| Sl. No. | Item Description |
| 1 | CIVIL WORKS |
| 2 | SITE CLEARENCE |
| 3 | Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees andsaplings of girth up to 30 cm measured at a height of 1 m above ground level andremoval of rubbish up to a distance of 50 m outside the periphery of the area cleared |
| 4 | EARTH WORK EXCAVATION WORKS |
| 5 | Earth work in excavation by mechanical means (Hydraulic excavator) /manual meansin foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan),including dressing of sides and ramming of bottoms, lift up to 1.5 m, includinggetting out the excavated soil and disposal of surplus excavated soil as directed,within a lead of 50 m.All kinds of soil |
| 6 | Filling available excavated earth (excluding rock) in trenches, plinth, sides offoundation etc. in layers not exceeding 20 cm in depth, consolidating each depositedlayer by ramming and watering, lead up to 50 m and lift up to 1.5 m. |
| 7 | Extra for every additional lift 1.5 m or part there of in excavation / banking excavatedor stacked materials.All kinds of soil |
| 8 | Filling with contractor's own earth ( excluding rock) in trenches, plinth, sides offoundations etc. in layers not exceeding 20 cm in depth, consolidating each depositedlayer by ramming and watering, lead up to 50 m and lift up to 1.5 m as per directionof site Engineer-in-charge |
| 9 | PCC WORKS |
| 10 | Providing and laying in position cement concrete of specified grade excluding thecost of centering and shuttering - All work up to plinth level:1:4:8 (1 Cement : 4coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mmnominal size derived from natural sources) |
| 11 | Providing and laying in position cement concrete of specified grade excluding thecost of centering and shuttering -All work above plinth level up to floor fivelevel1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) |
| 12 | RCC WORK |
| 13 | Providing and laying in position machine batched and machine mixed design mix M25 grade cement concrete for reinforced cement concrete work, using cement contentas per approved design mix, including pumping of concrete to site of laying butexcluding the cost of centering, shuttering, finishing and reinforcement, includingadmixtures in recommended proportions as per IS: 9103 to accelerate, retard settingof concrete, improve workability without impairing strength and durability as perdirection of Engineer - in-charge.All work upto plinth level. |
| 14 | Providing and laying in position machine batched and machine mixed design mix M25 grade cement concrete for reinforced cement concrete work, using cement contentas per approved design mix, including pumping of concrete to site of laying butexcluding the cost of centering, shuttering, finishing and reinforcement, includingadmixtures in recommended proportions as per IS: 9103 to accelerate, retard settingof concrete, improve workability without impairing strength and durability as perdirection of Engineer - in-charge. .All work above plinth level upto floor V level |
| 15 | Steel reinforcement for R.C.C work including straightening, cutting, bending, placingin position and binding all complete upto plinth levelThermo - Mechanically Treatedbars of grade Fe-500D or more |
| 16 | Steel reinforcement for R.C.C work including straightening, cutting, bending, placingin position and binding all complete above plinth level.Thermo - MechanicallyTreated bars of grade Fe-500D or more |
| 17 | Reinforced cement concrete work in beams, suspended floors, roofs, having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills,staircases and spiral stair cases up to floor five level excluding the cost of centering,shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (ZoneIII) derived from natural sources: 3 graded stone aggregate 20 mm nominal sizederived from natural sources). |
| 18 | Reinforced cement concrete work in walls (any thickness), including attachedpilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers,abutments, posts and struts etc. up to floor five level excluding cost of centering,shuttering, finishing and reinforcement:1:5:10 ( 1 cement : 5 coarse sand : 10 gradedstone aggregate 40 mm nominal size) |
| 19 | FORM WORK |
| 20 | Centering and shuttering including strutting, etc. and removal of formfor:Foundations, footings, bases of columns, etc for mass concrete |
| 21 | Centering and shuttering including strutting, etc. and removal of form for:Suspendedfloors, roofs, landings, balconies and access platform |
| 22 | Centering and shuttering including strutting, etc. and removal of form for:Walls (anythickness) including attached pilasters, butteresses, plinth and string courses etc. |
| 23 | Centering and shuttering including strutting, etc. and removal of form for:Lintels,beams, plinth beams, girders bressumers and cantilevers |
| 24 | Centering and shuttering including strutting, etc. and removal of form for:Columns,Pillars, Piers, Abutments, Posts and Struts |
| 25 | Centering and shuttering including strutting, etc. and removal of form for:Stairs,(excluding landings ) except spiral - staircases) |
| 26 | Centering and shuttering including strutting, etc. and removal of form for:Edges of slabs and breaks in floors and wallsUnder 20 cm wide |
| 27 | Centering and shuttering including strutting, etc. and removal of form for:Weathershade, Chajjas, corbels etc., including edges |
| 28 | STONE WORKS |
| 29 | Random rubble masonry with hard stone in foundation and plinth including levellingup with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarsesand) |
| 30 | Random rubble masonry with hard stone in superstructure above plinth level and uptofloor five level, including leveling up with cement concrete 1:6:12 (1 cement : 6coarse sand : 12 graded stone aggregate 20 mm nominal size) at window sills, ceilinglevel and the like.Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 31 | MASONRY WORKS |
| 32 | Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x10 cmor nearest available size confirming to IS 2185 part I of 1979 for super structure up tofloor two level for 10 cm thick wall in : CM 1:6 ( 1 cement : 6 coarse sand) includingcost of scaffolding complete |
| 33 | Laterate masonry with neatly dressed laterate stone of size 40x20x15cm or nearestsize in cement mortar 1:6 for super structure above plinth level up to floor two levelincluding all cost of materials, labour charges etc. |
| 34 | Laterate masonry with neatly dressed laterate stone of size 40x20x15cm or nearestsize in cement mortar 1:6 for foundation and basement including all cost of materials,labour charges etc. |
| 35 | PLASTERING |
| 36 | 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) |
| 37 | 6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand) |
| 38 | STEEL WORK |
| 39 | Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes,channels, plates etc., including welding, grinding, buffing, polishing and makingcurvature (wherever required) and fitting the same with necessary stainless steel nutsand bolts complete, i/c fixing the railing with necessary accessories & stainless steeldash fasteners, stainless steel bolts etc., of required size on the top of the floor or theside of waist slab with suitable arrangement as per approval of Engineer-in-charge,(for payment purpose only weight of stainless steel members shall be consideredexcluding fixing accessories such as nuts, bolts, fasteners etc.) |
| 40 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trussesetc., including cutting, hoisting, fixing position and applying a priming coat ofapproved steel primer, including welding and bolted with special shaped washers etc.complete.Hot finished welded type tubes |
| 41 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch ofcorrugation as approved by Engineer-in-charge) 0.50 mm (+0.05%), total coatedthickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade,5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18microns. Sheet should have protective guard film of 25 microns minimum to avoidscratches during transportation and should be supplied in single length upto 12 metreor as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/selftapping screws of size (5.5x55mm) with EPDM seal, complete upto any pitch inhorizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters andtrusses and including cutting to size and shape wherever required. |
| 42 | Structural steel work in single section, fixed with or without connecting plate,including cutting, hoisting, fixing in position and applying a priming coat of approvedsteel primer all complete. |
| 43 | Providing and fixing polycarbonate glass sheet (size, color and design as approved byEngineer-in-charge) 1.5mm. The sheet shall be fixed using self drilling/self tappingscrews of size (5.5x55mm) with EPDM seal, complete upto any pitch in horizontal/vertical or curved surfaces, excluding the cost of purlins, rafters and trusses andincluding cutting to size and shape wherever required. |
| 44 | Providing & fixing on ceiling factory pressedclay decorative floral tile (under mangalore tile roof) of 320mm x 200 mm x 12mmand as per approved pattern on timber frame work complete including extra loweringcharge and scaffolding charges as directed by Engineer-in- Charge.(Timber framework to be paid separately). |
| 45 | DOORS & WINDOWS |
| 46 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I)decorative type, core of block board construction with frame of I st class hard woodand well matched teak 3 ply veneering with vertical grains or cross bands and faceveneers on both faces of shutters.35 mm thick Fixing with hinges of required size andnecessary screws(Note: Hinges and necessary screws hall be paid separately) |
| 47 | Extra for providing ISI marked Stainless Steel butt hinges instead of M.S. pressedbutt hinges bright finished of required size with necessary screws. ( Shutter area to bemeasured) |
| 48 | Providing and fixing aluminium extruded section body tubular type universalhydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body,door weight upto 36 kg to 80 kg and door width form 701 mm to 1000 mm), withdouble speed adjustment with necessary accessories and screws etc. complete. |
| 49 | Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating notless than grade AC 10 as per : 1868), transparent or dyed to required colour or shade,with necessary screws complete:200x10 mm |
| 50 | Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating notless than grade AC 10 as per : 1868), transparent or dyed to required colour or shade with necessary screws complete:100x10 mm |
| 51 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating notless than grade AC 10 as per IS : 1868) transparent or dyed to required colour orshade, with necessary screws etc. complete:125 mm |
| 52 | Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised(anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed torequired colour and shade, with necessary screws etc. complete.Twin rubber stopper |
| 53 | Providing and fixing bright finished 100 mm mortice lock with 6 levers without pairof handles of approved quality for aluminium door, with necessary screws etccomplete as per direction of Engineer- in- charge. |
| 54 | Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of crosssection 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of30 mm thickness. The laminated shall be moulded with fire resistant gradeunsaturated polyester resin and chopped mat. Door frame laminate shall be 2 mmthick and shall be filled with suitable wooden block in all the three legs. The frameshall be covered with fiber glass from all sides. M.S. stay shall be provided at thebottom to steady the frame. |
| 55 | Providing and fixing to existing door frames.30 mm thick Glas Fibre ReinforcedPlastic (FRP) panelled door shutter of required colour and approved brand andmanufacture, made with fire - retardant grade unsaturated polyester resin, moulded to3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame andsuitable blocks of seasoned wood inside at required places for fixing of fittings, castmonolithically with 5 mm thick FRP laminate for panels conforming to IS : 14856,including fixing to frames. |
| 56 | Extra for providing vision panel not exceeding 0.1 sqm in all type of flush doors (costof glass excluded ) (overall area of door shutter to be measured):Rectangular orsquare |
| 57 | 46 mm thick Steel Fire Check Door (Double/Single leaf) of 120 minutes Fire ratingconfirming to BS:476 Part-22 and IS:3614 Part-II. Door shutter are fabricated with 0.8 mm thick galvanized steel sheet pressed formed to provide a 46 mm fully flushdouble skin panel lock with seam joint. The internal construction of panel speciallydesign Honey comb structure with reinforcement at all around. The door frames aremade from 1.2 mm thick galvanized steel sheet pressed form of size 100 mm x 57mm. |
| 58 | Providing wood work in frames of doors, windows, clerestory windows and otherframes, wrought framed and fixed in position with hold fast lugs or with dashfasteners of required dia & length (hold fast lugs or dash fastener shall be paid forseparately), using good quality Anjili wood /jack wood |
| 59 | Providing and fixing glazing in fire resistant door shutters, fixed panels & partitions etc., with G.I. beading made out of 1.6 mm thick G.I. sheet (zinc coating not less than 120 gm/sqm) of size 20 x 33 mm screwed with M4 x 38 mm SS screws at distance 75 mm from the edges and 150 mm c/c , including applying a coat of approved fire resistant primer/powder coating of not less than 30 micron on G.I. beading, & special ceramic tape of 5 x 20 mm size etc complete in all respect as per NBC 2016, IS 16231 (Part 3):2016 and as per direction of Engineer-in-charge with glass of required thickness having 60 minutes of fire resistance both integrity & radiation control (EW60) and minimum 20 minutes of insulation (EI20). The manufacturer have to give test report/certification of fire glass and the glass should have the stamp showing the value of E, EW & EI. The glass shall be tested in approved NABL accredited lab or by any other accreditation body which operates inaccordance with ISO/IEC 17011 and accredits labs as per ISO/IEC 17025 for testing and calibration scopes shall be eligible. The maximum glazing size shall not be more than 1100x2200 mm (w x h) or 2.42 sqm |
| 60 | Providing and fixing 12 mm thick frameless toughened glass door shutter of approvedbrand and manufacture, including providing and fixing top & bottom pivot& double acting hydraulic floor spring type fixing arrangement and makingnecessary holes etc. for fixing required door fittings, all complete as per direction ofEngineer-in-charge ( Door handle, lock and stopper etc to be paid separately) |
| 61 | Providing and fixing of glass door SS Patch Lock with out handle in toughened glassdoor including all necessary screws etc. complete. . |
| 62 | Providing and fixing Steel S.S- 304 (D) Door Pull Both Side Handle of 12 inch, oneSet (2 Handles) ( best make of approved quality ) for Glass, Wooden or similar doorsincluding necessary cutting and making good etc. complete |
| 63 | Providing and fixing 1 mm thick M.S. sheet door with frame of 40x40x6 mm angleiron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittingscomplete, including applying a priming coat of approved steel primer.Using M.S.angels 40x40x6 mm for diagonal braces |
| 64 | ALUMINIUM WORKS |
| 65 | Providing and fixing aluminium work for doors, windows, ventilators and partitionswith extruded built up standard tubular sections/ appropriate Z sections and othersections of approved make conforming to IS : 733 and IS: 1285, fixing with dashfasteners of required dia and size, including necessary filling up the gaps at junctions,i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc.Aluminium sections shall be smooth, rust free, straight, mitred and jointedmechanically wherever required including cleat angle, Aluminnium snap beading forglazing /paneling, C.P. brass/ stainless steel screws, all complete as per architecturaldrawings and the directions of Engineer-in-charge.(Glazing, paneling and dashfasteners to be paid for separately):For fixed portionPowder coated aluminium (minimum thickness of powder coating50 micron) |
| 66 | For shutters of doors, windows & ventilators including providing and fixing hinges /pivots and making provision for fixing of fittings wherever required including thecost of EPDM rubber/ neoprene gasket required (Fittings shall be paid forseparately)Powder coated aluminium (minimum thickness of powder coating 50micron) |
| 67 | Providing and fixing Brass100 mm mortice latch and lock with 6 levers without pairof handles ( best make of approved quality ) for aluminum doors including necessarycutting and making good etc. complete |
| 68 | Providing and fixing 12 mm thick prelaminated particle board flat pressed three layeror graded wood particle board conforming to IS : 12823 Grade I Type II, in panellingfixed in aluminum doors, windows shutters and partition frames with C.P. brass /stainless steel screws etc. complete as per architectural drawings and directions ofEngineer - in- Charge.Pre- laminated particle board with decorative lamination onboth sides |
| 69 | Providing and fixing frosted film in the fixed glass etc. Complete as per the directionof departmental officers |
| 70 | Providing and fixing glazing in door, window, ventilator shutters and partitions etc.with EPDM rubber /neoprene gasket etc. complete as per the architectural drawingsand the directions of engineer-in-charge . (Cost of aluminium snap beading shall bepaid in basic item): toughened glass of 6 mm thickness. |
| 71 | Providing and fixing to existing door frames24 mm thick factory made PVC doorshutters made of styles and rails of a uPVC hollow section of size 59x24 mm and wallthickness 2 mm (± 0.2 mm) with inbuilt edging on both sides. The styles and railsmitred and joint at the corners by means of M.S. galvanised/plastic brackets of size75x220 mm having wall thickness 1.0 mm and stainless steel screws. The styles ofthe shutter reinforced by inserting galvanised M.S. tube of size 20x20 mm and 1 mm(± 0.1 mm) wall thickness. The lock rail made up of 'H' section, a uPVC hollowsection of size 100x24 mm and 2 mm (± 0.2 mm) wall thickness,fixed to the shutterstyles by means of plastic/galvanised M.S. 'U' cleats. The shutter frame filled with auPVC multi-chambered single panel of size not less than 620 mm, having over allthickness of 20 mm and 1 mm (± 0.1 mm) wall thickness. The panels filled verticallyand tie bar at two places by inserting horizontally 6 mm galvanised M.S. rod andfastened with nuts and washers, complete as per manufacturer's specification anddirection of Engineer-in-charge( For W.C. and bathroom door shutter). |
| 72 | Providing and fixing factory made uPVC door frame made of uPVC extrudedsections having an overall dimension as below (tolerance ±1 mm), with wall thickness2.0mm (±0.2 mm), corners of the door frame to be jointed with galvanized bracketsand stainless steel screws, joints mitred and plastic welded. The hinge side vertical ofthe frames reinforced by galvanized M.S. tube of size 19 x 19 mm and 1 mm (± 0.1mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete asper manufacturer's specification and direction of Engineer-in-chargeExtruded sectionprofile size 48x40 mm |
| 73 | Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating notless than grade AC 10 as per : 1868), transparent or dyed to required colour or shade,with necessary screws complete:100x10 mm |
| 74 | Providing and fixing M.S. Grills of required pattern in frames of windows etc. withM.S. flats, square or round bars etc. including priming coat with approved steelprimer all complete.Fixed to openings/ wooden frames with rawl plugs screws etc |
| 75 | Providing and fixing glazing in aluminium door, window, ventilator shutters andpartitions etc. with EPDM rubber / neoprene gasket etc. complete as per thearchitectural drawings and the directions of Engineer - in -Charge. ( Cost ofaluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mmthickness (weight not less than 10kg/sqm) |
| 76 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating notless than grade AC 10 as per IS : 1868) transparent or dyed to required colour orshade, with necessary screws etc. complete:75 mm |
| 77 | TILE WORKS |
| 78 | Chequered terrazo tiles 22 mm thick with graded marble chips of size up to 6 mm infloors, jointed with neat cement slurry mixed with pigment to match the shade of thetiles, including rubbing and polishing complete, on 20 mm thick bed of cement mortar1:4 ( 1 cement : 4 coarse sand):Dark shade pigment using ordinary cement |
| 79 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified bythe manufacturer) with water absorption less than 0.08% and conforming to IS :15622, of approved make, in all colours and shades, laid on 20 mm thick cementmortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cementand matching pigments etc., complete.Size of Tile 600 x 600 mm. |
| 80 | Providing and laying Vitrified tiles indifferent sizes (thickness to be specified bymanufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622,of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thickbed of cement mortar 1:3 (1 cement : 3 coarse sand), including grouting the joint withwhite cement & matching pigments etc. complete.Size of Tile 600x600 mm |
| 81 | Extra for providing opening or required size & shape for wash basin/kitchen sink inkitchen platform, vanity counter and similar location in marble/granite/ stone work,including necessary holes for pillar taps etc. including moulding, rubbing andpolishing of cut edges etc. complete. |
| 82 | Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.Glazed Vitrified tiles Matt/Antiskid finish of size Size of Tile 600 x 600 mm |
| 83 | Providing and applying flooring with white cement/ cement plaster 1:3 (1cement and3 fine sand) 15mm thick in two coats including a flushing coat of cement @ 2.2 kg /SQM)including mixing of approved quality red/ black oxide powder (as permanufactures specification or Engineers direction) .including cost and conveyance ofall materials, labour, curing, etc.as directed by the Engineer-in-charge at all levels. |
| 84 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by themanufacturer), with water absorption less than 0.08% and conforming to IS : 15622,of approved brand & manufacturer,in all colours and shade, in skirting, riser ofsteps, laid with cement based high polymer modified quick set tile adhesive (waterbased) conforming to IS : 15477, in average 6 mm thickness, including grouting ofjoints (Payment for grouting of joints to be made separately).Size of Tile 600x600mm |
| 85 | Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy groutmix 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kgof resin per kg). including filling /grouting and finishing complete as per direction ofEngineer-in-charge.Size of Tile 600x600 mm |
| 86 | Providing and fixing 18 mm thick gang saw cut, mirror, polished, premoulded andprepolished, machine cut for kitchen platforms, vanity counters, window sills, faciasand similar locations, of required size, approved shade, colour and texture laid over20 mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand), joints treated withwhite cement, mixed with matching pigment, epoxy touch ups, including rubbing,curing, moulding and polishing to edges to give high gloss finish etc. complete at alllevels.Area of slab over 0.50 sqm |
| 87 | Providing and fixing stone slab with table rubbed, edges rounded and polished, of size75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase ofappropriate width with chase cutter and embedding the stone in the chase with epoxygrout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stoneaggregate 6 mm nominal size) as per direction of Engineer-in Charge and finished smooth.Granite Stone of approved shade |
| 88 | CUPBOARD WORKS |
| 89 | Providing and fixing Thomson Multi wood board or equivalent make, in shelves withscrews and fittings wherever required, edges to be painted with polyurethane primer(fittings to be paid separately) as per the direction of site Engineer-in-charge. |
| 90 | Providing and fixing concealed hinge of approved quality for 19-20mm thick doorwith stainless steel screws complete : |
| 91 | Providing and fixing special quality bright finished brass cupboard or ward robe lockswith four levers of approved quality including necessary screws etc. complete.40 mm |
| 92 | Providing and fixing magnetic catcher of approved quality in cupboard/ward robeshutters, including fixing with necessary screws etc. complete.Triple strip verticaltype |
| 93 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating notless than grade AC 10 as per IS : 1868) transparent or dyed to required colour orshade, with necessary screws etc. complete:75 mm |
| 94 | providing and fixing powder coated telescopic drawer channels 300 mm long withnecessary screws etc. complete as per directions of Engineer -in-charge. |
| 95 | FALSE CEILING |
| 96 | Providing and fixing false ceiling at all height including providing and fixing of framework made of special sections, power pressed from M.S. sheets and galvanized withzinc coating of 120 gms/ sqm (both side inclusive) as per IS : 277 and consisting ofangle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm, at1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mmdia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangersof 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at thespacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thickbottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm,at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I.intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm longG.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mmhigh having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed towall/partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wallscrews @ 230 mm interval, including fixing of gypsum board to ceiling section andperimeter channel with the help of dry wall screws of size 3.5x25 mm at 230 mm c/c,including jointing and finishing to a flush finish of tapered and square edges of theboard with recommended jointing compound, jointing tapes, finishing with jointingcompound in 3 layers covering upto 150 mm on both sides of joint and two coats ofprimer suitable for board, all as per manufacturer's specification and also includingthe cost of making openings for light fittings, grills, diffusers, cutouts made withframe of perimeter channels suitably fixed, all complete as per drawings, specificationand direction of the Engineer in Charge but excluding the cost of painting with:12.5mm thick tapered edge gypsum moisture resistant board |
| 97 | Providing and fixing tiled false ceiling of approved materials of size 595 x 595 mm intrue horizontal level, suspended on inter locking metal grid of hot dipped galvanizedsteel sections (galvanized @ 120 grams per sqm, both side inclusive) consisting ofmain \\"T\\" runner with suitably spaced joints to get required length and of size 24x38mm made from 0.30 mm thick (minimum) sheet, spaced at 1200mm center to centerand cross \\"T\\" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mmlong spaced between main \\"T\\" at 600 mm center to center to form a grid of 1200x600mm and secondary cross \\"T\\" of length 600 mm and size 24x25 mm made of 0.30 mmthick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to formgrids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceilingtiles of approved texture in the grid including, required cutting/making, opening forservices like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main \\"T\\"runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x 1.6mm fixed to ceiling with 12.5mm dia and 50 mm long dash fasteners, 4 mm GIadjustable rods with galvanised butterfly level clips of size 85x 30x 0.8 mm spaced at1200 mm center to center along main T, bottom exposed width of 24 mm of all Tsections shall be pre-painted with polyester paint, all complete for all heights as perspecifications, drawings and as directed by Engineer -in-charge.12.5 mm thick fullyPerforated Gypsum Board tile made from plaster board having glass fibre conformingto IS: 2095 Part I, of size 595x595 mm, having perforation of 9.7x9.7 mm at 19.4 mmc/c with centre borders of 48 mm and the side borders of 30 mm, backed with nonwoven tissue on the back side , having as NRC ( Noise Reduction Co efficient) of0.79, with 50 mm resin bonded glass wool backing. |
| 98 | CURTAIN WORKS |
| 99 | Providing and fixing horizontal blinds of approved make and model, with 25 mmwide polyester slats, manufactured from 100% high-strength polyester material with suitable stiffness and flexibility, complete with powder-coated headrail and bottomrail, tilt mechanism, lift cords, brackets, end caps, and all necessary operatingaccessories.Slats shall have a polymer/enamel coated finish, UV-resistant, fade-proof, moistureresistant, and suitable for long-term indoor use.Installation shall be carried out complete with all fixtures, fittings, and labour as perthe manufacturer’s specifications and direction of the Engineer-in-Charge.Colour and shade shall be approved by the competent authority. |
| 100 | PAINTING |
| 101 | Providing and applying plaster of paris putty of 2 mm thickness over plastered surfaceto prepare the surface even and smooth complete. |
| 102 | Finishing with Deluxe Multi surface paint system for interiors and exteriors usingprimer as per manufacturers specifications:Two or more coats applied on walls @1.25 ltr/10 sqm over and including one coat of special primer applied @ 0.75 ltr /10sqm |
| 103 | Finishing with Deluxe Multi surface paint system for interiors and exteriors usingprimer as per manufacturers specifications:Painting Steel work with Deluxe MultiSurface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqmover an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand andmanufacture |
| 104 | Providing and applying white cement based putty of average thickness 1 mm, ofapproved brand and manufacturer, over the plastered wall surface to prepare thesurface even and smooth complete. |
| 105 | Melamine polishing of approved brand and manufacture on wood work ( one or morecoat). |
| 106 | Wall painting with acrylic emulsion paint of approved brand and manufacture to givean even shade:Two or more coats on new work |
| 107 | Providing and applying integral crystalline slurry of hydrophilic in nature forwaterproofing treatment to the RCC structures like retaining walls of the basement,water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels/ subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 partsintegral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 partsintegral crystalline slurry : 1 part water) for horizontal surfaces and applying thesame from negative (internal) side with the help of synthetic fiber brush. The materialshall meet the requirements as specified in ACI-212-3R-2010 i.e by reducingpermeability of concrete by more than 90% compared with control concrete as perDIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. Thecrystallineslurry shall be capable of self-healing of cracks up to a width of 0.50mm. The workshall be carried out all complete as per specification and the direction of theengineerincharge. The product performance shall carry guarantee for 10 years against anyleakage.For vertical surface two coats @0.70 kg per sqm |
| 108 | Providing and laying water proofing treatment in sunken portion of WCs, bathroometc., by applying cement slurry mixed with water proofing cement compoundconsisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed withwater proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to aircure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg /sqm mixed withwater proofing cement compound @ 0.126 kg/ sqm. This layer will be allowed to aircure for 4 hours followed with water curing for 48 hours. The rate includespreparation of surface, treatment and sealing of all joints, corners, junctions of pipesand masonry with polymer mixed slurry. |
| 109 | Applying priming coats with primer of approved brand and manufacture, having lowVOC ( Volatile Organic Compound) content.With ready mixed pink or grey primeron wood work (hard and soft wood ) having VOC content less than 50 grams/ litre |
| 110 | PLUMBING AND SANITARY FITTINGS |
| 111 | Providing and fixing white vitreous china pedestal type water closet (European typeW.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, includingflush pipe, with manually controlled device (handle lever), conforming to IS : 7231,with all fittings and fixtures complete, including cutting and making good the wallsand floors wherever required:W.C. pan with ISI marked white solid plastic seat andlid |
| 112 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approvedquality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 113 | Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and112 mm distance from wall of standard shape with bracket of the same materials withsnap fittings of approved quality and colour, weighing not less than 105 gms |
| 114 | Supplying and fixing CP Health Faucet superior quality ( Jagur or equvalent make )including cost of materials and labour charges etc complete as per the direction of siteEngineer-in-charge. |
| 115 | Providing and fixing C.P brass long nose bib cock of approved quality conforming toIS standards and weighing not less than 810 gms.15 mm nominal bore |
| 116 | Providing and fixing C.P. brass long body bib cock of approved quality conforming toIS standards and weighing not less than 690 gms.15 mm nominal bore |
| 117 | Providing and fixing ball valve (brass) of approved quality, High or low pressure,with plastic floats complete:20 mm nominal bore |
| 118 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points ofapproved quality conforming to IS: 893115 mm nominal bore |
| 119 | Providing and fixing PVC pipes includings jointing of pipes with one step PVCsolvent cement, trenching, refilling & testing of Joints complete as per direction ofengineer in charge.110 mm dia 6Kgf/cm2 |
| 120 | Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step PVC solventcement and testing of joints complete as per direction of Engineer-in-Charge 50 mmdia 10Kgf/cm2 - External work - Exposed on wall |
| 121 | Providing and fixing PVC pipes including fixing the pipe with clamps/ clips/ at 1.00m spacing . This includes jointing of pipes with one step PVC solvent cement andtesting of joints complete as per direction of Engineer-in-Charge 110 mm dia 6Kgf/cm2 - External work- Exposed on wall |
| 122 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermalstability for hot & cold water supply, including all CPVC plain & brass threadedfittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing ofpipes& fittings, with one step CPVC solvent cement and the cost of cutting chasesand making good the same including testing of joints complete as per direction ofEngineer-in-Charge. Concealed work, including cutting chases and making good thewall etc.15 mm nominal dia pipes |
| 123 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermalstability for hot & cold water supply, including all CPVC plain & brass threadedfittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing ofpipes& fittings, with one step CPVC solvent cement and the cost of cutting chasesand making good the same including testing of joints complete as per direction ofEngineer-in-Charge. Concealed work, including cutting chases and making good thewall etc.20 mm nominal dia pipes |
| 124 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermalstability for hot & cold water supply, including all CPVC plain & brass threadedfittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing ofpipes& fittings, with one step CPVC solvent cement and the cost of cutting chasesand making good the same including testing of joints complete as per direction ofEngineer-in-Charge. Concealed work, including cutting chases and making good thewall etc.32 mm nominal dia pipes |
| 125 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank:ISI 12701 marked, with cover and suitable locking arrangement and makingnecessary holes for inlet, outlet and overflow pipes but without fittings and the basesupport for tank. |
| 126 | Providing and fixing PTMT extension nipple for water thank pipe, fittings ofapproved quality and colour .20 mm nominal bore, weighing not less than 40 gms |
| 127 | Constructing soak pit 1.20x1.20 m filled with brickbats including S.W. drain pipe 100mm diameter and 1.20 m long complete as per standard design. |
| 128 | Providing and fixing PTMT Bottle Trap for Wash basin and sink.Bottle trap 38 mmsingle piece moulded with height of 270 mm, effective length of tail pipe 260 mmfrom the center of the waste coupling, 77 mm breadth with 25 mm minimum waterseal, weighing not less than 263 gms |
| 129 | Providing and fixing uplasticised PVC connection pipe with brass unions:45 cm length15 mm nominal bore |
| 130 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermalstability for hot & cold water supply, including all CPVC plain & brass threadedfittings including fixing the pipe with clamps at 1.00 m spacing. This includesjointing of pipes & fittings with one step CPVC solvent cement and testing of jointscomplete as per direction of Engineer -in-Charge. Internal work - Exposed on wall15mm nominal dia pipes |
| 131 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermalstability for hot & cold water supply, including all CPVC plain & brass threadedfittings including fixing the pipe with clamps at 1.00 m spacing. This includesjointing of pipes & fittings with one step CPVC solvent cement and testing of jointscomplete as per direction of Engineer -in-Charge. Internal work - Exposed on wall25mm nominal dia pipes |
| 132 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermalstability for hot & cold water supply, including all CPVC plain & brass threadedfittings including fixing the pipe with clamps at 1.00 m spacing. This includesjointing of pipes & fittings with one step CPVC solvent cement and testing of jointscomplete as per direction of Engineer -in-Charge. Internal work - Exposed on wall32mm nominal dia pipes |
| 133 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32mm C.P. brass waste of standard pattern, including painting of fittings and brackets,cutting and making good the walls wherever require:White Vitreous China Surgeontype wash basin of size 660x460 mm with a pair of 15 mm C.P. brass pillar taps withelbow including operated levers |
| 134 | Constructing R.C.C manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand) withR.C.C. top with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix ( 1 cement : 4 coarse sand : 8graded stone aggregate 40 mm nominal size,) inside plastering 12 mm thick withcement mortar 1:3 ( 1 cement : 3 coarse sand) finished with floating coat of neatcement and making channels in cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4graded stone aggregate 20 mm nominal size ) finished with a floating coat of neatcement complete as per standard design:Inside size 120x90 cm and 90 cm deep including C.I. cover with frame ( medium duty) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg( weight of cover 58 kg and weight of frame 58 kg) |
| 135 | Flexible (coil shaped) PVC waste pipe for sink and wash basin 40 mm dia withlength not less than 700 mm i/c PVC waste fittings. |
| 136 | Providing and fixing PVC pipes includings jointing of pipes with one step pvc solventcement, trenching , refilling & testing of joints complete as per direction of Engineerin Charge. 150 mm dia 6 Kgf/cm2 |
| 137 | Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00spacing. This includes jointing of pipes & fittings with one step PVC solvent cementand testing of joints complete as per direction of Engineer-in-Charge Concealedwork, including cutting chases and making good the wall etc. 15 mm pipe 10kgf/cm2 |
| 138 | Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step PVC solventcement and testing of joints complete as per direction of Engineer-in-Charge.Concealed work, including cutting chases and making good the wall etc. 32 mm pipe10Kgf/cm2 |
| 139 | Supplying and placing of 5000 Litre 1mm thick stainless steel water tank of 1750mmdia , 2600mm height, Stainless steel mounted stand around 180kg and grade ofASTM A240 gr.304/ SS316 BA/2B as per the direction of Engineer in-charge. Therate inclusive of all the transportation, Steel stand support, loading and unloadingcharges, fixing charges, Labour charges, etc. Nothing shall be additionally paid in thisitem. |
| 140 | Providing and fixing white vitreous china flat back half stall urinal of size580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) withwaste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P.brass, including painting of fittings and cutting and making good the walls and floorswherever required:Single half stall urinal with 5 litre PVC. automatic flushing cistern |
| 141 | Providing and fixing PVC pipes including fixing the pipe with clamps/ clips/ at 1.00m spacing . This includes jointing of pipes with one step PVC solvent cement andtesting of joints complete as per direction of Engineer-in-Charge 150 mm dia6Kgf/cm2 - External work- Exposed on wall |
| 142 | Providing and fixing white vitreous china laboratory sink including making allconnections excluding cost of fittings:Size 600x450x200 mm |
| 143 | Providing and fixing CP Square gratings complete as per direction of engineer incharge |
| 144 | Providing and fixing CP Waste Coupling for wash basin and sink etc, of approvedbrand, quality and colour. Waste coupling 32mm dia with precisely designed,corrosion resistance and perfect finish. |
| 145 | Providing and fixing up of toilet paper holder with cover lid CP as per the directionsof engineer in the charge. |
| 146 | Supplying and fixing CP Towel rod 60cm or nearest available length including cost ofmaterials and labour charges etc complete as per the direction of site Engineer-incharge |
| 147 | Providing and fixing C.P. brass pillar taps with elbow operated levers ISI marked, 15mm nominal bore. |
| 148 | Supplying and installing ready made PVC Septic tank including the cost of carriage,trenching, placing at the level below ground level as specified as per the direction ofengineer in charge (Provision for CC/RCC/Sand/06mm aggregate for the preparationof bed shall be paid separately)<br> 4. 35 to 50 flush capacity |
| 149 | SIGNAGES |
| 150 | Design, providing and fixing Digital Printed vinyl signage boards with transparent3mm acrylic Sheet with 4 nos. SS Studs with lettering of size 15x45 cm. Complete asper the per the direction of Engineer in charge. <br> |
| 151 | NAME BOARD ACP SHEET WITH MULTIWOOD LETTERING : Design,Supplying andfixing Name Board as per the technical specifications given -1 Inch GI pipe frame(16Guage) for Frame (Sizeproportional), Primer Paint & Black Painted Pipes for Frame.,5mm ACP sheets(Aluminum Composite Panel)for Box area, 18mm thick Multi wood Lettering for Name Board as approvedby<br> Engineer incharge.<br>For Measurement purpose, only area of ACP sheet to be measured |
| 152 | BUILDING PERMIT |
| 153 | Preparation of civil drawings, submission of drawings toLSGD/Municipality/Corporation/ concerned authority and obtaining approval for thesame, complete excluding the Departmental Fee for the Permission and Ownershipetc. Any statutory payment obligation shall be the sole responsibility of the client. |
| 154 | ELECTRICAL WORK |
| 155 | POINT WIRING |
| 156 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group B |
| 157 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C |
| 158 | Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C |
| 159 | Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group B |
| 160 | Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. |
| 161 | Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Independent plug - Short point |
| 162 | SUBMAINS |
| 163 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire |
| 164 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 165 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 166 | PLUG POINTS |
| 167 | Supplying and fixing following modular switch/ socket on the existing modular plate& switch box including connections but excluding modular plate etc. as required.5/6amps switch |
| 168 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet |
| 169 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch |
| 170 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet |
| 171 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 25 amps modular socket outlet and 25 amps modular switch, connection etc. as required for split ac points. |
| 172 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 173 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm) |
| 174 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200mmX75mm) |
| 175 | Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )2 module moulded plastic box on surface |
| 176 | Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )3 module moulded plastic box on surface |
| 177 | Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )6 module moulded plastic box on surface |
| 178 | Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth,metal enclosed plug top along with 20 amps \\"C\\" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required |
| 179 | POWER CIRCUITRY |
| 180 | SMDB (8 WAY) - Supply, installation, Testing and Commissioning of factory fabricated OEM 415 V 50 Hz 4 way complying to IEC 61439 part 1 & 2. The Enclosure shall be IP42 with cable end box, cable alley, pre wire meter chamber with all meters & indicating lamps, Aluminium bus bar, neutral link, DIN bar with all accessories etc, complete with necessary control wiring and protection of control shall be with DIN rail mounted 2A SP MCB. Doors shall be earthed as per prevailing standards. The main earth bus shall be of suitable size copper. All copper joints shall be tinned. Knock outs of proper diameter shall be provided on gland plates. The height of the operating handle of switch gear shall be minimum 300 mm and maximum upto 1800mm from the finished floor level complete as per the directions of engineer in charge. Incomer -1 no. 160 A 36 kA TP MCCB, Outgoing: 2 Nos 80A TP 25 kA MCCB, 1No 63A TP 25 kA MCCB, 1 No 40A TP 25kA MCCB, 2 Nos 32A TP 25kA MCCB, 1 No 25A TP 25 kA MCCB, 1 No. 20A TP 25kA MCCB. |
| 181 | Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+12) - double cover TPN vertical DB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43) |
| 182 | Supply and installation of sheet steel, phosphatised and painted, dust and verminproof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/TP MCB as outgoing (IP 42/43) |
| 183 | Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required8 way (8+24) - three phase double cover (IP 42/43) |
| 184 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 12 way, Double door |
| 185 | Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.160A, 35/36 kA (Ics=100%Icu), 4 pole, current limiting type MCCB with microprocessor based release with overload setting of 50 - 100% having adjustable OL & SC |
| 186 | MCCB AccessoriesSupply and fixing rotary handle, Direct type (including BUC handle with door interlock ) in the existing MCCB of rating up to 250 A |
| 187 | Providing and fixing following rating and breaking capacity MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel. making connections. etc. as required. 100 A, 16KA |
| 188 | Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps |
| 189 | Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker with overcurrent protection (RCBO), having a sensitivity current up to 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 25A, 4P, 30mA |
| 190 | Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current breaker with overload (RCBO), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required up to 25A, 2P, 30mA |
| 191 | Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32amps DP Isolator complete with connections, testing and commissioning etc. as required. |
| 192 | Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Triple pole |
| 193 | Supplying and fixing 40A / 63A, TP MCB, 415 Volts, \\"C\\" curve, miniature circuit breaker in the existing MCB DB complete with connections, testing and commissioning etc as required.(VDB outgoings) |
| 194 | Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole |
| 195 | Supplying and fixing FP CRCA sheet steel enclosure with provision to mount MCB/Isolator/RCCB/RCBO and other modular devices on surface/ recess complete with connections, testing and commissioning etc. as required. |
| 196 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required |
| 197 | CABLE SUPPLY, LAYING AND TERMINATION |
| 198 | Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 120 sq mm |
| 199 | Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).3.5 core 120 sq mm |
| 200 | Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 50 sq mm with factory made clamp |
| 201 | Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm with factory made clamp |
| 202 | Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 10 sq mm with factory made clamp |
| 203 | Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 4 sq mm with factory made clamp |
| 204 | Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armouredaluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3 core 4 sq mm with factory made clamp |
| 205 | Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3 core 6 sq mm with factory made clamp |
| 206 | Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.2 core 4 sq mm with factory made clamp |
| 207 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 120 sq. mm (45mm) |
| 208 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 50 sq. mm (35mm) |
| 209 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm) |
| 210 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm) |
| 211 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 6 sq. mm (22mm) |
| 212 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 4 sq. mm (22mm) |
| 213 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3C X 6 sq. mm (22mm) |
| 214 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 X 4 sq. mm (22mm) |
| 215 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 4 sq. mm (19mm) |
| 216 | CABLE TRAY |
| 217 | Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 150 mm width X 50 mm depth X 1.6 mm thickness |
| 218 | Supplying and installing following size of perforated pre-painted M.S. cable trays bends with perforation not more than 17.5%,, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.150mm width X 50 mm depth X 1.6 mm thickness |
| 219 | Supplying and installing following size of perforated painted with powder coating M.S. cable trays Tee with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 150 mm width X 50 mm depth X 1.6 mm thickness |
| 220 | Supplying and installing following size of perforated painted with powder coating M.S. cable trays Cross Member with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 150 mm width X 50 mm depth X 1.6 mm thickness |
| 221 | Supplying and installing following size of perforated painted with powder coating M.S. cable trays Reducer with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 150 mm width X 50 mm depth X 1.6 mm thickness |
| 222 | Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 100 mm width X 50 mm depth X 1.6 mm thickness |
| 223 | Supplying and installing following size of perforated pre-painted M.S. cable trays bends with perforation not more than 17.5%,, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.100 mm width X 50 mm depth X 1.6 mm thickness |
| 224 | Supplying and installing following size of perforated painted with powder coating M.S. cable trays Tee with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 100 mm width X 50 mm depth X 1.6 mm thickness |
| 225 | Supplying and installing following size of perforated painted with powder coating M.S. cable trays Cross Member with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 100 mm width X 50 mm depth X 1.6 mm thickness |
| 226 | EARTHING PROTECTION |
| 227 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 228 | Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required4.00 mm copper conductor ( 8 SWG) |
| 229 | Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required6.00 mm copper conductor (4 SWG) |
| 230 | Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG) |
| 231 | Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.65 mm copper conductor (12 SWG) |
| 232 | Providing and fixing earth bus of 25 mm X 3 mm copper strip on surface for connections etc. as required. |
| 233 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) |
| 234 | Supply installation, testing and commissioning of following single phase to single phase UPS with battery backup, indoor (IP20) in stand alone configuration, true online double conversion DSP based UPS system, with 30 min backup battery with, input pf>.9, less input current consumption, with input 230V single phase, output 230V single phase , IGBT rectifier and IGBT inverter. It shall be 100% generator compatabile with efficiency > 90% and output power factor > 0.8 and including all accessories etc as required. The UPS system shall be with manual maintenance bypass switch facility. The system shall comply to IEC /EN 62040-1 and relevant IS standard and.The acoustic noise of the system should be less than 58dB. The system shall comply to IEC /EN 62040-1, EN/IEC 62040-2, EN/IEC 62040-3 and relevant IS standard. 2kVA UPS - 1 Nos, Battery Circuit Breaker-1 nos, Battery Required nos. of SMF for providing 30Minutes Backup and Battery Accessories like battery rack, interconnecting cables etc. |
| 235 | FITTINGS |
| 236 | SITC of LED recessed round /square downlight fixture Maximum 18W (+/-2) light fixture. System efficacy >110 lm/W and system lumen output not less than 1980 lm. Luminaire shall have satin finished translucence (HET) diffuser for Uniform illumination and wider light distribution with Die Cast Al powder coated housing, driver with minimum 2.50 KV internal surge protection with electronic drive system, power factor>/=0.95, THD<10%, rated life of 50,000 hours at L70 with a CRI > 80, UGR <19, SDCM<5 and CCT in between 4000K to 5700K. Luminaire shall be flicker free with ripple content is less than 10%, ANSI rated LEDs from reputed makes should be provided and including connection with 1.5 sq.mm FRLSPVC insulated, copper conductor, single core cable and earthing etc. all necessary accessories as required for the light fixture.LM79, LM80, type test certificate & BIS certificate shall be submitted, Luminaire/Drive shall be BIS approved of same |
| 237 | SITC of 4 feet surface/suspended mounted High Efficient LED batten type luminaire with a power consumption of 20 W, luminaire efficacy 100 lm/W with Multistage Isolated Constant Current operated driver with range 150-270V AC. The luminaire shall have sleek design with extruded aluminium section, white CRCA housing with optically efficient poly carbonate diffuser to provide uniform illumination and wider light distribution. The luminaire shall have a CCT of 4000K /6500 K, CRI>80, power factor 0.95, SDCM 5, THD < 20%. The luminaire shall be EMI/ EMC compliant and shall have an internal surge protection of 3 kV with 50,000 burning hours as per L70B50 criteria. In-built electronic driver duly wired up to terminal block.IP20, Temperature range-0 to 50DegC, Driver efficiency>85%, and Safety Extra Low Voltage Safe levelBIS approved and test certificates of LM79 and LM80 reports from NABLaccredited labs. The luminaire shall have flicker content 5% and shall have high and low cut off with auto restart feature, including all accessories necessary as required to complete installation |
| 238 | SITC of 2 feet surface/suspended mounted LED batten type luminaire with a power consumption not more than 10 W, luminaire lumen output of 1100 lumens, luminaire efficacy > 110 lm/W with an operating voltage range from 140 V - 270 V. The luminaire shall have a sleek design with extruded aluminum section, white CRCA housing with optically efficient poly carbonate diffuser to provide uniform illumination and wider light distribution. The luminaire shall have a CCT of 4000K /6500 K, CRI > 80, power factor >0.95, SDCM < 5, THD <10%. The luminaire shall be EMI/ EMC compliant and shall have an internal surge protection of 3 kV with 50,000 burning hours as per L70B50 criteria. The luminaire and driver shall be BIS approved and test certificates of LM79 and LM80 reports from NABL accredited labs. The luminaire shall have flicker content <5% and shall have high and low cut off with auto restart feature, including all accessories necessary as required to complete installation. |
| 239 | SITC of 10 W LED bulkhead luminaire that fits seamlessly in a variety of applications, lumen output greater than 1100 lumens with a system efficacy > 110 lm/W. The luminaire shall have a power factor > 0.9 and shall have 50,000 burning hours as per L70 criteria. The luminaire shall be BIS certified and shall comply all IEC safety requirements and test certificates of LM79 and LM80 reports shall be submitted. The luminaire shall housing shall be made of High Pressure die cast aluminum with a UV stabilized polycarbonate diffuser, IP66 and IK 09 protection, including all accessories necessary as required to complete installation. |
| 240 | Supply Conveyance, installation, testing and commissioning of 36/40W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) |
| 241 | Supplying and fixing of required length 32 mm dia G.I. Pipe (light class) including painting etc. as required. |
| 242 | Supply, installation, testing and commissioning of 1200 mm sweep BEE-5 star rated ceiling fan with brushless direct current motor (BLDC) , class of insulation B , 3 no:s blades , 30 cm long down rod , 2no:s canopies, shackle kit, safety rope , copper winding, power factor not less than .9, service value (CM/M/W) minimum 6.00, Air delivery minimum 210 cum/min,350 RPM (tolerance as per IS :374-2019, THD less than 10% remote or electronic regulator unit for speed control and all remaining accesories including safety pin, nut and bolts , washers, temperature rise equal to 75 deg celsius ( maximum) , insulation resistance more than 2 Megaohm , suitable for 230V,50 Hz, single phase AC supply , earthing etc., complete as required: |
| 243 | SITC of 250mm sweep Exhaust Fan, 900rpm light duty exhaust fan shutter type white colour, or 10 star rated as per BEE, with its all accessories including mounting as required for complete installation |
| 244 | Exhaust Fan Heavy duty : Supply of heavy duty exhaust fan of 450mm sweep in the existing opening, including making good the damage, connection, testing, commissioning etc. as required, including all accessories as required for complete installation including shutter etc. complete as required. |
| 245 | SITC of LED 12W LED Focus light that seamlessly in a variety of applications, consuming a power of 12 W , input Voltage - AC 230V, Beam angle -Adjustable typically 15-45 degree , IP rated Outdoor type, Life span 50,000 Hours, Material Aluminium, weight 0.5-1Kg, The luminaire shall be BIS certified and shall comply all IEC safety requirements and test certificates of LM79 and LM80 reports shall be submitted |
| 246 | SITC of 450mm sweep wall fan having speed control, oscillation control at bottom as suitable for operation on single phase 230 volt AC supply complete with continuous duty motor and all accessories including mounting as required for complete installation. |
| 247 | FAN CLAMP |
| 248 | Providing and fixing M.S. fan clamp type I or II of 16 mm dia M.S. bar, bent to shape with hooked ends in R.C.C. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete. |
| 249 | PUMPS |
| 250 | S & F Motor starters of the following ratingsThree phase DOL starters for 0.25HP to 7.5 HP motor |
| 251 | SITC of 3 HP Pure Copper Winding Domestic/ Industrial Three Phase Self Priming Monoblock Pump Discharge Range minimum 10.7 lps |
| 252 | DOCUMENTATION AND APPROVAL |
| 253 | DOCUMENTATION AND APPROVAL - \\"Charges for Preparation of all drawings submitting and getting approval from KSEB/EI, submitting of Completion certificates and arranging inspection, getting sanction from KSEB/EI, obtaining power allocation if necessary & power connection including CT meter etc. for commissioning of the whole installation in the premises. All statutory payments will be reimbursed on production of the original receipts |
| 254 | NETWORKING |
| 255 | Supply, installation, testing and commissioning of CAT6A Information Outlet, RJ45 with all accessoriesrequired at site to complete the work as per technical specification |
| 256 | SITC OF 2U Rack with PDU unit with Suitable for all type of DVR Box & Double DVR / Network Switch / Server Rack with 4 Power Socket & Cable , Tray (1No) - 1 Cooling Fan Lock & Key. |
| 257 | Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required1 run of Cable |
| 258 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required..Telephone socket outlet |
| 259 | Supply, Installation, Integration and Commissioning of 8 Lines EPABX Intercom System along with krone module as per the direction from Engineer in charge |
| 260 | Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor,unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.1 Pair |
| 261 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm |
| 262 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm |
| 263 | Supply of User Phone- Analog phone |
| 264 | Supply, Installation, Testing & Commissioning of 8 Port Network Switch with 8 No's of 10/100/1000 ports and 2 Gigabit Copper/ SFP Combo ports for uplink |
| 265 | Supply, Installation, Testing and Commissioning of 1.0TR BEE 3 STAR rated INVERTER-Type Air-Cooled Hi-Wall Split-Type Air Conditioners, complete with Indoor Unit (IDU), Outdoor Unit (ODU), surface/concealed copper refrigerant piping with insulation (closed-cell elastomeric nitrile rubber tubular pipe section) up to 3 meters (IDU to ODU), copper power cable up to 3.5 meters (IDU to ODU), including drain pipe, R-32/R-410A/R-407C green refrigerant, wireless remote control, suitable for working between 180–260V with low & high voltage cutoff and 50 Hz, single phase AC supply, capable of performing cooling, dehumidification, and air circulation of the following capacity with scroll/rotary compressor—the system shall be able to deliver 100% of the rated capacity up to 42°C. The unit must be able to operate up to 50°C (outdoor ambient temperature). WARRANTY: The system must include a MINIMUM 5-year Original Equipment Manufacturer (OEM) warranty for PCB, 10-year warranty on compressor, and 1-year warranty for the total machine. Warranty Certificate to be submitted for approval.Approved Make : Hitachi, Daikin, Toshiba, Trane, O-General, Mitsubishi Electric,Voltas, Bluestar, Carrier |
| 266 | Supply, Installation, Testing and Commissioning of 1.5TR BEE 3 STAR rated INVERTER-Type Air-Cooled Hi-Wall Split-Type Air Conditioners, complete with Indoor Unit (IDU), Outdoor Unit (ODU), surface/concealed copper refrigerant piping with insulation (closed-cell elastomeric nitrile rubber tubular pipe section) up to 3 meters (IDU to ODU), copper power cable up to 3.5 meters (IDU to ODU), including drain pipe, R-32/R-410A/R-407C green refrigerant, wireless remote control, suitable for working between 180–260V with low & high voltage cutoff and 50 Hz, single phase AC supply, capable of performing cooling, dehumidification, and air circulation of the following capacity with scroll/rotary compressor—the system shall be able to deliver 100% of the rated capacity up to 42°C. The unit must be able to operate up to 50°C (outdoor ambient temperature). WARRANTY: The system must include a MINIMUM 5-year Original Equipment Manufacturer (OEM) warranty for PCB, 10-year warranty on compressor, and 1-year warranty for the total machine. Warranty Certificate to be submitted for approval. Approved Make : Hitachi, Daikin, Toshiba, Trane, O-General, Mitsubishi Electric, Voltas, Bluestar, Carrier |
| 267 | Supply and installation of automatic voltage STABILIZERS suitable for 1.0TR/1.5TR split AC units, complete with all necessary wiring, connectors, and wall mounting hardware. The stabilizer shall feature intelligent microprocessor-based control with SMT/PTH IC technology, ±1% output voltage accuracy, and startup time delay protection. It shall operate within 170V-270V AC input range (50Hz) with auto-reset low/high voltage cut-off, manual-reset thermal overload protection, short circuit and surge protection |
| 268 | Supply and installation of heavy-duty mild steel (M.S) OUTDOOR STAND for split AC units, comprising of powder-coated mounting brackets with anti-corrosion treatment including all necessary galvanized mounting bolts, nuts, washers, and anchor fasteners. Installation shall be as per manufacturer guidelines and Engineer-in Charge’s directions, ensuring level alignment with wall/floor mounting options |
| 269 | Supply and installation of insulated PVC condensate DRAIN PIPING for split AC units including wall chasing, solvent-welded joints, and complete with clamps at regular intervals. Installation shall be with adequate slope towards drainage point. Work includes all necessary bends, couplings, P-traps and termination into designated drainage system. |
| 270 | Supply and installation of ADDITIONAL REFRIGERANT PIPING KIT for split AC units, comprising of Seamless copper tubing with wall thickness as per AC manufacturer's specifications, flame retardant elastomeric nitrile rubber insulation of minimum 13mm thickness all including necessary power and control cabling. |
| 271 | FIRE FIGHTING |
| 272 | TERRACE PUMP AND AIR VESSEL |
| 273 | (a) Supplying, installation, testing and commissioning of electric driven450lpm at 35m Head |
| 274 | supplying and fixing air vessel made of 250 mm dia 8 mm thick MS sheet , 1200 mm in height with Air release valve on top and flanged connection to riser , drain arrangement with 25 mm dia Gun metal wheel valve with required accessories , pressure guage and painting with synthetic enamel paint of approved shade as required. |
| 275 | Power Control Panel- Supply, Installation, testing and commissioning of combined type automatic motor control panel with necessary star delta starters, indication lamps etc. for terrace fire pumps |
| 276 | PIPE AND ACCESSORIES |
| 277 | Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. a) 20 mm nominal Internal dia water hose thermoplastic(Textile reinforced) type-2 as per IS:12585 b) 20 mm nominal internal dia gun metal globe valve &nozzle c) Drum and brackets for fixing the equipments on wall. d) Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket. 30 m |
| 278 | Providing, laying, testing and commissioning of C class heavy duty M S Pipe conforming to IS 3589,IS 1239 i/c welding ,fittings, like elbows, tees, flanges, tapers, nuts ,bolts ,gaskets etc., and fixing the pipe on the wall , ceiling with suitable clamp or support frame and painting with two or more coats of synthetic enamel paints of required shades complete as required:50 mm dia |
| 279 | Providing, laying, testing and commissioning of C class heavy duty M S Pipe conforming to IS 3589,IS 1239 i/c welding ,fittings, like elbows, tees, flanges, tapers, nuts ,bolts ,gaskets etc., and fixing the pipe on the wall , ceiling with suitable clamp or support frame and painting with two or more coats of synthetic enamel paints of required shades complete as required:100mm dia |
| 280 | VALVES ,SWITCHES AND GAUGES |
| 281 | Supplying, fixing, testing and commissioning of Butterfly Valve of PN 1.6 rating with bronze or gun metal seat duly ISI marked complete with nuts, bolts ,washers ,gaskets conforming to IS 13095 of following sizes as required:100 mm dia |
| 282 | Providing,installation,testing and commissioning of non-return valve of following sizes conforming to IS :5312 complete with rubber gasket, GI bolts , nuts, washers etc as required.100 mm dia |
| 283 | Providing and fixing in position the industrial type pressure gauges with gun metal / brass valves complete as required |
| 284 | Providing, installation ,testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel , Grade 304,sheet with3 mm dia holes with stainless steel flange.100 mm dia |
| 285 | Providing and fixing of pressure switch in MS pipeline including connection etc as required: |
| 286 | Providing and fixing of flow switch in MS pipe including connection etc as required:100 mm dia |
| 287 | FIRE EXTINGUISHERS |
| 288 | Supplying, installing and commissioning Portable Fire extinguishers of following type & capacity.Co2 type Fire Extinguisher, made from brand new seamless Steel cylinder, as per IS: 7285 and CCE approval, fitted with Discharge hose and horn and Wheel type valve with initial Charge and mounted on Rubber Wheels / wall mounted brackets as per IS: 16018 specification, bearing ISI Mark. 4.5 Kgs |
| 289 | Supplying, installing and commissioning Portable Fire extinguishers of following type & capacity -ABC powder type fire extinguisher with initial filling in brand new cylinder with powder coated finish, fitted with Gun metal union, high pressure CO2 gas cartridge, discharge hose, wall mounting bracket etc.complete, confirming to IS:15683 : 6 Kgs |
| 290 | AUTHORITY APPROVAL AND SIGNAGES |
| 291 | AUTHORITY APPROVALS AND COORDINATION: Preparation of all drawings, submitting and getting approval from fire department, submitting of completion certificates and arranging inspection, getting sanction, etc. for commissioning of the whole installation in the premises.(All statutory payments will be reimbursed with original receipts.) |
| 292 | SITC of self glowing \\"FIRE EXITINGUISHER\\" sign boards of size (150 X 150 mm) in triangular shape fixed on the wall and shall be as per IS code 9457:2005, IS 12349, IS 12407. |
| 293 | Supply, installation, testing and commissioning of Fire Exit Light, Laser type, with High Glow LED, size:300x 178 x 32 mm. or 390 x190 x 60mm, Ceiling Mounting type with hanging clamps, on/off switch, Red /Green Colour option with minimum of 25 Mtr. viewing distance, power consumption: 5.0 Watt per face (maximum) Double Side Display and shall be as per IS code 9457:2005, IS 12349, IS 12407. |
| 294 | Supply, installation, testing and commissioning of Fire Exit Light, Laser type, with High Glow LED, size:300x 178 x 32 mm. or 390 x190 x 60mm, Ceiling Mountingtype with hanging clamps, on/off switch, Red /Green Colour option with minimum of 25 Mtr. viewing distance, power consumption: 5.0 Watt per face (maximum), with Single Side Display and shall be as per IS code 9457:2005, IS 12349, IS 12407. |
| 295 | Providing and fixing in position the signage \\" FIRE ORDER\\" on 3mm thick \\"Opaque\\" PVC foam board of computerized cut, PVC non reflective self adhesive vinyl painted foam board of 2' x 3' and shall be as per IS code 9457:2005, IS 12349, IS 12407 |
| 296 | Providing and fixing of Floor Identification Signage (MAIN STAIRCASE, FIRE STAIRCASE, FIRE ASSEMBLY POINT, PUMP ROOM, FIRE CONTROL ROOM, ELECTRICAL ROOM, FIRE LIFT, PASSENGER LIFT Etc.) on every floor, lettering size shall be 5 Cm. with contrasting colour from background. Size shall be 15cm x 30cm and shall be as per IS code 9457:2005, IS 12349, IS 1240 |
| 297 | Providing and fixing of Floor identification signage (e.g., GROUND FLOOR, FIRST FLOOR, etc.) will be placed at each stair enclosure on every floor, displaying the floor number in words. The letter size will be 5 cm, with a contrasting color to the background. The dimensions of the signage will be 15 cm x 30 cm, and it will comply IS Code 9457:2005, IS 12349, and IS 12407. |
| 298 | Providing and fixing of signage : \\"IN CASE OF FIRE, USE STAIRS UNLESS INSTRUCTED OTHERWISE\\" with red letters, each 1.25 cm in height, on a white background. The board dimensions will be 25 cm x 30 cm and will be mounted at a height of 2 meters from the finished floor, positioned near manual call points. The signage will comply with IS Code 9457:2005, IS 12349, and IS 1240 standards. |
| 299 | FIRE BRIGADE |
| 300 | FIRE BRIGADE INLET : Supply, installation, testing and commissioning of 3 way tank filling Inlet connection of 63 mm dia. valves instantaneous coupling type arrangement to be connected to wet riser main. |
| 301 | FIRE ALARM SYSTEM |
| 302 | FIRE DETECTION AND ALARM SYSTEM (CONVENTIONAL)Supplying,installation, testing & commissioning of manual call boxes of MS Construction in surface/recess with stainless steel chain & hammer assembly Complete with glass and push button etc. as required. |
| 303 | FIRE DETECTION AND ALARM SYSTEM (CONVENTIONAL)Supplying, installation, testing & commissioning fire alarm sounder with facility to make announcement, mounted in M.S. box (16 SWG) with hinged cover plate & suitable for operation with amplifier i/c line matching transformer etc. complete as required |
| 304 | Supplying, installation, testing & commissioning sector panel suitable for following zones, complete with visual indications for short circuit fault, open circuit fault, fire condition and all other standard facilities as per IS:2189 with mimic diagram for all area/zone covered, complete with all connections, interconnections as required.4 Zone |
| 305 | CABLING & WIRINGSupplying & laying of 2x1.5 sq mm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required. |
| 306 | LPG PIPING |
| 307 | Supply and installation of copper pipe C12200 - (DHP) High Phosphorus Deoxidized Tough Pitch Copper pipe with an outer diameter (OD) of 3/8 inches and a 14 SWG (Standard Wire Gauge), featuring a red or yellow sleeve. The main pipeline should be concealed before proceeding. It must be properly welded or connected with a minimum brass joint. Perform a leakage test at 50 PSI to 100 psi for 24 hours.\\" concealed with GI round pipe or hard PVC casing cap. The pipe should be laid within the wall, supported by suitable SS (stainless steel) or MS (mild steel) clamps, spaced at intervals of 1 meter. Ensure proper support is provided in all necessary areas. |
| 308 | Supply and installation of copper pipe C12200 - (DHP) High Phosphorus Deoxidized Tough Pitch Copper pipe with an outer diameter (OD) of 5/8 inches and a 14 SWG (Standard Wire Gauge), featuring a red or yellow sleeve. The main pipeline should be concealed before proceeding. It must be properly welded or connected with a minimum brass joint. Perform a leakage test at 50 PSI to 100 psi for 24 hours.\\" concealed with GI round pipe or hard PVC casing cap. The pipe should be laid within the wall, supported by suitable SS (stainless steel) or MS (mild steel) clamps, spaced at intervals of 1 meter. Ensure proper support is provided in all necessary areas. |
| 309 | ASSOCIATED WORKS |
| 310 | Supply and installation of 5+5 LPG manifold of Stainless Steel and brass suitable for connecting 10nos of LPG cylinders to the manifold header or distribution system with inlet pressure 18 bar to 20 bar with 5 cylinder on working and other 5 cylinder by stand optional. LPG Cylinder Adapter click ON press fit type of Self closing valves as per IS:8737 are having outlet to connect threaded fittings of regulator/pigtails to these valves. The click adaptors are to be fitted on the valve which makes leak proof coupling between valve outlet. LPG Suraksha hose pipe ISImark- commercial with brass fittings on both end approximately 1 to 1.5 mtr length should be connected from manifold to the each gas cylinders. LPG Gas Regulator suitable for reducing pressure of 1 - 17 Kg/cm² to 0.5 - 4 Kg/cm should be provided. Each cylinder connected with brass NRV and output connection of brass 5/8 with suitable valve for emergency open and close and 4 inch gauge of 0 to100Mbar as per the direction of Engineer in charge |
| 311 | 5/8 inch line valve with fiitings (LPG) - SITC of 5/8 inch line valves for use in lpg manifold rooms and to facilitate the isolation of areas or areas where area zone valve are unnecessary. These shall be of the ball valve type and shall be constructed of a nickel plated brass body, PTFE seats and brass chrome plated ball. The valve shall be operated by a manual operating lever by 90º turn. All lpg gas line ball valves shall provide a full bore flow and shall be cleaned for oxygen service and fully tested. The valve assembly shall terminate in copper stub pipes to enable brazing directly into the distribution system using the flux less brazing technique. A locking device shall be provided to lock the valve in either the fully open or fully closed position. Line valves shall be located in readily accessible areas of ducts and shafts, however care should to ensure safety to prevent danger from leakage. |
| 312 | 3/8 inch line valve with fittings (LPG) - SITC of 3/8 inch line valves for use in lpg manifold rooms and to facilitate the isolation of areas or areas where area zone valve are unnecessary. These shall be of the ball valve type and shall be constructed of a nickel plated brass body, PTFE seats and brass chrome plated ball. The valve shall be operated by a manual operating lever by 90º turn. All lpg gas line ball valves shall provide a full bore flow and shall be cleaned for oxygen service and fully tested. The valve assembly shall terminate in copper stub pipes to enable brazing directly into the distribution system using the flux less brazing technique. A locking device shall be provided to lock the valve in either the fully open or fully closed position. Line valves shall be located in readily accessible areas of ducts and shafts, however care should to ensure safety to prevent danger from leakage. |
| 313 | Supply, installation, testing and commissioning of burner control valve with required fittings at suitable burners for control the intensity of flame and shutdown of the particular area during maintenance as per the direction of Engineer in charge. |
| 314 | Supply, installation, testing and commissioning of Burner of SS heavy duty 18 inch with all fittings, tail pipe with connector and Burner Gas Stove made of SS304 size 30x30x 16, suitable for 40mm diameter boiler vessels, SS 304 stand. Each burner should flow control valve |
| 315 | Supply, installation, testing and commissioning of LPG consumption meter in suitable areas as per the direction of Engineer in charge. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail