| 1 | Demolition of cement concrete of any description and in any position not otherwise specifically provided for (such as copings, bands of any type, roof padding, kerbs, sunken etc; overall thickness and removing the dust debris etc to a distance not exc 250 meter from site and disposing the same complete all as specified and as directed by Engineer in charge. |
| 2 | Taking down cement plaster, on brick or stone walls etc, including raking out joints, hacking for key, scrubbing down with water etc incl disposal of debris complete all as specified and as directed |
| 3 | Taking down chowkhats or frames with shutters (without taking off shutters from the frames) exc 1.5 sqm but n.exc 4.00 Sqm each and removing from site or to store as directed by Engineer incharge. |
| 4 | Taking down chowkhats or frames with shutters (without taking off shutters from the frames) not exc 1.5 sqm each and removing from site or to store as directed by Engineer incharge. |
| 5 | Taking down shutters any description exc 1.00 sqm but not exc 2.00 Sqm each complete as directed by Engineer in charge. |
| 6 | Taking down shutters any description exc 1.00 sqm but not exc 2.00 Sqm each and refixing the shutter in same opening after easing and adjusting complete as directed by Engineer in charge. |
| 7 | Demolition of brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars,etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified. |
| 8 | M&L Pre-cast cement concrete type C-1 using (20mm graded stone aggregate with block masonry with solid blocks, exc.10 cm in width in set in cement mortar 1:6 complete all as specified. |
| 9 | Dismantling Stone slabs in roofs, suspended floors, chajjas, landings, etc., any thickness, jointed in any mortar complete all as specified. |
| 10 | M&L Jodhpur stone roof slabs, self faced exceeding 10cm but not exceeding 12.5 cm thick, 25cm to 35cm wide, hoisted and set, jointed and grouted in cement mortar 1:3, complete all as specified and as directed. |
| 11 | -ditto- all as per above item but, except stone complete all as specified and as directed. |
| 12 | M&L for rendering 15 mm thick in CM 1:4 using 100% coarse sand on roof surface with Liquid water proofing compound as per manufacturer's instruction inclu provided as floating / setting coat of cement complete all as specified and directed. Note : The plaster shall be provided when the concrete is green and plaster surfaces shall be steel toweled to get a smooth surface usining extra cement. Water proofing compound shall be measured and paid separately under respective item |
| 13 | M&L providing and applying roof treatment as following stage:-(i) Apply 1st coat of PU coating ( Shaliurethane LHM @ 650gm/Sqm or equivalent by brush/roller/spray. Spread non-woven geo-textile or glass fiber tissue of 45 GDM with overlaps of 50 mm in both directions when the surface is still tacky, this is optional,to be assessed as per site requirements to achieve higher mechanical properties.(ii) Allow 1st coat to dry for 10-12 Hrs.(iii) (Apply 2nd coat of PU membrane (ShaliUrethane LHM @ 650gm/sqm or equivalent)as per manufacturs instructions. Extend waterproofing treatment up to 200 mm and terminate into groov on the parapet wall.(iv) Protect the applied liquid membrane by sprinkling sand @ 200gm/Sqm over the final coating when the surface is still tacky to facilitate plastering, and including 25 mm thick plastering in CM 1:3 with admixture and WPC.Note No-1:- treatment shall be done though authorised representative of manufacture's instructions. |
| 14 | M&L for carrying out water proofing treatment for roofs in the following stages- (i) Taking down existing water proofing treatment and old roof plaster including cleaning roof surface by washing and rubbing etc. and removing the material retrieved to a distance not exceeding 500 m where directed.(ii) First coat of bitumen primer confirming to IS 3384 @0.300 Kg/ Sqm over plastered surafces(iii) Second layer of 3.0 mm thick APP modified polymeric membrane with centre core of Single non woven polyster reinforcement and having weight 3 Kg/ Sqm with mineral gravel finish on top complete laid with blown type bitumen confirming to IS 702-1988 grade 85/25 @ 1.20 Kg/ Sqm complete all as specified and as directed. |
| 15 | M&L for carrying out water proofing treatment for roofs in the following stages- (i) Taking down old existing surface APP membrane water proofing treatment cleaning roof surface by washing and rubbing etc. and removing the material retrieved to a distance not exceeding 500 m where directed.(ii) First coat of bitumen primer confirming to IS 3384 @0.300 Kg/ Sqm over old plastered surafces(iii) Re-surfacing old existing APP membrane over bitumen primer surfaces laid with blown type bitumen confirming to IS 702-1988 grade 85/25 @ 1.20 Kg/ Sqm complete all as specified and as directed. |
| 16 | Supply only integral water proofing liquid ISI marked Make: Pidiproof LW |
| 17 | Dismantling boarding of any description fixed in any position with nails, complete all as specified. |
| 18 | S&F PVC hollow wall lining interlocking type 5-7mm thick plain/ coloured, fitted into the wall with PVC rawal plugs and steel screws including fillets on joints as per manufacturers instruction complete all as specified and directed by Engineer in charge. (Note:- If any minor electricial fittings and fixtures disturbed their-in will be match and fixed as existing.) |
| 19 | S&F Gypsum board 6-8mm thick in ceilling fixed with screw as per manufacturer's instructions, plain/ colour fixed with steel snap grid (powder coated bottom side) with 'T' and 'L' (25mmx30mmx1.00mm thick) section of size 600mm x 600mm placed in ceiling 'L' section fixed to wall with PVC rawal plugs and steel screws @ 600mm centre to center, including provided 5.0 mm dia galvanised bars/ wire suspended @ 1.80 mtr centre to center both sides proper hanging arrangements and maintain levels with adjustable clips, complete all as specified and directed. (Note:- If any minor electricial fittings and fixtures disturbed their-in will be match and fixed as existing). |
| 20 | M&L for plain cement concrete 1:2:4 type B0 using 12.5mm graded stone aggregates as over roof for making good depression/ undulation to make the existing roof surfaces as filling in depression of roof slab/ floor padding/ roof kerbs copings rounded or chamfered on edges coping etc complete all as specified and as directed. |
| 21 | M&L for cement concrete (1:2:4) type B-1 using 20 mm graded stone aggregate as in kerbs or benching etc including necessary form work complete all as specified. |
| 22 | M&L for rendering 15 mm thick in CM 1:6 over stone masonary, concrete surfaces, finished even and smooth (without using extra cement), all as specified and as directed. |
| 23 | M&L for 15 mm thick rendering on stone masonary wall surfaces in CM 1:4 finished fair and even all as specified and as directed. |
| 24 | M&L for 10mm thick rendering in CM 1:3 on ceiling surfaces finished surfaces even and smooth without using extra cement complete all as specified and as directed. |
| 25 | S&F low carbon annealed wire in hexagonal shape 1.0mm diametre chicken wire mesh of size 25mm (distance between the faces of the hexagon), durable twisted woven mesh for mounting on curved and angled surfaces including 15cm lap at junction fixed with nails and properly stapled complete all as specified and as directed. |
| 26 | S&F Powder Coating (minimum thickness of powder coating 50 micron) Anodised aluminium frame for doors,windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified |
| 27 | S&F powder coated of any colour (Thickness or powder coating not less than 50 micron) anodised aluminium door shutters,aluminium section weighing 0.55 kg/m including necessary joining cleats,glazing clips, ruber neoprene packing,handles 2 Nos in each door, hinges,anodised aluminum snap beading screws etc. complete all as specified. |
| 28 | S&F powder coated of any colour (Thickness or powder coating not less than 50 micron) anodised aluminium window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specified |
| 29 | S&F powder coated of any colour (Thickness or powder coating not less than 50 micron)Anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips,rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 no.) complete all as specified |
| 30 | S&F Anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineerin-charge |
| 31 | S&F for glass, ordinary quality, 4.8 mm thick, any size and glazing with aluminium beading in aluminium frame all as specified and as directed. |
| 32 | S&F of galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanised wire staples complete all as specified & as directed. |
| 33 | S&F 12 mm thick prelaminated particle board, interior grade,prelaminated both sides with decorative choice laminations, fixed with screws to timber frame work |
| 34 | S&F mild steel 4 levers Mortice lock, vertical type, size 100 mm suitable for aluminium door complete all as specified. |
| 35 | S&F 140mm overall length of cover plate Floor door stopper of aluminium alloy body and tongue, anodised,with hard drawn steel spring,fixed in floor |
| 36 | S&F of Factory made steel window box type using ERW hollow 'P' section comprising double frame for and including gauged and glazed Skeleton shutter jointed internally with flat iron 40x4mm complete including grill of 8/10mm square bars as directed by Engineer incharge, fixed horizontally @ 10cm c/c, hinges, handle, tower bolts, stops, lugs etc. (with provision of fixing for cooler if required) all as shown on drawing No CEJZ/TD/20 sheet 1/3 to 3/3 fixed in repairs i.e, incl taking down and removal of old steel windows from site or to store complete all as specified and directed. Note:- Guard bar/ grill shall be measured and paid separately under respective item of Sch 'A'. |
| 37 | S&F framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 |
| 38 | S&F of pressed steel framed made out of 1.25mm thick MS sheet, of size 105x60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc, complete all as specified and directed. |
| 39 | S&F of pressed steel framed made out of 1.25mm thick MS sheet, of size 125x60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc, complete all as specified and directed. |
| 40 | M&L for cement concrete (1:3:6) type C-1 using 20 mm graded stone aggregate as in fillings and mass concrete, filling backs of chowkats etc., complete all as specified |
| 41 | S&F 35mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified. |
| 42 | S & F 35mm thick IInd class hard wood glazed and skeleton door/window shutters, open rebated and prepared to receive glass, gauge etc (devided into panels with plain sash bars any numbers) edges of framing plain, chamfered or rounded all as specified under 8.20(a) of SSR Pt-I. |
| 43 | S&F of factory made solid panel PVC door shutters 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing S&F. Make : Rajshree Doors or equivalent as approved by GE. |
| 44 | S&F of solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing. Make : Rajshree Doors or equivalent as approved by GE. |
| 45 | S&F 100 mm Butt hinges, medium weight, cold rolled mild steel, and fixed complete all as specified. |
| 46 | S&F 150 mm long Aluminium anodised,barrel tower bolts of extruded section and fixed complete all as specified. |
| 47 | S&F 150mm long aluminium handles, cast type,anodised |
| 48 | S&F 300 mm long Aluminium alloy, anodised,sliding door bolt with hasp,staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed |
| 49 | Dismantling wrought iron or mild steel work of any description and in any position not otherwise specifically provided for (framed/ unframed work) complete all as specified. |
| 50 | Taking down 15mm bore steel water tubing and connections etc, including cleaning for refixing or removal from site complete all as specifide. |
| 51 | Taking down 20mm bore steel water tubing and connections etc, including cleaning for refixing or removal from site complete all as specifide. |
| 52 | S&F 15mm bore steel water tubing medium grade galvanised with all fittings and fixed complete to walls and ceiling or laid in floor etc complete all as specifide. |
| 53 | S&F 20mm bore steel water tubing medium grade galvanised with all fittings and fixed complete to walls and ceiling or laid in floor etc complete all as specifide. |
| 54 | Refixing 15 mm dia old steel tubing and connections in new or old position (Walls, ceiling,floors, etc.) |
| 55 | Refixing 20 mm dia old steel tubing and connections in new or old position (Walls, ceiling,floors, etc.) |
| 56 | S&F in repair 15mm bore ball valves high pressure of PTMT with epoxy coated aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. (minimum weight for 25mm ball valves-455gms) fixed in repairs i.e., incl taking down and removal of old unserviceable float valves complete all as specified and as directed. |
| 57 | S&F in repair 20mm bore ball valves high pressure of PTMT with epoxy coated aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. (minimum weight for 25mm ball valves-455gms) fixed in repairs i.e., incl taking down and removal of old unserviceable float valves complete all as specified and as directed. |
| 58 | S&F in repair 15mm nipple suitable for HDPE water tank. (Minimum weight 15 mm-38gms/20mm-45gms /25mm- 65gms) |
| 59 | S&F in repair 20mm nipple suitable for HDPE water tank. (Minimum weight 15 mm-38gms/20mm-45gms /25mm- 65gms) |
| 60 | Disconnecting existing tanks, exc 250 Ltr but n.exc 500 ltr and setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position. (Cleaning repairing, etc. measured separately) |
| 61 | Disconnecting existing tanks, exc 500 Ltr but n.exc 1000 ltr and setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position. Complete alla specified. |
| 62 | Preparing new or previously untreated surfaces of steel or iron work of any description and girth over 10cm and applying two coats of synthetic enamel paint over a coat of red oxide complete all as specified and as directed. |
| 63 | Preparing new plastered surfaces and M&L for applying chalk whitening/ concrete primer and /or cement base putty as required incl preparing the surfaces smooth by rubbing and / or sandpapering and M&L two coats of Distemper oil Emulsion on new plastered surfaces complete all as specified and as directed. |
| 64 | Preparing new plastered or unplastered surfaces by rubbing and / or sandpapering and M&L two coats of cement base paint on new plastered surfaces complete all as specified and as directed. |
| 65 | Preparation of new plastered surfaces of walls etc. & applying three coats of lime white wash on walls complete all as specified and as directed. |
| 66 | Preparing new or previously untreated surfaces of wood and wood based material of any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over one coat of pink primer complete all as specified and directed. |
| 67 | Taking down anodised aluminium door shutters, side hung or fixed type exc 1.5 sqm and n. exc 4 sqm and refixing in same opening after repairing including necessary jointing cleats, glazing clips, rubber packing, screws etc and with existing anodised aluminium snap beading, screws anodised aluminium fittings such as hinges type B-21, 125mm long anodised section complete including overhauling of floor door spring hydaulically regulated complete all as specified and directed.Note:- Glass pane/particle board paid extra of respective schedule of item but aluminium glass clips/rubber beading and any necessary fitting included of this item) |
| 68 | Supply and fixing in repair Aluminium (Die cast) body Door closer hydraulically regulated designation No 3 universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed complete all as specified and directed |
| 69 | Hacking out old broken glass (any thickness, size, quality or description) from wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads complete all as specified. |
| 70 | S&F 3mm thick sheet glass,ordinary quality and glazing with oil putty in of n exc 0.5 sq. m in each pane complete all as specified. Note:- Glass repalced upto height of 8 Mtr and use of Scaffolding, trestles, ladders, cradles etc necessary for execution of work and all protective measures responsibilty including removal of old broken glass from site where directed by Engr-in Charge is included of this item. |
| 71 | S&F in repair galvanised mild steel wire cloth, 0.63mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks, or galvanised wire staples complete all as specified.Note-Wiremesh cloth replacement for any type of door/window/ventilators with necessary screws,nut bolts/welding shall be inclusive of this item nothing to paid extra on this account. |
| 72 | S&F in repair 300mm mild steel ,ordinary rat tail rod pattern springs including roller and roller plate complete |
| 73 | S&F in repair 4mm dia Plain mild steel wire, galvanised class 3,in fencing including straining and fixing to wood, concrete or steel posts and/or to straining bolts, including securing with and provision of galvanised iron tying wire, galvanised iron staples or steel pins, etc detached work such as for mosquito nets and fixing to straining bolts, hooks, eyes,etc.. as directed (each line of wire to be measured) |
| 74 | M&L drilling hole into stone wall/PCC wall up to any depth for inserting mosquito net wire into hole and fixed to suitable fixing arrangement complete all as specified. |
| 75 | S&F in repair 25mm dia Mild steel rag or lewis bolts, screwed one end, with hexagonal or square nuts and washers, the other end enlarged and jagged or lewised, exc 15cm long but n.exc 30CM long complete all as specified. |
| 76 | S&F in repair stainless steel curtain rods 25mm dia including fixing SS brackets Lattu & side cups /fency type knobs complete complete all as specified and directed |
| 77 | Dismantling timber scantlings 40 sq. cm and over in section, in any position as in framed work complete all as specified. |
| 78 | Dismantling timber scantlings fillets, rails, posts, rafters, purlins, etc. under 40 sq. cm in any position as in framed work section complete all as specified. |
| 79 | S&F Roof trusses (framed), trussed,purlins, crane gantries, rails and fastenings and heavy bracketframing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. |
| 80 | S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws including Dismanteling of plain or corrugated steel sheeting,any gauge, thickness, includingNainital or similar pattern roof coverings as specifiedNote - The contract sum shall be calculated by deducting the amount shown in Credit Schedule attached to this tender, from total amount of Schedule 'A'/BOQ. Please Enable Macros to View BoQ information |