| Sl. No. | Item Description |
| 1 | GROUND FLOOR2.8 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means in foundation trenches or drains (not exceeding 1.5 m or 10sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50m2.8.1 All kinds of soil |
| 2 | 2.25 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50m and lift upto 1.5m |
| 3 | 2.27 Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete |
| 4 | 4.1 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :4.1.5 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 5 | 5.1 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 6 | 5.2 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 7 | 5.3 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 8 | 5.9 Centering and shuttering including strutting, propping etc. and removal of form for5.9.3 Suspended floors, roofs, landings, balconies and access platform |
| 9 | 5.9.1 Foundations, footings, bases of columns, etc. For mass concrete |
| 10 | 5.9.5 Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 11 | 5.9.6 Columns, Pillars, Piers, Abutments, Posts and Struts |
| 12 | 6.1 Brick work with common burnt clay FPS (non modular) bricks of class designation 7.5 in foundation and plinth inCement mortar 1:4 ( 1 cement : 4 coarse sand) |
| 13 | 6.13 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. |
| 14 | 9.1 Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately)Sal wood |
| 15 | 9.5 Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:- Butt hinges and necessary screws shall be paid separately)9.5.2 Kiln seasoned and chemically treated hollock wood9.5.2.1 35mm thick shutters |
| 16 | 9.119 Providing and fixing factory made P.V.C. door frame of size 50x47 mm with awall thickness of 5 mm, made out of extruded 5mm rigid PVC foam sheet, mitred at corners and joined with 2 Nos of 150 mm long brackets of 15x15 mm M.S. square tube, the vertical door frame profiles to be reinforced with 19x19 mm M.S. square tube of 19 gauge, EPDM rubber gasket weather seal to be provided through out the frame. The door frame to be fixed to the wall using M.S. screws of 65/100 mm size, complete as per manufacturer’s specification and direction of Engineer in-Charge. |
| 17 | 9.120 Providing and fixing factory made panel PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 19 mm x 19 mm for styles and 15x15 mm for top & bottom rails. M.S. frame shall have a coat of steel primers of approved make and manufacture. M.S. frame covered with 5 mm thick heat moulded PVC 'C' channel of size 30 mm thickness, 70 mm width out of which 50 mm shall be flat and 20 mm shall be tapered in 45 degree angle on both side forming styles and 5 mm thick, 95 mm wide PVC sheet out of which 75mm shall be flat and 20 mm shall be tapered in 45 degree on the inner side to form top and bottom rail and 115 mm wide PVC sheet out of which 75 mm shall be flat and 20 mm shall be tapered on both sides to form lock rail. Top, bottom and lock rails shall be provided both side of the panel. 10 mm (5 mm x 2 ) thick, 20 mm wide cross PVC sheet be provided as gap insert for top rail & bottom rail, paneling of 5 mm thick both side PVC sheet to be fitted in the M.S. frame welded/ sealed to the styles & rails with 7 mm (5 mm+2 mm) thick x 15 mm wide PVC sheet beading on inner side, and joined together with solvent cement adhesive. An additional 5 mm thick PVC strip of 20 mm width is to be stuck on the interior side of the 'C' Channel using PVC solvent adhesive etc. Complete as per direction of Engineer-in-charge, manufacturer's specification & drawing.9.120.1 30m thick plain PVC door shutters |
| 18 | 21.1 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :21.1.1 For fixed portion21.1.1.2 Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 19 | 21.1.2 For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately)21.1.2.2 Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 20 | 21.3 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):21.3.1 With float glass panes of 8.0mm thickness (weight not less than 20kg/sqm) |
| 21 | 9.55 Providing and fixing ISI marked M.S. pressed butt hinges bright finished with necessary screws etc. Complete :9.55.2 100 x 58 x 1.9mm |
| 22 | 9.63 Providing and fixing ISI marked oxidised MS tower bolt black finish (barrel type) with necessary screws etc. Complete9.63.2 200 x 10 mm |
| 23 | 9.103 Providing and fixing bright finished brass 100 mm mortice latch and lock, ISI marked, with six levers and a pair of anodised (anodic coating not less than grade AC 10 as per IS : 1868) aluminium lever handles of approved quality with necessary screws etc. Complete |
| 24 | Aluminium latch and handles |
| 25 | 9.66 Providing and fixing ISI marked oxidised MS handles conforming to IS:4992 with necessary screws etc. Complete:9.66.1 125mm |
| 26 | 5.22 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.5.22.6 Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 27 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 28 | 11.41 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting thejoints with white cement and matching pigments etc., complete. |
| 29 | 11.41.2 size of tile 600x600mm11.41A.3 Glazed vitrified tiles matt/anti-skid finish of size 600x600mm |
| 30 | 8.31 Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade Complete. |
| 31 | 13.1 12mm cement plaster of mix13.1.1 1:4 (1 cement: 4 sand) |
| 32 | 13.26 Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete |
| 33 | 13.48 Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of Special primer applied @ 0.75 ltr /10 sqm |
| 34 | FIRST FLOOR5.2 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 35 | 5.3 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 36 | 5.9 Centering and shuttering including strutting, propping etc. and removal of form for5.9.3 Suspended floors, roofs, landings, balconies and access platform |
| 37 | 5.9.5 Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 38 | 5.9.6 Columns, Pillars, Piers, Abutments, Posts and Struts |
| 39 | 6.13 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. |
| 40 | 9.1 Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately)Sal wood |
| 41 | 9.5 Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:- Butt hinges and necessary screws shall be paid separately)9.5.2 Kiln seasoned and chemically treated hollock wood9.5.2.1 35mm thick shutters |
| 42 | 9.119 Providing and fixing factory made P.V.C. door frame of size 50x47 mm with awall thickness of 5 mm, made out of extruded 5mm rigid PVC foam sheet, mitred at corners and joined with 2 Nos of 150 mm long brackets of 15x15 mm M.S. square tube, the vertical door frame profiles to be reinforced with 19x19 mm M.S. square tube of 19 gauge, EPDM rubber gasket weather seal to be provided through out the frame. The door frame to be fixed to the wall using M.S. screws of 65/100 mm size, complete as per manufacturer’s specification and direction of Engineer in-Charge. |
| 43 | 9.120 Providing and fixing factory made panel PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 19 mm x 19 mm for styles and 15x15 mm for top & bottom rails. M.S. frame shall have a coat of steel primers of approved make and manufacture. M.S. frame covered with 5 mm thick heat moulded PVC 'C' channel of size 30 mm thickness, 70 mm width out of which 50 mm shall be flat and 20 mm shall be tapered in 45 degree angle on both side forming styles and 5 mm thick, 95 mm wide PVC sheet out of which 75mm shall be flat and 20 mm shall be tapered in 45 degree on the inner side to form top and bottom rail and 115 mm wide PVC sheet out of which 75 mm shall be flat and 20 mm shall be tapered on both sides to form lock rail. Top, bottom and lock rails shall be provided both side of the panel. 10 mm (5 mm x 2 ) thick, 20 mm wide cross PVC sheet be provided as gap insert for top rail & bottom rail, paneling of 5 mm thick both side PVC sheet to be fitted in the M.S. frame welded/ sealed to the styles & rails with 7 mm (5 mm+2 mm) thick x 15 mm wide PVC sheet beading on inner side, and joined together with solvent cement adhesive. An additional 5 mm thick PVC strip of 20 mm width is to be stuck on the interior side of the 'C' Channel using PVC solvent adhesive etc. Complete as per direction of Engineer-in-charge, manufacturer's specification & drawing.9.120.1 30m thick plain PVC door shutters |
| 44 | 21.1 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :21.1.1 For fixed portion21.1.1.2 Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 45 | 21.1.2 For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately)21.1.2.2 Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 46 | 21.3 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):21.3.1 With float glass panes of 8.0mm thickness (weight not less than 20kg/sqm) |
| 47 | 9.55 Providing and fixing ISI marked M.S. pressed butt hinges bright finished with necessary screws etc. Complete :9.55.2 100 x 58 x 1.9mm |
| 48 | 9.63 Providing and fixing ISI marked oxidised MS tower bolt black finish (barrel type) with necessary screws etc. Complete9.63.2 200 x 10 mm |
| 49 | 9.103 Providing and fixing bright finished brass 100 mm mortice latch and lock, ISI marked, with six levers and a pair of anodised (anodic coating not less than grade AC 10 as per IS : 1868) aluminium lever handles of approved quality with necessary screws etc. Complete |
| 50 | Aluminium latch and handles |
| 51 | 9.66 Providing and fixing ISI marked oxidised MS handles conforming to IS:4992 with necessary screws etc. Complete:9.66.1 125mm |
| 52 | 5.22 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.5.22.6 Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 53 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 54 | 11.41 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting thejoints with white cement and matching pigments etc., complete. |
| 55 | 11.41.2 size of tile 600x600mm11.41A.3 Glazed vitrified tiles matt/anti-skid finish of size 600x600mm |
| 56 | 8.31 Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade Complete. |
| 57 | 13.1 12mm cement plaster of mix13.1.1 1:4 (1 cement: 4 sand) |
| 58 | 13.26 Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete |
| 59 | 13.48 Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of Special primer applied @ 0.75 ltr /10 sqm |
| 60 | TERRACE FLOOR5.2 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 61 | 5.3 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 62 | 5.9 Centering and shuttering including strutting, propping etc. and removal of form for5.9.3 Suspended floors, roofs, landings, balconies and access platform |
| 63 | 5.9.5 Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 64 | 5.9.6 Columns, Pillars, Piers, Abutments, Posts and Struts |
| 65 | 6.13 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. |
| 66 | 9.1 Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately)Sal wood |
| 67 | 9.5 Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:- Butt hinges and necessary screws shall be paid separately)9.5.2 Kiln seasoned and chemically treated hollock wood9.5.2.1 35mm thick shutters |
| 68 | 9.55 Providing and fixing ISI marked M.S. pressed butt hinges bright finished with necessary screws etc. Complete :9.55.2 100 x 58 x 1.9mm |
| 69 | 9.63 Providing and fixing ISI marked oxidised MS tower bolt black finish (barrel type) with necessary screws etc. Complete9.63.2 200 x 10 mm |
| 70 | 9.66 Providing and fixing ISI marked oxidised MS handles conforming to IS:4992 with necessary screws etc. Complete:9.66.1 125mm |
| 71 | 13.1 12mm cement plaster of mix13.1.1 1:4 (1 cement: 4 sand) |
| 72 | 13.26 Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete |
| 73 | 13.48 Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of Special primer applied @ 0.75 ltr /10 sqm |
| 74 | INTERNAL ELECTRICAL WORKSWIRING1.1 Wiring for light point/fan point/Exhaust fan point/Call bell point with 1.5 sq mmFRLS PVC Conductor single core cable in surface/recessed medium class PVC conduit with modular switch, modular plates, suitable GI box and earthing the Point with 1.5 sq mm FRLS PVC insulated conductor single core cable etc,as required1.1.3 Group C |
| 75 | 1.12 Wiring for Light/Power plug with 2x4 sqmm FRLS PVC insulated copper conductor single core in surface/recessed medium class PVC conduit along with 1 no. 4.00 sq mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 76 | 1.7 Wiring for circuit/sub-main wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor,single core cable in surface/recessed medium class PVC conduit as required.1.7.1 2x1.5 sqmm + 1x1.5 sqmm earth wire |
| 77 | 1.7.2 2x2.5 sqmm + 1x2.5 sqmm earth wire |
| 78 | 1.7.3 2x4.0 sqmm + 1x4.0 sqmm earth wire |
| 79 | 1.22 Supplying and fixing metal box of following sizes(nominal size) on surface or recess with suitable size of Phenolic laminated sheet cover in front including painting etc. As required1.22.2 100mm x 100mm x 60mm deep |
| 80 | 1.22.5 180mm x 100mm x 60mm deep |
| 81 | 1.22.16 250mm x 300mm x 100mm deep |
| 82 | 1.24 Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required1.24.1 5/6A switch |
| 83 | 1.24.3 15/16A switch |
| 84 | 1.24.4 3 pin 5/6A socket outlet |
| 85 | 1.24.5 6pin 15/16A socket outlet |
| 86 | 1.25 Supplying and fixing two module steeped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate as required |
| 87 | 1.26 Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required |
| 88 | 1.27 Supplying and fixing following size/modules GI box along with modular base & cover plate for modular switches in recess etc. As required1.27.1 1 or 2 module (75mm x 75mm) |
| 89 | 1.27.2 3 module (100mm x 75mm) |
| 90 | 1.27.4 6 module (200mm x 75mm) |
| 91 | 1.27.5 8 module (125 x 125mm) |
| 92 | 1.27.6 12 module (200mm x 150mm) |
| 93 | 1.31 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess,including providing and fixing 3 pin 5/6A modular Socket and 5/6A modular switch connection etc. as required. |
| 94 | 1.32 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess,including providing and fixing 6 pin 15/16A modular socket 15/16A modular switch, connection etc. as required. |
| 95 | 1.41 Installation testing and commissioning of pre- wired fluorescent fitting/compact fluorescent fitting of all types complete with all accessories and tube etc directly on ceiling/wall including connection with 1.5 sq mm FRLS PVC insulated copper conductor,single core cable and earthing etc. As required |
| 96 | 1.45 Installation testing and commissioning of ceiling fan including wiring the down rods of length of standard length(upto 30cm) with 1.5 sq mm FRLS PVC insulated copper conductor,single core cable including providing and fixing phenolic laminated sheet cover on the fan box etc. As required |
| 97 | 1.50 Installation of exhaust fan in the existing opening including making good the damage, connection,testing and commissioning as required1.51.1 Upto 450mm sweep |
| 98 | 4.1 Supplying and installing following size of perforated painted with powder coating M.S. cable trays bends with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.4.2.1 300mm x 50mm x 2mm |
| 99 | MCCB, MCS & DB's2.4 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. As required. (But without MCB/RCCB/lsolator)2.4.1 4 way (4+12) Double door |
| 100 | 2.3.2 12 way (8+36) Double door |
| 101 | 2.10 Supplying and fixing 6Amps to 32 amps rating,240/415V “c” curve miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections,testing and commissioning etc. as required2.10.1 Single pole |
| 102 | 2.10.3 Double pole |
| 103 | 1.10.4 Triple pole |
| 104 | 2.12 Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.2.12.1 40 A |
| 105 | 2.12.2 63 A |
| 106 | 2.13 Supplying and fixing following rating, four pole, 415 V, isolator in theexisting MCB DB complete with connections, testing andcommissioning etc. as required.2.13.1 40 A |
| 107 | 2.13.2 63 A |
| 108 | 2.13.3 100 A |
| 109 | SERVICE CONNECTION7.5 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.7.5.1 Upto 35 sqmm |
| 110 | 7.5.2 Above 35s sqmm and upto 95 sqmm |
| 111 | MR- Supply of one number XLPE insulated and PVC sheathed aluminium conductor armoured power cable of 1.1 KV grade with ISI marked (IS 7098 part I) 1988 of following sizes3.5 x 35 sqmm |
| 112 | 3.5 x 95 sqmm |
| 113 | 9.1 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required9.1.21 3.5 x 35 sqmm (32mm) |
| 114 | 9.1.24 3.5 x 95 xqmm (45sqmm) |
| 115 | 14.15 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. Conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required.14.15.1 63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 116 | EARTHING5.6 Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre lonq etc. with charcoal/ coke and salt as required. |
| 117 | 5.19 Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required |
| 118 | 14.15 Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing. |
| 119 | Supplying installation,testing and commission of Superior finish extruded LED batten White powder coated pressure die cast aluminium body with high transitivity non yellowing PMMA diffuser with driver and accessories pre-wired upto terminal box assembly LED Liminaires of make PHILLIPS Cat No. BN021C LED 20S PSU CDL G LED 18W or equivalent including lamp etc.complete(TL) |
| 120 | Supply, fitting and fixing of ceiling mounted circular downlighter fixtures of CGL make ( Cat. LHEAAHP6IL1W018 ) of 18W Panel Light (Round) 18W fittings or equivelent make of Havells/Syska/Bajaj/Philips |
| 121 | Supply, fitting and fixing of round LED bulbs of Havells/Syska/Philips/Bajaj or equivalent make of 12watt(cat LED PLUS 12 W B22 CDL Lamp LHLDDDBNL5R012) |
| 122 | Supply and fitting of 250mm sweep exhaust fan of make Havells/Philips/ etc or equivalent make (cat FHVTADXWHT10) |
| 123 | 19.1 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copperwinding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required |
| 124 | LANWORK4.53 Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required.1.53.1 1 run of cable |
| 125 | SANITARY2.8 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means in foundation trenches or drains (not exceeding 1.5 m or 10sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50m2.8.1 All kinds of soil |
| 126 | 2.27 Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete |
| 127 | 16.12 Dry brick pitching half brick thick in drains including supply of bricks and preparing the surface 16.12.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 128 | 4.1 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :4.1.3 1:2:4 (1 cement: 2 coarse sand (zone-Ill) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 129 | 5.1 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost ofcentering, shuttering, finishing and reinforcement - All work up to plinth level:5.1.2 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 130 | 5.9 Centering and shuttering including strutting, propping etc. and removal of form for5.9.1 Foundations, footings, bases of columns, etc. For mass concrete |
| 131 | 5.9.3 Suspended floors, roofs, landings, balconies and access platform |
| 132 | 5.9.13 Vertical and horizontal fins individually or forming box louvers band, facias and eaves boards |
| 133 | 6.2 Brick work with common burnt clay FPS (non modular) bricks of class designation 7.5 in foundation and plinth in6.2.1 Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 134 | 6.13 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.6.13.2 Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 135 | 5.22 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.5.22.6 Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 136 | 13.2 15mm cement plaster on the rough side of single or half brick wall of mix13.2.1 1:4 (1 cement: 4 sand) |
| 137 | 11.6 Cement plaster skirting up to 30cm height with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement.18.6.1 18mm thick |
| 138 | 17.3 Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :17.3.1 WC pan with ISI marked white solid plastic seat and lid |
| 139 | 17.5 Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required :17.5.1 Single half stall urinal with 5 litre P.V.C. automatic flushing cistern |
| 140 | 17.7A Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:-(a) White Vitreous China wash basin of size 550x400 mm with 15 mm C.P. brass single hole basin mixer |
| 141 | 17.28 Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.17.28.1 Semi rigid pipe, 40mm dia |
| 142 | 17.31 Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 143 | 17.34 Providing and fixing toilet paper holder:17.34.1 CP brass |
| 144 | 17.35 Providing and fixing soil, waste and vent pipes17.35.1 100mm dia17.35.1 Sand cast iron S&S pine as per IS: 1729 |
| 145 | 17.6 Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors:17.60.1 100 mm inlet and 100 mm outlet17.60.1.1 Sand cast iron s&s as per IS: 3989 |
| 146 | 17.61 Cutting chases in brick masonry walls for following diameter sand cast iron/centrifugally cast (spun) iron pipes and making good the same with cement concrete 1:3:6 ( 1 cement : 3 coarse sand :6 graded stone aggregate 12.5 mm nominal size), including necessary plaster and pointing in cement mortar 1:4 (1 cement: 417.61.1 100 mm dia |
| 147 | 17.69 Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour.17.69.1 Waste coupling 31 mm dia of 79 mm length and 62mm breadth weighing not less than 45 gms |
| 148 | 17.70 Providing and fixing PTMT Bottle Trap for Wash basin and sink.17.70.1 Bottle trap 31mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 gms |
| 149 | 17.71 Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. |
| 150 | 17.72 Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms. |
| 151 | 18.15 Providing and fixing brass bib cock of approved quality:18.15.2 20 mm nominal bore |
| 152 | 18.16 Providing and fixing brass stop cock of approved quality18.16.2 20 mm nominal bore |
| 153 | 18.8 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc18.8.1 15 mm dia nominal outer dia pipes |
| 154 | 18.8.2 20 mm dia nominal outer dia pipes |
| 155 | 18.8.3 25 mm dia nominal outer dia pipes |
| 156 | 18.8.4 32 mm dia nominal outer dia pipes |
| 157 | 18.9 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charg18.9.1 32 mm dia nominal dia pipes |
| 158 | 18.9.5 40 mm dia nominal dia pipes |
| 159 | 18.10 Providing and fixing G.l. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc18.10.1 Internal work - Exposed on wall 15 mm dia nominal bore |
| 160 | 18.12 Providing and fixing G.l. pipes complete with G.I. fittings intemal work - Exposed on wall18.12.2 20 mm dia nominal bore |
| 161 | 18.12.4 32 mm dia nominal bore metre |
| 162 | 18.13 Providing and fixing gun metal non- return valve of approved qualitv (screwed end):18.13.1 20 to 40 mm nominal bore |
| 163 | 18.17 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end)18.17.1A 20 mm nominal bore |
| 164 | 18.17.2 32 mm nominal bore |
| 165 | 18.17.3 40 mm nominal bore |
| 166 | 18.19 Providing and fixing gun metal non- return valve of approved quality (screwed end):18.19.3 40 mm nominal bore18.19.3.1 Horizontal |
| 167 | 18.19.3.2 Vertical |
| 168 | 18.21 Providing and fixing uplasticised PVC connection pipe with brass unions:18.21.1 30 cm length18.21.1.1 15 mm nominal bore |
| 169 | 18.21.1.2 20 mm nominal bore |
| 170 | 18.48 Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank |
| 171 | 18.42 Boring with 100 mm diameter casing pipe for hand pump / tubewell, in all soils except ordinary hard rocks requiring blasting, including removing the casing pipe after the hand pump / tube well is lowered and tested :18.42.2 Beyond 6 m and up to 12 m depth |
| 172 | 18.42.3 Beyond 6 m and up to Required depth |
| 173 | 18.43 Providing and placing in position filters of 40mm diameter GI pipe with brass strainer of approved quality |
| 174 | 18.44 Providing and fixing to filter and lowering to proper levels 40 mm G.I. pipe for tube well including cleaning and priming the tube well. |
| 175 | 18.45 Providing and placing in position hand pump of approved quality for 40 mm diameter G.I. pipe complete with all accessories |
| 176 | 18.46 Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New Work) :18.46.6 50mm nominal bore |
| 177 | Reducing socket, valve, etc |
| 178 | 6. FIRE FIGHTING1.7.1 Supplying, installation, testing & commissioning of heat detector operating at 54°C/57°C with rate of rise cum fixed tempreature (dual thermistor) type with mounting base complete with all connection etc. as required. |
| 179 | 17.1.2 Supplying, installation, testing & commissioning of smoke detector with builtin LED and mounting base complete with all connections etc. as required. |
| 180 | 17.1.3 Supplying, installation, testing & commissioning of manual call boxes of MS construction in surface/recess with stainless steel chain & hammer assembly complete with glass and push button etc. As required |
| 181 | 17.1.5 Supplying, installation, testing & commissioning response indicator on surface/recess MS box having two LEDs metallic cover complete with all connections etc. as required. |
| 182 | 17.1.6 Supplying, installation, testing & commissioning fire alarm sounder with facility to make announcement, mounted in M.S. box (16 SWG) with hinged cover plate & suitable for operation with amplifier i/c line matching transformer etc. complete as required. |
| 183 | 17.1.9 Supplying, installation, testing & commissioning sector panel suitable for following zones, complete with visual indications for short circuit fault, open circuit fault, fire condition and all other standard facilities as per IS:2189 with mimic diagram for all area/zone covered, complete with all connections, interconnections as required.17.1.9.1 4 zone |
| 184 | 17.5.1 Supplying & laying of 2x1.5 sqmm fire survival armoured cable, 600/1000V rated with annealed copper conductor having glass mica fire barrier tape covered by an extruded layer of Cross Linkable Ethylene Propylene Rubber (EPR) insulation and LSZH inner bedding, steel wire armouring & LSZH outer sheath complete as Required |
| 185 | 17.5.3 Supplying and drawing of cable Fire Retardant PVC insulated copper conductor cable in the existing surface / recessed steel conduit of following pairs, cores and size including connections and interconnections etc. as required17.5.3.1 speaker cable Single pair, 2-core, 1.5 sqmm |
| 186 | FIRE EXTINGUISHERSProviding and fixing Carbon di-oxide fire extinguishers consisting of welded M.S. cylindrical body, squeeze lever discharge valve 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket, ISI marked as per IS:15683 finished externally with red enamel paint and fixed to wall with brackets complete with internal charge suitable for electrical fires. (Make: Ceasefire / Steelage/Lifeguard). Capacity: 4.5 kg |
| 187 | Providing and fixing Carbon di-oxide Wheeled fire extinguishers consisting of welded S.S. cylindrical body,as per IS 16018 specifications suitable for electrical fires(Make: Ceasefire/Lifeguard/SafetyPlus)Capacity: 9 kg |
| 188 | Providing and fixing Carbon di-oxide fire extinguishers consisting of welded M.S. cylindrical body, squeeze lever discharge valve, discharge nozzle, suspension bracket, ISI marked as per IS:15683 finished externally with red enamel paint and fixed to wall with brackets complete with internal charge suitable for electrical fires. (Make: Ceasefire / Steelage/Lifeguard). Capacity: 2 kg Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |