| 1 | Excavating in post holes( or similar holes) each n exc 0.50 cum , getting out,returning filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm in soft/ loose soil complete all as specified and directed. |
| 2 | M&L for PCC 1:3:6 type C2, using 40mm graded crushed stone aggregate, as in foundation filling & mass concrete complete all as specified and directed. |
| 3 | M&L for PCC type C1,1:3:6 using 20mm graded crushed stone agg,in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for water troughs and the like including weathering, slightly rounded or chamfered angles and throating, complete all as specified and directed. |
| 4 | Supply only integral water proofing compound liquid grade conforming to IS-2645 complete all as specified and directed. |
| 5 | M&L for brickwork with old size fly ash bricks, straight or curved on plan exc 6m mean radius, built in cement mortar 1:6 complete all as specified and directed. |
| 6 | BLANK |
| 7 | M&L for brickwork with old size fly ash bricks, straight or curved on plan to any radius as in half brick thick walls, built in cement mortar 1:4 complete all as specified and directed. |
| 8 | M&L for Cutting chases, pinning in brick walls,making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills,sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring,etc.and making good, cutting not exc 10cm girth complete all as specified and directed. |
| 9 | Making good under cills or over arches, lintels and bressummers. including all pinning in cement mortar 1:4 when necessary complete all as specified and directed. |
| 10 | M&L for 18mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to matchwith shade of granite over and including 15mm thick screed bed in cement mortar 1:6 complete all as specified and directed. |
| 11 | S&F 35mm thick factory made flush shutter, solid core construction with block board core and plywood face panels, commercial type on both sides kiln seasoned and chemically pressure treated complete all as specified and directed. |
| 12 | Taking down chowkat or frame with shutter (without taking off shutter from the frame) area not exc. 1.5sqm each, including cutting holes for removing the hold fast,making good disturbed surfaces and removing materials from site of work complete all as specified and directed. |
| 13 | Taking down chowkat or frame with shutter (without taking off shutter from the frame) exc. 1.5 sqm and n.exc 4 sqm each, including cutting holes for removing the hold fast, making good disturbed surfaces and removing materials from site of work complete all as specified and directed. |
| 14 | S&F factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heatm moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain/decorative colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement in the frame at site as per specification & drawing. etc complete all as specified and directed. |
| 15 | S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube in opening as per specification & drawing complete all as specified Make : Rajshree/Sintex/H2O solution.Note:-The door frame to be fixed to wall using 8 x 100 mm long anchor fasteners. |
| 16 | S&F 200mm aluminium anodised barrel tower bolts of extruded section complete all as specified and directed. |
| 17 | S&F 150mm aluminium anodised barrel tower bolts of extruded section complete all as specified and directed. |
| 18 | S&F 300 mm long aluminium alloy, anodised,sliding door bolt with hasp,staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and direcetd. |
| 19 | S&F 150mm size aluminium handle cast type complete all as specified and directed. |
| 20 | S&F in repairs Harrison rails, mild steel, chromium plated with fixing brackets,stops, rollers etc of 25 mm bore complete all as specified and as directed |
| 21 | S&F in repair tubular towel rail 20mm dia type brass chrormium plated 600mm long between flanges complete all as specified and directed. |
| 22 | S&F Stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staplescomplete all as secified and as directed |
| 23 | M&L for MS framed work such as grills,gratings, etc.. with ends of bars shouldered and/or riveted,or forged into spikes; framed guard bars; barred iron doors;ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed. |
| 24 | M&L for rolled sections as in main and cross beams, hip and jack rafters, purlins where connected to comman rafters and running rails fixed with angle cleats or other connecting plates conforming to Fe 410 W (Gde E-250) quality-A including welded to rafter,purlin complete all as specified and directed. |
| 25 | M&L for Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment etc conforming Fe-410W(GdeE-250) quality -B complete all as specified and directed. |
| 26 | M&L for Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 conforming to Fe 410 -W (Gde E- 250) quality A complete all as specified and directed. |
| 27 | S&F Steel ventilator with top hung shutter including hinges, steel peg stay, complete all as specified and directed. |
| 28 | M&L for 1.25mm thick pressed steel door frame of size 165mm x 60mm with one or more rebates including necessary , hinges, lock strike plate, fixing lugs etc complete as specified. |
| 29 | M&L for anodised aluminium snap grid (SIZE-605x605MM) frame work for false ceiling complete all as specified and directed. |
| 30 | S&F of Gl frame work of Size of grid 605 x 605mm for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre including provision of hangers (length of hangers as required at site ) made of 4 mm dia GI wire and other accessories including 10 mm thick PVC insulation panels with EPS stuck to 1 mm plain PVC sheet complete all as specified and directed. |
| 31 | S&F Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified and directed. |
| 32 | S&F Pre- painted coloured trapezoidal profiled Galvalume/ Zincalume sheet with min thickness 0.50mm TCT confirming to IS - 513(AZ-150 GSM, Al Zn allay metalic coating with 550 Mpa yield stress as per AS-1397) as in roof covering/cladding to wall, fixed with self tapping screws colour exterior coat of silicon modified polyster/BHP x RW paint system 20 micron top coat applied over 5 micron primer and 5 micron polyster back coat applied over 5 micron primer , all fixed with galvanized self drilling self tapping fastner (12-14 x 55 with EPDM seals) complete all as specified and directed. |
| 33 | S&F Pre- painted coloured plain sheet Galvalume/ Zincalume sheet with min thickness 0.50mm TCT confirming to IS - 513(AZ-150 GSM, Al Zn allay metalic coating with 550 Mpa yield stress as per AS-1397) as in roof covering/cladding to wall, fixed with self tapping screws colour exterior coat of silicon modified polyster/BHP/ XRW paint system 20 micron top coat applied over 5 micron primer and 5 micron polyster back coat applied over 5 micron primer , all fixed with galvanized self drilling self tapping fastner (12-14 x 55 with EPDM seals) complete all as specified and directed. |
| 34 | Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings,heads, shoes, bends, swan-necks,etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories) complete all as specified and directed. |
| 35 | Dismantling of floor, hearth or wall tiling / Paving Blocks including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises etc complete all as specified and directed. |
| 36 | Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc. complete all as specified and directed. |
| 37 | M&L for sheet glass, 4mm thick, ordinary quality and glazing with oil putty in squares n exc. 0.50 Sqm each pane complete all as specified and directed. |
| 38 | S&F 4.0mm thick Figured glass, pin head type and glazing with oil putty in squares n exc 0.5 sqm in each pane complete all as specified and directed. |
| 39 | M&L for preparation of untreated new wood/wooden surface of any description over 10cm width or girth and applying two coats of synthetic enamel paint (1st grade quality) over a coat of pink primer complete all as specified and directed. |
| 40 | M&L for one coats of synthetic enamel paint on old treated steel surfaces of any description over 10cm in width or girth including preparation of surfaces complete all as specified and directed. |
| 41 | M&L for two coats of synthetic enamel paint over one coat of red oxide on new steel surfaces of any description over 10cm in width or girth including preparation of surfaces complete all as specified and directed. |
| 42 | S&F steel water tubes medium grade galvanised with all fittings laid in trenches bore of tube 25 mm complete all as specified and directed. |
| 43 | S&F medium grade galvanized steel tubing with all fittings & fixed complete to walls & ceiling or laid in floors 20 mm dia bore pipe (including in short length) complete all as specified and directed. |
| 44 | Taking up or down steel tubing and connections,including cleaning for refixing or removal to store bore of pipe 15 mm complete all as specified and as directed |
| 45 | Taking up or down steel tubing and connections,including cleaning for refixing or removal to store bore of pipe 20 mm complete all as specified and as directed |
| 46 | Taking up or down steel tubing and connections,including cleaning for refixing or removal to store bore of pipe 25 mm complete all as specified and as directed |
| 47 | S&F rotational moulded PVC water storage tank 1000 ltrs capacity conforming to IS-12701(1989) cylindrical vertical type double-layered with closed top (thereated) including inlet,outlet and wash out holes of approved make hoisted and fixed in position all as specified in SSR Part I etc completge all as specified and directed. |
| 48 | S&F in repair fancy type, chromium plated stop valve/ angle valve cast copper allow screw down high pressure with crutch or butterfly handle screwed both end form iron pipe or for union and fixed of size 15mm dia complete all as specified and directed. |
| 49 | S&F in repair fancy type with long shank and cup (concealed type) chromium plated stop valve cast copper allow screw down high pressure with crutch or butterfly handle screwed both end form iron pipe or for union and fixed of size 15mm dia complete all as specified and directed. |
| 50 | S&F ball valves for 20mm bor dia of pipe high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. (Minimum weight 15mm-142gms/ 2 0mm-210gms./25mm-455gms/ 40mm - 690 gms) complete all as specified and directed. |
| 51 | S&F grating doom 100mm dia of PTMT (minimum weightt 25 gm) for floor trap/nahani trap, complete all as specified and directed. |
| 52 | S&F in repair PVC connections pipe ,15mm dia size with PTMT nuts of length 450mm complete all as specified and directed. |
| 53 | S&F 75mm PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed. |
| 54 | S&F 110mm PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed. |
| 55 | S&F 75mm bore PVC (SWR) bends with rubber ring joints any radius complete all as specified and directed. |
| 56 | S&F 110mm bore PVC (SWR) bends with rubber ring joints any radius complete all as specified and directed. |
| 57 | S&F 110mm bore PVC (SWR), junction single, (Single T) equal or unequal complete all as specified and directed. |
| 58 | S&F 110mm bore PVC (SWR) vent cowl complete all as specified and directed |
| 59 | S&F 110mm bore PVC (SWR) `P' or 'S' trape complete all as specified and directed. |
| 60 | S&F in repair 600mmx450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed. |
| 61 | Demolition of Brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings,dressed stonework and precast concrete articles complete all as specified and directed. |
| 62 | Dismantling of stone slabs and tiles of any description or thickness in floors, approachs, dado/Partitions laid bedded and pointed in any mortar etc complete all as specified and directed |
| 63 | Demolition of Concrete un- reinforced of any description and in any position not otherwise specifically provided for complete all as specified and directed. |
| 64 | Dismantling timber scantlings 40 sqcm and over in section, in framed section any position like trusses, rafters, purlins etc. complete all as specified and directed. |
| 65 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed. |
| 66 | Dimantling of Asbestos cement (corrugated,semi corrugated, etc.) sheets in roof coverings including ridges etc complete all as specified anddirected |
| 67 | Dismantling wall and ceiling board( fiber, pulp, insulation, etc.) or insulation board/slab/ blankets, any thickness, including cover fillets complete all as specified and directed. |
| 68 | M&L for Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors,windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS:733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary fittings and filling up the gaps at junctions, i.e. at top,bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle,Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, complete all as specified and directed. Please Enable Macros to View BoQ information |
| 69 | M&L for Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors,windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS:733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary fittings and filling up the gaps at junctions, i.e. at top,bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle,Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, complete all as specified and directed. Please Enable Macros to View BoQ information |