| 1 | Dismantling Asbestos cement/ steel (corrugated, semi corrugated, etc.,) sheets as in roof coverings |
| 2 | Dismantling timber scantlings 40 Sqcm and over in section, framed work, in any position. |
| 3 | Dismantling wrought iron or mild steel work of any description not otherwise provided for |
| 4 | M & L for Second class hard wood in scantlings, timber framed and fixed, wrought complete all as specified and directed |
| 5 | All as Sl. Item No. 4 here-in-before but except timber |
| 6 | S & F Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and hevy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc.,conforming to Fe-290 (Gde E-165). |
| 7 | S & F hand rails, half round or other steel section, drilled and countersunk for balusters, wind ties for roof including securing bolts, posts and struts in fencing etc., conforming to Fe-290 (Gde E-165). |
| 8 | S & F Multi rib TM profiled Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick (TCT) of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, cut as per site requirement, fixed with self drilling/self tapping screws with EPDM seal etc., complete all as specified by manufacturer specification and as directed. |
| 9 | S & F Pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick (TCT) of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, cut as per site requirement, fixed with self drilling/self tapping screws with EPDM seal etc., complete all as specified by manufacturer specification and as directed. |
| 10 | Dismantling of Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets |
| 11 | S & F 8mm thick high pressure steam cured (HPSC) pre primed self designer textured non asbestos fibre cement building board laid/ inserted to aluminium frame work in false celings including aluminium anodised snap grid frame work of size 605 x 605mm with hangers 6 mm dia. G.I. (up to 1200mm length) adjusting level fixed to RCC roof slabs/ trusses/ purlins/ rafterserc by means of ceiling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long etc., complete all as specified and as directed. |
| 12 | Demolition of cement concrete (unreinforced) in ground floors and pavings n exc 15cm thickness below or above ground level. |
| 13 | Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for |
| 14 | Demolition of brick work built in cement mortar including all precast concrete articles. |
| 15 | Dismantling of floor, hearth or wall tiling incl cement mortor bedding (but not backing) and removig serviceable tiles to store and rubbish off the premises. |
| 16 | M & L for providing 25mm thick Cement concrete type B-1,1:2:4 (20mm graded aggregate) |
| 17 | M & L Machine cut kota stone slab flooring 20-25mm thick over cement screed including cement screed 15 mm thick in CM 1:6 all as directed base laid and jointed with grey cement slurry mixed with pigment to match theshade of the slab including rubbing and mirror polishing complete |
| 18 | M & L Machine cut kota stone slab in riser of steps, skirting, dado and pillar laid over cement screed 20-25mm thick over cement screed including cement screed 10mm thick in CM 1:4 all as directed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing complete |
| 19 | M & L for rough and smooth grinding polishing to existing marble/ Grainte wall/ gate, piller including filling with white cement with pigment before grinding, polishing and finally with beewax polishing etc including necessarry scaffolding arrangement complete all as directed. |
| 20 | M & L Non skid ceramic tiles 7 to 8mm thick area of each tile exc 0.06sqm but n.exc 0.11sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match as in coloured tiles over and including cement screed 15 mm thick in CM 1:4 all as directed |
| 21 | M & L for glazed ceramic coloured tiles, 350X250x7 or 450 x 350mm x 7mm thick in vertical surfaces such as dado/ skirting etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including cement plaster 10mm thick in CM 1:3 all as specified |
| 22 | M & L for brick work with old size fly ash bricks in cement mortar straight or curved on plan to any radius in half brick thick walls built in CM 1:4 |
| 23 | M & L for providing lintels upto 1.5m clear span on half brick partition wall with cement concrete Type B1, 1:2:4 using 20mm graded stone aggregate including use of form work. |
| 24 | M & L for providing reinfoced cement concrete type B-1 using 20mm graded stone aggregate as in slabs supported on walls, beams and columns in floors, roofs, landings, deck slabs and in shelves complete |
| 25 | Use and waste of formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings, shelvings and similar work n.exc 200mm thick for fair finished flat surfaces complete all as directed. |
| 26 | M & L for 20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over 15 mm thick screed in CM 1:4 |
| 27 | S & F TMT steel bars 10mm dia and over, cut to length bent to shape required as in reinforce ment to lintels complete all as directed. |
| 28 | All as per item No.27 here-in-before but 6mm to 8mm dia |
| 29 | All as per item No.27 here-in-before but 5mm dia and over upto and including 10mm dia in stirrups. |
| 30 | Taking down chowkats or frames with shutters (without taking off shutters from frames) exc 1.5 Sqm but n.exc 4 Sqm each including making good disturbed surfaces |
| 31 | All as per Sl. Item No.30 her-in-before but n.exc 1.5 Sqm each. |
| 32 | M & L for IInd class hard wood Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, supplied and fixed |
| 33 | S & F 35mm thick II nd class HW factory made plain framed panelled door shutter two panels, with lock rail and panel of 9mm BWP, commercial ply or 12mm veneered particle board with commercial face veneering on both faces |
| 34 | M & L for 35mm thick II nd class hardwood glazed and skeleton shutters, open rebated and prepared to receive glass, gauge etc., without sash bars, edges of framing plain, chamfered or rounded fitted with cut and mitred beads for securing glass or gauge etc., size of members of shutters as specified in SSR part I, section 8, clause 8.24 (a) supplied and fitted to chowkats. |
| 35 | M & L for 30mm thick II nd class hardwood glazed and skeleton shutters, divided into squares with plain chamfered or rounded mitred and rebated sash bars any numbers as in windows,prepared to receive glass, gauge etc., without sash bars, edgesof framing plain, chamfered or rounded fitted with cut and mitred beads for securing glass or gauge etc., size of members of shutters as spcd in SSR part I, section 8, clause 8.24 (a) supplied and fitted to chowkats. |
| 36 | Cutting holes in brick walls exc half brick n.exc one brick, built in cement mortar for inserting hold fast and making good dismantled portion in cement concrete 1:2:4 type B-1 as required |
| 37 | S & F mild steel FI 25 x 3mm holdfast 300mm long, hand made sliding bolts, clamps, hook and pintle hinges, large hasp and staples similar articles conforming to Fe 290 gde E 165 |
| 38 | Hacking out old broken glass (any thickness size, quality or description) from wooden frames glazed with putty or fixed with beads. |
| 39 | S & F 4mm thick Sheet glass, ordinary quality and glazing with oil putty in square n.exc 0.5 sqm in each pane and fixed to aluminum frames using rubber packing complete. |
| 40 | S & F 4mm thick frosted Sheet glass, ordinary quality and glazing with oil putty in square n.exc 0.5 sqm in each pane and fixed to aluminum frames using rubber packing |
| 41 | S & F stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples all as specified. |
| 42 | S & F Butt hinges 100mm, stainless steel hinges fixed with stainless steel screw with frame |
| 43 | S & F Butt hinges 75mm, stainless steel hinges fixed with stainless steel screw with frame |
| 44 | S & F Alumininum anodised barrel tower bolts of extruded section 200mm size |
| 45 | S & F Alumininum anodised barrel tower bolts of extruded section 150mm size |
| 46 | S & F Extruded aluminium alloy handles, fabricated type, anodised 150mm long |
| 47 | S & F Extruded aluminium alloy handles, fabricated type, anodised 125mm long |
| 48 | S & F 300 mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolt and sliding bolts of extruded sections or cast aluminium alloy and fixed. |
| 49 | M & L for old size Brick work with fly ash bricks straight or curved on plan and 6 metre mean radius built in CM 1:6 all as specified |
| 50 | Cutting openings, through brick walls built in cement mortar for door, window and other openings or enlarging existing openings, converting window into door openings etc., or cutting out defective brick work for under pinning, including providing, fixing and removing shoring cleaning and stacking bricks, removing demolished materials not exc 50m complete all as specified and as directed. |
| 51 | Forming jambs etc., to openings (to foregoing item), in Cement mortar 1:6, including cutting, toothing and properly bonding into old work, also facing, jointing and pointing to match existing work compete |
| 52 | Making good under cills or over arches, lintels and bressumers, including all pinning when necessary in Cement ortar 1:6 |
| 53 | Removing the existing roof treatment of any description completely and removel of all the debris from site and rubbish off the premises complete all as directed. |
| 54 | M&L for preparation of even and smooth surface with screed bed 20mm thick in CM 1:4 with using waterproofing liquid as per manufacturers instructions.(WPC Measured and paid separately) |
| 55 | M & L for water proofing treatment with APP modified prefabricated five layer water proofing membrane, not less than 3mm thick and weighing not less than 3.00 Kg/Sqm reinforced with non woven polyester matt black finished over compatiable primer at 0.3 litre/Sqm, touching the membrane on whole surface uniformly while unrolling the membrane by LPG and sealed with trowel after necessary preparation of surface complete all as per manufactures instructions . The over lap joint shall be provided of 75mm in longitudinal direction and 100mm in tranverse direction respectively. All the angles, abutments and the drainage outlets shall be sealed with extra care to ensure full bondage.Manufactures:- IWL India Ltd/SAPL (ARGO-P) Hydrotech Ltd (Hydroflame)/STP.Note:- The work shall be carried out be authorised applicators of manufactures |
| 56 | Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water etc |
| 57 | M&L for Rendering 10mm thick in CM 1:6 on fair faces of brick work or concrete surfaces and finished even and smooth without using extra cement on internal wall surfaces. |
| 58 | M & L for rendering 10mm thick in CM 1: 6 as under layer and 5mm thick in CM 1:4 mixed with water proofing compound as finishing layer to external wall surfaces and finishing the surface even and smooth including taking down existing cement plaster if necessary. |
| 59 | M & L for preparing new wooden surfaces of any description, over 10cm in width or girth, not otherwise described and applying two coat of Synthetic enamel paint over a coat of pink primer , complete all as specified and directed. |
| 60 | M & L for preparing new steel surfaces of any description, over 10cm in width or girth, not otherwise described and applying two coat of Synthetic enamel paint over a coat of red oxide primer , complete all as specified and directed. |
| 61 | Supply only integral liquid water proofing compound. |
| 62 | S & F in repairs Bib taps 15mm bore cast copper alloy with crutch or butter fly handle chromium plated screwed down for iron pipe or for brass ferrule fixed. |
| 63 | S & F in repair stop valves15mm bore chromium plated with long shank and cup (Concealed type) high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions and fixed |
| 64 | S & F in repairs PVC connection 15mm size with PTMT nuts of length 600mm. |
| 65 | S & F in repairs 450 x 600mm bevelled edge mirror of selected quality glass, mounted on 6 mm thick AC building board or commercial plywood and fixed to wooden plugs with CP brass screws and cup washers |
| 66 | S & F in repairs Brass chromium plated Tubular towel rail, 20mm dia, D type, 30cm long between flanges |
| 67 | Demolition and breaking up drain pipes of 110mm/75mm dia any type set in cement mortar |
| 68 | S & F PVC (SWR) pipes single socketed, in any length with rubber ring joints or solvent cement, laid in floor , 75mm bore. |
| 69 | S & F PVC (SWR) pipes single socketed, in any length with rubber ring joints or solvent cement, fixed to walls, 75mm bore. |
| 70 | S & F PVC (SWR) pipes single socketed, in any length with rubber ring joints or solvent cement, laid in floor, 110 mm bore. |
| 71 | S & F PVC (SWR) pipes single socketed, in any length with rubber ring joints or solvent cement, fixed to walls, 110 mm bore. |
| 72 | S & F PVC (SWR) bend 110 mm bore. |
| 73 | S & F PVC (SWR) floor trap with grating including jointing to solvent cement wast pipe 75 mm dia. |
| 74 | S & F PVC (SWR) Gully trap 125 / 110mm setting and jointing with solvent cement. |
| 75 | S & F PVC (SWR) vent cowl 110 mm |
| 76 | S & F PVC (SWR) junction single, (Single T) equal or unequa for 110 mm bore pipe with access door |
| 77 | S & F PVC (SWR) junction single, (Single T) equal or unequa for 75 mm bore pipe with access door |
| 78 | S & F PVC (SWR) bend 75 mm bore. |
| 79 | S & F Stack clamps out of 50mm by 5mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof Bore of pipe 110mm |
| 80 | S & F in repairs rotationals moulded polythylene water storage tanks of capacty 1000 litres (cylindrical, vertical with closed top) hoisted and fixed in position all as specified including taking down old tanks |
| 81 | S & F Ball valves 25mm high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. (Minimum weight 15mm-142gms/ 20mm - 210gms/ 25mm-455gms/ 40mm - 690gms) |
| 82 | S & F in repairs 25mm Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe. |
| 83 | S & F in repairs 50mm Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe. |
| 84 | Taking up or taking down steel/iron tube of 20 mm bore and connections including cleaning for refixing or removal to store complete all as specified. |
| 85 | Supplying and laying of 20 mm CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings laid in walls/floors complete all as specified. |
| 86 | Taking up or taking down steel/iron tube of 25 mm bore and connections including cleaning for refixing or removal to store complete all as specified. |
| 87 | Supplying and laying of 25 mm CPVC pipes SDR 11 & Plain CPVC SDR 11 fittingslaid in walls/floors complete all as specified. |
| 88 | Taking up or taking down steel/iron tube of 50 mm bore and connections including cleaning for refixing or removal to store complete all as specified. |
| 89 | Supplying and laying of 50 mm CPVC pipes SDR 11 & Plain CPVC SDR 11 fittingslaid in walls/floors complete all as specified. |
| 90 | Complete removal of existing treatment on walls and applying two coats of oil bound distemper over a coat of primer over a coat of wall care putty of 3mm thick to internal wall surfaces complete all as spcd and as directed. |
| 91 | Preparing new plastered wall surfaces and applying two coat of oil bound distemper over a coat of primer over wall care putty of 3mm thick all as spcd and as directed. |
| 92 | Preparation of old decorated ceiling surfaces including necessary scaffolding and applying one coats of white wash including filling the cracks/depressions using chalk whitening wherever required all as specified |
| 93 | Complete removal of existing treatment on walls and applying two coats of exterior weather proof paint over a coat of weather proof primer to all external wall surfaces complete all as spcd and as directed. |
| 94 | M & L for preparing old wooden surfaces of any description, over 10 cm in width or girth, not otherwise described and applying one coat of Synthetic enamel paint all as specified and directed. |
| 95 | M & L for preparing old steel surfaces of any description, over 10 cm in width or girth, not otherwise described and applying one coat of Synthetic enamel paint all as specified and directed. |
| 96 | M & L for 75mm thick plain cement concrete type C1, 1:3:6 as in plinth protection and finishing the surface even and smooth without using extra cement |
| 97 | Taking down carefully copper point wiring (light, fan, socket or power) complete (fitting such as switches, ceiling roses, pendants, regulators, sockets, etc can be measured separately) removing the material from wall/ceiling etc, making good the disturbed surfaces and taken as credit all as directed. |
| 98 | M & L for Point wiring complete with 1.5sqmm FRLSH single core PVC insulated unsheathed cable 1100 volts grade, multistranded copper conductor drawn through and including non-metallic rigid PVC conduit PVC conduit fittings and conduit asccessorries concealed in walls, roofs and floors etc., including Modular flush boxes and Modular cover plates for switches concealed in walls, roof and socket/ electronics fan regulator/ telphone socket, including provision of 1.5sqmm PVC insulated unsheathed cable with multi stranded copper conductor as earth continuity conductor and connecting to common earth dolly all as specified for one light/ fan point controlled by one way switch complete including cutting chases, pinning in, making good to facing where required and pointing in cement mortar 1:3 for concealed conduit wiring and making good the disturbed surfaces, matching with the existing wall surfaces, cutting not exceeding 10Cm girth all as specified and as directed. |
| 99 | All as per Sl.Item No.98 here-in-before but for One Ceiling fan point controlled by one switch and one regulator. |
| 100 | All as per Sl.Item No.98 here-in-before but for One 3 pin 5 amps switch socket on independent board. |
| 101 | All as per Sl.Item No.98 here-in-before but for One 3 pin 5 amps switch socket on same board along with other switches. |
| 102 | All as per Sl.Item No.98 here-in-before but for One exhaust point controlled by one switch |
| 103 | All as per item No.98 here-in-before but with 4 sqmm FRLSH copper conductor cable with 4 sqmm PVC copper conductor FRLSH cable as earth continuity conductor for one socket outlet 15/16 amps controlled by one switch 15/16 Amps on independent board all as specified and as directed. |
| 104 | S & F MCCB Distribution board, TP&N , vertical , double door, sheet steel, enclosure powder coated with 160 Amps rated busbar with neutral link,415 Volts 8 way fixed on wall duly grouted in solid block wall or on wooden board with electrical connection completeincluding taking down Old DBs all as specified and directed. |
| 105 | S & F MCCB 3 Pole , 415 V, Adjustable type, 200 Amps with breaking capacity 36 KA adjustable thermal & fixed magnetic setting complete all as specified and directed. |
| 106 | S & F TP 32 Amps 415V 10KA 'C' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the DB complete with connection testing and commissioningincluding taking down Old MCB complete all as directed. |
| 107 | S & F MCB Distribution board , VTPN, 415 volts Tripple pole and neutral ,double door, sheet steel, enclosure powder coated with 200 Amps rated busbar with neutral link, 4 ways , fixed on wall duly grouted in solid block wall or on wooden board with electrical connection complete all as specified and directed. |
| 108 | S & F TPN/FP 415 volts, 40 amps 'C' Curve 10 kA Capacity all as directed. |
| 109 | S & F MCB Distribution board , 240 volts single pole and neutral ,double door, sheet steel, enclosure powder coated with 100 Amps rated busbar with neutral link, 8 ways , fixed on wall duly grouted in solid block wall or on wooden board with electrical connection complete all as specified and directed. |
| 110 | S & F rating 240V, 10KA 'C' curve miniature circuit breaker MCB SPN 32A current carrying capacity in the MCB DB complete with connection testing and commissioning including taking down Old MCB complete all as directed. |
| 111 | S & F rating 240V, 10KA 'C' curve miniature circuit breaker MCB SP 5- 32A current carrying capacity in the MCB DB complete with connection testing and commissioning including taking down Old MCB complete all as directed. |
| 112 | S & F Triple pole and earth enclosure with a three pin and earth plug with socket, 415V, 32 Amps complete with one triple pole MCB all as directed. |
| 113 | M & L for sub main wiring with PVC insulated, 1100 volts grade single core FRLSH multistranded copper conductor cable conforming to IS specifications, 2 runs of 16sqmm including one run of 16 sqmm single core multistranded copper conductor PVC insulated cables as earth continuity conductor with colour code drawn through and including one run of 25mm dia rigid PVC conduit and conduit accessories or casing capping incl accessories fixed on wall/ceiling etc., or concealed in wall and connecting to common earth dolly including taking down old unsv all as specified and directed. |
| 114 | M&L for sub main wiring with PVC insulated, 1100 volts grade single core multistranded copper conductor cable conforming to IS specifications, 4 runs of 16sqmm FRLSH including two run of 16sqmm single core multistranded copper conductor PVC insulated cables as earth continuity conductor with colour code drawn through and including one run of 25mm dia rigid PVC conduit and conduit accessories or casing capping incl accessories fixed on wall/ ceiling etc., or concealed in wall and connecting to common earth dolly including taking down old unsv all as specified and directed. |
| 115 | S & F Ceiling rose surface bakelite 65mm x 50 mm two to three terminals all as directed. |
| 116 | S & F Modular switch 1 way 6A, 1 module, 240 Volts complete all as specified and directed |
| 117 | S & F Modular switch 1 way 16A, 1 module, 240 Volts complete all as specified and directed |
| 118 | S & F Modular Socket, 6A - 2/3 pin combined 2 module complete all as specified and directed |
| 119 | S & F Modular socket 6A/ 16A - 2/3 pin combined 2 module complete all as specified and directed |
| 120 | S & F Modular Fan step regulator, 100W - 2 module for ceiling Fan of 1200 mm sweep all as specified and as directed. |
| 121 | S & F in repairs Modular white cover with plate with frame 3 module incl matching with white cement work if necessary complete all as specified and as directed |
| 122 | S & F in repairs Modular white cover with plate with frame 6 module incl matching with white cement work if necessary complete all as specified and as directed |
| 123 | S & F in repairs Modular white cover with plate with frame 12 module incl matching with white cement work if necessary complete all as specified and as directed |
| 124 | S & F in repairs Modular white cover with plate with frame 18 module incl matching with white cement work if necessary complete all as specified and as directed |
| 125 | S & F in repairs Modular flush box 3 module |
| 126 | S & F in repairs Modular flush box 6 module |
| 127 | S & F in repairs Modular flush box 12 module |
| 128 | S & F in repairs Modular flush box 18 module |
| 129 | S & F LED luminaire 600mm x 600mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete. |
| 130 | S & F LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceilingrose complete. |
| 131 | Taking down Ceiling/ Exhaust fan, sealing cable end, dismantling blades and removing fan and blades to and depositing it to MES store yard without any damage It included the charges of transporation of fan and labour cost etc. |
| 132 | S & F ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and as directed. |
| 133 | S & F exhaust fan, steel body AC single Phase. 230V of size 450mm sweep heavy duty, blades, and frame and louvers complete all as specified and as directed. |
| 134 | M & L for Earthing complete with galvanised steel earth plate electrode of size 60cm x 60cm x 6mm thick burried directly in ground vertically to a depth of not less than 2.25 mtr below normal ground level with top edge of earth plate not less than 1.5 mtr below normal ground level, connected to galvanised iron/steel earth wire 4mm dia by means of bolts, nuts, washers and check nuts made out of galvanised iron, protected by GI pipe light grade 15mm bore dia and connected to main control board all as shown in Electrical plate No.3 of MES SSR Part I including necessary excavation and earth work in any type of soil, salt, charcoad dust, PCC 1:2:4 type B1 in chamber, RCC 1:2:4 chamber cover with 6 mm dia MS bar at 100mm centre to centre both ways and MS 6mm dia hook complete all as specified and directed. Please Enable Macros to View BoQ information |