| 1 | Dismantling plain or corrugated steel sheeting any gauge, thickness complete all as specified and directed. |
| 2 | S&F for mild steel rolled sections FE-410-W Gde E-250 quality 'A' as in main and cross beams, hip and jack rafters, purlins where connected to common rafters and running rails for gusset plates,, valley gutter and trusses etc, fixed with angle cleats or other connecting plates and hanging also fastening and fixing including dismantling old , complete all as specified and directed. |
| 3 | S&F 0.63mm thick galvanised, corrugated mild steel sheeting with two corrugations side lap, fixed with coach screws, and washer, in roofs wall etc with grade of zinc coating 120 GSM fixed with self tapping screws complete all as specified and directed. |
| 4 | All as per item No. 3 here-in-before but except sheets re-use sheets retrieved from Item no 01 above . (Note : the rates are deemed to be included for shifting & transportation of sheets from one location to other location at any distance) |
| 5 | S&F 2mm thick Fibre glass reinforced translucent corrugated sheeting with two corrugation side laps fixed with self tapping screws, including dismantling the existing sheet and removing the debris outside the defence land complete all as specified and directed. |
| 6 | S&F 2mm thick Fibre glass reinforced translucent Trapizoidal profile sheet as per site requirement fixed with self tapping screws, including dismantling the existing sheet, complete all as specified and directed. |
| 7 | S&F 0.63 mm thick plain, black ,mild steel sheeting in ridges hips, valley gutters, drip and straight flashings (length and girth as fixed), fixed with self tapping screws, complete all as specified and directed. |
| 8 | S&F for 2mm thick plain, black , mild steel sheeting in ridges hips, valley gutters, tank for rain water collection with hole for fitting of 200 mm Pvc pipe and welded or soldered joints are provided complete all as specified and directed. |
| 9 | Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan necks etc (measured overall as fixed along the centre line over fittings and accessories) complete and directed. |
| 10 | S&F for 200mm bore PVC (SWR) pipes double socketed in any length with rubber ring joints fixed to walls including stack clamp to fix Rain water pipe with wall( As per site requirement) complete all as specified and as directed. |
| 11 | S&F for 200mm bore PVC (SWR) bends of any radius, complete all as specified and directed. |
| 12 | Material and labour for PCC 1:2:4 type B-2 using 40mm graded Crushed stone aggregate as in foundation filling and mass concrete all as specified and directed. |
| 13 | S&F for prepainted galvalume aluminium zinc coating GI base wave type coloured steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa (AZ -150) as in roof covering / cladding to wall, fixed with self tapping screws as specified. Make : TATA BLUESCOPE INDUSTRIES Ltd /JSW Steel /BHUSAN Steel Ltd |
| 14 | S&F for pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall/ valley gutters, etc fixed with self tapping screws as specified. |
| 15 | Material and labour for applying two coats of synthetic enamel paint (in camouflage pattern using number of colours) over and including a coat of red oxide primer, on new steel surfaces over 10cm width or girth, including preparation of steel surface, complete all as specified and directed. |
| 16 | M&L for applying one coat of synthetic enamel paint on old steel surfaces over 10cm width or girth, including preparation of old painted surfaces as per existing pattern/camouflage complete all as specified and directed. |
| 17 | Hacking out old broken glass (any thickness, size quality or description) from wooden frames, metal frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads complete all as specified. |
| 18 | S&F for rough cast, wired glass 6.4mm thick and glazing with putty/beads (any type as per site requirement) in square exceeding 0.5 Sqm but not exceeding 0.75 Sqm in each pane complete all as specified and directed. |
| 19 | S&F for rough cast, wired glass 6.4mm thick and glazing with putty/beads (any type as per site requirement) in square exceeding 0.75 Sqm but not exceeding 1.0 Sqm in each pane complete all as specified and directed. |
| 20 | S&F for rough cast, wired glass 6.4mm thick and glazing with putty/beads (any type as site required) in square exceeding 1.0 Sqm but not exceeding 1.5 Sqm in each pane complete all as specified and directed. |
| 21 | M&L for 6mm Epoxy PU flooring complete all as specified and directed and as per manufacturer's instruction consisting of the following steps/stage.(a) Surface cleaning : Cleaning of surface free from dust, dirt, moisture & foreign material from the floor by grinding and scrubbing.(b) M & L for Epoxy polyurethane floor coating of 200 micron thick priming coat 3800 microns screed coat and 2000 micron thick top coat including necessary prepartion of the existing surface all as per manufacturer's instructions complete all as specified and directed.(c) Forming joints 8 mm to 40mm average width and 20mm average deep with closed cell poyethylene back rod of required dia more than width of joint and top 12mm depth primed and sealed with polyurethane based sealing compound including applying masking tap on edge of joints to prevent accidental spillage including cutting the masking tape by mechanical means after application of sealant including cutting out the existing joint up to the required width /depth using diamod cutter, removing the debris and other foreign material to out side from defence land complete all as specified and dirtected. |
| 22 | S&F in repair Nylon bird proofing poly raisin net (approx) 1.00 mm dia and (approx) 25X25 mm mesh size of square or diamond type, twin breaking strength 21 kgf min, mesh breaking strenth 17 kgf min, knot breaking strength 27 kgf min, including scaffolding for fixing with truss, purlins by binding with nylon wire of same quality and same dia etc. proper tightening in straight, levelled at any height up to 25 m of hangers, complete all as specified and directed by Engineer-in- charge.Note:- Testing of material shall be carried out as per IS: 5812 (part-4) : 1993 & ISO 1805: 1973 The cost of which shall be deemed to be included in the rate quoted. |
| 23 | M&L for painting lines and dashes etc on PU Flooring by applying two coats of PU floor marking paint white/black/yellow/orange or any other colours and 20cm/25cm/30cm wide strips on PU Flooring surface by using mechanical PU floor marking machine like cold spray(Airless/Pneumatic)/Electrostatic cold-painting machine or equivalent approved including complete scrapping of old treatment/existing PU Paint layers and complete removal of dust particles by brushes or sweeping with brooms complete all as specified directed by Engr- in- charge .Note : Colour should be approved by GE. |
| 24 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), and rubbish off the premises complete all as specified and directed. |
| 25 | M&L for vitrified tiles light shade 8 to10mm thick (square/rectangular) polished area of each tile 600mm x 600mm / 605mm x 605mm over and including 15mm thick Screed bed or bedding layer in CM 1:6 for laying floor finishes, set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed. |
| 26 | All as per item Ser No 25 here-in-before but in skirting and dado laid over and including 10mm thick rendering in CM 1:4 and pointing complete all as specified and as directed. |
| 27 | Taking down cement plaster on brick/concrete walls etc and racking out joints, hacking for key, scrubbing down with water etc any description complete all as specified and directed by Engr-in-Charge. |
| 28 | M&L for 10mm thick plaster in CM 1:6 on fair face of concrete surface or brick walls finished even and smooth without using extra cement complete all as specified |
| 29 | M&L for 15mm thick plaster in CM 1:4 on other than fair face of brick walls or concrete surface, finished the surface even and smooth without using extra cement complete all as specified |
| 30 | M&L for preparing newly plastered wall surface and applying two or more coats of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/10 Sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 Sqm at any height including necessary scaffolding etc complete all as specified by Engr-in-Charge. |
| 31 | M&L for preparation of newly plastered surface of wall and applying two coats of oil bound distemper over a coat of average 1mm thick wall care putty to make the surface smooth at any height including necessary scaffolding etc complete all as specified by Engr-in-Charge. |
| 32 | M&L for for preparation of old plastered/unplastered/ concrete surfaces of walls and applying two coats of exterior emulsion paint (in camouflage pattern using number of colours) over and including one coat of primer and at any height including necessary scaffolding etc complete all as specified.Note : Pattern of camouflage shall be approved by GE. |
| 33 | M&L for Running welding in repairs thickness of metal to be welded exc 6mm and not exceeding 9 mm all as specified and as directed. |
| 34 | M&L for Running welding in repairs length not exceeding 2.5cm and thickness of metal to be welded exc 6mm and not exceeding 9 mm all as specified and as directed. |
| 35 | M&L for Running welding in repairs length exceeding 2.5cm but not exceeding 5 Cm , thickness of metal to be welded exc 6mm and not exceeding 9 mm all as specified and as directed. |
| 36 | M&L for greassing all moving parts of rolling shutters gear operated rolling shutters exc 8 sqm but not exc 16 sqm of clear opening including hood cover refixing the same and including replacement of gear box assemblyand replacement of mild steel spring, ball bearing etc all as specified by Engr in Charge. |
| 37 | S&F in repairs/replacement of laths/strips of rolling shutters made of 1.25mm thick MS Sheet for shutters upto 4 metre width including red oxide primer and two coat of synthetic enamel paint complete all as specified by Engr in Charge. |
| 38 | S&F in repairs 20mm wide door seal aluminium powder coated fixed with screws on bottom rails of door shutters complete all as specified. |
| 39 | Easing of aluminium windows/door shutters for closing /opening, including tightening of hinges, adjustment of floor door closer, sliding bolts with new screws etc, adjustment of handles, other miscellaneous adjustments complete all as specified. |
| 40 | Material and labour for chequered cement concrete tiles 250 mm x 250 mm x 25 mm thick, set, jointed and pointed in neat cement slurry with grey cement and colour pigment in floor including dismantling and removing the debris outside the defence land all as specified. |
| 41 | Material and labour for screed bed or bedding layers of 15 mm thick cement mortar (1:6) for laying floor finishes all as specified. |
| 42 | Dismantling of Stone slabs and tiles of any description or thickness in floors, aprons etc laid dry or laid dry and pointed. |
| 43 | M&L for MAchine pressed coloured precast concrete interlocking paver blocks with grey cement and pigment any shape and size, shade as approved by GE, 80mm thick conforming to IS 15658-2006 M-40 grade complete all as specified and as directed. Make : Sandeep Bros/ NTC/ ULTRA |
| 44 | M&L for Sand filling under floors or in foundations including watering and consolidation complete all as specified and as directed. Please Enable Macros to View BoQ information |
| 45 | M&L for Sand filling under floors or in foundations including watering and consolidation complete all as specified and as directed. Please Enable Macros to View BoQ information |