Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Lump sum price worked out by the contractor for \\"BUILDING WORKS\\" as listed in Schedule ‘A’ Part-I representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES |
| 2 | Lump sum price worked out by the contractor for \\"INTERNAL WATER SUPPLY \\" as listed in Schedule ‘A’ Part-II representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES |
| 3 | Lump sum price worked out by the contractor for \\"INTERNAL ELECTRIFICATION\\" as listed in Schedule ‘A’ Part-III representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES |
| 4 | Lump sum price worked out by the contractor for \\"ROAD, PATH, CULVERT AND HARD STANDING\\" as listed in Schedule ‘A’ Part-IV representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES |
| 5 | Lump sum price worked out by the contractor for \\"SEWAGE DISPOSAL\\" as listed in Schedule ‘A’ Part-V representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES |
| 6 | Lump sum price worked out by the contractor for \\"AREA DRAINAGE \\" as listed in Schedule ‘A’ Part-VI representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES |
| 7 | Lump sum price worked out by the contractor for \\"COMPOUND WALL ,FENCING AND GATE \\" as listed in Schedule ‘A’ Part-VII\\" representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES |
| 8 | Lump sum price worked out by the contractor for \\"RAIN WATER HARVESTING\\" as listed in Schedule ‘A’ Part-VIII representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price of prepriced by the MES |
| 9 | Lump sum price worked out by the contractor for \\"EXTERNAL WATER SUPPLY\\" as listed in Schedule ‘A’ Part-IX representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price of prepriced by the MES |
| 10 | Lump sum price worked out by the contractor for \\"EXTERNAL ELECTRIFICATION\\" as listed in Schedule ‘A’ Part-X representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price of prepriced by the MES |
| 11 | Lump sum price worked out by the contractor for \\" LIGHTING PROTECTION \\" as listed in Schedule ‘A’ Part-XI representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES |
| 12 | Lump sum price worked out by the contractor for \\"FIRE FIGHTING\\" as listed in Schedule ‘A’ Part-XII representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price of prepriced by the MES |
| 13 | Lump sum price worked out by the contractor for \\"LIFT WORK\\" as listed in Schedule ‘A’ Part-XIII representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price of prepriced by the MES |
| 14 | Lump sum price worked out by the contractor for \\"DG SETS SUPPLY\\" as listed in Schedule ‘A’ Part-XIV representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price of prepriced by the MES |
| 15 | Lump sum price worked out by the contractor for \\"DEMOLITION AND DISMANTLING WORK\\" as listed in Schedule ‘A’ Part-XV representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price of prepriced by the MES |
| 16 | Lump sum price worked out by the contractor for \\"SITE CLEARANCE, SITE DEVELOPMENT AND EARTH WORK\\" as listed in Schedule ‘A’ Part-XVI representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES |
| 17 | Sch 'A' Part-XVII MISC ITEMS (TO BE QUOTED BY CONTRACTOR) Notes: (i) This schedule is not pre-priced by MES and the pre-priced rate indicated as \\"Rs 0.00\\" under column 5 signifies this fact only. (ii) Excavation and earth work except for the items which categorically includes for same shall be measured and paid separately under SCH A PART-XVI SITE CLEARANCE, SITE DEVELOPMENT AND EARTH WORK schedule). |
| 18 | INTERNAL WATER SUPPLYS&F for two way bib cock with wall flange quarter turn (Low-flow) 15/16 mm dia. etc complete all as specified and directed by Engineer-in-Charge |
| 19 | S&F CP wall mixer of Bathroom 3 in 1 system with provision for both hand & over head shower with 115 mm long bend pipe cinnecting legs & wall flange etc complete all as specified & as direcetd. |
| 20 | S & F Gun-metal, globe or gate valves, painted finish with forged brass handle and iron wheel head, screwed both ends internally IS:778 class 2 for iron pipe or for unions of size 80mm dia complete all as specified and directed. |
| 21 | INTERNAL ELECTRIFICATIONS&F for RG6 cable for TV point etc complete all as specified and directed |
| 22 | S&F for modular type 1 module co-axial type TV socket etc complete all as specified and directed |
| 23 | S&F for modular type 1 module RJ-11 telephone socket with shutter etc complete all as specified and directed |
| 24 | S&F for modular type 1 blanking plate etc complete all as specified and directed |
| 25 | S & F for lamp holder including Highly efficient LED Bulbs, 9 watt insulated body with back plate suitable for batten fittings etc complete all as specified and directed. |
| 26 | ROAD, PATH, CULVERT AND HARD STANDINGM&L for Single RCC Hume pipe 600 mm dia culvert with PCC (1:4:8) in foundation, RCC hume bedding in (1:4:8), brick masonry in CM (1:4) including coping etc including necessary earthwork in soft/loose soil etc complete all as specified and directed . |
| 27 | SEWAGE DISPOSALS&F for DWCPE (SN8) 180mm outer dia and 163 inner dia of pipe for depth 0.70mm to 1.65m, laid on 150 mm thick bed (1:4:8) with excavation in any type of soil including manholes/drop manhole of standard size made of brick mosonary /RCC/Precast RCC with SFRC ventilating cover and frame,includes all items and activities to execute and make sewer line functional etc complete all as specified and directed. |
| 28 | S&F for DWCPE (SN8) 200mm outer dia and 175 inner dia of pipe for depth 0.70mm to 1.65m, laid on 150 mm thick bed (1:4:8) with excavation in any type of soil including manholes/drop manhole of standard size made of brick mosonary /RCC/Precast RCC with SFRC ventilating cover and frame,includes all items and activities to execute and make sewer line functional etc complete all as specified and directed. |
| 29 | S&F for DWCPE (SN8) 300mm outer dia and 260 inner dia of pipe for depth 1.65mm to 2.3m, laid on 150 mm thick bed (1:4:8) with excavation in any type of soil including manholes/drop manhole of standard size made of brick mosonary /RCC/Precast RCC with SFRC ventilating cover and frame,includes all items and activities to execute and make sewer line functional etc complete all as specified and directed. |
| 30 | BOREWELL FOR RAIN WATER HARVESTING(a) Provision of trail bore by drilling with reverse rotary system upto 400 mm bore upto 52 m depth incl all works pertaining to boring complete in all respect in aluvium soil/ strata incl hard stone / boulder etc.(b) M&L for 200 mm bore CPVC pipe assembly jointing, lowering in any position upto the reqd depth below given level incl jointing the pipe by solvent & screwing 04 Nos screws in each joint complete.(c) Ditto as item 30(b) above but slotted pipe(d) M& L for packing with Pea gravel of 4.6 mm to 8mm size of approved quality as ordered to pack arround the casing / slooted pipe in borewell complete.(e) M&L 25 mm bore perforated CPVC pipe 52 mtr long for vent pipe etc complete all as specified and directed. |
| 31 | ARBORICULTURELaying of lawns including ploughing leveling breaking of clods manuring & removal of stones etc. (cost of manure or extra good earth to be paid separately) Maintenance of lawns for 30 days more till the grass forms a thick lawns free from weeds & fit for moving in the duration of planting if lawn die some where the contractor will replant it at his own cost. In rows 5 Cms. Apart in either direction etc complete all as specified and as directed. |
| 32 | Supply of different flowing plants 900mm to 1500mm height and age of the plant at site including loading / unloading & transportation etc complete all as specified and as directed. |
| 33 | Supply of different varieties of shrubs 600mm to 900mm height and age of the plant at site including loading / unloading & transportation etc complete all as specified and as directed. |
| 34 | Supply of Different varieties of climbers 900mm to 1500mm height and age of the plant at site including loading / unloading & transportation etc complete all as specified and as directed. |
| 35 | Supply of different varieties of palms in polyethylene bags / earthen pots according to height growth & age of the plant at site including loading / unloading & transportation etc complete all as specified and as directed. |
| 36 | Supply & planting of shady plants (Neem, Peepal, Goolar, Jamun, Imli or other specified) along including the following activities :-(a) Preparation of soil including & removing of unwanted shrubs removal of stones & garbage.(b) Supply of plant at site of two years of age & height more than 1.50Mtr.(c) Supply of dry manure (Farm yard manure organic).(d) Supply of insecticides.(e) Digging of pits size 60x60x60 Cms. including removal of stones, Manu-ring application of insecticides & watering at least 15 Liter per plant after planting.(f) Watering to plants. |
| 37 | Supply & planting of ornamental plants (Kachnar, Amaltas, Gulmohar, Arjun, Jacranda etc. or other specified) along including the following activities :-(a) Preparation of soil including & removing of unwanted shrubs removal of stones & garbage.(b) Supply of plant at site of two years of age & height more than 1.50Mtr.(c) Supply of dry manure (Farm yard manure organic).(d) Supply of insecticides.(e) Digging of pits size 60x60x60 Cms. including removal of stones, Manu-ring application of insecticides & watering at least 15 Liter per plant after planting.(f) Watering to plants. |
| 38 | EXTERNAL WATER SUPPLY 'Supply, lay, commissioning, jointing and testing of centrifugally cast (spun) ductile iron pipes of 100mm bore class K-9 with spigot and socket ends conforming to IS 8329/2000, IS: 12288 : 1987 code of practice for laying in trenches complete all as specified and directed.Note: The rate quoted by contractor are inclusive of all type of Joints. |
| 39 | Supply, lay, commissioning, jointing and testing of centrifugally cast (spun) ductile iron pipes of 250mm bore class K-9 with spigot and socket ends conforming to IS 8329/2000, IS: 12288 : 1987 code of practice for laying in trenches complete all as specified and directed.Note: The rate quoted by contractor are inclusive of all type of Joints. |
| 40 | Supply and fix CI foot valve with leather washer, of size 100 mm , lift and swing, single door, IS 4038 marked one with each pump suction line complete all as specified and directed. |
| 41 | Supply & install pumping sets, centrifugal, monolock type of head not less than 60 mtr , and discharge 462 LPM electric driven, of capacity not less tha 15 HP etc complete all as specified and directed. (for ORs and JCOs Qtr 05 Running and 5 Standby) |
| 42 | Supply & install pumping sets, centrifugal, monolock type of head not less than 40 mtr , and discharge 642 LPM electric driven, of capacity not less tha 10 HP etc complete all as specified and directed. (for Offers Qtr 01 Running and 01Standby) |
| 43 | S&F for heavy duty chemical dosing systemplunger typesuitable to injectsolution up to 25 LPHworking pressure10 kg/cm2 comprising dosing pump coupledwith three phase electricmotor of capacity0.5 HP , 1440 RPM assembly with agitatorinone motor, agitator with SS sweep bladeduly FRP coated, FRP tank 150 Ltr capaity, completed unit mounted on heavy duty MS fabricated frame duly anti corrosive paint complete with chemical grade PVC NRV, along with control panel for Dosing pump suitable for SSAPS/CDSPT/25 made of powder coated MS febricated box consisting of LED indicator, digital volt meter, Amp Meter, single phase preventer, Highvoltage low voltage protection etc complete all as specified and directed. |
| 44 | M& L for cutting of existing pipeline of upto 200 mm dia for taking branch connection along with insertion of Tee and connecting material such as joint, nut bolts, as required at site etc complete all as specified and directed. |
| 45 | Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure.etc complete all as specified and directed. |
| 46 | M&L for construction of valve chamber of brick masonry from the top of surface with MS covers 3.15 mm thick and 40x40x6 mm MS angle with hinges for locking arrangement including excavation and earth works PCC (1:3:6) type C2 for foundation PCC bed/coping in cement concrete (1:2:4) type B1, plastering in CM 1:3 painting with two coats of synthetic enamel paint over a coat of red oxide primer for the size of chamber 900 mm x 900 mm x 900 mm (internal dimention) all as per TD drg No TD/2004/26 sheet No 1/3 tp 3/3 etc complete all as specified and directed. |
| 47 | Supply, installations, testing and commissioning of factory made LT panel indoor type, dust and vermin proof totally enclosed , fabricated out of steel sections, the door opening shall not be less than 150 degree. The construction of panel board shall be dust, vermin proof, IP 54 standard double shutter gears front and rear frame work and 2.0 mm thick MS sheet duly powder coated made of 40 x 40 x 6 mm thick angle iron frame including necessary PCC work all as specfified suitable for 415 Volts, 50 Hz 3 phase and neutral system and shall be completed with 200 amps capacity Copper bus bar with bus bar chamber,internal wiring with suitable size of PVC insulated copper cable copper lugs comprising of following accessories:- ( Main LT panel for pump house JCOs/ORs Qtr near Polo Ground) |
| 48 | Incoming:- (i) MCCB 4 pole 160 A, 35 KA(ii) Multifunctional meter Digital type showing V,A,F,Pf,KW,KWH inbuilt selector switch with CT coiles for three phase -0 1No. (iii) LED Indicator lamp (R,Y,B) Outgoing:-(i) MCCB 4 Pole 20 amps ,415 Volt of breaking capacity not less than 16 KA (Ics=100 % of Icu) with adjustable thermal Setting - 10 Nos (ii) MCB SPN 20 Amp C curve, 10 KA capacity - 02 No(iii) fully automatic Star-delta starter 15 HP or recommended by manufacturer of motor - 10 Nos(iv) Timer 01 No. |
| 49 | Supply, installations, testing and commissioning of factory made LT panel indoor type, dust and vermin proof totally enclosed , fabricated out of steel sections, the door opening shall not be less than 150 degree. The construction of panel board shall be dust, vermin proof, IP 54 standard double shutter gears front and rear frame work and 2.00 mm thick MS sheet duly powder coated made of 40 x 40 x 6 mm thick angle iron frame including necessary PCC work all as specfified suitable for 415 Volts, 50 Hz 3 phase and neutral system and shall be completed with 200 amps capacity Copper bus bar with bus bar chamber,internal wiring with suitable size of PVC insulated copper cable copper lugs comprising of following accessories:-( Main LT panel for pump house offrs Qtr near lakshya shooting range) |
| 50 | Incoming:- (i) MCCB 4 pole 63A, 25 KA(ii) Multifunctional meter Digital type showing V,A,F,Pf,KW,KWH inbuilt selector switch with CT coiles for three phase -0 1No. (iii) LED Indicator lamp (R,Y,B) (i) MCCB 4 Pole 20 amps ,415 Volt of breaking capacity not less than 16 KA (Ics=100 % of Icu) with adjustable thermal Setting - 02 Nos (ii) MCB SPN 20 Amp C curve, 10 KA capacity - 02 No(iii) fully automatic Star-delta starter 15 HP or recommended by manufacturer of motor - 02 Nos(iv) Timer 01 No. |
| 51 | EXTERNAL ELECTRIFICATIONSupply, installation, testing & commissioning of 11 KV Compact Substation with non extensible RMU consisting of following :- |
| 52 | HT SECTIONRMU Non extensible 1 way, 11 Kv, 1 SF6 circuit breaker along with connnected accessories etec. Type :- Free standing, Metal Clad , SF6 insulatedRingmaster with 01 No Direct cable Module & 01 No. 630A Fixed Manual SF6 Circuit breaker - Model DV or Eq.(a) Self Powered Relay IDMT(b) Ring Switches and T OFF SF6 Circuit breaker with integrated Earthing switches(c) Live cable indicator for Ring Switches - Provided(d) Padlocking facility provided(e) Shunt Tripcoil rating - 230 V AC |
| 53 | TRANSFORMER SECTION1250 KVA, 11/0.433 KV, 3 Phase, 50HZ, ONAN Cooled Oil immersed Copper Wound Step Down \\"BIS Marked\\" Transformer Complete with first filling of IS:335 ISI Marked Filtered & Dehydrated Transformer Oil, having 7 position Off-Circuit tap changer with tapping range +/-7.5% in steps of 2.5% each will all standard fittings & accessories including OTI, WTI & Marshalling Box Transformer as per IS-1180:2014 EEL-2 with amendment no. - 1,2,3 & 4Formerly EEL-3 (till 30.03.2022)Losses @ 50% Load - 3220WLosses @ 100% Load - 8400WDetailed Specifications as per Annexure I (A) |
| 54 | LT SECTION LT Panel comprising of LV sideIncoming:- (i) 2000 Amp 4 Pole 415V 50KA MDO Air Circuit Breaker Microprocessor based with O/L, S/C & E/F Protection- 01 No(ii) Multification Meter (iii) RYB Indication LampOutgoing:-(i) 630 Amp 3 Pole 415 V 35KA MCCB with thermal magnetic based release with O/L & S/C Protection- 01 No.(ii) 320 Amp 3 Pole 415 V 25KA MCCB with thermal magnetic based release with O/L & S/C Protection- 01 No.(iii)250 Amp 3 Pole 415 V 25KA MCCB with thermal magnetic based release with O/L & S/C Protection- 01 No.(iv) 830 Amp 3 Pole 415 V 35KA MCCB with thermal magnetic based release with O/L & S/C Protection- 01 No. |
| 55 | ENCLOSURES:-MS Steel Sheet encloser suitable for outdoor installation with ms channels (Base). Provision for receiving Incoming and Outgoing cables through Bottom entry, Excluding Termination Kit and Glands ,Paint shade: Siemens Grey |
| 56 | S&F for compact air insulated rising main Bus trunk with aluminium busbar 315 Amps,breaking capacity of 35 KA and IP 54 protection etc complete all as specified and directed. |
| 57 | S&F for 4 pole plug in box 100 Amp with MCCB 35/50 KA etc complete all as specified and directed. |
| 58 | Supply and installation of Ring main unit outdoor type one incoming two outgoing of 11 KV ,630 Amp etc complete all as specified and directed. |
| 59 | S&F for 9 Mtr Hot deep galvanised octogonal pole with top dia 70mm, bottom dia - 155 mm, thick 3mm, base plate 260mm x 260mm x16mm with single arm bracket etc complete all as specified and directed. |
| 60 | S&F for 9 Mtr Hot deep galvanised octogonal pole with top dia 70mm, bottom dia - 155 mm, thick 3mm, base plate 260mm x 260mm x16mm with double arm bracket etc complete all as specified and directed. |
| 61 | S&F for MCB SP 6 Amp for fixing at hot deep galvanised pole etc complete all as specified and directed. |
| 62 | Supply, Installation, Testing and Commissioning of Auto Power Factor Improvement Capacitor Panel having aggregate of 400 KVAR capacity 8 stage with micro processor based control, factory made indoor type, conforming to IS 8623 & IS 13947, platform mounted suitable for 415 V 3 phase 4 wire, 50 Hz AC supply system , having insulated aluminium bus bar of rating 1000 Amp dust and vermin proof, IP -54 class protection and made of 1.60 mm CRCA MS sheet and 40X40X6 mm thick MS angle iron frame work, powder coated finesh over one coate of red oxide on out side surface and panted in side with two coated of red oxide and both side opening type with apran for cable entery closing locking arrangement including internal wiring with PVC insulated solid copper conductor FRLS cable IS 694 marked , 1100 volts grade of appropriate size (but not less than 2.5 sqmm) and comprising of the following:- |
| 63 | (i) Main Incomming MCCB 630 Amp 35 KA 4 pole - 1 No(ii) Power factor corrector relay 6 Stage Microprocessor based modular type,intelligent APFC relay capable of having self switching ON/OFF to any capacitor suitable to main power factor between 0.95 to 0.99 with digital indication of power factor, preset parameters and having in bult capability of indication and elemination of defective capacitor step.- 01 No(iii) Power capacitor MPP-H type of under mentioned capacity.(a) 100 KVAR - 2 Nos(b) 50 KVAR - 2Nos(c) 25 KVAR - 3 Nos (iv) Power Contactor 250 amp - 1 No(v) Power Contactor 125 amp - 3 No(vi) Power Contactor 50 amp - 2 No(vii) MCCB 250 Amp 10 KA 3 pole - 1 No(viii) MCCB 125 Amp 10 KA 3 pole - 3 No(ix) MCCB 63 Amp 10 KA 3 pole - 2 No(x) Auto/Mannual selector switch(xi) On/Off push button(xii) Aux Contactor 4 No + 4 NC(xiii) including light for capacitor ON/OFF position |
| 64 | Supply, installations, testing and commissioning of factory made LT panel intdoor type, dust and vermin proof totally enclosed, fabricated out of steel sections, the door opening shall not be less than 150 degree. The construction of panel board shall be dust, vermin proof, IP 54 standard double shutter gears front and rear frame work and 2.0 mm thick MS sheet duly painted with powder coated over two coats of redoxide primer and made of 40 x 40 x 6 mm thick angle iron frame all as specfified suitable for 415 Volts, 50 Hz 3 phase and nuetral system and shall be completed with 1200 amps capacity Aluminium bus bar with bus bar chamber,internal wiring with suitable size of PVC insulated copper cable copper lugs comprising of following accessories:- |
| 65 | Incoming:- (i) MCCB 4 pole 400A, 35 KA -01 No(ii) LED Indicator lamp (R,Y,B)- set of three (iii) Multifunctional meter Digital type showing V,A,F,Pf,KW,KWH inbuilt selector switch with CT coiles for three phase -0 1No. |
| 66 | Supply, installations, testing and commissioning of factory made LT panel intdoor type, dust and vermin proof totally enclosed, fabricated out of steel sections, the door opening shall not be less than 150 degree. The construction of panel board shall be dust, vermin proof, IP 54 standard double shutter gears front and rear frame work and 2.0 mm thick MS sheet duly painted with powder coated over two coats of redoxide primer and made of 40 x 40 x 6 mm thick angle iron frame all as specfified suitable for 415 Volts, 50 Hz 3 phase and nuetral system and shall be completed with 1200 amps capacity Aluminium bus bar with bus bar chamber,internal wiring with suitable size of PVC insulated copper cable copper lugs comprising of following accessories:- |
| 67 | Incoming:- (i) MCCB 4 pole 250A, 35 KA -01 No(ii) LED Indicator lamp (R,Y,B)- set of three (iii) Multifunctional meter Digital type showing V,A,F,Pf,KW,KWH inbuilt selector switch with CT coiles for three phase -0 1No. |
| 68 | Supply, installations, testing and commissioning of factory made LT panel indoor type, dust and vermin proof totally enclosed fabricated out of steel sections, the door opening shall not be less than 150 degree. The construction of panel board shall be dust, vermin proof, IP 54 standard double shutter gears front and rear frame work and 2.0 mm thick MS sheet duly painted with powder coated over two coats of redoxide primer and made of 40 x 40 x 6 mm thick angle iron frame all as specfified suitable for 415 Volts, 50 Hz 3 phase and nuetral system and shall be completed with 800 amps capacity Aluminium bus bar with bus bar chamber,internal wiring with suitable size of PVC insulated copper cable copper lugs comprising of following accessories:- |
| 69 | Incoming:- (i) MCCB 4 pole 320A, 50 KA -01 No(ii) LED Indicator lamp (R,Y,B)- set of three (iii) Multifunctional meter Digital type showing V,A,F,Pf,KW,KWH inbuilt selector switch with CT coiles for three phase -0 1No. |
| 70 | Supply, installations, testing and commissioning of factory made LT panel indoor type, dust and vermin proof totally enclosed fabricated out of steel sections, the door opening shall not be less than 150 degree. The construction of panel board shall be dust, vermin proof, IP 54 standard double shutter gears front and rear frame work and 2 mm thick MS sheet duly painted with powder coated over two coated of redoxide primer and made of 40 x 40 x 6 mm thick angle iron frame all as specified suitable for 415 Volts, 50 Hz 3 phase and neutral system and shall be completed with 100 amps capacity Aluminium bus bar with bus bar chamber, internal wiring with suitable size of PVC insulated copper cable copper lugs comprising of following accessories:- |
| 71 | Incoming:- (i) MCCB 4 pole 80A, 25 KA -01 No(ii) LED Indicator lamp (R,Y,B)- set of three (iii) Multifunctional meter Digital type showing V,A,F,Pf,KW,KWH inbuilt selector switch with CT coiles for three phase -0 1No. Outgoing:-(i) MCCB 3 pole 32A, 10 KA -04 Nos(ii)Having space for 3 phase prepaid mater -04 Nos |
| 72 | Supply, installations, testing and commissioning of factory made LT panel indoor type, dust and vermin proof totally enclosed fabricated out of steel sections, the door opening shall not be less than 150 degree. The construction of panel board shall be dust, vermin proof, IP 54 standard double shutter gears front and rear frame work and 2 mm thick MS sheet duly painted with powder coated over two coated of redoxide primer and made of 40 x 40 x 6 mm thick angle iron frame all as specified suitable for 415 Volts, 50 Hz 3 phase and neutral system and shall be completed with 100 amps capacity Aluminium bus bar with bus bar chamber, internal wiring with suitable size of PVC insulated copper cable copper lugs comprising of following accessories:-. |
| 73 | Incoming:- (i) MCCB 4 pole 63A, 25 KA -01 No(ii) LED Indicator lamp (R,Y,B)- set of three (iii) Multifunctional meter Digital type showing V,A,F,Pf,KW,KWH inbuilt selector switch with CT coiles for three phase -0 1No. Outgoing:-(i) MCCB 2 pole 32A, 10 KA C series AC 240 V -04 Nos(ii)Having space for single phase prepaid mater -04 Nos |
| 74 | Supply, installations, testing and commissioning of factory made LT panel outdoor type, dust and vermin proof totally enclosed, fabricated out of steel sections, the door opening shall not be less than 150 degree. The construction of panel board shall be dust, vermin proof, IP 54 standard double shutter gears front and rear frame work and 3.0 mm thick MS sheet duly painted with powder coated over two coats of redoxide primer and made of 40 x 40 x 6 mm thick angle iron frame all as specfified suitable for 415 Volts, 50 Hz 3 phase and nuetral system and shall be completed with 1200 amps capacity Aluminium bus bar with bus bar chamber,internal wiring with suitable size of PVC insulated copper cable copper lugs comprising of following accessories. |
| 75 | Incoming:- (i) MCCB 4 pole 400A, 50 KA -01 No(ii) LED Indicator lamp (R,Y,B)- set of three (iii) Multifunctional meter Digital type showing V,A,F,Pf,KW,KWH inbuilt selector switch with CT coiles for three phase -0 1No. Outgoing:-(i) MCCB 3 pole 400 A, 35 KA -1 No(ii) MCCB TP 160Amp 25 KA DPX 160Legrand, Cat No 4200-45 - 01 No (For Lift)(iii)MCCB TP 25Amp 25 KA DPX 160Legrand, Cat No 4200-01 - 01 No (For PH)(iv) Timer - 1 No & 3 pole Contactor- 1 No for street light control |
| 76 | SEWAGE TREATMENT PLANT OF CAPACITY 135 KLD135 KLD Packaged type STP with following specification:- Quantity :-1 set of 2 Tank, Capacity : 135 m3/day, Average flow : 5416 LPH, Mode of operation : by pump.(a) FRP Treatment tank (MOC: 100% FRP) comprising of the following:-(i) Seperation and sedimentation Chamber(ii) Anaerobic Chamber(ii) Moving bed Chamber(iv) Sedimentation Chamber(v) Disinfection Chamber(vi) In built recirculation Line(vii) MAnholes Cover(viii) Air Blowers (1 Set) (ix) Wire ropes for anchoring the STP Tank(b) Raw water pump (RWP) - 02 Nos (Submersible Sewage pump)(1 W+1 S)(c) Agitating Blower - 03 Nos(d) Interconnecting piping and valves - 01 Set (UPVC Piping, up to 3 mtr from collection tank to STP)(e) Safety acessories for pump, float switch with Cable Quantity :- 01 set(f) Electrical control Panel - 01 Nos |
| 77 | FIRE FIGHTINGS&F for 6 kg capacity Multipurpose dry chemical powder (ABC) type (IS-15683) fire extinguishers consisting of welded MS cylindrical body fabricated from 1.6 mm MS sheet internally protected with anticorrosive treatment and hydraucally tested. Extinguisher externally painted with red enamel and fixed to wall with bracket complete with initial filled/charged . etc complete all as specified and directed. |
| 78 | S&F for CO2 type fire extinguisher of 4.5 Kgs capacity with steel cylinder with a discharge valve and confirming to IS : 15683. Extinguisher shall be painted with red enamel paint and fixed to wall with bracket etc complete all as specified and directed. |
| 79 | S&F for 9 Ltr capacity Foam type (IS-15683) fire extinguishers consisting of welded MS cylindrical body fabricated from 1.6 mm MS sheet internally protected with anticorrosive treatment and hydraucally tested. Extinguisher externally painted with red enamel and fixed to wall with bracket complete with initial filled/charged etc complete all as specified and directed. |
| 80 | S&F for 9 Ltr capacity fire extinguisher water spread pressure type and extinguisher shall be painted with red enamel paint and fixed to wall with bracket etc complete all as specified and directed. |
| 81 | Supply only fire bucket round bottom type enamel painted, white inside and red out side and letter \\"FIRE\\" in black out side and handle with mounting bracket. etc complete all as specified & directed. |
| 82 | Supplying and drawing 2 core, 1.5 sq mm flame retardent low smoke, PVC insulated unsheathed flexible bright annealed copper conductor cable, 1100 volts grade drawn through in the surface / concealed conduit as required Wiring with 2cx1.5sqmm FRLS PVC sheathed copper conductor cable.etc complete all as specified & directed. |
| 83 | S&F for Active repeter Panel etc complete all as specified & directed. |
| 84 | S&F for Electric contol panel for 05 Nos fire pump and 05 Nos jockey pump including all interlink control system for auto run of Electric pumps / diesel engine driven pump comprising of following accessories:-. Incoming:- (i) ACB, 4P, 36KA, 415V,800A, 01 No(ii) LED Indicator lamp (R,Y,B)- set of three (iii) Multifunctional meter Digital type showing V,A,F,Pf,KW,KWH inbuilt selector switch with CT coiles for three phase -0 1No. Outgoing:-(i) MCCB 3 pole 160A, 25 KA -05 Nos(i) MCCB 3 pole 40A, 25 KA -05 Nos(iii)MCB SPN 20 A -02 Nos |
| 85 | S&F for 9W LED EXIT light having Luminous efficency of >100,input voltage range 140-270 V ,input frquency 50-60 Hz includiing rechargable lithiumion cell etc complete all as specified & directed by enginner in charge. |
| 86 | Supply, installation, testing & commissioning of signanges made out of 3 mm thick opaque PVC foam board with computer cut ,PVC non reflective self adhesive vinyl painted foam board ,complete with mirror fateners complete all as specified and directed by th engineer in charge .Sign of size 300 mmx100mm reading 'EXIT' in 12.5 mm block letters in Green and white background ,properly spaced to provide good legibility located directly in corridor near to each staircase and squarely attached to the wall or partition in a way that the topmof the sign is not above 2mm from the finished floor level. etc complete all as specified and directed. |
| 87 | LIFT WORKSupply, installation, testing and commissioning of LT panel board fabricated out of 2mm thick steel with copper bus bar 4 pole equal of capacity in colour code R, Y & B, 240 Amps 415 Volts indoor type wall mounted of size not less than 1350mmx1100mmx400mm, installed on procelain insulators with bus bar chamber. The panel shall be dust and vermin proof, protection class IP 42 class, front opening & compartmental type with approach for cable entry and for easy maintenance duly internally wired with FRLS, PVC insualated stranded copper conductor cable of 1.0 Sqmm including LED indicator for R, Y & B and comprising of the following :-Incoming:- (i) MCCB 160 Amps 4 pole 25 KA 415 Volts, 70-100%, 50 Hz - 01 No.Outgoing:-(i) MCCB 40 Amps Capacity, 25 KA-02 Nos.(i) MCCB 63 Amps Capacity, 25 KA-01 No(iii) Multifunctional meter Digital type showing V,A,F,Pf,KW,KWH inbuilt selector switch with CT coiles for three phase -0 1No. (iv) LED Indicator lamp (R,Y,B)- set of three (v) Copper busbar of 240 amps capacity. |
| 88 | S&F 3 Module plastic surface box with cover plate and back plate etc complete all as specified and directed. |
| 89 | S&F 1 Module plastic surface box with cover plate and back plate etc complete all as specified and directed. |
| 90 | DG SETSSupply, installation, commissioning and testing complete of Manufacturer of OEM (Original Eqpt Manufacturer) manufactured and tested static Diesel Engine driven generating set capable of delivering 400 KVA continuous rating, (10% overload for 1 hour in 12 hours of operation), 415 volts (AC 3 phase, 4 wire system of supply), 50 Hz at power factor 0.8 minimum. The DG set shall consist of a diesel engine coupled directly to a matching alternator, and mounted on Dunlop metallastik foundation pads on a common base frame and thereafter installed in the CPCB approved acoustic enclosure complete with control panel standardised by manufacturer, fuel tank with mounting arrangement and inlet, outlet, return oil arrangement, flexible exhaust pipe complete all as specified and directed and shall include comprise of the following :- |
| 91 | (A) Engine (prime mover) : Diesel engine 1500 RPM, of suitable HP as recommended by manufacturer, water cooled, turbocharged, 12 volts electric battery start, complete with fly wheel and torsional vibration damper, rediator and all standard fittings/fixtures as per standard manufacturing practices and including suitable instrument panel with RPM meter, lub oil temp and pressure gauge, water temp gauge and frequency meter (digital type), battery charging ammeter and fuses, and also including self starter (12V), battery charging alternator, fuel tank etc and complete with HWT and LLOP alarm and shut down safeties complete with first fill of Lub oil and Coolent. (B) Alternator : AC alternator, brushless, 415V AC 50 Hz, 3 phase, 4 wire type, rated for continuous output of 63 KVA, PF 0.8 (lag), 1500 RPM insulation class 'H'; enclosure SPDP (IP 22/23), self excited & self regulated with AVR for + 1% voltage regulation, coupled directly/suitably to and to match the above engine and conforming to BS 5000/IS 4722. (C) Dunlop Metallastik anti-vibration of pads for mounting engine - alternator assembly on the base frame/plate. (D) Base plate : Made out of structural steel as per manufacturer's recommended design/specifications.' |
| 92 | (E) Enclosure : Provision of an integral type, approved/certified acoustic enclosure as per latest CPCB norms, for the DG set to restrict the noise level to 75 DB (A) at one metre and ensure that temperature rise within the canopy shall not exceed 5 - 7 degree celsius, It shall be made of 16 SWG CRCA MS sheet with powder-coated finish on outside and high quality noise absorbent and fire retardant grade acuoustic insulation material duly provided with EPDN gasket lining. There shall be four hinged doors out of which one shall be with a glass window.(i) Silencer : Absorption type, non-resistance, residential.(ii) Internal wiring with PVC copper conductor cables, IS 694 marked, FRLS in conduit and suitable light fittings.(iii) Fuel tank to be provided as per OEM specificaton.(iv) Safeties for high enclosure temperature and emergency shut-down from outside.(v) 1No 12V of suitable AH lead acid batteries and adequate size copper conductor cable leads, housed on & including suitable size MS angle iron frame and necessary clamps, nuts, bolts, washers all as required & as per manufacturer design/specifications.(F) Control panel : Control panel made out of 14 gauge CRCA sheet, powder coated and shall consists of the following: - (i) Ps 0500 Controller (ii) Aluminium Bus bars with suitable capacity incoming & outgoing terminals. (iii) Indicating lamps for load on and 'set running' (iv) Instrument fuses duly wired and ferruled. (v) Circuit breaker(MCCB) of suitable rating with overload and short circuit protections. |
| 93 | Note: To be mounted inside enclosure. (G) Automatic mains failure (AMF) control panel fabricated from CRCA sheet steel of thickness not less than 3.15 mm, suitable for outdoor installation (including CPRI type test certified), dust & vermin proof, protection class I P-54 suitable for 415 volts, 3 phase, 4 wire, 50 Hz, AC supply system with adequate layers of power coating floor mounting type with front opening, the AMF panel shall comprise the following indicating instruments & switches:- AC voltmeter - 01NoVoltmeter selector switch OFF/RY/YB/BR - 01NoFrequency meter - 01NoAC voltmeter of suitable scale - 01NoAmmeter selector switch OFF/R/Y/B - 01NoCurrent transformers of suitable ratio - 01NoBattery charger consisting of - 01No(aa) Transformer / Rectifier unit (bb) DC ammeter /DC voltmeter(cc) Charging rate selector switch OFF/Trickle/BoostMains supply air break contactor, 3 pole of suitable raing - 01NoAlternator air break contactor, 3 pole of suitable rating and provided with a separate overload relay for overload protection - 01NoMains supply voltage monitor - 01NoSet of DC control relays and timers - 01NoSet of push buttons, START, STOP, ACKNOWLEDGE, RESET, MAINS BREAKER, CLOSE/TRIP, ALTERNATOR BREAKER CLOSE / TRIP - 01No |
| 94 | 01 Set of indicating lamps for the following :-LOAD ON MAINS, LOAD ON SET, SET FAILS TO START, LOW OIL PRESSURE, HIGH TEMPERATURE ALARM, HIGH TEMPERATURE TRIP, ALTERNATOR OVERLOAD.Audio - alarm hooter - 01NoKWH meter - One Set of Bus bars - 01NoThe control cubicle will be furnished complete with the necessary control circuit fuses, etc. and will have provisions for making incoming and outgoing connections.KW meter - 01Noset of bus bar - 01NoThe control cubical will be furnished complete with the necessary control circuit fuse etc and will have provision for making incoming and outgoing connectionsOne - set of bus bar - 01NoThe control cubicle will be furnished complete with the necessary control circuit fuses, etc. and will have provisions for making incoming and outgoing connections.Note :(i) In case AMF panel included instead of Standard Control Panel, then Battery charging alternator with inbuilt regulator and battery charging ammeter should be deleted from engine specifications since Battery charger included under AMF Panel specifications.(ii) Platform : PCC foundation /plinth/base shall be provided as per drawing No: TD/2010/109, Sheet No 1/1.(iii) Tool kit, Operation and Maintenance catalogue, 1 year spare part list, overhauling manuals, guarantee card etc shall be provided as per manufacturer standard practices. |
| 95 | Supply, installation, commissioning and testing complete of Manufacturer of OEM (Original Eqpt Manufacturer) manufactured and tested static Diesel Engine driven generating set capable of delivering 75 KVA continuous rating, (10% overload for 1 hour in 12 hours of operation), 415 volts (AC 3 phase, 4 wire system of supply), 50 Hz at power factor 0.8 minimum. The DG set shall consist of a diesel engine coupled directly to a matching alternator, and mounted on Dunlop metallastik foundation pads on a common base frame and thereafter installed in the CPCB approved acoustic enclosure complete with control panel standardised by manufacturer, fuel tank with mounting arrangement and inlet, outlet, return oil arrangement, flexible exhaust pipe complete all as specified and directed and shall include comprise of the following :- |
| 96 | (A) Diesel engine 1500 RPM, of suitable HP as recommended by manufacturer, water cooled, turbocharged, 12 volts electric battery start, complete with fly wheel and torsional vibration damper, rediator and all standard fittings/fixtures as per standard manufacturing practices and including suitable instrument panel with RPM meter, lub oil temp and pressure gauge, water temp gauge and frequency meter (digital type), battery charging ammeter and fuses, and also including self starter (12V), battery charging alternator, fuel tank etc and complete with HWT and LLOP alarm and shut down safeties complete with first fill of Lub oil and Coolent. (B) Alternator : AC alternator, brushless, 415V AC 50 Hz, 3 phase, 4 wire type, rated for continuous output of 63 KVA, PF 0.8 (lag), 1500 RPM insulation class 'H'; enclosure SPDP (IP 22/23), self excited & self regulated with AVR for + 1% voltage regulation, coupled directly/suitably to and to match the above engine and conforming to BS 5000/IS 4722. (C) Dunlop Metallastik anti-vibration of pads for mounting engine - alternator assembly on the base frame/plate. (D) Base plate : Made out of structural steel as per manufacturer's recommended design/specifications. |
| 97 | (E) Enclosure : Provision of an integral type, approved/certified acoustic enclosure as per latest CPCB norms, for the DG set to restrict the noise level to 75 DB (A) at one metre and ensure that temperature rise within the canopy shall not exceed 5 - 7 degree celsius, It shall be made of 16 SWG CRCA MS sheet with powder-coated finish on outside and high quality noise absorbent and fire retardant grade acuoustic insulation material duly provided with EPDN gasket lining. There shall be four hinged doors out of which one shall be with a glass window.(i) Silencer : Absorption type, non-resistance, residential.(ii) Internal wiring with PVC copper conductor cables, IS 694 marked, FRLS in conduit and suitable light fittings.(iii) Fuel tank to be provided as per OEM specificaton.(iv) Safeties for high enclosure temperature and emergency shut-down from outside.(v) 1Nos 12V of suitable AH lead acid batteries and adequate size copper conductor cable leads, housed on & including suitable size MS angle iron frame and necessary clamps, nuts, bolts, washers all as required & as per manufacturer design/specifications.(F) Control panel : Control panel made out of 14 gauge CRCA sheet, powder coated and shall consists of the following: - (i) Ps 0500 Controller (ii) Aluminium Bus bars with suitable capacity incoming & outgoing terminals. (iii) Indicating lamps for load on and 'set running'(iv) Instrument fuses duly wired and ferruled. (v) Circuit breaker(MCCB) of suitable rating with overload and short circuit protections. |
| 98 | Note: To be mounted inside enclosure. (G) Automatic mains failure (AMF) control panel fabricated from CRCA sheet steel of thickness not less than 3.15 mm, suitable for outdoor installation (including CPRI type test certified), dust & vermin proof, protection class I P-54 suitable for 415 volts, 3 phase, 4 wire, 50 Hz, AC supply system with adequate layers of power coating floor mounting type with front opening, the AMF panel shall comprise the following indicating instruments & switches:- AC voltmeter -01 NoVoltmeter selector switch OFF/RY/YB/BR - 01 NoFrequency meter - 01 NoAC voltmeter of suitable scale - 01 NoAmmeter selector switch OFF/R/Y/B - 01 NoCurrent transformers of suitable ratio - 01 NoBattery charger consisting of - 01 No(aa) Transformer / Rectifier unit (bb) DC ammeter /DC voltmeter(cc) Charging rate selector switch OFF/Trickle/BoostMains supply air break contactor, 3 pole of suitable raing - 01 NoAlternator air break contactor, 3 pole of suitable rating and provided with a separate overload relay for overload protection - 01 NoMains supply voltage monitor - 01 NoSet of DC control relays and timers - 01 NoSet of push buttons, START, STOP, ACKNOWLEDGE, RESET, MAINS BREAKER, CLOSE/TRIP, ALTERNATOR BREAKER CLOSE / TRIP - 01 No |
| 99 | 01 Set of indicating lamps for the following :-LOAD ON MAINS, LOAD ON SET, SET FAILS TO START, LOW OIL PRESSURE, HIGH TEMPERATURE ALARM, HIGH TEMPERATURE TRIP, ALTERNATOR OVERLOAD.Audio - alarm hooter - 01NoKWH meter - One Set of Bus bars - 01NoThe control cubicle will be furnished complete with the necessary control circuit fuses, etc. and will have provisions for making incoming and outgoing connections.KW meter - 01Noset of bus bar - 01NoThe control cubical will be furnished complete with the necessary control circuit fuse etc and will have provision for making incoming and outgoing connectionsOne - set of bus bar - 01NoThe control cubicle will be furnished complete with the necessary control circuit fuses, etc. and will have provisions for making incoming and outgoing connections.Note :(i) In case AMF panel included instead of Standard Control Panel, then Battery charging alternator with inbuilt regulator and battery charging ammeter should be deleted from engine specifications since Battery charger included under AMF Panel specifications.(ii) Platform : PCC foundation /plinth/base shall be provided as per drawing No: TD/2010/109, Sheet No 1/1.(iii) Tool kit, Operation and Maintenance catalogue, 1 year spare part list, overhauling manuals, guarantee card etc shall be provided as per manufacturer standard practices. |
| 100 | Supply, installations, testing of electric chimney of size 60cm having suction capacity of 1200 cum per hour with filterless technology sealed motor and insulation for oil deposit and water vapour alongwith self autoclean feature after 30 cycles of operation and minimum 5 year warranty etc etc complete all as specified and directed. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |