| 1 | Providing and fixing of 3 pin 6/10 amps plug point with modular type 6/10 amps switch and socket including connection with 2x1.5 sq. mm PVC insulated Copper conductor cable (FR) on surface modular switch board, earthing the 3rd pin etc. as required:- |
| 2 | Providing and fixing of 3/6 pin 16/20 amps plug point with modular type 16/20 amps switch and socket including connection with 2x2.5 sq. mm PVC insulated Copper conductor cable(FR) on surface modular switch board, earthing the 3rd pin etc. as required:- |
| 3 | Wiring for circuit /Sub-main with following sizes PVC insulated copper conductor cable (FR) in PVC casing and capping etc. as required. |
| 4 | 2 X 1.5 sq mm |
| 5 | 2 X 2.5 sq mm |
| 6 | Wiring for Circuit/Sub-main with the following sizes of PVC insulated Copper conductor cable (FR) in existing PVC casing capping/ conduit in recess/surface including connection etc. as required:- |
| 7 | 1 X 1.5 sq mm |
| 8 | Supplying and installation of powder coated steel sheet enclosure (MCB DB) suitable for 240/415 volts MCB/Isolator/RCCB (SP/SPN/DP/ TP/TPN/FP) complete with necessary bus bar, neutral link, din rail, earth bar etc i/c connection as required. |
| 9 | 2 way SPN MCB DB (Single door):- |
| 10 | 4 way SPN MCB DB (double door):- |
| 11 | Supplying & installation of 10 KA breaking capacity, B/C curve MCB of following ratings in the existing MCB DB including connection as required:- |
| 12 | 6 to 32 amps SP MCB:- |
| 13 | Supplying and fixing of MS frame made of (25mm x 25mm x 5mm) MS angle with necessary support by (40mm x 6mm) MS flat and 12 mm thick marine plywood on top, grouted on wall with 4 nos legs (25mmx25mmx5mm MS angle 20 cm long) finished with red oxide and 2 coat synthetic enamel paint including necessary cc work, mending the damages & painting etc as required:- |
| 14 | Supplying and installation of secure zone 4 kg ABC powder fire Extinguisher gross weight 6.38 kg, empty weight 2.38 kg, can height 372 mm, diameter 150 mm, discharge time minimum 13 seconds , discharge mechanism - squeeze grip type range minimum 2 meters applicable on class A,B,C and electrically started fire, A rating- 2A, raring-55B, can contrast- mig welded,valve construction- forging & machining, external coating of can..epoxy polyester powder coating, sheet metal thickness. 1.60mm, conforms to BIS standards, 5 years warranty :- |
| 15 | Supplying, installation, testing and commissioning of microprocessor based intelligent addressable main fire alarm panel, central processing unit with the following loop modules and capable of supporting not less than 240 devices (including detectors) and minimum 120 detectors per loop and loop length up to 2 km, network communication card, minimum 320 character graphics/ LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM), power supply unit (230± 5% V, 50 hz), 48 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall have facility to connect printer to printout log and facility to have seamless integration with analog/digital voice evacuation system through DVC and shall be complete with all accessories . The panel shall be compatible for IBMS system with open protocol BACnet/ Modbus over IP complete as perspecifications. |
| 16 | Ten Loop Panel:- |
| 17 | Supplying, installing, testing and commissioning of Addressable Multi-criteria Photo-Thermal Detector with sensitivity range of atleast 0.5 to 1.0% obs/ft .The intelligent multi criteria detection device shall include the ability to combine the signal of the thermal sensor with the signal of the photoelectric signal in an effort to react hastily in the event of a fire situation. It shall also include the inherent ability to distinguish between a fire condition and a false alarm condition by examining the characteristics of the thermal and smoke sensing chambers and comparing them to a database of actual fire and deceptive phenomena. The detector shall have twin bi-colour LED for 360 deg viewing. Addressing shall be with user friendly rotary decimal switches. The detector sensitivity (day & night) shall be controlled from the panel to get accustomed to the local environment. |
| 18 | Supplying, installation, testing & commissioning of response indicator on surface/recessed MS Box having two LED,metallic cover complete with all connections etc as required. |
| 19 | Supplying, installation, testing & commisssioning of intelligent addressable programmable sounder complete as required:- |
| 20 | Supplying, installation, testing & commissioning of addressable manual call point complete as required. |
| 21 | Supplying and drawing of cable Fire Retardant PVC insulated copper conductor cable in the existing surface / recessed steel/PVC conduit of following pairs, cores and size including connections and interconnections etc. as required. |
| 22 | Single pair 2-core 1.5 sqmm:- |
| 23 | Two pair 2-core 1.5 sqmm:- |
| 24 | Supplying and fixing of the following PVC conduit (medium gauge) with all accessories on slab/recessed on wall etc as required. |
| 25 | 19/20 mm dia :- |
| 26 | 19/20 mm dia :- |
| 27 | Supplying, installation, testing and commissioning of following ratings inverter with Square/ sine wave technology, noiseless operation, inbuilt advance PCB programming, microprocessorwith all accessories including necessary connections etc. as required:- |
| 28 | 900 VA, 12V DC, 1 Ph input/1 Ph output inverter(Sine wave technology):- |
| 29 | Supplying, installation, testing and commissioning of following ratings Valve regulated lead acid(VRLA) battery with all accessories including necessary connections etc. as required:- |
| 30 | 12 V/ 150AH tall tubular/ flat plate Battery:- Please Enable Macros to View BoQ information |