| 1 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. |
| 2 | 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 3 | Centering and shuttering including strutting, propping etc. and removal of form forFoundations, footings, bases of columns, etc. for mass concrete |
| 4 | Centring Columns, Pillars, Piers, Abutments, Posts and Struts |
| 5 | Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 6 | Centring Suspended floors, roofs, landings, balconies and access platform |
| 7 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources): |
| 8 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 9 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 10 | Brick work with common burnt clay machine moulded perforated bricks of class designation 12.5 conforming to IS: 2222 in superstructure above plinth level up to floor five level in cement mortar 1:6 (1 cement : 6 coarse sand) :With F.P.S.(non modular) bricks |
| 11 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 12 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. (Cold twisted bars ) |
| 13 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works |
| 14 | Providing and fixing 1 mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners,all necessary fittings complete, including applying a priming coat of approved steel primer.Using flats 30x6 mm for diagonal braces and central cross piece |
| 15 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with :5.5 mm thick glass panels |
| 16 | Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing. |
| 17 | Supplying and filling in plinth with sand under floors, including watering,ramming, consolidating and dressing complete. |
| 18 | 52 mm thick Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.40 mm thick with 20 mm nominal size stone aggregate |
| 19 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. |
| 20 | 12mm thick plaster with 1:6 cement & F/sand of 1.25 FM minimum thickness not to be less than 10 mm I/C supply of all materials labour and T & P etc required for proper completion of work. |
| 21 | 12mm thick Rough surface plaster with 1:6 cement & F/sand of 1.25 FM minimum thickness not to be less than 10 mm I/C supply of all materials labour and T & P etc required for proper completion of work. |
| 22 | Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement. 12 mm cement plaster |
| 23 | Forming groove of uniform size in the top layer of washed stone grit plaster as per approved pattern using wooden battens, nailed to the under layer, including removal of wooden battens, repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge :15 mm wide and 15 mm deep groove |
| 24 | Applying two coat Putty |
| 25 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour :New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre |
| 26 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade:New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) |
| 27 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work |
| 28 | Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying: (a) after surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound@ 0.253 kg/sqm. |
| 29 | 1015X.767=778.51 |
| 30 | 5/6 amps switch |
| 31 | 15/16 A switch |
| 32 | 3 pin 5/6 A socket outlet |
| 33 | 6 pin 15/16 A socket outlet |
| 34 | 150 mm X 75 mm X 60 mm deep |
| 35 | 150 mm X 150 mm X 60 mm deep |
| 36 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 37 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 38 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 39 | 2 X 10 sq. mm + 1 X 6 sq. mm earth wire |
| 40 | 8 way , Double door |
| 41 | Single pole |
| 42 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 43 | Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required. |
| 44 | Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required. |
| 45 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. |
| 46 | 40 watt |
| 47 | Internal danitary & water supply |
| 48 | Providing and fixing chlorinated polyvinyl chloride (CPVC) pipes having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.00m spacing. The including jointing of pipes and with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in charge. Concealed work, including cutting chases and making good the walls etc.S.I. No.18.8 20 mm dia |
| 49 | Providing and fixing chlorinated polyvinyl chloride (CPVC) pipes having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.00m spacing. The including jointing of pipes and with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in charge. Concealed work, including cutting chases and making good the walls etc.S.I. No.18.8 32 mm dia |
| 50 | Providing and placing on terrace (at all f;oor levels) Polyethylene water storage tank, IS:12701 marked, wih civer and suitable locking arrangement and over flow pipes but without fittings and the base support for tank. S.I. No.18.48 |
| 51 | Providing and fixing waterbcloset squatting pan (Indian type WC Pan) with 100mm sand cast iron P or S trap . 10 litre low level white PVC flushing cistern, including flush pipe, with manually controlled device (handle lever) conformimng to IS :7231 with all fittings and fixturescomplete including cutting and making good the walls and floors whereever required.White Vitreous China Orissa Pattern WC pan of Size 580x440 mm with integral type foot rests .s.I. No-17.1.1 |
| 52 | Supply and fixing of 75 mm dia pvc vent pipe including all complite. . |
| 53 | Supply and fixing of 110 mm dia pvc sewer line I/C all material labour T&P proper complition to the work . |
| 54 | Providing and fixing C.P. Brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms. S.I. No. W/S 18.50 |
| 55 | construction of sock pit |
| 56 | Earth work in excavation over areas including disposal of excavated earth, lead upto 50m, disposed earth to be levelled and neatly dressed. |
| 57 | In all kind of soil upto 1.5m depth |
| 58 | In all kind of soil upto 1.5m to 3.0m. depth |
| 59 | Providing and laying of cement concrete in base excluding the cost of centring and shuttering by 1:2:4 (1 cement : 2 coarse sand : 4 gradded stone aggregae 20mm nominal size) |
| 60 | Brick work with brick of class designation 150 in foundation and plinth in cement mortar (1 cement : 4 coarse sand) |
| 61 | Reinforcement cement concrete work in RCC culvert slab with 1:1.5:3 (1 cement : 1.5 coarse sand and 3 gradded stone aggregate of 20 mm nominal size) including centering and shuttering and reinforcement. |
| 62 | TMT Fe-500 or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level. |
| 63 | 15 mm cement plaster on plinth of mix : 1:4 (1 cement: 4 coarse sand). F.M.-2.25 |
| 64 | Providing M.S. foot rest including fixing with 20x20x10 cm. cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 gradded aggregate of nominal size 20mm ) as per standard design with 20x20mm sq bars. |
| 65 | Providing and fixing C.I. tee at the inlet and outlet of septic tank. |
| 66 | Providing & fixing of 75mm dia cast iron terminal guard. |
| 67 | Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality. |
| 68 | M.D. -2.5- Circular shape 450mm internal diameter |
| 69 | Submersible |
| 70 | 150 mm dia |
| 71 | 100 mm nominal size dia |
| 72 | Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. |
| 73 | 100 mm nominal size dia |
| 74 | Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by \\"V\\" notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tube well, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge.. |
| 75 | 100 mm dia |
| 76 | 100 mm dia |
| 77 | 100 mm dia |
| 78 | Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. |
| 79 | 32 mm dia nominal bore |
| 80 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 4 x 2.5 sq. mm |
| 81 | Supply of submersible pump of make KSB (Cora) for 200 lit/min discharge at 50 meter head with control panel, support wire etc complete for installation in bore well of min 110 mm inner dia preferably more and having under noted specifications. (1.5 H.P.Pump ) |
| 82 | Supply and fixing of Starter Please Enable Macros to View BoQ information |