| 1 | Taking down chowkats or frame with shutter (without taking out shutter from the frame) not exceeding 1.50 sqm each as doors, windows & ventilators etc. and removal from site complete all as specified and directed. |
| 2 | Taking down chowkhats or frame exc 1.5 Sqm but n.exc 4 Sqm each with shutters (W/out taking off shutters from the frames).and removal from site all as specified and directed. |
| 3 | Providing and fixing factory made uPVG white colour Sliding window Three track made of extruded profiles with wall thickness of 2.3mm (+ -0.2mm). Window profile with hollow section with multi chamber. Frame (88mm x 52mm), sliding sash (42mm x 67mm). Sliding mesh Sash (42mm x 57mm) Sliding interlock (One vertical length in each shutters) (45.5mm x 28mm), Glazing bead (24.5mm x 16mm) will be miterd cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware. EPDM gasket, 1.2+ -0.2mm thick galvanised steel Frame (30mm x 18mm) 2 nos, sliding sash (30mm x 18mm), sliding mesh sash (26mm x 10mm) profile to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners, Hardware [Touch Lock of zinc alloyed (white powder coated), steel roller system. Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and required accessories.Note:- The unit rate quoted by contractor excludes cost of glass & wire mesh and includes all other connected accessories. Net Opening will be measured for payment purpose. Wire mesh and Glass Shall be measured and paid Seperatly .Provision of all other items as shown on DWgs & Cutting holes of suitable depth in wall for inserting lugs etc including making good dismentalled portion with PCC (1:2:4) type B-0 using 12.5mm graded crushed stone aggreegate and cement mortar (1:3) shall be deemed to be includedNote :- Description of items amend accordingly as per manufacturer instructions, Note : 1: Test certificate of manufacturer to be provided by contractor . 2. Embossing with barcode of manufacturer engraved over each door frame and shutter is manadatory. |
| 4 | S & F factory made uPVC window or ventilator side hung/top hung (glazed and gauge both) white colour casement (Openable) window made of extruded profiles with wall thickness of 2.3mm ( + – 0.2mm). Window profile with hollow section with multi chamber, frame (60mm x 58mm), sash (60mm x 73mm), T profile (One vertical length in between two shutters) (60mm x 74mm), Glazing bead (35mm x 20mm) will be mitered cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware. EPDM gasket 1.2 +– 0.2mm thick, galvanized steel Frame (28mm x 21.5mm), sash (31mm x 27.5mm). T profile (27mm x 17mm) to be inserted in required profile, frame will be fixed to the wall with 8 mm x 100mm long fasteners. Hardware: [casement handle made of zinc alloyed (white powder coated), But Hinges of' zinc alloyed (white powder coated), transmission gear made of mild steel with multi point locking system] and 5mm thick glazing with selected quality glass.Note: The unit rate quoted by contractor excludes cost of glass & wire mesh and includes all other connected accessories. Net Opening will be measured for payment purpose. Wire mesh and Glass Shall be measured and paid Seperatly. Provision of all other items & Cutting holes of suitable depth in wall for inserting lugs etc including making good dismentalled portion with PCC (1:2:4) type B-0 using 12.5mm graded crushed stone aggreegate and cement mortar (1:3) shall be deemed to be include.Note :- Description of items amend accordingly as per manufacturer instructions, Note : 1: Test certificate of manufacturer to be provided by contractor . 2. Embossing with barcode of manufacturer engraved over each door frame and shutter is manadatory. |
| 5 | Supply and fixing Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/Ceosetory windows & other Frames/Chowkhat of size 45 x 70 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. Note: (i) For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made(ii) Cost for M.S. hold fast/ lugs or SS dash fasteners shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account. |
| 6 | Supply and Fixing Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 65 x 100 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge.Note: (i) WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made.(ii) Cost for M.S. hold fast/ lugs or SS dash fasteners shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account. |
| 7 | Supply and fixing Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/Ceosetory windows & other Frames/Chowkhat of size 65 x 125 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum comp ressive strength of 58 N/mm2 , modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. Note: (i) WPC solid door/window frames,minus 5mm tolerance in dimension i.e.depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made (ii) Cost of MS hold fast/lugs or SS dash fasteners shall be deemed to be included in the quoted unit rate nothing extra shall be paid on this account. |
| 8 | Supply and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of size 30mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non-toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-in-Charge including supply and fixing following items :(a) Stainless Steel (304 Grade) Finished Butt Hinges 100mm - 4 nos. per leaf(b) Stainless Steel (304 Grade) Finished Square Tower Bolt 150 mm long - 2 nos per leaf (c) Stainless Steel (304 Grade) Finished Handles 150 mm - 2 nos. per leaf |
| 9 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of size 35 mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/ rice husk/ wheat husk) and non-toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, complete all as per direction of Engineer- in-Charge including supply and fixing following items :(a) Stainless Steel (304 Grade) Finished Butt Hinges 100mm - 4 nos. per leaf(b) Stainless Steel (304 Grade) Finished Square Tower Bolt 200mm long - 2 nos per leaf(c) Stainless Steel (304 Grade) Finished Handles 200 mm - 2 nos. per leaf(d) Stainless Steel (304 Grade) Finished Sliding Bolt 300 mm - 1 no. per leaf(e) Stainless Steel (304 Grade) Finished Floor Door Stopper - 1 nos. per leaf |
| 10 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type Skelton door shutter of size 35 mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/ rice husk/ wheat husk) and non-toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, including S&F of stainless steel 304 Grade (natural finish) wire cloth complete all as per direction of Engineer- in-Charge including supply and fixing following items :(a) Stainless Steel (304 Grade) Finished Butt Hinges 100mm - 4 nos. per leaf(b) Stainless Steel (304 Grade) Finished Square Tower Bolt 200mm long - 2 nos per leaf(c) Stainless Steel (304 Grade) Finished Handles 200 mm - 2 nos. per leaf(d) Stainless Steel (304 Grade) Finished Sliding Bolt 300 mm - 1 no. per leaf(e) Stainless Steel (304 Grade) Finished Floor Door Stooper - 1 nos. per leaf(f) Stainless Steel (304 Grade) wire cloth fixing as per manufacture |
| 11 | Supply & fixing aluminium (extruded section body) Door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed (IS Marked) complete all as per direction of Engineer- in-Charge |
| 12 | S& F Stainless steel wire cloth 0.36 mm nominal dia of wire and avarage width of aparture 1.40mm and fixed including necessary beading etc. complete all as specified and directed. |
| 13 | M & L Toughned glass ordinary quality 5 mm thick fixed to steel, metal, UPVc or wooden window frames complete all as specified and directed. |
| 14 | All as per item here in above but 5 mm thick pin head type figured glass complete all as specified and directed. |
| 15 | Dismantling boarding any description fixed in any position with nails complete all as specified and directed. |
| 16 | Supply & fixing HDHMR Board , 18/19mm thick, density over 850kg/cum, having a class A fire rating, grade 2 quality, commercial type, fixed with screws to timber frame work as in Kitchen cup board Shutter / shelves / cabinet etc complete all as per direction of Engineer- in-Charge |
| 17 | M&L for 0.90mm thick decorative laminates 'Mica type 1 of surface finished,colour and pattern as approved, fixed with adhesive also on edges of cupboard shutter as per makers instructions |
| 18 | M &L for providing Modular Kitchen Cabinet/cup board with shutters in required sizes & shape at site made out of HDHMR Board , 18/19mm thick, density over 850kg/cum, having a class A fire rating, grade 2 quality, commercial type, fixed with screws to timber frame work as in Kitchen cup board Shutter / shelves / cabinet etc consisting of both side 0.90 mm laminate one side decorative & other side Plain(white).The panels shall be fabricated using adhesive and screws where ever required .All the edges shall be covered with 2 mm thick edge bonding tape or 90 degree edge bent finish as per manufacturer instructions and as directed by Engineer-in-Charge |
| 19 | S&F Cup Saucers fabricated with stainless steel section (SS-304), best quality of size 420 mm x 500 mm x 100mm for different use such as placing plain plate /cutlery etc fixed in position complete all as specified and directed by Engr In charge |
| 20 | S&F Cutlery set & Dustbin fabricated with stainless steel section (SS-304), best quality of size 420 mm x 500 mm x 150 mm for different use such as placing cup & saucer etc fixed in position complete all as specified and directed by Engr In charge |
| 21 | S & F Stainless steel fancy type 200 mm handle complete all as specified and directed by Engr In charge |
| 22 | S & F Telescopic Ball bearing Channel chromium plated of size 500 mm (when closed) fix to kitchen basket complete all as specified and directed by Engr In charge Make :- godrej, Link,Hettich |
| 23 | S& F Auto Closing Concealed Hinges for Half Overlay Doors with 95 Degree Opening Angle complete all as specified and directed by Engr in charge |
| 24 | S&F 25 mm size magnetic catches with Plastic body and striking plate including letting in and fixed complete |
| 25 | S&F continuous (piano) hinges 30MM width of flap, mild steel bright finish or electrogalvanised of complete all as specified fixed with CP steel screws. |
| 26 | Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar work con- forming to Fe.290.Gde-E-165 complete all as specified and directed. |
| 27 | Demolition of Cement concrete (unreinforced) of any description and in any position not otherwise specifically provided and removing rubbish from the site as directed complete all as directed. |
| 28 | Material and labour for water proofing treatment to RCC sunken slab and adjoining vertical slab as described following any one method complete as per directions of GE. 1. Method 1 (A) Supplying and applying two component elastomeric acrylic polymer modified cementitious waterproofing coating, Smart Care Damp proof 2K, having 100% elongation as per ASTM D412, resisting 5 bars hydrostatic pressure as per DIN 1048, reduction to rapid chloride shall be 70 as per DIN 1048, crack bridging upto 1.2mm as per ASTM 4548.5 Clean all working surface & made free from dirt, grease laitance etc. After inspection for all working area rough surface, cracks & construction joint are treated by polymer modified mortar of 1:1:4 (1 Cement : 1Polymer : 4 Sand). Making Gola of size 75x75mm at junction of vertical & horizontal with the polymer modified mortar of 1:1:4 (1 Cement : 1 Polymer : 4 Sand). The coating shall be terminated at 1600mm in toilet/2100mm in bathroom on vertical walls. The mixing ratio of the coating shall be 2 parts of powder & 1 part of liquid without any water addition in the mixing and shall have consumption of 1.5kg/sqm per coats, etc, complete as per manufactures specifications.(B) Bore Packing: All the borehole gaps between concrete surface and PVC pipe of various dia upto the neck level shall be filled with non-shrink free flow grout – Smart Care GP Grout having dual shrinkage compensation property. Before the bore packing, surface of the PVC pie and concrete surface will be made rough and sand will be sprinkled with polymer bonding agent.(C) Apply12-15mm plaster on slab and vertical surface admixed with Smart Care Vitalia Neo @200ml per bag of cement before treatment.2. Method 2 (A) Supplying and applying two component cementitious & acrylic flexible water proofing & protective coating, two coats with 1mm DFT, having Hydrostatic (positive) water pressure resistance (DIN 1048) is 7. Abrasion resistance, cm/km is 0.09 of Dr Fixit Pidifin 2k @ 1.5kg/sqm with a paint brush over existing slab surface and adjoining vertical surface. The Polyester reinforced coated net 3. of 45g/sqm, 2.5mmx2.5mm is laying on the surface immediately on the first coat of two component modified polymer Dr Fixit pidifin 2k. After removal of all lose materials like dust etc. with wire brush coir brushes from surface to get absolutely cleaned surface free of foreign contaminant filling of crack and patches with polymer based mortar/micro concrete, after that making the gola on surrounding wall’s junction and seal the vertical walls. In case of core cutting on the surface, the joint is seal with non-shrink grout.(B) The coating shall be terminated at 1600mm in toilet/2100mm in bathroom on vertical walls.(C) Apply12-15mm water proof plaster on slab and vertical surface admixed with Dr Fixit pidiproof LW+ @200ml per bag of cement before treatment.3..Make : Method 1 (Asian paint)/ Method 2 (Dr fixit) or Techno commercial equivalent in make mentioned in Appx 'B' approved by CWE Note :- (i) The treatment shall be carried out by authorised applicator (through specialized agency ) approved by CWE as per the manufacturer.(ii) PCC filling under sunken area will be measured & paid separately (iii) Treatment should be conitue upto 450mm height on vertical wall of sunken but only plan area of sunken will be measured for payment. |
| 29 | PCC 1:5:10, type E-2 as in filling of sunken floors etc. complete all as specified and directed. |
| 30 | PCC (1:3:6) type C-2 using 40mm graded aggregare 75mm thick as in plinth protection complete all as specified and directed. |
| 31 | Roughning of surfaces of old concrete floor by picking,sweeping clean and washing down with water to remove dust etc. complete all as specified and directed. |
| 32 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), terrazo dado/wall tiling and skirting. etc on brick or stone walls etc including racking out joints hacking for key and scrubbing and removing rubbish off the premises complete all as specified and directed. |
| 33 | Dismantling stone slabs of any description or thickness in floors, apron etc laid bedded and pointed in any mortar complete all as specified and directed. |
| 34 | Material and labour for 7 to 8 mm thick non-skid ceramic colour (light shade) joint free tiles with matt finish premium quality having water absorption should be between 3% to 6%, square/ rectangular, area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm as in floor, set and jointed using type-I adhesive (thick bed fixing) confirming to IS-15477:2004 including necessary cutting as per site requirement, complete all as specified and directed by Engineer-in-Charge. |
| 35 | Material and labour for Double charge vitrified coloured tiles (approved shade) of size 600mm x 600mm having thickness 8 to 9 mm premium quality having water absorption less than 0.08%, straight edge, stain free, glossy finish, square marbonite, laid as in floor, set and jointed using type-I adhesive (thick bed fixing) confirming to IS-15477:2004 and pointed in white or coloured cement to match the shade of tile including necessary cutting as per site requirement, complete all as specified and directed by Engineer-in-Charge. Make : Johnson (Snow Flair/Albano White Plus/Albano Lemon Plus) or Techno commercial equivalent in make mentioned in Appendix 'B' |
| 36 | Ditto all as above item but as in skirting, but tiles laid over and including 10 mm thick bedding layer in cement mortar (1:3) complete all as specified and as directed by Engineer-in-Charge. |
| 37 | Material and labour for Providing and Laying Premium (1st) quality having water absorption should be between 10% to 20%, digitally printed straight edge, punched, glazed ceramic rectangle tile in approved shade and finish with flexural strength greater than 16 N/mm2, scratch hardness on Moh’s Scale minimum 3 and crazing resistance of 2 cycles in coloured tiles 600 X 300 mm and 7 mm thick, in any pattern of light & dark/highlighters tiles etc as approved, on vertical surfaces such as in skirting/dado etc, set and jointed in cement slurry over & including 10 mm thick rendering in cement mortar (1:4) and pointed in white cement with pigment to match the colour of tiles complete all as specified.Note : Dado should be flushed with the wall plastering.Make : Johnson (Digital HD Tiles) (Barstow DK/LT/HL for Toilets & Verona LT/HL for Kitchens) or Techno commercial equivalent in make mentioned in Appendix 'B' |
| 38 | Material and labour for Rajasthan black granite (Telephonic Z-black) , machine cut as in shelves/steps/cills/jambs/skirting/border only in tile flooring and the like works and flooring etc, 20 mm thick including bull-nose the front length, set and jointed in cement slurry over & including screed of 15 mm thick rendering in cement mortar (1:4) and pointed in cement mixed with pigment to match the shade of slab including rubbing, cutting and mirror type granite polishing complete all as specified and as directed by Engineer-in-Charge.Note : Single piece should be used in steps/cills/jambs/shelves. |
| 39 | Material and labour for anti skid full body vitrified step tiles 10mm thick bull noses and self embossed or grooved as in treads & landing (single piece length wise upto 1200mm) laid over and including screed bed 15mm thick in CM 1:4 complete all as specified as directed. |
| 40 | Material and labour for anti skid full body vitrified step tiles 10mm thick as in riser, skirting (single piece length wise upto 1200mm) laid over and including screed bed 10mm thick in CM 1:3 complete all as specified as directed. |
| 41 | Supply and fixing stainless steel pipe 25mm bore (as a curtain rod), wall thickness of pipe not less than 1mm and grade SS 202, fixed in position with fixing accessories like Brackets, finial and side holder of same manufacturer complete all as specified and as directed by Engineer-in-Charge.Note : (i) Brackets, finial and side holder shall be measured and paid separately for supply only but the cost for fixing the same shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account.(ii) Cost for screws, rawl plugs as required for fixing shall also shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account. |
| 42 | Supply and fixing single lever High concealed diverter flow consisting of exposed part kit with operating lever, wall flange & button and concealed body, cartdge sleeve and also including bath spout with flange chromium plated ,screwed down, high pressure complete all as specified and as directed by Engineer-in-charge.Make Cera:(exposed part F1018721, concealed part F4030101, bath Spout F1020661) or Techno commercial equivalent in make mentioned in Appendix 'B' |
| 43 | Supply and fixing in repair vitreous china premium/1st quality wash basin (under counter), white/ivory/off white, size 580x430 mm including S&F all accessories as recommended by manufacturer and incl. brass CP bottle trap 32 mm with inlet and outlet screwed for pipe or connections incl all necessary accessories for fixing, packing, union and incl 32mm brass CP waste coupling and complete fixed in position in all respect as per manufacturer's instructions and taking down existing of any description/size complete all as directed by Engineer-in-charge.Make : Hindware (WHB-Garnet (Cat No.- 10080), Waste Coupling-Cat No.- F850023 (Economy Model), Bottle Trap-Cat No.- F850072 (Economy Model) or Techno commercial equivalent in make mentioned in Appendix 'B' |
| 44 | Supply and fixing vitreous china premium/1st quality wall hung water closet with P trap white/ivory/off white including connection to drain (or out going pipe) and to flushing pipe, antisyphonagee pipe,etc., and incl. plastic soft close seat cover as recommended by manufacturer for particular model closed pattern with flat bottom etc; and incl S&F of all necessary accessories set like rag bolts/gel gasket/hinges etc as recommended by manufacturer for fixing, packing and taking down existing of any description/size complete in all respect all as specified.Make : Jaquar (Continental Series-CNS-WHT-963N or Techno commercial equivalent in make mentioned in Appendix 'B' |
| 45 | Supply and fixing health faucet (Hand Shower) fancy type, CP including 1.2 meter long 8mm dia wasy flex tube in chrome finish and including wall hook and fixing material, making connections and fixed in position complete all as specified and as directed by Engineer-in-charge. Make: Jaquar(continental series) ALD-573 / Hindware (contessa plus series)/ Cera (Ocean series) or Techno commercial equivalent in make mentioned in Appendix 'B' |
| 46 | Supply and fixing concealed flushing cistern of PVC 8 ltr. cap with dual flushing system, valveless syphonic action type, with inlet/outlet, ball valve, float and including brackets and connection to pipe etc. and incl S&F of all necessary accessories/installation kit and 'S' type drain pipe connetion set for wall hung WC etc as recommended by manufacturer for fixing, packing and including S&F of actuator knob/flush plates and and taking down existing of any description/size complete in all respect all as specified.Make : Jaquar (Concealed Cistern-JCS-WHT-2400S, Flush Plate-JCP-CHR-812415) or Techno commercial equivalent in make mentioned in Appendix 'B' |
| 47 | Supply and fixing Chromium plated overhead shower 100mm dia with shower arm of 300mm long 20mm dia round shape with 90º bend for wall mounted shower with flange of same make and incl all necessary accessories as recommended by manufacturer for fixing and taking down existing of any description/size complete in all respect all as specified.Make : Jaquar (Shower-OHS-1989, Shower Arm-SHA-479L450) or Techno commercial equivalent in make mentioned in Appendix 'B' |
| 48 | Supply and fixing towel rail CP 60 cm long between flanges and including all accessories like brackets/screws etc as recommended by manufacturer and complete fixed in position complete all as specified and as directed by Engineer-in-charge. Make : Jaquar/Cera/Hindware/Marc/Prima |
| 49 | S & F in repairs stainless steel Kitchen plate rack of overall minimum size 900mm x 750 mm x 250mm deep, with partitions for small/large plates etc made out of stainless steel 0.80 mm thick sheet fixed with rawl plug and CP steel screws complete, all as directed. |
| 50 | S&F double bowl stainless steel sink made of 1mm thick sheet for kitchen with plugs, washers and wastes, including fixing with cast iron cantilever brackets, bedding in cement mortar on to dwarf wall, connecting union to pipe, overall minimum size 915mm x 460 mm and bowl size 410 mm x 330 mmx 160mm with including 32mm dia waste pipe of polythelene of low or high density, 32mm bore chromium plated brass waste fitting with long screwed shanks and fly nuts, flange end bedded in red lead cement & other end fixed, making holes in walls for brackets and fixed in CM 1:3 or PCC 1:2:4 type B0, complete, including taking down old unserviceable sink. |
| 51 | Supply & fixing of 16mm outer dia CPVC pipes SDR 11 including all fittings Plain/brass threaded CPVC SDR 11 fittings (like Elbow, Tee, Socket, Reducer, Union, Bushing, Step over bends, End cap, End Plugs, one side brass/two side brass etc) fixed along walls, ceiling or laying under floors etc and including CPVC solvent cement for jointing complete all as specified and as directed. |
| 52 | Supply & fixing GI tubing 20 mm bore medium grade galvanised with all fitting and fixed to walls & ceilings or laid in floors, bore of pipe 20 mm complete all as specified and directed Note: (i) Pipes inside the buildings shall be fixed concealed and outside the buildings shall be fixed on the surface along wall with and including suitable size clamps/brackets (interval of 2m and pipe keeping 100mm away from wall ) of suitable size fixed with fasteners/nut bolts, as directed by Engineer-in-Charge. (ii) Bracket, clamp, nut bolt, fastner, slotted channel etc shall be made of deep drawn low carbon steel material with hot dip zinc aluminium flake coated and fixed all as shown on BTD drawing cost for same shall deemed to be included in the quoted unit rate and nothing extra shall be admissible on this account. (iii) Cost for cutting chases in wall and making good disturbed surfaces as required shall deemed to be included in the quoted unit rate. |
| 53 | S & F Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed for 20mm dia bore pipe |
| 54 | Supply & fixing 110mm bore PVC SWR pipes single socketed in any length with rubber ring joints, fixed along walls with and including suitable size clamps/brackets (interval of 1m and pipe keeping 100mm away from wall ) of suitable size fixed with fasteners/nut bolts, joints fixed with pipe joint lubricant complete all as specified and as directed by Engineer-in- charge.Note:- Bracket, clamp, nut bolt, fastner, slotted channel etc shall be made of deep drawn low carbon steel material with hot dip zinc aluminium flake coated and fixed all as shown on BTD drawing cost for same shall deemed to be included in the quoted unit rate and nothing extra shall be admissible on this account. |
| 55 | Supply & fixing 75mm bore PVC SWR pipes single socketed in any length with rubber ring joints, fixed along walls with and including suitable size clamps/brackets (interval of 1m and pipe keeping 100mm away from wall ) fixed with fasteners/nut bolts, joints fixed with pipe joint lubricant complete all as specified and as directed by Engineer-in- charge.Note:- Bracket, clamp, nut bolt, fastner, slotted channel etc shall be made of deep drawn low carbon steel material with hot dip zinc aluminium flake coated and fixed all as shown on BTD drawing cost for same shall deemed to be included in the quoted unit rate and nothing extra shall be admissible on this account. |
| 56 | Supply & fixing 110mm bore PVC SWR pipes single socketed in any length with rubber ring joints, laid in trenches, joints fixed with pipe joint lubricant complete all as specified and as directed by Engineer-in- charge. |
| 57 | Supply & fixing 75mm bore PVC SWR pipes single socketed in any length with rubber ring joints, laid in trenches, joints fixed with pipe joint lubricant complete all as specified and as directed by Engineer-in- charge. |
| 58 | Supply & fixing uPVC bends (any radius) grade 'B' suitable for 110mm bore pipe complete all as specified and as directed by Engineer-in- charge. |
| 59 | Supply & fixing uPVC bends (any radius) grade 'B' suitable for 75mm bore pipe complete all as specified and as directed by Engineer-in- charge. |
| 60 | Supply & fixing uPVC junction (double T/socket) grade 'B' equal or unequal suitable for 110mm bore pipe complete all as specified and as directed by Engineer-in- charge. |
| 61 | Supply & fixing uPVC junction (double T/socket) grade 'B' equal or unequal suitable for 75mm bore pipe complete all as specified and as directed by Engineer-in- charge. |
| 62 | Supply & fixing PVC 110 mm bore (SWR) 'P’ trap complete all as specified and as directed by Engineer-in- charge. |
| 63 | Supply & fixing PVC (SWR) gully trap 125 X 125 mm, setting and jointing with solvent cement complete all as specified and as directed by Engineer-in- charge. |
| 64 | M&L PVC (SWR) 75 mm vent cowl complete all as specified and directed by Engineer-in-Charge. |
| 65 | M&L PVC (SWR) 110 mm vent cowl complete all as specified and directed by Engineer-in-Charge. |
| 66 | Dismantling of brick tiles or terracing tiles single layer on roof & disposal of retrieved material upto a distance n.exc 100m where directed, all as specified and directed. |
| 67 | Demolition of mud in roof, any thickness including plastering and leaping (where full thickness removed or only a part there of disposal off rubbish upto a distance n.exc 100m, where directed. |
| 68 | M&L for levelling course for roof slab, PCC type B0, 1:2:4 (12.5 mm graded aggrigate) for maintaning proper roof slope and finishing surface even and smooth etc complete all as specified and dirceted by Engineer-In-Charge. |
| 69 | Supply of SBR waterproofing compound @ 2% of per kg cement used complete all as specified . Make Fosroc/Sika/Choksey/Chemsol/Bostik/STP. |
| 70 | OVERLAY- PU BASED ELASTOMERIC LIQUID MEMBRANE SYSTEM FOR EXPOSED ROOF :- Providing and applying polyurethane liquid roof waterproofing with improved water ponding capability, thermal insulating elastomeric high build liquid membrane for concrete roofs for exterior wall and exposed surface with solid content not less than 80% and solar reflective index 109 as per (ASTM E-1980-19)/tear strength-20 N/mm (Free film, 14 days + 30 degree C) (ASTM D624) and tensile strength>- 2 N/mm2 (ASTM D4541). (a) After proper surface preparation, apply one coat of primer for PU coating as per manufacturers specificaiton. (b) Apply 1st coat of ShailUrethane(R)BTD (white) @ 650 gm/m2 (minimum) or equivalent by brush/roller white prime surface is tacky, spread waterproofing reinforced glass fiber mash of 45 GSM with overlaps of 50 mm in both directions when the surface is still tacky. Allow 1st coat to dry. (c) Apply 2nd & 3rd coat of ShailyUrethane(R)BTD (white) @ 650 gm/m2 (minimum) or equivalent by brus/roller. Make : Fosroc/sika/choksey/chemsol/Bostik/TP. Note (i) The mimium dry film thickness (DFT) of roof treatment shall be 1.5mm if any shortfall in thickness of above treatment the same shall be achieved by additional coat. (ii) The procurement of material and execution of material and execution of the work of water proofing treatment shall be carried out by authorised applicator approved by GE. (iii) The manufacturer/authorised applicator shall give a warranty for the performace & durability for 10 years. |
| 71 | M&L for Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, in soft/loose soil |
| 72 | M&L for PCC 1:3:6 type C-2 (using 40mm grade stone aggregate) as in foundation/ Post holes. |
| 73 | S & F Pre-painted galvatume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick any colour having tensile strength of 550 Mpa as in roof covering /cladding to wall fixed with self tapping screws complete all as per manufactures instructions with all fittings and accessories etc complete all as specified and directed. |
| 74 | Preparation of new steel surfaces of steel of any description , over 10 cm width or girth not otherwise described and apply two coats of synthetic enamelled paint over a coat of red primer complete all as specified. |
| 75 | M&L for MS Plates (plain or chequrred) channels,square cut or notched (ordinary and counter sunk) forming holes without any attachment with MS Gde Fe 410, E-250 quality A, complete all as specified and directed. |
| 76 | S&F tee,angles,channel or flat section including distances cleats for roof trusses (framed),trussed,purlinn,crane gantries,rails and fastening and heavy brackets framing etc conforming to Fe 410-W(Gde-E-250) complete all as specified and directed by Engr-in-charge. |
| 77 | Taking down Cement plaster including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed. |
| 78 | Rendering 15mm thick in cement mortar 1:6 on internal surfaces of brick work or concrete surfaces and finishing the surface even & smooth without using extra cement complete all as specified and as directed. |
| 79 | Rendering 15mm thick in cement mortar in 1:4 on external surfaces of concrete surfaces even and smooth without using extra cement & with using integral water proofing compound (as per manufacturer's instructions) complete all as specified and as directed. (Note: WPC shall be measured and paid for separately) |
| 80 | M&L for rendering 5 mm thick in cement mortar 1:3 on concrete surfaces in ceiling, finished even & smooth without using extra cement, complete, all as specified. |
| 81 | Dismantling of brick work of any type built in cement mortor in any condition etc complete all as specified and directed. |
| 82 | M&L brick work with sub class B bricks straight or curved on plan exceeding 6 mtr mean radius in cm 1:6 etc.complete all as specified and directed by Engineer - in - Charge. |
| 83 | M&L half brick work with sub class B bricks straight or curved on plan exceeding 6 mtr mean radius in cm 1:6 etc.complete all as specified and directed by Engineer - in - Charge. |
| 84 | Dismantling PVC water tank/RCC tank and removing for capacity exceedin 250 litres & not exceeding 500 litres etc., all as directed. |
| 85 | Dismantling PVC water tank/RCC tank of water tanks of capacity exc 500 Ltr & n.exc 1000 Ltr and removing from site all as specified. |
| 86 | S&F 1000 Litre capacity Rotational moulded polyethylene water storage tanks Triple layered White coloured (cylindrical, vertical with closed top) ISI marked, hoisted & fixed in position including 20 mm ball valve & making necessary arrangements for fixing inlet, outlet & over flow pipe & provision of wash out pipe etc. complete, all as specified and directed. Make: Sintex/Dhara/Rotex |
| 87 | S&F 500 Litre capacity Rotational moulded polyethylene water storage tanks Triple layered White coloured (cylindrical, vertical with closed top) ISI marked, hoisted & fixed in position including 20 mm ball valve & making necessary arrangements for fixing inlet, outlet & over flow pipe & provision of wash out pipe etc. complete, all as specified and directed. Make: Sintex/Dhara/Rotex |
| 88 | Demolition of RCC of any description such as Kitchen chimney, chajja, shelves, OHT Tanks. etc and in any position not other wise specially provided for complete all as specified and directed. (Note: Reinforcement cut as required to facilitate demolition) |
| 89 | Reinforced cement concrete type B1 1:2:4 (20 mm graged aggregate) as in Slab supported on walls, beams and column in floors, roofs, landings, balconies, deck slabs and in shelves and etc. and setting in mortar complete with joints to match complete all as specified and directed. |
| 90 | M & L RCC M25 (20mm graded stone aggregate) design mix as in chajja complete all as specified and directed by Engineer-in-charge. |
| 91 | TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips all as specified and directed. |
| 92 | TMT bars 8 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips all as specified and directed. |
| 93 | Use and waste of form work to rough finished surfaces of soffits of suspended slab such as roof slabs, floor slabs, landings and similar work not exceeding 200mm thick complete all as specified and directed. |
| 94 | Formwork to chajjas, troughs and similar items including edges for rough finished surface of concrete |
| 95 | M&L for welding in repairss Thickness of metal to be welded will be Exc 9 mm but not exc 20mm complete all as specified and directed by Engineer - in - Charge. |
| 96 | M&L for Obliterating old writing of any description, n exc 0.1 sq. m, with paint to match existing work etc complete all as specified and directed by Engineer - in - Charge. |
| 97 | M&L for Writing letters or figures with fluorecent paint ( Block. Roman, Italic or Indian) n exc. 30 cm high etc complete all as specified and directed by Engineer - in - Charge. |
| 98 | M&L for preparation of new steel surfaces of any description over 10cm width or girth and applying a coat of red oxide zinc chrome primer and two coats of synthetic enamel paint (for steel surfaces) including preparation of surface complete all as specified. |
| 99 | M&L for preparation of old painted surfaces including as knotting, stopping, Burning off or removing, scraping etc,and then applying two coat of synthetic enamel paint (ordinary tint) on steel surfaces over 10cm width or girth complete all as specified and directed by Engineer - in - Charge. |
| 100 | Stainless steel fancy type peg set of six and fixed in position with steel screws complete all as specified and directed. |
| 101 | Drilling Holes of 12mm dia up to 100 mm deep holes in structural members at the interval of 300 mm in staggered manner or along the crack line in Reinforced Concrete (RC) structural element including cleaning of the holes by air blower and inserting 12mm dia NRV (Non Returnable Valve) nozzle compatible with epoxy injector and having machined external end to receive outlet of Grouting Gun. Fix inside the hole by applying thixotropic epoxy adhesive to ensure complete sealing and allow curing the system for minimum of 8 Hrs before Grouting including nozzle projections, excess putty, if any, over concrete element by grinding, leveling and finishing the external surface, after completion of the work, etc. complete all as specified and as directed by Engineer-in-charge. |
| 102 | Grouting, injecting two part, low viscosity, moisture insensitive injection liquid, based on high strength epoxy resin by pressure and using pressure epoxy injector with accessories till nozzle refused to accept the grout including mixing of grout having following properties:- (i) Mixed Density 1.1 kg/l (at +27°C); Viscosity ~ 250 mPas at +30°C and should comply according to ASTM C 881, Type II and IV, Grade-1, Class E+F (ii) Compressive strength >= 70 N/sqmm (7 days) according to ASTM C 579; Tensile Strength ~ 50 N/sqmm (after 7 days at +30°C cure) (According to ASTM D 638); Tensile Modulus ~ 2000 N/sqmm (after 7 days at +30°C cure) (According to ASTM D 638); (iii) Bond Strength ~ 10.8 N/sqmm (failure in concrete) after 14 days at +30°C cure; Flexural strength ~ 50 N/sqmm according to ISO 178. (iv) Seal the nozzle with thixotropic epoxy adhesive after the refusal of grout material from the nozzle. Note:- leakage through other nozzle or cracks are required to be monitored while grouting and such points to be sealed as and when required without any extra cost complete all as specified and as directed by Engineer-in-charge.Note :- Mode of measurement: per kg of material consumed Make: Sika - SikaDur 52 LP/ Fosroc- Conbextra EP 10/ Pidilite Dr Fixit Epoxy Injec |
| 103 | Material and labour for Chipping of slab/columns/beams/chajjas/parapet/roof projection/balcony/staircase and removing loose mortar with chisel hammer without much impact on concrete surface, clean the surface by sand blasting the surface using river sand with minimum of 6 kg pressure at the nozzle or air blow by electric pressure blower by mechanical compressor, cleaning the exposed reinforcement with wire brushes etc and disposal of debris for all lead and lifts, complete all as specified and directed |
| 104 | Material and labour for Cleaning & applying rust remover in two coats over rusted reinforcement surface and providing anti corrosive coating with two component epoxy based zinc rich primer/Rust passivation Inhibitor coat at the rate of 6-8 sq. mtr/ltr not less than 50 microns dft with Sika friazinc R or equivalent to reinforcement surface as per manufacturer’s instructions including all scaffolding, machinery, tools tackles and clearing of debris complete all as specified and as directed by Engineer-in-Charge. Make:- Mentioned in Appx 'B' |
| 105 | Material and labour for Shear Connectors by drilling 12mm dia holes up to a depth of 75mm maximum and fixing 8mm dia L shaped anchor rods as shear connectors at every 300mm c/c on the surfaces of the columns/beams/slab or any other structural member as the case may be. Clean the same using air or blower and make sure that there are no fine particles present in the hole and filled the holes with one or two component styrene free vinyl ester resin anchor or two components, styrene & cement free epoxy- acrylate fixing and anchoring compound. At this stage push the shear connector gently in to the hole and finish the excess resin which comes out of the hole and allow the shear connectors not to be disturbed for Minimum 20 minutes complete all as specified and as directed by Engineer-in-Charge. Make:- Mentioned in Appx 'B' |
| 106 | S & F of new steel or rebar’s by drilling holes with 10 mm to 20mm dia and 100 to 200mm deep as per IS code of 10D formula and filling the holes after inserting of reinforcement dia 8 to 16mm for anchoring at ends/shear connector and filled the holes with one or two component styrene free vinyl ester resin anchor or two components, styrene & cement free epoxy acrylate fixing and anchoring compound (having the technical parameters mentioned in material specifications) using standard sealant applicator gun after drilling holes of required diameter at required locations, for holding / fixing / placing in position the steel mesh reinforcement at desired level/ stretching complete all as specified and as directed by Engineer-in-Charge. Make:- Mentioned in Appx 'B'(Note : Steel/reinforcement shall be paid and measured separately). |
| 107 | Material and labour for providing pourable, shrinkage compensated, free flowing and self-compacting superior performance micro concrete Sikacrete 145IN factory design with selected cement, aggregate and other chemicals. Recommended water and coarse aggregate maximum 15% of bag to be added at site as per manufacturer instruction. Product should strictly meet the requirement of Compressive strength @28 days ~50 N/mm2 (ASTM C109)/ Flexural strength @28 days ~7 N/mm2 and Tensile adhesion strength @≥ 2 N/mm2 (28 days, +30 °C) (EN 1542) or as per manufacturer instructions and mixing concrete with mechanically electrically operated mixer machine Including necessary formwork , Shuttering and jacating etc all as specified and directed. Make:- Mentioned in Appx 'B' |
| 108 | Material and labour for applying bond coat on the prepared old surface of concrete/masonry to receive new polymer mortar/polymer modified mortar or micro concrete with two coats of Sika-Latex Super SBR or equivalent as per manufacturer specifications. Laying of reinstatement polymer mortar or micro concrete shall be completed within the overlay time of bonding coat. This bond coat act as bonding agent between old and new concrete Make:- Mentioned in Appx 'B' |
| 109 | Material and labour for applying to the damaged concrete portion of slab/ columns/ beams/ chajjas/ parapet / roof projection/ balcony/ staircase with single component, fiber reinforced, dual shrinkage- compensated thixotropic, cementitious ptch repair mortar Sika monotop 122F (having the technical parameters mentioned in material specifications) capable of applying up to 20-25mm thick in double layer initially by hand and finishing with troweled carefully compacting the same around the rebar and finishing to bring it in line with existing concrete surface with an average specified thickness. Make:- Mentioned in Appx 'B' |
| 110 | Material and labour for Efflorescence treatment to exiting masonry wall complete all as directed and as per following steps and using materials:-1. STEP 1 - The seepage area from outside & inside shall be marked [consider at least 300mm extra area all around]. Old plaster along with brick joint mortar upto 15mm depth shall be removed by mechanical means.2. STEP 2- After removing of plaster, thorough cleaning shall be carried out by clean water.3. STEP 3 - The pointing of brick joints shall be carried out by polymer modified mortar Sika MonoTop®-122 F (Compressive strength ≥ 50 MPa in 28days as per ASTM C 109 -7cm cube) along with a bonding primer made by Sika Latex® SBR (Tensile adhesion strength - ≥ 1.5 N/mm2 (concrete failure) as per EN 1542)4. STEP 4 - The fixing of NRV nozzles shall be carried out in a straight line near to old DPC followed by sealing of nozzles as well as a layer of 12-15mm thick polymer modified mortar shall be applied by Sika MonoTop®-122 F ((Compressive strength ≥ 50 MPa in 28days as per ASTM C 109 -7cm cube) along with a bonding primer made by Sika Latex® SBR Tensile adhesion strength - ≥ 1.5 N/mm2 (concrete failure) as per EN 1542). Allow mortar to cure for 24 hours.5. STEP 5 - Next day, start injecting the poly acrylic injection Sika Injection®- 306 (with a versatile and adjustable reaction time having mixed viscosity: 3-11 M pa s at + 20 degree C, reaction time: adjustable according to ambient temperature and execution requirement between 8-50 Mins PH - 9-10. Tested as per Wissbau No 2002- 094- (1A) function test with re- injectable hose system) through NRV nozzles and allow product to react so that a seal can be created within the brick work.6STEP 6 - Once the injection work is completed, cut the NRV nozzles and seal with polymer modified mortar.Apply two coats of SikaTop®-107 Seal Plus IN ( Food grade product - CFTRI Certificate for repeated use with aqueous foods / water as per USFDA 175.300 , Tensile adhesion strength ≥ 2.0 N/mm2 as per ASTM D4541 & Water penetration under pressure ~0 mm penetration at 5 bar for 72 h as per BS EN 12390-8) followed by protect it with polymer modified mortar made by Sika Latex® SBR (Tensile adhesion strength - ≥ 1.5 N/mm2 -concrete failure- as per EN 1542).Make : Sika or Techno commercial equivalent in make mentioned in Appx 'B' approved by CWE |
| 111 | Material and labour for complete removal of existing treatment of any type/description from external/internal wall/ceiling surfaces, soffits/chajja/roof projection surfaces etc., by Mechanical sander/grinder machine having suction vaccum Bag (Smart periodical methodology), complete all as specified and as directed by Engineer-in- charge. |
| 112 | Material and labour for new plastered surfaces and prepared surface after complete removal, applying acrylic wall putty in internal/external walls/RCC surfaces/soffits of chajjas/roof projections/cantilevers/balcony/ceilings etc (thickness vary from 1.5 to 2.5 mm as required for desired smoothness and levelling of surfaces in two or more layers) by using ready made wall care putty including sand papering after filling the putty to make surface smooth and ready for receiving interior/exterior painting complete all as specified and directed.Notes : (i) The prepared surface after wall putty, the contractor will inform to the GE as well as to the Engineer-in-Charge for site inspection before applying further external finishes. Please note that the further external finishes work will start only after approval of the prepared surface from the GE as well as to the Engineer-in-Charge through site order. |
| 113 | Material and labour for Preparation and applying 02 coats of interior emulsion paint (light shade) @ 12 sq.m/litre/2 coats by using spray gun to wall surfaces over & including a coat of interior wall primer @ 10 sq.m/litre/1 coat as recommended for under coat by manufacturer of interior emulsion and primer brands complete all as specified and directed. |
| 114 | Preparation of surfaces and applying 02 coats of exterior emulsion paint (light shade) with highlighter of any approved shade, @ 5 sq.m/litre/2 coats by using roller to external walls/RCC surfaces/soffits of chajjas/roof projections/cantilevers/balcony etc surfaces over & including a coat of exterior wall primer @ 11 sq.m/litre/1 coat as recommended for under coat by manufacturer of exterior emulsion by using following brands of emulsion and primer complete all as specified and directed. |
| 115 | M&L for complete removal of existing surface finishes of ceiling and applying two coat of interior emulsion on old plasterd ceiling surfaces etc complete all as specified. |
| 116 | M&L for 30 cm x 30 cm x (20 to 25) mm thick chequered cement concrete tiles(rubber moulded) set jointed and pointed in neat cement slurry in floors with grey cement including 15mm thick screed in CM 1:6 with pigments complete all as specified and directed by Engineer-in-Charge. |
| 117 | M&L for door seal not less than 40mm fixed with stainless steel screws at the bottom of the door shutters complete all as specified. |
| 118 | M& L for providing and fixing stainless steel (Grade 304) railing made of Square hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) & Providing baluster and necessary fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement. |
| 119 | S&F in repair 15 mm dia borelong body bib taps cast copper alloy with on/off handle, screwed down, screwed for iron pipe, or for brass ferrule complete all as specified and as directed. |
| 120 | Supply and fixing in replacement 600mm x 450mm size bevelled edge mirror of selected quality glass mounted on 6mm thick commercial ply and fixed to wooden plugs with chromium plated brass screws and cup washers, including fancy type PVC decorative beading, complete all as specified and directed by Engineer-in-Charge. |
| 121 | S&F in repairs cabinet of PTMT with looking mirror of size 450x600mm complete all as specified and directed by Engineer-in-charge. Cat Part No. 555 of Prayag or equivalent in Polytuf/Shakti |
| 122 | S&F CP angle valve for 15 mm bore pipe with capstan head long screwed shank including cp cover plate fancy type fixed as in repair. Make: Cat NoG5207A1 of Claret Collection of Parryware or equvailent from other specified makes |
| 123 | S&F PVC connection 450 mm long suitable for 15 mm bore GI pipe including CP brass nuts on both sides, complete, all as specified. |
| 124 | S&F toilet paper holder, brass chromium plated (Cat Part No T6005A1 of make Parryware or Cat part No. 21751 of Jaquar or equivalent from Marc/Somany/ Parko/Gem/Prayag), fixed to walls with chromium plated (CP) brass screws complete. |
| 125 | S&F CP brass soap dish of fancy type, all as approved. Make: Jaquare Cat Part No 21731of make of Jaquar or equivalent from Parryware/Marc/Somany/Parko/Gem/Prayag. |
| 126 | S&F glass corner self assembly, fancy type, made of 5 mm thick sheet toughened glass of size 250x250mm, fixed with CP brackets, complete, all as specified and directed. |
| 127 | S&F 5 mm thick and 450 mm long glass shelves fancy type and fixed over CP brass brackets all as specified and directed by Engineer-in-charge. |
| 128 | S&F PTMT grating 125mm dia with waste hole (Minimium weight 40 grams) |
| 129 | S&F PTMT grating 100mm dia without hole (Minimium weight 25 grams) |
| 130 | Taking down carefully aluminium point wiring (light, fan, socket or power, bell complete fitting such as sockets, ceiling roses, pendants, batten holders, regulators and making good the disturbed surfaces of wall, floors, ceiling in CM 1:3 etc complete all as specified and directed by Engineer - in - Charge. |
| 131 | M & L for concealed point wiring for one socket out let 5/6 amps point controlled by one switch(on independent board) (using red,black and green colour wires as colour coding i.e for phase,neutral,earth wire etc) complete with 2.5 sqmm nominal cross section area) single core FRLSH PVC insulated unsheathed and multi strand copper conductor cable 1100 volt (ISI marked) drawn through and including PVC conduit 20mm dia(medium duty ISI marked) with all fittings and all accessories i.e. pipe bend, pipe hook,elbow,junction boxes etc,including pressed steel powder coated sunkeen terminal box suitable for modular switch socket (min 50mm deep and 1.6mm thick sheet, suitable size) concealed in wall, including inner and outer plates (cover plate) suitable for fixing the modular switch/ socket, including provn of 2.5 sqmm single core FRLSH PVC insulated multi strand copper conductor wire continues as earth wire connected to earth dolly etc. including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc. by using CM (1;3) including fixing of switch,socket complete all as specified and as directed. |
| 132 | All as per Srl item No -02 here in before but for one switch socket combination 5/6 amp on independent board complete all as specified and directed by Engineer - in - Charge. |
| 133 | All as per Srl item No -02 here in before but for one three pin socket outlet 5 Amp on same board with other switches complete all as specified and directed by Engineer - in - Charge. |
| 134 | All as per Srl item No. 2 here in before but for one switch socket combinationt 6 pin 5/ 15 Amps on independent board with copper conductor 4 Sqmm complete all as specified and directed by Engineer - in - Charge. |
| 135 | All as Srl item No. 02 here in before but for one light point controlled by two 2 ways switches complete all as specified and directed by Engineer - in - Charge. |
| 136 | All as Srl item No. 02 here in before but for call bell point complete all as specified and directed by Engineer - in - Charge. |
| 137 | S & F modular switch 5/6 Amps single pole one way,one module including modular cover plate with frame and metal flush box complete all as specified and directed by Engineer - in - Charge. |
| 138 | S&F of module switch 1 way 16 A, 1 module complete all as specified & directed by Engineer - in - Charge. |
| 139 | S&F of modular socket, 6/16 Amps, 2/3 pin combined 2 module complete all as specified & directed by Engineer - in - Charge. |
| 140 | S & F modular switch 5/6 Amps single pole two ways complete all as specified and directed by Engineer – in - Charge. |
| 141 | S & F modular socket outlet 5 pin 5 Amps flush type complete all as specified and directed by Engineer - in - Charge. |
| 142 | Supply and fix in replacement industrial socket metal clad plug and socket with MCBs single pole 20 Amp complte all as specified and directed by Engineer - in - Charge. |
| 143 | S&F modular bell push 5 Amp complete all as specified and directed by Engineer – in - Charge. |
| 144 | S & F modular stepped type, fan regulator not less than 120 watt for ceiling fan 1200/1400mm sweep complete all as specified and directed by Engineer - in - Charge |
| 145 | S&F Buzzer AC 230 single poleVolt ding dong type complete all as specified and directed by Engineer - in - Charge. |
| 146 | S & F ceiling rose surface bakelite three terminals complete all as specified and directed by Engineer - in - Charge. |
| 147 | S & F in replacement of existing light fitting with LED batten with aliminium housing and integrated electronic driver, 20 watt having input voltage AC90-300V, 50 Hz , 6500K, and all other accessories including connection with flexible cable copper conductor twin core of size 23/.2 mm upto ceiling rose/connector complete all as specified and directed by Engineer - in - Charge. |
| 148 | S&F in replacement security light fitting LED TYPE 25 watt with all necessary acessories, Clear transparent acrylic cover, prewire suitable to operated on 230 volt 50 HZ AC & Supply and fixing to wall / on pole including fixing arrangement with suitable galvanized iron pipe 35 mm bore “light grade” brackets 2 mtr length bent to shape to obtained required shape including clamps, nuts / bots / washers etc connecting with suitable flexible copper wire of size 23/0.0076 complete all as specified and directed by Engineer - in - Charge |
| 149 | S&F in replacement decorative wall light,brushed nickle finish fixture with OPAL glass diffuser including 9 watt LED filament lamp E14 base complete all as specified and directed by Engineer - in - Charge. |
| 150 | S & F in replacement LED Bedside Light (White,3000k) 3 Watt, with flexible arm suitable for reading complete all as specified and directed by Engineer - in - Charge. |
| 151 | S & F in replacement Water tight bulk head fitting,comprision of connector galvanised cast iron back plate,weather proof enamelled gallery ,glass well,and including 10 watt LED lamp all as specified and directed by Engineer - in - Charge |
| 152 | S & F in replacement compact & decorative energy efficient LED mirror light fitting with antiglare diffuser and decorative end caps suitable for 1X10 watt fitting 2 ft version including LED lamp 10 watt complete all as specified. |
| 153 | S & F in replacement angle holder insulated body with back plate for conduit fittings complete all as specified and directed by Engineer - in - Charge |
| 154 | S&F in replacement LED lamp 9W for angle holder complete all as specified and directed by Engineer - in - Charge. |
| 155 | S & F in replacement of sub-main wiring with PVC insulated and un-sheathed 4 x 6.00 sqmm (Nominal Area) FRLSH stranded copper conductor drawn in and including PVC \\"medium quality\\" conduit as per size required including 2 x 6Sqmm (Nominal area) copper cable as earth contiunity conductor after chasing in wall and making good the disturbed surfaces and white wash or existing colour , necessary junction box and covers including necessary connections, PVC flexible pipes are used in pannel board while connecting the cable complete all as specified and directed by Engineer-in-Charge.(Note : PVC cable and PVC conduit shall be ISI marked) Note :- Four length of 6 Sqmm cable and two length of 6 Sqmm earth cable along with PVC conduit will be measured as one running length |
| 156 | S&F in replacement sub main two single core PVC copper conductor unsheathed wire multi stranded 4 sqmm FRLSH including cutting chasing and grouting PVC pipe including Tee, Elbow, Bend etc and including 4.0 sqmm copper conductor single core wire connected by common earth all as specified. Including 20 mm dia concealed PVC conduit, medium grade, ISI marked complete all as specified and directed by Engineer-in-Charge.Note :- Two lengths of 4.0 sqmm cable and one length of 4.0 sqmm earth cable along with PVC conduit will be measured as one running length |
| 157 | S&F in replacement Sheet metal enclouser for doble door Vertical DBs made out of CRCA mild steel sheet surface with insulated material like polyester with epoxy powder coated surface mouting VTPN 4 Way 415 Volt ISI marked 250Amps busbar stove enameled dust and vermin proof,IP:43 protection suitable for incorporation FP MCCB(V-Tech) N3 Frame upto 250A ,Isolators and including give connection with wire and cable etc complete all as specified and directed by Engineer-in-Charge. |
| 158 | S&Fin replacement MCCB 4 pole 63 Amps with breaking capcity 16kA ,Fixed TM and 415 volts AC Supply ISI marked complete all as specified and directed by Engineer - in - Charge. (Make -Indo Asian/Havells / Legrand) |
| 159 | S & F in repairs sheet metal enclosure for double door DBs made out of CRCA mild steel sheet surface with insulated material like polyester with epoxy powder coated surface mounted TP & N 4 ways, 415 Volts, ISI marked 200 amps bus bar stove enameled dust and vermin proof suitable for incorporation MCBs and isolators etc complete all as specified and directed by Engineer - in - Charge. (Make - Havells / Legrand / Indo Asian) |
| 160 | S & F in replacement MCB ‘B’ series type suitable for 415 volts, 10 KA, AC supply 40 Amps, triple pole and neutral (TPN) with over load and short circuit protection and rupturing capacity not less than 10KA complete all as specified and directed by Engineer - in - Charge. (Make - Havells / Legrand / Indo Asian) |
| 161 | S & F in replacement MCB ‘B’ series type suitable for 415 volts, 10 KA, AC supply 63 Amps, triple pole (TP) with over load and short circuit protection and rupturing capacity not less than 10KA complete all as specified and directed by Engineer - in - Charge. (Make - Havells / Legrand / Indo Asian) |
| 162 | S & F in replacement MCB ‘B’ series type suitable for 240 volts,10 KA, AC supply 6 to 32 Amps , single pole (SP) with over load and short circuit protection and rupturing capacity not less than 10KA complete all as specified and directed by Engineer - in - Charge. (Make - Havells / Legrand / Indo Asian) |
| 163 | M & L for Earthing complete with GI earth plate electrode 60 cm x 60 cm x 6 mm thick burried directly in ground (earth pit not less than 2.25 Mtr deep below ground level ) with top edge of plate not less than 1.5 Mtr below ground level , connecting to GI earth lead 4 mm dia GI earth wire ,by means of bolts,nuts and washers of GI and protection by provision of GI medium grade pipe 15 mm bore including provision of concrete pit in PCC (1:2:4) type B1 using 20 mm grade stone aggregate with 40 mm thick cover of RCC (1:2:4) reinforced with XPM (weight not less than 4 gs /Sqmm ) and frame of angle iron 25mmX25mmX6mm with lugs 02 Nos and with 6 mm dia MS bar handle made to shape ,GI light grade 20mm bore pipe for watering perforated at the bottom 1.75 meter long placed ontop edge of earth plate common salt and charcoal filling test point made out of 40 mmX 8 mm FI with fixing arrangement ,funnel, wire mesh and earth work inhard dense soil ,returning filling in and removal of surplus soil to a distance not exceeding 50 mtrs all as per electric plate no.3 of SSR part 1 and connecting to earth test point including taking out unserviceable earthing with all acessories all as specified or indicated including testing on completion all as specified and directed by Engr -In - Charge |
| 164 | S&F Heavy duty metal body exahust fan of 300mm sweep ,240 volt,copper winding, complete with louvers and shutter and mounted in suitable opening arrangement in wall and connecting up including 3 core PVC insulated PVC sheathed copper conductor flexible cable 24/0.2mm from ceiling rose to fan complete including breaking of brick wall and making a hole for fixing of exhaust fan including grouting of bolts and making good to distubed wall in cement mortar (1 :4) white washing matching with existing colour etc. |
| 165 | S&F exhaust fan made of sturdy engineering plastic of 250mm sweep ,240 volt, complete with louvers and shutter and mounted in suitable opening arrangement in wall and connecting up including 3 core PVC insulated PVC sheathed copper conductor flexible cable 24/0.2mm from ceiling rose to fan complete including breaking of brick wall and making a hole for fixing of exhaust fan including grouting of bolts and making good to distubed wall in cement mortar (1 :4) white washing matching with existing colour etc. (Make : Havells/Orient/Crompton). |
| 166 | Taking down fan, sealing cable end, dismantling blades and removing fan and blades to store |
| 167 | M & L for Painting of ceiling fans complete, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc. |
| 168 | Hanging only ceiling fan (M.D. supply) and connecting up including provision of cable from ceiling rose or connector to fan. |
| 169 | S&F ceiling fans AC single phase 230/240 V of size 1200 mm sweep without regulator having Min air delivery 210 CFM with service value 6.00 BEE 5 star rated with brushless direct current motor (BLDC) complete with electrical connection providing three core round flexible copper conducter cable of suitable size complete all as specified and directed by Engineer-in-charge. |
| 170 | Taking down carefully water heater (geyser) and refixing them after rapairing and painting with proper connection all as directed by Engr-in-Charge. |
| 171 | Supply and fix electric water heater, storage type ABS/Plastic + sheet metal body with glass coating MS tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc |
| 172 | Supply and fix electric water heater, storage type ABS/Plastic + sheet metal body with glass coating MS tank and heating element upto 2 KW capacity 50 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc |
| 173 | Supply, fixing ,testing & commisioning of electric chimney (90 CM) with feature of filterless & autoclaean technology,oil collector tray, inbuilit light, digital display, noise level, 46 dB, 304W motor capacity with copper winding, extra installation kit, air suction capacity 1400 cum/h , , input vol 220-240 V/50Hz, and fitting in wall as connecaled or duct all as specified and directed by Eng-in-Charge. Make : KutchinaNote :- Fixing arranges with PVC pipe included |
| 174 | S & F 400 mm wall mounted fan complete all as specified and directed by Engineer - in - Charge. |
| 175 | Supply and fix 3 pin telephone socket RJ 11 with metal flush box having holes for 20 mm conduit entry for telephone connection all as specified and directed by engineer in charge. |
| 176 | S & F Rigid non-metallic PVC conduit 20 mm dia inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. |
| 177 | Material and labour for extra wiring for inverter socket out going to switch board/DB with 2.5 Sqmm single core, FRLSH PVC (using colour coding as directed) insulated multistrand copper conductor drawn through existing conduit (conduit for point wiring already catered in point wiring item of BOQ) including making connection to switch board/DB and inverter socket) complete all as specified and as directed by Engineer-in-charge. |
| 178 | Supply and fixing plug top 5/15 Amp 3 pin good quality suitable for 240 volts, AC supply for inverter socket complete all as specified and as directed by Engineer-in-charge. |
| 179 | Excavation in trenches not exceeding 1.5 mtr wide and not ecxceedinf 1.5 mtr depth for laying of cables complete all as directed |
| 180 | Returning filling in including spreading levelling watering and well ramming in layers not exceeding 25cm complete all as directed |
| 181 | Removal of Excavated material n exceeding 50 mtr and depositing where directed |
| 182 | Supply and laying DWC pipe of outer dia size 90 mm for laying of Lt cable complete all as specified and as directed. |
| 183 | Supply and lay jointing and testing and commissioning in replacement of 50 Sqmm x 4 core XLPE insulated, screened , PVC bedded galvanised steel strip or wire armoured electric power cable heavy duty multi stranded aluminium conductor & PVC sheathed LT cable 1100 V grade conforming to IS-7098 laid in trenches/ducts/fixed on poles wall/laid under roads/paths/drain/culverts or passing through pipes complete all as specified and directed by Engineer-in-Charge. |
| 184 | Supply and lay GI pipe 50 mm light grade for cable protection in walls trenches or any situation including clamp nut bolt etc complete all as specified and directed by Engineer-in-Charge. |
| 185 | Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine for laying of DWC pipe of outer dia 90 mm complete all as specified. |
| 186 | Supply and laying GI pipe medium grade ISI marked 25mm dia including all fittings in old/new position as directed by Engr-in-charge. |
| 187 | Supply and Fixing 20 mm boreGI pipe medium grade ISI marked including all fittings on wall or laid on floor in old/new position as directed. |
| 188 | -do- but 25 mm bore |
| 189 | M & L cutting existing GI water turbing of size 25 mm bore for alternation or addition including screwing/threading and jointing with suitable size GI socket complete all as specified and as directed by Engineer-in-Charge. |
| 190 | Supply and Fixing Gun Metal gate valves with iron wheel head,screwed 25 mm both ends for iron pipe,ISI marked, as per IS: 778 complete all as specified. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail