| Sl. No. | Item Description |
| 1 | REPLACEMENT OF CABLE TRAYS IN ONGC URAN PLANT |
| 2 | TOTAL LUMP SUM PRICE FOR THE COMPLETE SCOPE OF WORK OF THE TENDER (i.e. D-E) (Bidder tofill in sheet named 'price break up') OIL AND NATURAL GAS CORPORATION LTD. Project: REPLACEMENT OF CABLE TRAYS IN ONGC URAN PLANT APPENDIX A-3, Proforma for Price Schedule INDIAN BIDDERS Tender No. : ZV8SC26003 Note 1: Only Yellow Coloured Cells to be filled. Note 2: Please fill this sheets very carefully and upload as per this price format. Note 3: Please refer general notes below. Name of Bidder : Bid Reference No. I LUMP SUM PRICE Sl. no. Items Currency-1 INR A LUMP SUM PRICE for material & services for the entire scope of work for \\"REPLACEMENT OF CABLE TRAYS IN ONGC URAN PLANT . (The detailed scope of work has been provided in Technical Bid package). (i.e. Sum of A-1 to A-2) 0.0 A-1 LUMP SUM PRICE for material and services for REPLACEMENT OF CABLE TRAYS IN ONGC URAN PLANT as per Scope of Work. A-2 LUMP SUM PRICE for all other material & services (excluding A-1 above) required for completion of entire scope of work. This shall be inclusive of other services along with accessories. B Insurance for LSTK Portion in compliance of clause 7.3 of the GCC (i.e. Sum of B-1 to B-6 below) 0.0 B-1 Contractor’s All Risk Insurance/ Erection all risks/ Storage cum erection Insurance (including Offshore and Onshore Terrorism cover) B-2 Cargo Transit Insurance B-3 Third Party Liability Insurance B-4 Motor Vehicles Package Policy which included Third Party Liability Insurance B-5 Workmen’s Compensation Insurance / Employer’s Liability Insurance B-6 Contractor's Constructional Plant and Equipment Insurance C IGST/ CGST & SGST/ UTGST as applicable D Lump Sum Price for the Suplly, Installation and Commissioing as per SOW (A+B+C) 0.0 E (-) LUMP SUM PRICE for scrap for the entire scope of work for \\"REPLACEMENT OF CABLE TRAYS IN ONGC URAN PLANT (Without GST( (Receivable to ONGC) (GST shall be paid by Contractor) F TOTAL LUMP SUM PRICE FOR THE COMPLETE SCOPE OF WORK OF THE TENDER (i.e. D-E) 0.0 1. Evaluation of bids:-The Total Lumpsum price as quoted by the bidder the ‘Price Bid format’ in Appendix-A-3, after dedcuting Scarp/Debries will be the basis for price evaluation. The bidder should quote lumpsum price net of scrap value of material, and other items inclusive of all taxes, duties, levies, insurance etc., payable on material & services including transportation, insurance and loading-unloading charges up to the worksite etc. applicable for complete scope of work.2. EVALUATION CRITERIAThe total cost for evaluation purpose shall be computed deducting the receivable (without GST) due to scrap as under Total Cost = (A+B+C)-E = D-E Note |
| 3 | Payment shall be made as per Milestone Payment Formula for the respective works. General Notes: |
| 4 | Cost of material shall include cost of the materials/ equipments etc. required to be incorporated in the works, aids for fabrication, transportation and installation, cost of spares and any special tools & tackles required for pre commissioning, lubricants, chemicals and consumables for testing/ pre-commissioning and the cost of consumables for startup/ commissioning as well as for duration of operation as per details given in bidding documents. |
| 5 | Bidders to ascertain themselves all the applicable taxes & duties and include in their offer all such taxes and duties as applicable & quoted, which shall be considered for the purpose of evaluation. Bidders also to indicate ONLY such taxes & duties in relation to this contract, which the bidder is liable to pay directly to Indian Tax authorities separately in the price format at I-C. Reimbursement of IGST, CGST, SGST, UTGST etc. (which bidder is required to pay directly to Indian Tax Authorities) would, however, be made at actuals in Indian Rupees upon submission of documentary proof of duty assessment & payment (through deposit or through credit) thereof and would further be limited to the amount indicated in price schedule, whichever is less. No reimbursement shall be made to the bidder for Custom Duty, IGST, CGST, SGST, UTGST etc., paid by bidders to their Sub Contractor, Vendors, Agents etc. Change in law is not applicable against such taxes & duties (i.e. Custom Duty, IGST,SGST,CGST,UTGST etc.) paid by bidders to their Sub Contractor, Vendors, Agents etc. |
| 6 | The above costs i.e. total lump sum price are all inclusive costs for providing the material & services as per the requirements contained in the Bidding Documents read with subsequent amendments/addendum /corrigendum /clarifications conveyed to the bidder.Bidder to note that price quoted at sl. no. F above i.e. TOTAL LUMSUM PRICE for complete scope of work of the tender (i.e.A+B+C)-(E) shall be considered for ascertaining the ranking of bidders. |
| 7 | TDS as applicable under statute, will be deducted |
| 8 | Bidders shall submit copy of Price Proforma (APPENDIX-A3) in the unpriced (techno-commercial bid filled as 'x' and/or 'X' marks at places where bidder has quoted in original sealed priced bid Proforma as a confirmation that he has quoted against that particular item. For all the cells marked 'x' and 'X' in the Proforma Schedule (APPENDIX-A3) of Prices in the unpriced (techno-contractual) bid. Bidders shall click on the individual cell and select from the drop down list for confirmation that he has Quoted / Not Quoted against that particular item. For other cells e.g. Custom Duties, Change in Law etc. (wherever drop down option is not provided), fill the relevant information. |
| 9 | Bidders to consider various Custom & GST exemptions/Concessional rate available for eligible PEL/ML areas as well as different facilities covered under the project . |
| 10 | In cases where Contractors contends that their Corporate Policies with worldwide coverage meets the insurance requirements of the contract in respect of Policies from B-1 to B-6 under item B above, Contractor needs to ensure that all the conditions mentioned in the contract in respect of insurance are complied with. Any other policy not mentioned above but required to be taken on the basis of specific nature of contract, as mentioned in the contract should also be included in the Total Insurance cost. |
| 11 | The bidder shall refer to the Scope of Work (Vol-II) and other relevant volumes of the tender documents for complete technical and execution requirements. |
| 12 | As per GCC Clause 19.0, a joint statement shall be signed by ONGC and the Contractor at intervals of six months.In case of delays attributable to the Contractor, provisional LD amounts shall be withheld from invoices pending final delay analysis.For LD computation under GCC Clauses 6.3.2 and 6.3.3, the proportionate value of completed and accepted works shall be used for determining the LD amount to be withheld.Formula:P = Total number of all segments/facilities under the projectQ = Total number of segments/facilities completed, commissioned, and accepted/handed overProportionate Value = (Lump-Sum Price at F × Q) / P Name of Authorised Signatory: Designation: Place and Date: II Unit Adjustment Rate I UNIT ADJUSTMENT RATE (For Basis of Adjustment) - REPLACEMENT OF CABLE TRAYS IN ONGC URAN PLANT Scope Quantity--> Unit Rate Currency1/Unit (Without GST) Total (i) Unit rate for Ladder type cable tray (in Mtrs.) 0.0 Cable Ladder & accessories shall be made up of material FRP straight sections shall be provided in standard lengths of 3m. Loading capacity of tray shall be as per NEMA FG 1 1993. 0.0 a 150mm (W)×100mm (H) Ladder Type Cable Tray 526.0 0.0 b 300mm (W)×100mm (H) Ladder Type Cable Tray 1468.0 0.0 c 450mm (W)×100mm (H) Ladder Type Cable Tray 1955.0 0.0 d 600mm (W)×100mm (H) Ladder Type Cable Tray 302.0 0.0 e 750mm (W)×100mm (H) Ladder Type Cable Tray 4457.0 0.0 f 900mm (W)×100mm (H) Ladder Type Cable Tray 623.0 0.0 g 1000mm (W)×100mm (H) Ladder Type Cable Tray 1836.0 0.0 (ii) Unit rate for 90° Horizontal Bends of material FRP, suitable for the following Ladder type cable tray sizes (in Nos.) 0.0 150mm (W)×100mm (H) - Ladder Type - (90° Bend) - R=600mm 23.0 0.0 300mm (W)×100mm (H) - Ladder Type - (90° Bend) - R=600mm 47.0 0.0 450mm (W)×100mm (H) - Ladder Type - (90° Bend) - R=600mm 20.0 0.0 450mm (W)×100mm (H) - Ladder Type - (90° Bend) - R=900mm 11.0 0.0 600mm (W)×100mm (H) - Ladder Type - (90° Bend) - R=900mm 1.0 0.0 750mm (W)×100mm (H) - Ladder Type - (90° Bend) - R=900mm 47.0 0.0 900mm (W)×100mm (H) - Ladder Type - (90° Bend) - R=900mm 5.0 0.0 (iii) Unit rate for 60° Horizontal Bends of material FRP, suitable for the following Ladder type cable tray sizes (in Nos.) 0.0 150mm (W)×100mm (H) - Ladder Type - (60° Bend) - R=600mm 2.0 0.0 300mm (W)×100mms (H) - Ladder Type - (60° Bend) - R=600mm 20.0 0.0 450mm (W)×100mm (H) - Ladder Type - (60° Bend) - R=600mm 2.0 0.0 600mm (W)×100mm (H) - Ladder Type - (60° Bend) - R=600mm 2.0 0.0 750mm (W)×100mm (H) - Ladder Type - (60° Bend) - R=900mm 2.0 0.0 (iv) Unit rate for 45° Horizontal Bends of material FRP, suitable for the following Ladder type cable tray sizes (in Nos.) 0.0 300mm (W)×100mm (H) - Ladder Type - (45° Bend) - R=600mm 12.0 0.0 450mm (W)×100mm (H) - Ladder Type - (45° Bend) - R=600mm 6.0 0.0 450mm (W)×100mm (H) - Ladder Type - (45° Bend) - R=900mm 12.0 0.0 750mm (W)×100mm (H) - Ladder Type - (45° Bend) - R=900mm 22.0 0.0 900mm (W)×100mm (H) - Ladder Type - (45° Bend) - R=900mm 2.0 0.0 (v) Unit rate for 30° Horizontal Bends of material FRP, suitable for the following Ladder type cable tray sizes(in Nos.) 0.0 300mm (W)×100mm (H) - Ladder Type - (30° Bend) - R=600mm 47.0 0.0 450mm (W)×100mm (H) - Ladder Type - (30° Bend) - R=900mm 7.0 0.0 (vi) Unit rate for 90° Vertical Inside Bends of material FRP, suitable for thefollowing Ladder type cable tray sizes (in nos). 0.0 150mm (W)×100mm (H) - Ladder Type - (90° Bend) - R=600mm 8.0 0.0 300mm (W)×100mm (H) - Ladder Type - (90° Bend) - R=600mm 48.0 0.0 450mm (W)×100mm (H) - Ladder Type - (90° Bend) - R=600mm 55.0 0.0 600mm (W)×100mm (H) - Ladder Type - (90° Bend) - R=600mm 5.0 0.0 750mm (W)×100mm (H) - Ladder Type - (90° Bend) - R=900mm 54.0 0.0 900mm (W)×100mm (H) - Ladder Type - (90° Bend) - R=900mm 7.0 0.0 (vii) Unit rate for 60° Vertical Inside Bends of material FRP, suitable for the following Ladder type cable tray sizes (in nos). 0.0 150mm (W)×100mm (H) - Ladder Type - (60° Bend) - R=600mm 6.0 0.0 450mm (W)×100mm (H) - Ladder Type - (60° Bend) - R=600mm 6.0 0.0 750mm (W)×100mm (H) - Ladder Type - (60° Bend) - R=600mm 4.0 0.0 (viii) Unit rate for 45° Vertical Inside Bends of material FRP, suitable for the following Ladder type cable tray sizes (in nos). 0.0 450mm (W)×100mm (H) - Ladder Type - (45° Bend) - R=600mm Nos. 19 19.0 0.0 600mm (W)×100mm (H) - Ladder Type - (45° Bend) - R=600mm Nos. 1 1.0 0.0 750mm (W)×100mm (H) - Ladder Type - (45° Bend) - R=900mm Nos. 14 14.0 0.0 (ix) Unit rate for 30° Vertical Inside Bends of material FRP, suitable for the following Ladder type cable tray sizes (in nos). 0.0 300mm (W)×100mm (H) - Ladder Type - (30° Bend) - R=600mm 19.0 0.0 450mm (W)×100mm (H) - Ladder Type - (30° Bend) - R=600mm 13.0 0.0 750mm (W)×100mm (H) - Ladder Type - (30° Bend) - R=900mm 13.0 0.0 (x) Unit rate for 90° Vertical Outside Bends of material FRP, suitable for the following Ladder type cable tray sizes(in nos). 0.0 150mm (W)×100mm (H) - Ladder Type - (90° Bend) - R=600mm 16.0 0.0 300mm (W)×100mm (H) - Ladder Type - (90° Bend) - R=600mm 50.0 0.0 450mm (W)×100mm (H) - Ladder Type - (90° Bend) - R=600mm 66.0 0.0 600mm (W)×100mm (H) - Ladder Type - (90° Bend) - R=600mm 5.0 0.0 750mm (W)×100mm (H) - Ladder Type - (90° Bend) - R=900mm 48.0 0.0 900mm (W)×100mm (H) - Ladder Type - (90° Bend) - R=900mm 2.0 0.0 (xi) 60° Vertical Outside Bends of material FRP, suitable for the following Ladder type cable tray sizes(in nos.) 0.0 450mm (W)×100mm (H) - Ladder Type - (60° Bend) - R=600mm 6.0 0.0 (xii) 45° Vertical Outside Bends of material FRP, suitable for the following Ladder type cable tray sizes(in nos.) 0.0 300mm (W)×100mm (H) - Ladder Type - (45° Bend) - R=600mm 4.0 0.0 450mm (W)×100mm (H) - Ladder Type - (45° Bend) - R=600mm 20.0 0.0 600mm (W)×100mm (H) - Ladder Type - (45° Bend) - R=600mm 1.0 0.0 750mm (W)×100mm (H) - Ladder Type - (45° Bend) - R=900mm 24.0 0.0 900mm (W)×100mm (H) - Ladder Type - (45° Bend) - R=900mm 2.0 0.0 (xiii) 30° Vertical Outside Bends of material FRP, suitable for the following Ladder type cable tray sizes(in nos.) 0.0 300mm (W)×100mm (H) - Ladder Type - (30° Bend) - R=600mm 14.0 0.0 450mm (W)×100mm (H) - Ladder Type - (30° Bend) - R=600mm 4.0 0.0 750mm (W)×100mm (H) - Ladder Type - (30° Bend) - R=900mm 11.0 0.0 (xiv) Vertical Adjuster of material FRP, suitable for the following Ladder type cable tray sizes(in nos.) 0.0 750mm(W) × 100mm(H) - Ladder type (2×Vertical Adjuster) 4.0 0.0 (xv) CONCENTRIC Reducer of material FRP, suitable for the following Ladder type cable tray sizes(in nos.) 0.0 300 mm (W)×150 mm (W)×100 mm (H) - Ladder type (CONCENTRIC REDUCER) 1.0 0.0 450 mm (W)×300 mm (W)×100 mm (H) - Ladder type (CONCENTRIC REDUCER) 5.0 0.0 750 mm (W)×450 mm (W)×100 mm (H) - Ladder type (CONCENTRIC REDUCER) 1.0 0.0 900 mm(W)×750 mm (W)×100 mm (H) - Ladder type (CONCENTRIC REDUCER) 1.0 0.0 900 mm(W)×450 mm (W)×100 mm (H) - Ladder type (CONCENTRIC REDUCER) 2.0 0.0 (xvi) EQUAL TEES of material FRP, suitable for the following Ladder type cable tray sizes(in nos.) 0.0 450 mm(W)×100 mm(H) - Ladder type R=300mm 2.0 0.0 750 mm(W)×100 mm(H) - Ladder type R=600mm 4.0 0.0 900 mm(W)×100 mm(H) - Ladder type R=600mm 1.0 0.0 (xviii) UNEQUAL TEES of material FRP, suitable for the following Ladder type cable tray sizes(in nos.) 0.0 150 mm(W1) × 150 mm(W2) x 450(W3) x 100 mm(H) - Ladder type R=300mm 1.0 0.0 450 mm(W1) × 450 mm(W2) x 300(W3) x 100 mm(H) - Ladder type R=300mm 0.0 0.0 600 mm(W1) × 600 mm(W2) x 450(W3) x 100 mm(H) - Ladder type R=300mm 1.0 0.0 900 mm(W1) × 900 mm(W2) x 450(W3) x 100 mm(H) - Ladder type R=300 2.0 0.0 900 mm(W1) × 900 mm(W2) x 300(W3) x 100 mm(H) - Ladder type R=300mm 1.0 0.0 (xix) PEFRORATED TYPE CABLE TRAY(in mtrs.) 0.0 Cable tray & accessories shall be made up of material FRP straight sections shall be provided in standard lengths of 3m. Loading capacity of tray shall be as per NEMA FG 1 1993. 148.0 0.0 100mm (W)×50mm (H) Perforated Type Cable Tray 568.0 0.0 150mm (W)×50mm (H) Perforated Type Cable Tray 680.0 0.0 200mm (W)×50mm (H) Perforated Type Cable Tray 409.0 0.0 300mm (W)×100mm (H) Perforated Type Cable Tray 486.0 0.0 (xx) Horizontal Bends of material FRP, suitable for the following Perforated type of cable tray sizes(in nos.) 0.0 50mm (W)× 50mm (H) - Perforated type - (90° Elbow) - R=300mm 2.0 0.0 100mm (W)× 50mm (H) - Perforated type - (30° Elbow) - R=300mm 1.0 0.0 100mm (W)× 50mm (H) - Perforated type - (90° Elbow) - R=300mm 18.0 0.0 150mm (W)× 50mm (H) - Perforated type - (45° Elbow) - R=300mm 2.0 0.0 150mm (W)× 50mm (H) - Perforated type - (60° Elbow) - R=300mm 5.0 0.0 150mm (W)× 50mm (H) - Perforated type - (90° Elbow) - R=300mm 24.0 0.0 200mm (W)× 50mm (H) - Perforated type - (90° Elbow) - R=300mm 16.0 0.0 300mm (W)× 100mm (H) - Perforated type - (30° Elbow) - R=300mm 19.0 0.0 300mm (W)× 100mm (H) - Perforated type - (45° Elbow) - R=300mm 2.0 0.0 300mm (W)× 100mm (H) - Perforated type - (60° Elbow) - R=300mm 2.0 0.0 300mm (W)× 100mm (H) - Perforated type - (90° Elbow) - R=300mm 20.0 0.0 (xxi) Vertical Inside Angle Flexi Riser of material FRP, suitable for the following Perforated type of cable tray sizes(in nos.) 0.0 100mm (W)× 50mm (H) Perforated Type (90° Bend) - R=300mm 8.0 0.0 100mm (W)× 50mm (H) Perforated Type (60° Bend) - R=300mm 2.0 0.0 150mm (W)× 50mm (H) Perforated Type (30° Bend) - R=300mm 2.0 0.0 150mm (W)× 50mm (H) Perforated Type (45° Bend) - R=300mm 4.0 0.0 150mm (W)× 50mm (H) Perforated Type (90° Bend) - R=300mm 19.0 0.0 200mm (W)× 50mm (H) Perforated Type (45° Bend) - R=300mm 1.0 0.0 200mm (W)× 50mm (H) Perforated Type (90° Bend) - R=300mm 11.0 0.0 300mm (W)× 100mm (H) Perforated Type (30° Bend) - R=300mm 1.0 0.0 300mm (W)× 100mm (H) Perforated Type (45° Bend) - R=300mm 1.0 0.0 300mm (W)× 100mm (H) Perforated Type (60° Bend) - R=300mm 5.0 0.0 300mm (W)× 100mm (H) Perforated Type (90° Bend) - R=300mm 11.0 0.0 (xxii) Vertical Outside Angle Flexi Riser of material FRP, suitable for the following Perforated type of cable tray sizes(in nos.) 0.0 100mm (W)× 50mm (H) Perforated Type (30° Bend) - R=300mm 2.0 0.0 100mm (W)× 50mm (H) Perforated Type (60° Bend) - R=300mm 2.0 0.0 100mm (W)× 50mm (H) Perforated Type (90° Bend) - R=300mm 16.0 0.0 150mm (W)× 50mm (H) Perforated Type (30° Bend) - R=300mm 2.0 0.0 150mm (W)× 50mm (H) Perforated Type (45° Bend) - R=300mm 10.0 0.0 150mm (W)× 50mm (H) Perforated Type (90° Bend) - R=300mm 24.0 0.0 200mm (W)× 50mm (H) Perforated Type (45° Bend) - R=300mm 1.0 0.0 200mm (W)× 50mm (H) Perforated Type (90° Bend) - R=300mm 18.0 0.0 300mm (W)× 100mm (H) Perforated Type (60° Bend) - R=300mm 5.0 0.0 300mm (W)× 100mm (H) Perforated Type (90° Bend) - R=300mm 19.0 0.0 AA1 Summation of amount with respective Quantities and Currency-1 in Unit Adjustment rate table at (i), (ii), (iii), (iv), (v) to xxii 0.0 II UNIT ADJUSTMENT RATE (For Basis of Adjustment) -Replacement of Cable trays Scope Quantity--> Unit Rate Currency1/Unit (Without GST) Total INSTRUMENTATION BILL OF QUANTITY Cable tray shall be made up of FRP material. Cable Tray shall withstand a load of minimum 7.4 to maximum of 120Kg/ m with a support of every 1.5m. All associated cable tray fittings shall be of the same manufacturing characteristics as the straight sections. 0.0 (xxiii) Tray Size :50mmx50mm (Perforated Type) 50mm width x 50mm depth Straight- Perforated Type Mtrs 2139.0 0.0 50mm width x 50mm depth Horizontal Bend 30 Deg Radius- Perforated type 2.0 0.0 50mm width x 50mm depth Horizontal Bend 45 Deg Radius- Perforated type 81.0 0.0 50mm width x 50mm depth Horizontal Bend 90 Deg Radius- Perforated type 363.0 0.0 50mm width x 50mm depth Inside Raiser 30 Deg Radius- Perforated Type Nos 9.0 0.0 50mm width x 50mm depth Inside Raiser 45 Deg Radius- Perforated Type Nos 89.0 0.0 50mm width x 50mm depth Inside Raiser 90 Deg Radius- Perforated Type Nos 155.0 0.0 50mm width x 50mm depth outside Raiser 30 Deg Radius- Perforated Type Nos 6.0 0.0 50mm width x 50mm depth outside Raiser 45 Deg Radius- Perforated Type Nos 88.0 0.0 50mm width x 50mm depth outside Raiser 90 Deg Radius- Perforated Type Nos 165.0 0.0 Tee Joint (50mm x 50mm) Nos 2.0 0.0 (xxiv) Tray Size :100mmx50mm (Perforated Type) 0.0 100mm width x 50mm depth Straight- Perforated Type Mtrs 3845.0 0.0 100mm width x 50mm depth Horizontal Bend 30 Deg Radius- Perforated type 4.0 0.0 100mm width x 50mm depth Horizontal Bend 45 Deg Radius- Perforated type 147.0 0.0 100mm width x 50mm depth Horizontal Bend 90 Deg Radius- Perforated type 418.0 0.0 100mm width x 50mm depth Inside Raiser 30 Deg Radius- Perforated Type Nos 10.0 0.0 100mm width x 50mm depth Inside Raiser 45 Deg Radius- Perforated Type Nos 100.0 0.0 100mm width x 50mm depth Inside Raiser 60 Deg Radius- Perforated Type Nos 3.0 0.0 100mm width x 50mm depth Inside Raiser 90 Deg Radius- Perforated Type Nos 203.0 0.0 100mm width x 50mm depth outside Raiser 30 Deg Radius- Perforated type 14.0 0.0 100mm width x 50mm depth outside Raiser 45 Deg Radius- Perforated type 98.0 0.0 100mm width x 50mm depth outside Raiser 60 Deg Radius- Perforated type 3.0 0.0 100mm width x 50mm depth outside Raiser 90 Deg Radius- Perforated type 214.0 0.0 Tee Joint (150mm x 50mm) Nos 2.0 0.0 Tee Joint (100mm x 100mm) Nos 6.0 0.0 Tee Joint (200mm x 100mm) Nos 2.0 0.0 Reducer (100mm x 50mm) Nos 16.0 0.0 Reducer (100mm x 200mm) Nos 2.0 0.0 (xxv) Tray Size :150mmx100mm (Perforated Type) 0.0 150mm width x 100mm depth Straight- Perforated Type Mtrs 88.0 0.0 150mm width x 100mm depth Horizontal Bend 45 Deg Radius- Perforated type 5.0 0.0 150mm width x 100mm depth Horizontal Bend 90 Deg Radius- Perforated type 35.0 0.0 150mm width x 100mm depth Inside Raiser 90 Deg Radius- Perforated type 6.0 0.0 150mm width x 100mm depth outside Raiser 90 Deg Radius- Perforated type 9.0 0.0 Reducer (150mm x 50mm) - Perforated Type Nos 2.0 0.0 (xxvi) Tray Size :150mm x 50mm (Perforated Type) 0.0 150mm width x 50mm depth Straight- Perforated Type Mtrs 36.0 0.0 150mm width x 50mm depth Horizontal Bend 90 Deg Radius- Perforated type 12.0 0.0 150mm width x 50mm depth Inside Raiser 90 Deg Radius- Perforated Type Nos 5.0 0.0 150mm width x 50mm depth outside Raiser 90 Deg Radius- Perforated type 4.0 0.0 (xxvii) Tray Size :200mmx100mm (Perforated Type) 0.0 200mm width x 100mm depth Straight- Perforated Type Mtrs 2332.0 0.0 200mm width x 100mm depth Horizontal Bend 45 Deg Radius- Perforated type 113.0 0.0 200mm width x 100mm depth Horizontal Bend 90 Deg Radius- Perforated type 572.0 0.0 200mm width x 100mm depth Inside Raiser 30 Deg Radius- Perforated type 6.0 0.0 200mm width x 100mm depth Inside Raiser 45 Deg Radius- Perforated type 58.0 0.0 200mm width x 100mm depth Inside Raiser 90 Deg Radius- Perforated type 104.0 0.0 200mm width x 100mm depth outside Raiser 30 Deg Radius- Perforated type 10.0 0.0 200mm width x 100mm depth outside Raiser 45 Deg Radius- Perforated type 53.0 0.0 200mm width x 100mm depth outside Raiser 90 Deg Radius- Perforated type 141.0 0.0 Tee Joint (200mm x 100mm) Nos 2.0 0.0 Tee Joint (200mm x 200mm) Nos 2.0 0.0 Reducer (200mm x 50mm) Nos 3.0 0.0 Reducer (200mm x 100mm) Nos 22.0 0.0 Reducer (200mm x 300mm) Nos 4.0 0.0 (xxviii) Tray Size :300mmx100mm (Perforated Type) 0.0 300mm width x 100mm depth Straight- Perforated Type Mtrs 83.0 0.0 300mm width x 100mm depth Horizontal Bend 90 Deg Radius- Perforated type 6.0 0.0 300mm width x 100mm depth Inside Raiser 45 Deg Radius- Perforated type 9.0 0.0 300mm width x 100mm depth Inside Raiser 90 Deg Radius- Perforated type 6.0 0.0 300mm width x 100mm depth outside Raiser 45 Deg Radius- Perforated type 8.0 0.0 300mm width x 100mm depth outside Raiser 90 Deg Radius- Perforated type 21.0 0.0 Tee Joint (300mm x 300mm) Nos 2.0 0.0 (xxix) Tray Size :300mmx150mm (Ladder Type) 0.0 300mm width x 150mm depth Straight- Ladder Type Mtrs 323.0 0.0 300mm width x 150mm depth Horizontal Bend 45 Deg Radius- Ladder type 6.0 0.0 300mm width x 150mm depth Horizontal Bend 90 Deg Radius- Ladder type 21.0 0.0 300mm width x 150mm depth Inside Raiser 45 Deg Radius- Ladder Type Nos 10.0 0.0 300mm width x 150mm depth Inside Raiser 90 Deg Radius- Ladder Type Nos 11.0 0.0 300mm width x 150mm depth outside Raiser 45 Deg Radius- Ladder Type Nos 9.0 0.0 300mm width x 150mm depth outside Raiser 90 Deg Radius- Ladder Type Nos 14.0 0.0 (xxx) Tray Size :300mmx150mm (Perforated Type) 0.0 300mm width x 150mm depth Straight- Perforated Type Mtrs 1844.0 0.0 300mm width x 150mm depth Horizontal Bend 30 Deg Radius- Perforated type 6.0 0.0 300mm width x 150mm depth Horizontal Bend 45 Deg Radius- Perforated type 132.0 0.0 300mm width x 150mm depth Horizontal Bend 60 Deg Radius- Perforated type 2.0 0.0 300mm width x 150mm depth Horizontal Bend 90 Deg Radius- Perforated type 135.0 0.0 300mm width x 150mm depth Inside Raiser 30 Deg Radius- Perforated type 15.0 0.0 300mm width x 150mm depth Inside Raiser 45 Deg Radius- Perforated type 62.0 0.0 300mm width x 150mm depth Inside Raiser 60 Deg Radius- Perforated type 2.0 0.0 300mm width x 150mm depth Inside Raiser 90 Deg Radius- Perforated type 40.0 0.0 300mm width x 150mm depth outside Raiser 30 Deg Radius- Perforated type 14.0 0.0 300mm width x 150mm depth outside Raiser 45 Deg Radius- Perforated type 50.0 0.0 300mm width x 150mm depth outside Raiser 60 Deg Radius- Perforated type 3.0 0.0 300mm width x 150mm depth outside Raiser 90 Deg Radius- Perforated type 90.0 0.0 Tee Joint (300mm x 300mm) Nos 4.0 0.0 Reducer (300mm x 100mm) Nos 6.0 0.0 Reducer (300mm x 200mm) Nos 18.0 0.0 (xxxi) Tray Size :450mmx150mm (Perforated Type) 0.0 450mm width x 150mm depth Straight- Perforated Type Mtrs 978.0 0.0 450mm width x 150mm depth Horizontal Bend 45 Deg Radius- Perforated type 46.0 0.0 450mm width x 150mm depth Horizontal Bend 90 Deg Radius- Perforated type 41.0 0.0 450mm width x 150mm depth Inside Raiser 30 Deg Radius- Perforated type 5.0 0.0 450mm width x 150mm depth Inside Raiser 45 Deg Radius- Perforated type 30.0 0.0 450mm width x 150mm depth Inside Raiser 90 Deg Radius- Perforated type 22.0 0.0 450mm width x 150mm depth outside Raiser 30 Deg Radius- Perforated type 5.0 0.0 450mm width x 150mm depth outside Raiser 45 Deg Radius- Perforated type 28.0 0.0 450mm width x 150mm depth outside Raiser 90 Deg Radius- Perforated type 28.0 0.0 Tee Joint (450mm x 300mm) Nos 6.0 0.0 Reducer (450mm x 200mm) Nos 4.0 0.0 Reducer (450mm x 300mm) Nos 21.0 0.0 (xxxii) Tray Size :450mmx150mm (Ladder Type) 0.0 450mm width x 150mm depth Straight- Ladder Type Mtrs 60.0 0.0 450mm width x 150mm depth Inside Raiser 90 Deg Radius- Ladder Type Nos 2.0 0.0 450mm width x 150mm depth outside Raiser 90 Deg Radius- Ladder Type Nos 2.0 0.0 (xxxiv) Tray Size :600mmx150mm (Ladder Type) 0.0 600mm width x 150mm depth Straight- Ladder Type Mtrs 15.0 0.0 (xxxv) Tray Size :600mmx150mm (Perforated Type) 0.0 600mm width x 150mm depth Straight- Perforated Type Mtrs 184.0 0.0 600mm width x 150mm depth Horizontal Bend 90 Deg Radius- Perforated type 17.0 0.0 600mm width x 150mm depth Inside Raiser 30 Deg Radius- Perforated type 2.0 0.0 600mm width x 150mm depth Inside Raiser 45 Deg Radius- Perforated type 3.0 0.0 600mm width x 150mm depth Inside Raiser 60 Deg Radius- Perforated type 2.0 0.0 600mm width x 150mm depth Inside Raiser 90 Deg Radius- Perforated type 4.0 0.0 600mm width x 150mm depth outside Raiser 30 Deg Radius- Perforated type 2.0 0.0 600mm width x 150mm depth outside Raiser 45 Deg Radius- Perforated type 4.0 0.0 600mm width x 150mm depth outside Raiser 60 Deg Radius- Perforated type 2.0 0.0 600mm width x 150mm depth outside Raiser 90 Deg Radius- Perforated type 4.0 0.0 Reducer (600mm x 300mm) Nos 3.0 0.0 (xxxvi) Tray Size :1200mmx150mm (Ladder Type) 0.0 1200mm width x 150mm depth Straight- Ladder Type Mtrs 528.0 0.0 (xxxvii) Tray Size :600mmx150mm (Ladder Type) 0.0 600mm width x 150mm depth Straight- Ladder Type Mtrs 216.0 0.0 (xxxviii) Tray Size :750mmx150mm (Ladder Type) 0.0 750mm width x 150mm depth Straight- Ladder Type Mtrs 252.0 0.0 AA2 Summation of amount with respective Quantities and Currency-1 in Unit Adjustment rate table at xxiii to xxxviii 0.0 AA3 Grand Summation of amount with respective Quantities and Currency-1 in Unit Adjustment rate table from (i+ii+ to xxxviii) i.e. (AA1 + AA2)of Replacement of electrical and instruments cable trays 0.0 AA4 Whether the Summation of amount in Unit Adjustment Rate table at AA3 is EQUAL TO the Quotation at Sr. No. A-1 in the Price Schedule Sheet-I Lumpsum (As also brought out at AA3 above) YES Notes: |
| 13 | The sum of unit rates X quantity indicated above at AA3 should match with quoted lumpsum cost at A-1 |
| 14 | The Contract Price shall be adjusted upward or downwards as applicable on the basis of As-built / As laid quantities by the respective unit adjustment rates indicated by bidder in above table in case of any increase or decrease in estimated quantities as mentioned in Table-II above. |
| 15 | The above all inclusive unit adjustment rates are inclusive of survey, design, engineering, material, transportation, installation/laying, burial, backfilling, testing, pre-commissioning, post installation survey and commissioning etc. Payment for any increase/decrease in quantity as compared to estimated quantity will be made at this unit rates. There shall be no further extra cost to any account. The payment / adjustment of taxes if any on variations in quantities wherever applicable shall be made as per tariff mentioned in sheet-V of price schedule, titled as \\"Change in Law & Regulations\\". |
| 16 | Bidders can insert separate columns in case of quoting multiple currencies. III Cost Reimbursable Additional Items : Cost Plus Percentage |
| 17 | Percentage fee applicable to cost of material used for extra work items. |
| 18 | Percentage fee applicable to equipment subcontracts for extra work |
| 19 | Percentage fee applicable to labour subcontracts for extra work |
| 20 | Percentage fee applicable to one year’s spares Notes: |
| 21 | The above percentage will also be used by the Company to order bought-out items and extra equipment not included in the Bidding Documents. |
| 22 | In respect of item 4 the cost shall be reimbursed as per provision of clause 5.16 of part II, GCC. IV Customs duty: Deleted V Change In Laws and Regulations: Laws, Acts, Rules, Regulations etc. and the tariffs thereof considered by the Bidder while estimating the incidence of taxes, duties, fees, charges, levies etc. included in the bidder’s lump sum prices for the Works (as quoted in the Appendix A-3, I through V) as per relevant provisions of General Conditions of Contract to be used for the purpose of adjustment of Contract Price in the event of change of Law in terms of Clause 7.6 of General Conditions of Contract are as under: Sl. no. ITEM Bidding Documents Clause Reference Laws / Acts / Rules / regulations reference Tarif indicating rate of tax/ duty/ fee/ charge/ levy Tax Amount included in the Lump sum price (Add taxes together for all locations/ works) Remarks 1.0 2.0 3.0 4.0 5.0 |
| 23 | IGST/ CGST & SGST/ UTGST as applicable for the following: i Supply of material and services as quoted at A-1 and A-2 of Lumpsum of price Schedule. Bidder to ensure that the quoted taxes and duties, against each item, should be w.r.t the corresponding combined value of material, services & value of insurance quoted under various heads of I-Lumpsum of Price Schedu le i.e. Appendix A-3. ii Insurance as quoted at B of I-Lumpsum of price Schedule. a. Total IGST/ CGST & SGST/ UTGST (as applicable) as quoted above b. Total Quoted IGST/ CGST & SGST/ UTGST (as applicable) under item I-C of Price Schedule i.e Appendix A-3 c. Whether item a and b above are equal. Yes Note:- |
| 24 | Bidder to ensure that \\"Total IGST/ CGST & SGST/ UTGST (as applicable)\\" above must be eaual to the value quoted against I-C of Price Schedule i.e Appendix A-3. |
| 25 | Bidder may suitably add other heads/columns/rows to indicate all the provisions and related information with regard to above. Bidders are requested to go through Clause 7.6 of General Conditions of Contract carefully, while furnishing the above table. Strike out the items, which are not applicable or write `not applicable’. |
| 26 | Change in law shall not be applicable to taxes and duties in respect of subcontractors, venders etc. of contractors. |
| 27 | Bidder shall indicate the details of Laws/ Acts / Rules/ Regulations reference and tariff indicating rates of tax/ duties/ fee/ charge/ levy under Column 3 & 4 respectively in the unpriced bid also. |
| 28 | Bidders are advised to refer thoroughly scope of work (all disciplines), price impacting activities in the entire terms & conditions mentioned in the tender documents. |
| 29 | For clarity on tax clauses and change in law clauses of GCC, bidder/ contractor may note the following:a. If there is any difference in rate between quoted rate of tax and applicable rate of tax as on bid submission date, then such difference in rate will be maintained for effecting change in law, if any, in future. Without prejudice toany other remedies available to company in the contract or in Law, in case of change in laws during scheduled completion period (included extended period without levy of LD/without reserving right to levy LD), irrespective ofamount and rates of taxes quoted by successful bidder/contractor, the total quoted amount (including tax amounts) will be considered as inclusive of all applicable tax amounts which are applicable on the date of bid submissionand accordingly, difference between applicable rate of taxes on the date of bid submission and the rates of taxes applicable on the date of change in law, will be reimbursed to successful bidder/contractor by company in casesuch difference is positive and such difference will be recovered from the successful bidder/contractor by the company in case such difference is negative.b. In case the quoted tax rate/tax amount is less than the applicable tax rate/ tax amount on date of bid submission, it would be considered that the difference in the two rates/amounts is included in the amounts quoted in otherquoted line items, other than the quoted tax amount and (i) payment/reimbursement will be limited to considering the quoted tax rate or the quoted tax amount or the amount shown in proof of payment, whichever is lower and (ii)in case there is a change in law, such difference between the quoted tax rate/tax amount and the applicable tax rate/ tax amount on date of bid submission, will be subtracted from the base value (base value is the amount onwhich taxes are applied which would be derived from the total quoted/contract value inclusive of taxes) to arrive at the net base value on which effect of change in law would be applied.c. In case the quoted tax rate/tax amount is more than the applicable tax rate/ tax amount as on the date of bid submission (i) payment/reimbursement will be restricted to the lower of the two and (ii) in case there is a change inlaw, it will be treated as per Point \\"a\\" above. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |