| 1 | Demolition of cement concrete (un reinforced) in ground floor and paving n. exc 15 cm thickness (below or above ground level) complete all as specified and as directed. |
| 2 | M&L for brick work with old size fly ash bricks, straight or curved on plan exc. 6 m mean radius, built in CM (1:6) including demolition of brick work in cement mortar including all quoins, arches, pillars etc complete all as specified and directed. |
| 3 | M&L for 15mm thick rendering on internal surface in cement mortar 1:6 to on brick masonary wall surfaces or on other than fair faces of brick masonary finished even and fair without using extra cement complete all as specified and directed. |
| 4 | M&L for 15mm thick rendering on internal surface in cement mortar 1:6 to on brick masonary wall surfaces or on other than fair faces of brick masonary finished even and fair without using extra cement including taking down old cement plaster complete all as specified and directed. |
| 5 | M & L for 15 mm thick rendering on external surface on fair faces of brick work or concrete surfaces with cement mortar 1:4 with mixing of water proofing compound as per manufacturer’s instructions complete all as specified and directed. Note:- Water Proofing compound shall be measured and paid seprately. |
| 6 | M&L for 15mm thick rendering on internal surface in cement mortar 1:6 to on brick masonary wall surfaces or on fair faces of brick masonary finished even and fair without using extra cement complete all as specified and directed. |
| 7 | Supply only liquid water proofing compounding complete all as specified and directed. |
| 8 | M & L for applying two coat of oil bound distemper white or tinted on newly decorated or undecorated wall surface including preparation of surfaces and applying 2 mm thick putty by washing rubbing down and stoping of distempered and painted surfaces complete all as specified and directed. |
| 9 | M & L for applying two coat of oil bound distemper white or tinted on old decorated wall surface including preparation and applying 2 mm thick puttyof surfaces by washing rubbing down and stoping of distempered and painted surfaces complete all as specified and directed. |
| 10 | M&L for preparation of new plastered walls surfaces and applying two coats of Cement based paint paint over a coat of 2mm thick wall care putty complete all as specified and directed. |
| 11 | M&L two coat of cement base paint on old plastered wall surfaces over a coat of 2mm thick wall care putty of any description including preparation of surfaces, complete all as specified |
| 12 | M&L for 25 mm thick cement concrete type B0, 1:2:4 (using 12.5 mm graded stone aggregate) in floors, finished rough to receive floor tiles complete all as specified and directed |
| 13 | M&L non skid ceramic coloured tiles 7 to 8 mm thick (Square/ rectangular ) area of each tile in floors etc.area of each tiles exc 0.18 sqm but not exceeding 0.38 sqm set and jointed in neat cement slurry and pointed in white or colour cement to match, over and including M&L for 15 mm thick screed plaster in CM 1:6 and dismantling of existing floor, or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premisescomplete all as specfied and directed. |
| 14 | All as per serial item as above but as in vertical surfaces including rendering M&L for 10 mm thick in cement mortar 1:4, as in backing layer |
| 15 | M&L for 75 mm thick cement concrete 1:3:6, type C2, with using 40 mm graded stone aggregate in floor/plinth protection, finish the surface even and smooth without using extra cement including forming necessary joints 12 mm wide to the full depth of PCC at every 3 mtr and every change of direction and filling the same with bitumen filler 1:3 by weight complete all as specified and directed. |
| 16 | Taking down Chowkats or frames with shutters (without taking off shutters from the frame) exc 1.50 sqm but n.exc 4.0 sqm each and removing from site including making good disturbed portions of wall with new or old bricks, lintel, cills etc in CM 1:4 complete all as specified and directed. |
| 17 | Taking down Chowkats or frames with shutters (without taking off shutters from the frame) n.exc 1.50 sqm each and removing from site including making good disturbed portions of wall with new or old bricks, lintel, cills etc in CM 1:4 complete all as specified and directed. |
| 18 | Taking down Shutters of any description n exc 1 sq. m each |
| 19 | Taking down Shutters of any descriptionbut exc 1 sq. M and n exc 2 sq. M each |
| 20 | S&F 125mmx60mmx1.00 mm thick pressed steel, frames for door with one or more rebates including filling and compaction with PCC (1:3:6) Type C-1 using 20 mm graded stone aggregate, necessary fixing lugs, hinges, lock strike plate, etc, including wooden texture finished paint on the frame surface complete all as specified and directed. |
| 21 | S&F 3.0 mm thick sheet glass ordinary quality and glazing with oil putty or in squares not exceeding 0.50 square metre in each pane, all as specified. |
| 22 | S&F mild steel framed work such as grills grating etc with ends of bars shouldered and/or riveted or forged into spikes framed guard bars, barrel iron doors ladders framed balusters walk ways railing frame work of water tanks and similar work confirming to Fe -290 Gde-E-165 all as spd and directed . |
| 23 | S&F for 35 mm thick factory made wooden flush door shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and directed . |
| 24 | S & F 30 mm th.Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges offraming plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters asspecified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats complete all as specified and directed. |
| 25 | All as per item No above if windows, ventilators, etc. Are provided with stiles and rails as specified in SSR Part I, Section 8 clause 8.24(b) supplied and fitted to chowkats complete all as specified and directed. |
| 26 | M&L preparation of new wooden surfaces and applying two coats of synthetic enamel paint over one coat of pink primer over 10 cm width or girth complete . |
| 27 | M&L preparation of old painted wooden surfaces and applying one coat of synthetic enamel paint over 10 cm width or girth complete . |
| 28 | M& L for Preparation of new iron surface and two coat of synthetic enamel paint ovar a coat of red oxide primer complete all as specified and directed. |
| 29 | M& L for Preparation of old iron surface and applying one coat of synthetic enamel paint complete all as specified and directed. |
| 30 | S & F 200 mm long Aluminium, anodised, barrel tower bolts of extruded section complete all specified and as directed. |
| 31 | S&F 150 mm size aluminium handles, cast type anodised completed all as specified and directed. |
| 32 | S&F stainless steel butt hinges 100mm size cold rolled medium weight and fixed complete all as specified and directed. |
| 33 | S&F 300mm size aluminium alloy anodised sliding door bolt with hasp & staple (bolt type) and fixing clip of sheet, cast or extruded sections and fixing bolt and sliding bolt of extruded section or cast alluminium alloy complete all as specified and directed. |
| 34 | Demolition of stone slab and tiles of any description and thickness in floors, aprons etc laid and pointed in any mortar, complete all as specified. |
| 35 | M & L Machine pressed precast concrete (rubberised form) interlocking paver block any shape and size confirming to IS-15658-2006 of 60mm thickness M-35 Grade, pointed with grey cement and no pigments, as in path etc laid over including 25 mm thick sand cushioning of existing PCC surface under floors or pavers, including watering and consolidation all as specified and directed by Engr-in-Charge. |
| 36 | M & L for 75 mm thick cement concrete (1:3:6), type C-2 using 40mm graded stone aggregate as in floors, hard standing etc and laid complete and finished the even & fair and all as specified and directed |
| 37 | S & F for Galvanised mild steel wire cloth 0.56 nominal dia of wire and average width of aparture 1.18mm and fixed with tinned tacks or galvanised wire staples, complete all as specified. |
| 38 | Dismantling timber scantlings 40 sq. cm and over in section, in any position complete all as specified and directed. |
| 39 | S & F in repairs 4mm thick E-Board tiles for insulation and acoustic purpose of size 600x 600mm fixed with and including anodised GI prepainted snap grid with 22x25x1.5 mm thick Tee section and 25x25x1.5 mm thick angle with hanging/supporting arrangements as in false ceiling at bottom at spacing 60 cm centre to centre including necessary GI cleats and 4mm dia GI wire as suspender fixed to ceiling not exceeding 1.20 mtr centre both ways with dash fastners complete and making good disturbed surfaces including taking down old ceiling complete all as specified and directed. |
| 40 | Dismantling of Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings complete all as specified and directed. |
| 41 | S&F prepainted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering / clading to wall, fixed with self tapping screws as specified. Complete all as spd and directed. |
| 42 | S & F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ridge / cladding to wall, fixed with self tapping screws as specified for Asbestos cement two pieceadjustable plain wing ridge 6mm thick Fixed with L-type or Jtype or cranked hook bolts Complete all as spd and directed. |
| 43 | S&F Steel work in Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel, hollow circular section or flat sections ) including distance pieces, cleats, nut bolts etc complete all as specified and directed. |
| 44 | Taking down carefully unserviceable copper/aluminium point wiring (Light, fan, socket or power) complete including unserviceable fittings and fixtures such as switches, ceiling roses, pendents, regulators, sockets, lamp holders, brackets, except ceiling fittings, bulk head fittings, tube light fittings etc. and making good the disturbed surfaces of walls, floors, etc. complete all as specified and directed. |
| 45 | Drawing out old sub main copper/aluminium cable off various sizes from existing conduit/ batten complete. |
| 46 | Taking down old MCB DBs/ main switches off size complete all as specified and directed |
| 47 | Material and labour for point wiring with single core FRLS 1100 volt grade cable with multi stranded copper conductor of size 1.5 Sq mm (Nominal area) drawn through and including non metallic rigid PVC conduit medium duty ISI marked not less than 20mm dia, with all conduit accessories, screws (concealed conduit wiring in walls and casing capping on ceiling or roof) including metal box suitable for modular fittings and covered with modular plate and cover of suitable size with new brass screws for mounting switch sockets and regulators and drawing continuous earth wire with and including PVC sheathed 1100 Volts grade cable with stranded copper conductor of size 1.5 Sq mm (Nominal area) and connected to main earth dolly complete all as specified for:- |
| 48 | (a) All as per item 48 here in before but One light / fan/ exhaust fan point controlled by one switch. |
| 49 | (b) All as per item 48 here in before but One 5 pin 5 Amp switch socket out let point on an independent board. |
| 50 | (c) All as per item 48 here in before but One 5 pin 5 Amp socket out let point controlled by one switch on same board. |
| 51 | All as per item 48 here in before but for one 15 Amp 6 Pin switch socket out let independent with 2.5 Sqmm FRLS (Nominal Area) PVC unsheathed copper conductor single core multistranded incl 2.5 sq mm FRLS PVC copper conductor single core used as earth continuity conductoe complete all as specified.complete all as specified. |
| 52 | S & F Modular switch one way 6 A, 1 Module complete all as specified and directed by the Engr-in-Charge. |
| 53 | S & F Modular switch one way 16 A, 1 Module complete all as specified and directed by the Engr-in-Charge. |
| 54 | S & F Modular Socket 6 Amp, 2/3 Pin combined 2 Module complete all as specified and directed by the Engr-in-Charge. |
| 55 | S & F Modular Socket 6/16 Amp, 2/3 Pin combined 2 Module complete all as specified and directed by the Engr-in-Charge. |
| 56 | S & F Modular fan regulator Step up type, 120 Watt, 2 Module complete all as specified and directed by the Engr-in-Charge. |
| 57 | Supply and Fixing ceiling rose PVC / Poly carbonate, Isolated body, three terminal AC 230 volts complete all as specified and directed. |
| 58 | S&F, in repairs, LED light fitting, high lumens batten type, housed in extruded from powder coated aluminium, 20 watt for soft diffuser lighting with and including lamp and connecting up complete with white PVC insulated and PVC sheathed round flexible three core copper conductor cable of suitable size and testing on completion all as specified and directed. Please Enable Macros to View BoQ information |
| 59 | S&F, in repairs, LED light fitting, high lumens batten type, housed in extruded from powder coated aluminium, 20 watt for soft diffuser lighting with and including lamp and connecting up complete with white PVC insulated and PVC sheathed round flexible three core copper conductor cable of suitable size and testing on completion all as specified and directed. Please Enable Macros to View BoQ information |