Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | CIVIL WORK |
| 2 | Earthwork in excavation in all types of soil for site leveling, foundation, pits, trenches and other civil works upto and including 1.5metre depth and stacking the soil upto a lead of 100 metre and including dewatering, removing slush, shoring and strutting (as required), complete as per specification and as directed by the Engineer-In-Charge. |
| 3 | Filling at all depth with available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 15cm in depth: consolidating each deposited layer by ramming and watering complete (lead upto 100m) as directed by the Engineer-In-charge. |
| 4 | Supplying of filling sand in foundation and over areas including watering, ramming, consolidating and dressing, labours, tools, taxes etc., all complete as per the specification and direction of Engineer-In-Charge. |
| 5 | Transportation by mechanical means within 5km from the work site |
| 6 | Providing and laying plain cement concrete of proportion (1:3:6) in foundation and floors using 4 cm. size black hard crusher broken granite stone metal and screened and washed sharp sand for mortar of approved quality and from approved quarry including hoisting, lowering, laying concrete, ramming, watering and curing etc. complete to required levels laid in layers not exceeding 15 cm. thick in each layer including cost, conveyance, royalties and cost of all labours,labour cess, T&P etc complete as per specification & direction of the Engineer-in-charge. |
| 7 | First class Fly ash Brick masonry using bricks of size 25cm. x 12 cm. x 8 cm. having crushing strength not less than 75 kg. Per. Sqr. Cm. in cement mortar of mix( 1:6) with ordinary Portland slag cement(PSC) and screened & washed sand for mortar after immersing the bricks for 6 (Six) hours in water before use in Foundation & Plinth including splays cutting, circular moulding, corbelling, chamfering and similar such type of works, watering and curing etc. including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, scaffolding, sundries, T&P required for the works etc. complete in all respect as directed by the Engineer-In-Charge. |
| 8 | Providing and laying in position ready mixed M-25 grade concrete having compressive strength at 28 days test not less than 250 kg/ sq.cm for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and excluding reinforcement including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, and hoisting, lowering, laying and compacting concrete, watering and curing and finishing the exposed surfaces smooth with cost, conveyance, royalties, taxes of all materials with all labour,Labour cess and T&P required for the work improve workability without impairing strength and durability as per direction of the Engineer - in - charge. |
| 9 | FOUNDATION & PLINTH |
| 10 | PEDESTAL |
| 11 | Coloum from Pedestal top to NGL |
| 12 | Coloumn from NGL tp PL |
| 13 | Plinth Beam |
| 14 | GROUND FLOOR |
| 15 | Coloum from PL to Ground floor Roof |
| 16 | Roof Beam |
| 17 | Roof Slab |
| 18 | Lintel |
| 19 | Chajja |
| 20 | Cutting,straightening coiled or bent up HYSD/TMT 550D Reinforcement Bars confirming to IS 1786:2008 welding or jointing if necessary ,bending, binding,tying the grills as required for R.C.C. works,providing Fan Hooks where necessary and hoising,lowering and placing the same tin proper position according to the approved designs and drawings in all floors including cost, conveyance, loading, unloading and taxes or HYSD/TMT Reinforcement Bars and Binding wieres of 18 to 20 gauge required for the work cost of all labour,T&P and scaffolding complete in all respect as directed by the Engineer-in-charge(Payment will be made according to the actual/proper weight of HYSD/TMT Reinforcement Bars and Binding wires consumed in the particular work only) |
| 21 | Foundation & Plinth |
| 22 | GROUND FLOOR |
| 23 | Fly Ash Brick Masonry in cement mortar of mix (1:6) using Fly Ash bricks of size 25c.m x 12 c.m x 8 c.m in Super structure having crushing strength not less than 75 kg per square c.m. with cement and screened & washed sharp sand for mortar after immersing the bricks for 6 (Six) hours in water before use in works with all necessary projections, splays cutting, circular moulding, corbelling, chamfering, watering and curing etc. including cost, coveyance,stacking, loading, unloading, royalties , all taxes ,cost of all labour,Labour cess ,scaffolding, sundries and T&P required for the works etc. complete in all respect as directed by the Engineer-in-charge. |
| 24 | Ground floor |
| 25 | Terrace Floor |
| 26 | Fly Ash Brick Masonry in cement mortar of mix (1:4) using Fly Ash bricks of size 25c.m x 12 c.m x 8 c.m in Superstructure having crushing strength not less than 75 kg per square c.m. with cement and screened & washed sharp sand for mortar after immersing the bricks for 6 (Six) hours in water before use in works with all necessary projections, splays cutting, circular moulding, corbelling, chamfering, watering and curing etc. including cost, coveyance,stacking, loading, unloading, royalties ,all taxes ,cost of all labour,Labour cess ,scaffolding, sundries and T&P required for the works etc. complete in all respect as directed by the Engineer-in-charge. |
| 27 | Ground floor |
| 28 | Providing 12 mm thick cement plaster with cement mortar of mix (1:6) with screened and washed sharp sand for mortar and finished smooth to the rough surface of walls in all heights after racking out joints including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance, royalties, with cost of all labour,labour cess, T&P, and scaffolding required for the work etc. complete in all respect and specification and direction of the Engineer in charge. (External wall) |
| 29 | Ground Floor |
| 30 | Terrace floor |
| 31 | Providing 12 mm thick cement plaster with cement mortar of mix (1:6) with screened and washed sharp sand for mortar and finished smooth to the rough surface of walls in all heights after racking out joints including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance, royalties, with cost of all labour,labour cess, T&P, and scaffolding required for the work etc. complete in all respect and specification and direction of the Engineer in charge. (Internal wall) |
| 32 | Ground Floor |
| 33 | Providing 16mm. Thick cement plaster in cement mortar or mix(1:6) in all floors at all height with cement & screened and washed sharp river sand for mortar and finished smooth to the rough surface of the brick masonary walls after racking out the joints (alongwith providing grooves wherever necessary)including watering and curing, rounding of corners etc. complete with cost,conveyance,loading, unloading, royalities and taxes of all materials,cost of all labour,T&P and scaffolding required for the work etc. as directed by the Engineer-in-charge. |
| 34 | Ground Floor |
| 35 | Terrace Floor |
| 36 | Providing 6 mm thick cement plaster with cement mortar of mix (1:4) with screened and washed sharp sand for mortar and finished smooth to R.C.C. work after closed deep chipping & slurry treatment including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance and royalties of all materials with cost of all labour, T&P, and scaffolding required for the work etc. complete in all respect as directed by the Engineer in charge. |
| 37 | Ground Floor |
| 38 | Finishing plastered surfaces of walls with cement based wall putty (Water based) of approved make and finishing the surface smooth and even by sand papering to receive painting in walls, at all heights with staging wherever necessary with cost, conveyance, all materials, cost of all labour,labourcess, all T&P etc. required for the work complete in all respect as per the direction of the Engineer-in-charge. |
| 39 | Ground Floor |
| 40 | Terrace Floor |
| 41 | Priming one coat with water bound wall primer. |
| 42 | Ground Floor |
| 43 | Terrace Floor |
| 44 | Distempering two coats to walls with distemper of approved shade on new work to give an even shade |
| 45 | Ground Floor |
| 46 | Terrace Floor |
| 47 | Wall painting two coats with Weather coat paint (1st quality) exterior grade of approved make & with a approved quality primer to make an even finished surface in all floors and heights with all scaffolding and staging charges including cost, conveyance, cost of all labours, T & P, sundries etc. as required for the work complete in all respect as per the direction of the Engineer-in-Charge. |
| 48 | Ground Floor |
| 49 | Terrace Floor |
| 50 | Providing 16mm. thick finished Kota stone flooring using kota stone of approved quality, colour and size above 0.10 sqm in floors, treads on steps and landing on 20mm. thick bed of cement mortar mix of (1:4) with screened and washed sharp river sand for mortar and cement of approved quality, grouted with neat white cement slurry laid in proper slope joining the Kota stone with neat white cement slurry mixed with required quantity of pigment of approved marks to match the shades of the kota stone to kota colour if required, watering and curing for the required period , including cost, conveyance, loading, unloading, royalties, and taxes of all materials, cost of all labour, sundries, T&P required for the work including cost of rubbing mechanically and wax polishing etc complete in all floors at all height in all respect as directed by the Engineer-in-charge. |
| 51 | Ground Floor |
| 52 | Providing 16mm. thick finished kota stone in dado/skirting using kota stone slab above 0.10 sqm of approved quality, colour and size in dado, risers of steps on 12mm. thick bed of cement mortar mix of (1:3) with screened and washed sharp river sand for mortar and cement of approved quality, grouted with neat white cement slurry laid in proper slope mixed with required quantity of pigment of approved marks to match the shades of the kota tiles to kota colour if required, watering and curing for thr required period, including cost, conveyance, loading, unloading, royalties, and taxes of all materials, cost of all labour, sundries, T&P required for the work including rubbing mechanically and wax polishing etc. in all floors at all height complete in all respect as directed by the Engineer-in-charge. |
| 53 | Ground Floor |
| 54 | Supplying, fitting and fixing of Antiskid Ceramic Floor Tiles in flooring using special plain / printed series Ceramic Floor Tile of premium grade ( having minimum thickness 7 mm to 8 mm & size 400 mm x400 mm, confirming to I.S 13755 of approved quality and shade in floors, treads on steps and landings on 20 m.m thick bed of cement mortar of mix (1:4) laid in proper slope and gradient with screened & washed sharp river sand for mortar and fixing with neat white cement slurry,grouting the joints with neat white cement slurry mixed with required quantities of pigments (Tiles are to be immersed in the water for required time before use) of approved make to match the shades of the Ceramic Floor Tiles if required including cost, conveyance, loading, unloading, stacking, royalties , all taxes,rubbing, cost of all Labour, Labour cess ,Sundries, T&P required for the work , Watering , Curing for required days , cleaning the flooring space manually etc. complete in all respect as directed by the Engineer-in-charge. |
| 55 | Ground Floor |
| 56 | Supplying, fitting & fixing of 30cm x 20cm/20cm x 20cm special plain/printed series Ceramic wall tiles of premium grade having thickness 6.5mm to 6.7mm confirming to IS 13753 laid on 12 mm thick cement mortar (1:3) (1 cement : 3 course sand) jointed with slurry mixed with pigment to match the shades of the tiles etc. complete including cost of all materials, labour T&P etc. required for the work all complete as per direction of the Engineer-in-charge. |
| 57 | Ground Floor |
| 58 | Providing and fixing of Aluminium sliding window with Acrylic sheet |
| 59 | Ground Floor |
| 60 | Providing and fixing of Aluminium Ventilator with Acrylic sheet louver |
| 61 | Ground Floor |
| 62 | Providing and fixing of dressed seasoned sal wood Door choukath including all labour, material, fitting & fixtures etc all comlete as per direction of EIC |
| 63 | Ground Floor |
| 64 | Providing & fixing ISI marked 35mm thick Flush door shutter confirming to IS:2202 (part 1), decorative type core of block board constrution with frame of 1st class hard wood and well matched teak three ply veneering with vertical grains or cross bands and faced veneers on both faces of shutters of approved design including cost of all door fittings and fixtures etc. complete |
| 65 | Ground Floor |
| 66 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) Solid door/ window/ Ceosetory windows & other Frames/Chowkhat (Graphite grey colour) comprising of virgin PVC polymer of K value 58-60 (Suspension grade),calcium carbonate & natural fibers (wood powder/rice husk/wheat husk) and nontoxic additives (maximum toxicity index of 12 for 100 gms ) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face)& 1100 N (Edge), minimum compressive strength of 58N/mm2, modulus elasticity 900N/mm2 and resistance to spread of flame of class A category with property of being termite/borer proof etc |
| 67 | Ground Floor |
| 68 | Providing and fixing factory made single extruded 30 mm thick WPC solid decorative type Flush door shutter with paint finish of required size comprising of virgin polymer of K value 58-60calcium carbonate and natural fibers and non-toxic additives having minimum density of 650kg/cum and screw withdrawl strength of 1800N (FACE) & 900N (Edge) minimum compressive strength 50 N / MM2,modulus of elasticity 850N/mm2, and resistance to spread of flame of class A Category with property of being termite/borer proof , water / moisture proof and fire retandant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melted adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk SS screw,SS Handle, Door stopper, SS Hinges, Sliding door bolt etc. all as per direction of EIC. (Make: Century /Floresta/ ALSTONE) |
| 69 | Ground Floor |
| 70 | Supplying and Fixing of M.S. Window Grill made out of M.S Flat conforming to IS 2062/2006 excluding the cost of Red Oxide Primer as per the design approve by E.I.C including cost, conveyance of all materials,priming,and labour for fitting fixing etc.complete as per the instruction of Engineer-in-Charge |
| 71 | Ground Floor |
| 72 | Painting two coat with approved synthetic enamel paint to new wood & iron work over a coat of primer including cost, conveyances, royalties of all materials and cost of all labour with T&P required for the work etc. complete as per specification & direction of Engineer in charge. |
| 73 | Ground Floor |
| 74 | Supplying, fitting and fixing of Stainless steel of 304 grade in hand railing using 50mm dia of 2mm thick circular pipe with Balustrade of size 32mm x 32mm x 2mm @ 0.90mtr. C/C and stainless square pipe bracing of size 32mm x 32mm x 2mm in 3 rows in stair case as per approved design and specification, buffing, polishing etc with cost, conveyance, cost of all labour,labour cess, T&P etc. required for the work complete in all respect as per direction of the Engineer-in-charge. |
| 75 | Ground Floor |
| 76 | 20MM thick Grading Plaster |
| 77 | Making plinth protection 50mm thick of cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well ramed, consolidated and grouted with fine sand and finishing the top smooth including shuttering at the edges, excavation and disposing of surplus earth with a lead of 100m complete as per direction of Engineer-in-charge. |
| 78 | INTERNAL P.H. & SANITARY WORK. |
| 79 | WATER SUPPLY. |
| 80 | Supplying, installing, fixing, jointing, testing and commissioning of approved make. Chlorinated Polyvinyl Chloride pipes (CPVC) SDR.11 pipes confirming to ASTM standards with necessary fittings for inetrnal toilet water supply upto 50 dia , and above 50mm dia pipe schedule 40 with fitting shall be schedule 80 ASTM IPS. The fittings and specials such as tees, elbows,couplers, bends, enlargers etc.,m with CPVC brass threaded combination / transition specials such as male adapters brass threaded female adapters, brass FPT Tee, Brass FPT elbow etc., where connection with metal is to be made including necessary drilling holes, chasing walls and making the same good in cement martor 1:1 restore the same original condition neately as directed by the Engineer in-charge. Joints to be made with CPVC solvent cement up to 50mm dia as per ASTM D-2846 and above 50mm dia primer P-70, and solvent confirming to ASTM F-4931 / 724 All exposed pipe shall be painted with latex paint. (for shafts, basement ceiling ringmain Terrace & PRM).The rate shall include necessary GI supports, GI grip bolts, angle brackets, hangers, supports as with suitable GI U-clamps, bolts, nuts and washers etc., The clamps shall be painted with two coats of enamel (approved) paint over a coat of primer etc., complete. Make:- Supreme/Ashirbad/AKG. |
| 81 | 20 mm dia C-PVC pipe (Oriplast/Supreme) |
| 82 | 25 mm dia C-PVC pipe (Oriplast/Supreme) |
| 83 | 32 mm dia C-PVC pipe (Oriplast/Supreme) |
| 84 | 40 mm dia C-PVC pipe (Oriplast/Supreme) |
| 85 | supplying all materials, labour, T&P and cutting holes through existing brick work including making good the damages in cement mortar (1:4) for taking G.I. Pipes and fittings/ P.V.C. pipes and fittings etc. all complete as per P.H. specification and direction of Engineer-in-charge. 250 mm thick wall |
| 86 | Supplying all materials, labour, T&P and cutting grooves in pucca floors and walls for taking G.I./P.V.C. pipes and making good the damages as per direction of the E.I.C. |
| 87 | SANITARY FIXTURES. |
| 88 | Supplying all materials, labour, T&P and fixing the following vitreous china Wash Down Water Closet (European type W.C. pan) of Hindware/Jaquar/Parryware with integral 'p' or 's' trap to the floor with wooden plug and chromium plated pedestal screws including jointing the trap with soil pipe in cement mortar (1:1) fixing plastic seat and cover for wash down water closet with chromium plated brass hinges and rubber buffers including polishing etc all complete as per specification and direction of the Engineer-In-Charge. (EWC with Wall Hung Cistern, Drainage L Bend Pipe, Gasket and Installation Kit with PP normal close seat cover, Hinges, Fixing Accessories and Accessories set, Size: 350x480x395 mm, STrap) |
| 89 | CNS-WHT-551SNPP184LZ (Make: Jaquar) |
| 90 | Supplying all materials, labour, T&P and fixing Health Faucet of Hindware/Jaquar/Parryware complete with Chromium plated brass brackets fixed to wooden plugs with Chromium plated brass screws as per specification and direction of the Engineer-In-Charge. |
| 91 | JAQUAR-ALD-577 Hand Shower (Health Faucet) with 8mm Dia, 1.2 Meter Long Flexible Tube & Wall Hook with N.R.V (Back Flow Preventer) |
| 92 | Supplying all materials, labour, T&P and fixing standard sized Bib cock of Hindware/Jaquar/Parryware of approved make etc complete including cutting the wall and making good the damages, including cost of all materials complete as per PH specification complete as per direction of Er-in-charge. 15mm dia CP Two way bib cock with Flange.(HINDWARE Cat. No.: F730041) |
| 93 | Supplying all materials, labour T&P and fixing HALF Pedestal type wash basins of Hindware/Jaquar/Parryware with hole for pillar taps with cast iron or M.S.brackets painted white including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc, fixing pedestal for wash basin recessed at the back for the reception of pipes and fittings, fixing PVC waste pipe of 32mm nominal diameter for wash basin including brass check nut complete, fixing pillar taps capstan head screw down high pressure lettered 'Hot' and 'Cold' with long screws, shanks and back nuts of 15mm dia nominal bore, fixing 15mm dia PVC inlet connection pipe and making connection with pillar cocks and supply mains for wash basin, fixing 32mm dia CP brass waste, etc all complete as per specification and direction of the Engineer-In-Charge. |
| 94 | Jaquar ARS-WHT-39305 |
| 95 | Supplying all materials, labour, T&P and fixing standard sized Chromium Plated Shower of Hindware/Jaquar/Parryware complete with Chromium Plated brass brackets fixed to wooden plugs with Chromium Plated brass screws as per specification and direction of the Engineer in charge. SHOWER HEAD,SHOWER ARM,ANGULAR STOP COCK |
| 96 | Supplying all materials, labour, T&P and fixing standard sized pillar cock of Hindware/Jaquar/Parryware of approved make etc complete including cutting the wall and making good the damages, including cost of all materials complete as per PH specification and direction of Engineering-in-charge. 15mm dia fus Jaquar,Cat No- PRS-031 |
| 97 | Supplying all materials, labour, T&P and fixing mirror of superior glass mounted on 6mm thick A.C.sheet or plywood sheet and fixed to wooden plugs with CP screws and washers complete as per specification and direction of the Engineer-in-charge. 600mmx450mm size B.E.mirror (Alpina/Golden fish/Belgion) |
| 98 | Supplying all materials, labour, T&P and fixing standard sized Robe Hook of Hindware/Jaquar/Parryware complete with all as per specification and direction of the Engineer in charge. Jaquar ACN-1161N |
| 99 | Supplying all materials, labour, T&P and fixing standard sized 15mm dia angular Stop cock of Hindware/Jaquar/Parryware of approved make etc complete including cutting the wall and making good the damages, including cost of all materials complete as per PH specification complete as per direction of Er-in-charge. 15mm dia CP angle stop cock with wall flange .jaquar,Cat No-CQT-23059 |
| 100 | Supplying all materials, labour, T&P and fixing standard sized Chromium Plated soap case Hindware/Jaquar/Parryware complete with Chromium Plated brass brackets fixed to wooden plugs with Chromium Plated brass screws as per specification and direction of the Engineer in charge. |
| 101 | Fixing of 32mm dia Brass/GM Fulway Valve confirming to IS : 781-1995 of approved make as per specification complete as per direction of Er-in-charge. 32mm dia brass or gun metal full way valve.(Make- Zoloto or equivalent.) |
| 102 | Fixing of 25mm dia Brass/GM Fulway Valve confirming to IS : 781-1995 of approved make as per specification complete as per direction of Er-in-charge. 32mm dia brass or gun metal full way valve.(Make- zoloto or equivalent.) |
| 103 | Fixing Rotational moulded Poly Propelene double layer cylindrical vertical water storage tanks confirming to IS 12701-1996 including cutting holes through the tank and fixing mild steel tubes and fitting and providing extra sockets and jam nuts, fixing ball valve etc,including hosting upto a height of 5 mtr above ground level and placing the tank to the required postion etc all complete as per specification and direction of the Er-in-charge. (2000 Ltr) |
| 104 | Supply all materials, labour, T&P and providing fitting & fixing (Aqua guard) pure Chill 80 PSS UV of size 750x570x1350 mm height with water storage capacity 80 liters along with 2 nos of fancets 1 for cold water and 1 for normal water including a flow of 1.5 ltr per minute etc. all complete as per approved drawing, specification and direction of the EIC. |
| 105 | Supplying all materials, labour, T&P and fittings & fixing stainless steel ASIS 304 (18/8) kitchen sink with drain board as per IS 13983 with cast iron or MS brackets painted white including cutting holes in walls and making good the damages etc all complete as per specification and direction of the Engineer in charge. (600x450x250mm stainless steel kitchen sink) |
| 106 | Providing & fixing of 15mm dia CP Sink cock (Jaquar)FLR-CHR-5347N |
| 107 | SEWAGE SYSTEM. |
| 108 | Supplying all materials, labour, T & P and constructing of Inspection chamber of the following inside size with 8 cm thick R.C.C. precast cover slab in CC (1:2:4) mix using 12mm size h.g. chips, foundation concrete (1:4:8) using 40mm size h.g. metal on bed aound trap , Fly Ash brickwork in CM (1:6) in P&F and inside 12mm thick cement plastering (1:3) finished with a floating coat of neat cement including fixing 100mm x100mm size gully trap, 150mm x150mm C.I gratig etc. all complete as per aproved drawing, specification and direction of Engineer-in-charge. |
| 109 | Size- 600 x 600 x 450 mm |
| 110 | Providing and fixing square mouth S.W GULLY TRAP(G T) class SP-1 complete with CI grating brick masonry chamber with water tight CI cover with frame of 300X300mm size (inside),the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per the standard desifn. brick masonry chamber of size 180 X 150 mm size complete as per approved specification and direction of the Engineer in charge |
| 111 | Size- 300x300 mm |
| 112 | Supplyijn g all material, labour, T&P & constructing men hole chamber (MH) of the following indise size with 8 cm thick RCC pre casr cover slab in CC (1:2:4) mix using 12mm size hg chips foundation concerete 1:4;8 using 40 mm size hg metal on bed round trap , fly ash brick work in CM 1:6 in P&F & inside 12mm thicCM 1:3 finished with a floating coat of net cement including fixing 100mm x 100 mm size gully trap , 150mm x 150mm CI grating etc all complete as per approved drawing, spwecrification & direction of the Engineer-in-charge (Main hole chamber of size 1200 x 900 x 900 mm) |
| 113 | Supplying, fixing and testing PVC soil, waste, Rain and vent pipes (SWR) SUPREME confirming to IS13592 : 1990, type B with rubber ring/Solvent (confirming toIS5382) joint inclusive of allnecessary specials like bends, tees,offsets, door bends, junctions, cowls, etc.,laid underfloor/ fixed on walls,and in pipe shafts etc., complete.The rate shall include necessary GI supports, GI grip bolts, angle brackets, hangers, supports as with suitable GI U-clamps, bolts, nuts and washers etc., The clamps shall be painted with two coats of enamel (approved) paint over a coat of primer etc., complete. Make:- Supreme/Ashirbad/Astral/Sentini |
| 114 | 40 mm dia .ASTRAL-M081060304 |
| 115 | 75 mm dia .(ASTRAL -M341110307) |
| 116 | 110 mm dia .(ASTRAL -M341110309) |
| 117 | 160 mm dia Rain pipe. ( SENTINI FLOW PIPE BS0009SP3M) |
| 118 | Supplying, fixing and testing PVC muilty floor trap with SS frame and cover 75mm dia outlet fixed on a bed of cement concrete with (Heavy duty type) etc., complete. MAKE- Astral-M252003236 |
| 119 | 110 mm dia (SENTINI NM5609SFPL) |
| 120 | Providing ,fixing , testing and commissioning of approved make PVC vent cowl with necessary accessories etc., complete. Make-Astral,page-06 |
| 121 | 75 mm dia (ASTRAL -M212002707) |
| 122 | 110 mm dia (ASTRAL -M212002709) |
| 123 | Providing and fixing Clean Out |
| 124 | 75 mm dia (SENTINI SF1007SFPL) |
| 125 | 110 mm dia (SENTINI SF1009SFPL) |
| 126 | Sub-Head I (modular Wiring Items) |
| 127 | Recessed wirring to light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor (Make-Havells/Polycab/ Finolex/RR Kable ) of ISI marked with 20 mm dia PVC heavy class FRLS non metallic conduit(Make-AKG/Polycab/precision/norpack/ sudhakar) with 6A modular type switch(Make-Legrand(Myrius), Schneider (Zencelo), Panasonic (Vision) ) ISI marked , and ceiling rose ISI marked of modular type G.I box with cover , of suitable size, modular box with 1.5 sq. Mm FRLS PVC insulated single core multistandard copper conductor as earth wire including all accessories and connection .Raw power supply switch board shall be separate from emergency power supply switchboard as per direction of Engineer -in -Charge. Each light point should have provision for ceiling rose & angle holder point. |
| 128 | GROUP-A(QTRS) |
| 129 | GROUP-B(QTRS) |
| 130 | GROUP-C(COMMON ARAE) |
| 131 | Supplying ,fixing of 6A Plug on the same board in existing switch board with complete fitting by 01 no of 6A switch & socket (modular type)(Make-Legrand(Myrius),Schneider(Zencelo),Panasonic(Vision) & other required accessories of ISI marked as approved as per direction of Engg. -in -Charge. |
| 132 | Supplying,fixing of 6A Plug on the separate board with complete fitting by 01 no of 6A switch & socket(modular type)(Make-Legrand(Myrius),Schneider(Zencelo),Panasonic(Vision) with suitable size modular box & cover including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge. |
| 133 | Supplying,fixing of 16A Plug on the separate board with complete fitting by 01 no of 6A switch & socket(modular type) (Make-Legrand(Myrius),Schneider(Zencelo),Panasonic(Vision) with suitable size modular box & cover including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge. |
| 134 | Receass wiring for circuit/submain wiring with the following mentioned size PVC insulated, copper conductor FRLS, single core cable (Make-Havells/Polycab/Finolex/RR Kable/KEI/Gloster) in recessed PVC FRLS conduit HEAVY duty (Make-AKG/Polycab/precision/norpack/sudhakar) of mentioned size as approved) as required as per direction of Engg.-in-Charge.. |
| 135 | 2 nos single core 1.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor. In 20 mm dia non metallic FRLS heavy duty conduit (LDB to LSB/LIGHT CKT)(2X1.5+1X1.5) |
| 136 | 2 nos single core 2.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic FRLS heavy duty PVC conduit.(BDB to LSB/LIGHT CKT/5A PLUG/INVERTER POINT TO EACH QTR) (2X2.5+1X1.5) |
| 137 | 2 nos single core 4 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic FRLS heavy duty PVC conduit . (2X4+1X1.5) |
| 138 | 2 nos single core 6 sq. mm copper wire for phase and neutral and 01 no of single core 2.5 sq. mm copper wire for earth continuty conductor in 25 mm dia non metallic FRLS heavy duty PVC conduit .(PANEL TO BDB EACH QTR) (2X6+1X2.5) |
| 139 | Supplying and installation of 25A AC starter Modular type or any other equivalent reputed make as approved coil voltage-415 Volt A.C. & O/L range of suitable range range on mod Box of suitable size including modular coveras required as per direction of Engg.-in-Charge .(Make-Legrand/Schneider/ Havells/ABB) |
| 140 | Supply and fixing CALL bell (Ding dong type) /Buzzer on the existing switch box/cover. as required as per direction of Engg.-in-Charge. (Make-Legrand(Myrius),Schneider(Zencelo),Panasonic(Vision) |
| 141 | S/F of Bakelite angle holder/batten holder (make-Anchor/Havells of ISI marked conforming to IS-1258/1987 in place of ceiling rose as per direction of Engg.-in-Charge . |
| 142 | S/F of 5 step type Modular electronic Fan Regulator ISI Marked with all connection complete in all respect as per direction of Engineer in charge ( Make-Schneider(Zencelo)/legrand( Myrius)/Panasonic (vision) |
| 143 | Sub-Head II (Light fitting Fixture & Fan) |
| 144 | Supplying, installation, of exhaust fan of heavy duty 300 mm sweep with louvers any other equivalent reputed make star rated as approved) of exhaust fan in the existing wall, including fixing & conntection as required as per direction of Engg.-in-Charge. Replacement warranty shall be 2 years. Make-Havells/Bajaj/Usha/Crompton /Orient |
| 145 | Supplying, installation, testing and commssioning of 1200 mm sweep BLDC ceiling fan with aluminium blades having wattage not more than 28W and Air delivery ≥ 215(m3/min) Make-USHA(Technix)/Crompton(Energion Groove)/Havells(Efficiencia Neo ) including wiring the down rod of standard length (upto 30 cm) with 1.5 sq mm PVC insulated, copper conductor, single core cable etc. as required as per direction of Engg.-in-Charge,Replacement Warranty will be 4 years.. . |
| 146 | SITC of energy efficient LED tube light fittings with decorative alumunium LED batten along with LED tube light having power rating 20 watt and lumen output not less than 2200 lumen complete with electronic driver and all other accessories with diffuser i/c connection etc as required.The luminaire should be Replacement Warranty will be 2 years panasonic/havells/LT/Bajaj/Phillips/Crompton/Wipro |
| 147 | SITC of Sleek LED 10 watt mirror light fitting with decorative aluminium LED batten having extruded polycarbonate housing,High optically efficient diffuser,above wash basin complete with all accessoriesetc. directly on wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.The luminaire should be Replacement Warranty will be 2 yearspanasonic/havells/LT/Bajaj/Phillips/Crompton/Wipro |
| 148 | SITC of Sleek LED 9 watt LED Lamp complete with all accessories etc. directly on angle holder as required.The luminaire should be Replacement Warranty will be 2 years panasonic/havells/ LT/Bajaj/Phillips/Crompton/Wipro |
| 149 | Supply and fixing of 10 Watt LED BH Fitting.The luminaire should be Replacement Warranty will be 2 years (panasonic/ havells/LT/Bajaj /Phillips/ Crompton/Wipro) |
| 150 | Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as requiredas required as per direction of Engg.-in-Charge .(Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)of ISI mark as approved. |
| 151 | Supplying and fixing of Energy efficient surface /recess mounted square /round shape 18 W LED luminaire of dimension of consists of white powder coated , die-cast Alluminium housing with high quality frosted diffuser for glare-free uniform lighting distribution with wattage not more than 18 watt and lumen output of 1800 lumens, , CRI not less than 80,CCT of 6000 degree K,THD less than 10%, with electronic driver, internal surge protection of 3 KV , L70 B50: 50000 hrs and all other accessories suitable for operation on 220 V to 240 V supply as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj).The luminaire should be Replacement Warranty will be 2 years |
| 152 | Supplying ,installation ,testing & commissioning of 1 KVA ,240V UPS with all required accessories & suitable nos 12v battery,220Ah tubular type,battery rack as per the direction of Engineer in Charges.Make-V-guard/Microtech/Luminous . (only for common area) |
| 153 | BDBS,DB,AC DB,FLOOR PANELS,MCBS |
| 154 | Supplying and fixing of following mentioned way, three pole/single pole and neutral, sheet steel,double door MCB distribution board, 415 volts/240 volts shall be as per IEC 61439-3,integrated door earthing system offering additional safety to the user,High quality polyurethane Gasket,the box and cover shall be fabricated to withstand IK09,the DB should be properly pre-treated with 7 tank process and duly powder coated, phosphatized with powder coated finish, on surface/recess, complete with terminal blocks,with suitable size FR PVC insulated copper conducter up to terminal blocks, tinned copper busbar, neutral busbar, earth bar, din bar. Make-LEGRAND-Ekinox3 DB/ Siemens-Betaguard/ Schneider- Acti 9/ABB Itus as per direction of Engg.-in-Charge. The Distribution boards should be Replacement Warranty will be 3 years |
| 155 | Supply and fixing of 12 way DD single pole and neutral sheet steel MCB distribution board 250V on surface/recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required (but with out MCB/ RCCB/ Isolator) Warranty on DB is 3 years .(QTR & COMMON) |
| 156 | Supply and fixing of 8 way DD single pole and neutral sheet steel MCB distribution board 250V on surface/recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required (but with out MCB/ RCCB/ Isolator) Warranty on DB is 3 years (For Inverter and Servant quarters,1 no for lift) |
| 157 | Supplying and fixing 6 amps to 32 amps rating, 240 volts, C series,10KA breaking capacity, single poles MCB of Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 Model of ABB/LK/Hager/C&S/Havells/Panasonic. the existing MCB DB complete with connections as per direction of Engg.-in-Charge. .Warranty on MCB is 1 year. |
| 158 | Supplying and fixing 63 Amps rating,C series,10KA breaking capacity, 2P, 240 volts, RCCB 30mA . Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB FB 200 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. . The RCCB should be Replacement Warranty will be 1 year. |
| 159 | Supplying and fixing 25 Amps rating,C series,10KA breaking capacity, 2P, 240 volts, RCCB 30mA . Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB FB 200 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. . The RCCB should be Replacement Warranty will be 1 year. |
| 160 | Supplying and fixing 25 amps rating, 415 volts, C series,10KA breaking capacity, FOUR poles MCB of Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200/ABB SB 200 in the existing MCB DB complete with connections as per direction of Engg.-in-Charge. .Warranty on MCB is 1 year. |
| 161 | Supplying and fixing 32amps rating,double pole mcb type changeover 240 volts, C series,10KA breaking capacity, of Make-LEGRAND/ Siemens/ Schneider/ABB the existing MCB DB complete with connections as per direction of Engg.-in-Charge. .Warranty on MCB is 1 year.(raw source+solar) for commonarea light DB) |
| 162 | Supplying and fixing 6 amps to 32 amps rating, 240 volts, C series,10KA breaking capacity, DOUBLE POLE MCB of Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 Model in the existing MCB DB complete with connections as per direction of Engg.-in-Charge. .Warranty on MCB is 1 year. |
| 163 | Supplying and fixing 63 amps rating, 240 volts, C series,10KA breaking capacity, DOUBLE POLE MCB of Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 the existing MCB DB complete with connections as per direction of Engg.-in-Charge. .Warranty on MCB is 1 year. |
| 164 | (Earthing) INSTALLATION |
| 165 | S/IT/C Of Earthing withG.I earth plate 600 mm x 600mm x 6 mm thick ISI marked including accessories and providing masonary with cover plate having loccking arrangement and watering pipe etc (WITH charcoal and salt) as required as per direction of Engg.-in-Charge. |
| 166 | Providing and fixing 6 SWG G.I wire on surface or in recess for loop earthing as required.as per direction of Engg.-in-Charge. |
| 167 | Providing and fixing 25mm x 5 mm G.I strip on surface or in recess for connections etc. as required as per direction of Engg.-in-Charge.(DOUBLE RUN TO MAIN PANEL & APFC PANEL ,AC PANEL) |
| 168 | CABLING AND END TERMINATION MAIN AREA |
| 169 | Supplying of one number PVC insulated armoured and PVC sheathed AL. conductor power cable of 1.1 KV grade of following size cables as per direction of Engg.-in-Charge. make-polycab/finolex/Havells/RR Kabel/KEI/Gloster |
| 170 | 3.5core x 95 sq mm |
| 171 | 4core x 16 sq mm (LIFT,SERVICES,DG-2 RUNS) |
| 172 | LAYING OF CABLE |
| 173 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 25 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge. |
| 174 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size exceeding 25 SQ. MM but not exceeding 120 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge. |
| 175 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size exceeding 120 SQ. MM but not exceeding 400 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge. |
| 176 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 25 SQ. MM in surface with shaddle and screw etc as required as per direction of Engg.-in -charge. |
| 177 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 120 SQ. MM From 25 SQ. MM in surface with shaddle and screw etc as required as per direction of Engg.-in -charge. |
| 178 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 400 SQ. MM From 120 SQ. MM in surface with shaddle and screw etc as required as per direction of Engg.-in -charge. |
| 179 | Supplying and making end termination with brass comprecision gland and aluminium lugs for following mentioned size cable.as per direction of Engg.-in-Charge. |
| 180 | 3.5 core x95 sq mm |
| 181 | 4core x 16 sq mm (DG) |
| 182 | Providing,fixing and laying of fallowing dia G.I. pipe (medium class) in ground complete with G.I fitting incl. trenching(75 mm depth)and refilling as per direction of Engg.-in-Charge. |
| 183 | 50 mm dia |
| 184 | PANELS |
| 185 | MAIN METERING PANEL |
| 186 | Supplying,fixing of perforated cable trays with horizental & vertical bends,reducers ,tees,crossover,brakets & other accessories ar requited confirming to IS-IEC -61537 ,the cable tray shall be galvanised for corrosion protection confirming to DIN EN 10346/ISO 1461. Size 60mm(H) x 200mm(W) of MAKE- Profab/OBO/Neidax.The Load bearing capacity of the Cable Trays should be minimum of 104.8Kg/meter at the span of 1.5Meter as per UL specifications as required as per direction of Engg.-in-Charge. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail