| 1 | Design, fabrication, assemble, wiring and S/I/T/C of Panel enclosure Compartmentalized floor mounted single front, fixed type, fabricated from 2 mm thick CRCA Sheet, front operated cubicle type panel board having size suitable at site for operation 3 phase 4 wire 415 V 50 Hz supply and required size AL bus bar 400 amp panel mounting including outgoing cable and incoming cable of suitable rating connection/inter connection with solid bus bar/thimble/ ferrule making the earthing stub. Aluminum earth bus bar earth terminals danger plate, IP42,IS/IEC 61429 etc. complete as required and fitting with following accessories,Electric Pillar -1 Incoming(i) 400A 3 Pole MCCB 25KA with Adjustable setting for (TMD) – 2 Nos.(ii) RYB Indicating Lamps, 22.5 mm Dia LED Type – 1 No. (iii)Multifunction meter, Accuracy CI 1.0 – 1 No. (iv) Current Transformer – 3Nos. (v) 6A SP, MCB, 10kA , \\"C\\" Curve – 3 Nos.(vi) changeover switch400 A, FP, manual change over switch- 1 no.Outgoings(i) Busbar – 1 Nos. (ii) 10 Nos 63A, 3 pole MCCB 25 KA, Al Busbar – 1No. (Aluminum Bus bar having capacity suitable to with stand symmetrical fault level of 36 KA at 415 volt neutral bus bar is to be of 50% capacity.)(Minimum size of the panel should not be less than 2.70 sqmtr) . All theoutgoings cables /circuits have to be terminated with new end terminations after installation of the panel. Necessary masonry works required for the installation of the feeder panel should also be carried out by the tenderer |
| 2 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required 3½ X 185 sq. mm (45mm) |
| 3 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required Above 95 sq. mm and upto 185 sq. mm (clamped with25x3mm MS flat clamp) |
| 4 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole |
| 5 | Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63A |
| 6 | Supplying & fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve includingconnections, painting etc. as required |
| 7 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. Group C |
| 8 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 9 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 10 | 2 X 16 sq. mm + 1 X 6 sq. mm earth wire |
| 11 | 4 X 16 sq. mm + 2 X 6 sq. mm earth wire |
| 12 | Earthing with G.I. earth pipe 4.5-Meter-long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/coke and salt as required |
| 13 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 meter below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) |
| 14 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 16 way, Double door |
| 15 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. (Note: Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 12 way (4 + 36), Double door |
| 16 | Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required. |
| 17 | Supplying and fixing following rating, double pole, 240V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required 63A |
| 18 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connectionsetc. as required |
| 19 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 20 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. |
| 21 | Supply of Exhaust Fan 12\\"(300mm sweep), 1440 rpm corrosion resistant, energy efficient,low maintenance with a protective bird guard,delivers rapid air circulation with minimal noise Make: Crompton/Havells/Bajaj/Philips Min. 02 years warranty |
| 22 | Installation, Testing and Commissioning of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.Upto 450 mm sweep |
| 23 | Supply of 3.5*185 sq mm PVC insulated and PVC sheathed aluminum armored conductor cable Make: Polycab, havells,Finolex, RR kabel |
| 24 | SITC of LED 36W 2*2 Panel Light on surface/in recess ceiling Light CCT 4000K/6500K, System lumen efficacy min.120 lm/Watt, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Flicker free Make: Havells/Philips/Crompton/Goldwyn Min. 02 years warranty |
| 25 | SITC of LED 24W 1*1 Panel Light on surface/in recess ceiling Light CCT 4000K/6500K, System lumen efficacy min 105lm/Watt, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Flicker free Make : Havells/Philips/Crompton/Goldwyn Min. 02 years warranty |
| 26 | Supply, Installation, Testing and Commissioning ofceiling fan with Brush Less Direct Current (BLDC)Motor, class of insulation: B, 3 nos. metal( Aluminiumalloy) blades, 30 cm long down rod, 2 nos. canopies,shackle kit, safety rope, copper winding, steel/Al bodyPower Factor not less than 0.9, Service Value(CM/M/W) minimum as below, 350 RPM (tolerance asper IS : 374-2019), THD (Total Harmonic Distortion)less than 10%, suitable for operation with regulatorfor speed control and all remaining accessoriesincluding safety pin, nut bolts, washers, temperaturerise=75 0C (max.), insulation resistance more than 2mega ohm, suitable for 230 V, 50 Hz, single phase ACsupply, Ceiling Fan compliant to IS 374:2019 fan i/cexternal connections with 1.5 sq.mm FRLS/HFFR,PVC insulated copper conductor single core cableand earthing etc. as required.1200mm, service value ≥ 6.0 CM/Min/Watt, airdelivery 210 CM/Min (Minimum) |
| 27 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required Please Enable Macros to View BoQ information |