| 1 | M&L for 9mm thick prelaminated particle board medium interior grade, prelaminated one side with decorated choice lamination & other side balancing white lamination fixed with screws to timber frame work as in wall panelling, shelves/boarding including Dismantlng complete all as specified and as directed. |
| 2 | M&L for 9mm thick prelaminated particle board medium interior grade, prelaminated one side with decorated choice lamination & other side balancing white lamination fixed with screws to timber frame work as in ceiling, shelves/boarding including Dismantlng complete all as specified and as directed. |
| 3 | M&L for 2nd class soft wood clean sawn as in battens for grids of ceiling & lining fixed with nails exc 13 sqcm and n exc 25 sqcm in section including Dismantlng .complete all as specified and as directed. |
| 4 | M&L for 2nd class soft wood clean sawn as in beeding for edges of Ceiling ,lining ,or wooden flooring work fixed with nails exc 6 sqcm and n exc 13 sqcm in section including Dismantlng complete all as specified and as directed. |
| 5 | M&L for covered fillets of standard hard board not less than 6mm thick and up to 40mm wide and fixing with screws including Dismantlng complete all as specified and as directed |
| 6 | Dismantling floor, hearth or wall tiling including wall cement mortar, bedding (But not backing ) and rubbish of premises complete all as directed. |
| 7 | M&L Non-Skid ceramic Coloured Tiles 7 to 8mm thick(squre/rectanglar) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors over 15 mm screed bed or bedding layers in cement mortar 1:4 Set and Jointed in neat Cement Slurry and Pointed in Colour Cement to match, complete all as specified and as directed. |
| 8 | Demolition of cement concrete in ground floor and pavings n'exc 15cm thick below or above ground level complete all as specified and as directed. |
| 9 | M&L for 25 mm thick PCC 1:2:4 type B1 using 20mm graded stone aggregate as in sub base of floor complete all as directed by Engr-in-charge. |
| 10 | Demolition of cement concrete in any description and any position not otherwise specifically provided for, complete all as specified and as directed. |
| 11 | M & L Cement concrete work in pavement/ hard standing of flexural strenth 40 kg/per square centimetre in field using not less than 400 kg of cement per cubic metre , thickness of concrete 25 cm or less specified and directed by Engr-in-Charge. |
| 12 | Supply only metalic floor harderner (300gm/Sqm), complete all as specified. |
| 13 | M & L Forming 12mm thick Expansion joints filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound, Grade 'A' for 150mm thick concrete .complete all as specified and as directed by Engr-in-Charge.Note- Grooves will be cut using groove cutting machine only. |
| 14 | M&L forming contraction (Dummy) joints 65mm deep X 10mm wide , filled with sealing compound Grade 'A' complete all as specified and as directed by Engr-in-Charge.Note- Grooves/joints will be cut using groove cutting machine only. |
| 15 | Taking down shutters of any description area exceeding 1 Sqm and not exceeding 2 Sqm each complete all as directed by Engr-in-charge. |
| 16 | S&F Powder coated (minimum thickness of powder coating 50 micron) anodised aluminium door shutters, aluminium section weighing 0.55 Kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, anodised aluminium snap beading screws etc. complete all as specified |
| 17 | S&F mild steel butt hinges, medium weight cold rolled 100mm size complete all as specified and as directed. |
| 18 | S&F 150mm long aluminium anodized, barrel tower bolt of extruded section complete all as specified and as directed. |
| 19 | S&F 150mm size extruded aluminium alloy handles, fabricated type, anodized complete all as specified and as directed. |
| 20 | S&F in 250mm long aluminium alloy, anodized, sliding door bolt with hasp & staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolt and sliding bolts of extruded section or cast aluminium alloy fixed complete all as specified and as directed |
| 21 | M&L sheet glass 4.8mm thick ordinalry quality and glazing with oil putty or wooden beads in square exc 0.50 sqm in each pane complete all as specified and as directed. |
| 22 | Hacking out old broken glass (any thick ness, size, quality or description) from wooden panes or stone, concrete or brick surrounds, glazed with oil putty or fixed with beads complete all as specified and as directed . |
| 23 | Dismantling plain or corrugated steel /fibre sheeting any guage thickness including nanital or similar pattern complete all as specified and as directed, |
| 24 | S&F 0.63mm thick Galvanised corrugated mild steel sheeting with two corrugations side lap, fixed with coach screws and washers in roofs walls etc. with grade of zine coating 275, complete all as specified and as directed. |
| 25 | Ditto all as item No 24 above but except sheeting, complete all as specified and as directed. |
| 26 | S&F Fibre glass reinforced translucent plain sheeting 2mm thick with two corrugations side lap fixed with coach screw and washer in roof ,wall etc complete all as specified and as directed. |
| 27 | S&F Pre painted galvalume aluminium zinc coating GI based Plain steel sheet 0.50mm thick as in ridges , valley gutters drip etc of an colour having tensile strength of 550 Mps as in roof covering /cladding to wall fixed with self tapping screws as specified |
| 28 | S&F Pre painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mps as in roof covering /cladding to wall fixed with self tapping screws as specified |
| 29 | Dismantling wrought iron or mild steel work of any description not otherwise provided for angle iron or flat iron as in post and guard bars or grating, complete all as specified and as directed. |
| 30 | S&F MS Rolled sections in main and cross beams,hip and jack rafters ;purlins where connected to common rafters running rails and guids for sliding doors ;fixed with angle cleats or other connecting plates and similar work confirming to Fe-290, Gde-E-165 complete all as specified and as directed. |
| 31 | M&L preparation of new untreated steel surfaces exc. 10 cm width/girth and applying two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed. |
| 32 | M&L for preperation of existing treatment on steel surfaces of any description and applying two coat of synthetic enamel paint (galvanisatin should be removed if required) ,complete all as specified and as directed. |
| 33 | Demolition of bricks (laid flat or on edge) or interlocking tiles in floors, channels, kerbes, aprons, etc laid dry of laid dry and pointed. |
| 34 | M&L sand filling under floors in foundations and for laying Interlocking paver blocks including watering and consolidation complete all as specified and as directed by Engr-in-Charge.. |
| 35 | M & L for 100mm PCC 1:4:8 type D-2 using 40mm graded crushed stone aggregate as in sub base of floor,complete all as specified and as directed. |
| 36 | M&L machine pressed precast concrete interlocking paver block any shape and size polished with grey cement and pigment confirming to IS 15658-2006 of 60 mm thickiness M-35 grade complete all as specified and as directed by Engr-in-Charge.. |
| 37 | S&F in repair 19mm dia mild steel, chromium plated curtain rods, with brackets, end bulbs all as specified and as directed by Engr-in-charge. |
| 38 | S&F in repair 600x450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial ply wood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed by Engr-in-Charge. |
| 39 | S&F in repair aluminium (Die cast) body door closer hydraulically dessignation No 3 universal type suitable for door shutter of 851 to1000mm in width and weight 61 to 80 kg all as specified and directed |
| 40 | Taking down carefully copper/aluminium point wiring (light, fan, socket and power point) complete fittings such as switches, ceiling rose, regulators, socket etc and removing material from site and making good disturbed surfaces of walls, floors/ceiling to match the existing surface all as spfd and directed by Engr-in-Charge. |
| 41 | Taking down of submain wiring surface of wall, floores / ceiling and match the existing complete all as specified and directed. |
| 42 | Point wiring complete with 1.5Sq.mm nominal area of copper conductor multi stranded PVC insulated and unsheathed 1100 volts cable drawn through & including PVC Casing & caping with standard accessories such as elbows, tees, junctions etc. and PVC moulded terminal box with top cover of including PVC insulated unsheathed solid 1.5Sqmm copper conductor cable as continuous earth lead all as specified and directed for the followings:- |
| 43 | One light/exhaust fan point controlled by one one way switch |
| 44 | One switch socket outlet 6 Amps, 230 volts point on Same board |
| 45 | One switch socket outlet 6 Amps, 230 volts point on independent board |
| 46 | All as item No 42 above, but using cables 2.5 Sq mm size . |
| 47 | All as item No 42 above, but using cables 4 Sq mm size. |
| 48 | Supply and replacement of lamp holder insulated body with back plate. |
| 49 | Supply and fix |
| 50 | Supply and fix of Socket outlet 5 pin 6 Amps flush type.230 volts complete all as directed. |
| 51 | Supply and fix switch Socket out let two in one 5 pin 6 Amps flush type.230 volts complete all as directed. |
| 52 | Supply and fix switch Socket combination out let multi purpose 5 pin 6 Amps and 16Amps 230 volts complete all as directed. |
| 53 | Supply and fix Ceiling rose, surface Bakelite three terminals complete all as directed. |
| 54 | Supply and fix in replacement of sheet metal enclosure for DBs double door when MCB's to be used tripple pole & neutral 415 Volts 4 Ways all as specified and directed by Engr-in-Charge. |
| 55 | Supply and fix in replacement of sheet metal enclosure for DBs double door when MCB's to be used single pole & neutral 240 Volts 8 Ways all as specified and directed by Engr-in-Charge. |
| 56 | Supply and fixing, TPN 100 Amp, 415V 10KA 'C' curve miniature circuit breaker (MCB) all as specified and directed by Engr-in-Charge. |
| 57 | Supply and fix in replacement of MCB SPN 63 Amp 240 Volts AC ISI marked all as specified and directed by Engr-in-Charge. |
| 58 | Supply and fix in replacement of MCB SP 6-32 Amps. 240 Volts 50 HZ complete all as directed. |
| 59 | Supply and fix in replacement submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/recessed as required in PVC casing Caping wire size 2x10.0 sq. mm + 1x10.0 sq. mm earth wire complete all as specified and directed. |
| 60 | Supply and fixing LED flood light 100 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and directed. |
| 61 | Supply and fix in replacement LED luminaire 600mm x 600 mm, 35/36 watt,220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cable of suitable size complete all as specified and directed |
| 62 | Supply and Fixing only in Replacement LED light fitting 1X20 W, 220 V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. |
| 63 | Supply, fixing, connecting and testing in replacement LED security light fitting 35 watt, 230 volt, AC outdoor type with high pressure die cast aluminium housing and heat resistant complete with driver, lamp and bracket with impact and corrossion resistant incl thermal management in multiple optics complete with IP65/66 protection complete all as specified and directed. Please Enable Macros to View BoQ information |
| 64 | Supply, fixing, connecting and testing in replacement LED security light fitting 35 watt, 230 volt, AC outdoor type with high pressure die cast aluminium housing and heat resistant complete with driver, lamp and bracket with impact and corrossion resistant incl thermal management in multiple optics complete with IP65/66 protection complete all as specified and directed. Please Enable Macros to View BoQ information |