| 1 | DSR Item No. 1.10 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. |
| 2 | Group C |
| 3 | DSR item No.1.31 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. |
| 4 | DSR item No.1.32 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 5 | DSR item No.1.57 Supplying & fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required. |
| 6 | DSR Item No 1.17 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 7 | 3 x 1.5 sq. mm |
| 8 | 3 x 2.5 sq. mm |
| 9 | 3 x 4 sq. mm |
| 10 | DSR Item No. 1.21 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 11 | 25 mm |
| 12 | DSR item No.1.27 Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required. |
| 13 | 3 Module (100 mmX75 mm) |
| 14 | 6 Module (200 mmX75 mm) |
| 15 | DSR Item No.1.38 Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required. |
| 16 | DSR Item No. 1.33 Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. |
| 17 | DSR item No.1.24 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 18 | 5/6 amps switch |
| 19 | 3 Pin 5/6 A. socket outlet |
| 20 | DSR item No.1.26 Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 21 | DSR Item No. 2.4 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required (But without MCB/ RCCB/ Isolator). |
| 22 | 4 way (4 + 12) Double door |
| 23 | DSR Item No. 2.10 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 24 | Single pole |
| 25 | Triple pole and neutral |
| 26 | DSR Item No.1.14 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. |
| 27 | 4 X 10 sq. mm + 2 X 6 sq. mm earth wire |
| 28 | DSR item No.4.1 Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. |
| 29 | 150mmwidthX50mmdepthX1.6mmthickness |
| 30 | DSR item no. 8.6.10LED Panel light 2x2 ft. (System lumen efficacy ≥105 <120 lm/Watt)Supplying, installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, freq 50/60 hz, (As per Complete Item No. 16 of the DNIT). |
| 31 | 36 watt |
| 32 | DSR item no. 8.9.5LED Batten light (System lumen efficacy ≥105 <120 lm/Watt)Supplying, Installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, (As per Complete Item No. 17 of the DNIT). |
| 33 | 18- 22 watt |
| 34 | DSR Item No.2.5 Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required (Note: Vertical type MCB TPDB is normally used where 3 phase outlets are required). |
| 35 | 8 way (4 + 24), Double door |
| 36 | DSR item No.15.16 SupplyingandlayingoffollowingsizeDWCHDPEpipeISI markedalongwithallaccessorieslikesocket,bend,couplers etc.conforming toIS 14930, Part II complete with fitting and cutting, jointing etc. direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioningandprotectivecoveringetc.,completeasrequired. |
| 37 | 63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 38 | Supply and erection of sheet metal bus-bar chamber on existing surface with required No. of bus-bar strips of suitable length and cross-sectional area, made of copper strips of suitable length and cross-sectional area enclosure made of M.S. sheet 1.6mm thick with detachable cover fitted with dust excluding gasket and secured with sufficient No. (As per Complete Item No. 20 of the DNIT). |
| 39 | Sheet metal bus-bar chamber suitable for 200 Amp. 415 Volts capacity with 4 copper strip Bus-bars each of length 600 mm & cross-sectional area (50 mm x 4 mm) enclosure having overall dimensions (680mm x 450mm x 150mm) nominal. |
| 40 | DSR item no.8.16.3 LEDFlood powder coated pressure die cast aluminium (System lumen efficacy ≥120 and <135 lm/Watt) plying, installation, Testing & Commissioning o fFlood Light,powdercoatedpressuredie cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%,(As per Complete Item No. 21 of the DNIT). |
| 41 | 100 Watt |
| 42 | DSR item No.9.2.4 Brush Less Direct Current (BLDC) Fan without Remote Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, (As per Complete Item No. 22 of the DNIT). |
| 43 | 1400mm, service value ≥ 6.0 CM/Min/Watt, air delivery 245 CM/Min (Minimum) |
| 44 | Supply and laying of XLPE insulated PVC sheathed Aluminum conductor cable of 1.1 KV grade as per IS 7098 (Part-I) 1988 (amended up to date) of the following sizes to be laid in existing RCC/Hume/DWC/ Metal pipe. (As per Complete Item No. 23 of the DNIT). |
| 45 | Size 70 Sq.mm 3.5 Core XLPE Al. Arm. Cond. Cable |
| 46 | Supply and laying of XLPE insulated PVC sheathed Aluminium conductor cable of 1.1 KV grade as per IS 7098 (Part-I) 1988 (amended up to date) of the following sizes to be laid direct on surface with the help of M.S. clamp of suitable thickness. (As per Complete Item No. 24 of the DNIT). |
| 47 | Size 10 Sq.mm 2 Core XLPE Al. Arm. Cond. Cable |
| 48 | Size 70 Sq.mm 3.5 Core XLPE Al. Arm. Cond. Cable |
| 49 | Supply & erection of Exhaust Fan (heavy duty motor with copper wound metallic body) following size complete with motor, metallic blades, double ball bearing with minimum power consumption, (As per Complete Item No. 25 of the DNIT). |
| 50 | Size 12” Sweep 900 RPM with louver of Havells make Turbo Force SP / Orient make Industrial Heavy Duty / Crompton make EXHD 380-6-1/ Bajaj make Supreme PLUS/ Usha make Turbo HDEF only. |
| 51 | Supply and fixing of 12 modules (200 mm x 150 mm) G.I box suitable for accommodate the following accessories along with modular base and cover plate for modular switches in recess / surface etc as required for Computer Point with 4 Nos. 5/6 Amp.(As per Complete Item No. 26 of the DNIT). |
| 52 | DSR item No.2.2 Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, Ics=100% Icu and Operational Voltage 690V etc. as required. |
| 53 | 100A,30KA,FPMCCB |
| 54 | 125A,30KA,FPMCCB |
| 55 | Supply & Erection of 3 mm thick white glazed bakelite sheet on existing M.S. box. The job includes the cost of sheet and making holes & cutting and fixing with screws as required to complete the job. The Bakelite sheet should be of make Super Hylam / Formica / GreenLam make only. |
| 56 | Supply & erection of Adopter box of suitable size required made out of 16GMS sheet The box to be provided with front detachable cover and having holes of out going/ incoming pipe/ cable/ wire/ pipe. (As per Complete Item No. 29 of the DNIT). |
| 57 | Supply and erection of 14 GMS sheet frame of suitable size for erection of exhaust fan. The hole should be suitable required size for exhaust fan shall be cut from the Centre of the sheet duly fixed on existing M.S. glazing/ ventilator. (As per Complete Item No. 30 of the DNIT). |
| 58 | Suitable for 12” / 15” / 18” Exhaust Fan. |
| 59 | Supply & erection of Cabin Fan 16” sweep (metal body) oscillating type complete with aluminium blades & regulator. The fan should have regulator switch for speed regulation. (As per Complete Item No. 31 of the DNIT). |
| 60 | S/E of Thermo Plastic cable Jn. Box IP65 made out of polycarbonate with glass fibre reinforced of size 210x155x90 mm with 4 Nos. OEM made connector/ terminal blocks. (As per Complete Item No. 32 of the DNIT). Please Enable Macros to View BoQ information |