| 1 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. |
| 2 | Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. |
| 3 | 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 4 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 5 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland / Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Concrete of M25 grade with minimum cement content of 330 kg /cum Lintel Work |
| 6 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland / Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. All works above plinth level upto floor V level Slab Work |
| 7 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland / Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete All works above plinth level upto floor V level.Plinth Beam |
| 8 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland / Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. All works up to plinth level Footing |
| 9 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland / Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. All works above plinth level upto floor V level Column |
| 10 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 11 | Mild steel or iron work in heavy sizes such as trusses built up gates doors frames records racks roof woork gates etc.wrought to required form including drilling holes rivetting or welding where necessary and also including supply of steel bolts nut wastage etc.and their fixing requiredfor proper completion of the qwork in new item. |
| 12 | Supply of ms grill of a approved quality and dwawing made of flat iron bigger then 20x40mm size including supply of all materials; fabrication, labour ,T&P and all taxes and also one coat red oxide paint complete in all respect as per direction of Engineer -in- charge for proper completion of work at site. |
| 13 | 12mm Cement plaster of mix 1:6 ( 1cement: 6 coarse sand ) |
| 14 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete. |
| 15 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade :. New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20kg/ 10 sqm) |
| 16 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture |
| 17 | Providing and laying ''brick bat coba'' 100 mm thick laid with M-15 Class brick bat coba 7.5 cm thick with gap of 1 mm to each other ,over 20 mm thick base of cement morter 1:4 cement and coarse sand mixed with water proofing compound spreading cement slurry mixed with aerelic cement concrete water proffing compound .filled gaps of coba &top of coba morter mixed with water proofing compound in 1:4 cement and coarse sand morter finished smooth & top mashed false square 30cm x30cm and side wall parapet shal be monotythic plaster wall upto 30 cm figher and junction and corner shall rounded by brick ballast cement and coarse sand and masonry coba with top finishing plaster mixing with acetic water proofing compound @ 2% by weight & including supply of all materials labour T&P etc. required for proper completion of work ,Chapt-11 New item. |
| 18 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 19 | Providing & fixing Stainless steel sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 250mm x 16mm . |
| 20 | Providing and fixing 150 mm bright finished floor brass door stopper with rubber cushion, necessary brass screws etc. to suit shutter thickness complete. |
| 21 | Providing and fixing Gl Clip in Metal Ceiling System of 600x600 mm module which includes providing and fixing 'C' wall angle of size 20x30x20 mm made of 0.5 mm thick pre painted steel along the perimeter of the room with help of nylon sleeves and wooden screws at 300 mm center to centre, suspending the main C carrier of size 10x38x10 mm made of G.I steel 0.7 mm thick from the soffit with help of soffit cleat 37x27x25x1.6 mm, rawl plugs of size 38x12 mm and C carrier suspension clip and main carrier bracket at 1000 mm c/c. Inverted triangle shaped Spring Tee having height of 24 mm and width of 34 mm made of Gl steel 0.45 mm thick is then fixed to the main C carrier and in direction perpendicular to it at 600 mm centers with help of suspension brackets. Wherever the main C carrier and spring T have to join, C carrier and spring T connectors have to be used. All sections to be galvanized @ 120 gms/sqm (both side inclusive), fixing with clip in tiles into spring T with : GI Metal Ceiling Clip in plain Beveled edge global white color tiles of size 600x600 and 0.5 mm thick with 25 mm height, made of G I sheet having galvanizing of 100 gms/ sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation. |
| 22 | Providing and fixing factory made uPVC glazed/wire mesh windows/ doors comprising of lead free uPVC multi-chambered frame, sash and mullion/coupler (where ever required) extruded profiles having minimum wall thickness of 1.70 mm for Series R1 and R2 profiles and 2.10 mm for Series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and design duly reinforced with galvanized mild steel section made of required shape & size as per CPWD Specification, uPVC extruded glazing beads, interlocks and Inline sash adaptor (where ever required) of appropriate dimension, EPDM gasket, hardware, SS 304 grade fasteners of minimum 8 mm dia with countersunk head, comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as per IS 1367: Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc.After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of approved size and quality, all complete as per approved drawing conforming to CPWD specification & direction of Engineer-in-Charge. Section of steel reinforcement and cross sections of uPVC profiles to be as per design approved by Engineer-in-Charge.Using R4 series with frame (115 mm & above)x (45 mm & above) & both glazed and fly screen sash (44 mm & above) x (55 mm & above) with zinc alloy (zamak) powder coated handle on every glazed panel along with multi- point locking system. (Height above 1.8m) |
| 23 | Supply and fixing 100 mm dia PVC pipe ,rain water pipes including supply of all material labour T&P etc. required for proper completion of the work (as per analysis rate) |
| 24 | Supply and fixing 100 mm dia PVC Bend or Tee including supply of all material labour T&P etc. required for proper completion of the work .as per direction of Engineer-in- Charge.Material Extra item Si No- 36(34) |
| 25 | Supply and fixing of a Dios/Podium including loading and unloading with cartage as per mafket rate |
| 26 | Supply and fixing of Smart Digital Board including loading and unloading with cartage as per mafket rate with mice and sound |
| 27 | Supply and fixing of Hitachi 1.5 ton AC including loading and unloading with cartage as per mafket rate |
| 28 | Supply and fixing Microtek Stabilizer including loading and unloading with cartage as per mafket rate |
| 29 | Supply and fixing Havells Water Purifier including loading and unloading with cartage as per mafket rate |
| 30 | Supply and fixing Exide Battery including loading and unloading with cartage as per mafket rate |
| 31 | Supply and fixing Microtek Inverter 24 volt including loading and unloading with cartage as per mafket rate |
| 32 | S/F Teaching Plateform |
| 33 | Wiring of 2 no of 4 sq mm |
| 34 | Wiring of 2 no of 2.5 sq mm |
| 35 | Wiring of 2 no of 1.5 sq mm |
| 36 | Wiring pont of light in 1.5 sqm mm FRLSH PVC |
| 37 | Ceilling Fan |
| 38 | power point for ac |
| 39 | PANNEL LIGHT |
| 40 | PANNEL LIGHT |
| 41 | SWITCH BOARD 18 module |
| 42 | SWITCH BOARD 6 module |
| 43 | 6 Amp Switch |
| 44 | power point for ac |
| 45 | Socket 6 Amp |
| 46 | Socket 15amp |
| 47 | Switch 15 amp |
| 48 | Fan Regulator |
| 49 | indecator |
| 50 | AC POINT |
| 51 | Wall Mounted Street Light |
| 52 | MCB 25Amp,16 Amp,10 Amp, 6Amp with iculator and Box |
| 53 | Earthing proper Connection Please Enable Macros to View BoQ information |