| 1 | (SECOND FLOOR) |
| 2 | Brick work withFly ash bricks 25 cm x 12 cmx8cm size having crushing strength not less than 75 Kg/cm2 with dimensional tolerance +8 percent in cement mortar (1:6) in Superstructure including cost, conveyance, royality etc complete as direction by EIC. |
| 3 | R.C.C. work M-20 grade with 20mm and down grade black hard granite crusher broken stone chips including hoisting and laying with Centering & shuttering as direction of EIC. |
| 4 | Column (M20) |
| 5 | Lintel (M20) |
| 6 | Staircase (M20) |
| 7 | Roof Beam (M20) |
| 8 | Chhaja (M20) |
| 9 | Roof Slab (M20) |
| 10 | Providing M.S. reinforcement for R.C.C. work including cutting, bending, binding and tying the grills and placing in position including cost of binding wire 18 to 20 gauge etc complete as direction by EIC. |
| 11 | 16 mm thick cement plaster over fly ash Brick Masonery with C.M ( 1:6) over work including cost, conveyance, royality of all materials etc complete as direction by EIC. |
| 12 | 16 mm thick cement plaster over fly ash Brick Masonery with C.M ( 1:6) over work including cost, conveyance, royality of all materials etc complete as direction by EIC. |
| 13 | Supplying, fitting and fixing of M.S. grill in windows including screws as may be required etc with cost, conveyance, taxes of all materials, labour, T&P etc. required for the complete in all respect as direction by EIC. |
| 14 | Fixing Vitrified tiles in floors on 25mm thick bed of cement mortar 1:1 (1 cement : 1 sand) jointed with neat cement slury mixed with pigment to match the shades of the tiles including rubbing and polishing complete including cost of precast tiles etc complete as per specification and direction of engineer in charge. |
| 15 | Fixing Ceramic tiles in floors & wall on 25mm thick bed of cement mortar 1:1 (1 cement : 1 sand) jointed with neat cement slury mixed with pigment to match the shades of the tiles including rubbing and polishing complete including cost of precast tiles etc complete as per specification and direction of engineer in charge. |
| 16 | Fixing granite slab in floors on 25mm thick bed of cement mortar 1:1 (1 cement : 1 sand) jointed with neat cement slury mixed with pigment to match the shades of the tiles including rubbing and polishing complete including cost of precast tiles etc complete as per specification and direction of engineer in charge. |
| 17 | Providing and fixing of FRP door with required fitting fixture etc complete in all respect as direction by EIC |
| 18 | Supplying, fitting & fixing of two track UPVC sliding window of approved make with 6mm thick glass of approved quality complete with frame, shutters and all fitting and fixtures etc complete in all respect as direction by EIC. |
| 19 | Supplying, fiting and fixing of 32mm thick flush door shutter with frame choukatha with approved quality of 30mm thick BWR block board pasted with 1mm thick sunmica on both side and outer choukatha portion 1'0\\" wife panelling of approved design and quality including cost of all door fitting and fixture etc. complete |
| 20 | Painting two coats to the wall surface by using 100% premium Acrylic emulsion paint to interior wall (distmper)surface over a coat of primer with water bond cement primer after preparing the surface smooth by applying putty punning with Synthetic Acrylic wall putty including finishing the surface smooth by sand papering in all heights etc. complete in all respect.any approved shade including cost conveyance royality etc complete as per direction of EIC |
| 21 | Wall painting two coats with 100% Acrylic emulsion paint (1st quality) exterior grade(weather coat) over a coat of primer with water bond cement primer applying putty punning with Synthetic Acrylic wall putty in all heights with all scaffolding and staging charges including cost, conveyance, taxes of all materials, cost of all labours, T & P, sundries etc. as required for the work complete. |
| 22 | Painting 2 coats with any enamel paint on new work over primer including cost of paint & primer , labour. over a coat of priming including all costs of labour ,Paint, primer, brushes and putty required for the work etc complete and as per direction of Engineer-in-charge. |
| 23 | Supplying ,fitting and fixing of stainless steel of 304 grade in hand railing using 50mm dia of 2mm thick circular pipe with balustrade of size 32mmx32mmx32mm in three rows in staircase as per approved design and specification,buffing,polishing etc.with cost conveyance,of all materials,labour,T&P etc required for the complete in all respects. |
| 24 | Provision for internal eletrification work complete in all respect as direction by Enginner-in-charge. |
| 25 | Provision for internal PH & Sanitary work complete in all respect as direction by Enginner-in-charge. |
| 26 | INTERIOR WORKS (SECOND FLOOR) |
| 27 | Providing and fixing cupboard racks of various sizes in proper position of shelves as per approved design with lower drawer system made up of fire retardant wpc board and block board of approved make, exposed member as per drawing to be finished with 1mm thick laminate of approved make and shade and design. The inner unexposed will be finished with 0.8 mm thick laminate and mirrior fixing on front door portion of approved make including all fittings & fixtures complete as direction of Engineer in-charge. |
| 28 | Providing & fixing of suspended ceiling system with primafine fissured microlook tiles(Armstrong) of size 600X600 mm with humidity nesistance of 99% silfutte reavel profile grid system with 3mm or 6mm centre recess,Main runner should be placed at 1200 mm securely fixed to structural to fited by approved hanger forming a grid of 600mmX600mm with all hardwares & labour charges complete as per the direction of the Engineer in-charge. |
| 29 | Provision,Supply & fitting and fixing of dining table (SS) including all required fitting & fixture incluiding cost & convenance as directed by the EIC |
| 30 | Provision,Supply & fitting and fixing of dining chair (SS) including all required fitting & fixture incluiding cost & convenance as directed by the EIC |
| 31 | Provision,Supply & fitting and fixing of Single bed with matteres,pillow etc including all required fitting & fixture incluiding cost & convenance as directed by the EIC |
| 32 | Provision,Supply & fitting and fixing of single chair including all required fitting & fixture incluiding cost & convenance as directed by the EIC |
| 33 | Provision,Supply & fitting and fixing of single Table including all required fitting & fixture incluiding cost & convenance as directed by the EIC |
| 34 | Provision,Supply & fitting and fixing of Sofa set with center table including all required fitting & fixture incluiding cost & convenance as directed by the EIC |
| 35 | Wiring for Circuits and Submain with following number & sizes of PVC insulated 1100 Volt Grade Multistranded Copper Conductor FRLS Wire run inside 2 mm thick PVC Conduit Pipe Recessed in Ceiling / Column / Walls of Building including supply of all materials such as wires, PVC Conduit, Junction Box & Pull Box etc. complete with making good the damages caused as required and as per Direction of Engineer-In-Charge. |
| 36 | 2 Nos. Single Core 2.5 mm2 Copper Wire for Phase and Neutral and 1 No. Single Core 1.5 mm2 Copper Wire for Earth Continuity Conductor as per SLD (from LDB to Room & Power Point and Common Light Point looped). |
| 37 | 2 Nos. Single Core 4.0 mm2 Copper Wire for Phase and Neutral and 1 No. Single Core 2.5 mm2 Copper Wire for Earth Continuity Conductor as per SLD. |
| 38 | 4 Nos. Single Core 6.0 mm2 Copper Wire for Phase and Neutral and 2 Nos. Single Core 4 mm2 Copper Wire for Earth Continuity Conductor as per SLD. |
| 39 | Supply, of 18 watt decorative lights of approved make with all required fittings complete |
| 40 | Supply,Installation,Testing , Commissioning of 2 ton Capacity Cassate AC of approved make with all required fittings complete |
| 41 | Supply,Installation,Testing , Commissioning of 100 ltr refrigerator of approved make with all required fittings complete |
| 42 | Supply fitting and fixing in 100 ltr water purify (cold & normal)including etc complete as specified and directed Engineer-in-Charge. |
| 43 | Provision for fire extinguishers ABC of approved make to be placed in required position as directed by Fire Authority / Engineer in-charge. |
| 44 | Provision for 6kg CO2 fire extinguishers for electrical equipmrnt of approved make to be placed in required position as directed by Fire Authority / Engineer in-charge. |
| 45 | Provision for Handloom/Handicrafts photo frame Engineer in-charge. |
| 46 | Provision for Handloom/Handicrafts window blinds Engineer in-charge. |
| 47 | Supply, installation, testing and commissioning of OTIS / KONE/ THYSSENKRUPP / MITSUBISHI make electric traction lift as per necessary approved specifications. The lift should comply with ISI specifications with latest technology equipped with one year AMC completed as directed by Engineer in-charge. Please Enable Macros to View BoQ information |