| 1 | Earth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth anddisposal of surplus excavated earth as directed, within a lead of 50 metres: 80%. All kinds of soils and 20% ordinary rock |
| 2 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering , all works upto plinth level ( 1 : 4 : 8) 1 cement 4 coasre sand 8 stone aggregate grade, with 40mm nominal size . |
| 3 | Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts,struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchors blocks, plain window sills, fillets etc upto floor V level, including curing but excluding the cost of centring, shuttering and finishing with .1:5:10 (1 cement : 5 coarse sand : 10 graded brick aggregate 40 mm nominal size ( first floor under floor ) |
| 4 | Filling available excavated earth(excluding rock) in trenches ,plinth,sudes of foundation etc.Layers not exceeding 20 cm in depth,conslidating each deposited layer by ramming and watering lead upto 50m and lift upto 1.5m. |
| 5 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering , all works upto plinth level ( 1 : 3 : 6)1 cement 3 coasre sand 6 stone aggregate grade , with 20mm nominal size . crushed with 20% boulders. |
| 6 | Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and nforcement. All works upto plinth level 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 7 | Reinforced cement concrete work in walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts upto floor five level including curing but excluding cost of centering shuttering, finishing and reinforcement 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal |
| 8 | Providing and laying Reinforced Cement Concrete 1:1.5:3 (1 cement: 1.5 coarse sand: 3 graded stone aggregate 20 mm nominal size) in suspended floors, balconies, landings and staircase having upto 15° slope. excluding cost of centering and shuttering , all work upto floor V level lintel band |
| 9 | Brick work with common burnt clay F.P.S (Non-modular) brick of class designation 75 in foundation and plinth in 1:6 (1 cement : 6 coarse sand) |
| 10 | Extra for brick work in Super structure above plinth level upto floor V level (By manual means) |
| 11 | Reinforcement of RCC work in Plinth band incl straightening, cutting, bending, placing in position and binding all complete. |
| 12 | Centering and shittering including strutting propping etc and removal of form work Foundation footing bases of columns etc |
| 13 | Centering and shittering including strutting propping etc and removal of form work for lintel beam plinth beam girders bressumers and cantilever plinth beam |
| 14 | Centering and shittering including strutting propping etc and removal of form work columns etc piers butments posts and struts RCC Column :- |
| 15 | Cement concrete flooring 1:2:4 (1cement: 2 coarse sand: 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry and curing complete, but excluding the cost of nosing of steps etc. complete. 50 mm thick with 20mm nominal size stone aggregate. . . |
| 16 | Providing and fixing strips in joints of terrazzo/ cement concrete floors glass strips 40 mm wide and 4 mm thick |
| 17 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1cement :4 coarse sand) including grouting the joints with white cement and matching pigments etc. completeSize of tile 600x600 mm |
| 18 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % andconforming to I.S. 15622, of approved make, in all colours and shades, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), including grouting the joint with white cement and matching pigments etc. complete.size of tile 500x500 mm |
| 19 | Centering and shuttering incl. struting, proping ,etc.and removal of form work for suspended floors,roofing ,landings,balconies and access platform |
| 20 | 15 mm cement plaster on the rough side of single or half brick wall of mix 1:6 ( 1 cement : 6 fine sand ) |
| 21 | 12 mm cement plaster on wall of mix 1:6 ( 1 cement 6 fine sand ) |
| 22 | 6mm cement plaster to ceiling of mix 1 : 3 (1 cement: 3 fine sand) |
| 23 | Providing wood work in frames of doors, windowclerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length (hold fast lugs or with dash asteners shall be paid for separately): Sal wood |
| 24 | Providing and fixing paneled or glazed shutters for doors and windows and clestory windows using 10 kg /sqm (4mm thick) float glass panes including ISI marked black enameled M.S. butt hinges bright finished of requried size with necessary screws, (35mm thick of 2nd class deodar wood). |
| 25 | Providing and fixing 35 mm thick wire gauze shutters using galvanised M.S. wire gauze of average width for aperture 1.4 mm in both directoin with wire of dia. 0.63 mm for doors, windows and clerestory windows with hinges and necessary screws : Second class deodar wood. |
| 26 | Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows including lSI marked M.S. pressed Butt hinges bright finished of required size with necessary screws excluding panelling which will be paid for separately,al! complete as per direction of engineer- in charge. Second class deodar wood |
| 27 | Providing and fixing flat pressed 3 layer particle board medium density exterior grade (Grade I) or graded wood particle board IS : 3087 marked to frame, backing or studding with screws etc. complete (Frames, backing or studding to be paid separately) : 12 mm thick |
| 28 | Strctural steel work welded in built up sections 40 x 40 x 6 mm, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 29 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc including priming coat with approved steel primer all complete.10mm sq bar |
| 30 | Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block 30x10x15 cm 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). 52 nos |
| 31 | Applying priming coat with ready mixed pink or grey primer of approved brand and manufactures on wood work (hard and soft wood) |
| 32 | Painting of doors and windows with ready mixed synthetic enamel paint of approved brand and manufacturers in all shades (two or more coats) on new work |
| 33 | Making plinth protection 50mm thick with cement concrete ( 1 : 3 : 6) 1 cement : 3 Coarse sand: 6 stone aggregate) 20 mm nominal size f stone aggregate over 75 mm bed of dry brick ballast , 40 mm nominal size of well rammed and consolidated and grouted with fine sand including finishing the top smooth. |
| 34 | Providing and laying in position cement concrete of specified grade including curing butexcluding the cost of centring and shuttering. All work upto plinth level with :1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)Rooms |
| 35 | Providing and applying white cement based putty of specified thickness, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 1mm thick |
| 36 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade on New work (two or more coats) over and including priming coat with water thinnable cement primer |
| 37 | FInishing walls with acrylic smooth exterior paint of required shade on New work (Two or more coats applied @ 1.67 liter/10sqm over and including priming coat of exterior primer applied @ 2.20kg/10sqm) |
| 38 | Providing and Fxing aluminium tower bolt ISI marked anodized (anodic coating not less than grade AC as per IS 1868) transparent or dyed to required colouur or shade with necessary screws etc. complete |
| 39 | Providing and Fxing aluminium handle ISI marked anodized (anodic coating not less than grade AC as per IS 1868)transparent or dyed to required colouur or shade with necessary screws etc. complete |
| 40 | Providing and Fxing aluminium handle ISI marked anodized (anodic coating not less than grade AC as per IS 1868)transparent or dyed to required colouur or shade with necessary screws etc. complete 125 mm qty 6 nos |
| 41 | Providing and fixing lSI marked oxidised M.S. sliding door bolts with nuts and screws etc. complet.e 300x16 mm Qty =3 |
| 42 | Carriage of Sand by mechanical transport including loading , unloading & stacking complete lead upto 95 km |
| 43 | Carriage of stone aggregate below 40 mm thick by mechanical transport including loading, unloading & stacking complete lead upto 25 km av |
| 44 | Carriage of bricks by mechanical transport including loading, unloading & stacking complete lead upto 110 av. |
| 45 | Wiring for light point/ fan point/exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit, with modular switch, modular plate, suitable Gl box and earthing the point with 15 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc, as required. Group-A |
| 46 | Wiring for light/ power plug with 2X4 sq. mm FRLS/HFFR Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 47 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 48 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor single core cable in the existing surface/recessed steel/PVC condu as required. 1 x 1.5 sqm |
| 49 | Supplying and fixing following modular switch/ socket on the existing modula plate & switch box including connections but excluding modular plate etc. as required5/6 A Switch |
| 50 | 3 pin 5/6 socket outllet |
| 51 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 52 | Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required |
| 53 | Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings). |
| 54 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, carth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)12 way, double door |
| 55 | Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISI marked 15 8828(1996)/conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum, energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm..conductor line load reversibility, IP 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000. for 80 A & above rating including making connections, testing etc., as required. OEM shall have submit NABL/CPRI/ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge.Single Polw 6/10/16/32 Amp. |
| 56 | SPN 63 Amp |
| 57 | Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS: 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85% Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection, THD <10%, P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5%), life time (LED, Driver & electrical circuitary), of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends, CCT 3000°K/4000°K/5700°K/6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate (T.C.). Manufactures, Word Mark/Name Engraved/Embossing/ Screen printing on housing complete in all respect i/e connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output, LM79 & LM80 Test report from NABIL. lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). CRCA Sheet Body (Thickness≥ 0.50 mm) 18/22 watt 4 feet LED Batten light (System lumen efficacy ≥105 <120 lm/Watt |
| 58 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 59 | Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal (Aluminum alloy) blades, 30 cm long down rod, 2 nos, canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS: 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise 75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Ceiling Fan compliant to 15 374:2019 fan Supply, earthing etc. complete as req1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) |
| 60 | Supplying & laying of PVC insulated and PVC sheathed/XLPE Aluminium power cable of 1.1 KV grade of following size on surfaces/ direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. (Armoured cable)16 sqmm 2 core Please Enable Macros to View BoQ information |