete for bedding and curing etc all complete as per P.H. specification and direction of the Engineer in charge100mm dia P.V.C. pipeall round concrete pipe Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail