| 1 | 2.13 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.-All kinds of soil |
| 2 | 2.16 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.-All kinds of soil |
| 3 | 2.19 Supplying and filling in plinth, under floor, foundations etc. with sand (fine) from local quarry with all lifts including spreading in horizontal layers, watering, grading torequired slope, ramming, consolidating and compacting each layer by using plate compactor or by any suitable method complete. |
| 4 | 4.1 Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering --All work upto plinth level:4.1.7 1:4:8 ( 1 Cement: 4 fine sand : 8 graded stone aggregate 40 mm nominal size) |
| 5 | 4.1.14 1:3:6 ( 1 Cement: 3 fine sand : 6 graded well burnt brick aggregate 40 mm nominal size) |
| 6 | 4.4 Centering shuttering including struttings, propping etc. and removal of form work for:4.4.1 Foundations, footings, bases for columns. |
| 7 | 5.1 Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring, shuttering, finishing and reinforcement--All work upto plinth level:5.1.2 1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stone aggregate 20 mm nominal size) |
| 8 | 5.2 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and skirting courses, fillets, columns, pillars, piers, abutments, posts and struts etc. upto floor five level excluding cost of centring, shuttering, finishing and reinforcement-5.2.2 1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stone aggregate 20 mm nominal size) |
| 9 | 5.3 Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto floor five level excluding the cost of centring, shuttering, finishing andreinforcement-5.3.2 1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stone aggregate 20 mm nominal size) |
| 10 | 5.8 Centering shuttering including struttings, propping etc. and removal of form work for:5.8.1.1 Foundations, footings, bases for columns etc. for mass concrete with timber plank |
| 11 | 5.8.6.2 Columns, Pillars, Piers, Abutments, Posts and Struts with wooden plank |
| 12 | 5.8.5.2 Lintels, beams, plinth beams, girders, bressumers and cantilevers with wooden plank |
| 13 | 5.8.13 Weather shade, Chajjas, corbels etc., including edges. |
| 14 | 5.19 Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.5.19.4 Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 15 | 6.1 First class brick work in foundation and plinth including cost of all materials as required complete:-6.1.5 In cement mortar 1:6 ( 1 cement : 6 fine sand ). |
| 16 | 6.15 1st class brick masonry work 75mm thick in superstructure upto floor five level including cost of all materials as required complete:-6.15.1 In cement mortar 1:3 ( 1 cement : 3 fine sand ). |
| 17 | 6.12 Half brick masonry work with first class bricks in superstructure upto floor five level including cost of all materials as required complete:-6.12.3 In cement mortar 1:4 ( 1 cement : 4 fine sand ). |
| 18 | 8.4 Providing wood work in frames of false ceiling, partitions etc. sawn and put up in position :8.4.2 Karai Wood |
| 19 | 8.46 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. all complete.8.46.2 Fixed to openings /wooden frames with rawl plugs screws etc. |
| 20 | 9.5 Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6mm angle iron and 3mm M.S. gusset plates at the junctions and corners, & with cleats with bolts & nuts, rivets, locking arrangement, handles, hooks & eyes, pinlets including embedding in cement concreteof required grade for fixing in position, all necessary fittings, including applying a priming coat of approved steel primer etc. complete as required:-9.5.1 Using M.S. angels 40x40x6 mm for diagonal braces. |
| 21 | 9.12 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.9.12.1 Hot finished welded type tubes |
| 22 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, completeupto any pitch in horizontal/ vertical or curvedsurfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required and as per direction of Engineer-in-charge. |
| 23 | 11.21 Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+ 0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete for Ridges/Valley/Gutter/Flashing of width 600mm etc. complete as per direction of Engineer-incharge. |
| 24 | 11.24 Providing and fixing insulating board ceiling of approved quality with necessary nails etc. complete as per direction of Engineer-in-charge. (frame work to be paid separately):11.24.1 12 mm thick natural colour insulating board |
| 25 | 10.5 Cement concrete flooring 1:2:4 (1 cement : 2 fine sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. all completeetc as per direction of Engineer-in-charge.10.5.1 40 mm thick with 20 mm nominal size stone aggregate |
| 26 | 12.1 12 mm cement plaster of mix12.1.2 Cement mortar 1:4 (1 cement : 4 fine sand) |
| 27 | 12.2 15 mm cement plaster on the rough side of single or half brick wall of mix:12.2.4 Cement mortar 1:6 (1 cement : 6 fine sand) |
| 28 | 12.10 Neat cement punning. |
| 29 | 12.34 Distempering with dry distemper of approved brand and manufacture (two or more coats) of required shade on new work, over and including water thinnable priming coat to give an even shade. [Payment shall be made after submission of Test Certificate issued by the Manufacturer] |
| 30 | 12.39 Finishing walls with water proofing cement paint of required shade of approved brand and manufacture [Payment shall be made after submission of Test Certificate issued by the Manufacturer] :12.39.1 New work ( two or more coats applied @ 3.84 kg/10 sqm) |
| 31 | 12.45 Applying priming coat [Payment shall be made after submission of Test Certificate issued by the Manufacturer] :12.45.1 With ready mixed Pink or Grey primer of approved brand and manufacture on wood work ( hard & soft wood ). |
| 32 | 12.60 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade [Payment shall be made after submission of Test Certificate issued by the Manufacturer]:12.60.1 Two or more coats on new work over an under coat of suitable shade with ordinary paint (primer) of approved brand and manufacture Please Enable Macros to View BoQ information |