| 1 | Demolition of cement concrete unreinforced in ground floors and pavings n'exc 15cm thick below or above GL complete all as specified and directed |
| 2 | Dismantling floor, hearth or wall tiling of any description and in any position including cement mortar bedding (but not backing) complete all as specified and directed. |
| 3 | Demolition of brick work or stone/ boulder masonry work built in cement mortar including all quoins, arches, pillars etc but excluding ashlar facings, dressed stone work and precast concrete articles complete all as specified and as directed. |
| 4 | Dismantling Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover filletscomplete all as specified and directed. |
| 5 | Taking down chowkhat or frame (without taking off shutter from the frame), area of opening n'exc 1.5 Sqm each, removing from the site complete all as specified and directed.Note:- In order to facilitate the taking down of chowkhat or frame with holdfasts, the cost of cutting holes or dismantling of brick/stone/concrete masonry work of any description in Jambs of existing opening or removing any other fixing arrangement and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4, type B-1 as required so as to re-fix the holdfasts of new chowkhat or frame shall deemed included in quoted unit rates.(ii) Hold fast / fasteners shall be measured and paid separately in respective item hereunder. |
| 6 | Taking down chowkhat or frame (without taking off shutter from the frame), area of opening exc 1.5 sqm and n'exc 4.00 sqm each, removing from the site complete all as specified and directed.Note:- In order to facilitate the taking down of chowkhat or frame with holdfasts, the cost of cutting holes or dismantling of brick/stone/concrete masonry work of any description in Jambs of existing opening or removing any other fixing arrangement and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4, type B-1 as required so as to re-fix the holdfasts of new chowkhat or frame shall deemed included in quoted unit rates.(ii) Hold fast / fasteners shall be measured and paid separately in respective item hereunder |
| 7 | Dismantling Dismantling timber scantlings 40 sq. cm and over in section, Framed work, in any position complete all as specified and directed. |
| 8 | Dismantling Dismantling timber scantlings 40 sq. cm and over in section, Un-Framed work, in any position complete all as specified and directed. |
| 9 | M&L for 75mm thick cement concrete 1:3:6 type C-2 (using 40mm graded stone aggregate) as in plinth protection, finishing surfaces even & smooth without using extra cement including filling of construction joint with bituminous sealing compound complete all as specified and directed. |
| 10 | M&L for PCC 1:4:8, type D2(using 40mm graded stone aggregate) as in foundations/ mass concrete etc complete all as specified and directed. |
| 11 | M&L for Brickwork with old size sub class 'B' bricks, straight or curved on plan exc 6m mean radius, built in Cement mortar 1:4 complete all as specified and directed. |
| 12 | Taking down cement plaster on brick work or stone walls, etc incl raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and directed. |
| 13 | M&L for 15 mm thick rendering in cement mortar (1:6) on brick / concrete/ stone walls, surfaces finished even and fair without using extra cement, complete all as specified and directed. |
| 14 | M&L for 10mm thick rendering in cement mortar 1:4 mixed mixed with liquid water proofing compound @ 200ml per 50 kg bag of cement on brick / concrete/ stone walls, surfaces finished even and fair without using extra cement, complete all as specified and directed.Note : Water roofing compound shall be measured and paid separately in respective item of this BOQ |
| 15 | Supply only liquid water proofing compound for mixing in cement mortar or PCC complete all as specified.Note : (i) The WPC compound specified in any item of this BOQ or ordered by Engineer-in-charge (if not mentioned in BOQ item but technically required shall only be measured and paid under this item.(ii) Contractor shall provide purchase vouchers for full quantities incorporated in the work and Engineer-in-charge shall keep defaced purchase vouchers in record and entered the same in MB |
| 16 | M&L for two coats of cement base wall care putty in two coats @ 1Kg/Sqm (0.5Kg in each coat) on new plastered surface of wall/ceiling as preparatory work to painting including cleaning surface before application of putty and necessary rubbing of puttied surface with appropriate size of sand paper so as to make the surface truly smooth, free from all dirt/ dust and made ready to receive the finishing coat of paint complete all as specified and directed.Make : Birla white / JK putty/ Burger |
| 17 | M&L for complete removal of existing treatment and applying two coats of cement base wall care putty (approx thickness 1mm) on newly plastered surface of wall/ceiling as preparatory work to painting including brooming down with steel wire brushes scraping down moulds moss and efflorescent salts and treating oil and greasy spots, removing of nails, making good holes , cracks etc cleaning surface before application of putty and necessary rubbing of puttied surface with appropriate size of sand paper so as to make the surface truly smooth, free from all dirt/ dust and ready to receive the finishing coat of paint complete all as specified and directed.Make : Birla white / JK putty/ Burger |
| 18 | M&L for two coat of acrylic interior emulsion paint over and including one coat of interior primer on prepared surfaces of wall complete all as specified and directedMake : Asian(Apcolite)/ Burger(self breath easy)/ Nerolac(nerolac Impression HD)Note : (i) The emulsion used shall be of approved colour by GE diluted as per manufacturer's instructions(ii) Contractor shall ensure washing floors, cleaning glass , joinery , electric fitting, etc after painting work with entire satisfaction of Engg-in-charge. |
| 19 | M&L for two coats of acrylic exterior emulsion paint over and including one coat of exterior primer on prepared surfaces of wall complete all as specified and directed.Make : Asian(Appex Altima)/ Burger(weather coat all Guard)/ Nerolac(Excel total)Note : (i) The emulsion used shall be of approved colour by GE diluted as per manufacturer's instructions(ii) Contractor shall ensure washing floors, cleaning glass , joinery , electric fitting, etc after painting work with entire satisfaction of Engg-in-charge. |
| 20 | M&L for non skid, joint free, coloured ceramic tiles, 7mm to 8 mm thick (Square or rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc set over and including 15 mm thick cement screed in (1:6) CM set and jointed in neat cement slurry and pointed in white or coloured cement to match with the colour of tiles complete all as specified and directed. |
| 21 | All as per item 20 above but as in skirting fixed over and including 10mm thick rendering in CM (1:4). |
| 22 | M&L for machine cut Kota stone slab 18mm to 20 mm thick, as in flooring (size not less than 550x550mm), laid over and including 20mm thick cement screed, jointed with grey cement slurry mixed with pigment to match the shade of the slab including grinding, rubbing and mirror polishing complete all as specified and directed. |
| 23 | M&L machine cut kota stone slab 18-20mm thick as in skirting, steps riser etc (size not less than 1200x600mm) laid over 10mm thick plaster in CM (1:4), laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including grinding, rubbing & polishing complete all as specified and directed. |
| 24 | M&L for suspended false ceilling comprising of non asbestos fibre cement bulding boards of size 595mmx595mm,6mm thick fixed or laid/inserted to powder coated GI frame work with screws over GI perimeter channel 0.55mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to sourrounding wall using nylon sleeves and screws at 450mm centre to centre/ intermediate channel 0.9 mm thick having two equal flanges of 15mm each and web of 45mm suspended from soffit at approx 900mm centre to centre with GI cleat and steel expansion fastners with and including ceiling section (not exc 1.2m length) of 0.55mm thickness having kurled web of 50mm and flange of 26mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm center to centre including hangers 6mmm dia GI (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40x3mm size 60mm long complete all as specified and directed. |
| 25 | S&F 125 mm X 60 mm size pressed steel frames for door with one or more rebates including necessary lugs, hinges, lock strike plate etc , one shop coat of red oxide primer, filing PCC (1:3:6), type C-0 (using 12.5 mm graded store aggregate) in hollow portion of frame and two coat of synthetic enamel paint after preparation of primed surface complete all as specified and directed.Note: The cost of lugs, hinges, lock strike plate etc, shop coat, synthetic enamel paint and PCC filling work shall be deemed included in quoted unit rates. |
| 26 | S&F 30 mm thick factory madeflush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides with 2mm thick Plain colour PVC sheet fixed or laid on one side of board and 2mm thick wood grained prelam PVC sheet on other side of board , using rubber based adhesive, including heat bent of PVC sheet as lipping on the edges of doors, supplying & fixing at site as per specification complete all as specified and directed.Note : total thickness of door shall be 35mm approx) Make: Greenply/ century / Action tesa |
| 27 | M&L for 2nd class HW (Teak) glazed and skeleton shutters ( factory made), 35 mm thick open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part-I, Section 8, cla-use 8.24 (a); for doors supplied and fitted to chowkhats including two coats of synthetic enamel paint over a coat of pink primer (after preparation of surfaces complete all as specified and directed.Note: (i) The cost of synthetic enamel paint and primer work shall deemed included in quoted unit rates.(ii) The glass and wire gauge shall be measured and paid separately under respective item here under. |
| 28 | S&F galvanised mild steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.45mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and directed. |
| 29 | M&L for two coats of synthetic enamelled paint over a coat of red oxide including preparation of new steel surfaces of any description over 10 cm width or girth complete all as specified and directed. |
| 30 | S&F aluminium windows sliding type three track powder coated consisting of frame bottom with gutter of size min 92.34 X 32mm side and top of size min 92.34X29.70, shutters vertical 39X20 mm, shutter top & bottom of size min 20X39 mm , shutter interlock min size 39X20 mm with rollers and concealed locking arrangements with 4 mm thick tinted glass with rubber gasket ,brush and aluminium beading ,aluminium wire mess 0.36 mm dia and width of aperture 1.45 mm etc including necessary cutting holes on wall and floor and confirming to IS complete all as specified and directed. Note : Aluminium section(s) thickness shall not be not less than 1.50 mm. |
| 31 | S&F in repair 25mm dia stainless steel (202 Grade) curtain rod not less than 0.70mm thick with end caps (Latoo) and brackets complete all as specified and directed.Note : In openings exceeding 1.2m wide, additional brackets shall be provided so as the distance between two consecutive brackets shall not exceed 1.2m. |
| 32 | S&F 150mm long aluminium anodised barrel tower bolt , extruded section complete all as specified and directed. |
| 33 | S&F 150mm size extruded aluminium alloy handle, fabricated type, anodised complete all as specified and directed. |
| 34 | S&F 300 mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and directed. |
| 35 | M&L for mild steel structural work as in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats, etc. complete all as specified and directed. |
| 36 | S&F rolled section as in main and cross beams, hip and jack rafters, purlins where connected to common rafters and running rails and guides for sliding doors fixed with angle cleats or other connecting plates confirming to Fe-290 ( Gde E-165) complete all as specified and directed |
| 37 | S&F Mild steel screw bolts (machine made) with hexagonal or square head at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, length of bolt exc 22.5cm but n' exc 30cm long and dia of shank 11 to 15mm complete all as specified and directed. |
| 38 | S&F MS plates (plain or chequered) channels square cut to or notched forming holes with riveted bolted or welded attachment for Fe-410W complete all as specified and directed. |
| 39 | M&L for two coats of synthetic enamelled paint over a coat of red oxide including preparation of new steel surfaces of any description over 10 cm width or girth complete all as specified and directed. Please Enable Macros to View BoQ information |
| 40 | M&L for two coats of synthetic enamelled paint over a coat of red oxide including preparation of new steel surfaces of any description over 10 cm width or girth complete all as specified and directed. Please Enable Macros to View BoQ information |