| Sl. No. | Item Description |
| 1 | CIVIL WORKDismantling and removing doors, windows and ventilators including removal of frame, hinges, fastening and stacking the same for reuse and removing the debris within 50m lead including cost of all labour with T&P etc. complete as per the specification and direction of the Engineer-in-charge.(a)Ground Floor |
| 2 | Dismantling brick or stone masonry in lime or cement mortar above 3m height including stacking the useful materials for re-use and removing the debris with in 50m lead including cost of all labour with T&P etc. complete as per the specification and direction of the Engineer-in-charge.(a)Ground Floor |
| 3 | Clearing and grubbing roads and land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, up to a lead of 1000 metres including removal and disposal of top organic soil not exceeding 150 mm in thickness.(a)Ground Floor |
| 4 | Providing 375mm dia and 9.00m long, single under reamed bored compaction RCC Pile with M-25 grade concrete including cost of boring to required dia meter and depth to plumb and taking precautionary measure against collapsing of side soil due to presence of water table using bentonite powder etc., concreting and driving the cage made of M.S. / T.S. steel as per approved drawing into the freshly laid concrete vertically by means of power winch to requied depth but excluding cost of M.S. / T.S. steel and labour charges for cutting, bending and binding of steel etc. complete confirming to IS-2911 specification including necessary routine tests including cost, conveyance, royalties and taxes of all materials with labour,labour cess and T&P etc. required for the work complete as per the specification and instruction of Engineer-in-Charge.(a)Ground Floor |
| 5 | Earth work in excavation of foundation in all kinds of soil within 50m initial lead and 1.50m initial lift including rough dressing breaking clods maximum 5cm to 7cm & laying in layers not exceeding 0.3m depth for the work complete including shoring, shuttering & dewatering (if required) with cost of all Labour, Labour cess ,Hire & Running charges of the water pumps, Sundries, T & P required for the work complete as directed by the Engineer- in- charge.(a)Ground Floor |
| 6 | Filling in foundation trenches and plinth, with excavated earth including laying the earth in layers not exceeding 23.5 cm thick ramming & watering with all leads & lifts including cost of all labour,T&P completed as directed by the Engineer-in-charge. (a)Ground Floor |
| 7 | Supplying and filling in foundation and plinth with good quality river sand including watering, ramming with cost, conveyances, royalties of all materials and cost of all labour with T&P required for the work etc. complete as per specification & direction of Engineer-in-charge(a)Ground Floor |
| 8 | Providing & applying of pre constructional anti-termite treatment by drilling 12mm dia holes at distance of 30cm @ junction of wall & floor about 300mm apart deep enough to reach the soil below & chemical emulsion (IMIDACHLOPRIED 30.5SC mixed with 47.5ltr water) pumped these holes to soak the soil @ 1 ltr solution of each hole as per manufactures specification & the holes should be pluged the filling materials including cost of all materials, labour,conveyance, T&P , all taxes and hire charges of machinaries as per direction of Engineer-in-charge.(a)Ground Floor |
| 9 | Providing and laying plain cement concrete of proportion (1:3:6) in foundation and floors using 4 cm. size black hard crusher broken granite stone metal and screened and washed sharp sand for mortar of approved quality and from approved quarry including hoisting, lowering, laying concrete, ramming, watering and curing etc. complete to required levels laid in layers not exceeding 15 cm. thick in each layer including cost, conveyance, royalties of all materials and cost of all labours,labour cess, T&P etc complete as per the direction of the Engineer-in-charge.(a)Ground Floor |
| 10 | Providing, lifting, hoisting and laying Reinforced cement concrete of M-25 grade as per approved designs and drawings having a minimum compressive strength (in work test) 250 Kg. / Square cm. in 15 cm. cubes at 28 days after mixing and test conducted in accordance with I.S. 516 using 12 mm. to 20 mm. size black hard crushed broken granite stone chips and screened and washed sharp sand for mortar of approved quality from approved quarry, washed and cleaned ( 20mm. size chips not to exceeds 25 % ) to be mixed in concrete mixture with Portland slag cement (PSC) including hoisting, lowering, laying and compaction concrete by using vibrators, watering and curing for 28 days, centering and shuttering then after dismantling and removing debris from the work site and finishing the exposed surface smooth providing grooves or beads wherever necessary including cost, conveyance, loading, unloading, royalties and taxes of all materials and cost of all labours, sundries, T & P required of the work etc. complete in all respect as directed by the Engineer-in-Charge. But excluding cost and conveyance of M.S. rods or Tor steel and binding wires and labour charges for straightening, cutting, bending etc. of M.S. rods or tor steel tying the grills and placing in proper position.R.C.C. Foundation and Footing Bases of Columns Mass Concrete Pre-Cast Slab etc. |
| 11 | R.C.C. Grade Beams |
| 12 | R.C.C. Columns & Roof Beams(a)Ground Floor |
| 13 | (b)First Floor |
| 14 | (c)Second Floor |
| 15 | (d)Terrace Floor |
| 16 | R.C.C. Lintels(a)Ground Floor |
| 17 | (b)First Floor |
| 18 | (c)Second Floor |
| 19 | (d)Terrace Floor |
| 20 | R.C.C. Chajja(a)Ground Floor |
| 21 | (b)First Floor |
| 22 | (c)Second Floor |
| 23 | (d)Terrace Floor |
| 24 | R.C.C. Shelve(a)Ground Floor |
| 25 | (b)First Floor |
| 26 | (c)Second Floor |
| 27 | R.C.C. Stair Case(a)Ground Floor |
| 28 | (b)First Floor |
| 29 | (c)Second Floor |
| 30 | R.C.C. Floor and Roof Slab, Landing, Balconies, Projecting Sun Shades and Chajjas up to 4.3 Mtr. Height.(a)Ground Floor |
| 31 | (b)First Floor |
| 32 | (c)Second Floor |
| 33 | (d)Terrace Floor |
| 34 | R.C.C. Retaining Wall(a)Ground Floor |
| 35 | (b)Terrace Floor |
| 36 | Supplying Cutting, straightening coiled or bent up M.S. Rod or tor steel of primary steel producers such as SAIL / Tiscon / RINL / JINDAL STEEL / SHYAM STEEL (grade Fe-500D) etc. including bending, binding, welding, wastage & over lapping and jointing if necessary and tying the grills and placing in position as required for R.C.C. Work and for providing fan hooks as required, hoisting, lowering, laying including cost, conveyances of M.S. Rod or tor steel and binding wires of 18 to 20 gauge and labour required for the work for bending, binding and tying the grills in all floors with labour cess etc. (payment will be made on standard weight of B.I.S. for M.S. Rods or tor steel only) etc. complete as per specification & direction of Engineer-in-charge.(a)Ground Floor |
| 37 | (b)First Floor |
| 38 | (c)Second Floor |
| 39 | (d)Terrace Floor |
| 40 | Fly Ash brick masonry in cement mortar (1:6) in foundation & plinth using Fly Ash bricks of 25 x 12 x 8 cm size having a crushing strength of not less than 75 kg./sqcm with dimensional tolerance ± 2% including splays cutting circular moulding chamfering and corbelling and similar such type of works with all necessary projections watering and curing after immersing the bricks in water at least for six hours before use including cost, conveyance, royalties of all materials with all labour,labour cess and T & P required for the work complete in all respect as per direction of Engineer-in-Charge.(a)Ground Floor |
| 41 | Fly Ash brick masonry in cement mortar (1:6) in super structure using Fly Ash bricks of 25 x 12 x 8 cm size having a crushing strength of not less than 75 kg./sqcm with dimensional tolerance ± 2% including splays cutting circular moulding chamfering and corbelling and similar such type of works with all necessary projections watering and curing after immersing the bricks in water at least for six hours before use including cost, conveyance, royalties of all materials with all labour,labour cess and T & P required for the work complete in all respect as per direction of Engineer-in-Charge.(a)Ground Floor |
| 42 | (b)First Floor |
| 43 | (c)Second Floor |
| 44 | (d)Terrace Floor |
| 45 | Fly Ash brick masonry in cement mortar (1:4) in super structure using Fly Ash bricks of 25 x 12 x 8 cm size having a crushing strength of not less than 75 kg./sqcm with dimensional tolerance ± 2% including splays cutting circular moulding chamfering and corbelling and similar such type of works with all necessary projections watering and curing after immersing the bricks in water at least for six hours before use including cost, conveyance, royalties of all materials with all labour,labour cess and T & P required for the work complete in all respect as per direction of Engineer-in-Charge.(a)Ground Floor |
| 46 | (b)First Floor |
| 47 | (c)Second Floor |
| 48 | Providing 16 mm thick cement plaster with cement mortar of mix (1:6) with screened and washed sharp sand for mortar and finished smooth to the rough surface of walls in all heights after racking out joints including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance, royalties of all materials with cost of all labour,labour cess, T&P, and scaffolding required for the work etc. complete in all respect as directed by the Engineer in charge. (a)Ground Floor |
| 49 | (b)First Floor |
| 50 | (c)Second Floor |
| 51 | (d)Terrace Floor |
| 52 | Providing 12 mm thick cement plaster with cement mortar of mix (1:6) with screened and washed sharp sand for mortar and finished smooth to the rough surface of walls in all heights after racking out joints including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance, royalties of all materials with cost of all labour,labour cess, T&P, and scaffolding required for the work etc. complete in all respect as directed by the Engineer in charge. (a)Ground Floor |
| 53 | (b)First Floor |
| 54 | (c)Second Floor |
| 55 | (d)Terrace Floor |
| 56 | Providing 12 mm thick cement plaster with cement mortar of mix (1:4) with screened and washed sharp sand for mortar and finished smooth to the rough surface of walls punning and bitumen coating including watering and curing with cost, conveyance, royalties of all materials with cost of all labour, and T&P required for the work etc. complete in all respect as directed by the Engineer in charge.(a)Ground Floor |
| 57 | (b)First Floor |
| 58 | (c)Second Floor |
| 59 | Providing 6 mm thick cement plaster with cement mortar of mix (1:4) with screened and washed sharp sand for mortar and finished smooth to R.C.C. work after closed deep chipping & slurry treatment including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance, royalties of all materials with cost of all labour, T&P, and scaffolding required for the work etc. complete in all respect as directed by the Engineer in charge.(a)Ground Floor |
| 60 | (b)First Floor |
| 61 | (c)Second Floor |
| 62 | (d)Terrace Floor |
| 63 | Providing & Fixinng factory made 100% Solid WPC (Wood Polymer Composite)- Door Frame 125 mm x 65 mm Single Rebated, made from Wood Polymer Composite ( Single Extruded Process ) material comparising of virgin PVC polymer of K Value 57-60 ( Suspension Grade ), Calcium Carbonate and Natural Fibers (Wood Powder/ Rice Husk/ Wheat Husk ) and Non toxic additives fabricated with meter Joints after applying PVC solvent Cement & screwed with full body treaded star headed screws having minimum frame density of 780 kg/ cbm & an ISO 9001 - 2015 Certified Company, having good screw holding capacity ( Screw Withdrawal strength of (Min. 990 N), Minimum Compressive Strength of 58 N/mm2, Modulus of elasticity 900N/mm2 and resistance to spread of flame of class A category with property of being termite / borer proof , water / Moisture Proof & Fire retardant & Fixed in position with SS Dash Fasteners / Hold Fast of reuired dia and lenght, , all as per specifications drawings as directed by the Engineer-In-Charge. Material test certificate and authentication should be compulsory provided by the manufacturing company. (Make-Green Land / Century/ Alstone)(a)Ground Floor |
| 64 | (b)First Floor |
| 65 | (c)Second Floor |
| 66 | (d)Terrace Floor |
| 67 | Supplying, fitting and fixing of 32mm thick flush door shutter with approved quality of 30mm thick BWR block board pasted with 1mm thick sunmica on both side of approved design and quality including cost of all door fittings and fixtures etc. complete as per the direction of Engineer-in-Charge.(a)Ground Floor |
| 68 | (b)First Floor |
| 69 | (c)Second Floor |
| 70 | Factory made Single extruded WPC (Wood Polymer Composite) solid plain flsush door shutter 30 mm thick including the cost of all materials, labour, conveyance, taxes, loading, unloading, T&P, etc. all complete as per the direction of Engineer-in-Charge.(Make-Green Land / Century/ Alstone)(a)Ground Floor |
| 71 | (b)First Floor |
| 72 | (c)Second Floor |
| 73 | (d)Terrace Floor |
| 74 | Supplying , fitting and fixing of openable UPVC doors with door frame of approved make with 6mm thick glass of approved quality complete with frame, shutters and all fitting and fixtures as per the direction of Engineer-in-Charge.(Make-FENESTA/ Koemmerling/ Saint Gobain/ Prominance) (a)Ground Floor |
| 75 | (b)First Floor |
| 76 | (c)Second Floor |
| 77 | FIRE RATED DOOR:Providing and fixing ISI Marked un-insulated fire rated door confirming to IS 3614: 2021, & tested to IS17518,and shall carry a unique label with certification/test report number. The fire rating shall be for 120minutes integrity only. Material shall be galvanised steel conforming to IS 277, made out of minimum 1.2 (18 SWG) for both frame and shutter, G.I. sheet (zinc coating 120 gsm/sqm) Frame shall be 125 x 55 grooved profile with built in rebate for fire rated smoke seal. Frame shall be mitered and field assembled. EPDM smoke seal to be provided along with frame as standard. Door shutter shall be double skin of 46mm thick with required fire rating and with vision panel. The infill material shall be resin bonded honeycomb core. All doorset shall be factory prepped for receiving appropriate hardware and provided with necessary reinforcement for hinges, locks and door closers. The door stiles should be interlocked, for pairs of doors integral astragals has to be provided on the meeting stile for both active and inactive leaf. Vision lite, minimum 5mm clear fire rated glass of size 150 x 750mm (max 0.12sq.mt) on both shutters, fixing with clipon arrangement. All frame and door shutter shall be finished polyster powder coated to minimum 50microns, of approved colour as per the direction of the engineer incharge. Cost of double leaf doorset shall include following hardware and accessories as a complete assembly. SS ball bearing hinges of SS304 grade of size 100x75x3mm, 1no Fire rated mortise dead lock, 55mm BS, 20mm sq. forend, including escutheion, sss as per EN 12209 with both side key cylinder on active leaf and 2nos flush bolt on the inactive leaf in case of double leaf door along with dust proof socket at bottom, 1pairs Pull handle D type, 22dia, CTC 300mm, back toback per leaf, with spindle, SS 304, SS finish. 1no of Door closer with spring size of EN 2-4, as per EN1154 and CE marked per leaf. Suitable anchor fastners for fixing on different type of wall construction as per manufacturer recommendation. Once frames is installed it shall be filled with fire rated PUF. Manufacturer test certificates shall covers complete door set as a un-latched assembly with a valid test certificate not exceeding 5 years from the date of issue of report. for more info refer doors details drawings, including cost of all materials, all labour, sundries, T&P etc. complete in all respect as per direction of Engineer-in-Charge.(a)Ground Floor |
| 78 | (b)First Floor |
| 79 | (c)Second Floor |
| 80 | Supplying, fitting and fixing of G.I. grills in windows & gate made out of G.I. flat confirming to IS : 2062/2006 painted with red oxide primer including screws as required including the cost of all materials, labour, conveyance, taxes, loading, unloading, T&P, etc. all complete as per the direction of Engineer-in-Charge.(a)Ground Floor |
| 81 | (b)First Floor |
| 82 | (c)Second Floor |
| 83 | (d)Terrace Floor |
| 84 | Supplying and instaalling UPVC-3 tracks sliding windows and 2 sashes (shutters) with ss mesh sash dimension of 58 mm x 32mm and sash dimension of 61mm x 37mm for windows with corners fusion welded, fully reinforced with Galvanized steel of 1.2 mm to 2 mm. The sash will be fitted with 5mm reflective toughened glass of make - Saint gobain/AIS/Goldplus. The windows must be installed complete with all kinds of ironmongery (including EPDM gaskets, bridging wedges and glass packers) and with suitable water draining system. Application of Silicon sealant from Inside / Outside of Dowcorning / GE or equivalent including cost of all materials, all labour, sundries, T&P etc. complete in all respect as per approved drawing & direction of Engineer-in-Charge.(Make-FENESTA/ Koemmerling/ Saint Gobain/ Prominance).(a)Ground Floor |
| 85 | (b)First Floor |
| 86 | (c)Second Floor |
| 87 | (d)Terrace Floor |
| 88 | Supplying , fitting and fixing of two track UPVC sliding window of approved make with 6mm thick glass of approved quality complete with frame, shutters and all fitting and fixtures etc. complete in all respect as per approved drawing & direction of Engineer-in-Charge.(Make-FENESTA/ Koemmerling/ Saint Gobain/ Prominance) (a)Ground Floor |
| 89 | (b)First Floor |
| 90 | (c)Second Floor |
| 91 | GRC JALIProviding and fixing Glass Reinforced Concrete (G.R.C) Screens in approved size, pattern, design, shadeand thickness of 50mm on frame and design element in 30mm thick have weight approximately between 3.5 4 Kg per Sq. Ft. and color of M/S UniStone make or equivalent. The above weight and thickness is considering dimensions of screens up to 2133mm in height and 1219mm in width and having at least 50% void space. The screens should be made from 53 grade White Portland Cement manufactured by JK Cement or equivalent, Quartz, Fine Silica Sand, Alkali Resistant Glass Fiber manufactured by N.E.G JAPAN or equivalent, Super Plasticizers manufactured by BASF or equivalent, Polymers manufactured by BASF or equivalent and U.V resistant Synthetic inorganic pigments should be used for pigmentation manufactured by BAYFERROX (Germany) or equivalent. The material casting should take place in FRP Molds. The fixing of Screens should be Dry fixing i.e. to be done with M.S Galvanized Clamps, fixtures and fasteners of Hilti Fischer.(a)Ground Floor |
| 92 | (b)First Floor |
| 93 | (c)Second Floor |
| 94 | Supplying, fitting and fixing of Stainless steel of 304 grade in hand railing using 50mm dia of 2mm thick circular pipe with Balustrade of size 32mm x 32mm x 2mm @ 0.90mtr. C/C and stainless square pipe bracing of size 32mm x 32mm x 2mm in 3 rows in stair case as per approved design and specification, buffing, polishing etc with cost, conveyance, cost of all labour,labour cess, T&P etc. required for the work complete in all respect as per direction of the Engineer-in-charge. (Make-JINDAL )(a)Ground Floor |
| 95 | (b)First Floor |
| 96 | (c)Second Floor |
| 97 | (d)Terrace Floor |
| 98 | Supplying, fitting and fixing vetrified tiles of premium grade having thickness 8mm to 10mm confirming to IS 13756 of size 600mm x 600mm plain (Ivory) of approved make(JOHNSON / SOMANY/ KAJARIA/ RAK) in floors on 20mm thick bed of C.M. (1:4) (1cement:4course sand) and filling the joint with white cement mixed with pigment to match the shades of the tileincluding cost of all materials, labour, labour cess, T&P etc. required for the work complete in all respect as directed by the Engineer in charge.(a)Ground Floor |
| 99 | (b)First Floor |
| 100 | (c)Second Floor |
| 101 | Providing, fitting, fixing vitrified tiles of premium grade having thickness 8mm to 10mm confirming to IS 13756 of size 600mm x 600mm plain (Ivory) of approved make (JOHNSON /RAK / SOMANY/ KAJARIA or equivalent ) as directed by Engineer-in-charge in dados skirting and risers of steps on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including rubbing and polishing etc. complete with cost, conveyance, royalties of all materials all labour,labour cess complete in all respects as directed by the Engineer in charge.(a)Ground Floor |
| 102 | (b)First Floor |
| 103 | (c)Second Floor |
| 104 | Fixing granite tiles of approved dimension area above 0.4 sqm (20mm thick) in floor, treads of steps and landing on 20mm thick bed of cement mortar (1:4) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including rubbing and polishing etc. complete with cost, conveyance, royalties of all materials complete in all respects as per direction of Engineer-in-Charge.(a)Ground Floor |
| 105 | (b)First Floor |
| 106 | (c)Second Floor |
| 107 | (d)Terrace Floor |
| 108 | Fixing granite tiles of approved dimension area above 0.1 Sqm & upto 0.4 sqm (20mm thick) in Dados, treads of steps and landing on 12mm thick cement mortar (1:3) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including rubbing and polishing etc. complete with cost, conveyance, royalties and taxes of all materials complete in all respects as per direction of Engineer-in-Charge.(Note- Sample of tiles shall be approved before procurement and use.)(a)Ground Floor |
| 109 | (b)First Floor |
| 110 | (c)Second Floor |
| 111 | (d)Terrace Floor |
| 112 | Providing & laying Granite Stone Flooring using 20 mm thick Granite Stone Slab of approved quality, colour and size between 0.4 Sqm. to 1.0 Sqm. & above in Stair Case Treads and Risers over an under layer of 20 mm thick cement mortar (1:4) (1 cement: 4 coarse sand) confirming to IS-1443/1972 including cutting to size, laying and joining with white cement slurry and colouring pigment to match the shade including cost of all labour, materials,royalties, loading and unloading, conveyance, sundries, watering and curing, making three nos horizontal grooves in treads etc. complete as per the direction of the Engineer-in-Charge.(Note- Sample of stone tiles shall be approved before procurement and use.)(a)Ground Floor |
| 113 | (b)First Floor |
| 114 | (c)Second Floor |
| 115 | Fixing of Kota tiles of minium thickness 16mm thick of premium grade of size above 0.10 Sqm. in floors over 20mm thick bed of cement mortar 1:4 (1cement:4course sand)and filling the joint with white cement mixed with pigments to match the shade of the tiles, including rubbing & polishing etc. complete including cost, conveyance, royalties of all materials, labour,labour cess with T&P complete in all respects as per direction of Engineer-in-Charge.(a)Ground Floor |
| 116 | Fixing of Kota tiles of minium thickness 16mm thick of premium grade of size above 0.10 Sqm. in Dado over 12mm thick bed of cement mortar 1:3 jointed with cement slurry mixed with pigments to match the shade of the tiles, including rubbing & polishing etc. complete including cost, conveyance & royalties of all materials, labour,labour cess with T&P complete in all respects as per direction of Engineer-in-Charge. |
| 117 | Finishing plastered surfaces of walls with cement based wall putty (Water based) of approved make (JK White/ Birla white or equivalent make duly approved by Engineer-in-Charge) and finishing the surface smooth and even by sand papering to receive painting in walls, at all heights with staging wherever necessary with cost, conveyance, cost of all labour,labourcess, all T&P etc. required for the work complete in all respect as per the direction of the Engineer-in-charge. (a)Ground Floor |
| 118 | (b)First Floor |
| 119 | (c)Second Floor |
| 120 | (d)Terrace Floor |
| 121 | Painting two coats with plastic emulsion paint with a approved quality primer to make an even finished surface in all floors and heights to wall surface of approved make and shade including sand papering, applying putty wherever necessary & cost of scaffolding, staging charges with cost, conveyance, cost of all labour,labour cess, T&P etc. complete as per the direction of the Engineer-in-charge.(Make: Asian/ Berger/ Dulux/ Nerolac or equivalent make duly approved by Engineer-in-Charge).(a)Ground Floor |
| 122 | (b)First Floor |
| 123 | (c)Second Floor |
| 124 | (d)Terrace Floor |
| 125 | Wall painting two coats with Antifungal weather coat paint (1st quality) exterior grade of approved make & approved shade over a coat of primer to make an even finished surface in all floors and heights with all scaffolding and staging charges including cost, conveyance, cost of all labours, T & P, sundries etc. as required for the work complete in all respect as per the direction of the Engineer-in-Charge.(Make: Asian/ Berger/ Dulux/ Nerolac or equivalent make duly approved by Engineer-in-Charge).(a)Ground Floor |
| 126 | (b)First Floor |
| 127 | (c)Second Floor |
| 128 | (d)Terrace Floor |
| 129 | Painting two coat with approved synthetic enamel paint to new wood work over a coat of Red oxide primer including cost, conveyances, royalties, taxes of all materials and cost of all labour with T&P required for the work etc. complete as per specification & direction of Engineer in charge.(Make: Asian/ Berger/ Dulux/ Nerolac or equivalent make duly approved by Engineer-in-Charge)(a)Ground Floor |
| 130 | (b)First Floor |
| 131 | (c)Second Floor |
| 132 | Painting two coat with approved synthetic enamel paint to new iron work over a coat of Red oxide primer including cost, conveyances, royalties, taxes of all materials and cost of all labour with T&P required for the work etc. complete as per specification & direction of Engineer in charge.(Make: Asian/ Berger/ Dulux/ Nerolac or equivalent make duly approved by Engineer-in-Charge)(a)Ground Floor |
| 133 | (b)First Floor |
| 134 | (c)Second Floor |
| 135 | (d)Terrace Floor |
| 136 | EXPANSION JOINT:Providing, fitting and fixing of Sikadur Combiflex SG 20P 200 and sealed by Sikadur 31C @ 1.4kg per meter over the expansion joints after cleaning the joints and applying of Sikadur 32 @ 200 gms per meter Epoxy bonding agent and levelled by Sikagrout 214 @ 8kg per meter and covered with 300mm wide 16 gauge Aluminium sheet complete including cost, conveyance, taxes of all materials, labour, transportation charges etc as per specification and direction of the Engineer-in-charge. Make-Fosroc/Myk/Equivalent(a)Ground Floor |
| 137 | (b)First Floor |
| 138 | (c)Second Floor |
| 139 | (d)Terrace Floor |
| 140 | GYPSUM CEILING.Providing and fixing False ceiling as per Saint Gobain Specifications made of standard G.I. Sections and 12mm thick gyp board sheets inclusive of all hangers, edge members and other clips complete, with sheets fixed with proper Philip fastner by power drills and joints duly finished ensuring level in line, complete with putty, primer and painting of approved make and colour. Cost includes cutouts for electrical fittings, materials, labour, T&P etc complete as per direction of the Engineer-in-charge. (Basic Rate of Gypsum Board 12mm thk. Rs.303/ sheet).(a)Ground Floor |
| 141 | (b)First Floor |
| 142 | (c)Second Floor |
| 143 | Providing and fixing false ceiling at all heights with integral densified calcium silicate reinforced with fibre and natural filler false ceiling tiles of Size 595x595mm of approved texture, to be laid in true horizontal level suspended on inter-locking metal T-Grid of hot dipped galvanised iron section of 0.33mmthick (galvanized @ 120 grams per sqm including both sides) comprising of main-T runners of size 24x38 mm of length 3000 mm.cross T of size 24x32 mm of length 1200 mm and secondary intermediate cross-T of size 24x32 mm of length 600mm to formgrid module of size 600 x 600* mm, suspended from ceiling usinggalvanised mild steel items (galvanizing @80 grams per sqm) i.e. 12x50 mm long dash fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 76x25×25x1.6 mm fixed with grid and Z cleat of size 25x37x25x1.6mm thick with precut hole on both 25mm flange to pierce into 12x50mm or even bigger size dash fastener if require, fixed with Glavanised iron perimeter wall angle or size 24x24x0.40 mm of length 3000 mm to be fixed on periphey wall/ partition with the help of plastic rawl plugs at 450mm center to center and 40 mm long dry wall S.S screws. The workshall be carried out as per specifications, drawing and as per directionsof the Engineer-in-Charge(a)Ground Floor |
| 144 | (b)First Floor |
| 145 | (c)Second Floor |
| 146 | Providing and laying 25mm thick grading Concrete of proportion (1:2:2) using 6mm size crusher broken black hard granite chips from approved quarry, scraping and cleaning the surface, fininishing smooth to proper slope and gradient including cost of all materials, cost of labour, conveyance, taxes, loading, unloading, curing,T&P, etc. all complete as per the direction of the engineer-in-charge.(a)Terrace Floor |
| 147 | E.I. WORKRecessed wiring to light point/ fan point/Exhaust fan point/Call bell point with 1.5sqmm FRLS PVC Insulated single core multistarand copperConductor of ISI marked with 20mm dia non metalic PVC conduit with 6A 250V MODULAR type switch ISI marked and ceiling rose marked mounted on Modular GI Box having front modular base plate of suitable size, with 1.5sqmm FR PVC Single core multistrand copper conductor as earth wire includingall accessories and connection as per direction of Engineer in charge (Make of wire Finolex / Havells /Polycab) (PVC Conduit Make: AKG, Sudhakar, Precision) (switch /socket/modular GI Board (Make: legrand (Mylinc)/schneider (clipsal)/hager (Insysta)) light pointGroup-A |
| 148 | -do- light point Group-B |
| 149 | -do- light point Group-C |
| 150 | -do- Fan point Group-B |
| 151 | -do- Fan point Group-C |
| 152 | -do- Call bell Point Group-C |
| 153 | Recessed wiring to 6 AMP Modular socket out let with 2x1.5sq mm for FRLS PVC insulated single core multistrand copper conductor of ISI marked in reccess 20mm dia non metalic PVC conduit Modular GI Box and earthing point with 1x1.5sqmm FR PVC insulated single core multistarnd copper conductor for loop earthing etc,as required complete in all respect as per direction of Engineer in charge (Make of wire Finolex / Havells /Polycab) switch /socket/modular GI Board Separate Point (Make: legrand (Mylinc)/schneider (clipsal)/hager (Insysta)) |
| 154 | On Existing board- |
| 155 | Supplying,fixing of 2X 6A Plug on the separate board with complete fitting by 02 no of 6A switch & socket(modular type) ( with suitable size modular box & metallic cover plate (both side)including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge. (Make: legrand (Mylinc)/schneider (clipsal)/hager (Insysta))(For equipement power). (Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials. |
| 156 | Supplying,fixing of 3X 6A Plug on the separate board with complete fitting by 03 no of 6A switch & socket(modular type) ( with suitable size modular box & metallic cover plate (both side)including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge. (Make: legrand (Mylinc)/schneider (clipsal)/hager (Insysta))(For equipement power). (Maximum 03 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials. |
| 157 | Supply and fixing of Modular metal box on surface or in recess with suitable size of Modular cover in front including providing and fixing of 3pin, 16Amp socket outlet and 16Amp Modular switches connection as required complete in all respect as per direction of Engineer in charge (Make: legrand (Mylinc)/schneider (clipsal)/hager (Insysta)) |
| 158 | Supplying,fixing of 1x6A and 1x16A Plug on the separate board with complete fitting by 01 No of 6 A & 1 no of 16A switch & socket(modular type) ( with suitable size modular box & metallic cover plate (both side)including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge. (Make: legrand (Mylinc)/schneider (clipsal)/hager (Insysta))(For equipement power). (Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials. |
| 159 | Supplying,fixing of 2X 16A Plug on the separate board with complete fitting by 02 no of 16A switch & socket(modular type) ( with suitable size modular box & metallic cover plate (both side)including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge. (Make: legrand (Mylinc)/schneider (clipsal)/hager (Insysta))(For equipement power). (Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials. |
| 160 | Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 1.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor. In 20 mm dia non metallic heavy duty conduit (LDB to LSB/LIGHT CKT)(2X1.5+1X1.5) |
| 161 | Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.2 nos single core 2.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit.(BDB to LSB/LIGHT CKT/5A PLUG/UPS POINT ) (2X2.5+1X1.5) |
| 162 | Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.2 nos single core 4 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit .(PDB to PSB/ POWER POINT/AC POINT) (2X4+1X1.5) |
| 163 | Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.2 nos single core 6 sq. mm copper wire for phase and neutral and 01 no of single core 2.5 sq. mm copper wire for earth continuty conductor in 25 mm dia non metallic heavy duty conduit. (LFDB TO LBDB/UBDB) (2X6+1X2.5) |
| 164 | Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.4 nos single core 6 sq. mm copper wire for phase and neutral and 02 nos of single core 2.5 sq. mm copper wire for earth continuty conductor in 32 mm dia non metallic heavy duty conduit. (LFDB TO LBDB/Medical equipement) (4X6+2X2.5) |
| 165 | Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.4 nos single core 10 sq. mm copper wire for phase and neutral and 02 nos of single core 4 sq. mm copper wire for earth continuty conductorin 32 mm dia non metallic heavy duty conduit. (LFDB TO FLOOR PANEL TO TPN BDB power) (4X10+2X4) |
| 166 | Supply of 6 sq. mm 3 Core 1.1KV Grade ISI Marked pvc insulated pvc sheathed XLPE Alluminium Armored power Cable (Make-Polycab /Havells/Finolex) |
| 167 | Supply of 16 sq. mm 4 Core 1.1KV Grade ISI Marked pvc insulated pvc sheathed XLPE Alluminium Armored power Cable (Make-Polycab /Havells/Finolex) |
| 168 | Supply of 25mmsq. mm 3.5 Core 1.1KV Grade ISI Marked pvc insulated pvc sheathed XLPE Alluminium Armored power Cable (Make-Polycab /Havells/Finolex) |
| 169 | Laying of one number of PVC insulated and PVC sheathed / XLPE power cable of 1.1KV grade of size not exceeding 25 sq.mm as required. |
| 170 | Supply of cable tray 54x200 mm wire mesh cable tray of follwing specification: The tray should be hot dip galvanised with longitudinal T welded safety edge with internal dimension of size 54*200 mm . Load bearing capacity 121.77 kg/mtr each peice is of standard 3mtr long 54mm(H)X 200mm(W) Wire mesh Cable Trays in complete as per the direction of engineer charge. make: Legrand/Panduit/Siemon/OBO |
| 171 | Supply of cable tray 54x300 mm wire mesh cable tray of follwing specification: The tray should be hot dip galvanised with longitudinal T welded safety edge with internal dimension of size 54x300 mm . Load bearing capacity 149.36 kg/mtr 54mm(H)X 300mm(W) Wire mesh Cable Trays in complete as per the direction of engineer charge. make: Legrand/Panduit/Siemon/OBO |
| 172 | S/F of MS angle, Chanel with febrication & primer Colour in complete as per the direction of engineer charge. |
| 173 | S/F of 8 way SPN MCB DB on existgsurface / wall mounting with all connection complete in all respect as per direction of engineer incharge (Make : Schneider (ACTI 9 ) /legrand (Ekinox 3) /siemens (Betaguard)) |
| 174 | S/F of 12 way SPN MCB DB on existgsurface / wall mounting with all connection complete in all respect as per direction of engineer incharge (Make : Schneider (ACTI 9 ) /legrand (Ekinox 3) /siemens (Betaguard)) |
| 175 | S/F of 4 way TPN MCB DB on existgsurface / wall mounting with all connection complete in all respect as per direction of engineer incharge (Make : Schneider (ACTI 9 ) /legrand (Ekinox 3) /siemens (Betaguard)) |
| 176 | Supply and fixing of SP 6-32 A, 10 KA rating 240 V \\"C\\" series miniature circuit breaker suitable for lighting and other loads in the existing MCB DB ISI marked complete with connections testing and commissioning complete in all respect as per direction of Engineer in charge (Make : Schneider (ACTI 9 ) /legrand (DX 3)/siemens (Betaguard) /Hager) |
| 177 | Supply and fixing of DP 32A, 10 KA rating 415V \\"C\\" series miniature circuit breaker suitable for lighting and other loads in the existing MCB DB ISI marked complete with connections testing and commissioning complete in all respect as per direction of Engineer in charge (Make : Schneider (ACTI 9 ) /legrand (DX 3)/siemens (Betaguard) /Hager) |
| 178 | Supply and fixing of DP 63A, 10 KA rating 415V \\"C\\" series miniature circuit breaker suitable for lighting and other loads in the existing MCB DB ISI marked complete with connections testing and commissioning complete in all respect as per direction of Engineer in charge (Make : Schneider (ACTI 9 ) /legrand (DX 3)/siemens (Betaguard) /Hager) |
| 179 | Supply and fixing of FP 32A, 10 KA rating 415V \\"C\\" series miniature circuit breaker suitable for lighting and other loads in the existing MCB DB ISI marked complete with connections testing and commissioning complete in all respect as per direction of Engineer in charge (Make : Schneider (ACTI 9 ) /legrand (DX 3)/siemens (Betaguard) /Hager ) |
| 180 | Supply and fixing of FP 63A, 10 KA rating 415V \\"C\\" series miniature circuit breaker suitable for lighting and other loads in the existing MCB DB ISI marked complete with connections testing and commissioning complete in all respect as per direction of Engineer in charge (Make : Schneider (ACTI 9 ) /legrand (DX 3)/siemens (Betaguard) /Hager ) |
| 181 | S/F of 09 inch Heavy duty (Metalic Colour) Exahust Fan with wall cutting, S/F of proper size of hume pipe, concreating, plastaring, painting with all connection testing and commissioning complete in all respect as per direction of Engineer in charge (Make:- Almonard / Usha- S. PH Turbo/Crompton - Trans Air/Khaitan,/ Havells) |
| 182 | S/F of 400 MM Wall Mounted fan all connection testing and commissioning complete in all respect as per direction of Engineer in charge (Make:- Almonard / Usha/Crompton /Khaitan,/ Havells) |
| 183 | Supplying, installation, testing and commssioning of 1200 mm sweep white/milky colour BLDC ceiling fan with aluminium blades having wattage not more than 28W and air delivery 215m3/min Make-Crompton Energion Groove /Havells Efficiencia Neo/Usha Technix ) including wiring the down rod of standard length (upto 30 cm) with 1.5 sq mm PVC insulated, copper conductor, single core cable etc. as required as per direction of Engg.in Charge,Replacement Warranty will be 4 years.. |
| 184 | S/F of step type 2 Modular electronic Fan Regulator ISI Marked with all connection complete in all respect as per direction of Engineer in charge (Make: legrand (Mylinc)/schneider (clipsal)/hager (Insysta)) |
| 185 | S/F of Call Bell / Ding dong Bell ISI marked on 6''x4'' confirming to IS-2268/1994 and bell push of ISI marked confirming to IS-1293/1988 (Make: Cona/Anchor) |
| 186 | S/F of A.C. point consisting of 32 amp industrial male female socket &top with 20-32 amp single phase starter with all connection complete in all respect as per direction of engineer incharge (Make: legrand (Mylinc)/schneider (clipsal)/hager (Insysta)) |
| 187 | Supply and fixing of 10watt,CW/WW 5700K,1800 Lumen led Aluminium Housing batten on wall ,making connections, etc. as required complete in all respect as per direction of Engineer in charge (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj) (2Years Warranty) |
| 188 | Supply and fixing of 20watt,CW/WW 5700K,1800 Lumen led Aluminium Housing batten on wall ,making connections, etc. as required complete in all respect as per direction of Engineer in charge (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj) (2Years Warranty) |
| 189 | Supply and fixing of 18 watt Surface Light ,making connections, etc. as required complete in all respect as per direction of Engineer in charge (Make : Panasonic/ Great white/ Orient/ wipro/ Havells/Phillips)(2Years Warranty) |
| 190 | Supply and fixing of 18 watt Recess Light ,making connections, etc. as required complete in all respect as per direction of Engineer in charge (Make : Panasonic/ Great white/ Orient/ wipro/ Havells/Phillips)(2Years Warranty) |
| 191 | Supply and fixing of 34 watt Recess Light ,making connections, etc. as required complete in all respect as per direction of Engineer in charge (Make : Panasonic/ Great white/ Orient/ wipro/ Havells/Phillips)(2Years Warranty) |
| 192 | S/F of Street light-ENDURA 60 W CITYLINER NEO new generation energy saving & environmental friendly long life versatile pressure die-cast alluminium IP66 roadway luminaire with high power LED as light source with acrylic cover.(Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj) (2Years Warranty) |
| 193 | Fixing of Street light with G.I bracket and pipe |
| 194 | Supply,installation, testing and commissioning of Air Cooled HI Wall split type Air conditioners complete with Indoor unit (IDU), Out door unit (ODU), i/c R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low & high voltage cut off and50 hz ,1 phase AC Supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll /rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 Degree Celsius. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS694 or IS 9968 temperature sensing control IS/ International Electro technical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per IS :1391 Part II 2023. The system shall be able to operate up to 50 Degree C (out door ambient temperature). The indoor outdoor must be Blue Fin coated. The unit price included with 3mtr Copper piping with insulation, drain Pipe and copper Power cable. The indoor should have 4 way swing . 5 Star Inverter Type - Cooling only 2.0 TR with 5 Star BEE Rating (O General-ASGG24CGWA-B/ Daikin-FTKM60XV16) |
| 195 | S/F of copper cooling pipe with insulation packing and flexible copper cable |
| 196 | S/F of Nylon Netted Drain Pipe with C clamp |
| 197 | S/F. Of Powder coated Wall Stand with Anchor Fastener (For 1.5 Ton/ 2 Ton ) |
| 198 | S/F 5 kva voltage stabiliser 130-300V (make : V guard) |
| 199 | S/F of Earthing with medium class 40mm 3Mtr. Long ISI marked GI Earth pipe including accessories such as funnel GI nut, Bolt, washer , hinged cover plate with looking arrangement, 40mm to 20GI rediusor 5nos 20mm dia holes on GI pipe required charpol salt, Excavation of earth brick work in cement mortar complete in all respect as per specification of SR 2011 and as per Direction of Engineer-in -Chage |
| 200 | Supply and fixing copper plate earthing 600 mm X 600 mm X 3.15 mm thick ISI marked including accessories and providing masonary with charcoal and salt with all connection complete in all respect as per direction of engineer incharge |
| 201 | Providing and fixing 25mm x 5 mm copper strip on surface or in recess for loop earthing along with existing surface / recessed conduit with all connection complete in all respect as per direction of engineer incharge |
| 202 | Supplying and laying 6 SWG G.I wire on surface or in recess for connection etc as required. |
| 203 | S/F of 63 - 100 A copper busbar panel of size 18*12*8 inch of 63 AMP 2 Pole MCCB AS INCOMER copper busbar, 240V 2 strip & internal connection & provision for termination of incomming & out going cable , earthing, Indicator. (For UPS) |
| 204 | S/F of 63 - 100 A copper busbar panel of size 28*16*8 inch of 63 AMP 4 Pole MCCB AS INCOMER copper busbar, 415V 4 strip & internal connection & provision for termination of incomming & out going cable , earthing, Indicator. ( For Power Load) |
| 205 | S/F of 63 - 100 A copper busbar panel of size 28*16*8 inch of 63 AMP 4 Pole MCB AS INCOMER copper busbar, 415V 4 strip & internal connection & provision for termination of incomming & out going cable , earthing, Indicator. (For EI Load) |
| 206 | S/F of 200 A cubical panel board made of 16 SWG C.R sheet with powder coated with provision of following items with fabrication erection testing & comissioning of total enclosed panel board of size not less than 72\\"x40\\"x12\\" with copper double busbar of 200A, 415V 4strip & internal connection & provision for termination of incomming & out going cable , earthing etc, complete with supply & fixing of following switch gears. RYB Indicator, 1. 200A 25ka 4p Mccb -1no, 2. 100A 25ka 4p Mccb -1no, 3. 200 A C/o-1No, 4.63A 16 KA MCCB-2 Nos, 5. 100A 16 KA MCCB-1 No, 6. 63 Amp DP MCB-2 Nos, 7. 63 Amp FP MCB-1 Nos, 8. SPD separete busbar for both dg and main ,earthing connector, Cable alley. |
| 207 | Supply and fixing of 4 pole (3P+N) ( T1+T2 - Iimp 8 kA/pole T2 - 60 kA) 40 KA SPD in existing cubicle panel board including drilling holes in cubcle panel, making connections, etc. as required complete in all respect as per direction of Engineer in charge (Make : Schneider (ACTI 9 ) /legrand (DX 3)/siemens (Betaguard) /Hager) |
| 208 | Supply and fixing of 4 pole MCCB 200A,Ics = 100% Icu, 25 KA breaking capacity, adjustableThermal,fixed magnetic type in existing cubicle panel board including drilling holes in cubcle panel, making connections, etc. as required complete in all respect as per direction of Engineer in charge (Make : Schneider (ACTI 9 ) /legrand (DX 3)/siemens (Betaguard) /Hager) |
| 209 | Supply and fixing of 4 pole MCCB 16-100A,Ics = 100% Icu, 16 KA breaking capacity, adjustableThermal,fixed magnetic type in existing cubicle panel board including drilling holes in cubcle panel, making connections, etc. as required complete in all respect as per direction of Engineer in charge (Make : Schneider (ACTI 9 ) /legrand (DX 3)/siemens (Betaguard) /Hager) |
| 210 | Supply and fixing of 4 pole MCCB 100A,Ics = 100% Icu, 25 KA breaking capacity, adjustableThermal,fixed magnetic type in existing cubicle panel board including drilling holes in cubcle panel, making connections, etc. as required complete in all respect as per direction of Engineer in charge (Make : Schneider (ACTI 9 ) /legrand (DX 3)/siemens (Betaguard) /Hager) |
| 211 | Supply and fixing of Digital Meter Displays Current, line to neutral & line to line Voltages, frequency & Power Factor. (VA & PF - Phase Wise & Average) IEC 62053-21 complete with connections testing and commissioning complete in all respect as per direction of Engineer in charge (Make : Schneider (ACTI 9 ) /legrand (DX 3)/siemens (Betaguard) /Hager) |
| 212 | Supply and fixing of 4 pole 200 AMP changeover in existing cubicle panel board including drilling holes in cubcle panel, making connections, etc. as required complete in all respect as per direction of Engineer in charge (Make : Havells/ C&S /L&K ) |
| 213 | Supply and fixing of DP 32A, 10 KA rating 415V \\"C\\" series miniature circuit breaker suitable for lighting and other loads in the existing MCB DB ISI marked complete with connections testing and commissioning complete in all respect as per direction of Engineer in charge (Make : Schneider (ACTI 9 ) /legrand (DX 3)/siemens (Betaguard) /Hager) |
| 214 | Supply and fixing of DP 63A, 10 KA rating 415V \\"C\\" series miniature circuit breaker suitable for lighting and other loads in the existing MCB DB ISI marked complete with connections testing and commissioning complete in all respect as per direction of Engineer in charge (Make : Schneider (ACTI 9 ) /legrand (DX 3)/siemens (Betaguard) /Hager) |
| 215 | Supply and fixing of FP 63A, 10 KA rating 415V \\"C\\" series miniature circuit breaker suitable for lighting and other loads in the existing MCB DB ISI marked complete with connections testing and commissioning complete in all respect as per direction of Engineer in charge (Make : Schneider (ACTI 9 ) /legrand (DX 3)/siemens (Betaguard) /Hager ) |
| 216 | FIRE EXTINGUISHERS :Providing & fixing ABC type (Dry powder type ) extinguishers. Including all accessories as per IS specification (IS :15683) Consisting of welded MS cylindrical body with discharge hose ,discharge valve ,suspension brackets,initial filling etc. complete as required., initial filling etc complete as required. Capacity - 6 kg . Make : Fireshiled/ Kanex/ Safex/ ceasefire |
| 217 | Providing & fixing Water based Carbon-di-oxide 4.5 ltrs. fire extinguishers as per IS specification consisting of welded MS cylindrical body ,squeeze lever discharge valve fitted with internal discharge tube ,30 cm long high pressure discharge hose ,discharge nozzle,suspension brackets,finished exteranally with red enemel paint and fixed to wall with brackets with rawl plug/dash fastners complete with initial charging. Make : Fireshield/Kanex/ Safex/ ceasefire |
| 218 | CCTV:- Suppy and installation of 5 megapixel Ai base Dome camera with video resolution of 2592*1944 pixels, support video compression H.26+/H.265(HEVC)/H.264+/H.264/MJPEG, built-in intelligent analytics-region Entran, Region Exiting, Advance Motion Detection, Tamper Detection, Line Crossing, Loitering, Object left, Object removed. People counting-Count the number of people entering or exiting, up to 4 detection areas for regional people counting. Built-in Microphone. IP67 and IK10 compliant 120dB super WDR, IR Distance of upto 50mtr. (Make: Honeywell Impact, Axis, Plco) |
| 219 | Suppy and installation of 5 megapixel Ai base Bullet camera with video resolution of 2592*1944 pixels, support video compression H.265+/H.265(HEVC)/H.264+/H.264/MJPEG, built-in intelligent analytics-region Entran, Region Exiting, Advance Motion Detection, Tamper Detection, Line Crossing, Loitering, Object left, Object removed. People counting-Count the number of people entering or exiting, up to 4 detection areas for regional people counting. Built-in Microphone. IP67 and IK10 compliant 120dB super WDR, IR Distance of upto 50mtr. (Make: Honeywell Impact, Axis, Plco) |
| 220 | Supply and Installation of 32Chanel 4K UHD NVR with 8SATA*8TB storage capacity, Decode up to 4-CH 4K UHD & 16-CH 1080P, ANR/RAID/N+1 Hot Spare, Dual Lan interface(for Multi addressing, Load balancing and Net Fault-tolerance) and Multi-video output.(Make: Honeywell Impact, Axis, Plco) |
| 221 | Supply and installation of 24 Port Gigabite L2+ Managed PoE switch with 4 SFP Ports. 8/16/24 Gigabit Ethernet ports and 2/4 Gigabit SFP ports Smart power control to support dynamic PoE/PoE+ power allocation per port for the PoE models, Provides quaternary binding of IP, MAC, VLAN & port; ARP Inspection, IP Source Guard, DoS protection, port security & DHCP snoopingLocal Web UI to manage switch; on-premise Wi-Fi management platform. (Make: HP/CISCO/DIGISOL) |
| 222 | Supply and installation of 8 Port Gigabite L2+ Managed PoE switch with 4 SFP Ports. 8/16/24 Gigabit Ethernet ports and 2/4 Gigabit SFP ports Smart power control to support dynamic PoE/PoE+ power allocation per port for the PoE models, Provides quaternary binding of IP, MAC, VLAN & port; ARP Inspection, IP Source Guard, DoS protection, port security & DHCP snoopingLocal Web UI to manage switch; on-premise Wi-Fi management platform. (Make: HP/CISCO/DIGISOL) |
| 223 | Supply and installation of Multi Wan Gigabit Router. Powered by Wi-Fi 6 (802.11ax) standard with up to 1.77Gbps wireless throughput, Dual-band 2x2:2 MU-MIMO with DL/UL OFDMA technology, Built-in VPN support allows easy access to corporate networks for remote employees Supports 256 concurrent Wi-Fi client devices, Supports Mesh networking with access points to provide easy network expansion, Powerful security features include guest network, network blacklist, Antihacking secure boot & critical data/control lockdown via digital signatures, and more Rich firewall features including Anti-DoS, traffic rules, NAT and ALG, Secure cloud provisioning through GWN.Cloud (Make: Netgear/Honeywell/CISCO/Digisol) |
| 224 | Supply and Installation of 43\\" UHD IPS Commercial Digital Display: Brightness (330 nits or higher), Dynamic Contrast Ratio (Dynamic MCI (Hz)):1000000:1), 1000000:1, Static (Panel) Contrast Ratio-1200:1, Response Time (G to G)-8 ms, Refresh Rate.-60 Hz, Life span (hrs)-30,000, Speaker (Sound Output):10W + 10W, Speaker System: 2.0 ch, DVB-T2/C Broadcasting System, Commercial Smart UX, webOS version (webOS 6.0), BIS Certification with 3 years onsite warrenty.. Make: Samsung/ LG /SONY |
| 225 | Supply & Installation 8 TB Surveillence Hardisk. complete in all respect as per direction of Engineer in charge (Make: Seagate/WD) |
| 226 | Supply and Laying Cat6 23agw 4 pair UTP Cable. Make: Digisol/Legrand |
| 227 | Supply & laying of 25 Sqmm PVC Pipe conduit on wall Complete in all respect as per the direction of engineer in charge Make:-AKG/Pricision |
| 228 | Supply and Installation of Cat6 24 Port Patch Panel loaded with 10nos Keystone jack. Make: Digisol/Legrand |
| 229 | Supply and fixing of 6U/500D Wall Mount Rack with 1XFAN, 1X 6skt 6/16amp PDU and H/W Screw Pk. Make: Legrand/Valrack/Netrack |
| 230 | Supply and fixing of 9U/500D Wall Mount Rack with 1XFAN, 1X 6skt 6/16amp PDU and H/W Screw Pk. Make: Legrand/Valrack/Netrack |
| 231 | Supply and Fixing of Single Mode SC-LC, Dplx OFC Patch Cord, 2mtr. Make: Digisol/Legrand |
| 232 | Supply and Installation of Cat6 I/O With Single Face Plate. Make: Tyco-AMP/ Legrand/ Digisol. |
| 233 | Supply and Installation of Cat6 I/O With Dual Face Plate. Make: Tyco-AMP/ Legrand/ Digisol. |
| 234 | Supply and Installation of 2M PVC Box. Make: Tyco-AMP/ Legrand/ Digisol. |
| 235 | Supply & Installation of Cat6 Factory crimpped moulded 0.5mtr patch cord. Make: Tyco-AMP/ Legrand/ Digisol. |
| 236 | Installation and Commisioning cost of Camera and NVR including accessories as require |
| 237 | P.H. WORKSupplying all materials, labour, T&P and providing and fixing to wall or ceiling and floor CPVC pipes conforming to IS:15778 having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings including fixing the pipe with clamps at 1.00. spacing. This includes Jointing of pipes & fittings with one step CPVC solvent cement and testing of Joints all complete as per specification and direction of the Engineer in charge.20mm dia CPVC pipe 20mm dia C- PVC pipe In ground floor |
| 238 | In First floor |
| 239 | In 2nd floor |
| 240 | 25mm dia C-PVC pipe ground floor |
| 241 | In first floor |
| 242 | In 2nd floor |
| 243 | 32mm dia C-PVC Pipe in ground floor |
| 244 | In first floor |
| 245 | In 2nd floor |
| 246 | Supplying all materials, labour, T&P and providing and fixing to wall or ceiling and floor pvc pipes conforming to ASTM-D-1785/89 (Sch-80) and pipe fittings of the following nominal bore with clamps including making good the wall, ceiling and floor all complete as per specification and direction of the Engineer in charge.25mm dia PVC ASTM pipe (sch-80) Ground floor |
| 247 | Ist floor 25mm dia PVC ASTM pipe (sch-80) |
| 248 | In 2nd floor |
| 249 | 32mm dia PVC ASTM pipe (sch-80) Ground floor |
| 250 | In first floor |
| 251 | In 2nd floor |
| 252 | In third floor over roof |
| 253 | 40mm dia PVC ASTM pipe In G.F |
| 254 | In first floor |
| 255 | In 2nd floor |
| 256 | In 3rd floor over roof |
| 257 | 50 mm dia PVC ASTM pipe (sch-80) 3rd floor over roof |
| 258 | Supplying all materials, labour, T&P and cutting holes through existing brick work including making good the damages in cement mortar (1:4) for taking GI pipes and fittings/ PVC pipes and fittings etc all complete as per PH specification and direction of the Engineer in charge.250mm thick wall |
| 259 | First floor |
| 260 | 2nd floor |
| 261 | Supplying all materials, labour, T&P and cutting hole in R.C.C floors, roofs, etc upto 19 cm thick for passing GI pipes / PVC pipes and fittings etc and repairing the holes after insertion of pipes etc with cement concrete (1:2:4) including finishing complete so as to make it leak proof as per direction of the Engineer in charge.In ground floor |
| 262 | Supplying all materials, labour, T&P and cutting grooves in pucca floors and walls for taking GI/ PVC pipes and making good the damages as per the direction of the Engineer in charge.In ground floor |
| 263 | First floor |
| 264 | 2nd floor |
| 265 | Supplying all materials, labour, T&P and fitting and fixing brass/CP fittings of the following nominal bore with supply of all jointing materials complete as per specification and direction of the Engineer in charge. 15mm dia CP bib cock CON-CHR-037KN(Jaquar make ) |
| 266 | 15 mm dia CP two way Bib cock CON-CHR-041KN(Jaquar make ) |
| 267 | 15mm dia CP Health foucet (Con-ALD-CHC-573 Jaquar make) |
| 268 | 15 mm dia CP Long body Bib cock( CON-CHR-107KN Jaquar make ) |
| 269 | 15mm dia CP angle stop cock(CON-CHR-053KN Jaquar ) Make |
| 270 | 20mm dia CP concealed stop cock(CON-CHR-069KN Jaquar ) Make |
| 271 | 15mm dia C.P. bottle trap ALD-CHR-769L300X190 Jaquar make |
| 272 | 15mm dia PILLAR COCK WITH FLOW RESTRICTOR OF 6.0ARI-CHR-39011GA Jaquar make |
| 273 | 25mm dia CPVC full way valve |
| 274 | 32mm dia CPVC full way valve |
| 275 | 40mm dia CPVC full way Valve |
| 276 | 50mm dia CPVC full way Valve |
| 277 | 15mm dia CP flange |
| 278 | 15mm dia CP extension piece |
| 279 | Supplying all materials, labour, T&P and fitting and fixing CP shower with 15mm or 20mm inlet with CP shower arm including polishing all complete as per specification and direction of the Engineer in charge.15mm dia CP revolving shower ( Plaza make ) |
| 280 | Supplying all materials, labour, T&P and fitting and fixing 10 litres capacity low level flushing cistern with a pair of cast iron or M.S brackets complete with fittings such as siphonic arrangements 15mm nominal size brass/pvc ball valve with polythene float CP brass handle, unions and couplings for connection with inlet, outlet and overflow pipes,32mm dia CP flush bend,15mm dia pvc inlet connection pipe including cutting holes and making good the same and connecting the flush bend with cistern and closet and connecting the inlet pipe with supply main etc all complete as per specification and direction of the Engineer in charge 10 litres capacity pvc low level cistern with 32mm dia CP long flush bend Slimline white |
| 281 | Supplying all materials,labour,T&P and fixing Rotational moulded polyethylene cylindrical vertical water storage tanks conforming to IS : 12701--1996 including cutting holes through the tank and fixing mild steel tubes and fittings and providing extra sockets and jam nuts, fixing ball valve etc, including hoisting upto a height of 5 metres above ground level and placing the tank to the required position and providing 1st class K.B brickwork in cement mortar (1:6) of 0.46m height in staging and in circular protection wall to support the tank, 12mm thick cement plaster (1:6) over brickwork, R.C.C slab of size 1.60mx1.60m and 0.10m thick, R.C.C beam of 0.25mx0.30m and 2.60m average length in cement concrete(1:2:4) using 12mm size h.g chips including centering and shuttering, watering, curing, conveyance of all materials to worksite etc all complete as per specification and direction of the Engineer in charge.On the roof of 2nd floor 2000litre capacity water storage tanks |
| 282 | Supplying all materials, labour, T&P and providing, fitting and fixing submersible pump with squirrel cage induction type submersible type submersible electric motor to run on 3 phase/1 phase line voltage ranging from 320 volt to 450 volt conforming to IS: 8034/89 with following specifications with suitable control panel, jointing with GI/PVC/HDPE pipes, electrification, testing, commissioning, trial running, conveyance of all materials to worksite, payment of taxes etc all complete as per specification and direction of the Engineer in charge 1 H.P three phase 3 stage head range 30 to 54 metres, discharge 155 to 110 L.M.P with outlet dia of 32mm OPEN well submersible pump(Kirloskar make) |
| 283 | DOL Control panel |
| 284 | 2.50sqmm flat cable |
| 285 | 20mm dia rigid UPVC pipes |
| 286 | Labour charges for lowering including transportation |
| 287 | Supplying all materials, labour, T&P and fitting and fixing U PVC SWR soil waste ventilating pipes and fittings of the following outside diameter conforming to ISI No. 13592 1992 to walls with nails, bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricant by non heat application method/as per manufacturer s specification, testing, earthwork in excavation in all kinds of soil and refilling of trenches as per specification and direction of the Engineer in charge In ground floor110mm dia UPVC SWR pipe(Ashirbad / Supreeme ) |
| 288 | 110mm U-PVC door cross tee |
| 289 | 110mm U-PVC door tee |
| 290 | 110mm U-PVC door bend |
| 291 | 110mm U-PVC plain bend |
| 292 | 110mm U-PVC Plain tee |
| 293 | 110mm dia U-PVC 'P' trap |
| 294 | 110mm dia U-PVC Plain Shoe Bend |
| 295 | 110mm dia U-PVC offset with out ear |
| 296 | 110mm dia U-PVC cowl |
| 297 | 125mm dia CP grating |
| 298 | 110mm dia UPV Clamp/ Clip |
| 299 | 110mm dia UPVC Socket |
| 300 | Supplying all materials, labour, T&P and cutting holes through existing brick or laterite masonry wall for taking HCI pipes and fittings including making good the damages etc all complete as per PH specification and direction of the Engineer in charge 250mm to 375mm thick wall |
| 301 | Supplying all materials, labour, T&P and cutting of R.C.C roof or cornice for taking H.C.I pipes and making good the damages etc all complete as per P.H.Specification and direction of the Engineer in charge. |
| 302 | Supplying all materials, labour, T&P and fixing vitreous china water closet, squatting pan (Indian type W.C pan/Orissa pattern squatting pan) duly embedded in cement concrete (1:5:10) using 4cm size hard granite metal including fixing a pair of vitreous china 250mm x 130mm x 30mm footrest, fixing 100mm dia HCI P or S trap (with/without 50mm dia horn) for water closet squatting pan including jointing the trap with pan in cement mortar (1:1) cutting the floor and mending good the damages etc all complete as per specification and direction of the Engineer in charge 580mm size Orissa pan (Parryware / Nycer make ) |
| 303 | Supplying all materials, labour, T&P and fixing the following vitreous china Wash Down Water Closet (European type W.C pan) with integra lP or S trap to the floor with wooden plug and chromium plated pedestal screws including jointing the trap with soil pipe in cement mortar (1:1), fixing plastic seat and cover for wash down water closet with chromium plated brass hinges and rubber buffers including polishing etc all complete as per specification and direction of the Engineer in charge. European water closet with S trap plain (Parryware / Nycer make ) |
| 304 | JAQUAR/HINDWARE/CERA/PARRYWARE. SLS-WHT-6851S300UFSingle Piece-WC with UF soft closeseat cover, Hinges, Fixing Accessories,A ccessories Set and Cistern fittings,Size: 360x725x735 mm, S Trap-300 mm |
| 305 | Providing all materials, labour, T&P for fitting and fixing of white glazed vitreous china water closet (European pattern) 'P' or 'S' type with cistern & seat cover, wash hand basin of size 650mmx350mm with one pair basin bolt, one no. hinged rail 760mm long & 5 nos. grab rails 600mm long including supply of sutaible PVC wall plug and Brass screws etc. suitable for handicapped toilets in all floor etc. all complete including cost, taxes and conveyance as per specification all complete as per direction of Engineer-in-charge. Make:HINDWARE/CERA. (As per Model-Matrix Set of Hindware) Matrix set of Hindware |
| 306 | Supplying all materials, labour, T&P and fixing bowl pattern urinal conforming to IS:771-part-3-1985 of the following sizes including connecting the urinal with 32mm dia pvc waste pipe 910mm long by means of white lead mixed with chopped hemp, fixing 32mm dia CP dome waste, 15mm dia CP spreader including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc all complete as per specification and direction of the Engineer in charge. Stall urinal (Parryware / Hindware make ) |
| 307 | 15mm dia urinal spreader |
| 308 | 32mm dia C.P. dome waste |
| 309 | Supplying all materials, labour, T&P and fixing glazed earthenware squatting plate of size 600mmx350mm with integral longitudinal flushing pipe including embedding the plate in 25mm cement mortar (1:8) laid over 150mm cement concrete (1:5:10) using 40mm hard granite metal all complete as per specification and direction of the Engineer in charge.Squatting urinal of size 600mmx350mm (Parryware/ Neycer/ Hindware) |
| 310 | Supplying all materials, labour, T&P and fixing wash basins with hole for pillar taps with cast iron or M S brackets painted white including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc, fixing pedestal for wash basin recessed at the back for the reception of pipes and fittings, fixing PVC waste pipe of 32mm nominal diameter for wash basin including brass check nut complete, fixing pillar taps capstan head screw down high pressure lettered Hot and Cold with long screws, shanks and back nuts of 15mm dia nominal bore, fixing 15mm dia PVC inlet connection pipe and making connection with pillar cocks and supply mains for wash basin, fixing 32mm dia CP brass waste, etc all complete as per specification and direction of the Engineer in charge. (a)W.H.Basin( Counter top basin 560x455 (Parryware make) white) (Excluding pillar cock) |
| 311 | 550mmx400mm size wash hand basin with porcelain pedestal Parryware/ Hind ware /Neyser make ) |
| 312 | Supplying all materials, labour, T&P and fixing mirror of superior glass mounted minimum 5mm thickon 6mm thick A.C sheet or plywood sheet and fixed to wooden plugs with CP screws and washers complete as per specification an direction of the Engineer in charge . 600mmx450mm size B.E mirror x minimum 5mm thick(Alpina make ) |
| 313 | Supplying all materials, labour, T&P and fixing standard sized glass-shelf with CP brass brackets and guard rails complete fixed to wooden plugs with CP screws as per specification and direction of the Engineer in charge Acrylic glass shelf with CP guard rails |
| 314 | Supplying all materials, labour, T&P and fixing standard sized CP towel rail complete with CP brass brackets fixed to wooden plugs with CP screws as per specification and direction of the Engineer in charge 25mmx600mm long CP towel rail |
| 315 | C.P. Ring Towel Rail |
| 316 | Supplying all materials, labour, T&P and fixing CP soap holder complete with CP brass brackets fixed to wooden plugs with CP screws as per specification and direction of the Engineer in charge CP soap holder |
| 317 | Supplying all materials labour T&P and filling in foundation and plinth with sandwell watered and rammed including conveyance of all materials to work sitepayment of royalty taxes etc all complete as per direction of Engineer in charge In ground floor |
| 318 | Supplying all materials, labour, T&P and providing cement concrete (1:4:8) with 4cm size hard granite metal including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge. In ground floor |
| 319 | Supplying all materials, labour, T&P and providing cement concrete (1:2:4) with 12mm size hard broken granite chips including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge. In ground floor |
| 320 | In Ist floor |
| 321 | In 2nd floor |
| 322 | Supplying all materials, labour, T&P and providing 12mm thick cement plaster (1:4) on brickwork including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge In ground floor |
| 323 | In Ist floor |
| 324 | In 2nd floor |
| 325 | Supplying all materials, labour, T&P and providing 12mm thick cement plaster (1:4) on brickwork with cement punning for skirting including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge In Ist floor |
| 326 | In 2nd floor |
| 327 | Supplying all materials, labour, T&P and filling in sunken floor in toilets with cinter (light weight slag) well watered and rammed include conveyance of all materials to worksite payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge. In First floor |
| 328 | In 2nd floor |
| 329 | Supply of all materials & laying the waterproofing material of Dr.Fixit torch shield P3160(3mm)with its primer 2 coats or equivalent water proofing material after drying cleaning the concrete surface over the concrete floor/roof/ balcony/sunken and dado upto 1\\"6\\" in wall including cleaning,applying and mending as per specification including cost, conveyance, taxes, royalities of all materials to work site etc.all complete as per the direction of the Engineer-in-charge. In First floor |
| 330 | In 2nd floor |
| 331 | Supplying all materials, labour, T&P and providing brick work with Fly Ash bricks having crushing strength not less than 75kg/cm² with dimensional tolerance ± 8 percent in cement mortar (1:4) including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge In ground floor |
| 332 | In first floor |
| 333 | In 2nd floor |
| 334 | Supplying all materials, labour, T&P and providing ceramic tiles in floors, treads and landing on 25mm thick bed of cement mortar 1:1 (1 cement:1 sand) joined with neat cement slurry mixed with pigment to match the shades of the tiles including rubbing and polishing complete as per direction of the Engineer in charge. 60 cm. x 60 cm. Kajaria / Somany / Johnson to be pree approved .In ground floor |
| 335 | In Ist floor |
| 336 | In 2nd floor |
| 337 | Supplying all materials, labour, T&P and fixing porcelain glazed tiles in dados skirting on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigments to match the shades of the tiles including rubbing and polishing complete as per direction of the Engineer in charge.60cm. x 30cm. Kajaria / Somany / Johnson to be pree approved .In ground floor In ground floor |
| 338 | In Ist floor |
| 339 | In 2nd floor |
| 340 | Supplying all materials, labour, T&P and fixing granite tiles in dados skirting on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigments to match the shades of the tiles including rubbing and polishing complete as per direction of the Engineer in charge in ground floor |
| 341 | In First floor |
| 342 | In 2nd floor |
| 343 | Supplying all materials, labour, T&P and providing rigid and smooth centering and shuttering for R.C.C works including false work and dismantling them after casting including conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge R.C.C floor and roof slabs up to 4.30m heightIn ground floor |
| 344 | In first floor |
| 345 | In 2nd floor |
| 346 | Supplying all materials, labour, T&P and providing M.S reinforcement for R.C.C work including cutting, bending, binding, and tying the grills and placing in position including cost of binding wire 18 to 20 gauge, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge .In ground floor |
| 347 | In first floor |
| 348 | In 2nd floor |
| 349 | Supplying all materials, labour,T&P and providing cement concrete(1:1 ½:3) with 12mm size hard broken granite chips for R.C.C works including hoisting, laying, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge In ground floor |
| 350 | In first floor |
| 351 | In 2nd floor |
| 352 | Factory made single leaf rigid FRP(alternately called GRP) sandwich composite door shutter of 32mm thick laminated with two GRP skins with wood grain finish fabricated using UV-stabilised Isopthalic Gelcoat and one layer of 450 gsm E-glass Chopped Strand Mat (CSM) impregnated with orthopthalic palyester resin. The thickness of the skins shall not be less than 3.00mm Expanded Polystyrone(EPS) structural foam panel of 29mm thickness and a density of 20kg/cu.mtr shall be used as core material. Wooden reinforcements made of seasoned sal wood block of cross section not less than 28mmx32mm and also necessary sal wood reinforcements for fitting the metal fittings such as tower bolts, aldrops, handles etc shall be provided. A structural adhesive compatible with (EPS) foam shall be used for bending the core material, the sal wood reiforcements and the skins. The material and process for manufacturing the door shutters shall conform to RV-TIFAC composites Design Centre's standards and specifications and the door shutters tested in conformation to IS: 4020-1998. The finish of door shutter will be plain colour white/ Ivory/ Beige/ Light grey/ Mahogany/ Teak wood or any other colour using high quality pigments. Three heavy whight mild steel butt hinges type-I(ISI marked) size 100mm are to be fitted on one side of shutter with FRP frame of size 45x90mm.(Darwaja /Exon Door make) |
| 353 | Supplying all materials, labour, T&P and providing fitting and fixing (Aqua guard) Pure Chill 120 PSS RO+UV of size 750x570x1350mm height with water storage capacity 80 liters along with 2 nos of faucets 1 for cold water and 1 for normal water including a flow of 1.5 ltr per minute etc all complete as per approved drawing,specification and direction of the Engineer in charge. Aquaguard 120 PSS RO+UV |
| 354 | EXTERNAL P.H. WORK Supplying all materials, labour, T&P and laying in trenches (to level or slope) unplasticized PVC pipes conforming to IS: 4985/2000 of the following outside dia for class 3(0.60mpa) including jointing with supply of approved solvent cement by non-heat application method/as per manufacturers specification, providing and laying in trench cement concrete (1:4:8) with 40mm size hard granite metal in the Type C 1 standard bedding surrounding or encasing including concrete for bedding and curing etc all complete as per PH specification and direction of the Engineer in charge.110mm dia |
| 355 | 160mm dia |
| 356 | Supplying all materials, labour, T&P and constructing gully trap chamber of the following inside size with 8cm thick R.C.C precast cover slab in cement concrete (1:2:4) mix using 12mm size h.g chips, foundation concrete (1:4:8) using 40mm size hard granite metal on bed and around trap, KB brickwork in cement mortar (1:6) in F&P and inside 12mm thick cement plastering (1:3) finished with a floating coat of neat cement including fixing 100mmx100mm size HCI gully trap,150mmx150mm size CI grating etc all complete as per approved drawing, specification and direction of the Engineer in charge.Inside size 250mmx250mm |
| 357 | Supplying all materials, labour, T&P and constructing inspection chamber of the following size with cement concrete(1:3:6) using 40mm size hard granite metal on bed, 1st class fly ash brickwork in cement mortar(1:6), moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size h.g chips, 12mmthick cement plaster (1:3) with punning to inside, cement flush pointing (1:3) to outside, RCC cover slab in (1:1.5:3) using 12mm size h.g chips with RCPC man hole cover, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge. Inside size 760mmx760mmx460mm |
| 358 | ---- do --- addl depth of 0.15m upto 0.90m |
| 359 | R.C.P.C.Manhole Cover |
| 360 | Supplying all materials, labour, T&P and constructing man hole chamber of the following size with cement concrete(1:3:6) using 40mm size hard granite metal on bed, fly ash brickwork in cement mortar(1:6), moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size h.g chips,12mmthick cement plaster (1:3) with punning to inside, cement flush pointing (1:3) to outside, R.C.C cover slab in (1:1.5:3) using 12mm size h.g chips with RCPC man hole cover, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge. Inside size 910mmx910mmx910mm |
| 361 | R.C.P.C.Manhole Cover |
| 362 | Supplying all materials, labour, T&P and constructing soakway pit of the following size with dry brick walling from bottom upto invert of inlet pipe and fly ash brickwork in cement mortar (1:6) for the remaining height at top, cement concrete (1:4:8) using 40mm size hg chips on bed, 12mm thick cement plaster (1:4) inside and outside over masonry brickwork, gravel backing in the rear of well steining, RCC cover slab in cement concrete (1:2:4) using 12mm size hg chips fitted with iron lifting handles including earthwork in open well excavation in all kinds of soil and refilling of cavity around the pit & painting the iron works, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge 1.40m dia x 2.00m deep soakway pit |
| 363 | Construction of 50 users RCC septic tank (2Nos) Earth work in excavation of foundation in all kinds of soil within 50m initial lead and 1.5m initial lift including rough dressing & breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.30m in depth and as per direction of the Engineer-in-Charge. |
| 364 | Extra lifts of 1.50 mtr or part thereof over the initial lift of 1.5 mtr in all kinds of embankments and road works and ordinary earthwork in general. |
| 365 | Supplying all materials, labour, T&P and providing cement concrete (1:3:6) with 4cm size hard granite metal including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge In ground floor |
| 366 | Supplying all materials, labour, T&P and providing shoring and shuttering for foundation trenches, pits etc with close wooden planks or sheets shuttering etc all complete as per specification and direction of the Engineer in charge |
| 367 | Supplying all materials, labour, T&P and providing rigid and smooth centering and shuttering for R.C.C works including false work and dismantling them after casting including conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge R.C.C floor and roof slabs up to 4.30m height |
| 368 | RCC beam,Column, girders and bressmer etc |
| 369 | Supplying all materials, labour, T&P and providing M.S reinforcement for R.C.C work including cutting, bending, binding, and tying the grills and placing in position including cost of binding wire 18 to 20 gauge, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge In ground floor |
| 370 | Supplying all materials, labour,T&P and providing cement concrete(1:1 ½:3) with 12mm size hard broken granite chips for R.C.C works including hoisting, laying, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge.In ground floor |
| 371 | Supplying all materials, labour, T&P and providing 12mm thick cement plaster (1:3) on brickwork including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in chargeIn ground floor (inside/outside) |
| 372 | Supplying all materials, labour, T&P and providing cement punning including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge In ground floor (inside/outside) |
| 373 | Supplying all materials, labour, T&P and making MS step iron in 20mm diameter MS steel bars and fixing into walls of man hole/septic tank duly embedded in cement concrete (1:3:6) complete as per specification and direction of the Engineer in charge. |
| 374 | Supplying all materials, labour, T&P and providing brick work with fly ash bricks having crushing strength not less than 75kg/cm² with dimensional tolerance ± 8 percent in cement mortar (1:4) including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge In foundation and plinth |
| 375 | Supplying all materials, labour,T&P and providing Vent base in cement concrete(1:2:4) with 12mm size hard broken granite chips for R.C.C works including hoisting, laying, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 376 | Supplying all materials, labour, T&P and fitting and fixing UPVC SWR soil waste ventilating pipes and fittings to walls with nails, bobbins and wooden plugs or laying in trenches including earthwork in excavation in all kinds of soil and refilling of trenches as per specification and direction of the engineer in charge.110mm diameter U-PVC SWR pipe |
| 377 | 110mm dia U-PVC Plain shoe bend |
| 378 | 110mm dia U-PVC Cowl |
| 379 | Filling in foundation and plinth with excavated materials, moorum including watering and ramming as directed by the Engineer in charge |
| 380 | Sinking of 150mm dia tubewell through hand boring (water jet ) method (2nos) .Supplying all materials, labour, T&P and setting up boring equipments including erection of suitable staging for installation of the required size of tube well, dismantling and removing the same after complection of the work, including transportation of the boring equipments, cleaning and levelling the site, excavation of mud pit, channels etc, levelling of site all complete as per direction of Engineer in charge |
| 381 | Supplying all labour, T&P and transporting the boring pipes, top casing , grouting pipes, P.V.C pipes and fittings, P.V.C well screens, cement, bentonite and gravels etc to the worksite including loading and unloading etc all complete as per direction of Engineer in charge |
| 382 | Supplying all labour, T&P and drilling pilot bore not less than 102mm dia, without casing pipes in all kinds of soils and rocks for the following depths excluding supply of necessary boring pipes including supply of necessary cutting equipments, extra sockets (whenever required) etc and withdrawing the boring pipes, washing and keeping the bore clear for logging if required all complete as per direction of Engineer in charge. Drilling pilot bore from 0 to 360 metres |
| 383 | Supplying all required labour for logging the bore through departmental logging team (till logging team arrives at the site, the contractor is to keep the bore intact by circulating mud through the mud circulating system) and when the logging team arrives at the site, the contractor will withdraw the boring pipe with cutter etc. and keep the bore suitable for loggifng and supply required labour to carry out the logging operation. |
| 384 | Supplying all labour, T&P and reaming the pilot bore to the following sizes and depths without casing pipes including withdrawing the boring pipes, washing the bore by means of pipe cylinder etc all complete as per direction of Engineer in charge Reaming 100mm to 150mm dia from 0 to 360 metres |
| 385 | Reaming 150mm to 200mm dia from 0 to 360 metres |
| 386 | Reaming 200 mm to 250mm dia from 0 to 360 metres |
| 387 | Supplying all labour, T&P and jointing materials and lowering the 300mm dia top casing pipes into the position and removing the same after use all complete as per direction of Engineer in charge from 0 to 360 metres |
| 388 | Supplying all labour T&P and grouting with cement slurry for saline sealing in the bore around the 150 mm dia PVC casing pipe etc all complete as per the direction of the Engineer in charge. |
| 389 | Supplying all labour, T&P and jointing materials and lowering the pvc casing pipes, fittings and well screens in position, including fitting and fixing of centraliser, cutter plug and washing the bore all complete as per direction of Engineer in charge 150mm dia PVC casing pipe from 0 to 360 metres |
| 390 | Cost of 150mm dia PVC ASTM pipe (sch-80) |
| 391 | Cost of Cutting slot for 150mm dia PVC well screen |
| 392 | Cost of 150 mm dia C.I. cutter plug |
| 393 | Cost of bentonite powder |
| 394 | Supplying all materials, labour, T&P and packing the bore with washed gravel of river shingles of required size and specification around the well screen and pipe etc all complete as per the direction of the Engineer in charge |
| 395 | Cost and Conveyance of Gravel |
| 396 | Supplying all materials, labour, T&P and packing the bore with river sand over the gravel pack etc all complete as per the direction of the Engineer in charge |
| 397 | Cost and Conveyance of sand |
| 398 | Supplying all labour T&P and grouting with cement slurry for sanitary sealingin the bore around the upper most 3 metres of 150mm dia PVC casing pipe etc all complete as per the direction of the Engineer in charge. |
| 399 | Cost of Cement |
| 400 | Cleaning and developing the tube well with supply of compressor worked till clear and adequate discharge is obtained from the tube well including supply and use of all necessary equipment and labour as per direction of the Engineer in charge By Compressor |
| 401 | Supplying all materials, labour, T&P and providing, fitting and fixing submersible pump with squirrel cage induction type submersible type submersible electric motor to run on 3 phase/1 phase line voltage ranging from 320 volt to 450 volt conforming to IS: 8034/89 with following specifications with suitable control panel, jointing with GI/PVC/HDPE pipes, electrification, testing, commissioning, trial running, conveyance of all materials to worksite, payment of taxes etc all complete as per specification and direction of the Engineer in charge 2 H.P three phase 3 stage head range 30 to 54 metres, discharge 155 to 110 L.M.P with outlet dia of 32mm |
| 402 | DOL Control panel |
| 403 | 40mm dia steel short piece |
| 404 | Well cap |
| 405 | 50mm size CI bracket |
| 406 | 2.50sqmm flat cable |
| 407 | 20mm dia rigid UPVC pipes |
| 408 | Steel rope with cover |
| 409 | 32mm dia HDPE pipe |
| 410 | Labour charges for lowering including transportation |
| 411 | Supplying all materials, labour, T&P and constructing Bore well protection chamber of the inside size 650x650x1000hight with cement concrete (1:3:6) using 40mm size hard granite metal on foundation, 1st class Fly ash brickwork in cement mortar (1:3), with base cement concrete (1:2:4) using 12mm size h.g chips,12mmthick cement plaster (1:4) inside and outside, R.C.C cover slab in (1:1.5:3) using 12mm size h.g chips, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail